首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 806 毫秒
1.
The purpose of this study was to assess neuromuscular activation of the three superficial portions of the quadriceps femoris muscles during linearly increasing isometric contraction intensities. Thirty healthy volunteers were assessed for isometric electromyographic (EMG) activity of the vastus medialis (VM), vastus lateralis (VL), and rectus femoris (RF) muscles with the knee at 60 degrees of flexion. For 5 s, subjects performed isometric contractions equivalent to 10%, 20%, 30%, 40%, 50%, 60%, 70%, 80%, and 90% of the average of three maximal voluntary contractions (MVC), in random order. Full-wave rectified and integrated EMG signals over the middle 3 s of each contraction were expressed as a percentage of the activity recorded during the three averaged MVCs. One sample t-tests and 95% confidence intervals were calculated at each relative torque level. A two-factor analysis of variance (muscle by intensity) with repeated measures was performed to evaluate parallel activation across the intensity levels. Activation linearity was assessed via regression analysis for each muscle. VM activation was shown to be significantly lower than expected at 20-70% MVC. VL and RF activations were significantly higher than expected at 10% MVC, and RF EMG was less than expected at 40-70% MVC. EMG of VM was shown to increase significantly more than VL and RF from 80% to 90% MVC. Significant linear and quadratic relations were also demonstrated for all three muscles. Parallel activation of the superficial quadriceps muscles occurred from low to moderate intensities, whereas convergence was noted at near maximal intensities.  相似文献   

2.
The purpose of this study was to determine mechanomyographic (MMG) and electromyographic (EMG) responses of the superficial quadriceps muscles during repeated isokinetic contractions in order to provide information about motor control strategies during such activity, and to assess uniformity in mechanical activity (MMG) between the investigated muscles. Ten adults performed 50 maximal concentric muscle contractions at three randomly selected contraction velocities (60, 180, and 300 degrees.s(-1)) on different days. Surface electrodes and an MMG sensor were placed on the vastus lateralis (VL), rectus femoris (RF), and vastus medialis (VM). EMG and MMG amplitude and peak torque (PT) were calculated for each contraction, normalized, and averaged across all subjects. The results demonstrated that MMG amplitude more closely tracked the fatigue-induced decline in torque production at each velocity than did EMG amplitude. This indicates that MMG amplitude may be useful for estimating force production during fatiguing dynamic contractions when a direct measure is not available, such as during certain rehabilitative exercises. MMG amplitude responses of the VL, RF, and VM were not uniform for each velocity or across velocities, indicating that it may be possible to detect the individual contribution of each muscle to force production during repeated dynamic contractions. Therefore, MMG amplitude may be clinically useful for detecting abnormal force contributions of individual muscles during dynamic contractions, and determining whether various treatments are successful at correcting such abnormalities.  相似文献   

3.
The purpose of this study was to determine the velocity-related patterns for mechanomyographic (MMG) amplitude, electromyographic (EMG) amplitude, mean power output (MP), and peak torque (PT) of the superficial muscles of the quadriceps femoris (vastus lateralis [VL], rectus femoris [RF], and vastus medialis [VM]) during maximal, concentric, isokinetic leg extensions. Twelve adult women (mean +/- SD: 22 +/- 3 years of age) performed such leg extensions at velocities of 60 degrees, 120 degrees, 180 degrees, 240 degrees, and 300 degrees /s on a Cybex 6000 dynamometer. PT decreased (P < 0.05) across velocity to 240 degrees /s. MP and MMG amplitude for each muscle (VL, RF, and VM) increased (P < 0.05) with velocity to 240 degrees /s and then plateaued. EMG amplitude increased (P < 0.05) to 240°/s for the VL, remained unchanged across velocity (P > 0.05) for the RF, and increased (P < 0.05) to 300 degrees /s for the VM. The results indicated close similarities between the velocity-related patterns for MMG amplitude and MP, but dissociations among EMG amplitude, MMG amplitude, and PT. These findings support the recent hypothesis that MMG amplitude is more closely related to MP than PT during maximal, concentric, isokinetic muscle actions and, therefore, may be useful for monitoring training-induced changes in muscle power.  相似文献   

4.
The purpose of this study was to investigate the behavior of electromyographical (EMG) and vibromyographical (VMG) signals in the time and frequency domains during a fatigue protocol. EMG and VMG records were obtained from the rectus femoris (RF) and vastus lateralis (VL) muscles of 11 adult male subjects during sustained, isometric knee extensor contractions performed at 70% of maximal voluntary contraction (MVC). The average median frequencies of the power density spectra decreased during the fatigue protocol for the EMG (from 73 to 54 Hz for RF, and from 75 to 57 Hz for VL) and the VMG signals (from 40 to 19 Hz for RF, and from 25 to 12 Hz for VL). Raw EMG signals remained the same qualitatively throughout the fatigue protocol, whereas corresponding VMG records appeared to become “smoother.” The results of this study indicate that the pronounced decrease in the high-frequency content of the VMG signal may be observed in the time domain as a “smoothing” of the signal, and thus, that the raw VMG records (which may be displayed readily online) can be used to assess qualitatively the onset and progression of muscular fatigue. © 1994 John Wiley & Sons, Inc.  相似文献   

5.
The purpose of this investigation was to examine the linearity and reliability of the mechanomyographic (MMG) amplitude versus dynamic torque relationships for the vastus lateralis (VL), rectus femoris (RF), and vastus medialis (VM) muscles. Nine healthy men and 11 healthy women performed submaximal to maximal, concentric, isokinetic muscle actions of the leg extensors at 30° s?1 on two occasions. Surface MMG signals were detected from the VL, RF, and VM of the dominant thigh during both trials. The ranges of the coefficients of determination for the MMG amplitude versus dynamic torque relationships were 0.01–0.94 for the VL, 0.01–0.84 for the RF, and 0.19–0.96 for the VM. The intraclass correlation coefficients for the linear MMG amplitude versus torque slope coefficients were 0.823 (VL), 0.792 (RF), and 0.927 (VM). These results indicate that, when analyzed for individual subjects, the MMG amplitude versus dynamic torque relationships demonstrated inconsistent linearity. When using MMG in the clinical setting, dynamic muscle actions of the superficial quadriceps femoris muscles do not appear to be appropriate for assessing changes in muscle function during strength training. Muscle Nerve, 2009  相似文献   

6.
The consequences of baclofen intake on voluntary motor behaviors remain unclear. We studied the effects of single oral doses of baclofen on voluntary, isometric knee extension torques and surface and single motor unit (MU) electromyographic (EMG) activity from the vastus lateralis in 11 individuals without neurological injury. Examination of submaximal to maximal contractions of varying duration performed pre- and post-baclofen ingestion revealed significant decreases in maximal knee torques and EMG magnitude, accompanied by an increase in slope of the torque-EMG relation. A decreased slope of the torque-MU firing rate relation was also demonstrated post-baclofen, but without changes in minimal firing rates or recruitment forces. During sustained contractions at < or =25% of maximal voluntary torque elicited after baclofen ingestion, increased EMG activity was observed without significant differences in MU firing rates. Our results demonstrate a clear reduction in the maximal torque-generating ability following baclofen. Specific changes in MU firing patterns indicate that weakness may be due partly to reduced motoneuronal excitability, although use of MU discharge patterns to assess these effects is limited in its sensitivity.  相似文献   

7.
The purpose of this study was to compare the electromyographic (EMG) amplitude and mean power frequency (MPF) versus power output relationships for the three superficial quadriceps muscles during incremental cycle (CE) and knee‐extensor (KE) ergometry in the same subjects. Eight men performed incremental CE and KE tests to exhaustion. Surface EMG signals were recorded simultaneously from the vastus lateralis (VL), rectus femoris (RF), and vastus medialis (VM). Polynomial regression analyses on a subject‐by‐subject basis indicated that the relationship between EMG amplitude versus power output was best‐fit with either a linear, quadratic, or cubic model for CE, whereas the relationship was best‐fit with a linear model for all subjects for the KE test. No consistent relationship was found for EMG MPF within subjects and between muscle groups for CE or KE. Compared with CE, however, the EMG amplitude during KE exercise was, on average, approximately 87% and 30% higher for the RF and VM muscles, respectively. These results suggest that KE exercise may be a better mode of examining EMG amplitude in the quadriceps muscle during incremental exercise than traditional CE. Muscle Nerve, 2009  相似文献   

8.
The purpose of this study was to use a wavelet analysis designed specifically for surface mechanomyographic (MMG) signals to examine the MMG responses of the vastus lateralis (VL), rectus femoris (RF), and vastus medialis (VM) muscles. Fifteen healthy men [age (mean ± SD): 26.4 ± 6.1 years] volunteered to perform isometric muscle actions of the dominant leg extensors at 20%, 40%, 60%, 80%, and 100% of the maximum voluntary contraction (MVC). During each muscle action, surface MMG signals were detected from the VL, RF, and VM and processed with the MMG wavelet analysis. The results show that, for the VL and VM muscles, there was compression of the total MMG intensity spectra toward low frequencies for most force levels above 20% MVC. For the RF, however, the peak of the total MMG intensity spectrum occurred at approximately 30–40 HZ for all force levels. Because the VL, RF, and VM are all innervated by the femoral nerve, the discrepancies among the three muscles for total MMG intensity in each wavelet band may have been due to differences in architecture, muscle stiffness, and/or intramuscular pressure. Muscle Nerve 39: 355–363, 2009  相似文献   

9.
The purpose of this study was to compare the extent of twitch potentiation (TP) after stimulated or voluntary contractions at identical intensities for the human knee extensor muscles. Isometric knee extensions of 10 s were performed at 20%, 40%, and 60% of maximal voluntary contraction (MVC) torque level, through percutaneous electrical stimulation of the quadriceps at 80 Hz or voluntary contraction. Twitch responses were evoked by stimulating the femoral nerve percutaneously with supramaximal intensity. The extent of TP after the stimulated contraction was greater than that after the voluntary contraction at the 20% MVC torque level, whereas a stimulated contraction induced a smaller extent of TP than did a voluntary contraction at contraction intensities higher than 40% MVC. We suggest that this contraction intensity dependence of differences in TP after stimulated and voluntary isometric conditioning contractions is responsible for differences in the recruitment pattern of motor units during the conditioning contractions.  相似文献   

10.
Introduction: The purpose of this study was to determine the effects of vibration (VIB) on motor unit (MU) behavior of the vastus lateralis (VL) muscle during a 40% maximal voluntary contraction (MVC). Methods: Eleven healthy (age 21.3 ± 2.6 years) individuals participated in the study. Surface electromyography (EMG) data were recorded from the VL during isometric trapezoidal muscle contractions at 40% MVC. Firing events of single MUs and EMG amplitude were reported for the first, middle, and final seconds of a 12‐second steady force segment at 40% MVC. VIB was applied at 55 Hz to the patellar tendon for 15 minutes before and continued throughout the remainder of testing (VIB) or remained off (CON). Results: There were significant increases in MU firing rates during VIB in comparison to CON and no differences in EMG amplitude between VIB and CON. Conclusion: The VIB‐mediated reduction in muscle spindle function altered MU behavior at 40% MVC. Muscle Nerve 55 : 500–507, 2017  相似文献   

11.
Introduction: The purpose of this study was to examine the electromyographic (EMG) spectral characteristics of the quadriceps femoris muscles during tendon tap stretch reflexes. Methods: Sixteen healthy subjects (mean ± SD age = 21.2 ± 2.8 years) performed tendon tap reflexes of the leg extensors as surface EMG signals were detected from the vastus lateralis (VL), rectus femoris (RF), and vastus medialis (VM) muscles of the dominant thigh. All EMG signals were processed with a wavelet analysis, and the resulting spectra were decomposed with nonparametric spectral decomposition. Results: The results showed that the spectra for the VL had significantly more high‐frequency power than those for the RF and VM, with similar spectral shapes for the RF and VM. Conclusions: These findings could be due to differences in the width of the innervation zone, or the fiber type composition of the muscles, although the latter seems to be more likely. Muscle Nerve 52 : 826–831, 2015  相似文献   

12.
OBJECTIVE: The aim of the present study was to investigate the between-days reliability of electromyographic (EMG) measurement of 6 bilateral trunk muscles and also the torque output in 3 planes during isometric right and left axial rotation at different exertion levels. METHODS: Ten healthy subjects performed isometric right and left axial rotation at 100, 70, 50 and 30% maximum voluntary contractions in two testing sessions at least 7 days apart. EMG amplitude and frequency analyses of the recorded surface EMG signals were performed for rectus abdominis, external oblique, internal oblique, latissimus dorsi, iliocostalis lumborum and multifidus bilaterally. The primary torque in the transverse plane and the coupling torques in sagittal and coronal planes were measured. RESULTS: For both EMG amplitude and frequency values, good (intraclass correlation coefficient, ICC=0.75-0.89) to excellent (ICC>/=0.90) reliability was found in the 6 trunk muscles at different exertion levels during axial rotation. The reliability of both maximal isometric axial rotation torque and coupling torques in sagittal and coronal planes were found to be excellent (ICC>/=0.93). CONCLUSIONS: Good to excellent reliability of EMG measures of trunk muscles and torque measurements during isometric axial rotation was demonstrated. This provides further confidence of using EMG and triaxial torque assessment as outcome measures in rehabilitation and in the evaluation of the human performance in the work place.  相似文献   

13.
Time-frequency analysis of the surface electromyographic (EMG) signal is used to assess muscle fiber membrane properties during dynamic contractions. The aim of this study was to compare the direct estimation of average muscle fiber conduction velocity (CV) with instantaneous mean frequency (iMNF) of surface EMG signals in isometric and explosive dynamic contractions. The muscles investigated were the vastus lateralis and medialis of both thighs in 12 male subjects. The isometric contractions were at linearly increasing force (0-100% of the maximal voluntary contraction in 10s). The explosive contractions were performed on a multipurpose ergometer-dynamometer (MED). The subject, sitting on the MED, performed six explosive contractions, separated by 2min rest, by pushing against two force platforms and thrusting himself backwards with the maximum possible speed, while completely extending his legs. The estimated CV significantly increased with force in both the isometric (mean+/-S.D., from 3.24+/-0.34 to 5.12+/-0.31m/s for vastus lateralis and from 3.17+/-0.26 to 5.11+/-0.34m/s for vastus medialis, with force in the range 10-100% of the maximal voluntary contraction level) and explosive contractions (from 4.36+/-0.49 to 5.00+/-0.47m/s for vastus lateralis, and from 4.32+/-0.46 to 4.94+/-0.44m/s for vastus medialis, with force in the range 17.5-100% of maximal thrusting force). Moreover, estimated CV was not significantly different at the maximal force in the two exercises. On the contrary, iMNF, computed from the Choi-Williams time-frequency transform, was significantly lower in the explosive (57.7+/-8.2 and 66.5+/-10.3Hz for vastus laterialis and medialis, respectively) than in the isometric exercises (73.7+/-9.2 and 75.0+/-8.5Hz for vastus laterialis and medialis, respectively) and did not change with force in any of the conditions. It was concluded that EMG spectral features provide different information with respect to average muscle fiber CV in dynamic contractions. Thus, in general, they cannot be used to infer CV changes during the exertion of a dynamic task. A joint analysis of CV and EMG spectral features is necessary in this type of contractions.  相似文献   

14.
Physiological stimuli which increase postural extensor tone also excitability of the crossed extension reflex (CER). We report here that such stimuli increase excitability of the CER recorded from rectus femoris (RF) more than that of vastus medialis (VM). The difference might reflect an important role of the biarticular actions of RF, which is also a weak hip flexor, in stabilizing the hip as well as extending the knee during maintenance of posture.  相似文献   

15.
Introduction: This study determined the between‐session reliability of neuromuscular measurements during explosive isometric contractions, with special consideration of electromyography (EMG) normalization. Methods: Following familiarization, 13 men participated in 3 identical measurement sessions involving maximal and explosive voluntary contractions of the knee extensors, while force and surface EMG were recorded. Root mean square EMG amplitude was normalized to different reference measures: (evoked maximal M‐wave peak‐to‐peak amplitude and area, maximum and sub‐maximum voluntary contractions). Results: Explosive voluntary force measurements were reliable on a group level, whereas within‐subject reliability was low over the initial 50 ms and good from 100 ms onward. Normalization of EMG during explosive voluntary contractions, irrespective of the reference method, did not reduce the within‐subject variability, but it did reduce substantially the variability between‐subject. Conclusions: The high intra‐individual variability of EMG and early phase explosive voluntary force production may limit their use to measuring group as opposed to individual responses to an intervention. Muscle Nerve 46: 566–576, 2012  相似文献   

16.
Introduction: We investigated the effect of contraction intensity [100%, 75%, 50%, and 25% maximum voluntary contraction (MVC)] and movement velocity (50°, 100°, 200°, and 400°/s) on surface electromyography root mean square amplitude (SEMGRMS) and median frequency (SEMGMDF) of rectus femoris (RF), vastus lateralis (VL), and vastus medialis (VM). Methods: SEMGs during knee extension were resolved into their respective frequencies using wavelet transformations. Results: RF, VL, and VM muscles displayed increased SEMGMDF as contraction intensity increased from 25% to 50% MVC and from 75% to 100% MVC, and each muscle displayed its own unique frequency shifting patterns. The SEMGMDF was not influenced by movement velocity. SEMGRMS increased in all 3 muscles as contraction intensity increased and was influenced by movement velocity, with the highest values observed at 400° and 200°/s. Conclusions: We infer that increasing contraction intensity facilitates greater recruitment of fast‐twitch muscle fibers, but there are differing responses in RF, VL, and VM muscles. Muscle Nerve 50 : 844–853, 2014  相似文献   

17.
OBJECTIVE: Accurate neuromuscular control of the patellofemoral joint is important in knee joint mechanics. Strategies to coordinate the vasti muscles, such as motor unit synchronization, may simplify control of patellar tracking. This study investigated motor unit synchronization between vastus medialis (VM) and lateralis (VL). METHODS: Electromyographic (EMG) recordings of single motor unit action potentials (MUAPs) were made from VM and single- and multi-unit recordings were made from VL. Synchronization was quantified from peaks in the cross-correlogram generated from single MUAP pairs in VL and VM. The proportion of motor units in VM with synchronized firing in VL was also quantified from peaks in averages of multiunit VL EMG triggered from the VM MUAP. RESULTS: A high degree of synchronization of motor unit firing between VM and VL was identified. Results were similar for cross-correlation ( approximately 45% of cases) and triggered averages (approximately 41% of cases). CONCLUSIONS: The data suggest that synchronization between VM and VL is higher than expected. Agreement between traditional cross-correlation and triggered averaging methods suggest that this new technique may provide a more clinically viable method to quantify synchronization. SIGNIFICANCE: High synchronization between VM and VL may provide a solution to simplify control of the mechanically unstable patellofemoral joint.  相似文献   

18.
In 10 healthy subjects freely walking along a straightline, the effects of painful sural nerve stimulation, applied in different phases of the step cycle, were investigated on two antagonistic muscles of the ipsilateral lower limb acting on the knee joint: vastus lateralis (VL) and biceps femoris caput breve (BF). A clear-cut modulation in the amplitude (area) of the net reflex responses was consistently observed in both the motor nuclei explored. The extensor muscle, VL, exhibited a long-latency (mean 122 ms) reflex response, which was maximally increased by stimuli applied toward the end of the swing and in the first half of the stance phase of the stride, whereas the response appeared to be gated during the transition from the foot-flat to forefoot-contact phase. A second facilitation period was brought about by stimuli delivered in the early swing. When the response occurred superimposed on the VL locomotor activity, suppression of the ongoing EMG preceded the reflex discharge. In the flexor, BF, the same stimulus elicited a short-latency (mean 57 ms) and a long-latency (mean 132 ms) reflex response. The former was maximal after stimulation around the toe-off phase and the latter was strikingly enhanced in the late swing, where it was preceded by suppression of the background locomotor EMG activity. Responses with intermediate features (latency 70 to 80 ms, duration 90 to 120 ms), probably resulting from the merging of the early and late components, might be evoked in addition, being greatest in the last swing and in the period preceding toe-off. The findings show that in man the reflex pattern evoked by a painful cutaneous stimulus during locomotion is determined by the phase of the step cycle during which the stimulus is delivered. A functional role in maintenance of postural balance during destabilizing withdrawal reactions is conceivable.  相似文献   

19.
This study examined the effects of pulsed shortwave diathermy on intramuscular temperature, surface electromyography (EMG), and mechanomyography (MMG) of the vastus lateralis. Thirty-five men were assigned to diathermy (n = 13), sham-diathermy (n = 12), or control (n = 10) groups. Each subject performed isometric maximal voluntary contractions (MVCs) and incremental ramp contractions (10%-90% MVC) before and after treatment. Torque, intramuscular temperature, EMG, and MMG were recorded. Temperature for the diathermy group increased (P 相似文献   

20.
We investigated the reproducibility of measurements of maximal voluntary torque and maximal voluntary activation using twitch interpolation. On 5 days, each of 5 subjects performed 10 maximal voluntary isometric contractions of their elbow flexors. Single supramaximal stimuli were delivered over biceps brachii at the measured peak torque during each effort, and in the relaxed muscle 5 s later. A voluntary activation score was calculated from the size of twitches evoked by the stimuli (resolution < 0.15 Nm). Although all subjects were able to drive the stimulated elbow flexor muscles maximally in some trials, they did not do so in 75% of all contractions. Maximal voluntary torques did not vary significantly within a subject between sessions. There were consistent differences in the level of maximal voluntary activation between subjects (P < 0.01), but no differences in voluntary activation within an individual across days in 4 of 5 subjects. Failure to drive the stimulated elbow flexor muscles maximally was not associated with inadvertent co-contraction of the antagonist muscles. © 1995 John Wiley & Sons, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号