首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Arterial mycotic pseudoaneurysms are a rare complication of pancreas transplantation. Rupture results in catastrophic hemorrhage with a high risk of mortality. Definitive management is complicated by an extensive arterial defect within a contaminated surgical field. Synthetic vascular grafts often fail due to subsequent graft infection whereas primary repair often results in arterial stenosis. Arterial ligation may be required to prevent exsanguination. A 41-year-old man, type 1 diabetic with associated renal failure, underwent successful simultaneous pancreas and kidney transplantation. He presented, 9 months following transplantation, with life-threatening rectal bleeding secondary to a ruptured mycotic pseudoaneurysm. This was successfully managed with a bovine pericardial patch (BPP) repair of the arterial defect and enteric diversion following graft pancreatectomy. He remains well with no vascular insufficiency 18 months following the procedure. A ruptured mycotic pseudoaneurysm following transplantation carries a significant risk of mortality and represents a surgical challenge as conventional techniques using synthetic materials often fail due to the contaminated field. A BPP offers good handling characteristics, excellent hemostatic properties and a favorable profile of infection risk in comparison with synthetic grafts. This case highlights its use as a treatment for a post-transplantation ruptured mycotic pseudoaneurysm.  相似文献   

2.
A 62-year-old man presented with continuous, persistent backache shortly after completion of antituberculosis medication for tuberculosis (TB) of the spine. Computed tomography scan revealed a pseudoaneurysm involving the infrarenal aorta. He was restarted on anti-TB medication and underwent repair of the pseudoaneurysm with an in situ silver-coated bifurcated Dacron graft. His postoperative recovery was uneventful and he remained well up to 12 months of follow up. To our knowledge, this is the first case in the literature where an in situ silver-impregnated vascular graft has been successfully used in treating a tuberculous pseudoaneurysm.  相似文献   

3.
Abstract Traditional open surgical repair for aortic rupture from a thoracoabdominal pseudoaneurysm is associated with a high morbidity and mortality. The use of advanced intravascular imaging and endovascular techniques permits selection and customizing endoluminal graft components to treat such catastrophic events in high‐risk surgical patients. We report the successful management of a ruptured thoracoabdominal pseudoaneurysm with an endovascular approach.  相似文献   

4.
This paper describes a case of aortic arch pseudoaneurysm treated with stent graft 2 years after aortosubclavian bypass repair of a subclavian artery aneurysm. An 84-year-old man presented with back pain. Two years before, he had had a left subclavian artery aneurysm repaired with aortosubclavian bypass. Upon examination by computed tomography (CT) scan and angiography he was found to have a bovine arch configuration, a 7-centimeter pseudoaneurysm arising from the stump f the native subclavian artery, a patent aortosubclavian bypass, and a left hemothorax. A 37 mm by 10 mm Gore Excluder thoracic graft was introduced into the right femoral artery cutdown and deployed across the arch, excluding the pseudoaneurysm and preserving the brachiocephalic vessels. Follow up CT scan at 1 year shows exclusion of the pseudoaneurysm. The patient continues to do well 1 year after implantation without evidence of endoleak. In the presence of unusual anatomical characteristics, endoluminal stent graft repair can be successfully performed across the aortic arch.  相似文献   

5.
Use of the intraluminal sutureless ringed prosthesis can reduce graft insertion time and avoid difficulties inherent in suturing to friable, diseased aortic tissue. Since 1976 this device has been inserted into the descending thoracic or thoracoabdominal aorta in 42 procedures for aortic dissection and for aneurysmal disease. The operative mortality rate for descending thoracic aortic dissection repair was 14% and that for descending thoracic aortic aneurysm repair was 8%, with an overall mortality rate of 10%. All three of the patients undergoing thoracoabdominal aortic replacement survived. The mean cross-clamp time for sutureless tube graft insertion was 9 minutes. The average blood replacement was 2.4 units/patient. No patient suffered serious neurologic or renal impairment. A single nonfatal case of graft dislodgement occurred after placement. No evidence of hemolysis, pseudoaneurysm formation, graft erosion, graft migration, or anastomotic bleeding was present in any of the remaining patients. Modification of the sutureless intraluminal device to suit the pathologic condition encountered at operation allows rapid repair with a low incidence of anastomotic complication.  相似文献   

6.
A 76-year-old man was admitted to our hospital for investigation of an apparent abdominal aortic aneurysm detected during treatment for epididymitis. A chest X-ray showed miliary shadows in the bilateral lung fields strongly suggestive of tuberculosis. The diameter of the aneurysm increased, and examinations showed impending rupture of a pseudoaneurysm. However, a definitive disease pathogenesis was not obtained before surgery. We performed a subemergency operation, which revealed an infrarenal abdominal pseudoaneurysm caused by tuberculosis. The pseudoaneurysm appeared to have resulted from direct extension of tuberculous lymphadenitis to the aortic wall, which ruptured. We review 24 other cases of tuberculous aortic aneurysms surgically treated in Japan before 2004.  相似文献   

7.
OBJECTIVE: Open surgical repair for infected thoracic aortic pseudoaneurysms carries significant mortality and morbidity. Endovascular stent graft repair has been our preferred approach, although its role remains controversial because persistent infection is always a concern. We aimed to assess the efficacy and durability of endovascular stent graft repair in these patients. METHODS: Between August 2000 and November 2005, seven consecutive patients with eight infected pseudoaneurysms of the thoracic aorta were treated with endovascular stent graft repair. Patients were diagnosed based on a typical appearance of an infected pseudoaneurysm on imaging together with a positive bacteriology culture or clinical evidence of sepsis. The follow-up protocol included regular clinical examination, hematologic tests, and computed tomography scans. RESULTS: There were six men and one woman with a median age of 68 years at operation. Three patients presented with an aortoenteric fistula. The operations were performed in the operating room with the image guidance of a mobile C-arm. Endovascular stent grafts were deployed successfully in all patients, with complete exclusion of the pseudoaneurysms. Intravenous antibiotics were continued for 1 to 6 weeks and followed by lifelong maintenance oral antibiotics. The median hospital stay was 27 days, with no hospital deaths. No paraplegia or other major complications occurred. Two patients with aortoesophageal fistula where the fistula tracts were persistent died during follow-up. The other five patients remained well, with no evidence of graft infection at a median follow-up of 34 months. A significant reduction in the diameter of the pseudoaneurysm (>5 mm) was noted on computed tomography scans after 12 months. CONCLUSION: Endovascular stent graft repair is effective and may be a durable option for infected pseudoaneurysms of the thoracic aorta.  相似文献   

8.
We report a case of a 51-year-old man presenting with pseudoaneurysm associated with a knitted Dacron patch used to repair coarctation of the aorta. At the age of 15 years, he underwent patch angioplasty for coarctation of the aorta. However the computed tomography( CT) scan, taken after 36 years, demonstrated pseudoaneurysm of the thoracic aorta at the anastmotic site. He was treated by endovascular stent graft using Gore-TAG 3115. His postoperative course was uneventful. Follow-up CT scan demonstrated no recurrence of pseudoaneurysm.  相似文献   

9.
Pseudoaneurysm of the thoracic aorta developed in an infant eight months following neonatal catheterization of the umbilical artery. Infection and placement of a stiff polyvinyl chloride catheter in the thoracic aorta appear to be the etiological factors. Preoperative diagnosis was posterior mediastinal tumor, and pseudoaneurysm was not included in the differential. Dacron graft patch angioplasty repair using partial cardiopulmonary bypass was successful. Postoperatively the patient has done well with no pressure gradient. Pseudoaneurysm should be suspected whenever a mediastinal mass appears in children who have had thoracic placement of umbilical artery catheters.  相似文献   

10.
Tuberculous pseudoaneurysm has been reported to be a fatal, but rare complication of tuberculosis. We report a case of a 68-year-old man who underwent successful surgical treatment for a tuberculous pseudoaneurysm of the thoracic aorta with bronchial communication, and review previous reports of patients who also underwent operation for similar lesions, focusing especially on the pathway of infection to the aorta.  相似文献   

11.
A rare complication of dissecting thoracic aortic aneurysms is rupture into a cardiac chamber or great vessel with fistula formation. A case of congestive heart failure caused by a chronic DeBakey type I dissecting aortic aneurysm that ruptured into the pulmonary artery is reported. Surgical repair involved closure of the fistula followed by graft replacement of the ascending aorta and transverse aortic arch. A review of the literature revealed no previous reports describing successful repair of this lesion. A clinical picture consistent with concomitant aortic dissection and biventricular heart failure, especially when a continuous cardiac murmur is present, suggests the diagnosis of an aortopulmonary arterial fistula caused by a ruptured dissecting thoracic aortic aneurysm. Various imaging studies confirm the diagnosis.  相似文献   

12.
We report a 63-year-old female patient developing a pseudoaneurysm three years after patch-plasty of an aneurysm located at the distal thoracic aorta. Redo-operation was performed including total replacement of the descending thoracic aorta with reimplantation of distal intercostal arteries using small-caliber interposition grafts. This case presentation underlines the ineffectiveness of patch repair for the treatment of aortic aneurysms. Furthermore, the surgical technique of reimplantation of intercostal arteries using a separate graft is discussed.  相似文献   

13.
In 2010, an 84-year-old man underwent thoracic endovascular aneurysm repair (TEVAR) for the saccular descending thoracic pseudoaneurysm (DTAA), which was adherent to the pulmonary lobe and thoracic vertebrae. Past medical history comprised twice anti-tuberculous medications for pulmonary tuberculosis and tuberculous vertebral osteomyelitis. The dilated aorta was detected at the time of medication for tuberculous vertebral osteomyelitis 24?years ago. However, he was not indicated for the operation, and he was lost to follow-up until now. The association of tuberculosis bacilli was suspected through clinical course as an origin of DTAA, although the histopathological examination was not performed because of invasion. TEVAR was performed considering: (1) no preoperative ongoing inflammation, (2) no evidence of tuberculosis recurrence, and (3) risk factors, such as pulmonary impairments and high age. Several months have been passed since the operation, and the patient remains well without perioperative anti-tuberculous medications.  相似文献   

14.
OBJECTIVE: To review the results of stent graft treatment for diseases of the thoracic aorta. DESIGN: A retrospective study of the results of thoracic stent graft procedures in a single centre. METHODS: The results of 30 procedures performed in 24 patients were analysed. Eleven patients had aneurysmal dilatation of the descending thoracic aorta (>5.5 cm), nine patients had complicated type B dissection, three had penetrating ulcers and one had a traumatic pseudoaneurysm. Imaging follow-up consisted of CT scans performed at one, three, six and 12 months following the procedure and annually thereafter. RESULTS: One technical failure occurred due to a ruptured external iliac artery. There were no other immediate failures. The primary technical success rate was 83%. The 30-day procedural and patient mortality rates were 7 and 8%, respectively. No neurological complications occurred. Seven patients had the subclavian artery covered without complications. Secondary intervention was required in 21%. During the follow-up period (mean 11 months, range 1-48 months.) there were five deaths, two of which were related to stent graft infection. CONCLUSION: Thoracic stent grafts offer a realistic alternative to surgery.  相似文献   

15.
A 66-year-old woman was transferred to our hospital for emergency treatment of a ruptured abdominal aortic aneurysm (AAA) and impending rupture of a descending thoracic aortic aneurysm (TAA) caused by a Stanford type-B dissection. She had severe coronary artery disease and a highly calcified aorta, and had been taking long-term steroids for rheumatoid arthritis. Endovascular repair of the TAA failed because the femoral artery was too small, so we performed simultaneous repair of the TAA and the AAA. A temporary axillofemoral bypass was constructed and the AAA was replaced with a bifurcated prosthetic graft. A thoracic stent graft was delivered successfully through a chimney graft of the abdominal graft. About 4 months later, the TAA extended proximally, causing hemoptysis, which was stopped by placing a new stent graft proximal to the previous one. This case report shows that a combination of open and endovascular repair is useful for treating a TAA with an AAA, especially in a small or frail patient.  相似文献   

16.
Aortoesophageal fistula is a relatively rare but highly fatal condition, especially in the case of secondary aortoesophageal fistulas after previous thoracic aortic surgery in which the aortic prosthetic graft itself may be involved in the infection, resulting in an esophagoparaprosthetic fistula. In this report, we describe a complicated case of esophagoparaprosthetic fistula arising after descending thoracic aortic replacement and endovascular pseudoaneurysm repair that was successfully treated by surgical resection and in situ aortic graft replacement using a homograft completely covered with an omental flap, combined with subtotal esophagectomy and staged reconstruction of the alimentary tract. The patient has been doing well for 24 months without signs of recurrent infection.  相似文献   

17.
Endovascular Repair of an Aortopulmonary Fistula via the Axillary Artery   总被引:2,自引:0,他引:2  
A 62-year-old man presented with several months of progressive hemoptysis. He has a history of aortobifemoral bypass and thoracofemoral bypass grafts, which were both removed due to infection. Evaluation with multiple imaging modalities revealed a descending thoracic aortic pseudoaneurysm around the retained Dacron™ graft with bronchiectatic changes and consolidation of the adjacent left lower lobe. No evidence of direct arterial communication between the aorta and the bronchioles was ever demonstrated, but an aortopulnionary fistula was suspected. Endovascular repair with several Excluder aortic cuffs stacked in the thoracic aorta was successfully performed via the axillary artery. Exclusion of the pseudoaneurysm with no evidence of endoleak was noted on computed tomography 2 months postoperatively, at which time the patient reported complete resolution of his hemoptysis. To our knowledge, this is the first report of endovascular repair of an aortopulmonary fistula via the axillary artery.Presented at the Twenty-second Annual Meeting of the Southern Calfornia Vascular Surgery Society, La Jolla, CA, April 30-May 2, 2004.  相似文献   

18.
Aortoesophageal fistula secondary to thoracic aneurysm is rare and is usually fatal without prompt surgical intervention. A 79-year-old man with significant comorbidities and previous cancer surgery was admitted on an emergency basis because of the suspicion of a ruptured thoracic aortic aneurysm. Computed tomographic scan followed by angiography demonstrated a ruptured thoracic aneurysm with aortoesophageal fistula. An endovascular stent graft repair was performed with successful exclusion of both aneurysm and fistula. On postoperative day 6, dyspnea and an isolated episode of hemoptysis occurred. Endoscopy revealed the presence of a bronchoesophageal fistula, which necessitated double exclusion of the esophagus and feeding jejunostomy. At 6 months, clinical, bronchoscopic, and computed tomographic scan follow-up showed complete sealing of the aneurysm and resolution of the bronchoesophageal fistula. At 9 months, the patient was still alive but refused to undergo substernal gastric bypass in an attempt to restore oral feeding. Endovascular repair seems promising as an emergent and palliative treatment of aortoesophageal fistula. To the best of our knowledge, this is the first case in which a bronchoesophageal fistula developed after successful endovascular repair of aortoesophageal fistula. The pathogenesis of this complications remains unclear.  相似文献   

19.
Reconstruction of aortic arch and descending thoracic aortic aneurysms (TAAs) is technically challenging and associated with significant morbidity and mortality. We report our experience with extensive TAAs using a two-stage "elephant trunk" repair, with the second stage completed using an endovascular stent graft (ESG). Over 6 years, 111 patients underwent ESG treatment of TAAs at Mount Sinai Medical Center. Twelve of these patients were referred for ESG placement for the second stage of elephant trunk reconstruction because comorbidities placed them at high risk of open surgical repair. Our database was analyzed for technical and clinical success and perioperative complications. The mean follow-up was 11.8 months (range 1-64 months). Twelve patients (five women and seven men) with a mean age of 69 +/- 10 years underwent repair of their distal aortic arch and descending TAAs. These aneurysms included nine atherosclerotic aneurysms, one pseudoaneurysm, and two penetrating atherosclerotic ulcers. Three patients were symptomatic. Stent graft repair was technically successful in 91.7% or 11 of 12 patients. Excessive aortic arch tortuosity resulted in failure to deploy a stent graft in one patient. An antegrade approach through the open elephant trunk was used in two patients with severe iliac occlusive disease. Endoleaks (type 2) were identified in two patients with no aneurysm expansion; however, a 14 mm expansion over 1 year occurred in a patient with no identifiable endoleak. One early mortality occurred in a patient with a ruptured 6 cm infrarenal AAA after successful exclusion of the 8 cm TAA. Second-stage elephant trunk reconstruction of an extensive TAA using an ESG is effective in the short term. Its long-term durability remains to be determined.  相似文献   

20.
We describe a case of complete endovascular repair of the ascending aorta using a transfemoral approach. A 59-year-old man with a history of two previous sternotomies experienced an ascending aortic pseudoaneurysm arising from the graft-to-graft anastomosis of a previous DeBakey type I aortic dissection repair. A custom-made Zenith TX2 (William Cook Europe ApS, Bjaeverskov, Denmark) thoracic aortic aneurysm endovascular graft, designed specifically for the ascending aorta, was introduced through the left femoral artery and deployed under a rapid ventricular pacing protocol to achieve precise placement between the sinotubular junction and the aortic arch.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号