首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 156 毫秒
1.
穆晶  李一壮  陈晖 《国际眼科杂志》2012,12(12):2335-2337
目的:比较双眼植入多焦点人工晶状体(IOL)和单眼视设计两种方法对白内障术后视功能的影响。

方法:选择2011-01/2012-01于本中心诊断为双眼白内障患者45例90眼,分为多焦点组23例和单眼视组22例,分别植入AcrySof ReSTOR+3D多焦点IOL(SN6AD1,美国Alcon)和单焦点非球面AcrySof IQ(SN60WF)IOL。记录术后3mo时两组患者裸眼远、近、中距离视力,以及对比敏感度、立体视、视功能和生存质量调查问卷,评价患者主观的视觉功能和脱镜率。对计量资料中两组数据进行正态性检验分析,满足正态分布者行t检验,对计数资料行χ2检验。

结果:术后两组双眼裸眼远视力(t=2.001,P=0.052)、中距离视力(t=1.304,P=0.199)、近视力(t=1.642,P=0.108),差异无统计学意义。各空间频率对比敏感度差异无统计学意义(P>0.05)。未矫正远距离立体视差异有统计学意义(P<0.05)。两组术后脱镜率均大于96%。主要视觉干扰中,复视、夜间视物困难和眩光多焦点组比例较高。

结论:双眼植入多焦点IOL与单焦点IOL单眼视设计基本均能获得全程视力,术后脱镜率以及视功能无差异(P>0.05)。  相似文献   


2.
韦敏  杜旭果  高彩品 《国际眼科杂志》2012,12(12):2345-2440
目的:通过对Acrysof ReSTOR SA60D3多焦点人工晶状体植入和Acrysof SN60AT单焦点人工晶状体植入术后3a远近视力及拟调节力的对比研究,探讨Acrysof ReSTOR SA60D3多焦点人工晶状体中期的临床应用效果。

方法:对在同一时期接受白内障超声乳化人工晶状体植入手术的年龄相关性白内障患者68例80眼进行回顾性分析。其中A组40眼植入Acrysof ReSTOR SA60D3多焦点人工晶状体,B组40眼植入Acrysof SN60AT单焦点人工晶状体。术后3a随访观察术眼的屈光状态,裸眼远、近视力,矫正远、近视力, 最佳远矫下近视力,对比敏感度,问卷调查视觉质量和满意度,术后脱镜率及并发症等。

结果:术中术后两组均无严重并发症。两组患者术后均有良好的远视力和最佳矫正近视力,差异无统计学意义; A组患者裸眼近视力明显优于B组,A组脱镜率达82%,B组脱镜率16%; 术后对比敏感度差异无统计学意义,术后视觉症状无明显差异,但是术后满意度A组明显高于B组。

结论:Acrysof ReSTOR SA60D3多焦点人工晶状体植入安全有效,可为患者同时提供良好的远、近视力,值得临床推广应用。  相似文献   


3.
张春元  奚婷 《国际眼科杂志》2012,12(10):1880-1881
目的:观察高度近视合并白内障植入非球面与球面人工晶状体术后视觉质量。

方法:回顾性分析高度近视合并白内障患者42眼,其中植入非球面IOL(Alcon SN60WF)22眼,植入球面IOL(Alcon SN60AT)20眼,所有病例术后裸眼视力均>0.2,术后6mo对视力、表观调节力、对比敏感度等视功能检查。

结果:术后6mo非球面IOL和球面IOL两组的矫正远视力、矫正远视力后的近视力、表观调节力比较差异均无统计学意义(P>0.05),在暗视及暗视眩光状态下,低、中空间频率非球面IOL组CS和GCS优于球面IOL组,差异有统计学意义(P<0.05),在高频区、明视及明视眩光状态下两组间CS和GCS差异无统计学意义(P>0.05)。

结论:高度近视合并白内障患者非球面IOL植入术后CS和GCS优于球面IOL植入术后,可以改善视觉质量。  相似文献   


4.
孙兢  冯绍鸿  辛志坤 《国际眼科杂志》2010,10(12):2278-2280
目的:与非球面AcrySof ReSTOR +4D人工晶状体比较,初步观察植入ReSTOR +3D和ReSTOR +4D人工晶状体眼的视功能,以评价非球面AcrySof ReSTOR +3D人工晶状体植入术后的效果。方法:全组36例40眼老年性白内障患者行白内障超声乳化吸除联合人工晶状体植入术,术后3mo检查患者的裸眼远、中(60cm)、近视力(40cm),最佳矫正远视力和中、近视力,对比敏感度,进行生活问卷。结果:两组术后的远视力,近视力均无统计学差异(P>0.05),植入非球面AcrySof ReSTOR +3D人工晶状体组平均中距离视力比植入非球面AcrySof ReSTOR +4D人工晶状体组有显著提高(P<0.01)。结论:非球面AcrySof ReSTOR +3D人工晶状体在远、中、近距离均能提供良好的视力,尤其是中距离视力比+4D有了显著改善,有极高的患者满意度和脱镜率。  相似文献   

5.

目的:探讨区域折射多焦点人工晶状体SBL-3的临床应用效果。

方法:选取2016-02/2017-06于本院行白内障超声乳化摘除术联合多焦点人工晶状体SBL-3植入的26例26眼年龄相关性白内障患者纳入SBL-3组; 选取同期于本院行白内障超声乳化摘除术联合单焦点人工晶状体TecnisZA9003植入的28例28眼年龄相关性白内障患者纳入对照组。比较两组患者术后3mo的裸眼视力、矫正视力、对比敏感度及患者满意度。

结果:术前两组患者的裸眼远、中、近视力相比差异均无统计学意义(P>0.05)。术后3mo,两组患者的裸眼远、中、近视力较术前均得到明显改善(P<0.05); SBL-3组患者裸眼中近视力、最佳矫正远视力下中视力和近视力均显著优于对照组(P<0.05); SBL-3组患者在明光、暗光、明光眩光和暗光眩光下不同空间频率(3、6、12、18c/d)的对比敏感度以及视觉质量满意度均显著优于对照组(P<0.05)。

结论:区域折射多焦点人工晶状体SBL-3不仅可以提供较好的远视力,还可提供更佳的中视力、近视力以及对比敏感度,极大地提高了患者术后的视觉质量满意度。  相似文献   


6.
目的 探讨年龄相关性白内障患者行超声乳化联合AcrySof ReSTOR多焦点人工晶状体(MIOL)植入术后的视功能及视物满意度.方法 回顾性研究.将20例(40眼)植入AcrySof ReSTOR+3D MIOL患者(观察组)与20例(40眼)植入AcrySof IQ单焦点人工晶状体患者(对照组)进行对比,观察两组患者术后3个月相同光照条件下远、中、近裸眼及最佳矫正视力和立体视锐度;并对术后视物满意度进行问卷调查.所得数据资料的比较采用秩和检验.结果 观察组的裸眼中距视力、远矫正下的中距视力、裸眼近视力、远矫正下的近视力均显著高于对照组(Z=2.978,P<0.01;Z=3.040,P<0.01;Z=3.471,P<0.01;Z=3.098,P<0.01).观察组立体视锐度显著高于对照组(Z=2.264,P<0.05).观察组中,中距离、近距离视物满意度(96%、100%)明显好于对照组(77%、50%).结论 双眼植入AcrySof ReSTOR+3DMIOL患者拥有良好的全程视力以及近立体视锐度,生活质量得到了提高.  相似文献   

7.
目的::探讨老年性白内障多焦点人工晶状体( multiple focal intraocular lens,MIOL)同轴微切口植入的视觉效果。方法:回顾性非随机病例对照研究。选择2013-02/2014-08在湖州师范学院附属第一医院植入AcrySof ReSTOR人工晶状体的老年性白内障患者48例60眼为观察组,进行同轴微切口白内障超声乳化联合AcrySof ReSTOR人工晶状体植入。选择同期一般资料匹配的同轴微切口单焦点人工晶状体植入患者36例50眼为对照组。观察并比较两组患者术后裸眼远视力、裸眼近视力、日常用眼满意度。结果:两组患者人工晶状体均成功植入。观察组术后3 mo裸眼远视力为0.75±0.25,裸眼近视力为0.70±0.18,日常用眼满意度为96%。对照组术后3 mo裸眼远视力为0.79±0.36,裸眼近视力为0.31±0.11,日常用眼满意度为75%。两组患者术后3 mo裸眼远视力比较,无统计学差异(P>0.05),术后3mo裸眼近视力、日常用眼满意度比较,有统计学差异(P<0.05)。结论:多焦点人工晶状体术后3 mo裸眼近视力、日常用眼满意度优于单焦点人工晶状体。两组患者术后3 mo裸眼远视力结果无差异。  相似文献   

8.
郝咪  龙潭  马挺  王睿 《国际眼科杂志》2021,21(12):2118-2123

目的:研究散光矫正型双焦点人工晶状体与双焦点人工晶状体混搭植入术后的双眼视觉质量。

方法:横断面研究。纳入2020-01/2021-01收治的年龄相关性白内障患者54例108眼,按植入人工晶状体及术前角膜散光不同分为3组,A组21例42眼术前角膜散光均<1.0D,双眼植入双焦点人工晶状体; B组15例30眼术前角膜散光均≥1.0D,双眼植入散光双焦点人工晶状体; C组18例36眼,一眼术前角膜散光<1.0D,另一眼术前角膜散光≥1.0D,前者植入双焦点人工晶状体,后者植入散光双焦点人工晶状体。比较三组患者术前单眼视力,术后双眼视力、残余散光、双眼离焦曲线、对比敏感度(CS),三组患者术后进行问卷调查评估视觉质量。

结果:三组患者术前视力、术前眼压均无差异(P>0.05)。A组术后残余散光显著高于另两组(P=0.012,<0.05)。B组和C组双眼远视力优于A组(均P<0.05); B组和C组双眼近视力优于A组(均P<0.01); A组双眼中视力优于B组和C组(均P<0.01)。明视眩光6、12c/d,暗视6、12、18c/d,以及暗视眩光1.5、3、6、12、18c/d的空间频率下A组CS较B组和C组显著降低(均P<0.05)。术后视功能调查表三组间无差异(P>0.05)。

结论:散光双焦人工晶状体与双焦人工晶状体混搭植入可改善患者术后视觉质量。矫正散光有助于提高术后患者的视觉CS,但是散光全矫后,可能会导致患者术后中视力的下降。  相似文献   


9.
目的:比较白内障超声乳化联合植入非球面AcrySofReSTOR+3D与非球面AcrySof ReSTOR+4D术后人工晶状体眼的视功能状态及患者的主观满意度,评价非球面AcrySof ReSTOR+3D人工晶状体的临床效果及应用价值。方法:收集我院超声乳化联合非球面+3D植入56例60眼为实验组,非球面+4D58例60眼为对照组。术后3mo行裸眼远、中、近视力及最佳矫正远、近视力,角膜散光度,对比敏感度检查及问卷调查(视觉干扰、满意度及脱镜率),并对数据进行统计学分析。结果:两组术后裸眼远、近视力及最佳矫正远、近视力无明显差异(P>0.05),中距离视力实验组(0.68±0.13)明显优于对照组(0.55±0.08),差异显著(P<0.05);术前散光0.75±0.13D,单切口术后角膜散光0.41±0.15D;术前散光1.25±0.18D,双切口术后角膜散光0.72±0.21D,术前术后比较差异有统计学意义(P<0.05)。各空间频率对比敏感度组间无明显差异(P>0.05)。两组术后均无明显夜视力下降、眩光、光晕等视觉干扰现象(P>0.05),在满意度评价上,视远及视近方面两组患者满意度无明显差异(P>0.05),中距离实验组满意度明显高于对照组(P<0.05),实验组脱镜率明显高于对照组(P<0.05)。结论:非球面AcrySof ReSTOR+3D人工晶状体为患者提供良好的远、中、近全程视力和视觉质量,尤其中距离视力比+4D有明显改善,实现了患者高度满意率和脱镜率。因此我们认为非球面AcrySof ReSTOR+3D有良好的临床效果及广泛的临床应用价值。  相似文献   

10.
刘思源  杨旭 《国际眼科》2017,10(11):2134-2136

目的:探讨Oculentis区域折射多焦点人工晶状体植入术后早期临床疗效。

方法:将2016-10/2017-01行超声乳化吸出术联合Oculentis区域折射多焦点人工晶状体植入术的白内障患者20例作为试验组,将同一时段行超声乳化吸出联合人类光学Aspira-aA单焦点非球面人工晶状体植入术的白内障患者20例作为对照组。检查患者术后3mo裸眼远视力、近视力、屈光状态、UBM检查、阅读戴镜率、不良体验率(光晕、眩光、雾视等现象发生率)的情况。

结果:术后3mo,试验组裸眼远视力(0.10±0.03)与对照组比较差异无统计学意义(t=1.74,P>0.05)。试验组裸眼近视力(0.11±0.04)与对照组比较差异有统计学意义(t=15.53,P<0.05)。术后3mo,试验组人工晶状体居中性均良好,阅读戴镜率为5%,不良体验率(光晕、眩光、雾视现象发生率)仅为5%,而对照组阅读戴镜率为100%。

结论:Oculentis区域折射多焦点人工晶状体植入术可提供良好的裸眼远视力和近视力,能极大地提高白内障术后脱镜率,解决白内障术后老视问题,且患者舒适度极佳,光晕、眩光、雾视现象少有发生,手术安全可靠。  相似文献   


11.
目的:通过观察白内障超声乳化摘除联合ReSTOR衍射型多焦点人工晶状体植入术后患者的视力、受眩光、光晕干扰程度及老视镜脱镜率,评价衍射型多焦点人工晶状体眼的视觉质量。方法:将60例(68眼)年龄相关性白内障患者随机分为2组,分别行白内障超声乳化摘除并植入ReSTOR SA60D3衍射型多焦点人工晶状体(多焦组)和Natural SN60AT单焦点人工晶状体(单焦组),观察术后裸眼及最佳矫正远、近视力,受眩光、光晕干扰程度及阅读时戴镜情况。结果:两组患者术后裸眼远视力、最佳矫正远视力和最佳矫正近视力均无显著性差异(P>0.05)。多焦组术后裸眼近视力和最佳视远矫正时近视力明显优于单焦组(P<0.05),且近距离阅读时不需戴老视镜的患者多焦组22例(73.3%),而单焦组仅4例(13.3%),差异有统计学意义(P<0.05)。多焦组患者术后受眩光、光晕干扰较单焦组明显(P<0.05)。结论:ReSTOR衍射型多焦点人工晶状体能提供良好的远、近视力,有效降低患者对老视镜的依赖,提高了白内障患者术后的视觉质量。  相似文献   

12.
ReSTOR intraocular lens implantation in cataract surgery: quality of vision   总被引:8,自引:0,他引:8  
PURPOSE: To compare the visual outcome and subjective visual symptoms in patients who had implantation of the AcrySof ReSTOR multifocal intraocular lens (IOL) (Alcon Laboratories) with those in patients who received the AcrySof SA60AT monofocal IOL (Alcon Laboratories) in cataract surgery. SETTING: Southend Hospital, Essex, United Kingdom. METHODS: Eighty eyes of 40 patients received the ReSTOR multifocal IOL after cataract extraction. They were closely paired in age, sex, and ocular findings with patients who had monofocal IOL implantation during the same period. The distance and near visual acuities were compared, and patient satisfaction with their vision, visual symptoms, and spectacle dependence was assessed using a standardized questionnaire. RESULTS: There was no significant difference in the mean uncorrected and best corrected distance visual acuities between the groups. An uncorrected distance visual acuity of 20/30 or better was achieved in 93.8% eyes in the multifocal group and 82.5% in the monofocal group and of 20/20 or better in 57.5% and 40.0%, respectively (P = .18). Uncorrected near visual acuity was 20/30 or better in 75.0% of eyes in the multifocal group and 3.8% in the monofocal group. Reading glasses were required by 2.5% in the multifocal group and by 92.5% in the monofocal group. Satisfactory uncorrected intermediate distance vision was achieved in 75.0% of eyes in the multifocal group and 87.5% in the monofocal group (P = .089); 85.0% of patients in the multifocal group and 7.5% in the monofocal group never had to wear glasses. Moderate glare was reported by 21.3% in the multifocal group and 7.5% in the monofocal group (P = .008); no patient reported severe glare. In the multifocal group, severe halos and moderate halos occurred in 3.8% [corrected] of eyes and 16.3% [corrected] of eyes, respectively. CONCLUSIONS: The AcrySof ReSTOR IOL provided predictably good uncorrected distance and uncorrected near acuities. Spectacle independence was significantly higher with this multifocal IOL, which outweighed the photic symptoms it caused.  相似文献   

13.
吴杰  朱磊 《眼科新进展》2017,(6):572-575
目的 对比AcrySof多焦点人工晶状体和单焦点人工晶状体植入术后的早期临床疗效及拟调节力.方法 选取行白内障超声乳化摘出并人工晶状体植入术的年龄相关性白内障患者138例158眼,根据植入的人工晶状体不同,分为观察组和对照组.观察组60例73眼,植入AcrySof ReSTOR SN6AD1多焦点人工晶状体;对照组78例85眼,植入AcrySof Natural单焦点人工晶状体,比较术后1周、1个月和3个月两组患者的裸眼及最佳矫正远、中、近视力,并对比术后3个月时两组患者的拟调节力和生活质量调查评分.结果 术后1周、1个月和3个月两组患者均能获得满意的远视力,观察组裸眼中视力分别为0.49±0.19、0.72±0.21、0.77±0.23,对照组分别为0.24±0.21、0.27±0.22、0.28±0.24,两组比较差异均有统计学意义(均为P<0.05);裸眼近视力观察组分别为0.47 ±0.20、0.70±0.22、0.80±0.24,对照组分别为0.21 ±0.23、0.23 ±0.19、0.26±0.18,两组比较差异均有统计学意义(均为P<0.05);两组患者的裸眼远视力及最佳矫正远、中、近视力比较差异均无统计学意义(均为P>0.05).术后3个月,观察组的视远拟调节力和视近拟调节力分别为(2.56±0.82)D、(3.19±1.13)D,对照组分别为(0.87±0.57)D、(1.03 ±0.59)D,两组比较差异均有统计学意义(均为P<0.05).观察组患者VF-14量表评分和视近时戴镜评分分别为(92.21±4.22)分、(4.23±0.85)分,对照组分别为(71.23±3.96)分、(2.01±0.71)分,两组比较差异均有统计学意义(均为P<0.05).结论 多焦点人工晶状体能够帮助患者获得全程视力,解决单焦点人工晶状体视中、视近的不足,改善拟调节力,提高患者的生活视觉质量.  相似文献   

14.
目的:通过对非球面矫正型多焦点人工晶状体与非球面人工晶状体的比较,探讨白内障超声乳化联合非球面散光矫正型人工晶状体植入术后患者的远近视力、剩余散光、视远脱镜率、视近脱镜率、视觉质量和患者满意度等情况.方法:选取2014-02/2016-06在我院确诊为年龄相关性白内障的患者46例48眼,实行白内障超声乳化摘除联合人工晶状体植入术,分别植入AcrySof IQ ReSTOR Toric人工晶状体23例24眼作为试验组;AcrySof IQ 人工晶状体23例24眼作为对照组.术后随访6mo,观察两组患者术后裸眼远视力(UCDVA)、最佳矫正远视力(BCDVA)、裸眼近视力(UCNVA)、最佳矫正近视力(BCNVA)、剩余散光和术后患者视远脱镜率、视近脱镜率、患者对手术疗效的满意度.结果:术后1、3、6mo两组患者最佳矫正远视力和最佳矫正近视力无统计学差异(P>0.05),而裸眼远视力、裸眼近视力均有统计学差异(P<0.05).两组患者术后1wk,1、3、6mo的剩余散光差异有统计学意义(P<0.05),术后6mo时两组患者对疗效满意度差异有统计学意义(P<0.05);术后6mo视近视远脱镜率,试验组明显高于对照组,差异有统计学意义(P<0.05).结论:非球面散光矫正型人工晶状体具有良好的近附加和散光矫正,可为患者提高良好的裸眼远视力和裸眼近视力,明显提高患者术后的脱镜率和对疗效的满意度,是白内障术后患者尤其是散光伴有明显视近阅读需求患者的福音.  相似文献   

15.
Array多焦点与单焦点晶状体的视觉效果比较   总被引:5,自引:0,他引:5  
袁非  黎蕾  朱志忠  王历阳 《眼科研究》2003,21(4):425-427
目的 评价白内障超声乳化术后植入Array多焦点人工晶状体的视觉效果。方法 将白内障或半透明晶状体超声乳化术后33例(45眼)植入Array多焦点人工晶状体(研究组)与27例(35眼)植入硅胶单焦点人工晶状体(对照组)的临床资料进行比较。结果 研究组术后3个月裸眼远视力≥0.4为97.8%,≥0.7为68.9%,近视力≥0.4为100%;对照组则分别为100%、40.0%和45.7%。两组远视力没有明显差别而近视力有明显差别。研究组91%的患者术后有眩光和光晕,但在3个月内基本适应;对照组基本没有眩光和光晕。结论 Array多焦点晶状体可以提供一定范围内良好的预期远近视力,近期效果满意;但也存在不足。  相似文献   

16.
目的:测定衍射折射型多焦点人工晶状体眼术后远期的视觉质量。方法:采取随机对照临床试验研究方法,将67例白内障患者分两组,其中30例33眼植入多焦点人工晶状体,37例37眼植入单焦点人工晶状体。术后3mo和1a进行裸眼远视力、中间视力、近视力、矫正远、中、近视力和对比敏感度检查。视功能和生存质量调查问卷评价患者主观的视觉功能。结果:(1)术后多焦点组裸眼近视力优于单焦点组(P<0·05),中间距离视力亦优于单焦点组(P<0.05),两组裸眼和矫正远视力、近视力及最佳矫正远视力下近视力差异无显著性。术后1a和3mo相比,差异无显著性意义。(2)术后两组对比敏感度均低于正常范围,空间分布差异无统计学意义。(3)两组术后多焦点组脱镜率达83%,而单焦点组脱镜率为32%,两组比较差异有显著性(P<0·05)。多焦点组4例有眩光。多焦点组患者对全程视力的满意度高于单焦组患者。结论:多焦点人工晶状体能提供良好的全程视力,但近视力更好,视觉症状轻,脱镜率更高,有效地提高白内障患者术后的视觉质量。  相似文献   

17.
PURPOSE: To compare the visual acuity and contrast sensitivity in eyes with the AcrySof ReSTOR multifocal intraocular lens (IOL) (Alcon) and eyes with the monofocal AcrySof SA60AT IOL. SETTING: Policlinico Umberto I, Department of Ophthalmology, Rome, and private clinical practice, Rome, Italy. METHODS: One hundred eyes had phacoemulsification cataract extraction and implantation of a ReSTOR multifocal IOL in the capsular bag. Inclusion criteria were corneal astigmatism less than 1.5 diopters (D), myopia less than 4.0 D, and no associated ocular disease. A complete ophthalmic examination, including uncorrected visual acuity, best spectacle-corrected visual acuity, and contrast sensitivity, was performed 6 months postoperatively. Results were compared with those in 40 eyes with the AcrySof monofocal IOL single-piece IOL. RESULTS: In the multifocal group, 90 eyes (90%) had an uncorrected distance visual acuity of 20/25 or better (logMAR<0.10) and an uncorrected near visual acuity at 35 cm of J3 or better (logMAR 0.14). The multifocal group and monofocal group had similar distance uncorrected and best corrected visual acuities; however, the multifocal group had significantly better near uncorrected acuity. The mean contrast sensitivity values were 18.28 dB (static program) and 17.95 dB (dynamic program) in the multifocal group and 19.18 dB (static program) and 21.2 dB (dynamic program) in the monofocal group. CONCLUSIONS: The ReSTOR multifocal IOL provided a satisfactory full range of vision; 92% of the patients achieved total spectacle independence. Contrast sensitivity was lower than with the SA60AT monofocal IOL.  相似文献   

18.
目的客观与主观检测结合评价非球面设计的多焦点与单焦点人工晶状体植入术后的视觉质量。方法132例(207只眼)白内障患者分别植入非球面的多焦点人工晶状体AcrySof IQ ReSTOR IOL和单焦点人工晶状体AcrySof IQ IOL。记录患者手术后的裸眼远、近视力,矫正远、近视力。术后3个月检测患者明视、暗视和暗视眩光状态的对比敏感度。采用VF-14(Visual function-14)视功能和生存质量调查问卷评价患者主观的视觉质量。结果术后两组裸眼远视力(t=0.61,P〉0.05)最佳矫正近视力(t=1.877,P〉0.05)差异无统计学意义。非矫正近视力多焦点组优于单焦点组(t=11.38,P〈0.001),单焦点组在明光、暗光、暗光眩光条件下各空间频率对比敏感度均高于多焦点组,明光条件下3cpd和6cpd空间频率差异有统计学意义(P〈0.05),暗光眩光条件下中高频率差异有统计学意义(P〈0.05),两组无患者存在严重的视觉干扰现象。两组术后视远时脱镜率均大于98%,视近时脱镜率多焦点组为78.9%,单焦点组为10.9%。结论与单焦点人工晶状体相比,除了对比敏感度下降,多焦点人工晶状体能提供令人满意的术后视功能和生活质量,患者能获得较高的视觉质量。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号