首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
目的 分析白内障超声乳化术联合旋转非对称折射型多焦点人工晶状体(multifocal intraocular lens,MIOL)植入术后患者远、中、近视力的影响因素。方法 采用前瞻性研究,纳入2018年8月至2019年8月在我院行白内障超声乳化术联合旋转非对称折射型MIOL(SBL-3)植入术患者35例44眼,术后随访3个月。观察术前及术后3个月患者的裸眼远视力(uncorrected distance visual acuity,UDVA)、最佳矫正远视力(corrected distance visual acuity,CDVA)及患者术后3个月时的离焦曲线,小数视力均转换为logMAR视力表示;记录术前及术后明室及暗室下瞳孔直径(pupil diameter,PD)及kappa角,日夜瞳孔中心位移以及术后眼内像差。并将上述因素与患者术后UDVA、CDVA及离焦曲线中各屈光度对应的视力进行Spearman相关性分析。结果 患者术后3个月时UDVA和CDVA LogMAR视力平均值为0.10(0.00~0.20)、0.00(0.00~0.20),均较术前明显提高,差异均有统计学意义(均为P<0.05);垂直彗差及垂直三叶草均较术前增大,差异均有统计学意义(均为P<0.05)。Spearman相关性分析显示,眼内水平三叶草差与-0.5 D及-1.0 D离焦水平处对应的logMAR视力相关系数分别为-0.377、-0.369(均为P<0.05),眼内垂直三叶草差与-2.5 D离焦水平对应的logMAR视力相关系数为-0.347(P<0.05),眼内总高阶像差与-0.5~-3.5 D离焦范围内对应的logMAR视力均呈负相关(均为P<0.05)。眼内球差与UDVA、-0.5~-2.0 D离焦水平对应的logMAR视力均呈正相关(均为P<0.05)。此外,术后明室kappa角与-0.5 D离焦水平对应的视力呈正相关(r=0.315,P<0.05)。结论 SBL-3 MIOL由于其设计特点,植入眼内后会引入特定的高阶像差,包括三叶草差及彗差。其中,三叶草差的增加对全程视力具有正相关,而垂直彗差一定程度上影响了SBL-3 MIOL植入的术后远视力。Kappa角过大可能影响SBL-3 MIOL术后近视力。  相似文献   

2.
目的比较三焦点衍射型人工晶状体(IOL)和双焦点折射型IOL植入后患者的术后视觉质量差异。方法回顾性队列研究。收集2019年3月至2020年7月于北京大学第三医院眼科行超声乳化白内障吸除联合后房型IOL植入的52例(104只眼)患者。其中,男性17例(34只眼),女性35例(70只眼);年龄36~87岁,平均年龄(69.3±11.2)岁。根据患者植入IOL种类分为区域折射组和衍射三焦组。区域折射组植入Lenstec SBL-3型IOL;衍射三焦组植入AT LISA tri 839MP型三焦点IOL。比较患者术后3个月裸眼近视力(UNVA)、裸眼中视力(UIVA)及裸眼远视力(UDVA),最佳矫正视力(BCVA)、离焦曲线、客观视觉质量、脱镜率、不良视觉现象及满意度。两组患者视功能相关生活质量问卷评分以(±s)表示;UNVA、UIVA、UDVA、BCVA、调制传递函数截止频率(MTF cut-off)、斯特列尔比(SR)、客观散射指数(OSI)、对比度视力(VA)及患者满意度以中位数和四分位数表示,组间比较采用Mann-Whitney U检验。等效球镜屈光度(SE)的分布、脱镜率及不良视觉率以百分比表示,组间比较采用χ^(2)检验。Spearman相关性分析患者术后客观视觉质量与BCVA的关系。结果衍射三焦组术后最小分辨角度对数视力(logMAR)UNVA、UIVA、UDVA及BCVA分别为0.10(0.05,0.10)、0.10(0.00,0.20)、0.10(0.10,0.20)及0.00(0.00,0.05);区域折射组分别为0.05(0.00,0.10)、0.10(0.00,0.20)、0.10(0.00,0.20)及0.00(0.00,0.05),UNVA比较的差异有统计学意义(Z=-2.596,P<0.05)。衍射三焦组SE在±0.25 D、±0.50 D、±0.75 D及±1.00 D处,分布分别占34.6%、65.4%、90.4%及100.0%;区域折射组SE在±0.25 D、±0.50 D、±0.75 D及±1.00 D处,分别占57.7%、71.2%、78.9%及92.4%。两组SE整体分布比较的差异有统计学意义(χ^(2)=27.083,P<0.05)。两组平均SE分别为(-0.38±0.43)D和(-0.25±0.49)D,差异无统计学意义(t=0.667,P>0.05)。离焦曲线分析显示,球镜屈光度为2.00 D、-2.00 D及-2.50 D时两组患者的logMAR BCVA比较的差异均有统计学意义(Z=-2.378,-2.416,-2.821;P<0.05)。衍射三焦组术后MTF cut-off、SR、OSI、VA 100%、VA 20%及VA 9%分别为27.7(21.2,37.6)c/deg、0.14(0.10,0.21)、2.4(1.7,2.9)、0.9(0.7,1.3)、0.6(0.4,0.8)及0.3(0.2,0.5);区域折射组分别为18.8(14.1,24.4)c/deg、0.11(0.09,0.13)、2.4(1.8,3.2)、0.6(0.5,0.8)、0.4(0.3,0.5)及0.2(0.2,0.3)。两组患者术后MTF cut-off、SR、OSI、VA 100%、VA 20%及VA 9%与logMAR BCVA呈正相关,且有统计学意义(r=-0.352,-0.211,0.542,0.324,-0.314,-0.287;P<0.05)。OSI与logMAR BCVA的相关度最高且两组间OSI比较的差异无统计学意义(Z=-0.807,P>0.05)。两组患者视功能相关生活质量问卷总分分别为(88.28±11.41)分和(87.43±12.62)分;视近脱镜率分别为80.8%和84.6%;不良视觉现象出现概率分别为23.1%和19.2%;平均满意度分别为3(3,4)和3(3,4)。结论两种多焦点IOL均能提高患者术后的主客观视觉质量,术后的有效性、准确性、生活质量、术后脱镜率及满意度相当;此外,区域折射组的术后UNVA优于衍射三焦组,衍射三焦组客观视觉质量均优于区域折射组,OSI可作为早期后囊膜混浊发现及手术时机选择的指标。  相似文献   

3.
目的:比较三焦点人工晶状体(IOL)与单焦点IOL植入术后早期的视力情况、视觉质量及患者满意度。方法:前瞻性临床研究。选取2016年4-7月就诊于中国医科大学附属第四医院眼科确诊为白内障欲行手术治疗的患者44例(50眼),植入三焦点IOL为实验组(22例,25眼),植入单焦点IOL为对照组(22例,25眼)。随访至术后3个月,测试单眼裸眼远中近视力(LogMAR)、离焦曲线、主观散射光、客观散射指数(OSI)、调制传递函数截止频率(MTF cutoff)、斯特列尔比(SR)、像差,并 发放调查问卷统计患者满意度、脱镜率以及光晕发生率。采用配对t检验、Wilcoxon符号秩检验及χ 2 检验进行数据分析。结果:术后3个月,2组间远视力差异无统计学意义,中、近视力方面,实验组(0.12±0.11、0.17±0.11)优于对照组(0.28±0.08、0.47±0.16) (t=-5.912、-8.504,均P < 0.001);实验组(2.02±0.93)的OSI高于对照组(1.13±0.31) (t=-3.311,P=0.001);2组间MTFcutoff、SR、主观散射光以及像差的差异均无统计学意义;实验组在满意度和脱镜率方面优于对照组( χ 2 =4.50,P=0.034; χ 2 =30.65,P < 0.001),光晕发生率在2组间差异无统计学意义。结论:三焦点IOL植入术后,患者拥有良好的远、中、近全程视力及视觉质量。  相似文献   

4.
目的比较非对称区域折射型多焦点人工晶状体(IOL)与衍射型三焦点IOL治疗年龄相关性白内障的疗效。 方法回顾性研究。收集2016年11月至2018年6月于成都爱尔眼科医院白内障中心行超声乳化白内障吸除联合IOL植入术57例(57只眼)患者的病历资料。其中,男性28例(28只眼),女性29例(29只眼);年龄50~76岁,平均年龄(63.3±5.5)岁。按照植入IOL的类型将患者分为区域折射组和衍射三焦组。检查并记录两组患者术前与术后3个月的术眼屈光度、裸眼远距离视力(UDVA)、裸眼中距离视力(UIVA)、裸眼近距离视力(UNVA)、最佳矫正远视力(BCDVA)、客观散射指数(OSI)、调制传递函数截止空间频率(MTF cutoff)、斯特列尔比值(SR)以及对比度视力。根据中文版VF-14视功能指数量表对上述指标进行评分,并对患者进行问卷调查。两组患者患眼的眼轴长度、角膜散光、术前UDVA、术前BCDVA、术后OSI、MTF cutoff、SR及中文版VF-14视功能指数量表评分等指标采用均数±标准差表示,并以独立样本t检验进行比较。UDVA、UIVA、UNVA、BCDVA及对比度视力采用中位数和四分位数间距表示。采用Mann-Whitney U检验,比较两组患者术后3个月术眼的UDVA、UIVA、UNVA、BCDVA以及对比度视力。 结果区域折射组和衍射三焦组患者的术后球镜屈光度分别为-0.75 D~+0.50 D和-0.50 D~+1.00 D。两组患者球镜屈光度位于-0.50 D~+0.50 D区间者占比的比较,差异无统计学意义(χ2=0.000,P>0.05)。两组患者术后柱镜屈光度分别为0.00 D~-0.75 D和0.00 D~-1.00 D。两组患者柱镜屈光度位于-0.75 D~-1.00 D者占比的比较,差异无统计学意义(χ2=0.459,P>0.05)。区域折射组患者术后的UDVA、UIVA、UNVA及BCDVA分别为0.10(0.00,0.10)、0.20(0.20,0.20)、0.20(0.10,0.20)及0.00(0.00,0.10);衍射三焦组患者术后分别为0.05(0.00,0.10)、0.20(0.10,0.20)、0.10(0.10,0.20)及0.00(0.00,0.05)。经Mann-Whitney U检验,两组患者术后UDVA、UNVA和BCDVA的比较,差异无统计学意义(Z=-0.169,-1.265,-1.410;P>0.05);UIVA的比较,差异有统计学意义(Z=-2.708,P<0.05)。区域折射组患者术后的OSI、MTF cutoff及SR分别为(1.9±0.7)、(24.755±7.751)c/deg和(0.126±0.029);衍射三焦组患者术后分别为(1.6±0.7)、(35.813±9.984)c/deg和(0.195±0.083)。经t检验,两组患者MTF cutoff和SR的比较,差异有统计学意义(t=-5.419,-4.822;P<0.05);OSI的比较,差异无统计学意义(t=1.959,P>0.05)。区域折射组患者术后在100%、20%和9%对比度下的对比度视力分别为0.70(0.60,0.90)、0.50(0.40,0.60)和0.30 (0.20,0.30);衍射三焦组分别为1.20(0.95,1.50)、0.70(0.60,0.90)和0.50(0.30,0.70)。经Mann-Whitney U检验,两组患者对比度视力的比较,差异有统计学意义(Z=-4.882,-4.829,-3.676;P<0.05)。区域折射组与衍射三焦组的中文版VF-14视功能指数量表评分分别为(94.39±4.74)分与(96.86±3.63)分,两者比较的差异无统计学意义(t=-0.075,P>0.05)。区域折射组与衍射三焦组眩光的发生率分别为10.7%与6.9%。两组近脱镜率和眩光发生率的比较,差异无统计学意义(χ2=0.181,0.002;P>0.05)。区域折射组与衍射三焦组轻度光晕的发生率分别为3.57%与27.59%,差异有统计学意义(χ2=4.505,P<0.05)。 结论两种老视矫正型IOL均能为年龄相关性白内障患者提供较好的全程视力,术后患眼屈光度可预测性好,而衍射型三焦点IOL客观视网膜成像质量的评估方面较区域折射型多焦点IOL略好。  相似文献   

5.
巫雷  王文惠 《眼科新进展》2019,(10):956-960
目的 评价三焦点非球面衍射型人工晶状体植入术后的双眼立体视功能及视觉质量。方法 非随机同期对照临床研究。对38例76眼单纯性白内障患者行超声乳化吸出联合人工晶状体植入术,依据植入人工晶状体类型不同分为2组:双眼均植入三焦点人工晶状体组18例36眼为三焦组,双眼均植入单焦点人工晶状体组20例40眼为单焦组。随访记录2组患者术后双眼近立体视功能、视力[单眼及双眼裸眼远距离视力(uncorrected distance visual acuity,UDVA)、裸眼中距离视力(uncorrected intermediate visual acuity,UIVA)、裸眼近距离视力(uncorrected near visual acuity,UNVA)、矫正远距离视力(corrected distance visual acuity,CDVA)、矫正远视力基础上的中距离视力(distance-corrected intermediate visual acuity,DCIVA)、矫正远视力基础上的近距离视力(distance-corrected near visual acuity,DCNVA)]和等效球镜度。利用VF-14-CN量表行主观问卷调查,对夜间光晕及老视眼镜依赖与否行问卷并记录;利用双通道视觉质量分析系统测量客观散射指数、调制传递函数截止频率(modulation transfer function,MTF-cutoff)、斯特列尔比值(strehl ratio,SR)及100%、20%、9%对比度视力(contrast visual acuity,CVA)等指标。结果 三焦组术后近立体视功能明显优于单焦组(P=0.001)。三焦组和单焦组所有术眼术后单眼UDVA较术前均明显提高(均为P<0.05)。三焦组单眼UDVA、UIVA、UNVA均明显优于单焦组(均为P<0.05);三焦组单眼DCDVA与单焦组差异无统计学意义(P>0.05),但DCIVA和DCNVA均明显优于单焦组(均为P<0.01)。三焦组双眼UDVA、UIVA、UNVA均明显优于单焦组(均为P<0.01);三焦组双眼DCDVA与单焦组比较差异无统计学意义(P>0.05),但DCIVA和DCNVA均明显优于单焦组(均为P<0.01)。两组等效球镜度差异无统计学意义(P=0.437)。VF-14量表评分单焦组明显低于三焦组(P=0.000)。90.0%单焦组患者依赖老视眼镜,5.6%三焦组患者依赖老视眼镜,差异有统计学意义(P=0.000);两组眩光发生率差异无统计学意义(P=0.437);两组夜间光晕发生率(单焦组2/20,三焦组7/18)差异有统计学意义(P=0.027)。三焦组和单焦组客观散射指数、斯特列尔比值、调制传递函数截止频率差异均无统计学意义(均为P>0.05)。三焦组100%CVA、20%CVA均好于单焦组(均为P<0.01);9%CVA两组差异无统计学意义(P>0.05)。结论 双眼植入三焦点人工晶状体患者可获得良好的立体视功能和视觉质量,术后满意度高。  相似文献   

6.
目的:比较双焦点人工晶状体(AtLisa tri 809MP)与三焦点人工晶状体(AtLisa tri 839MP)植入术后矫正老视疗效的差异。方法:纳入于我院行白内障超声乳化吸除联合人工晶状体植入术的患者共40例51眼进行分析,其中A组20例25眼植入809MP双焦点人工晶状体,B组20例26眼植入839MP三焦点人工晶状体。收集两组患者术后3mo时远中近视力数值、离焦曲线分析,并通过满意度调查问卷进行统计分析。结果:术后3mo两组裸眼远视力与最佳矫正视力均无差异(P>0.05);中距离视力(80cm)B组显著优于A组(P<0.01);近距离视力改善程度A组、B组无差异(P>0.05)。术后3mo离焦曲线结果A组在0、-3D处形成2个波峰;B组在0、-2.5D处形成2个波峰;两组患者术后均有不同程度的眩光、光晕等表现,但总体满意度较高,视近满意度较高。结论:两种类型人工晶状体均可以为患者提供兼顾远、近的全程视力,术后近距离视物脱镜率高,均可提高良好的近距离视力,三焦点人工晶状体中距离视力更好。  相似文献   

7.
目的:观察飞秒激光白内障手术联合PanOptix三焦点人工晶状体植入术的临床疗效。方法:回顾性研究。选取2020-08/2021-08于我院行飞秒激光白内障手术联合PanOptix三焦点人工晶状体植入术的白内障患者22例26眼,随访至术后3mo,观察手术前后远中近视力、像差、斯特里尔比值(SR)及调制传递函数截止频率(MTF-cutoff)变化情况,绘制术后1mo离焦曲线,评估术后3mo患者视觉质量和满意度。结果:术后1d, 1wk, 1、3mo,纳入患者远中近视力均优于0.1(LogMAR),与术前相比显著改善(均P<0.01)。术后1mo离焦曲线在+0.5~-3.0D之间曲线过渡平缓,视力均优于0.63(小数视力)。术后1d, 1wk全眼总像差、球差均明显低于术前,SR、MTF-cutoff均明显高于术前(均P<0.05)。术后3mo,纳入患者看远中近距离时均无需戴镜,整体满意度高,视觉质量良好。结论:飞秒激光白内障手术联合PanOptix三焦点人工晶状体植入术可使患者获得舒适满意的全程视力。  相似文献   

8.
AIM: To analyze the optical quality after implantation of toric intraocular lens with optical quality analysis system. METHODS: Fifty-two eyes of forty-four patients with regular corneal astigmatism of at least 1.00 D underwent implantation of AcrySof toric intraocular lens, including T3 group 19 eyes, T4 group 18 eyes, T5 group 10 eyes, T6 group 5 eyes. Main outcomes evaluated at 3mo of follow-up, included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual refractive cylinder and intraocular lens (IOL) axis rotation. Objective optical quality were measured using optical quality analysis system (OQAS Ⅱ?, Visiometrics, Spain), included the cutoff frequency of modulation transfer function (MTFcutoff), objective scattering index (OSI), Strehl ratio, optical quality analysis system value (OV) 100%, OV 20% and OV 9% [the optical quality analysis system (OQAS) values at contrasts of 100%, 20%, and 9%]. RESULTS: At 3mo postoperative, the mean UDVA and CDVA was 0.18±0.11 and 0.07±0.08 logMAR; the mean residual refractive cylinder was 0.50±0.29 D; the mean toric IOL axis rotation was 3.62±1.76 degrees, the mean MTFcutoff, OSI, Strehl ratio, OV 100%, OV 20% and OV 9% were 22.862±5.584, 1.80±0.84, 0.155±0.038, 0.76±0.18, 0.77±0.19 and 0.78±0.21. The values of UDVA, CDVA, IOL axis rotation, MTFcutoff, OSI, Strehl ratio, OV100%, OV20% and OV9% depending on the power of the cylinder of the implantation were not significantly different (P>0.05), except the residual refractive cylinder (P<0.05). CONCLUSION: The optical quality analysis system was useful for characterizing the optical quality of AcrySof toric IOL implantation. Implantation of an AcrySof toric IOL is an effective and safe method to correct corneal astigmatism during cataract surgery.  相似文献   

9.
目的:应用OPD-ScanⅢ型像差分析仪评估高度近视合并白内障患者植入三焦点人工晶状体(IOL)术后视觉质量。方法:选取2018-06/2020-12在佛山爱尔眼科医院接受飞秒激光辅助白内障超声乳化手术联合植入三焦点IOL的高度近视白内障患者32例38眼,比较术前,术后1wk,3mo裸眼远视力(UCDVA)、中距离视力(UCIVA)、近距离视力(UCNVA);术前,术后1wk,3mo进行OPD-ScanⅢ型像差分析仪检查。结果:术前,术后1wk,3mo UCDVA、UCIVA、UCNVA比较均有差异(P<0.05),术后3mo人工晶状体偏心距为0.12(0.08~0.15)mm,轴位为(212.68±90.45)°。术前,术后1wk,3mo球差比较有差异(P<0.05)。术前,术后1wk,3mo斯特列尔比(SR)、调制传递函数(MTF)曲线中4mm面积比(AR)比较均有差异(P<0.001)。术后1wk,3mo SR比术前提升,术后1wk,3mo AR比术前提升(均P<0.001)。术后3mo SR与球差、三叶草呈负相关(rs=-0.420、-0.418,均P<0.01);术后3mo AR与三叶草呈负相关(rs=-0.400,P<0.05)。结论:高度近视合并白内障患者植入三焦点IOL术后全程视力提高,OPD-ScanⅢ型像差分析仪结果显示术后IOL居中性良好,视觉质量良好。  相似文献   

10.
AIM: To evaluate the clinical outcomes in terms of vision across distances (near, intermediate, and far), contrast sensitivity and subjective patient satisfaction after femtosecond laser-assisted cataract surgery (FLACS) with implantation of an extended range of vision (ERV) intraocular lens (IOL). METHODS: Forty patients (55 eyes) undergoing bilateral or monocular FLACS with implantation of the ERV IOL TECNIS Symfony (Johnson & Johnson Vision) were enrolled. Uncorrected distance (UDVA), intermediate (UIVA) and near visual acuities (UNVA) were evaluated at 3mo after surgery, as well the defocus curve, contrast sensitivity, patient satisfaction and spectacle independence. RESULTS: No severe complications occurred. All eyes showed a central position of the IOL in the capsular bag without tilting at 3mo after surgery. 3mo postoperative mean logMAR visual acuity at 5 m, 67 cm and 40 cm were -0.04 ±0.08, -0.17±0.22, 0.37±0.17, respectively. All patients obtained satisfactory UDVA and UIVA, as well as functional UNVA, meeting the needs of daily life. Spectacle independence rate was 94.55%. Contrast sensitivity results did not differ from those obtained with monofocal aspheric lenses. Likewise, no moderate and severe photic phenomena were reported. Mean patient satisfaction scores with distance, intermediate and near vision were 9.0, 9.0, and 7.0, respectively. CONCLUSION: FLACS with implantation of the ERV IOL TECNIS Symfony provides a successful visual restoration at far, intermediate distance and a functional-range near vision acuity, with minimal level of disturbing photic phenomena, and high rates of spectacle independence and patient satisfaction.  相似文献   

11.
目的 评价非球面多焦点散光矫正型人工晶状体植入术后患者的视觉质量。方法 前瞻性对照研究。选取2013年1月至2013年12月在天津医科大学眼科医院行超声乳化白内障吸出术的单纯年龄相关性白内障患者130例(150眼)分为三组,每组50眼。其中,术前规则角膜散光0.5~2.5D患者植入非球面多焦点散光矫正型人工晶状体为试验组(ART组);术前顺规角膜散光<1D,逆规角膜散光<0.75D患者植入非球面多焦点人工晶状体为对照组1(Restor组);术前规则角膜散光1.0~3.0D患者植入非球面散光矫正型人工晶状体为对照组2(Toric组)。术后1d、1周、1个月、3个月用OQAS视觉质量分析仪检查三组患者的OQAS参数、对比敏感度、裸眼远视力、最佳矫正远视力,并进行脱镜率和患者满意度调查,绘制三组患者的离焦曲线;检查ART组和Restor组的最佳近视力、60cm中距离视力;检查ART组和Toric组的轴位旋转度。结果 三组裸眼远视力及最佳矫正远视力差异无统计学意义(F=0.661,P=0.518;F=0.013,P=0.987);ART组与Restor组中距离视力及最佳近视力差异均无统计学意义(t=-0.796,P=0.428;t=-0.885,P=0.378);OQAS参数检查发现:三组的客观散射指数、调制传递函数截止频率值、OV100%、OV20%、OV9%差异均无统计学意义(均为P>0.05);三组的斯特列尔比值、对比敏感度结果比较,差异均有统计学意义(均为P<0.05),其中ART组与Restor组差异均无统计学意义(均为P>0.05);术后3个月轴位旋转度,ART组与Toric组差异无统计学意义(t=1.036,P=0.303);ART组与Restor组脱镜率分别为90%和88%,高于Tor-ic组的12%,三组均未发现明显视觉干扰现象。结论 非球面多焦点散光矫正型人工晶状体在有效矫正角膜散光的基础上,可以提供一个良好的全程视力,提高了患者脱镜率。  相似文献   

12.
AIM: To compare a trifocal intraocular lens (IOL) and a bifocal IOL implantation in improving visual function after cataract surgery. METHODS: Eligible literatures were systematically searched through EMBSE and PubMed databases. The inclusion criteria were prospective comparative clinical trials on cataract surgery comparing trifocal IOL with bifocal IOL implantation that assessed visual acuity, contrast sensitivity and subjective vision quality. The effects were computed as standardized mean differences and pooled using fixed-effect or random-effect models. RESULTS: Four prospective randomized controlled trials (RCTs) and five cohorts provided data and were included by a systematic review, comprising 265 eyes implanted with trifocal IOLs and 264 eyes implanted with bifocal IOLs. Monocular distance visual acuity (VA) showed a statistically significant but small difference that favored trifocal IOLs (MD=-0.06; 95%CI, -0.10 to -0.02; Z=2.90, P=0.004 for UDVA and MD=-0.02; 95%CI, -0.03 to -0.00; Z=2.02, P=0.04 for CDVA), but the data did not suggest that the effect of trifocal IOL implantation would clinically outperform bifocal IOL implantation. There was no significant difference in monocular near VA (MD=-0.01; 95% CI, -0.07 to 0.04; Z=0.42, P=0.68 for UNVA, and MD=-0.01; 95% CI, -0.06 to 0.03; Z=0.55, P=0.58 for DCNVA) or refraction between two groups. Contrast sensitivity and subjective visual quality had no conclusive results. CONCLUSION: All results indicate that trifocal IOL and bifocal IOL had similar levels of monocular distance and near visual acuities. Besides, contrast sensitivity and subjective visual quality have no conclusive results.  相似文献   

13.
目的:观察白内障超声乳化联合旋转非对称折射型多焦点人工晶状体(IOL)植入术后患者的早期 效果。方法:前瞻性自身前后对照研究。选择2017年1-12月在武汉爱尔眼科医院行白内障超声乳化联合旋转非对称折射型多焦点IOL植入的患者36例(40眼),术后随访3个月。分别观察裸眼远、中、近视力(LogMAR),矫正远视力(LogMAR),术后等效球镜度(SE),离焦曲线,调制传递函数(MTF),眼内高阶像差,并统计患者术后视功能指数量表评分及脱镜率。数据采用配对t检验和非参数Wilcoxon配对秩和检验。结果:术后3个月裸眼远、中、近视力及矫正远视力均较术前增加(P<0.05),72%裸眼远视力优于0.1,98%矫正远视力优于0.1;88%术后SE在±1.0 D以内;离焦曲线在0.0 D及-2.5 D具有峰值,+1.0~-4.0 D屈光范围内视力均优于0.25。术后3 mm瞳孔直径下MTF数值均较术前提高(P<0.05),眼内总像差、垂直彗差及垂直三叶草较术前增加(P<0.05)。患者术后3个月视功能指数量表得分为1.0(0.0,2.0)。92%的患者看远、看近均可完全脱镜。结论:非对称区域折射型多焦点IOL能提供令人满意的远、近视力,亦能保持较大范围的中距离视力,患者术后具有较好的视觉质量及较高的生活质量。  相似文献   

14.

目的:通过观察飞秒激光辅助的白内障手术联合TECNIS Symfony连续视程人工晶状体植入术后远中近全程视力、对比敏感度,主观满意度,综合评价TECNIS Symfony人工晶状体植入术后患者的视觉质量。

方法:收集我院目前已实施40例55眼飞秒激光辅助白内障联合TECNIS Symfony 连续视程人工晶状体植入术资料,检测术后3mo裸眼远视力(5 m)、中视力(67 cm)及近视力(40 cm),绘制离焦曲线,根据多焦晶体满意度调查表并计算脱镜率。

结果:所有患者术中术后无严重并发症发生。术后3mo,所有患者人工晶状体位置居中,无明显偏位或倾斜。术后3mo, 5 m、67 cm、40 cm平均裸眼LogMAR视力分别为:-0.04±0.08, -0.17±0.22, 0.37±0.17。总体脱镜率95%。不同空间频率的对比敏感度较普通单焦非球面人工晶状体无明显下降。无中等或严重光学干扰现象发生。远中近各功能区满意度评分分别为9.0,9.0,7.0分。

结论:飞秒激光辅助的白内障手术联合TECNIS Symfony连续视程人工晶状体植入术后可获得满意的远中裸眼视力和基本满足日常生活的近视力,术后光学干扰少,脱镜率高,患者满意度高。  相似文献   


15.
目的 对比中央带孔型及传统眼内接触镜(intraocular contact lens,ICL)矫正高度近视术后视觉质量.方法 选择行传统ICL植入术的高度近视患者11例(21眼)作为传统组,另外选择行带孔型ICL植入术的高度近视患者12例(20眼)作为带孔型组.术后6个月分别行裂隙灯显微镜检查眼前节,标准对数视力袁检查裸眼视力(uncorrected visual acuity,UCVA)、最佳矫正视力(best corrected visual acuity,BCVA),自动验光仪测量手术前后等效球镜度数(spherical equivalent,SE)、散光度数.OQAS视觉质量检查包括客观散射指数(objective scattering index,OSI)、调制传递函数(modulation transfer function,MTF)、斯特列尔比(stryrby,SR)、不同对比度下OQAS值(OV100%、OV20%、OV9%).结果 两组患者UCVA (logMAR)、BCVA(logMAR)、SE及散光度数术后6个月均较术前减小,差异均有统计学意义(均为P<0.05);术前及术后6个月两组间UCVA、BCVA、SE及散光度数比较,差异均无统计学意义(均为P>0.05).带孔型组和传统组患者植入术后6个月OQAS视觉质量参数MTFcutoff、SR、和OV100%、OV20%、OV9%值均较术前增高,差异均有统计学意义(均为P<0.05).带孔型组和传统组患者植入术后6个月OSI均较术前略降低,但差异均无统计学意义(均为P >0.05).对比术后6个月带孔型组和传统组患者OQAS视觉质量参数OSI、MTFcutoff、SR、和OV100%、OV20%、OV9%值两组间差异均无统计学意义(均为P>0.05).结论 两种类型ICL矫正高度近视均是安全有效的,中央带孔型ICL可以提供和传统ICL接近的视觉质量.  相似文献   

16.

目的:观察飞秒激光辅助白内障手术联合三焦点人工晶状体(IOL)植入术后的临床疗效。

方法:回顾性自身前后对照研究。选择2016-09/2017-11就诊于山西省眼科医院植入三焦点IOL的白内障患者42例59眼,随访至术后6mo,分别观察术前、术后1wk,1、3、 6mo单眼裸眼远、中、近距离视力(LogMAR)、离焦曲线、屈光稳定性、高阶像差、患者满意度和脱镜率。

结果:所有患者在术后各随访时间点远、中、近距离均可获得优于0.1LogMAR的良好视力,术后各距离视力与术前相比显著提高(P<0.05)。术后6mo离焦曲线在0~-2.5D之间曲线过渡平缓,术眼达到优于0.8的视力水平。术后6mo,63%(37眼)的患眼SE位于±0.25D之间,88%(52眼)的患眼SE则位于±0.50D之间。术后各时期全眼的总高阶像差、彗差、球差、三叶草像差明显低于术前(P<0.05)。

结论:飞秒激光辅助白内障手术联合三焦点IOL植入术可以为患者提供舒适自然的全程视力,实现真正的脱镜,患者术后满意度高。  相似文献   


17.
AIM: To compare a trifocal intraocular lens (IOL) and a bifocal IOL implantation in improving visual function after cataract surgery. METHODS: Eligible literatures were systematically searched through EMBASE and PubMed databases. The inclusion criteria were prospective comparative clinical trials on cataract surgery comparing trifocal IOL with bifocal IOL implantation that assessed visual acuity, contrast sensitivity and subjective vision quality. The effects were computed as standardized mean differences and pooled using fixed-effect or random-effect models. RESULTS: Four prospective randomized controlled trials (RCTs) and five cohorts provided data were included by a systematic review, comprising 265 eyes implanted with trifocal IOLs and 264 eyes implanted with bifocal IOLs. Monocular distance visual acuity (VA) showed a statistically significant but small difference that favored trifocal IOLs (MD=-0.06; 95%CI, -0.10 to -0.02; Z=2.90, P=0.004 for uncorrected distance VA, and MD= -0.02; 95%CI, -0.03 to -0.00; Z=2.02, P=0.04 for corrected distance VA), but the data did not suggest that the effect of trifocal IOL implantation would clinically outperform bifocal IOL implantation. There was no significant difference in monocular near VA (MD=-0.01; 95%CI, -0.07 to 0.04; Z=0.42, P=0.68 for distance-corrected near VA, and MD=-0.01; 95%CI, -0.06 to 0.03; Z=0.55, P=0.58 for corrected near VA) or refraction between two groups. Contrast sensitivity and subjective visual quality had no conclusive results. CONCLUSION: All results indicate that trifocal IOL and bifocal IOL had similar levels of monocular distance and near VA.  相似文献   

18.
鲁铭  朱晶  肖泽锋 《国际眼科杂志》2021,21(7):1166-1169

目的:比较Tecnis Symfony连续视程人工晶状体与Zeiss三焦点人工晶状体(At Lisa tri 839MP)植入术后患者视觉质量的差异。

方法:选取2019-01/2020-12于我院行白内障超声乳化吸除联合人工晶状体植入术的患者42例53眼,其中A组22例29眼植入Tecnis Symfony连续视程人工晶状体,B组20例24眼植入Zeiss三焦点人工晶状体。观察两组患者术后3mo时远中近视力,绘制离焦曲线,并评估生活质量,记录并发症发生情况。

结果:术后3mo,两组患者视力均明显改善,两组患者裸眼远(5m)、中(80cm)距离视力及最佳矫正远距离视力(5m)无差异(均P>0.05),但B组患者裸眼中(60cm)、近(40cm)距离视力优于A组(均P<0.05)。术后3mo绘制离焦曲线示A组在+1.0~-2.0D段跨度平稳形成平台期; B组在0、-2.5D处形成两个波峰; 0D处两组远视力无显著差异(P>0.05),-2.5、-3.5D处B组近视力显著优于A组(均P<0.01)。两组患者术后脱镜率均在90%以上,均出现不同程度眩光、光晕等光学现象,但生活质量总体满意度较高,A组阅读速度明显高于B组,且夜间视物满意度较高(均P<0.05)。

结论:两种类型人工晶状体植入术后脱镜率均在90%以上,可为患者提供兼顾远、中、近的全程视力,Symfony连续视程人工晶状体植入术后流畅阅读及夜间视物满意度较高; Zeiss三焦点人工晶状体植入术后近距离视力更好,更适合近距离工作者。  相似文献   


19.
目的 比较不同人工晶状体植入对年龄相关性白内障患者客观视觉质量及视觉相关生活质量的影响及相互关系。方法 采用前瞻性非随机对照研究设计,收集2018年1月至8月在西南医科大学附属医院眼科行白内障超声乳化吸出联合人工晶状体植入术的年龄相关性白内障患者66例(90眼),其中植入单焦点人工晶状体34例(52眼)患者为单焦点组,植入衍射型多焦点人工晶状体32例(38眼)患者为多焦点组。测量2组患者术前及术后3个月术眼裸眼远近视力(uncorrected distance visual acuity,UCDVA;uncorrected near visual acuity,UCNVA),最佳矫正远、近视力(best-corrected distance visual acuity,BCDVA;best-corrected near visual acuity,BCNVA),采用中文版25项美国国家眼科研究所视觉功能问卷调查(25-item national eye institute visual function questionnaire,NEI-VFQ-25)评估患者手术前后的视觉相关生活质量,结合双通道视觉质量分析仪OQAS II对患者术眼手术前后客观散射指数(objective scatter index,OSI)、调制传递函数截止频率(modulation transfer function cut off,MTF cut off)、斯特列尔比(strehl ratio,SR)、对比度为100%、20%及9%的OQAS值(OV100、OV20、OV9)以及伪调节力进行测量。结果 两组患者术后UCDVA及BCDVA均较术前明显提高(t=-27.763、-16.772、-13.429、-12.936,均为P<0.01),多焦点组患者术后UCNVA及BCNVA均较术前明显提高(均为P<0.05),多焦点组术后UCNVA较单焦点组高(t=-6.364,P<0.01),2组间术后UCDVA、BCDVA、BCNVA差异均无统计学意义(均为P>0.05)。多焦点组术后总体视觉、近距离工作评分均较单焦点组好(均为P<0.05),单焦点组术后色彩视觉评分较多焦点组好(P<0.05),2组患者术后的独立性及精神健康均较术前改善(均为P<0.05),2组间术后差异均无统计学意义(均为P>0.05)。多焦点组术后OSI、调节幅度较单焦点组均高(均为P<0.05),MTF cut off、OV20、OV9较单焦点组均低(均为P<0.05)。结论 植入单焦点人工晶状体及衍射型多焦点人工晶状体均能有效改善年龄相关性白内障患者的客观视觉质量,从而明显改善患者术后视觉相关生活质量。  相似文献   

20.

目的:通过双通道客观视觉质量分析系统Ⅱ(OQAS Ⅱ)评价有晶状体眼后房型人工晶状体(ICL)植入术对高度近视的临床疗效。

方法:选取2017-12/2018-12安徽医科大学第一附属医院收治的高度近视患者26例52眼,所有患者均行ICL植入术。随访获取所有患者术前BCVA以及术前和术后1wk,1、3mo的UCVA、客观散射指数(OSI)、调制传递函数(MTF)、斯特列尔比(SR)和100%、20%及9%的模拟对比度视力(Predicted VA)等一系列参数。

结果:与术前BCVA相比,术后1wk,1、3mo UCVA情况均优于术前且日渐改善(P<0.01)。与术前OSI、MTF、SR和Predicted VA 100%、20%及9%相比,术后1wk,1、3mo情况均好转(P<0.01)。

结论:ICL植入术能够有效地矫正高度近视,提高裸眼视力。通过OQAS Ⅱ分析,ICL植入术后OSI比术前减小,术后的MTF、SR和Predicted VA 100%、20%及9%比术前均有提高,高度近视患者视觉质量得到良好的改善。  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号