1.
PURPOSE: To evaluate the efficacy, predictability, and safety of custom laser in situ keratomileusis (LASIK) using the Visx wavefront platform CustomVue for the treatment of myopia and myopic astigmatism. SETTING: Stanford University Eye Laser Center, Stanford, California, USA. METHODS: This retrospective analysis was of the initial 140 eyes of 78 patients treated consecutively with LASIK for myopia using the Visx Star S4 excimer laser. Primary outcome variables, including uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, and complications, were evaluated at 1 week and 1 and 3 months. Vector analysis was performed on eyes that received astigmatic correction. RESULTS: Mean preoperative spherical equivalent (SE) was reduced from -3.89 diopters +/- 1.48 (SD) to an SE of -0.21 +/- 0.36 D at 1 month and -0.28 +/- 0.36 D at 3 months (P < .001). At 1 and 3 months, UCVA was 20/20 or better in 84.3% and 87.9%, respectively. Eighty-six percent of eyes at 1 month and 81.4% of eyes at 3 months were within +/-0.5 D of emmetropia. No eyes lost more than 2 lines of BSCVA. Vector analysis yielded an index of success of 0.39, indicating a 61% success rate in achieving the astigmatic surgical correction at 3 months. The preoperative root-mean-square value of 0.28 +/- 0.08 microm increased slightly to 0.33 +/- 0.11 microm at 1 month and 0.34 +/- 0.11 microm at 3 months. CONCLUSION: Wavefront-guided LASIK using the Visx CustomVue system was effective, predictable, and safe for correction of low to moderate myopic refractive error.  相似文献   

2.
《Ophthalmology》1999,106(8):1481-1489
ObjectiveTo assess the safety and effectiveness of the Autonomous Technologies Corporation LADARVision excimer laser system for photorefractive keratectomy correction of myopia and astigmatism.DesignA multicenter, prospective, noncomparative case series.ParticipantsThe cohort consisted of 467 eyes corrected for spherical myopia and 211 eyes corrected for myopia with astigmatism.InterventionTreatments were performed at six sites in the United States using a 6-mm ablation zone for spherical myopes and a 5.5-mm zone with a 1.0-mm blend for astigmats.Main outcome measuresVisual acuity, subjective refraction, corneal haze, intraocular pressure, complications, adverse reactions, patient satisfaction, and corneal endothelial changes.ResultsTwelve-month follow-up was available on 414 spherical eyes and 175 astigmatic eyes. The results for spherical eyes with correction between −1 and −5.99 diopters (D) were: uncorrected visual acuity (UCVA) of 20/40 or better achieved by 98.1%, 20/20 or better by 72%, 1.8% lost 2 lines and 0.3% lost greater than 2 lines of best spectacle-corrected visual acuity (BSCVA); 76.4% were within 0.50 D of the target correction and 94.4% were within 1.00 D. The results for myopia with astigmatism with spherical equivalent correction between −1 and −5.99 D were: UCVA of 20/40 or better in 97.4%, 20/20 or better in 61.7%, 2.5% lost 2 lines and no eyes lost greater than 2 lines BSCVA; 73.9% were within 0.50 D of the target correction and 95% were within 1.00 D. For spherical myopes combined with myopic astigmats corrected for 6 to 10 D, results were: UCVA of 20/40 or better in 93.4%, 20/20 or better in 61.2%, 2.3% lost 2 lines and no eyes lost greater than 2 lines of BSCVA; 67.2% were within 0.50 D of the desired correction and 87.8% were within 1.00 D. Refractive stability was achieved between 3 and 6 months for the spherical and astigmatic groups. No eyes had corneal haze graded as moderate or greater, and there was no significant decrease in endothelial cell density.ConclusionsPatients treated for 1 to 10 D of spherical equivalent myopia, with or without astigmatism, showed early refractive stability, excellent UCVA, no significant loss of BSCVA, no loss of endothelial cell density, and very low levels of corneal haze to 12 months after surgery.  相似文献   

3.
OBJECTIVE: To assess the safety and effectiveness of the Summit Autonomous LADARVision active tracking narrow beam excimer laser system for laser in situ keratomileusis (LASIK) correction of myopia and astigmatism. DESIGN: A multicenter, prospective noncomparative case series. PARTICIPANTS: This cohort consisted of 177 eyes corrected for spherical myopia up to -11 diopters (D) and 170 eyes corrected for myopia up to -11 D spherical equivalent with astigmatism up to -5 D. INTERVENTION: Treatments were performed at four sites in the United States using a 6-mm optic zone for spherical myopes and a 5.5-mm optic zone with a 1-mm blend for astigmats. MAIN OUTCOME MEASURES: Visual acuity, subjective refraction, vector analysis, subject satisfaction, intraocular pressure, complications, and adverse reactions. RESULTS: Six-month follow-up was available on 157 spherical eyes and 113 astigmatic eyes. For spherical myopes, uncorrected visual acuity (UCVA) was 20/20 or better in 60.5%, 20/25 or better in 80.3%, and 20/40 or better in 93.9%. The mean spherical equivalent was -0.29 +/- 0.45 D with 75.2% +/- 0.50 D and 94.9% +/- 1.00 D of intended. A loss of two lines of best spectacle-corrected visual acuity (BSCVA) occurred in 0.6%, and no eyes lost greater than two lines of BSCVA. For astigmatic myopes, UCVA was 20/20 or better in 52.0%, 20/25 or better in 74.5%, and 20/40 or better in 94.1%. The mean spherical equivalent was -0.23 +/- 0.49 D with 75.2% +/- 0.50 D and 95.6% +/- 1.00 D of intended. A loss of two lines of BSCVA occurred in 0.9%, and no eyes lost greater than two lines of BSCVA. Vector analysis showed that 99% of the intended cylinder was corrected on average with a mean angle of error of 4.2 degrees. Refractive stability was achieved between 1 and 3 months in 97.5% of spherical eyes and 99.4% of astigmatic eyes and confirmed between 3 and 6 months in 100% of both spherical and astigmatic eyes. CONCLUSIONS: Eyes treated for myopia up to -11 D of spherical equivalent with or without astigmatism up to -5 D show early refractive stability, good UCVA outcomes, no significant loss of BSCVA, accurate correction of astigmatism, and slight undercorrection without a change from the photorefractive keratectomy algorithm and with a single treatment.  相似文献   

4.
PURPOSE: To evaluate the safety, efficacy, predictability, and visual results of laser in situ keratomileusis (LASIK) using the Bausch & Lomb Technolas(R) 217 scanning-spot laser for the treatment of myopia and compound myopic astigmatism. SETTING: Stanford Eye Laser Center, Stanford, California, USA. METHODS: In a prospective study, 110 eyes of 58 patients with a mean spherical equivalent (SE) of -4.87 diopters (D) +/- 2.5 (SD) (range -1.0 to -11.4 D) had LASIK for myopia and compound myopic astigmatism using the Technolas 217 scanning-spot laser. The primary outcome variables included preoperative and postoperative best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity (UCVA), achieved versus attempted correction, vector analysis of astigmatism, and complications. RESULTS: One hundred ten eyes were available for analysis at 3 months. The mean SE refraction was reduced 95% (mean -0.23 +/- 0.4 D), and astigmatism was reduced 70% (mean 0.28 +/- 0.3 D). One day postoperatively, 100% of eyes had a UCVA of 20/40 or better, 96% had 20/25 or better, 77% had 20/20 or better, and 39% had 20/15 or better. At the 3-month examination, 100% of eyes had a UCVA of 20/40 or better, 95% had 20/25 or better, 83% had 20/20 or better, and 48% had 20/15 or better. Ninety percent of eyes were within +/-0.5 D of emmetropia. No eye lost 2 or more lines of BSCVA. CONCLUSIONS: The Technolas 217 scanning-spot laser produced excellent postoperative UCVA and BSCVA. It was predictable, safe, and effective for the treatment of myopia and compound myopic astigmatism. Long-term follow-up is needed to assess the stability of the procedure.  相似文献   

5.
PURPOSE: To evaluate the visual and refractive results of conventional (non-wavefront) laser in situ keratomileusis (LASIK) for treatment of myopia and myopic astigmatism using the Alcon LADARVision 4000 excimer laser system and nomogram adjustment techniques. METHODS: A retrospective analysis of 499 eyes that had LASIK for myopia and myopic astigmatism was performed. Preoperative manifest spherical equivalent refraction ranged from -0.43 to -6.00 D and preoperative astigmatism ranged from 0 to -4.75 D. Patients were evaluated during 3 months following surgery. RESULTS: One month after surgery, 72% of eyes examined (298/415 eyes) had uncorrected visual acuity (UCVA) of 20/20 or better. Three months after surgery, 83% of eyes examined (216/261 eyes) had UCVA of 20/20 or better. One and three months after surgery, 82% and 83% of eyes, respectively, were within +/-0.50 D of attempted correction; 97% of eyes were within +/-1.00 D at both 1 and 3 months. No eye lost more than 1 line of best spectacle-corrected visual acuity (BSCVA) at 3 months after surgery. At the 3-month examination, 83% of eyes had UCVA better than or equal to preoperative BSCVA. CONCLUSIONS: Conventional LASIK to correct myopia and myopic astigmatism was safe and effective using the Alcon LADARVision 4000 excimer laser system. Outcomes were substantially improved throughout development of an accurate nomogram, derived from continually updated regression analysis of previous refractive results.  相似文献   

6.
PURPOSE: To evaluate the safety and efficacy of laser-assisted subepithelial keratectomy (LASEK) for the treatment of low to high myopia and astigmatism. SETTING: Solo private practice, Mountain View, California, USA. METHODS: Laser-assisted subepithelial keratectomy was performed in 146 eyes of 83 consecutive patients with myopia or myopic astigmatism using a VISX Star S2 excimer laser (72 eyes) or a Nidek EC-5000 excimer laser (74 eyes). The mean preoperative myopic spherical equivalent was -5.32 diopters (D) (range -1.25 to -14.38 D). Data were collected prospectively with a follow-up of 1 to 12 months. Outcome measurements included uncorrected visual acuity (UCVA), manifest refraction, best spectacle-corrected visual acuity (BSCVA), corneal haze, and complications. RESULTS: After 6 and 12 months, no eye lost 2 or more lines of BSCVA. After 6 months, the UCVA was 20/20 in 57% of eyes and 20/40 or better in 96%. After 12 months, it was 20/20 in 56% of eyes and 20/40 or better in 96%. No eye developed corneal haze that affected visual acuity. There were no serious or vision-threatening complications. CONCLUSIONS: Laser-assisted subepithelial keratectomy was safe and effective in treating a wide range of myopia and astigmatism. The potential advantages of LASEK over laser in situ keratomileusis (LASIK) include the elimination of stromal flap complications and greater choice in patient selection. The disadvantages include varying degrees of pain for 2 days and blurry vision for several days postoperatively.  相似文献   

7.
PURPOSE: To compare visual function, safety, and higher-order aberrations (HOAs) after wavefront-guided laser in situ keratomileusis (LASIK) with the LadarVision CustomCornea (Alcon Laboratories, Inc.) and Star S4 CustomVue (Visx) laser systems. SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: Seventy-eight eyes of 39 patients with myopia with or without astigmatism were randomized for LASIK treatment in 1 eye with the CustomCornea laser; the other eye was treated with the CustomVue laser. Patients were followed for 6 months after surgery. The primary outcome measures were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, and changes in HOAs. RESULTS: At 6 months, the mean logarithm of the minimum angle of resolution (logMAR) UCVA was -0.0135 +/- 0.07 (SD) in the CustomVue group and 0.0417 +/- 0.12 in the CustomCornea group (P = .023). Eighty-eight percent of eyes in the CustomVue group had 20/20 or better UCVA compared with 67% in the CustomCornea group (P<.02). At 6 months, 91% of eyes in the CustomVue group and 79% in the CustomCornea group were within +/-0.50 diopter (D) of emmetropia (P<.1); 88% and 50%, respectively, were within +/-0.25 D (P<.001). Both platforms led to a small increase in total HOAs. The CustomVue system reduced trefoil and induced less of an increase in total HOAs, whereas the CustomCornea platform increased trefoil but induced less of an increase in spherical aberrations and coma. CONCLUSIONS: Both laser systems were effective, safe, and predictable. Wavefront-guided LASIK with the CustomVue system resulted in better visual acuity, with more eyes having 20/20 acuity than in the CustomCornea group.  相似文献   

8.
LASIK for myopia with the Zeiss meditec MEL 80   总被引:3,自引:0,他引:3  
PURPOSE: To prospectively evaluate a new high-speed, small spot-scanner laser for the correction of myopia and myopic astigmatism. METHODS: Seventy-six consecutive eyes with myopia and myopic astigmatism between -1.00 and -8.25 diopters (D) and up to -2.75 D astigmatism underwent LASIK treatment using the MEL 80 laser (Carl Zeiss Meditec, Jena, Germany). Parameters evaluated were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), residual refractive error, regression of correction, and aberrometry. RESULTS: Mean preoperative BSCVA was 20/20, which improved to 20/18 postoperatively. Postoperative UCVA was 20/20 at 1 month and 20/18 at 1 year. Uncorrected visual acuity > or = 20/20 was achieved in 58 (83%) of 70 eyes at 1 month and in 60 (88%) of 68 eyes at 1 year. The average refractive error before LASIK was -4.41 +/- 1.98 D. The mean residual refractive error was 0.14 +/- 0.31 D at 1 month and 0.13 +/- 0.30 D at 1 year. At 1-month and 1-year follow-up, respectively, 66 (94%) of 70 eyes and 65 (96%) of 68 eyes were within +/- 0.50 D of intended refractive correction. No eye lost two lines. At 1 month 17% of eyes and at 1 year 13% of eyes gained two lines or more. Between 1-month and 1-year follow-up, 100% of eyes were stable. Mean root-mean-square high order aberration changed from 0.20 microm preoperatively to 0.28 microm postoperatively. CONCLUSIONS: The MEL 80 is effective and safe in the treatment of myopia and myopic astigmatism.  相似文献   

9.
Wavefront-supported photorefractive keratectomy: 12-month follow-up   总被引:2,自引:0,他引:2  
PURPOSE: To evaluate safety, efficacy, predictability, and stability of wavefront-supported photorefractive keratectomy (PRK) for correction of myopia and myopic astigmatism, with 12-month follow-up. METHODS: Thirty eyes of 23 patients with myopia less than -8.00 D (mean -3.76 +/- 1.90 D) and cylinder less than -3.50 D (mean -0.81 +/- 0.71 D) were selected. Aberrometry measurements were taken with the Asclepion aberrometer in order to perform customized wavefront-supported PRK. Eyes were treated with the Asclepion MEL 70 excimer laser and were followed for 12 months. RESULTS: UCVA of 20/16 or better was achieved by 47% (14 eyes) at 1 month, 67% (20 eyes) at 3 months, 77% (23 eyes) at 6 months, 90% (27 eyes) at 9 months, and 83% (25 eyes) after 1 year. No eye lost more than 1 line of BSCVA at 3, 6, 9, or 12 months. Two eyes (7%) gained more than 2 lines 1 month postoperatively, and 13% (4 eyes) gained more than 2 lines at 6, 9, and 12 months postoperatively. BSCVA of 20/10 or better was achieved in nine eyes (30%) at 1 and 12 months. Visual acuity under low contrast at 3 and 12 months after PRK was unchanged in 87% (26 eyes). Visual acuity under glare remained unchanged at 3 months after PRK in 86% (26 eyes) and at 12 months in 83% (25 eyes). CONCLUSION: Excimer laser wavefront-supported PRK with the Asclepion MEL 70 laser was safe and effective for the treatment of myopia and myopic astigmatism. Daylight visual acuity and mesopic visual acuity outcomes remained stable over 1 year.  相似文献   

10.
Kapadia MS  Wilson SE 《Cornea》2000,19(2):180-184
PURPOSE: To retrospectively evaluate the results of myopic photorefractive keratectomy (PRK) for different levels of intended correction, including analysis of loss of best spectacle-corrected visual acuity. METHODS: Four hundred seventy-five consecutive eyes with 1 year of follow-up that had PRK for the correction of 1-7 diopters (D) of myopia by using the Summit SVS Apex excimer laser. Three hundred forty-eight eyes were examined at 1 year. This study was confined to the 236 eyes with 1 year of follow-up that had PRK without astigmatic keratotomy. Eyes also were analyzed according to the range of attempted correction (0-3 D, low; 3.1-6D, moderate; and > or =6.1 D, high moderate). Manifest refraction, uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), surface regularity index (SRI), and surface asymmetry index (SAI) were evaluated for each group. RESULTS: One year after PRK, 91% of all eyes were within 1 diopter and 73% of eyes were within 0.5 diopter of emmetropia. Uncorrected visual acuity was 20/25 or better in 79% and 20/40 or better in 96% of eyes. Two lines of BSCVA were lost in only 0.4% of eyes (one of 236). No eye lost >2 lines of BSCVA, and 30% gained one line. Mean SRI and SAI were increased as compared with preoperative values, but were within the normal range for our patient population (ranges, 0.2-1.0 and 0.1-0.7, respectively). UCVA, BSCVA, and predictability decreased, whereas SAI and SRI increased, with increasing attempted correction. CONCLUSION: PRK effectively reduced myopia in all eyes with 12 months' follow-up. Predictability tended to decrease with increasing attempted correction, even for low to moderate myopia. PRK may induce mild surface asymmetry and irregularity, and these alterations tend to increase with higher attempted correction. Fewer than 0.5% of eyes lost > or =2 lines of best-corrected visual acuity.  相似文献   

11.
PURPOSE: To evaluate the efficacy, predictability, stability, and safety of the Meditec MEL 70G-Scan flying spot excimer laser. METHODS: One hundred thirty myopic eyes were treated with the Aesculap Meditec Mel 70G-Scan ArF flying spot excimer laser with photorefractive keratectomy (PRK). Patient groups: low myopia (Group 1) from -1.50 to -6.00 D (90 eyes), medium myopia (Group 2) from -6.10 to -9.00 D (31 eyes), high myopia (Group 3) from -9.10 to -14.00 D (9 eyes). RESULTS: At 12 months in the low myopia group, uncorrected visual acuity (UCVA) of 20/40 or better was achieved in 95.5% (86 eyes), 20/20 or better in 77.7% (70 eyes); 2.2% (two eyes) lost two or more lines of best spectacle-corrected visual acuity (BSCVA); 73.3% (66 eyes) were within +/-0.50 D of the target correction and 98.8% (89 eyes) were within +/-1.00 D. In the medium myopia group, UCVA of 20/40 or better was achieved in 74.2% (23 eyes), 20/20 or better in 25.8% (eight eyes); 3.2% (one eye) lost two lines, 61% (19 eyes) were within +/-0.50 D of desired correction and 83.8% (26 eyes) were within +/-1.00 D. In the high myopia group, UCVA of 20/40 or better was achieved in 22.2% (two eyes); 20/25 or better in 11.1% (one eye); none of the eyes achieved 20/20 UCVA; 22.2% (two eyes) lost two lines of BSCVA; 44.4% (four eyes) were within +/-0.50 D and 66.6% (six eyes) were within +/-1.00 D of the target correction. Refractive stability was achieved between 3 and 6 months. Increased intraocular pressure was detected overall in 7.69%. CONCLUSIONS: The results of predictability, safety, and efficacy in low and medium myopia with the Meditec MEL 70G-Scan flying spot excimer laser were good, but poorer predictability, regression, and a significant loss of BSCVA were observed in the high myopia group.  相似文献   

12.
OBJECTIVE: To determine the safety, efficacy, and predictability of the Autonomous scanning and tracking laser for the correction of myopia and myopic astigmatism with laser in situ keratomileusis (LASIK) procedure. DESIGN: Retrospective, noncomparative case series. PARTICIPANTS: The first 129 consecutive eyes with up to -13.00 diopters (D) of myopia and -5.00 D of astigmatism. INTERVENTION: Myopic tracker-assisted LASIK (T-LASIK) using the Autonomous Laser (Alcon Summit Autonomous, Waltham, MA) and Hansatome microkeratome (Bausch & Lomb Surgical, Bracknell, England). MAIN OUTCOME MEASURES: Uncorrected visual acuity (UCVA), manifest spherical equivalent (MSE), best spectacle-corrected visual acuity (BSCVA), and complications were studied. RESULTS: At 12 months, the mean MSE was -0.02 +/- 1.01 D, with 79.1% of eyes within 0.5 D and 89.9% of eyes within 1 D of the intended correction. UCVA was 20/20 or better in 71.4%, 20/25 or better in 78.5%, and 20/40 or better in 92.8% of eyes. Two eyes (1.6%) lost 2 lines and five eyes (3.8%) gained 2 lines of BSCVA. Sixteen eyes (12.4%) required retreatment to correct residual myopia or astigmatism. After retreatment, 14 of 16 eyes were within 0.5 D of emmetropia. Nine eyes (6.9%) had minor flap complications; two eyes (1.6%) had grade 2 diffuse lamellar keratitis, of which one eye had associated peripheral flap melt. One eye showed slight decentration; this eye was rolling throughout the procedure. All eyes had some dryness, with 10% severe enough to require temporary punctual occlusion with plugs. CONCLUSIONS: T-LASIK for myopic astigmatism with the Autonomous Laser is relatively safe, effective, and predictable. The tracker seems to be effective, and the complications are relatively few. Retreatment rates are acceptable and can be performed safely and effectively to improve visual outcome. The outcomes are comparable with other published data.  相似文献   

13.
Laser-assisted subepithelial keratectomy for the correction of myopia   总被引:20,自引:0,他引:20  
PURPOSE: To evaluate the results of laser-assisted subepithelial keratectomy (LASEK) for spherical and spherocylindrical myopia. SETTING: Indiana Eye Institute, South Bend, Indiana, USA. METHODS: In a retrospective noncomparative single-surgeon interventional case series, outcomes in 222 consecutive eyes with myopia ranging from -1.25 to -11.25 diopters (D) and astigmatism up to +2.25 D treated with LASEK using a VISX Star S2 excimer laser were analyzed 4 days, 2 weeks, and 3, 6, and 12 months after surgery. RESULTS: The uncorrected visual acuity (UCVA) was 20/40 or better in 84% of eyes at 4 days and in 98% at 2 weeks. At 12 months, in 84 eyes, the UCVA was 20/15 in 16 eyes (19.0%), 20/20 in 53 (63.1%), and 20/25 in 15 (17.9%). There was no loss of best spectacle-corrected visual acuity (BSCVA), and no eye required retreatment. CONCLUSION: Laser-assisted subepithelial keratectomy for myopia provided excellent refractive and visual results with no loss of BSCVA and no serious complications. Subjective results and other measures of visual function need further evaluation.  相似文献   

14.
PURPOSE: To prospectively evaluate the safety, efficacy, and visual performance of excimer laser enhancement following photoastigmatic refractive keratectomy (PARK) with the Summit Apex Plus. SETTING: Stanford University School of Medicine Eye Laser Clinic, Stanford, California, USA. METHODS: As part of a Food and Drug Administration clinical trial, 93 eyes of 56 patients with a mean spherical equivalent (SE) of -4.98 diopters (D) +/- 1.80 (SD) (range -1.75 to -8.50 D) had PARK for compound myopic astigmatism using the Summit Apex Plus excimer laser and a poly(methyl methacrylate) erodible mask. Seventeen eyes with a mean SE of -2.08 +/- 0.76 D required excimer laser refractive keratectomy for residual spherical myopia or compound myopic astigmatism. Patients were prospectively followed 1, 3, 6, 9, and 12+ months after the enhancement procedure. Primary outcome variables included uncorrected visual acuity (UCVA), refraction, vector analysis, best spectacle-corrected visual acuity (BSCVA) under standard ambient conditions (photopic, scotopic, and glare), corneal clarity, and contrast sensitivity function curve under photopic and scotopic conditions. RESULTS: At the last postoperative visit, the mean sphere had been corrected 82% to a residual of -0.29 +/- 1.23 D and mean SE had been corrected 65% to a residual of -0.74 +/- 1.27 D. Eighty-two percent of eyes were within +/-1.0 D of attempted correction. Eighty-eight percent had a UCVA of 20/40 or better. Vector analysis demonstrated a difference vector of within +/-1.0 D in 75% of eyes that had PARK retreatment. There was no significant loss in the contrast sensitivity curve. Late regression associated with corneal haze and loss of BSCVA occurred in 2 eyes (11.7%). CONCLUSIONS: Retreatment following PARK for compound myopic astigmatism results in effective reduction in residual spherical myopia and compound myopic astigmatism. An improvement in UCVA without loss of contrast sensitivity can be expected in most eyes. However, regression, corneal haze, and loss of BSCVA may occur. Further studies are indicated to predict risk factors for these complications.  相似文献   

15.
PURPOSE: To evaluate the safety, efficacy, and predictability of excimer laser in situ keratomileusis (LASIK) to correct residual myopia and astigmatism after penetrating keratoplasty (PKP). SETTING: Buzard Eye Institute, Las Vegas, Nevada, USA. METHODS: Twenty-six eyes had LASIK at least 1 year after PKP. All eyes were followed for at least 6 months after LASIK; 22 eyes were followed for 12 months. Sutures were removed at a mean of 13 months post PKP. Laser in situ keratomileusis was performed with the Chiron Automated Corneal Shaper microkeratome (Bausch & Lomb) and the Visx Star excimer laser. Before LASIK, the mean spherical equivalent (SE) was -4.94 diopters (D) +/- 2.79 (SD) and the mean astigmatism was 2.71 +/- 2.33 D; all eyes had regular astigmatism or slightly decentered, irregular astigmatism. RESULTS: At the last follow-up, the mean postoperative uncorrected visual acuity (UCVA) was 20/30, the mean SE was -0.35 +/- 0.65 D, and the mean residual astigmatism was 1.06 +/- 0.67 D. Eighty-six percent of patients had an SE within +/-1.00 D of emmetropia and a UCVA of 20/40 or better. Ten eyes (39%) had 1 or more enhancements, which were performed a mean of 6 months after the primary LASIK. Significant complications such as wound dehiscence, epithelial ingrowth, and corneal decompensation did not occur. At the last follow-up, 18% of patients lost 1 line of best corrected visual acuity and 27% gained 1 line. CONCLUSION: Laser in situ keratomileusis appeared to be a reliable and safe procedure to correct residual myopia and astigmatism after PKP.  相似文献   

16.
PURPOSE: To evaluate the Artisan toric phakic intraocular lens (pIOL) for the correction of hyperopia and astigmatism. SETTING: Department of Ophthalmology, Erasmus MC, Rotterdam, The Netherlands, and Department of Ophthalmology, Sint Truiden, Belgium. METHODS: In this prospective study of 47 eyes of 28 patients with hyperopia and astigmatism, Artisan toric pIOLs were implanted between April 1999 and June 2004. Uncorrected visual acuity (UCVA), best corrected visual acuity, refraction, astigmatism, safety, and predictability were analyzed. Change in astigmatism was analyzed with vector analysis. Refractive cylinders are expressed in minus form. RESULTS: Mean preoperative spherical equivalent was +4.33 diopters (D) +/- 2.26 (SD). Mean follow-up was 11.1 months (range 6 to 36 months). A gain of 1 or more lines in best spectacle-corrected visual acuity (BSCVA) was seen in 36.2%. Safety index and efficacy index after 6 months were 1.06 and 0.87, respectively. The mean postoperative astigmatism at 6 months was 0.19 D at an axis of 144 degrees. At 6 months, about three quarters (76.6%) of the eyes had a UCVA of 20/40 or better. One eye lost 2 lines of BSCVA. In 1 eye, the lens position had to be changed because of a large axis misalignment. No serious complications developed in any of the treated eyes during follow-up. CONCLUSIONS: Artisan toric pIOLs can correct moderate to high hyperopia combined with astigmatism with good refractive results. In this study, there were no serious complications. However, the predictability of the refractive results appeared to be lower than those in the correction of myopia and astigmatism with toric Artisan lenses.  相似文献   

17.
PURPOSE: To evaluate the efficacy, predictability, and safety of wavefront-guided laser in situ keratomileusis (LASIK) using the Visx CustomVue excimer laser (Advanced Medical Optics) in eyes with consecutive hyperopia and compound hyperopic astigmatism after LASIK. SETTING: Stanford University School of Medicine, Department of Ophthalmology, Stanford, California, USA. METHODS: This retrospective analysis included 19 eyes of 16 patients who had wavefront-guided LASIK for consecutive hyperopia and compound hyperopic astigmatism after initial LASIK surgery. Primary outcome variables, including uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), higher-order aberration (HOA) analysis, and spherical equivalence, were evaluated at 1 and 3 months. Nine eyes of 7 patients were available for all visits. RESULTS: The mean patient age was 51.7 years +/- 3.77 (SD) (range 44 to 55 years). The mean preoperative manifest refractive spherical equivalent (MRSE) was 0.99 +/- 0.32 diopters (D) (range 0.50 to 1.50 D) and the mean 3-month postoperative MRSE, -0.04 +/- 0.66 D (range -1.50 to 0.75 D). At 1 month, 57.9% of eyes had a UCVA of 20/20 or better and 78.9% of 20/25 or better; 84.2% were within +/-1.00 D of emmetropia. At 3 months, 66.7% of eyes had a UCVA of 20/20 or better and 88.9% of 20/25 or better; 88.9% were within +/-1.00 D of emmetropia. No eye lost 2 or more lines of BSCVA at 1 or 3 months. CONCLUSION: Wavefront-guided LASIK was an effective, predictable, and safe procedure for consecutive hyperopia and compound hyperopic astigmatism after LASIK.  相似文献   

18.
PURPOSE: To compare the efficacy, predictability, and safety of Zernike-based versus Fourier-based treatment tables in myopic eyes 1 year after CustomVue wavefront laser in situ keratomileusis (LASIK) using the S4 excimer laser (Visx). SETTING: Department of Ophthalmology, Stanford University School of Medicine, Stanford, California, USA. METHODS: A prospective analysis of 32 eyes of 16 patients with myopia who had CustomVue LASIK with the S4 excimer laser was conducted using Zernike or Fourier treatment tables. Mean spherical equivalent (SE), uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), and higher wavefront analyses were determined. RESULTS: The mean postoperative SE was -0.27 diopter (D) +/- 0.41 (SD) in Zernike-treated eyes and -0.20 +/- 0.29 D in Fourier-treated eyes. Twenty-eight of 32 eyes were available for analysis. Ninety-two percent of eyes in the Zernike group and all eyes in the Fourier group had 20/20 or better acuity (P = .85). Seventy-nine percent and 92%, respectively, were within +/-0.50 D of emmetropia (P = .68). All eyes in the Zernike group and 93% of eyes in the Fourier group had no change or gained at least 1 Snellen line of BSCVA (P = .85). Mean higher-order aberration values (mum) in the Zernike group and Fourier group were as follows: total root mean square, 0.91 and 0.99, (P = 0.95); defocus, 0.71 and 0.74, (P = 0.98); astigmatism, 0.15 and 0.31, (P = 0.81); coma, 0.21 and 0.20, (P = 0.99); trefoil, 0.11 and 0.11, (P = 1); and spherical aberration, 0.17 and 0.30, (P = 0.85), respectively. CONCLUSIONS: Myopic eyes that had CustomVue LASIK had better visual outcomes in the Fourier group than in the Zernike group. Higher-order wavefront aberration results were similar between the 2 groups.  相似文献   

19.
PURPOSE: To evaluate the effectiveness, predictability, and safety of laser in situ keratomileusis (LASIK) for correcting myopia greater than -10.00 D. METHODS: Sixty-five eyes of 37 patients with myopia greater than -10.00 D underwent LASIK. Patients were evaluated on day 1, 1 week, 1, 3, and 6 months after surgery. Parameters evaluated were uncorrected visual acuity (UCVA) and best spectacle-corrected visual acuity (BSCVA), residual refractive error, regression of correction, and presence of any complication. RESULTS: Mean preoperative BSCVA was 0.745 +/- 0.234, which improved to 0.8070 +/- 0.237 postoperatively. The average preoperative UCVA was 0.022 +/- 0.02; postoperative UCVA at 6 months was 0.536 +/- 0.255. UCVA of 20/40 or better was achieved in 58% (38 eyes) and 20/20 or better in 26% (17 eyes). The average refractive error before LASIK was -12.64 +/- 2.16 D (range -10.00 to -19.00 D). Mean residual refractive error 1 week following LASIK was -0.63 +/- 1.36 D, which regressed to a mean -1.78 +/- 2.08 D at the end of 6 months. Nineteen eyes (29%) were within +/-0.50 D of intended refractive correction. CONCLUSION: LASIK was partially effective in the correction of high myopia. An initial overcorrection may be programmed to offset the effect of refractive regression.  相似文献   

20.
PURPOSE: To evaluate the efficacy, predictability, and safety of laser subepithelial keratomileusis (LASEK) for treatment of high myopia with astigmatism. METHODS: LASEK was performed in 61 eyes of 36 consecutive patients with myopic spherical equivalent refraction of -6.00 to -10.00 D using the Aesculap-Meditec MEL60 excimer laser. Data were collected prospectively with a follow-up of 6 to 17 months. Main outcome measures recorded were UCVA, BSCVA, residual refractive error, corneal haze, and complications. RESULTS: Ninety-six percent of eyes achieved 20/40 or better UCVA at 1 month. At 12 months, 64% of eyes achieved 20/20 and 92% achieved 20/40 or better UCVA. Two eyes lost 2 lines of BSCVA at 6 or 12 months. Accuracy of correction was +/- 0.50 D from emmetropia in 82% of eyes, and +/- 1.00 D in 90% at 12 months. No eye showed more than grade 1 haze. Grade 1 haze was observed in three eyes at 12 months. One patient had mild postoperative keratitis, which was successfully treated. CONCLUSIONS: LASEK with the Aesculap-Meditec MEL60 excimer laser appeared to be safe, effective, and highly predictable in treating high myopia.  相似文献   