1.
目的:研究TrueBeam加速器的射野跟随功能在鼻咽癌固定野调强放疗和容积旋转调强放疗中的作用;方法:随机选取10例鼻咽癌患者.分别对每位患者设计四个计划.分别为固定野调强组的dIMRT-JT和dlMRT计划,容积旋转调强组的RapidArc—JT和RapidArc计划。dIMRT-JT和RapidAre-JT为使用射野跟随功能的计划,dIMRT和RapidArc为不使用射野跟随功能的计划。分别比较使用和不使用射野跟随功能的治疗计划.患者靶区和危及器官的剂量学差异;结果:固定野调强计划,在使用和不使用射野准直器跟随功能,其靶区的剂量学参数差别不大,但是脑干、脊髓、晶状体、腮腺等危及器官都有较大改善,脑干和脊髓的D,。剂量分别降低了3.3%和4.2%,左、右两侧晶状体的D。剂量分别降低了38.7%和40.6%,左、右两侧腮腺的平均剂量D一分别降低了6.3%和6.4%;P〈0.05,有统计学意义。容积旋转调强计划,在使用和不适用射野准直器跟随功能时,靶区和脑干、脊髓及腮腺等危及器官的剂量学差异很小,没有统计学意义;而左、右两侧晶状体的D。剂量分别降低了6.9%和7.2%;结论:鼻咽癌固定野调强放疗和容积旋转调强放疗中,使用TrueBeam加速器的射野准直器跟随功能,可以在保证靶区剂量分布不变的前提下,降低危及器官的受照剂量。尤其在固定野调强放疗中,使用射野准直器跟随功能的计划其剂量学优势非常明显。  相似文献   

2.
【摘要】目的:研究多叶准直器(MLC)叶片系统误差对鼻咽癌容积调强(VMAT)计划和普通调强(IMRT)计划剂量学影响的差异。方法:随机选取20例鼻咽癌患者,分别设计VMAT计划和IMRT计划。通过MATLAB 2009a只修改计划文件中MLC运动叶片的位置,人为引入0.2、0.5、1.0 mm的系统误差,导入治疗计划系统中重新进行剂量计算。对两种调强技术,比较靶区和危及器官生物学剂量(gEUD)受叶片位置误差影响的差异,并研究gEUD差值与叶片误差之间的关系。结果:靶区和危及器官两种计划gEUD的变化差异具有统计学意义(P<0.01)。PGTV、PTVnd、PTV1、PTV2、脑干、脊髓、左侧腮腺、右侧腮腺等gEUD的变化与叶片误差成线性关系,VMAT计划分别变化为3.6、3.8、4.0、3.0、5.6、5.6、6.8、6.8 %/mm(P<0.001);IMRT计划分别变化为10.7、10.5、11.2、10.7、16.6、15.0、14.6、14.4 %/mm(P<0.001)。结论:MLC叶片系统误差对VMAT计划剂量的影响比IMRT计划小。为保证PGTV的gEUD变化控制在2%以内,VMAT和IMRT叶片系统误差应分别小于0.6和0.2 mm。  相似文献   

3.
目的:通过分析50例鼻咽癌调强放疗的TPS资料中Ib区、颌下腺的剂量分布特点,为个体化制定鼻咽癌调强放疗计划提供依据。方法:50例于2011年1月至2011年6月接受调强放射治疗(IMRT)的初治鼻咽癌患者被纳入研究。收集所有患者IMRT计划的TPS数据,分析其Ib区、颌下腺计划外受照射体积剂量特点。结果:50例TPS数据中双侧Ib区平均体积为9.03 mm^3±2.22 mm^3,平均剂量达52.42 Gy±4.30 Gy,V30、V35、V40、V45、V50、V55、V60的百分比分别为99.4%、83.1%,94%、83.1%、64.3%、58.1%、35.5%、21.6%。双侧颌下腺平均体积为7.03 mm^3±1.05 mm^3,平均剂量为58.51 Gy±5.35 Gy,接受30 Gy、40 Gy、50 Gy、60 Gy的体积分别为100%、99.1%、89.7%、71.2%。结论:在鼻咽癌调强放射治疗中,即使Ib区不予预防照射,Ib区和颌下腺均已接受较高的计划外照射。颌下腺的计划外剂量已经超出其功能保全剂量。  相似文献   

4.
目的:研究两种规格(等中心处投影0.5和1.0 cm)多叶准直器(MLC)在鼻咽癌调强放射治疗(IMRT)计划中的区别,从剂量学方面探究MLC的宽度对患者靶区和危及器官的影响。方法:随机选取已完成治疗的31例鼻咽癌患者计划,在放疗处方和物理优化参数不变的情况下分别使用两种规格MLC的加速器射野模型进行重新优化计算,统计靶区及主要危及器官的体积剂量、平均剂量(Dmean)、适形度指数(CI)、均匀性指数(HI)等参数,分析其差异性。结果:全样本分析显示,所有靶区HI和部分靶区(PGTVnx、PCTV2)CI差异有统计学意义(P<0.05),0.5 cm MLC优于1.0 cm MLC;危及器官中,右侧视神经和视交叉最大剂量(Dmax)、左侧颞叶和右侧颞颌关节Dmean、左右腮腺V30、气管和脊髓Dmean差异有统计学意义(P<0.05),0.5 cm MLC优于1.0 cm MLC,其他危及器官无统计学差异(P>0.05);在Pinnacle3和Monaco计划系统中得到了相似结果,两种MLC在靶区适形度和均匀性方面及部分危及器官受量差异有统计学意义(P<0.05)。结论:0.5 cm MLC在鼻咽癌调强计划中能有效提高靶区适形度和均匀性,也能有效降低部分危及器官受量,可以更好地保护与靶区邻近或有重叠的一些危及器官,推荐有条件的医院使用。  相似文献   

5.
通过对束流匹配的加速器进行计划设计,比较计划参数,验证交叉执行的差异及通过率,验证束流匹配的可行性及可靠性。选取头颈、胸部和腹盆部共15例病例,分别设计Clinac iX和Trilogy两个不同治疗机的三维适形计划(3D-CRT);另选头颈、胸部和腹盆部共15例病例,分别设计两个不同治疗机的调强计划(IMRT)。比较相同计划类型不同治疗机的计划差异,评价指标包括靶区PTV的D98%、D2%、Dmax,晶体Dmax、脑干Dmax、左右肺V5 Gy、双肺V20 Gy、脊髓Dmax、膀胱D50%、小肠D2 cc、股骨头V40 Gy等危及器官及治疗机跳数MU。并对治疗机执行计划进行点剂量和面剂量验证。PTV的D98%、D2%、Dmax剂量差异最大平均值标准差分别为-0.52%±0.30%、0.53%±0.45%、-0.55%±0.17%,危及器官剂量差异最大平均值为膀胱D50%(0.94%±0.84%);Clinac iX和Trilogy治疗机执行所有计划的最大绝对剂量偏差分别为2.36%和-2.80%。MatriXX和PV的γ验证通过率结果平均值分别在97.00%和96.00%以上,Clinac iX最小值为95.40%,Trilogy最小值为95.90%。两台经过束流匹配的治疗机之间交换执行计划的剂量学偏差在临床可接受的范围内,各项参数能精准执行,必要时可以在两台治疗机之间交换执行计划,保证病人放疗疗程完整。  相似文献   

6.
目的:讨论鼻咽癌调强放疗计划设计和优化方法.方法:随机选取24例鼻咽癌患者.在Eclips计划系统上对其进行调强放疗计划设计.对靶区和危及器官设定剂量体积限制条件和权重因子.并对凹形靶区对应的扇形正常组织、正常组织中的剂量热点和靶区中的剂量冷点定义剂量成形结构,对这三种剂量成形结构进行优化.最终得到一个现有条件下的最优化计划.结果:分析患者的剂量体积直方图,24例患者GTV1的最大剂量、最小剂量和平均剂量的平均值分别为73.46 Gy,、67.86 Gy和70.65 Gy,GTV2的最大剂量、最小剂量和平均剂量的平均值分别为68.83 Gy、64.67 Gy和66.29 Gy,CTV1的最小剂量为60.95 Gy,CTV2的最小剂量为51.37 Gy.1%体积的脊髓、脑干和视神经所接受的平均剂量为38.10 Gy、46.94 Gy和27.43 Gy,50%体积左侧和右侧腮腺所接受的剂量分别为36.03 Gy和35.88 Gy.结论:通过射野数目、方向的选择,剂量体积约束条件和权重因子合理的设定,以及对DSS的合理定义及优化,最终可以得到一个符合临床要求的较佳的调强治疗计划.靶区在各个断面都能得到较好的剂量覆盖,调强治疗能够提高靶区剂量的同时保护靶区周围的正常组织和重要器官.  相似文献   

7.
目的:研究多叶准直器(MLC)叶片运行速度对采用滑窗技术实施动态调强放射治疗时剂量分布的影响。方法:手工设计一组滑窗调强(SW-IMRT)照射野叶片序列(子野)文件P-MLC,在不同的剂量率、不同的机器跳数(MU)条件下运行,使得叶片的运行速度分别为1.0 cm/s、2.0 cm/s、3.0 cm/s、4.0 cm/s、5.0 cm/s、6.0 cm/s、7.0 cm/s、8.0 cm/s、10.0 cm/s、15.0 cm/s,用Mapcheck测量不同速度运行时的剂量分布,分别与PMLC在计划系统里计算的剂量分布相比较;选择10例鼻咽癌调强计划,在加速器上分别以100 MU/m、200 MU/m、300 MU/m、400 MU/m、500 MU/m、600 MU/m剂量率运行,用Mapcheck测量其剂量分布并与计划系统剂量分布比较其通过率;同时记录10例病人不同剂量率条件下运行时的加速器日志文件,将日志文件转换成实际运行MLC文件D-MLC后,将D-MLC导入计划系统重新计算,模拟比较不同剂量率条件下病人体内的剂量分布的差别。结果:在MLC计划速度设置为15.00 cm/s时,加速器实际叶片速度达到了(2.78±1.45)cm/s,最大速度为4.55 cm/s;加速器在MLC设定速度不超过5.00 cm/s运行计划文件时,通过降低剂量率的方式可以匹配叶片运动速度的限制,保证了实际照射时加速器输出的射野通量与计划设计时的最佳射野通量相一致,Mapcheck验证通过率在99%以上,但在设定速度超过5.00 cm/s运行计划文件时,通过降低剂量率的方式已无法匹配叶片运动速度的限制,Mapcheck验证通过率在随着设定速度的上升而降低;对实际临床病例的研究并未出现上述结果,不同的剂量率运行时其剂量分布及Mapcheck验证通过率没有明显差异(P=0.999)。结论:MLC叶片的运动速度可能会对滑窗调强放疗技术的剂量分布产生一定的影响,尽管在临床实际治疗中,这种影响很微弱,但这种方法可以作为直线加速器和治疗计划系统的验收或实施SW-IMRT技术日常QA工作的一种手段。  相似文献   

8.
目的:利用螺旋断层放射治疗技术与传统医用直线加速器对乳腺癌放疗中重要正常组织与靶区剂量-体积参数进行剂量学比较。同时,在剂量学研究基础上进行临床实际吸收剂量测量验证各种技术间临床应用的优势与劣势。 方法:选取10例T1N0M0期乳腺癌保乳术后行乳腺靶区放射治疗病人(无锁骨上照射区域),处方剂量为50 Gy/25次,利用螺旋断层放射治疗定角调强技术、螺旋断层放疗技术与医用直线加速器调强技术,比较乳腺癌靶区剂量和正常组织剂量的优劣。评估靶区剂量与适形度指数(CI)、均匀性指数(HI)和正常组织剂量-体积参数,进行剂量学比较。同时,利用热释光剂量仪在乳腺癌病人表皮进行实测剂量,比较3种技术处理由于病人呼吸运动对表面剂量的影响,及评估时间因素对治疗效率的影响。 结果:10例乳腺癌病人采用定角调强技术、螺旋断层放疗技术与医用直线加速器调强技术PTV HI分别为0.15±0.01、0.06±0.01和0.20±0.15(P<0.001);CI分别为0.76±0.00、0.81±0.03和0.74±0.04(P>0.05);心脏平均剂量分别为4.12±0.87、3.82±0.53、6.33±2.49 Gy(P<0.001),左前降支最大剂量分别为20.38±5.66、13.34±3.78、34.56±4.12 Gy(P<0.001),患侧肺组织平均剂量分别为6.78±1.33、7.22±2.34、12.76±2.10 Gy(P<0.001)。患者6个实测剂量点的吸收剂量3种技术比较有统计学意义(P<0.001)。 结论:从综合靶区覆盖、正常组织剂量-体积参数、剂量实测与治疗效率等方面比较,螺旋断层放射治疗的定角调强技术相对于其他两种技术而言有低剂量范围小、靶区覆盖佳、解决治疗中呼吸运动影响等优势,推荐使用该技术用于乳腺癌病人放射治疗。  相似文献   

9.
鼻咽癌调强放疗中摆位误差对物理剂量学的影响   总被引:1,自引:0,他引:1  
目的:测量头颈部肿瘤在放射治疗中的摆位误差,分析鼻咽癌(NPC)调强放射治疗(IMRT)中误差对靶区和危及器官物理剂量学的影响。方法:随机抽取76名头颈部肿瘤患者,通过比较数字重建图像(DRR)和射野图像,测量其摆位误差;从其他住院患者中随机抽取另外10名作调强治疗的鼻咽癌患者,在计划系统中模拟患者治疗时体位的三维误差,重新计算剂量分布,分析一系列相关的靶区和危及器官的剂量参数,明确摆位误差对物理剂量的影响。结果:头颈部肿瘤在左右、头脚、腹背方向的摆位误差分别是(-0.62±1.46)mm,(-0.41±1.54)mm,(-0.31±1.67)mm;鼻咽癌调强放疗中超过3mm的摆位误差对GTV的最小剂量和CTV个别剂量参数的影响有统计学意义,腹背方向的误差对脊髓和脑干受照剂量的影响有统计学意义。结论:对于鼻咽癌调强治疗的患者,摆位误差需要控制在3mm之内:在日常工作中用EPID做质量保证和质量控制工作很有必要。  相似文献   

10.
目的:比较瓦里安Eclipse治疗计划系统中AAA算法和PBC算法在鼻咽癌调强放疗中靶区的剂量分布和危及器官受照剂量的差别。方法:选择我科治疗的鼻咽癌患者10例,分别采用Eclipse(7.6版本)治疗计划系统中AAA算法和PBC算法进行调强优化,优化条件相同,计算剂量分布。分析并比较10例患者的靶区、危及器官的受照剂量。结果:发现PBC算法和AAA算法对靶区剂量(PTV)影响不大,对脑干、晶体、视神经、脊髓四种危及器官的影响中,晶体的剂量差别较大,其次为视神经。结论:分析晶体受照剂量差别大的主要原因是晶体的受照剂量主要来自光栅运动中散射,AAA算法对散射的修正比PBC算法更为精确,所以在鼻咽癌调强治疗计划中AAA算法更为精确。  相似文献   

11.
【摘 要】 目的:应用两种胶片分析方法分析调强治疗多叶光栅(MLC)到位精确度。 方法:选择4个省共15家医院,其中8家为Varian加速器,MLC型号均为Millenium 120;7家为Elekta加速器,MLC型号为MLCi或MLCi2。胶片放在固体水模体30 cm×30 cm,dmax点处(水下1.5 cm),SAD=100 cm,6 MV照射,250 MU(监督系数)/栅栏野,应用计划系统,在EBT3胶片上形成5条MLC栅栏野,每条栅栏野射野宽度为6 mm,5条栅栏野射野中心位置相对于中间栅栏野射野中心的位置距离分别为-6、-3、0、3、6 cm。将照射后的胶片用Epson Expression 10000XL扫描,应用Film QATM Pro软件得到栅栏野剂量曲线(profile),并用两种归一方法即截断部分光密度值区域后归一和归一到局部位置区的光密度值,从射野位置及中心位置偏差、射野宽度及偏差4个方面分析比较MLC到位精确及多中心测量结果。 结果:两种分析方法比较,5条栅栏野实际射野位置相对于计划射野位置偏差,均测得9家医院位置偏差超过国际原子能机构(IAEA)规定偏差限值±0.5 mm;分析每条栅栏野射野中心位置的偏差,分析结果均符合IAEA规定限值±0.5 mm;分析5条栅栏野宽度,并与计划设定宽度6 mm相比较,偏差均符合IAEA规定不超过±1 mm;分析射野宽度最大最小值偏差及标准差,分析结果均符合IAEA规定偏差不超过±0.75 mm,标准差不超过0.30 mm。 结论:两种胶片分析方法测量MLC叶片到位精确度,结果相近,差别较小,在此实验中两种归一方法均可被用。  相似文献   

12.
To evaluate in an objective way the effect of leaf interdigitation and leaf width on volumetric modulated arc therapy plans in Pinnacle. Three multileaf collimators (MLCs) were modeled: two 10?mm leaf width MLCs, with and without interdigitating leafs, and a 5?mm leaf width MLC with interdigitating leafs. Three rectum patients and three prostate patients were used for the planning study. In order to compare treatment techniques in an objective way, a Pareto front comparison was carried out. 200 plans were generated in an automated way, per patient per MLC model, resulting in a total of 3600 plans. From these plans, Pareto-optimal plans were selected which were evaluated for various dosimetric variables. The capability of leaf interdigitation showed little dosimetric impact on the treatment plans, when comparing the 10?mm leaf width MLC with and without leaf interdigitation. When comparing the 10?mm leaf width MLC with the 5?mm leaf width MLC, both with interdigitating leafs, improvement in plan quality was observed. For both patient groups, the integral dose was reduced by 0.6 J for the thin MLC. For the prostate patients, the mean dose to the anal sphincter was reduced by 1.8 Gy and the conformity of the V(95%)?was reduced by 0.02 using the thin MLC. The V(65%)?of the rectum was reduced by 0.1% and the dose homogeneity with 1.5%. For rectum patients, the mean dose to the bowel was reduced by 1.4 Gy and the mean dose to the bladder with 0.8 Gy for the thin MLC. The conformity of the V(95%)?was equivalent for the 10 and 5?mm leaf width MLCs for the rectum patients. We have objectively compared three types of MLCs in a planning study for prostate and rectum patients by analyzing Pareto-optimal plans which were generated in an automated way. Interdigitation of MLC leafs does not generate better plans using the SmartArc algorithm in Pinnacle. Changing the MLC leaf width from 10 to 5?mm generates better treatment plans although the clinical relevance remains to be proven.  相似文献   

13.
14.
倪千喜  张琳 《中国医学物理学杂志》2010,27(6):2218-2223,2243
目的:利用放射治疗计划系统(TPS)对鼻咽癌面颈联合野与颈前切线野进行射野衔接,观察射野衔接处的剂量分布。方法:选择一例鼻咽癌患者,通过CT模拟定位,利用TPS进行鼻咽癌面颈联合野与颈前切线野间的射野衔接。使得射野衔接处剂量均匀,同时模拟计算鼻咽癌常规定位时相邻射野重叠或留空1 mm,2 mm,3 mm,4 mm,5 mm时衔接处的剂量。均给予第一阶段处方剂量36 Gy/18次,分析射野衔接处感兴趣区域(ROI)的剂量分布情况。结果:相邻射野重叠1 mm~5 mm,ROI接受120%处方剂量的体积≥10%,135%处方剂量的体积≥5%,Dmax为处方剂量的143%~148%。脊髓的最大剂量几乎没有影响,其变化幅度≤0.5%。脊髓的V36增加约3%;相邻射野留空1 mm~5 mm,ROI的D95从36Gy降到24.1 Gy,降幅为33%。结论:利用TPS进行鼻咽癌面颈联合野与颈前切线野的衔接,可以保证射野衔接处的剂量均匀性,避免出现严重的剂量冷点及热点,确保靶区内剂量,较好地保护部分正常组织。  相似文献   

15.
The characteristics of a commercial multileaf collimator (MLC) to deliver static and dynamic multileaf collimation (SMLC and DMLC, respectively) were investigated to determine their influence on intensity modulated radiation therapy (IMRT) treatment planning and quality assurance. The influence of MLC leaf positioning accuracy on sequentially abutted SMLC fields was measured by creating abutting fields with selected gaps and overlaps. These data were also used to measure static leaf positioning precision. The characteristics of high leaf-velocity DMLC delivery were measured with constant velocity leaf sequences starting with an open field and closing a single leaf bank. A range of 1-72 monitor units (MU) was used providing a range of leaf velocities. The field abutment measurements yielded dose errors (as a percentage of the open field max dose) of 16.7+/-0.7% mm(-1) and 12.8+/-0.7% mm(-1) for 6 MV and 18 MV photon beams, respectively. The MLC leaf positioning precision was 0.080+/-0.018 mm (single standard deviation) highlighting the excellent delivery hardware tolerances for the tested beam delivery geometry. The high leaf-velocity DMLC measurements showed delivery artifacts when the leaf sequence and selected monitor units caused the linear accelerator to move the leaves at their maximum velocity while modulating the accelerator dose rate to deliver the desired leaf and MU sequence (termed leaf-velocity limited delivery). According to the vendor, a unique feature to their linear accelerator and MLC is that the dose rate is reduced to provide the correct cm MU(-1) leaf velocity when the delivery is leaf-velocity limited. However, it was found that the system delivered roughly 1 MU per pulse when the delivery was leaf-velocity limited causing dose profiles to exhibit discrete steps rather than a smooth dose gradient. The root mean square difference between the steps and desired linear gradient was less than 3% when more than 4 MU were used. The average dose per MU was greater and less than desired for closing and opening leaf patterns, respectively, when the delivery was leaf-velocity limited. The results indicated that the dose delivery artifacts should be minor for most clinical cases, but limit the assumption of dose linearity when significantly reducing the delivered dose for dosimeter characterization studies or QA measurements.  相似文献   

16.
The multi-leaf collimator (MLC) of a particular linear accelerator vendor (Millennium MLC, Varian Medical Systems, Palo Alto, CA, USA) has a maximum leaf extension of 14.5 cm. To achieve intensity modulated radiotherapy (IMRT) for fields wider than 14.5 cm all closed leaf pairs are restricted to placement inside the field. Due to the rounded leaf end design of the MLC end leaf leakage will occur in the treatment field. The implementation of direct aperture optimization in the IMRT module of a radiotherapy treatment planning system (Pinnacle, Philips Radiation Oncology Systems, Milpitas, CA) has facilitated the delivery of IMRT fields wider than 14.5 cm. The end leaf leakage of the Millennium MLC has been characterized for 6 MV photons using gafchromic and radiographic film, and the accuracy of the planning system verified. The maximum leakage measured for a single field was 0.39 cGy MU(-1) for a 0 mm leaf gap and 0.51 cGy MU(-1) for a 0.6 mm leaf gap. For a clinical IMRT field leaf end leakage contributed an additional 2-3 Gy over the course of treatment. The planning system underestimated the magnitude of end leaf leakage by 20-40%. The ability to deliver IMRT fields wider than 14.5 cm with the Millennium MLC has improved the efficiency and flexibility of IMRT treatments; however, significant extra dose can be introduced due to end leaf leakage. Caution should be exercised when delivering wide field IMRT as it is not a complete panacea. Any significant occurrences of end leaf leakage predicted by the planning system should be independently verified prior to delivery.  相似文献   

17.
In this study, we quantify the impact of linac/MLC design parameters on IMRT treatment plans. The investigated parameters were leaf width in the MLC, leaf transmission, related to the thickness of the leaves, and penumbra related primarily to the source size. Seven head-and-neck patients with stage T1-T3N0-N2cM0 oropharyngeal cancer were studied. For each patient nine plans were made with a different set of linac/MLC parameters. The plans were optimized in Pinnacle(3) v7.6c and PLATO RTS v2.6.4, ITP v1.1.8. A hypothetical ideal linac/MLC was introduced to investigate the influence of one parameter at a time without interaction of other parameters. When any of the three parameters was increased from the ideal set-up values (leaf width 2.5 mm, transmission 0%, penumbra 3 mm), the mean dose to the parotid glands increased, given the same tumour coverage. The largest increase was found for increasing leaf transmission. The investigation showed that by changing more than one parameter of the ideal linac/MLC set-up, the increase in the mean dose was smaller than the sum of dose increments for each parameter separately. As a reference to clinical practice, we also optimized the plans of the seven patients with the clinically used Elekta SLi 15, equipped with a standard MLC with a leaf width of 10 mm. As compared to the ideal linac, this resulted in an increase of the average dose to the parotid glands of 5.8 Gy.  相似文献   

18.
目的:利用单方向x射线成像定位算法来实时定位肿瘤靶区可以提高放射治疗精度,应用简便的同时能够降低对病人曝光的成像剂量。但是由于缺少沿射线束方向上的运动信息,如何有效地利用之前的运动信息来保证定位精度是需要解决的一个问题。方法:针对前列腺肿瘤,选择4种典型的实时定位算法,并使用十位患者的Calypso磁场定位数据进行模拟定位来比较它们的定位效果。这四种定位算法分别是仅分布图法、两种基于高斯概率密度分布的算法和贝叶斯概率密度分布法。‘结果:仅分布图法的rmse(均方根误差)小于5mm,但是最大误差能达到50mm;高斯概率分布法1的rmse小于2.6mm,最大误差小于6mm;高斯概率分布法2的定位结果中多数病人的rmse小于1.5mm,最大误差小于7mm,而有部分病人的rmse大于4.5mm.最大误差大于30mm;贝叶斯概率密度分布法的rmse小于2.5mm,最大误差小于8.8mnl。结论:高斯概率密度分布法1和贝叶斯概率密度分布法相对优于其它两种;尤其是贝叶斯概率密度分布法能够最好地适用于各种类型的前列腺肿瘤运动的实时定位。  相似文献   