首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Quantitation assays of HIV-1 RNA used currently were designed and optimized for subtype B viruses. However, infection with non-B HIV viruses has become more common worldwide. Unfortunately, little information is available regarding the suitability of these assays for measurement of viral load in specific non-B subtypes. The performance of two commercial HIV-1 RNA quantitation assays was evaluated in 82 HIV subtype C-infected patients and in 43 HIV-1 subtype B-infected patients. Blood samples were tested by the Amplicor HIV-1 Monitor Assay, Version 1.5, and by the nucleic acid sequence-based amplification HIV-1 assay (NucliSens). The results were compared by using a paired, two-tailed Student's t-test; the difference between the assays was found to be significant only for subtype C. Discordant results (>0.5 log difference) between the two assays were detected in 39% of subtype C samples, compared to 23.2% of subtype B samples. In all cases in which a discordant result was detected, the lower results were obtained by the NucliSens assay. Discordant results between CD4 and viral load (CD4 < 200 cells/ml with a viral load <5,000 copies/ml) were observed in eight of the subtype C-infected patients when a viral load was measured by NucliSens (9.7%), compared to three patients (3.6%) when measured by the Amplicor assay. In conclusion, in patients with HIV subtype C infection, measurement of HIV RNA by the NucliSens assay resulted in a significant underestimation of the viral load as compared to the Amplicor assay. As a consequence, such an underestimation may result in sub-optimal care of patients infected with HIV subtype C.  相似文献   

2.
To assess the reproducibility of measurements of cervical and vaginal human immunodeficiency virus (HIV) viral load, 92 duplicate cervical and 88 duplicate vaginal samples were collected from 13 HIV-infected women using Sno Strip filter-paper wicks. RNA was eluted from the strips, extracted, and assayed using a modified protocol for the Roche Cobas Amplicor HIV-1 Monitor assay. Pearson's correlation coefficient (R), coefficient of determination (D), and Bland-Altman plots (BA) were used to compare paired log10-transformed viral loads. Analysis of duplicate same-site samples showed good reproducibility (cervix: R = 0.72, D = 52%, BA = 89% within range; vagina: R = 0.72, D = 51%, BA = 87% within range); paired cervix/vagina measurements showed moderate correlation only (R = 0.56; D = 31.3%). Standardized sample collection and simple modification of the Roche Cobas Amplicor HIV-1 Monitor assay allows reproducible measurement of genital viral load.  相似文献   

3.
4.
5.
The South African National Antiretroviral Treatment Guideline recommends the use of HIV viral load assays for routine monitoring of HIV-1 positive patients on Highly Active Antiretroviral Therapy (HAART). Approved commercial HIV-1 viral load assays are expensive for developing countries where a large number of patients are treated in the public sector. The evaluation of an in-house HIV-1 viral load assay (LUX assay) is described using 458 plasma specimens. Good specificity of the LUX assay was demonstrated using 50 seronegative plasma specimens. A group of 142 HIV-1 positive patients was used to assess the agreement between the LUX assay and the COBAS Amplicor assay. An intra class correlation (ICC) coefficient of 0.85 (CI 95%) indicated good agreement between the assays. The Bland-Altman model showed good agreement between the assays for approximately 87% of the results (mean 0.03 [-1.26; 1.32], CI 95%). In a cohort of 55 patients followed-up longitudinally the LUX assay showed similar declines in viral load to the COBAS Amplicor assay in response to therapy. Viral rebound was detected in 5 patients out of 55 by both assays. Thus, the LUX assay compares well to the gold standard and represents an affordable alternative for high volume testing in resource limited settings.  相似文献   

6.
In facing global programs for treating HIV-infected patients in the developing countries, there is a real need for viral load assays that are accurate for the local subtypes. The present study was designed to evaluate viral load measurements using the newer version of the NASBA assay in subtype C-infected patients. The performances of this new version, a real-time nucleic acid sequence-based amplification HIV-1 assay (NucliSens EasyQ), were compared to Amplicor HIV-1 Monitor Assay version 1.5 in 79 samples of subtype C-infected patients originating from Ethiopia. Twenty HIV-1 subtype B-infected patients served as a control group. Blood samples from patients in both groups were tested by both assays. The results were compared by a paired, two-tailed Student's t-test. The disparity between the results of the two viral load assays was highly significant in subtype C samples (P = 0.005), such that in the vast majority, higher values of viral load were obtained by the Amplicor assay. However, no differences between the two assays were found in subtype B samples (P = 0.77). CD4 measurements were available for 78 samples of subtype C-infected patients. Of these, a CD4-to-viral load discrepancy (CD4 相似文献   

7.
We compared the performance of the NucliSens EasyQ assay (bioMerieux) combined with the manual NucliSens miniMag extraction methodology to the Roche Cobas Ampliprep/Standard Amplicor Monitor methodology (Roche Diagnostics) for HIV-1 RNA quantitation in HIV-1-infected individuals in South Africa. Plasma samples (284) from HIV sero-positive patients at different stages of infection were analyzed. The distribution of results was typical of the clinical samples received at the laboratory where 20% have viral load results <400 copies/ml (2.6 log) and 18% have viral load results >750000 copies/ml (5.8 log) using the Roche Amplicor Monitor standard assay. All statistical analyses were performed using log10-transformed values for all the variables in the analyses, i.e. log10EasyQIU/ml, and log10RNA (log10 copies/ml, Amplicor). Roche values were converted from RNA copies per ml to IU/ml by multiplying the Roche value by 0.51. HIV RNA levels quantitated by the NucliSens EasyQ assay correlated significantly with those of the Roche Cobas Amplicor Monitor assay (r=0.874, p<0.0001). Reproducibility of the NucliSens EasyQ assay in the log6IU range yielded CV variance of 1.3-2.84% for two well-trained technologists. In addition, a retrospective evaluation of the performance of the NucliSens EasyQ assay in 102 runs (2448) samples was conducted in the laboratory over a 4-month interval. Factors considered during this evaluation included time taken to perform the assay, volume requirements, number of required repeats, potential for contamination.  相似文献   

8.
BACKGROUND: Monitoring anti-retroviral therapy requires that viral load assays for human immunodeficiency virus type 1 (HIV-1) be applicable to diverse HIV-1 subtypes. OBJECTIVES: To evaluate NucliSens EasyQ HIV-1 assay for quantitation of common HIV-1 subtypes prevalent in South-east Asia. STUDY DESIGN: One hundred and nineteen plasma samples collected in Hong Kong and Cambodia were used to compare the performance of NucliSens EasyQ HIV-1 and COBAS Amplicor HIV-1 Monitor version 1.5 assays. Viral RNA extracted from the NucliSens MiniMAG was also used for HIV-1 subtyping. RESULTS: Performance of NucliSens EasyQ correlated well with COBAS Amplicor (r=0.777, p<0.001) and the small mean difference (0.0462log(10)IU/mL) obtained in the Bland and Altman model indicated good agreement between two assays. The NucliSens EasyQ assay demonstrated a 95% sensitivity at 500IU/mL and 100% specificity. Reproducibility of this assay was within log(10)2-4IU/mL and had a coefficient of variation between 2.3% and 10.4%. Among the 109 specimens included in the analysis, HIV-1 subtyping identified 64 CRF01_AE, 38 subtype B, 3 subtype C, 3 CRF07_BC and 1 subtype G viruses. CONCLUSIONS: Performance of NucliSens EasyQ was comparable to COBAS Amplicor for HIV-1 viral load monitoring. RNA extracts from NucliSens MiniMAG could be used for HIV-1 viral load monitoring, subtyping and drug resistance mutations detection. Our findings highlight the versatility of both NucliSens EasyQ and COBAS Amplicor in monitoring prevalent subtypes and rare circulating recombinant forms (CRFs) in the South-east Asia region.  相似文献   

9.
10.
HIV-1 is characterised by extensive genetic variability encompassing at least 10 different phylogenetically related clades within the major group of HIV-1 subtypes. Most commercially available HIV-1 RNA plasma viral load assays have been optimised with clade B viruses and may yield misleadingly low RNA levels for nonclade B viruses that are increasingly found in Europe. In this study we compare the most recent versions of the Roche Amplicor HIV Monitor and the Chiron Quantiplex for ability to detect viraemia in a population of patients infected with a range of HIV-1 subtypes. EDTA-treated plasma was obtained from 206 patients. The Amplicor and Quantiplex assays were carried out in accordance with manufacturers' instructions. Results from 53/206 (25.7%) samples differed by >0.4 log between Amplicor 1.5 and Quantiplex 3.0. A >0.5 log and 1.0 log difference was detected between Amplicor 1.5 and Quantiplex 3.0 in 37/206 (17.9%) and 7/206 (3.4%) of samples, respectively. Overall, Amplicor 1.5 gave a median value of 0.22 log higher than Quantiplex 3.0. Discordant results were detected in 53 out of 206 (25.7%) samples. Of these 22 out of 123 (17.9%) samples were of UK origin, 18 out of 43 (41.9%) African, 1 out of 8 (12.5%) South American, 1 out of 6 (16.7%) North American, 4 out of 9 (44.4%) North European, 3 out of 11 (23.7%) South European and 3 out of 7 (42.3%) Asian samples, respectively. Serotyping revealed that discordant viral load results between Amplicor 1.5 and Quantiplex 3.0 occurred within samples from all subtypes (A-E). Despite the improvements made to both the Roche Amplicor and the Chiron Quantiplex assays discordant results were detected between the two assays in 25.7% of cases. In a substantial minority of patients there were major discrepancies between the two assays that were not explained by HIV subtype differences.  相似文献   

11.
Eleven laboratories evaluated the use of dried blood and plasma spots for quantitation of human immunodeficiency virus (HIV) RNA by two commercially available RNA assays, the Roche Amplicor HIV-1 Monitor and the bioMerieux NucliSens HIV-1 QT assays. The recovery of HIV RNA was linear over a dynamic range extending from 4,000 to 500,000 HIV type 1 RNA copies/ml. The Monitor assay appeared to have a broader dynamic range and seemed more sensitive at lower concentrations. However, the NucliSens assay gave more consistent results and could be performed without modification of the kit. HIV RNA was stable in dried whole blood or plasma stored at room temperature or at -70 degrees C for up to 1 year. Dried blood and dried plasma spots can be used as an easy and inexpensive means for the collection and storage of specimens under field conditions for the diagnosis of HIV infection and the monitoring of antiretroviral therapy.  相似文献   

12.
Human immunodeficiency virus (HIV) RNA testing is the gold standard for monitoring antiretroviral therapy in HIV-infected patients. However, equipment and reagent costs preclude widespread use of the assay in resource-limited settings. The Perkin-Elmer Ultrasensitive p24 assay and the Cavidi Exavir Load assay both offer potentially simpler, less costly technologies for monitoring viral load. These assays were compared to the Roche Amplicor HIV-1 Monitor Test, v1.5, using panels of clinical samples (subtype B) from HIV-positive subjects and HIV-spiked samples (subtypes A, C, D, CRF_01AE, CRF_02AG, and F). The Ultrasensitive p24 assay detected 100% of the spiked samples with virus loads of >250,000 copies/ml and 61% of the clinical samples with virus loads of 219 to 288,850 copies/ml. Detection rates were improved substantially if an external lysis buffer was added to the procedure. The Cavidi assay detected 54 to 100% of spiked samples with virus loads >10,000 copies/ml and 68% of the clinical samples. These detection rates were also greatly improved with a newly implemented version of this kit. Coefficients of variation demonstrate good reproducibility for each of these kits. The results from the Cavidi v1.0, Cavidi v2.0, and Perkin-Elmer, and the Perkin-Elmer Plus external buffers all correlated well with the results from the Roche Monitor Test (r = 0.83 to 0.96, r = 0.84 to 0.99, r = 0.58 to 0.67, and r = 0.59 to 0.95, respectively). Thus, the use of these two assays for monitoring patients, together with less-frequent confirmation testing, offers a feasible alternative to frequent HIV RNA testing in resource-limited settings.  相似文献   

13.
BACKGROUND: Most of the quantitation assays for HIV-1 RNA used currently are designed and optimized for HIV-1 subtype B viruses and hence may not be suitable for India, where the predominant subtype is HIV-1 subtype C. OBJECTIVES: Development and standardization of HIV-1 TaqMan real time PCR assay suitable for measuring plasma and CSF viral RNA levels in HIV subtype C infected individuals. STUDY DESIGN: A TaqMan real time PCR was developed using primers and probes selected in the gag region for detection of Indian HIV-1 subtype C strain. Plasma (n=120) and CSF samples (n=46) obtained from HIV infected subjects were used to evaluate the sensitivity and specificity of the assay. A comparative evaluation was carried out with a commercially available quantitative HIV viral load assay (Roche Amplicor Version 1.5). RESULTS: The TaqMan assay was able to amplify all HIV-1 group M subtypes except subtype E. Viral loads could be estimated in all the plasma (n=120) and 40/46 CSF samples obtained from HIV positive subjects. Sensitivity of this assay was found to be 180 copies/ml. Correlation with the commercially available viral load assay was very good (r=0.885). CONCLUSIONS: A TaqMan real time PCR was standardized for HIV-1 subtype C and it was more sensitive (180 copies/ml) than standard Amplicor monitor assay, Version 1.5 (400 copies/ml).  相似文献   

14.
The Nuclisens EasyQ HIV-1 v1.1 assay (Biomerieux) is a real-time detection method combined with NASBA technology designed to measure plasma HIV-RNA. Its performance was assessed in 1008 clinical specimens collected from individuals infected with clade B (774) and non-B (234) HIV-1 variants at four European laboratories. The results were compared with those obtained using three other commercial viral load assays: Cobas Amplicor Monitor HIV-1 v1.5 (Roche), Versant HIV-1 RNA assay (Bayer) and Nuclisens HIV-1 QT (Biomerieux). Overall, the linearity, specificity and reproducibility of the EasyQ assay was comparable with that from the other tests. The correlation coefficient (R) between methodologies was 0.85 for Amplicor; 0.87 for Versant; and 0.91 for Nuclisens. The specificity of the assay was 99.4%. Of note, Versant missed 17% of specimens with non-B subtypes which could be detected by EasyQ, while Amplicor provided similar results than EasyQ. HIV-1 group O specimens were only detected by the EasyQ assay. In conclusion, the performance of the EasyQ assay seems to be similar to that of other HIV-1 viral load tests currently on the market, but it is more sensitive than Versant for HIV-1 non-B subtypes and shows a wider dynamic range than Amplicor. Moreover, as it incorporates the advantage of real-time detection procedures, it facilitates high throughput and short turnaround time.  相似文献   

15.
16.
17.
The COBAS TaqMan HIV-1 test (Roche Diagnostics) was compared with the LCx HIV RNA quantitative assay (Abbott Laboratories), the Versant HIV-1 RNA 3.0 (bDNA) assay (Bayer) and the COBAS Amplicor HIV-1 Monitor v1.5 test (Roche Diagnostics), using plasma samples of various viral load levels from HIV-1-infected individuals. In the comparison of TaqMan with LCx, TaqMan identified as positive 77.5% of the 240 samples versus 72.1% identified by LCx assay, while their overall agreement was 94.6% and the quantitative results of samples that were positive by both methods were strongly correlated (r=0.91). Similarly, in the comparison of TaqMan with bDNA 3.0, both methods identified 76.3% of the 177 samples as positive, while their overall agreement was 95.5% and the quantitative results of samples that were positive by both methods were strongly correlated (r=0.95). Finally, in the comparison of TaqMan with Monitor v1.5, TaqMan identified 79.5% of the 156 samples as positive versus 80.1% identified by Monitor v1.5, while their overall agreement was 95.5% and the quantitative results of samples that were positive by both methods were strongly correlated (r=0.96). In conclusion, the new COBAS TaqMan HIV-1 test showed excellent agreement with other widely used commercially available tests for the quantitation of HIV-1 viral load.  相似文献   

18.
19.
20.
Quantification of HIV-1 subtypes is essential for appropriate clinical management. Whereas viral load assays were initially developed to accurately quantify subtype B, the recent worldwide spread of non-B subtypes and the introduction of treatment programs in regions with non-B subtypes have prompted adaptations of these assays. The Bayer Versant HIV-1 RNA 3.0 Assay (branched DNA [bDNA] 3.0) and the Roche Amplicor HIV-1 Monitor version 1.5 (Amplicor 1.5) assays are reported to quantify all subtypes in group M; however, evaluation of performance characteristics remains limited. In this study, we evaluated the accuracy and reliability of bDNA 3.0 and Amplicor 1.5 on multiple serially diluted viral isolates from HIV-1 group M, subtypes A through F. Testing was conducted on both assay systems in two independent laboratories. Comparative pansubtype quantification from regression analysis showed that quantification by bDNA 3.0 was approximately 0.3 log-fold lower than that by Amplicor 1.5. Comparative pansubtype accuracy analysis showed data points more closely distributed about their respective regression lines and thus showing greater reliability by bDNA 3.0 than by Amplicor 1.5.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号