首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
目的 探讨钆喷酸葡胺(gadopentetate dimeglumine,Gd-DTPA)提高磁共振胰胆管成像(magnetic resonance cholangiopancreatography,MRCP)图像质量的可行性.方法 纳入临床疑有胰胆管病变行MRI检查患者32例,在注射Gd-DTPA前及注射后5 min分别行2D MRCP扫描,比较:①左、右肝管,胆囊,胆总管,胰管,肝脏实质及胰腺实质的信噪比(signal-to-noise ratio,SNR),对比度噪声比(contrast-to-noise ratio,CNR)及对比率(contrast ratio,CR)在增强前后的变化;②胰胆道系统解剖结构在增强前后的显示效果变化.结果 肝脏、胰腺增强后的SNR较增强前明显降低(P<0.05),而左右肝管、胆总管、胆囊、胰管的CR2(相较胰腺)在注射Gd-DTPA后明显增高(P<0.05).Gd-DTPA增强后的胆囊、左右肝管、肝管、胆总管、胰管的显示明显优于增强前(P<0.05).结论 静脉注射Gd-DTPA增强能抑制胰胆道周围组织的信号,有利于提高胰胆道树的对比度,提高MRCP图像质量.  相似文献   

2.
口服钆喷替酸葡甲胺溶液行MR胰胆管成像的初步临床应用   总被引:21,自引:1,他引:21  
目的 应用口服钆喷替酸葡甲胺 (Gd DTPTA)溶液作为胃肠道阴性对比剂 ,以降低胃肠道背景高信号 ,提高磁共振胰胆管成像 (MRCP)的图像质量。方法 用 5 0ml药瓶将Gd DTPA溶液稀释成不同浓度 (分别稀释为 5倍、10倍、15倍、2 0倍 ) ,并设空白对照组 ,行常规及MRCP扫描 ,以选择最佳的对比剂浓度。对 15例疑有胰胆管系统疾病的病人行口服对比剂前后MRCP检查 ,对比剂为稀释 5倍的Gd DTPA溶液 ( 1 488g/L) 2 5 0ml,磁场强度为 1 5T。MRCP成像方法有二维单层快速自旋回波 (FSE)序列及半傅立叶单次激发快速自旋回波 (HASTE)序列。结果 实验部分结果表明稀释 5倍的Gd DTPA溶液T2 WI信号降低最明显 ,达 5 9 3 % ,HASTE序列信号强度降低 82 45 % ,单层MRCP时所有稀释倍数液体信号强度均下降达 90 %以上。所有病例口服对比剂后MRCP扫描胃及十二指肠内液体高信号均较前有明显下降 ,图像质量明显提高 ,以单层MRCP序列胃肠道液体高信号抑制最明显。口服Gd DTPA溶液前后 ,胆总管、胰管及胆囊结构的显示程度等级评分差异有显著性意义 (P <0 0 5 )。结论 稀释 5倍的口服Gd DTPA溶液是一种安全有效地降低胃肠道液体高信号强度、改善MRCP图像质量的胃肠道阴性对比剂  相似文献   

3.
目的探讨3.0T磁共振在腹部胰胆管水成像中优势及其应用。方法搜集我院2011年1月~2011年4月进行腹部磁共振检查的患者50例,采用西门子Verio3.0T磁共振,8通道相阵控腹部线圈,haste序列,spair序列及MRCP胰胆管成像序列进行轴位相扫描。结果采用3.0T磁共振的haste序列能够在自由呼吸的状态下,缩短扫描时间同时获得高质量的图像;spair序列具有很好的脂肪抑制效果,能极大的提高对病变的显示;与haste技术结合的MRCP序列能对胰管、肝内胆管、胆囊、胆总管的病变显示的更加清楚。结论西门子3.0T磁共振并行采集技术及haste、spair序列在腹部扫描中,能获得高质量的图像。  相似文献   

4.
目的:评价马根维显(Gd—DTPA)溶液作为胃肠道阴性对比剂对改善磁共振胰胆管成像(MRCP)质量的价值。方法:对30例疑有胰、胆管系统疾病的患者口服对比剂前后分别行常规腹部MR和MRCP检查,采用相同的扫描参数及定位。结果:所有病例口服对比剂后MRCP扫描,胃及十二指肠内液体高信号均较前有明显下降,图像质量明显提高。口服稀释的Gd—DTPA溶液前后,MRCP检查胆总管、胰管及胆囊结构的显示效果具有显著性意义(P〈0.05)。结论:口服稀释的Gd—DTPA溶液是一种安全有效降低胃肠道液体高信号强度、改善MRCP图像质量的方法。  相似文献   

5.
目的 选择出静脉用钆喷替酸葡甲胺(Gd-DTPA)作为MR胰胆管成像(MRCP)口服胃肠道阴性对比剂的最佳浓度及容量;评价口服Gd-DTPA对比剂在抑制胃肠道高信号、改善MRCP图像质量中的作用.方法 (1)体外实验:对不同浓度Gd-DTPA稀释液及温开水空白对照组行T1WI、T2WI、二维单层快速自旋回波(FSE)序列及三维半傅立叶单次激发快速自旋回波(HASTE)序列扫描,测量不同成像序列上的信号强度并计算增强率,选择出最佳浓度;(2)临床实验:分别配制不同容量的最佳浓度Gd-DTPA稀释液作为MRCP口服胃肠道阴性对比剂,选择出最佳容量;以最佳浓度和容量Gd-DTPA对比剂对24例临床疑有胰胆管病变的患者行口服前及口服后5~10、10~15 minMRCP扫描,分析图像质量.统计方法采用计算机软件包SPSS 10.0版,对实验结果进行方差分析.结果 T1WI上对照组均为低信号,Gd-DTPA浓度≤0.01 mol/L时为完全高信号;T2WI上对照组为明亮高信号,Gd-DTPA浓度≥0.015 mol/L为完全低信号;2D FSE单层MRCP图像上对照组为明亮高信号,Gd-DTPA浓度在0.0025~0.0300 mol/L之间均为低信号;3D HASTE MRCP图像上对照组为明亮高信号,Gd-DTPA浓度≥0.01 mol/L时为完全低信号;容量≥100 ml浓度为0.01 mol/L的Gd-DTPA对比剂对胃及十二指肠内液体高信号的抑制效果完全;24例患者口服100 ml浓度为0.01 mol/LGd-DTPA对比剂10~15 min后MRCP图像上肝内1、2、3级胆管、肝总管、胆囊、胆总管、胰管头、体、尾的平均等级分数(分别为3.63、3.46、3.08、3.71、3.87、3.88、3.79、3.71、3.50)略高于5~10 min的图像(分别为3.54、3.46、3.00、3.79、3.96、3.87、3.71、3.67、3.54),差异无统计学意义(P值均>0.05),而口服对比剂后肝内3级胆管、胆总管、胰管的等级分数明显高于口服对比剂前(分别为2.79、3.71、3.50、3.42、3.25),差异有统计学意义(F值分别为4.36、4.75、7.86、8.05、7.55,P值均<0.05).结论 100 ml浓度0.01 mol/L的Gd-DTPA对比剂能使胃及十二指肠内潴留液高信号抑制完全,可作为MRCP理想的胃肠道阴性对比剂;口服对比剂后5~10 min行MRCP扫描,图像质量效果最佳.  相似文献   

6.
目的:对比磁共振胰胆管成像和钆贝葡胺(Gadobenate Dimeglumine)增强胆道成像对肝胆管的显示能力.材料与方法:2006-03~2009-04解放军总医院行活体半肝移植的供体64例,术前在GE SIGNA-EXCITE 3.0T扫描仪上行冠状位厚层单击发快速自旋回波(2D-SSFSE)、3D快速自旋回波容积扫描(3D-FRFSE)及肝特异性造影剂钆贝葡胺增强胆管成像的肝脏快速三维容积采集序列(3D-LAVA)扫描,在GE 4.3图像工作站行MIP后处理重建胆道系统,对比三种方法肝胆管显示能力并与术中所见对照.结果:三种成像方式显示胆总管、胆囊、肝总管、肝内一级胆管效果的差异无显著性意义(P〉0.5).3D-FRFSE对肝内三级以上胆管显示优于2D-SSFSE和钆贝葡胺造影(P〈0.05),而肝胆管钆贝葡胺造影在诊断肝胆管解剖变异方面优于2D-SSFSE和3D-FRFSE序列.结论:肝特异性造影剂钆贝葡胺可单独用于肝胆管成像,与常规磁共振胰胆管成像联合应用有利于提高胆道显示的满意度.  相似文献   

7.
目的分析口服稀释静脉用钆喷酸葡胺溶液作为低场强磁共振胃肠道阴性对比剂及联合静脉注射钆喷酸葡胺磁共振胆胰管成像(MRCP)在低场MR中用于显示胆胰管及疾病的能力。方法 30例临床可疑有胆胰管病变的患者,均有不同程度胆系梗阻、腹痛、不同程度皮肤或巩膜黄染等,部分有腹部肿块,均行MR平扫、Gd-DTPA(钆喷酸葡胺)强化检查,部分同时行超声及CT检查。结果 30例受检者均能清楚显示胆胰管树,并能清晰显示病变位置,其中18例发现肝内胆管占位,10例发现肝内胆管、肝外胆管及(或)胆囊结石,2例胰头占位。结论口服钆喷酸葡胺溶液可抑制胃及十二指肠内潴留液的高信号以及胆胰管树背景的小血管信号,改善MRCP图像的质量,结合肝胆MR平扫、强化应用具有较高的肝内、外胆管显示率及肝内、外胆管病变的显示能力,能为胆胰管病变的诊断及鉴别诊断提供更多帮助。  相似文献   

8.
胃肠道阴性对比剂在磁共振胰胆管成像中的应用研究   总被引:3,自引:1,他引:2  
目的 研究胃肠道阴性对比剂在改善磁共振胰胆管成像 (MRCP)质量的应用。方法 体外实验 :将马根维显 (Gd -DTPA)和欧乃影注射液分别用温开水稀释为不同浓度制剂盛入 10ml注射器内 ,以温开水作空白对照 ,然后行MRCP扫描 ,以获取对比剂最佳稀释倍数。临床实验 :对 3 9例临床疑胰胆管系统疾病申请MRCP检查患者行口服稀释 3 0 0倍马根维显溶液前后常规腹部MR和MRCP检查 ,扫描参数及定位完全相同。结果 体外实验 :稀释 3 0 0倍的马根维显溶液和稀释 2 0 0倍的欧乃影溶液为最佳浓度。临床实验 :所有病例口服稀释 3 0 0倍的马根维显溶液后 ,胃与十二指肠内的液体高信号被明显抑制 ,MRCP胆管显示效果对比在服对比剂前后具有显著性意义 (P <0 .0 5 )。结论 口服稀释 3 0 0倍的马根维显溶液作为胃肠道阴性对比剂可有效地改善MRCP图像的质量。  相似文献   

9.
目的:探讨改良快速自旋回波在胰胆管MRI成像中的临床应用价值。材料与方法:3例胆囊摘除术后,4例胆结石,1例肝硬化并肝功能不全患者以及2名健康志愿者。应用改良快速自旋回波和脂肪抑制序列行MRI检查,被检者屏气18s进行信号采集,经过重建而获得胰胆管成像。结果:胆囊(除3例已摘除外)7例中显示6例,1例胆囊内充满结石而不显示,胆总管,肝总管及左右肝管分别显示9例,主胰腺管显示3例。胆囊结石3例被检出,表现为胆囊内大小不等之圆形低信号区。结论:应用改良快速自旋回波技术,减少信号采集时间,缩短了MR胰胆管成像中患者的屏气时间,同样能清晰地显示胰胆管系统并对胰胆道疾病作出诊断  相似文献   

10.
目的评价新型磁对比剂钆贝葡胺(Gd-BOPTA)在肝脏占位病变中的诊断价值。方法对10例B超及CT检查提示有肝占位性病变病例进行常规MRI检查和用Gd-BOPTA增强后立即扫描以及30min、60min、90min、120min扫描,有2例延迟至6h和24h扫描。扫描序列SET1WI、FSET2WI平扫、3D-SPGRT1及SET1WI进行动态和延迟扫描。平扫观察病变与正常肝脏组织在各个序列图像上的信号及对比。使用Gd-BOPTA增强后观察,肝实质的强化特征及比较两种扫描序列对肝脏病灶的显示情况,动态及延迟双期扫描的病灶强化特点及形态学的改变。结果使用Gd-BOPTA增强检查后,发现8例肝癌,2例血管瘤,肝实质长时间保持持续强化稳定状态,最高峰为60min,最长强化时间达24h,GRE较SE在肝脏病变的显示中更有优势,通过双期扫描,病灶显示的更清晰,诊断更明确。结论作为非特异性钆剂的新一代顺磁性对比剂,Gd-BOPTA对肝脏的强化持久稳定,通过动态和延迟的双期扫描能提高肝脏占位病变检出的敏感性和特异性,是一种具有良好发展前景的磁共振对比剂。  相似文献   

11.
目的:探讨磁共振胰胆管成像(MRCP)在婴幼儿胆管疾患的诊断价值.方法:搜集本院2004年4月~2005年9月行MRCP检查并经手术病理证实的47例婴幼儿胆管疾患的病例进行回顾性分析.结果:胆管闭锁22例;胆汁黏稠综合征1例;先天性胆管扩张症24例,其中合并胰胆管合流、胆石症、胆泥沉积症各1例.MRCP能直接显示胆管树及胰管的形态,明确胆管闭锁、扩张、梗阻的部位、范围,定性诊断率达95.6%.结论:MRCP不用对比剂,无损伤,在婴幼儿胆管疾患的诊断中敏感性及定性诊断率高,是首选诊断方法.  相似文献   

12.
ObjectiveTo compare the diagnostic performance and interobserver agreement between contrast-enhanced computed tomography (CECT) and contrast-enhanced magnetic resonance imaging (CE-MRI) with magnetic resonance cholangiopancreatography (MRCP) for evaluating the resectability in patients with extrahepatic cholangiocarcinoma (eCCA).Materials and MethodsThis retrospective study included treatment-naïve patients with pathologically confirmed eCCA, who underwent both CECT and CE-MRI with MRCP using extracellular contrast media between January 2015 and December 2020. Among the 214 patients (146 males; mean age ± standard deviation, 68 ± 9 years) included, 121 (56.5%) had perihilar cholangiocarcinoma. R0 resection was achieved in 108 of the 153 (70.6%) patients who underwent curative-intent surgery. Four fellowship-trained radiologists independently reviewed the findings of both CECT and CE-MRI with MRCP to assess the local tumor extent and distant metastasis for determining resectability. The pooled area under the receiver operating characteristic curve (AUC), sensitivity, and specificity of CECT and CE-MRI with MRCP were compared using clinical, surgical, and pathological findings as reference standards. The interobserver agreement of resectability was evaluated using Fleiss kappa (κ).ResultsNo significant differences were observed between CECT and CE-MRI with MRCP in the pooled AUC (0.753 vs. 0.767), sensitivity (84.7% [366/432] vs. 90.3% [390/432]), and specificity (52.6% [223/424] vs. 51.4% [218/424]) (P > 0.05 for all). The AUC for determining resectability was higher when CECT and CE-MRI with MRCP were reviewed together than when CECT was reviewed alone in patients with discrepancies between the imaging modalities or with indeterminate resectability (0.798 [0.754–0.841] vs. 0.753 [0.697–0.808], P = 0.014). The interobserver agreement for overall resectability was fair for both CECT (κ = 0.323) and CE-MRI with MRCP (κ = 0.320), without a significant difference (P = 0.884).ConclusionCECT and CE-MRI with MRCP showed no significant differences in the diagnostic performance and interobserver agreement in determining the resectability in patients with eCCA.  相似文献   

13.
比较单次激发磁共振胰胆管成像(SSMRCP)和常规磁共振胰胆管造影(CMRCP),评价SSMRCP的临床应用 价值。材料与方法81例梗阻性黄疸、1例胆管-空肠吻合术后及61例无黄疸患者行OMRC、SSMRC单层及多层扫描, 比较两种技术诊断的准确性。结果三个序列均能显示胆管病变部位、疾病特征、近侧扩张胆管以及远侧正常胰胆管;显 示扩张胆管直径三个序列间没有显著性差异;SSMRCP多层显示胆管病变细节较好,而SSMRCP单层显示胰管则明显优 于另两种方法。结论SSSMRCP可代替OMRCP,准确地、更快速地诊断胆管系统疾病,并能更好地显示正常胰管。  相似文献   

14.
磁共振胆胰管成像(MRCP)中成像方法的选择   总被引:11,自引:0,他引:11  
目的:研究磁共振胆胰管成像(MRCP)时,应用胃肠道阴性对比剂(葡萄糖酸亚铁糖浆)后,不同成像方法的优,缺点。方法:50例受检者口服12% V/V葡萄糖酸亚铁糖浆后进行MRCP检查;采用GE1.5T MRI扫描机,常规薄层MIP成像及厚层单次激发成像(Single-Shot),薄层单次激发MIP成像。结果:随着TE时间的延长,葡萄糖酸亚铁糖浆对胃肠道液体信号的抑制作用增强,使MRCP时胆胰管显影更加清晰,尤其在单次激发成像时,结合MIP与厚层单次激发图像可以得到更多信息。结论:口服胃肠道4阴性对比剂后行MRCP检查,能够抑制胃肠道内液体信号,使胆胰管显影更加清晰,特别是在单次激发成像时。  相似文献   

15.
磁共振胆管胰管成像的临床应用研究   总被引:2,自引:0,他引:2  
目的:探讨快速自旋回波(FSE)及单次激发快速自旋回波(SSFSE)对磁共振胆胰管成像(MRCP)的临床应用价值。材料与方法:分析应用FSE对35例胆道系统病变及正常志愿者的MRCP检查,其中21例行SSFSE并与FSE行对照观察:结果:仅用FSE行MRCP的14例中,9例扩张的胆管经后处理显示清楚,3例显示胰管,5例无扩张的胆道显示不满意。同时用FSE和SSFSE扫描21例,对胆管梗阻部位和扩张胆管的显示无显著差异;SSFSE对无扩张胆、胰管的显示分别是74.4%、52.4%,显著高于FSE的16.6%、0.9%,对胆囊显示二者相似。结论:梗阻性胆胰管扩张者,FSE和SSFSE均可得到满意结果,而正常无扩张胆胰管的显示,SSFSE较FSE好  相似文献   

16.
阴性胃肠道造影剂在磁共振胆胰管成像(MRCP)中的应用   总被引:5,自引:0,他引:5  
目的:研究阴性胃肠道造影剂在磁共振胆胰管成像(MRCP)中的应用效果。材料和方法:对照研究不同浓度的硫酸钡溶液和葡萄糖酸亚铁糖浆溶液在MRCP中对胃肠道液体信号的影响:共45例受检者,每例均行不同TE时间下的常规MRCP(MIP)及单次激发成像(Single-Shot)检查。检查前,15例口服硫酸钡溶液,15例口服葡萄糖酸亚铁糖浆溶液,15例未口服造影剂作对照。结果:50%W/V硫酸钡溶液、12%V/V葡萄糖酸亚铁糖浆溶液在各组中对胃肠道液体信号的抑制效果理想。在采用长TE时间的情况下,钡剂及铁剂溶液的信号低于采用短TE时间。结论:应用阴性胃肠道造影剂能够消除或明显抑制胃肠道内液体的高信号,提高MRCP的图象质量。铁剂优于钡剂,特别是在单次激发成像时。  相似文献   

17.
王冬女  汪军峰  朱华勇  肖明   《放射学实践》2009,24(11):1240-1242
目的:探讨磁共振胰胆管成像(MRCP)显示胆囊罗-阿窦(RAS)的影像学表现及其病理特征.方法:45例胆囊腺肌增生症(GBA)患者,术前均行MRCP检查,常规采用单次激发FSE(SS-FSE)重T2WI序列和稳态采集快速成像(FIESTA)序列行冠状面扫描.将45例患者的MRCP表现和病理学资料进行对照,分析罗-阿窦的影像学特征及其病理基础.结果:45例中MRCP显示胆囊壁局限性变形、增厚43例,弥漫性增厚2例;增厚的胆囊壁内均见多个小囊状憩室样结构环状排列呈典型的"花环征",其内呈高信号.术后病理诊断为GBA并慢性胆囊炎45例,其中35例合并胆囊结石;罗-阿窦的病理表现为肌层内异位腺体,周围有增生的平滑肌组织环绕或伴神经纤维增生性改变.结论:MRCP可清晰显示GBA伴慢性胆囊炎患者胆囊壁罗-阿窦的形态特征,正确选择敏感无创的影像学检查方法和仔细观察罗-阿窦形态特征是GBA早期诊断和治疗的关键.  相似文献   

18.
磁共振胰胆管成像对诊断胆胰系统疾病的临床应用价值   总被引:12,自引:4,他引:8  
目的评价磁共振胰胆管成像(MRCP)技术在胆胰系统疾病诊断中的应用价值.方法68例患者进行了MRCP检查,其中正常对照组11例,各种胰胆管病变组57例.扫描使用ELSCINTSGR2.0T超导磁共振成像仪,体线圈及呼吸门控触发技术.平扫采用自旋回波(SE)常规成像;MRCP采用快速自旋回波(FSE)重T2加权像进行薄层扫描.所得图像用最大强度投影法(MIP)进行三维(3D)重建.结果MRCP能清晰显示胰胆管的解剖结构,对胆道梗阻程度和梗阻部位判断的确诊率达100%,梗阻原因的确诊率达91.2%.结论MRCP检查的成功率高,胰胆管解剖结构显示清晰,适应于各种胰胆管疾病的诊断,可作为该系统疾病诊断的首选方法  相似文献   

19.
口服枸橼酸铁铵在胆胰系MRI中的应用价值评价   总被引:1,自引:0,他引:1       下载免费PDF全文
目的:评价口服枸橼酸铁铵在胆胰系MRI中的应用价值。方法:对86例怀疑有胰胆管系统疾病的患者行口服枸橼酸铁铵前、后MRCP及常规胆胰系MRI,对服用对比剂前后MRCP图像质量、邻近脏器边缘分辨力及各序列上胃十二指肠腔与肝脏的对比噪声比进行自身对照研究,由资深放射科医生对两组图像进行评价,SPSS统计软件进行统计分析。结果:服用对比剂后TrueFISP及HASTE序列均显示胃、十二指肠腔内信号显著降低,形成阴性对比;而FL2D序列胃、十二指肠腔内信号增强,形成阳性对比;胃十二指肠腔内液体造成的背景高信号被完全抑制,单层法与多层法MRCP图像质量及邻近的肝胆胰等结构边缘分辨力均明显提高。结论:口服枸橼酸铁铵能明显提高胆胰系MRI的成像质量,对诊断胆胰系病变具有重要的临床应用价值。  相似文献   

20.
赵红兰  徐凯  刘颖  汪秀玲  路欣  席建宁   《放射学实践》2009,24(6):629-632
目的:探讨不同序列在乳腺MR成像中的应用价值。方法:对10名健康志愿者和42名乳腺疾病患者分别采用FSE-IR、FSE-XL T1WI、FSE-XL T2WI和3D-FSPGR序列进行乳腺MR成像,从图像信噪比、对比噪声比、病灶显示数目等方面对其应用价值进行评价。结果:抑脂条件下,FSE-IR和FSE-XL T2WI图像信噪比和对比噪声比明显高于FSE-XL T1WI,差别均有显著性意义(P〈0.05);FSE-IR序列图像对比噪声比高于FSE-XL T2WI,差别有显著性意义(P〈0.01),两者之间的信噪比差别无显著性意义(P〉0.05)。42例患者采用上述序列联合检出45处病变,其中恶性3例,共5处病变;良性34例,共40处病变。不同序列对病变的检出率分别为FSE-IR93.33%(42/45)、FSE-XL T2WI93.33%(42/45)、FSE-XL T1WI42.22%(19/45)、3D-FSPGR T1WI动态增强为82.22%(37/45)。结论:3.0TMR乳腺成像,联合使用FSE-IR、非抑脂FSE-X LT1WI序列横轴面、抑脂FSE-XL T2WI矢状面平扫和3D-FSPGR动态增强,可在较短的扫描时间内获得优质的扫描图像,提高对病变的检出率。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号