Transcatheter closure of patent ductus arteriosus (PDA) is now a well-established treatment alternative to surgery in many cardiology centers. Of all the methods used, transcatheter coil occlusion is the preferred therapy. For small PDA, the method using 0.038" Gianturco coils has proven safe and effective. However, this therapeutic strategy has encountered some difficulties with large PDA. This study provides an alternative strategy, using 0.052" Gianturco coil and complete closure of residual shunt with multiple coils to close large PDA. Fifteen patients underwent transcatheter coil occlusion of large ( > or = 4mm) patent ductus arteriosus. The intermediate success rate was 86.7%. There were four complications and only two patients had to be referred for surgery.  相似文献   

2.
BACKGROUND: The aim of this study was to report the initial experience of using the Gianturco coil (Cook Cardiology, Bloomington, Indiana) without heparinization to close patent ductus arteriosus (PDA). PATIENTS AND METHODS: Forty consecutive patients (30 females, 10 males) underwent transcatheter closure of a PDA via the right femoral artery approach without heparinization. Patients ages ranged from 7 months to 55 years (median, 6.8 years); weights ranged from 7.8 65 kg (median, 18.3 kg). Twenty-one patients had cardiomegaly (n = 21), congestive heart failure (n = 10), or both (n = 10). The PDAs measured 0.8 4.5 mm (median, 2.6 mm) at the narrowest diameter; the mean Qp/Qs ranged from 1.0 2.6 (1.4 +/- 0.4). The helical diameter of the coil that we chose was 1.7 times the narrowest PDA diameter. The length of the coil was sufficient to produce 4 or 5 loops. RESULTS: Successful coil placement was accomplished in all 40 patients. Thirty-five patients (87.5%) underwent single coil implantation, 2 patients (5%) had 2 coils, and 3 patients (7.5%) had 3 coils. Complete ductus occlusion was achieved in 80% of cases at the end of the procedure, while 8 patients had minimal shunt detected by aortography or echocardiography. The occlusion rate increased to 87.5% by the next day, 90% by 1 month, 92.5% by 3 months, 95% by 6 months, and 97.5% by 9 and 12 months. Only one asymptomatic patient had minimal residual shunt detected by color Doppler at 12 months follow-up. At a median follow-up of 17 months (range, 5 25 months), no patient had thromboembolism, endocarditis, coil migration, diminished femoral pulse or hemolysis. CONCLUSION: Our preliminary results suggest that retrograde transcatheter closure of PDA with the Gianturco coil without heparinization is feasible, safe and efficacious. A single coil allowed complete occlusion of PDA 3 mm in diameter.  相似文献   

3.
Coil closure of patent ductus arteriosus (PDA) has become an accepted alternative to surgical closure in most pediatric cardiac centers. However, little is known about the mid- to long-term outcome of this procedure. Therefore, we evaluated the immediate, short-, and long-term outcome of transcatheter coil closure (TCC) of PDA using single or multiple Gianturco coils or the Gianturco-Grifka Vascular Occlusive Device (GGVOD). One hundred forty-nine patients underwent an attempt at TCC of their PDAs at a median age of 2.4 years (2 weeks to 55 years) and median weight of 13.5 kg (2.3–87 kg). There were 33 patients < 1 year of age. The median PDA minimal diameter was 2 mm (0.4–7 mm) with 26 patients whose PDA minimal diameter was > 4 mm. A 4 Fr catheter was used for coil deployment in 136 patients, a 3 Fr in 4, and an 8 Fr in 4 patients who received the GGVOD. A single coil was used in 77 patients and multiple coils (2–6) were used in 66 patients. One hundred forty-six patients had successful closure (142 had immediate complete closure and 4 had residual shunt), 3 patients failed the initial attempt (2 underwent surgical ligation and 1 had a successful second attempt a year later). Of the four patients with residual shunt, three underwent a second procedure with implantation of 1–3 coils resulting in complete closure in all and one patient had spontaneous resolution of the residual shunt. Complications were encountered in nine patients: six had coil migration with successful retrieval in four; two had left pulmonary artery stenosis (2.4 kg and 6.3 kg infants), and one patient had loss of femoral arterial pulse. The median fluoroscopy time was 16 min (2–152 min). One hundred forty-two patients had the procedure as an outpatient, five patients stayed greater than 24 hr, and two of these patients were in hospital for 1 month for noncardiac reasons. At a median follow-up interval of 3.0 years (1 month to 5.1 years), there were no episodes of delayed coil migration, delayed recanalization, thromboembolic episodes, or bacterial endocarditis. Lung perfusion scans performed at a median follow-up interval of 1.6 years in 31 patients who received multiple coils revealed 45% ± 5% blood flow to the left lung. Long-term follow-up of coil closure of PDA indicates that the technique is safe and effective for most pa-tients with PDA up to a diameter of 7 mm. Cathet. Cardiovasc. Intervent. 47:457–461, 1999. © 1999 Wiley-Liss, Inc.  相似文献   

4.
PURPOSE: To describe the radiographic appearance of the Gianturco and the Cook detachable coils and present the clinical results in patients who underwent transcatheter closure of patent ductus arteriosus. MATERIALS AND METHODS: Between January 1994 and June 1997, eighty-two patients underwent closure of patent ductus arteriosus (PDA) using either Gianturco or Cook detachable coils. The chest x-ray and echocardiography of all patients were reviewed and the following parameters were evaluated: 1) the size of the heart (cardiothoracic ratio), 2) the position and the type of the coils in the postero-anterior and the lateral projection, 3) the number of coils used, 4) the existence of residual ductal flow, 5) Doppler velocity in the left pulmonary artery. RESULTS: Complete occlusion was achieved in 94%, and cardio-thoracic ratio regressed from 0.57 to 0.53 (p < 0.01), after a mean follow-up of 1.2 years. The identification of the different coils on the chest radiograph was successful in only 47% of cases, difficulties arising especially, when multiple coils were used. In 55 patients (67%) the coil position was judged to be optimal, in 27 patients (33%) suboptimal. The latter correlates with the presence of residual shunt. Multiple coils correlated more with a left pulmonary artery flow velocity exceeding 1.5 m/s. CONCLUSION: Coil-occlusion of patent ductus arteriosus is effective and leads to reduced cardio-thoracic ratio. Radiographic coil identification is possible but may be difficult if multiple coils are deployed. Suboptimal coil position led more often to residual PDA shunt. Multiple coils are more commonly associated with increased LPA velocities, but hemodynamic significant obstruction to flow is rare.  相似文献   

5.
目的探讨经导管封堵动脉导管未闭(PDA)介入治疗后残余分流的可行性和临床疗效。方法自1997年3月至2001年8月16例PDA介入治疗后残余分流的患者,其中男4例,女12例,平均年龄5.9±2.4岁(2~9岁),平均体重17.7±5.4kg(9~28kg),应用不同介入方法经动脉或静脉途径封堵残余分流,首次介入治疗与再次介入治疗的时间间隔平均为1.5±1.1年(1天~3.5年)。结果残余分流直径平均为2.7±0.9mm(1.2~5.0mm)。15例成功完成残余分流封堵术,1例失败,技术成功率为94%(15/16)。单纯应用Cook可控弹簧圈9例(其中双弹簧圈2例),Rashkind双面伞2例,Sidris纽扣式补片1例,Amplatzer蘑菇伞2例,同时应用Cook可控弹簧圈和Sidris纽扣式补片1例。封堵术后即刻造影,3例仍有少量残余分流,完全闭合率为80%(12/15)。平均手术时间为75.0±22.8min(45~120min),平均X线透视时间为10.4±3.9min(5~20min)。股动脉并发症1例,其余无并发症出现。封堵术后24h复查超声心动图,所有残余分流均完全闭合(100%),在平均2年随访中未出现残余分流再通、封堵器移位和左右肺动脉狭窄。结论经导管封堵PDA介入治疗后残余分流安全、疗效确切、创伤小,可作为外科手术治疗PDA介入治疗后残余分流的一种替代方法。  相似文献   

6.
Objectives. This report evaluates the use of Gianturco coils to close large patent ductus arteriosus (PDAs) (≥3.5 mm) and describes transvenous delivery of 0.052-in. (0.132-cm) Gianturco coils.

Background. Coil closure of PDAs has become increasingly popular. However, the technique has significant limitations when used to close large PDAs. This report evaluates patient characteristics, PDA anatomy, hemodynamic variables, delivery technique and coil geometry to determine predictors of success.

Methods. Between January 1995 and January 1997, 16 of 118 patients undergoing catheterization for PDA closure were found to have large PDAs. Their median age and weight were 14 months (range 3 months to 43 years) and 8.5 kg (range 3.5 to 73), respectively. The mean PDA diameter was 4.3 mm (range 3.5 to 5.9). Closure of PDAs was attempted using transcatheter delivery of 0.038-in. (0.096-cm) and 0.052-in. coils. Differences in clinical, anatomic, hemodynamic and technical variables between successes and failures were compared.

Results. Eleven (69%) of 16 patients had successful closure of their PDA. Failures occurred only in patients <8 months of age with an indexed PDA diameter >7 mm/m and a pulmonary/systemic flow ratio ≥2.8:1. Use of 0.052-in. coils tended to reduce the incidence of embolization and the number of coils needed for closure.

Conclusions. Patients >8 months of age can have successful closure of large PDAs with currently available Gianturco coils. The 0.052-in. Gianturco coils can be used safely to close large PDAs in infants as small as 6 kg. Increased experience and improved coil design may improve closure rates of large PDAs in infants.  相似文献   


7.
We present the short- and intermediate-term results of transcatheter closure of patent ductus arteriosus with Gianturco coils in adolescents and adults. During a 5-year period, 55 patients (44 females, 11 males) with ages ranging from 14 to 72 years (median, 23) underwent attempted transcatheter closure of patent ductus with the Gianturco coils. The diameter of the narrowest segment of the ductus ranged from 0.8 to 7.6 mm (3.9 +/- 1.3 mm). The 55 patients were divided into three groups. Group I consisted of nine patients with a ductal diameter < or = 3 mm, group II consisted of 27 patients with a ductal diameter > 3 mm but < or = 4 mm, and group III consisted of 19 patients with a ductal diameter > 4 mm. Four- to five-loop Gianturco coils were used, which were deployed via retrograde aortic route. Multiple-coil technique was generally applied in group II patients. Balloon occlusion technique in combination with multiple-coil technique was generally used in group III patients. Deployment of coil was successful in 51 patients (93%) but failed in 4. The success rate of coil deployment in group I, II, and III were 100% (9/9), 96% (26/27), and 84% (16/19), respectively. A mean of 1.9 +/- 0.7 coils was deployed per patient. Of the four patients with unsuccessful coil deployment, three underwent surgery and one received implantation with Amplatzer duct occluder. Distal embolization of 21 coils occurred in 10 patients (3 in group II and 7 in group III), from whom 20 coils were retrieved with a gooseneck snare and 1 coil was removed during surgery. The mean diameter of ductus in the 10 patients with distal embolization was significantly larger than that in those without (5.2 +/- 1.4 vs. 3.7 +/- 1.1 mm; P < 0.01). Among the 51 patients with successful coil deployment, immediate complete closure was achieved in 20 (39%), while trivial to mild leak was present in 31 (61%). No significant complications were encountered. After a follow-up period ranging from 5 to 42 months, four patients had a small residual shunt and three underwent a second intervention with complete occlusion. None had left pulmonary artery stenosis documented with Doppler echocardiography. Transcatheter closure of ductus with the Gianturco coils is safe and feasible in the majority of adolescents and adults. Taking high embolization rate in patients with a ductus diameter > 4 mm into consideration, controlled-release coils, Buttoned device, or Amplatzer duct occluder can be a better choice.  相似文献   

8.
We describe a novel method that allows bioptome-assisted delivery of multiple Gianturco coils simultaneously for occlusion of the large patent ductus arteriosus (PDA). Two or more coils were intertwined at one end and held by a bioptome (5.2 Fr) and pulled into a short introducer. The coils were then deployed in the PDA via a long sheath (7-11 Fr) previously placed across the duct via the femoral vein. Twelve patients (6 months to 64 years; median, 10.5 years) with large PDAs (4.7 +/- 1.3 mm; range, 3.1-8.4 mm; PA mean pressure, 40 +/- 17 mm Hg; pulse pressure 63 +/- 18 mm Hg) underwent bioptome-assisted occlusion with multiple coils at our institutions. The procedure was uneventful in nine patients (fluoroscopy time, 6-23 min) and prolonged in three patients (fluoroscopy time, 26, 72, and 120 min) because of dislodgment of the coil mass and embolization of an additional coil. Successful coil deployment was feasible in all patients. Three patients required repeat coil deployment for flow elimination (hemolysis occurred in two). Flow elimination was demonstrated on the last follow-up evaluation in all except two patients. One infant has developed significant left pulmonary artery stenosis. Bioptome-assisted PDA occlusion using multiple coils delivered simultaneously may be a promising alternative to devices for transcatheter closure of large PDAs. Cathet Cardiovasc Intervent 2001;54:95-100.  相似文献   

9.
Precise delineation of the size and shape of the ductus arteriosus may help in catheter closure. The use of Intravascular Ultra Sound (IVUS) to study the diameter of patent ductus arteriosus (PDA) has not been reported. We prospectively evaluated the use of IVUS and compared it to angiography in determining the size and shape of PDA and to assess the degree of coil protrusion into the descending aorta and the clinical relevance after coil closure. Twenty-six patients (17 female, 9 male) underwent transcatheter closure of PDA using single or multiple Gianturco coils. The median age of the patients was 1.7 yr (range, 2 monthsD34 yr) and the median weight was 10.9 kg (range 4.2D80 kg). A good quality IVUS image was obtained in all patients using 3.8 Fr, 30 MHz catheters. The median PDA diameter measured by angiography was 2.8 mm (range 1.6D5.7 mm) and by IVUS was 3.2 mm (range 1.7D5.7). There was excellent agreement between IVUS and angiography (D IVUS = 0.25+0.97*D angio, r = 0.90, (D: diameter in mm). After closure, coils could be seen protruding into the aorta with a median percent coil protrusion of 17.3% (range 0.0D47%). Only one patient had the coil protruding into more than 1/2 the aorta. This coil was retrieved and another coil was placed successfully. On follow-up at a median interval of 2.4 yr. (range 1.1D3.2 yr), there has been no clinical evidence for thromboembolic events. We conclude that IVUS use to assess the size of PDA is accurate. On mid-term follow-up, coil protrusion into the aorta seems to be benign. Further follow-up is needed.  相似文献   

10.
Objectives. The aim of this study was to assess the immediate and short-term results of anterograde catheter closure of a moderate- to large-sized patent ductus arteriosus (PDA) using the new self-expandable, respositionable Amplatzer duct occluder (ADO) device.Background. Transcatheter closure of a PDA using devices or coils is technically challenging and may be accompanied by a 38% incidence of residual shunts.Methods. Twenty-four patients (6 male, 18 female) underwent attempted transcatheter closure of a PDA using the ADO at a median age of 3.8 years (range 0.4 to 48) and a median weight of 15.5 kg (range 6 to 70). The mean PDA diameter at its narrowest segment was 3.7 ± 1.5 mm. A 6F long sheath was used for delivery of the ADO. Follow-up evaluation was performed with color flow mapping of the main pulmonary artery within 24 h and at 1 and 3 months after closure.Results. Twenty three of the 24 patients had successful device placement. Angiography showed that 7 patients had complete immediate closure, 14 had a trace shunt (foaming through the device with no jet), and 2 had a small residual shunt (with a jet). Within 24 h, color Doppler revealed complete closure in all patients. The unsuccessful attempt was during an initial trial with a prototype that has been modified. The median fluoroscopy time was 13.5 min (range 6.3 to 47). All patients were discharged home the next day. There were no complications. Of the 23 patients, 21 completed the 1-month follow-up, all (95% confidence interval [CI] 86% to 100%) with complete closure, and 18 of 23 patients completed the 3-month follow-up, also all (95% CI 83% to 100%) with complete closure.Conclusions. Anterograde transcatheter closure using the new ADO is an effective therapy for patients with a PDA diameter up to 6 mm. Further clinical trials are underway.  相似文献   

11.
Background: The Rashkind Umbrella device has proven effective in closing small to moderate size patent ductus arteriosus. A comparable early occlusion rate was also seen in PDA occlusion using Gianturco coils. This study addresses the long-term outcome of both techniques in a single centre. Methods: Review was undertaken of 522 patients with PDA who underwent transcatheter occlusion before January 1997; 244 patients (mean: age 8.0±6.7 years, weight 21.8±12.9 kg, PDA size 3.2±1.0 mm) were intended to receive the Rashkind Umbrella device and the remaining 278 patients (mean: age 6.4±5.6 years, weight 18.6±11.2 kg, PDA size 2.5±1.0 mm) would receive Gianturco coils. Deployment failure occurred in 8 patients (3%) and 6 (2%) during the initial learning curve of the Rashkind Umbrella and Gianturco coil, respectively. In the Rashkind Umbrella group, haemolysis occurred in 6, device embolisation in 3, and 1 patient died from anaesthetic sequelae. Peripheral pulmonary embolisation of coils occurred in 7 patients and all were successfully retrieved. Results: Results were analysed from 228 and 258 patients who had successful Rashkind Umbrella device and Gianturco coil deployment respectively. All had completed at least 1 year follow-up. They were evaluated clinically for residual ductal murmur and echocardiographically for a residual ductal shunt and presence of pulmonary artery or aortic obstruction. The Rashkind Umbrella group had significantly higher residual shunt compared to the Gianturco coil group at various stages of follow-up (p<0.05), 40% v 22% at 24 hours, 29% v 7% at 3 months, 25% v 4% at 6 months and 22% v 3% at 1 year. In 57 patients, a reocclusion procedure during the study period was undertaken to effect immediate complete occlusion. Mild left pulmonary artery stenosis (velocity<2 m/s) was noted in 6 patients who had multiple coils and one who had a 17 mm Rashkind Umbrella device. Conclusions: Transcatheter occlusion of PDA using the Gianturco coil is safer and more effective than the Rashkind Umbrella device. It has become the first choice for treating small to moderate size native PDA at our institution.  相似文献   

12.
Recent reports suggest reopening of the patent ductus arteriosus (PDA) after complete occlusion with three-loop Gianturco coils. We hypothesize that five-loop coils may produce a larger thrombus than three-loop coils, which will result in no or less probability of recanalization of PDA during follow-up. This study is designed to test this hypothesis. Follow-up echocardiographic and Doppler data of 30 patients who underwent five-loop coil occlusion of small to medium-sized PDA during a 33-month period ending December 1998 were examined. Thirty patients had no residual shunt on echo Doppler study on the day following the procedure and were followed for 6 to 30 months (median, 12) after coil implantation. At the last follow-up study, none of the patients had a residual shunt and left atrial size decreased. Careful pulsed, continuous wave, and color Doppler interrogation of left/main pulmonary artery junction and proximal descending aorta did not reveal any evidence for obstruction. The follow-up data suggest that complete occlusion of small- to medium-sized PDAs is feasible with five-loop coils without evidence for recanalization at a mean follow-up of 12 months. Much longer (2 to 5 years) follow-up data may be necessary to confirm these observations. We speculate that a greater degree of thrombosis is produced within the ductus by the five-loop coils, which in turn may be responsible for lack of shunt recurrence. We recommend use of five-loop instead of three-loop coils for transcatheter occlusion of small- to medium-sized PDAs.  相似文献   

13.
OBJECTIVES: We evaluated the occlusion rate and safety of Cook detachable coils versus Gianturco coils in transcatheter closure of patent ductus arteriosus (PDA). BACKGROUND: The Cook detachable coil recently was introduced in an attempt to improve the safety of transcatheter closure of PDA. METHODS: Between January 1994 and September 1998, 272 patients underwent transcatheter PDA closure. Cook detachable coils were used in 137 patients, with a mean age of 43.9 months and weight of 13.8 kg. In 135 patients, Gianturco coils were used, with a mean age of 56.8 months and weight of 17.8 kg. The mean narrowest diameter of the PDA in the Cook detachable coil group was 2.85 mm versus 2.32 mm for the Gianturco coil group. RESULTS: The Cook detachable coil group was younger and weighed less than the Gianturco group (P < 0.05 and 0.02, respectively). Their narrowest PDA diameter was larger (P < 0.01). Embolization rate was significantly lower in the Cook coil group (9[6.5%] of 137 vs 22 (16.3%) of 135; P = < 0.013). The mean follow-up for the Cook coil group was significantly shorter (0.55 years) than for the Gianturco coil group (1.18 years; P < 0.001). On an intention-to-treat basis, complete occlusion by echocardiography was achieved in 99 (72.3%) of 137 patients in the Cook detachable coil group, which was significantly less than the Gianturco coil group (114 [84.4%] of 135; P = 0.008). CONCLUSION: Cook detachable coils for transcatheter closures of the PDA are safer than Gianturco coils. Hence, children with large ductal can be treated earlier in life. Short-term complete occlusion rate was lower in the Cook detachable coil group. This rate can be explained by a shorter follow-up time, larger ductal diameter, and the different materials used for the detachable coils.  相似文献   

14.
Background : Over the past three decades, transcatheter occlusion of patent ductus arteriosus (PDA) has evolved to be the procedure of choice. Gianturco and Flipper coils are the most commonly used coils in the United States for closure of small and moderate size PDAs. For larger PDAs, interventionalists in the United States commonly use the Amplatzer Duct Occluder (ADO) and those in Europe use the ADO or the Nit‐Occlud Coils (NOC). A comparison between Gianturco coils, Flipper coils, ADO, and NOC has never been made. Objective : To compare the success and complication rate associated with the four different devices used for transcatheter closure of PDA. Success was defined as complete closure of PDA with absence of a residual shunt (R.S.) at six months follow‐up. Methods : Two institutions collaborated in combining their data to evaluate the results of transcatheter closure of PDA. Results : Totally, 546 patients underwent successful PDA occlusion at both institutions. Gianturco and Flipper coils were used in 120 (22%) and 119 (22%) patients respectively. A total of 152 (28%) patients received ADO and 155 (28%) patients received NOC. Immediate R.S. were noted in 226 (41.4%) patients in the entire study group with the NOC group having the highest percentage of R.S. (80/155, 51.6%, P = 0.004). Of the 484 patients with follow‐up echocardiograms at 6 months, 35 (7.2%) patients had persistent R.S. The NOC (3/143, 2.1%) and ADO (5/150, 3.3%) groups had the least R.S. at six months follow‐up. Conclusion : Per our definition of success, the Nit‐Occlud coils and the Amplatzer duct‐occluder devices had significantly higher success rate for PDA occlusion versus the coils. © 2010 Wiley‐Liss, Inc.  相似文献   

15.
Background and hypothesis: Although results of surgical ligation of the patent ductus arteriosus (PDA) in the pediatric age group are excellent, surgical management of the adult with a PDA may be more problematic. The PDA that presents in adulthood may be calcified and friable, rendering simple ligation via a thoracotomy difficult, inadequate, and hazardous. Patch closure of the ductus arteriosus from either the aortic or pulmonary artery orifice using cardiopulmonary bypass or transient aortic cross-clamping is necessary but increases surgical risks. Furthermore, older patients with diseases unrelated to their PDA and patients with Down's syndrome may have higher risks with intubation, general anesthesia, and surgery. Early results of percutaneous transcatheter occlusion of the PDA with Gianturco coils performed under sedation and local anesthesia are promising. Methods: Six adults with mean age of 39.1 years (range 23.1–62.0 years) were found to have an isolated PDA with mean minimum diameter of 2.7 mm (range 1.0–5.0 mm) at cardiac catheterization. All underwent percutaneous transcatheter occulsion of the PDA using Gianturco coils. Results: Coil implantation was successful in all patients. There were no complications and all were discharged home within 24 hours. Complete ductal occlusion was seen immediately in 4 of 6 patients (67%) while 2 of 6 (33%) had small residual leaks. However, complete occlusion was achieved in all patients by 6 months following the procedure. Conclusion: Transcatheter occlusion of the PDA using coils is safe and efficacious in adults.  相似文献   

16.
F Shamsham  T Kwan  A M Safi  L T Clark 《Angiology》1999,50(6):519-522
Patent ductus arteriosus (PDA) is a form of congenital heart disease uncommonly diagnosed in adult patients. Transcatheter closure of PDA has been widely used in children. However, the experience is limited in adults especially with use of Gianturco coils. The authors describe a case of successful transcatheter closure of a PDA, incidentally diagnosed in a 41-year-old woman, by successively deploying two coils by a transarterial approach. No residual shunting was seen angiographically after the procedure. A literature review of similar procedures in adult patients is discussed.  相似文献   

17.
We describe our early experience with a new technique involving temporary balloon occlusion for transcathether closure of patent ductus arteriosus (PDA) using single or multiple Gianturco coils. Coil occlusion was attempted in 21 patients of median age 3 (range 1–11) years, and angiographic PDA diameter 3.0 mm ± 0.87 mm. The inflated balloon of a pulmonary wedge pressure catheter over a transductal wire was used to mechanically hold the first extruded loop of the coil at the pulmonary end of the duct. If a residual shunt persisted after the delivery of the first coil, additional coils were delivered with or without the balloon support. One to nine coils (median 2) of different sizes varying between 3–12 mm diameter and 4–15 cm length were used. Immediate angiographic occlusion rate was 47.6%. However, color Doppler (CD) at 24 hours and at 6 weeks revealed complete closure in 66.6% and 80.9%, respectively. Blood transfusion was required in 2 (9.5%) patients. Three out of 56 coils (5.4%) embolized during deployment. The use of balloon occlusion is effective and safe in the treatment of ducti up to 4.7 mm. Residual shunts tend to occlude with time. Cathet. Cardiovasc. Diagn. 41:62–70, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

18.
Objectives: The present study evaluates two transcatheter closure strategies utilized at a single center and makes recommendations for device selection when occluding the patent ductus arteriosus. Background: A variety of devices are available for transcatheter closure of the patent ductus arteriosus (PDA) but no guidelines exist to guide operator device choice. Methods: A total of 132 patients underwent attempted transcatheter PDA closure utilizing one of two consecutive closure strategies between January 2000 and June 2005. Strategy A (n = 64; January 2000–May 2003) utilized Gianturco coils only. Strategy B (n = 68; June 2003–June 2005) utilized a single Gianturco coil for the PDA with a minimal diameter ≤1 mm (n = 28) or an Amplatzer Duct Occluder (ADO) if the PDA diameter exceeded 1 mm (n = 40). Success was defined as complete occlusion on a follow up echocardiogram. Results: 58 of 64 (90.6%) patients treated utilizing strategy A had successful coil implantation. 68 of 68 (100%) patients treated utilizing strategy B had successful coil/device implantation. At follow up echocardiography, 32 of 44 (72.7%) strategy A patients had complete ductal closure, as compared with 57 of 58 (98.3%) strategy B patients (P < 0.0001). Stepwise logistic regression analysis identified closure strategy as the most powerful predictor of procedural success (OR = 85.9; CI 5.6–9.99). Conclusions: A transcatheter PDA closure strategy consisting of a single Gianturco coil for PDA ≤ 1 mm or an ADO for larger sized PDA (strategy B) achieves superior outcomes compared to the use of coils alone. © 2008 Wiley‐Liss, Inc.  相似文献   

19.
Objectives . We report the use of non‐ferromagnetic embolization coils for transcatheter PDA closure. Background . Transcatheter patent ductus arteriosus (PDA) closure has been performed for 40 years. A number of devices have been used with varying degrees of success. Gianturco embolization coils have been used frequently since 1992 with excellent results. These coils are a stainless steel alloy, and create an artifact when subsequent MRI imaging is performed. Methods . Eight patients underwent right and left heart catheterization and transcatheter PDA closure. Angiography displayed a PDA with left to right shunting. The minimum PDA diameter was measured. An Inconel MReye coil was implanted using standard retrograde technique. A postimplant angiogram was performed. Evaluations were performed the following morning and after 2 months. Results . The median age was 5.5 years, median weight was 24 kg. The PDA minimum diameter was 1.7 mm (range 1.4–2.4 mm), with a median Qp:Qs=1.33:1. In all patients, the PDA was completely immediately closed using one Inconel coil. Two patients also had a small aorto‐pulmonary collateral vessel that was occluded using a separate Inconel coil. All patients had follow‐up evaluation the following day; the PDA remained completely occluded and there was no obstruction of the pulmonary artery branches or descending aorta. Seven patients had subsequent follow‐up and echocardiograms; the PDA remained completely occluded. There were no complications. Conclusion . The Inconel MReye coil is safe and effective for coil occlusion of small PDA and aorto‐pulmonary vessels. Additional studies are needed to define the maximum vessel diameter for Inconel coil occlusion. © 2008 Wiley‐Liss, Inc.  相似文献   

20.
Between May 1997 and June 2000, 69 patients, ages 0.1 to 34 years, underwent attempted anterograde transcatheter closure of a patent ductus arteriosus (PDA) using the Amplatzer Duct Occluder (ADO). The ADO is a cone-shaped, self-centering, and repositionable occluder made of nitinol wire mesh. A 5Fr to 7Fr sheath was used for the delivery of the device. The mean PDA diameter (at the pulmonary end) was 4.6 +/- 1.9 mm (range 1 mm-8.5 mm). Sixty-seven of the 69 patients had successful device placement. The mean ADO smallest diameter was 6.9 +/- 1.8 mm (range 4 mm-12 mm). Complete angiographic closure occurred in 62 (92.5%) of 67 patients (95% confidence interval, 88.22%-98.77%). In five patients, there was a trivial residual shunt immediately after the procedure. At 24 hours, color Doppler flow imaging revealed complete closure in all 67 (100%) patients. The unsuccessful attempts occurred in two patients with a small, 1-mm diameter native PDA and residual PDA after surgical occlusion. Fluoroscopy time was 7.6 +/- 1.8 minutes (4 min-18 min). No complications were observed. At a median follow-up of 1.5 years (range 0.25 to 3.2 years), all patients had complete closure without complications. We conclude that transcatheter closure using the ADO is a highly effective and safe treatment for most patients with PDA.  相似文献   