首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
J R Walters  L M Banks  G P Butcher    C R Fowler 《Gut》1995,37(2):220-224
Patients with coeliac disease may present with calcium malabsorption but it is unclear whether this results in longterm impairment of bone mineralisation. Dual energy x ray absorptiometry (DXA) was used to study bone mineral density in 34 asymptomatic coeliac disease patients, treated with a gluten free diet for at least two years, and also in 10 newly diagnosed or untreated patients. As expected, untreated patients had low bone mineral density in all regions. In the 29 treated female coeliac disease patients, overall mean values for age adjusted bone mineral density expressed as Z scores were normal although there were many patients with low values, particularly of the lumbar spine and total body. Scores in the postmenopausal patients were significantly worse than in the premenopausal patients and low mean Z scores were found in the five treated male patients. The subjects who had reduced bone mineral density could not be predicted clinically but, despite being asymptomatic, were more likely to have subtotal or partial villous atrophy on small intestinal biopsy (p < 0.0275). In conclusion, although many treated coeliac disease patients have normal bone mineral density, suboptimally treated and newly diagnosed or untreated patients have osteopenia. To reduce the risk of osteoporotic fractures, it is recommended that bone mineral density be measured in all treated coeliac disease patients and those with osteopenia have a repeat intestinal biopsy to assess disease activity.  相似文献   

2.
Hand bone densitometry is more sensitive than standard radiology in the measurement of disease-related bone damage in early arthritis. Most studies employing dual energy x-ray absorptiometry (DXA) have evaluated the whole hand. The aim of this study was to evaluate a method that quantified bone density in regions of interest that were confined to the juxta-articular areas of metacarpo-phalangeal (MCP) and proximal interphalangeal (PIP) joints. Patients with inflammatory arthritis affecting the hands were selected for study. Postero-anterior (PA) scans of selected juxta-articular sub-regions were acquired using a Hologic 4500 Elite bone densitometer and forearm software. Each hand was scanned three times in immediate succession with repositioning between scans. The six selected sub-regions included the periarticular regions of the second, third, and fourth MCP and PIP joints. Sub-regions of different dimensions (4 and 5 mm proximal and distal to the joint space) were assessed at each joint. Coefficients of variation (CV) were calculated for bone mineral density (BMD) and bone mineral content (BMC) of each selected sub-region. Eighty four individual hand joints in seven patients were evaluated three times. Precision values ranged between 0.89% and 2.37% for BMD and between 1.38 and 3.26 for BMC measurements. BMD measurements of MCP joints were more precise than PIP joints. BMD measurements of 10-mm sub-regions were more precise than 8-mm sub-regions. The precision value for the net average BMD measurement of the six sub-regions evaluated was 0.78% for 8-mm sub-regions and 0.73% for 10-mm sub-regions. Net average BMC measurements had CV values of 1.11% and 1.08%, respectively. DXA can be used to reliably measure periarticular BMD and BMC of small joints in the hands in patients with early inflammatory arthritis. Precision values for quantifying juxta-articular bone approximated BMD measurements of the spine.  相似文献   

3.
4.
Aims: The earliest radiological change in rheumatoid arthritis (RA) is periarticular osteopenia, which occurs prior to the appearance of erosions and clinically apparent deformities. The aim of the study was to measure periarticular bone mineral density (BMD) in the hands of patients with early RA, using dual energy X‐ray absorptiomentry (DEXA) and to correlate this with markers of disease activity and radiological progression. Methods: The study population (n = 50) of patients with RA of < 3 years duration underwent measurement of BMD of the non‐dominant hand, femoral neck and lumbar spine and clinical assessment at baseline, 6 and 12 months. Hand radiographs were performed at baseline and 12 months. Thirty age‐ and sex‐matched controls also underwent measurement of BMD of the non‐dominant hand, femoral neck and lumbar spine. Results: Hand BMD correlated strongly with sex, height, weight and lumbar and femoral neck BMD in both RA subjects and controls. Baseline hand BMD in RA subjects correlated with baseline serum C‐reactive protein (r = ?0.36, P = 0.01) and 12‐month radiographic score (r = 0.36, P = 0.02). There were small non‐significant decreases in hand, femoral neck and lumbar spine BMD over the 12‐month period. Conclusion: Hand BMD measurement using DEXA is a reproducible, well‐tolerated procedure that warrants further investigation as a component of routine assessment in early RA.  相似文献   

5.
Dual energy x ray absorptiometry and a wide range of blood and urine tests were used to assess the propensity of patients with systemic lupus erythematosus to develop an impairment of bone mineral density. Surprisingly, in this preliminary study no significant differences in bone mineral density were found when patients taking 10 mg or more of prednisolone for six months or longer were compared with those who had never taken prednisolone.  相似文献   

6.
OBJECTIVE We assessed the changes of bone mass in patients with hyperthyroidism by measuring bone mineral density using a new method, dual energy X-ray absorptiometry. DESIGN The values of bone mineral density in patients with hyperthyroidism were compared with data obtained from the controls, and we assessed the correlation analysis between bone mineral density and several metabolic parameters. PATIENTS We studied 52 Japanese patients with hyperthyroidism (20 males, 32 females). Healthy normal subjects served to establish the mean bone mineral density In the healthy Japanese population (Shiraki et al. 1991). MEASUREMENT Bone mineral density was assessed by the measurement of lumbar vertebrae and femur by dual energy X-ray absorptiometry. The bone mineral density of vertebrae for each patient was calculated as the percentage of the mean value (% bone mineral density) obtained from an age and sex-matched control group. Blood was drawn to measure the levels of serum calcium, phosphorus, creatinine, alkaline phosphatase, free T3, free T4, TSH, TSH receptor antibody, parathyroid hormone, and serum osteocalcin. RESULTS The percentage bone mineral density of vertebrae in patients was 92.6 as compared with that of normal controls, and was inversely correlated with serum TSH receptor antibody, osteocalcin, and alkaline phosphatase. CONCLUSIONS These findings suggest that bone mineral density is decreased in patients with hyperthyroidism and that TSH receptor antibody, osteocalcin, and alkaline phosphatase are sensitive markers of bone metabolism alterations in hyperthyroidism.  相似文献   

7.
8.
于1995年9月体检人群中,随机采用Hologic2000型双能X线骨密度仪(DEXA)测量186例骨密度。结果提示年龄每增5岁,髋部、Ward区及腰椎1~4三处之骨密度递减(P<0.05)。≥60岁组之骨峰骨量亦随增龄而降低(P<0.01)。骨峰值在≥60岁组下降2个标准差以上者占61.3%。女性除Ward区骨量,均低于男性(P<0.01)。  相似文献   

9.

Objective

To determine the bone mineral density (BMD) status of our juvenile dermatomyositis (DM) population and to compare the frequency of osteopenia in patients with active disease requiring corticosteroids with that in patients with inactive disease who are not receiving corticosteroids.

Methods

Medical charts of all children diagnosed as having juvenile DM at our institution between 1989 and 1999 were reviewed for demographic and clinical data, including disease activity and duration of corticosteroid therapy. BMD measurements of the lumbar spine (L1–L4) were performed using dual x‐ray absorptiometry (DXA). Z scores were calculated from the BMD data for comparison with published normative data.

Results

A total of 15 patients were assessed: 10 with active disease, and 5 with inactive disease who had not taken corticosteroids for an average of 6.0 years (range 3.4–8.1 years). Baseline BMD measurements demonstrated osteopenia or frank osteoporosis in the majority of patients, including 6 of the 10 patients with active disease and 4 of the 5 patients whose disease was in remission. Fourteen patients had serial BMD measurements. Persistent or worsening osteopenia was documented in all patients who had ongoing active disease, except for 3 patients who had been treated with bisphosphonates because of vertebral compression fractures.

Conclusion

Osteopenia is common in patients with juvenile DM, and it usually worsens with ongoing disease. It can persist for many years after the disease enters remission. Bisphosphonates appeared to beneficially affect bone mineralization in our patients. Treatment to prevent the long‐term complications of osteoporosis in patients with juvenile DM should be considered and requires further study.
  相似文献   

10.
11.
OBJECTIVE: To examine relationships of bone quality as assessed by quantitative ultrasound (QUS) and bone mineral density (BMD, g/cm(2)) with quadriceps strength (QS) in women with rheumatoid arthritis (RA). METHODS: Sixty seven women with RA according to the 1987 American College of Rheumatology (ACR) criteria were examined. Mean (SD) age was 62 (13) years, mean disease duration 15 years. Most were or had been receiving glucocorticoid treatment. Calcaneal bone quality expressed as speed of sound (SOS, m/s), broadband ultrasound attenuation (BUA, dB/MHz), and stiffness was measured by QUS. BMD of the femoral neck, spine, and distal forearm was measured by dual energy x ray absorptiometry (DXA). Maximal voluntary isokinetic quadriceps strength (Nm) was assessed by isokinetic dynamometry. Pain was recorded on a visual analogue scale (VAS), disability was scored by the Stanford Health Assessment Questionnaire (HAQ), and the degree of physical impairment was expressed by the Steinbrocker index (SI). RESULTS: In multiple regression analyses, QS predicted SOS, BUA, and stiffness (r(partial) ranging from 0.36 to 0.45, p<0.005) and femoral neck BMD (r(partial)=0.30, p<0.05) independently of age, height, weight, disease duration, HAQ, VAS, SI, and cumulative steroid dose. BMD of the spine and distal forearm was not associated with QS. After adjustment for covariates, women with subnormal BMD of the femoral neck (T score <-1), had a 20% lower QS than those with normal BMD (p<0.0001). CONCLUSIONS: Calcaneal bone quality and femoral neck BMD were associated with QS in women with RA. This finding indicates that physical activity including muscle strengthening exercises may play a part in the prevention of bone loss in these patients.  相似文献   

12.
OBJECTIVE: To consider whether bone mineral density (BMD) measurements can predict traumatic fractures occurring in perimenopausal women. METHODS: One thousand perimenopausal women called up for screening underwent both dual energy x ray absorptiometry (DXA) of the spine and hip, and broadband ultrasound attenuation (BUA) of the heel. Two years later, they were sent a questionnaire to discover those who had since had a fracture, and compare them with those who had not. RESULTS: About 2% of the women had sustained a fracture in the two years since attendance for screening. Fractures in this age group can be predicted weakly, but significantly, by bone mass measurements using DXA and BUA (odds ratios from 1.4 to 2.1). The lumbar spine appeared to be one of the best predictive sites (odds ratio for 1 SD reduction in BMD 2.1 (95% confidence interval 1.2 to 3.8)), but no significant differences were found between the areas under the curve in receiver operator characteristic (ROC) analysis. CONCLUSION: In this preliminary study it appeared that bone mass measurements are predictive of perimenopausal traumatic fractures in addition to postmenopausal fractures related to osteoporosis. DXA of the lumbar spine did not perform significantly better than BUA. The number of fractures occurring was low, however, and further long term follow up is required to confirm the finding.  相似文献   

13.
In order to evaluate the degree of accuracy of measurement of total body bone mineral content (TBBMC) by dual photon absorptiometry (DPA), the TBBMC in four healthy male volunteers were measured serially for 3 to 12 months. In three to six determinations of TBBMC in various stage of radiation source (153-Gd), the coefficients of variation in four subjects were 1.59, 0.74, 1.25 and 1.27%. Thus, the mean CV was 1.22 +/- 0.35% (mean +/- SD). This indicates that the measurement of TBBMC using DPA is an accurate tool for long-term follow up of bone mineral content and up to 1.6% change of TBBMC might be considered to be a significant change in TBBMC. No apparent drift of TBBMC associated with source decay was noticed in the present study. Subsequently, fifteen females with osteoporosis were studied to evaluate the efficacy of certain therapeutic modes. The patients were divided into two groups. Group 1 (n = 10) given 10 to 40 U of elcatonin (eel calcitonin derivative) intramuscularly every week for 3 to 6 months. Group 2 (n = 5) were treated with 0.5 mu/day of oral 1-alpha-OHD3 for 3 to 6 months. The TBBMC of these fifteen patients were followed by DPA (Lunar DP-4). Seven patients out of ten treated with elcatonin (70%) showed significant (up to 1.6% change in TBBMC compared with baseline) increase in TBBMC after 3 to 6 months treatment. The mean percentage change in TBBMC in group 1 was 101.9 +/- 2.7% (mean +/- SD) when the initial TBBMC was taken as 100%.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

14.
The bone mineral density (BMD) of the lumbar spine (L1-L4) was measured by dual energy x-ray absorptiometry (Hologic QDR 1000) in 135 healthy caucasian children, aged 1-15 yr, and values were correlated with age, height, weight, body surface, bone age, pubertal status, calcium intake, vitamin D supplementation, and serum bone gla protein. BMD increased with age in children of both sexes (r = 0.88; P less than 0.001) from 0.446 +/- 0.048 g/cm2 at 1 yr to 0.625 +/- 0.068 g/cm2 at 10 yr and 0.891 +/- 0.123 g/cm2 at 15 yr of age. The increase was steeper at the time of puberty, reaching values above 0.80 g/cm2 after puberty was achieved. There were no significant differences between boys and girls, except at the age of 12 yr when BMD was higher in girls than in boys (P = 0.007), probably because of the earlier onset of puberty in females. BMD was also highly correlated with height, weight, body surface, and bone age. BMD was not correlated with calcium intake when age was held constant, nor with vitamin D supplementation. Serum bone gla protein showed a steady increase during childhood, with peak values at 11-12 yr of age, and was weakly but significantly correlated with BMD (r = 0.27; P = 0.007). Because of low irradiation exposure, rapid scanning, and high precision, dual energy x-ray absorptiometry is a noninvasive method which is well adapted to the child. It should be helpful in the investigation and follow-up of children with diseases impairing bone metabolism.  相似文献   

15.
目的 探讨定量CT(QCT)髋关节骨密度(BMD)测量重复性及与双能X线骨密度测定仪(DXA)测量的一致性.方法 随机抽取28名(男10例,女18例)老年受试者(男性>60岁,女性>50岁),并分别采用QCT与DXA测量髋关节骨密度.收集左侧髋关节QCT扫描CT原始数据,分别由3名操作者各测量1次,其中1名操作者在不同时间重复测量3次,用于评价QCT髋关节骨密度结果的重复性.比较QCT和DXA测量左侧髋关节骨密度结果.结果 3名不同操作者或同一操作者不同时间采用QCT测量28名受试者左侧髋关节的骨密度值之间具有很好的相关性(ICC:0.93~0.98,P<0.01),全髋骨密度值之间差异无统计学意义.DXA与QCT测量的股骨颈和全髋骨密度结果之间具有显著相关性(r=0.88,0.89,P<0.01),DXA测量的骨密度值较QCT相对应骨密度值大10.5%和9.7%(t=7.53,9.68,P<0.01).上述骨密度值系统误差可被校正.结论采用QCT测量髋关节BMD具有较好的重复性,其BMD值与DXA所测BMD结果具有相关性.QCT髋关节(CTXA)骨密度测量可用于骨质疏松症的诊断和疗效随访,具有临床应用前景.  相似文献   

16.
Direct measurement of abdominal fat by dual photon absorptiometry   总被引:1,自引:0,他引:1  
We have assessed photon absorptiometry as a new technique for direct measurement of the abdominal fat percentage (AF%). The accuracy of the method was assessed in vitro with phantoms consisting of ox muscle, lard, and a mixture of both. The results showed good linearity (r = 0.999). The in vitro reproducibility and the in vivo reproducibility were s.d. = 2.0 and s.d. = 2.8 (AF%), respectively. The AF% was measured in 148 healthy post-menopausal women and found to correlate with other measurements of fatness, such as total body fat per cent (r = 0.82, P less than 0.001), body mass index (r = 0.79, P less than 0.001) and the ratio of waist-to-hip circumference (r = 0.59, P less than 0.001). The waist-to-hip ratio, an important predictor of cardiovascular disease, was more tightly correlated with AF% than with body mass index. We conclude that this method may be a useful new research tool for direct measurements of abdominal fat, a possible cardiovascular risk factor.  相似文献   

17.
In this paper, the assessment of radiographic vertebral fracture (prevalent fracture and incident fracture) in the diagnosis of osteoporosis and the therapeutical assessment by bone mineral density measurements are reviewed.  相似文献   

18.
19.
BACKGROUND: Bone mineral density (BMD) measurements are frequently performed repeatedly for each patient. Subsequent BMD measurements allow reproducibility to be assessed. OBJECTIVE: To examine the reproducibility of BMD by dual energy x ray absorptiometry (DXA) and to investigate the practical value of different measures of reproducibility in a group of postmenopausal women. METHODS: Ninety five women, mean age 59.9 years, underwent two subsequent BMD measurements of spine and hip. Reproducibility was expressed as smallest detectable difference (SDD), coefficient of variation (CV), and intraclass correlation coefficient (ICC). Sources of variation were investigated by multilevel analysis. RESULTS: The median interval between measurements was 0 days (range 0-45). The mean difference (SD) between the measurements (g/cm(2)) was -0.001 (0.02) and -0.0004 (0.02) at L1-4 and the total hip, respectively. At L1-4 and the total hip, SDD (g/cm(2)) was +/-0.05 and +/-0.04 and CV (%) was 1.92 and 1.59, respectively. The ICC at spine and hip was 0.99. CONCLUSIONS: Reproducibility in the postmenopausal women studied was good. In a repeated DXA scan a BMD change exceeding 2 radical 2CV (%), the least significant change (LSC), or the SDD should be regarded as significant. Use of the SDD is preferable to use of the CV and LSC (%) because of its independence from BMD and its expression in absolute units. Expressed as SDD, a BMD change of at least +/-0.05 g/cm(2) at L1-4 and +/-0.04 g/cm(2) at the total hip should be considered significant.  相似文献   

20.
Hu  Nan  Zhang  Jing  Wang  Jing  Wang  Pei  Wang  Jing  Qiang  Yongqian  Li  Zicheng  Wu  Tianming  Wang  Xing  Wang  Yahong  Li  Jiao  Liu  Xiaoping  Zhang  Jirong  Feng  Xiuyuan  Ju  Bomiao  Hao  Zhiming  Pu  Dan  Lu  Xiaohong  Wang  Qiang  He  Lan 《Clinical rheumatology》2022,41(3):819-829
Clinical Rheumatology - Biomarkers of bone and cartilage metabolism were proposed as early diagnosis indicators for knee osteoarthritis (OA), however, which were influenced by disease stage, age,...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏