首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
BACKGROUND: Transbronchial needle aspiration (TBNA) performed with a 19-gauge needle provides both cytologic and histologic specimens. However, the diagnostic yield for malignancy gained by histologic examination is unclear. Moreover, this kind of needle is often reserved only for selected cases, in part due to fear for complications. The primary aim of this study was to investigate the diagnostic contribution for malignancy added by histologic to the cytologic specimen examination. The secondary aim was to evaluate the safety of using a 19-gauge needle routinely in all patients. METHODS: Consecutive patients presenting with mediastinal and/or hilar lymph node enlargement of > or = 1 cm, in whom suspicion for malignancy was raised, underwent TBNA with a 19-gauge needle. Patients with negative aspirate test results underwent surgical investigation. RESULTS: Among 77 patients who were examined, 66 had malignant intrathoracic lymphadenopathy. TBNA proved malignancy in 58 patients, whereas it missed the diagnosis in 8 patients (sensitivity, 87.9%; negative predictive value, 57.9%). TBNA established the diagnosis in 94% of patients with small cell lung cancer (SCLC), and in 88% of patients with non-SCLC (p = 0.7). Exclusive diagnosis was obtained in 36.4% of patients by histology (compared with 18.2% of patients by cytology [p = 0.06]), representing an increase of 35.3% in the diagnostic yield of TBNA over sole cytology examination. No major complication occurred. CONCLUSIONS: Histology specimens obtained exclusively with a 19-gauge TBNA needle enabled diagnosis in about 36% of patients with malignant intrathoracic lymphadenopathy. The routine use of a 19-gauge needle is safe.  相似文献   

2.
Endobronchial ultrasound   总被引:11,自引:0,他引:11  
Sheski FD  Mathur PN 《Chest》2008,133(1):264-270
During flexible fiberoptic bronchoscopy (FB), a solitary pulmonary nodule (SPN) is sampled by means of transbronchial needle aspiration (TBNA), brush, or transbronchial lung biopsy under fluoroscopy; and mediastinal lymph nodes are sampled using "blind" TBNA. Endobronchial ultrasound (EBUS) was developed to help visualize the lesion at the time of biopsy in order to improve the diagnostic yield. METHODS: There are two types of EBUS techniques: using a radial probe (RP) with a rotating transducer at the distal tip, which produces a 360 degrees image to the long axis of the bronchoscope; and using an EBUS bronchoscope with a linear transducer at its distal tip, producing a 50 degrees image parallel to its long axis. RESULTS: In biopsies of SPNs < 2 cm using an RP, EBUS demonstrates a higher diagnostic yield than conventional FB techniques. With mediastinal and hilar nodal stations, except for the subcarina, EBUS shows a higher yield over blind TBNA. The current procedural terminology code for EBUS is 31620, a "ZZZ" code submitted in addition to other performed procedures (31622-31638). In 2007, an estimate of physician Medicare reimbursement for EBUS is $70.49. Reimbursement is locality dependent and based on economic-exchange conversion factors. Incorporating an ultrasound image into the report substantiates the use of this technique. Limitations: The physician must learn ultrasound image interpretation and the EBUS technique, and be skilled in TBNA. Maintaining competency requires frequent performance of EBUS. CONCLUSION: EBUS-directed biopsy improves the yield over conventional FB for SPNs < 2 cm and for most mediastinal or hilar nodal stations. This reduces the need to conduct additional diagnostic procedures.  相似文献   

3.
BACKGROUND: The diagnostic yields with transbronchial needle aspiration (TBNA) for mediastinal nodes are highly variable. Nodal positions, as assessed on a breath-hold conventional CT scan, do not account for nodal motion. We studied nodal motion on four-dimensional (4D) CT scans. METHODS: A total of 47 mediastinal nodes were identified on 4D CT scans performed for radiotherapy planning in 25 patients with lung cancer. Nodes were mainly located at stations 4R, 4L, 7, and 2R, and each identified node was contoured in all 10 phases of the 4D CT scan. Nodal motion was correlated with changes in carina position. RESULTS: The mean (+/- SD) nodal diameter was 10.2 +/- 4.0 mm; and the mean nodal volume was 1.8 +/- 2.3 mL. Movement was maximal in the craniocaudal axis (mean length, 4.7 +/- 2.3 mm), and the corresponding mean mediolateral and ventrodorsal movements were 2.8 +/- 1.9 mm and 2.4 +/- 1.8 mm, respectively. The mean three-dimensional displacement of the nodal center was 6.2 +/- 2.9 mm, and it exceeded 10 mm in five nodes. The nodal mass was constantly present in only 25 +/- 14% of the region encompassing all nodal positions. The mean variation in craniocaudal distance between all nodes and the carina position during respiration was 5.3 +/- 2.1 mm (range, 2.2 to 10.5 mm). CONCLUSIONS: Both nodal motion and the varying distance between the carina and nodal position may explain the lower diagnostic yields for TBNA procedures performed without real-time guidance.  相似文献   

4.
STUDY OBJECTIVES: Transbronchial needle aspiration has evolved as a key bronchoscopic sampling method. Specimen handling and preparation are underrated yet crucial aspects of the technique. This study was designed to identify which of two widely practiced sample preparation methods has a higher yield. DESIGN: Prospective comparison of two diagnostic methods. SETTING: Tertiary academic hospital. PATIENTS: Consecutive patients undergoing transbronchial needle aspiration. INTERVENTIONS: Transbronchial aspirates were obtained pairwise. One specimen was placed directly onto a slide and smears were prepared on site (ie, the direct technique), and the other specimen was deposited into a vial containing 95% alcohol and further prepared in the laboratory (ie, the fluid technique). In total, 282 pairs of samples were aspirated from 145 target sites (paratracheal, 10 sites; tracheobronchial, 101 sites; hilar, 17 sites; endobronchial or peripheral, 17 sites). MEASUREMENTS AND RESULTS: The measured outcome was the presence of diagnostic material at the final laboratory assessment. At least one diagnostic aspirate was obtained in 66% of 86 investigated patients (small cell lung cancer, 18 patients; non-small cell lung cancer, 47 patients; other diagnoses, 21 patients). The direct technique had a better yield overall than the fluid technique (positive aspirates, 36.2% vs 12.4%, respectively; p < 0.01), as well as after stratification for tumor type and for anatomic site. CONCLUSION: The direct technique is superior to the fluid technique for the preparation of transbronchial needle aspirates.  相似文献   

5.
Herth FJ  Eberhardt R  Krasnik M  Ernst A 《Chest》2008,133(4):887-891
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) can reliably sample enlarged mediastinal lymph nodes in patients with non-small cell lung cancer (NSCLC), and in practice is mostly used to sample nodes visible on CT or positron emission tomography (PET). Few data are available on the use of endoscopic procedures to stage the mediastinum in clinical stage 1 lung cancer. The aim of the present study was to determine the results of EBUS-TBNA in sampling mediastinal lymph nodes in patients with lung cancer and a radiographically normal mediastinum and no PET activity. From January 2004 to May 2007, patients highly suspicious for NSCLC with CT scans showing no enlarged lymph nodes (no node > 1 cm) and a negative PET finding of the mediastinum underwent EBUS-TBNA. Identifiable lymph nodes at locations 2r, 2L, 4r, 4L, 7, 10r, 10L, 11r, and 11L were aspirated. All patients underwent subsequent surgical staging. Diagnoses based on aspiration results were compared with those based on surgical results. One hundred patients (mean age, 52.4 years; 59 men) were included. After surgery, 97 patients (mean age, 52.9 years; 57 men) had NSCLC confirmed and were included in the analysis. In this group, 156 lymph nodes ranging 5 to 10 mm in size were detected and sampled. Malignancy was detected in nine patients but missed in one patient. Mean diameter of the punctured lymph nodes was 7.9 mm. The sensitivity of EBUS-TBNA for detecting malignancy was 89%, specificity was 100%, and the negative predictive value was 98.9%. No complications occurred. In conclusion, EBUS-TBNA can be used to accurately sample and stage patients with clinical stage 1 lung cancer and no evidence of mediastinal involvement on CT and PET. Potentially operable patients with no signs of mediastinal involvement may benefit from presurgical staging with EBUS-TBNA.  相似文献   

6.
BACKGROUND AND OBJECTIVE: Several studies of real-time endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA) have reported a sensitivity of approximately 90% in the diagnosis of mediastinal and hilar malignancies. However, few studies have addressed its role in the diagnosis of sarcoidosis. The aim of the present study was to assess the utility of EBUS-TBNA in confirming a pathological diagnosis of sarcoidosis. METHODS: Fifteen consecutive patients with suspected sarcoidosis and mediastinal and/or hilar lymphadenopathy were investigated prospectively. EBUS-TBNA with an echo-bronchoscope and a dedicated echogenic 22-gauge needle was carried out in patients under conscious sedation, followed by conventional TBNA of the same lesion using a 19-gauge needle. RESULTS: EBUS-TBNA and/or TBNA demonstrated non-caseating epithelioid cell granulomas in 14 of 15 patients (93%). All 14 patients with a pathological diagnosis of sarcoidosis were considered to have sarcoidosis based on subsequent clinical assessments. The single patient with a negative EBUS-TBNA and TBNA had a malignant melanoma diagnosed following surgical biopsy. EBUS-TBNA confirmed a diagnosis of sarcoidosis in 13 of the 14 patients (93%) by identifying non-caseating epithelioid cell granulomas in 18 of 23 lymph nodes (78%) sampled. When two needle aspirates of one or two lymph nodes were carried out, the percentage positive pathological diagnosis for sarcoidosis for (i) EBUS-TBNA; (ii) TBNA; and (iii) the combination of EBUS-TBNA and TBNA were 93% (13 of 14 patients), 93% (13 of 14 patients) and 100% (14 of 14 patients), respectively. There were no complications associated with the procedures. CONCLUSION: EBUS-TBNA is less invasive and acceptably sensitive as a method for obtaining pathological confirmation of sarcoidosis.  相似文献   

7.
BACKGROUND: Somatic mutations of epidermal growth factor receptor (EGFR) are closely associated with an objective response to EGFR tyrosine kinase inhibitors. However, it is difficult to obtain sufficient tumor samples from patients with non-small cell lung cancer (NSCLC), so these diagnoses are often made using cytology procedures alone. The aim of this study was to detect EGFR mutations in transbronchial needle aspiration (TBNA) samples using both direct sequencing and a highly sensitive assay (Scorpions Amplified Refractory Mutation System; DxS; Manchester, UK) [ARMS], and to compare the sensitivity of these methods. METHODS: We enrolled 94 patients (63 men and 31 women) with NSCLC in this study. Cytologic diagnoses were adenocarcinoma (n = 58), squamous cell carcinoma (n = 24), and other types of NSCLC (n = 12). We extracted DNA from the TBNA samples, and EGFR mutations were analyzed using both direct sequencing (exons 19 and 21) and the Scorpions ARMS method (E746 A750del and L858R). RESULTS: Mutations were detected in 31 patients (33%; 14 women and 17 men). Of these, 23 patients had adenocarcinoma, 4 had squamous cell carcinoma, and 4 had other types of NSCLC. Direct sequencing detected 13 mutations (14%) in 13 patients (E746-A750del, n = 6; L858R, n = 7), and the Scorpions ARMS method detected 27 mutations (29%) in 27 patients (E746 A750del, n = 16; L858R, n = 11 patients). CONCLUSIONS: Both methods detected EGFR mutations in TBNA samples, but Scorpions ARMS is more sensitive than direct sequencing.  相似文献   

8.
Micames CG  McCrory DC  Pavey DA  Jowell PS  Gress FG 《Chest》2007,131(2):539-548
BACKGROUND: Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) is a minimally invasive alternative technique for mediastinal staging of non-small cell lung cancer. A metaanalysis was performed to estimate the diagnostic accuracy of EUS-FNA for staging mediastinal lymph nodes (N2/N3 disease) in patients with lung cancer. METHODS: Relevant studies were identified using Medline (1966 to November 2005), CINAHL, and citation indexing. Included studies used histology or adequate clinical follow-up (> 6 months) as the "gold standard," and provided sufficient data for calculating sensitivity and specificity. Summary receiver operating characteristic curves metaanalysis was performed to estimate the pooled sensitivity and specificity. RESULTS: In 18 eligible studies, EUS-FNA identified 83% of patients (95% confidence interval [CI], 78 to 87%) with positive mediastinal lymph nodes (pooled sensitivity) and 97% of patients (95% CI, 96 to 98%) with negative mediastinal lymph nodes (pooled specificity). In eight studies that were limited to patients who had abnormal mediastinal lymph nodes seen on CT scans, the sensitivity was 90% (95% CI, 84 to 94%) and the specificity was 97% (95% CI, 95 to 98%). In patients without abnormal mediastinal lymph nodes seen on CT scans (four studies), the pooled sensitivity was 58% (95% CI, 39 to 75%). Minor complications were reported in 10 cases (0.8%). There were no major complications. CONCLUSIONS: EUS-FNA is a safe modality for the invasive staging of lung cancer that is highly sensitive when used to confirm metastasis to mediastinal lymph nodes seen on CT scans. In addition, among lung cancer patients with normal mediastinal adenopathy seen on CT scans, despite lower sensitivity, it has the potential to prevent unnecessary surgery in a large proportion of cases missed by CT scanning.  相似文献   

9.
Tagaya R  Kurimoto N  Osada H  Kobayashi A 《Chest》2008,133(1):137-142
BACKGROUND: We investigated whether artificial neural networks (ANNs) could diagnose pathology of lymph nodes by feeding B-mode images from convex-type echobronchoscopy to ANNs. METHODS: Subjects comprised 91 patients who had undergone endobronchial ultrasonography transbronchial needle aspiration at our hospital between April 2005 and March 2007. Diagnosis was lymph node metastasis from lung cancer in 66 patients, and sarcoidosis in 25 patients. Layered ANNs consisting of input, middle layers, and output layers were prepared. Back-propagation was chosen as a learning algorithm. For the malignant findings, images obtained from six patients with lymph node metastasis of lung cancer (ie, adenocarcinoma, two patients; squamous cell carcinoma, two patients; small cell carcinoma, two patients) were used. As benign findings, typical images obtained from three patients with sarcoidosis were used. For each image used for supervised training, 5, 10, or 15 regions of interest were randomly selected. Repeated learning comprised either 500,000 or 1,000,000 repetitions. A total of five thoracic surgeons were asked to diagnose the pathology base on the same images. Accuracies were compared between ANNs and thoracic surgeons. RESULTS: The diagnostic accuracy of the surgeon with 5 years of experience and that of the surgeon with 1 year of experience were 78% and 51%, respectively, compared to 91% for the ANNs. CONCLUSION: Assessment of B-mode images by ANNs may offer a useful basis for automatic diagnostic methods.  相似文献   

10.
BACKGROUND: Previous reports suggest that sarcoidosis occurs with abnormally high frequency in firefighters. We sought to determine whether exposure to World Trade Center (WTC) "dust" during the collapse and rescue/recovery effort increased the incidence of sarcoidosis or "sarcoid-like" granulomatous pulmonary disease (SLGPD). METHODS: During the 5 years after the WTC disaster, enrollees in the Fire Department of New York (FDNY) WTC monitoring and treatment programs who had chest radiograph findings suggestive of sarcoidosis underwent evaluation, including the following: chest CT imaging, pulmonary function, provocative challenge, and biopsy. Annual incidence rates were compared to the 15 years before the WTC disaster. RESULTS: After WTC dust exposure, pathologic evidence consistent with new-onset sarcoidosis was found in 26 patients: all 26 patients had intrathoracic adenopathy, and 6 patients (23%) had extrathoracic disease. Thirteen patients were identified during the first year after WTC dust exposure (incidence rate, 86/100,000), and 13 patients were identified during the next 4 years (average annual incidence rate, 22/100,000; as compared to 15/100,000 during the 15 years before the WTC disaster). Eighteen of 26 patients (69%) had findings consistent with asthma. Eight of 21 patients (38%) agreeing to challenge testing had airway hyperreactivity (AHR), findings not seen in FDNY sarcoidosis patients before the WTC disaster. CONCLUSION: After the WTC disaster, the incidence of sarcoidosis or SLGPD was increased among FDNY rescue workers. This new information about the early onset of WTC-SLGPD and its association with asthma/AHR has important public health consequences for disease prevention, early detection, and treatment following environmental/occupational exposures.  相似文献   

11.
STUDY OBJECTIVES: We evaluated the feasibility and efficacy of transbronchial biopsy (TBB) and bronchial brushing by endobronchial ultrasonography (EBUS) with a guide sheath (GS) as a guide for diagnosing peripheral pulmonary lesions (PPLs) without radiographic fluoroscopy. PATIENTS: One hundred twenty-one patients with 123 PPLs (mean diameter, 31.0 mm) whose bronchoscopic findings were normal. METHODS: An EBUS-GS was inserted and advanced to the PPL without fluoroscopy. Once we obtained the EBUS image, the probe was withdrawn and the GS was left in place. TBB and/or bronchial brushing were performed via the GS. When an EBUS image could not be obtained, we changed to the bronchoscopic examination under fluoroscopy. RESULTS: Seventy-six of 123 PPLs (61.8%) were diagnosed by EBUS-GS guidance without fluoroscopy. The diagnostic yield for PPLs > 20 mm in diameter (75.6%) was significantly higher than that for those 相似文献   

12.
We encountered a 69-year-old woman displaying a filling defect within the left descending pulmonary artery (PA) on a chest CT scan and pulmonary angiography. A subsequent 2-[18F]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) scan demonstrated focal uptake in the left hilum. A cytologic examination of transbronchial needle aspiration specimens revealed small cell carcinoma. The patient underwent concurrent radiation therapy and chemotherapy with cisplatin and etoposide, resulting in tumor shrinkage and recanalization of the involved PA. This is the first case of small cell carcinoma localized exclusively within the PA, and positive findings on FDG-PET facilitated the unexpected diagnosis.  相似文献   

13.
Background and objective: Standard bronchoscopic techniques (transbronchial lung biopsy and endobronchial biopsy) provide a diagnosis in 70% of patients with pulmonary sarcoidosis. Previous data suggest that endobronchial ultrasound‐guided transbronchial needle aspiration (EBUS‐TBNA) has a high sensitivity in patients with sarcoidosis. The feasibility and utility of combining EBUS‐TBNA with standard bronchoscopic techniques is unknown. The aim of this study was to evaluate the feasibility, safety and efficacy of combined EBUS‐TBNA and standard bronchoscopic techniques in patients with suspected sarcoidosis and enlarged mediastinal or hilar lymphadenopathy. Methods: Forty consecutive patients with suspected pulmonary sarcoidosis and enlarged mediastinal or hilar lymph nodes (radiographical stage I and stage II) underwent EBUS‐TBNA followed by transbronchial biopsies and endobronchial biopsies under conscious sedation. Results: Thirty‐nine out of 40 patients successfully underwent combined EBUS‐TBNA and standard bronchoscopy. Twenty‐seven patients were diagnosed with sarcoidosis, eight had tuberculosis, two had reactive lymphadenopathy, two had lymphoma and one had metastatic adenocarcinoma. In patients with sarcoidosis, the sensitivity of EBUS‐TBNA for detection of non‐caseating granulomas was 85%, compared with a sensitivity of 35% for standard bronchoscopic techniques (P < 0.001). The diagnostic yield of combined EBUS‐TBNA and bronchoscopy was 93% (P < 0.0001). Conclusions: Combination of EBUS‐TBNA with standard bronchoscopic techniques is safe and feasible, and optimizes the diagnostic yield in patients with pulmonary sarcoidosis and enlarged intrathoracic lymphadenopathy.  相似文献   

14.
OBJECTIVES: The purpose of this study is to evaluate the prognostic importance of thin-section (TS) CT scan findings in small-sized lung adenocarcinomas. PATIENTS AND METHODS: We reviewed TS-CT scan findings and pathologic specimens from 359 consecutive patients who underwent surgical resection for peripheral lung adenocarcinomas 相似文献   

15.
Kaira K  Oriuchi N  Otani Y  Yanagitani N  Sunaga N  Hisada T  Ishizuka T  Endo K  Mori M 《Chest》2007,131(4):1019-1027
OBJECTIVES: L-[3-(18)F]-alpha-methyltyrosine ((18)F-FMT) is an amino-acid tracer for positron emission tomography (PET) and is used for tumor detection because malignant tumor cells accumulate (18)F-FMT based on the increased expression of an amino-acid transporter. This study was conducted to investigate the usefulness of (18)F-FMT PET in combination with fluorine-18-fluorodeoxyglucose ((18)F-FDG) PET for the diagnosis of sarcoidosis in patients with suspected malignancy. SETTING: Twenty-four sarcoidosis patients with suspected malignancy underwent (18)F-FDG and (18)F-FMT PET. The study included 17 patients with extrapulmonary manifestation mimicking malignant disease (13 patients with systemic lymphadenopathy, 3 of them with concomitant hepatosplenic processes; 3 patients with hepatosplenic processes without concomitant lymphadenopathy; and 1 patient with multiple bone lesions), 3 patients with occurrence of bilateral hilar lymphadenopathy in cancer patients, and 4 patients with multiple nodules mimicking pulmonary metastasis. RESULTS: All patients showed increased uptake of (18)F-FDG and no increase in the accumulation of (18)F-FMT in their lymphadenopathy. Standardized uptake values (SUVs) of (18)F-FDG and (18)F-FMT were 5.01 +/- 2.15 and 0.77 +/- 0.24, respectively (mean +/- SD). All extranodal lesions such as liver, spleen, and bone were visually positive on (18)F-FDG PET and negative on (18)F-FMT PET. No neoplasm was confirmed in all patients. In a control group of patients with lung cancer, SUVs for (18)F-FDG and (18)F-FMT were 6.34 +/- 2.52 and 1.54 +/- 0.82, respectively. CONCLUSION: The uptake of (18)F-FDG was positive in the sarcoid lesions, and therefore (18)F-FDG PET could not differentiate sarcoidosis from malignant disease. Use of (18)F-FMT PET in combination with (18)F-FDG PET may be the effective method to distinguish sarcoidosis from malignancy.  相似文献   

16.
Microscopic-sized "microthymoma" in patients with myasthenia gravis   总被引:1,自引:0,他引:1  
Mori T  Nomori H  Ikeda K  Kobayashi H  Iwatani K  Yoshioka M  Iyama K 《Chest》2007,131(3):847-849
BACKGROUND: In 2005, Cheuk et al reported two patients with microscopic-sized thymomas and proposed the term microthymoma to distinguish it from the nodular hyperplasia of thymic epithelium, so-called microscopic thymoma. Here, we present microthymomas that were found in 196 patients with myasthenia gravis (MG) who had undergone thymectomy. MATERIALS AND METHODS: Thymic tissues in 196 patients with MG who underwent thymectomy or thymothymomectomy were examined. Of these patients, 73 patients had thymoma indicated by CT before surgery, and the other 123 patients had no mediastinal tumors. From the resected thymic tissues, an average of 14 hematoxylin-eosin-stained sections (range, 4 to 55 sections) were prepared for microscopic examination. The histologic type of the thymoma was classified according to the World Health Organization (WHO) classification. RESULTS: From the 196 patients, we found three microthymomas in 3 patients (1.5%). While these three tumors could not be seen grossly in pathology section, they were found microscopically (range, 2 to 4 mm). The histologic subtype according to the WHO classification system was B1 in one patient and B2 in two patients. CONCLUSION: Microthymoma was found in 3 of 196 patients (1.5%) with MG. Microthymoma might exist in thymus of patients with MG, even in patients who have no thymoma indicated by CT.  相似文献   

17.
Lee YC  Wu CT  Kuo SW  Tseng YT  Chang YL 《Chest》2007,131(4):993-999
STUDY OBJECTIVES: Regional lymph node (LN) involvement affects the prognosis of patients with surgically resected non-small cell lung cancer (NSCLC). The significance of extranodal extension in these groups of patients was prospectively studied to determine its clinicopathologic relationships and its influence on patient survival. METHODS: A total of 199 NSCLC patients who were proved to have regional LN involvement after resection were included. Histologic examinations including tumor cell type, grade of differentiation, vascular invasion, regional LN metastasis emphasizing the number and station of LN involvement, the presence or absence of extranodal extension, and the immunohistochemistry of p53 expression were obtained. The relationships between extranodal extension and histologic type, grade of differentiation, vascular invasion, tumor size, pathologic stage, p53 expression, or patient survival were analyzed. RESULTS: Extranodal extension was significantly higher in women, adenocarcinoma, advanced stage, tumors with vascular invasion, or p53 overexpression. The total number and positive rate of resected LNs with extranodal extension were significantly correlated with advanced stage, tumors with vascular invasion, or p53 overexpression. By multivariate analysis of survival, the presence or total number of LNs with extranodal extension, tumor stage, and p53 expression were significant prognostic factors. The 5-year survival rate of stage IIIA patients without extranodal extension (30.4%) was significantly better than that of stage II patients with extranodal extension (16.8%). No survival difference between extranodal positive stage II and IIIA patients was noted. CONCLUSIONS: Extranodal extension of regional LNs is an important prognostic factor in patients with surgically resected NSCLC.  相似文献   

18.
19.
Itzhaki S  Dorchin H  Clark G  Lavie L  Lavie P  Pillar G 《Chest》2007,131(3):740-749
BACKGROUND: Obstructive sleep apnea (OSA) is associated with endothelial dysfunction. In the current study, we assessed the effect of long-term modified Herbst mandibular advancement splint (MAS) treatment on OSA, oxidative stress markers, and on endothelial function (EF). METHODS: A total of 16 subjects participated (11 men and 5 women; mean [+/- SD] age, 54.0 +/- 8.3 years; mean body mass index, 28.0 +/- 3.1 kg/m(2)), 12 of whom completed the 1-year evaluation. Apnea severity, levels of oxidative stress markers, and EF were assessed after 3 months and 1 year of receiving treatment. For comparison, 6 untreated patients underwent two evaluations 9 months apart, and 10 non-OSA individuals were assessed once as a reference group. The results are presented as the mean +/- SD. RESULTS: The mean apnea-hypopnea index (AHI) decreased significantly from 29.7 +/- 18.5 events/h before treatment to 17.7 +/- 11.1 events/h after 3 months of treatment and 19.6 +/- 11.5 events/h after 1 year of treatment (p < 0.005 for both). The mean Epworth sleepiness scale score decreased significantly from 12.4 +/- 6.0 before treatment to 10.2 +/- 6.6 after 3 months of treatment and 7.8 +/- 3.8 after 1 year of treatment (p < 0.001 for both). The mean EF improved significantly from 1.77 +/- 0.4 before treatment to 2.1 +/- 0.4 after 3 months of treatment (p < 0.05) and 2.0 +/- 0.3 after 1 year of treatment (p = 0.055), which were similar to the values of the reference group. Thiobarbituric acid-reactive substance (TBARS) levels decreased from 18.8 +/- 6.2 nmol malondialdehyde (MDA)/mL before treatment to 15.8 +/- 3.9 MDA/mL after 3 months of treatment (p = 0.09) and 15.5 +/- 3.2 nmol MDA/mL after 1 year of treatment (p < 0.05). There was a correlation between the improvement in AHI and in EF or TBARS levels (r = 0.55; p = 0.05). The untreated control group remained unchanged. CONCLUSIONS: The Herbst MAS may be a moderately effective long-term treatment for patients with OSA. EF improved to levels that were not significantly different than reference levels, even though apneic events were not completely eliminated. We think that these data are encouraging and that they justify the performance of larger randomized controlled studies.  相似文献   

20.
BACKGROUND: We investigated factors related to the diagnostic sensitivity of CT-guided transbronchial biopsy (TBB) using an ultrathin bronchoscope and virtual bronchoscopy (VB) navigation for small peripheral pulmonary lesions. METHOD: We have performed this procedure on 83 patients with 85 small peripheral pulmonary lesions (< 20 mm in diameter). We analyzed the relationship between the diagnostic sensitivity and the location of the lesions, the bronchial generation to which an ultrathin bronchoscope was inserted, and the lesion-bronchial and lesion-pulmonary arterial relationships on high-resolution CT. RESULTS: Fifty-six of the 85 lesions (66%) were diagnosed following CT-guided TBB using an ultrathin bronchoscope with VB navigation. The lesions located in the left superior segment of the lower lobe (S6) had a significantly low diagnostic sensitivity compared to other locations (p < 0.01). When an ultrathin bronchoscope could be inserted to the fifth or greater bronchial generation, the yield was above the average diagnostic sensitivity of 66%. Moreover, not only the patients with the presence of a bronchus leading directly to a lesion (CT-bronchus sign), but also the patients with the presence of a pulmonary artery leading to a lesion (CT-artery sign), had high diagnostic sensitivity (p < 0.01). Multivariate analysis revealed that the location of lesion was an independent predictor of diagnostic sensitivity (p < 0.05). CONCLUSIONS: The location of the lesion, the bronchial generation to which an ultrathin bronchoscope was inserted, and the presence of a bronchus as well as a pulmonary artery leading to the lesion were valuable for predicting successful CT-guided TBB using an ultrathin bronchoscope with VB navigation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号