首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Spin‐echo‐based pulse sequences are desirable for the application of high‐resolution imaging of trabecular bone but tend to involve high‐power deposition. Increased availability of ultrahigh field scanners has opened new possibilities for imaging with increased signal‐to‐noise ratio (SNR) efficiency, but many pulse sequences that are standard at 1.5 and 3 T exceed specific absorption rate limits at 7 T. A modified, reduced specific absorption rate, three‐dimensional, fast spin‐echo pulse sequence optimized specifically for in vivo trabecular bone imaging at 7 T is introduced. The sequence involves a slab‐selective excitation pulse, low‐power nonselective refocusing pulses, and phase cycling to cancel undesired out‐of‐slab signal. In vivo images of the distal tibia were acquired using the technique at 1.5, 3, and 7 T field strengths, and SNR was found to increase at least linearly using receive coils of identical geometry. Signal dependence on the choice of refocusing flip angles in the echo train was analyzed experimentally and theoretically by combining the signal from hundreds of coherence pathways, and it is shown that a significant specific absorption rate reduction can be achieved with negligible SNR loss. Magn Reson Med 63:719–727, 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

2.
Most diffusion imaging sequences rely on single‐shot echo‐planar imaging (EPI) for spatial encoding since it is the fastest acquisition available. However, it is sensitive to chemical‐shift artifacts due to the low bandwidth in the phase‐encoding direction, making fat suppression necessary. Often, spectral‐selective RF pulses followed by gradient spoiling are used to selectively saturate the fat signal. This lengthens the acquisition time and increases the specific absorption rate (SAR). However, in pulse sequences that contain two slice‐selective 180° refocusing pulses, the slice‐selection gradient reversal (SSGR) method of fat suppression can be implemented; i.e., using slice‐selection gradients of opposing polarity for the two refocusing pulses. We combined this method with the twice‐refocused spin‐echo sequence for diffusion encoding and tested its performance in both phantoms and in vivo. Unwanted fat signal was entirely suppressed with this method without affecting the water signal intensity or the slice profile. Magn Reson Med 60:1256–1260, 2008. © 2008 Wiley‐Liss, Inc.  相似文献   

3.
A “featherlike” artifact, termed a cusp artifact, is sometimes seen along the phase‐encoding direction in sagittal or coronal fast spin echo images. This artifact arises from the spins, at a location distant from the magnet isocenter, that are excited and aliased to the field of view because their precession frequency is similar to those at the isocenter. Such a situation is created due to a combination of excessive gradient nonlinearity and rapid change of the main magnetic field near the edge of the magnet where the artifact‐producing spins are located. A novel technique is proposed to reduce this artifact, in which a fast spin echo pulse sequence is modified to slightly tilt the slice selected by the radiofrequency excitation pulse away from the slice selected by the radiofrequency refocusing pulses. At the edge of the field of view, the incomplete overlap between the slices selected by the excitation and refocusing pulses effectively reduces the signals from the artifact‐prone region. In contrast, the slices overlap substantially within the field of view so that the signals are largely retained. This slice‐tilting technique has been implemented on two commercial MRI scanners operating at 3.0 T and 1.5 T, respectively, and evaluated on phantoms and human spine and extremities using clinical protocols. Both phantom and human results showed that the technique decreased the strength of the cusp artifact by at least 65% and substantially limited the spatial extent of the artifact. This technique, which can be further enhanced by a simple postprocessing step, offers significant advantages over a number of other techniques for reducing the fast spin echo cusp artifact. It can be implemented on virtually any scanner without hardware modification, complicated calibration, sophisticated image reconstruction, or patient‐handling alteration. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

4.

Purpose:

To demonstrate the feasibility of two‐dimensional selective radio frequency (2DRF) excitations for fast‐spin‐echo imaging of inner fields‐of‐view (FOVs) in order to shorten acquisitions times, decrease RF energy deposition, and reduce image blurring.

Materials and Methods:

Fast‐spin‐echo images (in‐plane resolution 1.0 × 1.0 mm2 or 0.5 × 1.0 mm2) of inner FOVs (40 mm, 16 mm oversampling) were obtained in phantoms and healthy volunteers on a 3 T whole‐body MR system using blipped‐planar 2DRF excitations.

Results:

Positioning the unwanted side excitations in the blind spot between the image section and the slice stack to measure yields minimum 2DRF pulse durations (about 6 msec) that are compatible with typical echo spacings of fast‐spin‐echo acquisitions. For the inner FOVs, the number of echoes and refocusing RF pulses is considerably reduced which compared to a full FOV (182 mm) reduces the RF energy deposition by about a factor of three and shortens the acquisition time, e.g., from 39 seconds to 12 seconds for a turbo factor of 15 or from 900 msec to 280 msec for a single‐shot acquisition, respectively. Furthermore, image blurring occurring for high turbo factors as in single‐shot acquisitions is considerably reduced yielding effectively higher in‐plane resolutions.

Conclusion:

Inner‐FOV acquisitions using 2DRF excitations may help to shorten acquisitions times, ameliorate image blurring, and reduce specific absorption rate (SAR) limitations of fast‐spin‐echo (FSE) imaging, in particular at higher static magnetic fields. J. Magn. Reson. Imaging 2010;31:1530–1537. © 2010 Wiley‐Liss, Inc.  相似文献   

5.
Frequency‐modulated (FM) pulses have practical advantages for spin‐echo experiments, such as the ability to produce a broadband π rotation, with an inhomogeneous radiofrequency (RF) field. However, such use leads to a nonlinear phase of the transverse magnetization, which is why FM pulses like the hyperbolic secant (HS) pulse are not commonly used for multislice spin‐echo magnetic resonance imaging (MRI). Here, a general theory and methods are described for conventional spin‐echo imaging using a π HS pulse for refocusing. Phase profiles produced by the HS pulse are analytically described. The analysis is extended to yield the specific relationships between pulse parameters and gradients, which must be satisfied to compensate the nonlinear phase variation produced with a spin‐echo sequence composed of π/2 and π HS pulses (the π/2 HS ? π HS sequence). The latter offers advantages for multislice spin‐echo MRI, including excellent slice‐selection and partial compensation for RF inhomogeneity. Furthermore, it can be implemented with a shorter echo time and lower power deposition than a previously described method using a pair of π HS pulses. Magn Reson Med 61:175–187, 2009. © 2008 Wiley‐Liss, Inc.  相似文献   

6.
PURPOSE: To propose new frequency offset corrected inversion (FOCI) pulses with significantly reduced radiofrequency (RF) power deposition for spin echo imaging by incorporating the variable-rate selective excitation (VERSE) schemes into the pulse design. MATERIALS AND METHODS: Two schemes are proposed to design the new FOCI pulses with dramatically reduced peak RF power requirements. In scheme A, the time-dilation function is derived from a predefined adiabaticity factor modulation function. In scheme B, the time-dilation function is predefined, while the adiabaticity factor is conserved. RESULTS: The new FOCI pulses are shown to be able to operate at reduced specific absorption rate (SAR), specifically at the same peak RF power as that of a five- or seven-lobe sinc inversion pulse of the same duration. Using the new FOCI pulse, significant gain in sensitivity was observed in in vivo spin-echo echo-planar imaging, which was attributed to the improved refocusing slice profile. CONCLUSION: The new FOCI pulses can replace the 180 degrees five- or seven-lobe sinc pulses in spin-echo imaging with the same peak RF power requirement and significantly improved slice profile.  相似文献   

7.
Spin‐echo‐based acquisitions are the workhorse of clinical MRI because they provide a variety of useful image contrasts and are resistant to image artifacts from radio‐frequency or static field inhomogeneity. Three‐dimensional (3D) acquisitions provide datasets that can be retrospectively reformatted for viewing in freely selectable orientations, and are thus advantageous for evaluating the complex anatomy associated with many clinical applications of MRI. Historically, however, 3D spin‐echo‐based acquisitions have not played a significant role in clinical MRI due to unacceptably long acquisition times or image artifacts associated with details of the acquisition method. Recently, optimized forms of 3D fast/turbo spin‐echo imaging have become available from several MR‐equipment manufacturers (for example, CUBE [GE], SPACE [Siemens], and VISTA [Philips]). Through specific design strategies and optimization, including short non–spatially selective radio‐frequency pulses to significantly shorten the echo spacing and variable flip angles for the refocusing radio‐frequency pulses to suppress blurring or considerably lengthen the useable duration of the spin‐echo train, these techniques permit single‐slab 3D imaging of sizeable volumes in clinically acceptable acquisition times. These optimized fast/turbo spin‐echo pulse sequences provide a robust and flexible approach for 3D spin‐echo‐based imaging with a broad range of clinical applications. J. Magn. Reson. Imaging 2014;39:745–767. © 2014 Wiley Periodicals, Inc .  相似文献   

8.
Single‐shot echo‐planar imaging (ss‐EPI) has not been used widely for diffusion‐weighted imaging (DWI) of the spinal cord, because of the magnetic field inhomogeneities around the spine, the small cross‐sectional size of the spinal cord, and the increased motion in that area due to breathing, swallowing, and cerebrospinal fluid (CSF) pulsation. These result in artifacts with the usually long readout duration of the ss‐EPI method. Reduced field‐of‐view (FOV) methods decrease the required readout duration for ss‐EPI, thereby enabling its practical application to imaging of the spine. In this work, a reduced FOV single‐shot diffusion‐weighted echo‐planar imaging (ss‐DWEPI) method is proposed, in which a 2D spatially selective echo‐planar RF excitation pulse and a 180° refocusing pulse reduce the FOV in the phase‐encode (PE) direction, while suppressing the signal from fat simultaneously. With this method, multi slice images with higher in‐plane resolutions (0.94 × 0.94 mm2 for sagittal and 0.62 × 0.62 mm2 for axial images) are achieved at 1.5 T, without the need for a longer readout. Magn Reson Med 60:468–473, 2008. © 2008 Wiley‐Liss, Inc.  相似文献   

9.
The conventional stimulated‐echo NMR sequence only measures the longitudinal component while discarding the transverse component, after tipping up the prepared magnetization. This transverse magnetization can be used to measure a spin echo, in addition to the stimulated echo. Two‐dimensional single‐shot spin‐ and stimulated‐echo‐planar imaging (ss‐SESTEPI) is an echo‐planar‐imaging‐based single‐shot imaging technique that simultaneously acquires a spin‐echo‐planar image and a stimulated‐echo‐planar image after a single radiofrequency excitation. The magnitudes of the spin‐echo‐planar image and stimulated‐echo‐planar image differ by T1 decay and diffusion weighting for perfect 90° radiofrequency and thus can be used to rapidly measure T1. However, the spatial variation of amplitude of radiofrequency field induces uneven splitting of the transverse magnetization for the spin‐echo‐planar image and stimulated‐echo‐planar image within the imaging field of view. Correction for amplitude of radiofrequency field inhomogeneity is therefore critical for two‐dimensional ss‐SESTEPI to be used for T1 measurement. We developed a method for amplitude of radiofrequency field inhomogeneity correction by acquiring an additional stimulated‐echo‐planar image with minimal mixing time, calculating the difference between the spin echo and the stimulated echo and multiplying the stimulated‐echo‐planar image by the inverse functional map. Diffusion‐induced decay is corrected by measuring the average diffusivity during the prescanning. Rapid single‐shot T1 mapping may be useful for various applications, such as dynamic T1 mapping for real‐time estimation of the concentration of contrast agent in dynamic contrast enhancement MRI. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

10.

Purpose:

To demonstrate reduced field‐of‐view (RFOV) single‐shot fast spin echo (SS‐FSE) imaging based on the use of two‐dimensional spatially selective radiofrequency (2DRF) pulses.

Materials and Methods:

The 2DRF pulses were incorporated into an SS‐FSE sequence for RFOV imaging in both phantoms and the human brain on a 1.5 Tesla (T) whole‐body MR system with the aim of demonstrating improvements in terms of shorter scan time, reduced blurring, and higher spatial resolution compared with full FOV imaging.

Results:

For phantom studies, scan time gains of up to 4.2‐fold were achieved as compared to the full FOV imaging. For human studies, the spatial resolution was increased by a factor of 2.5 (from 1.7 mm/pixel to 0.69 mm/pixel) for RFOV imaging within a scan time (0.7 s) similar to full FOV imaging. A 2.2‐fold shorter scan time along with a significant reduction of blurring was demonstrated in RFOV images compared with full FOV images for a target spatial resolution of 0.69 mm/pixel.

Conclusion:

RFOV SS‐FSE imaging using a 2DRF pulse shows advantages in scan time, blurring, and specific absorption rate reduction along with true spatial resolution increase compared with full FOV imaging. This approach is promising to benefit fast imaging applications such as image guided therapy. J. Magn. Reson. Imaging 2010;32:242–248. © 2010 Wiley‐Liss, Inc.  相似文献   

11.
Conventional T2‐weighted turbo/fast spin echo imaging is clinically accepted as the most sensitive method to detect brain lesions but generates a high signal intensity of cerebrospinal fluid (CSF), yielding diagnostic ambiguity for lesions close to CSF. Fluid‐attenuated inversion recovery can be an alternative, selectively eliminating CSF signals. However, a long time of inversion, which is required for CSF suppression, increases imaging time substantially and thereby limits spatial resolution. The purpose of this work is to develop a phase‐sensitive, dual‐acquisition, single‐slab, three‐dimensional, turbo/fast spin echo imaging, simultaneously achieving both conventional T2‐weighted and fluid‐attenuated inversion recovery–like high‐resolution whole‐brain images in a single pulse sequence, without an apparent increase of imaging time. Dual acquisition in each time of repetition is performed, wherein an in phase between CSF and brain tissues is achieved in the first acquisition, while an opposed phase, which is established by a sequence of a long refocusing pulse train with variable flip angles, a composite flip‐down restore pulse train, and a short time of delay, is attained in the second acquisition. A CSF‐suppressed image is then reconstructed by weighted averaging the in‐ and opposed‐phase images. Numerical simulations and in vivo experiments are performed, demonstrating that this single pulse sequence may replace both conventional T2‐weighted imaging and fluid‐attenuated inversion recovery. Magn Reson Med 63:1422–1430, 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

12.
A “half‐pulse” slice selection approach is used in the ultrashort echo time pulse sequence and is required to give minimal transverse relaxation in a two‐dimensional acquisition. This method splits the normal excitation radiofrequency pulse in half and acquires a pair of images, each using one of these half‐pulses. These half‐pulses are used without a refocusing gradient since summing the pair of images yields images with accurate slice selection. When the radiofrequency pulse duration is similar to the sample T2, characteristics such as the effective echo time and choice of radiofrequency pulse require careful evaluation as some of the approximations in conventional slice selection do not apply. We derive a theory that includes relaxation during excitation using Pauly's excitation k‐space formalism. Further, this theory is tested on phantoms with a range of values of T2 demonstrating the effect on the slice profile. We conclude that relaxation during excitation is significant and should be included in our estimate of the T2 weighting of the sequence. In general, the T2 weighting should be measured from the time of the centroid of the excitation pulse. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

13.
An implementation of fast spin echo at 4.7 T designed for versatile and time‐efficient T2‐weighted imaging of the human brain is presented. Reduced refocusing angles (α < 180°) were employed to overcome specific absorption rate (SAR) constraints and their effects on image quality assessed. Image intensity and tissue contrast variations from heterogeneous RF transmit fields and incidental magnetization transfer effects were investigated at reduced refocusing angles. We found that intraslice signal variations are minimized with refocusing angles near 180°, but apparent gray/white matter contrast is independent of refocusing angle. Incidental magnetization transfer effects from multislice acquisitions were shown to attenuate white matter intensity by 25% and gray matter intensity by 15% at 180°; less than 5% attenuation was seen in all tissues at flip angles below 60°. We present multislice images acquired without excess delay time for SAR mitigation using a variety of protocols. Subsecond half Fourier acquisition single‐shot turbo spin echo (HASTE) images were obtained with a novel variable refocusing angle echo train (20° < α < 58°) and high‐resolution scans with a voxel volume of 0.18 mm3 were acquired in 6.5 min with refocusing angles of 100°. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.  相似文献   

14.
The selective multiple quantum coherence technique is combined with a read gradient to accelerate the measurement of a specific scalar‐coupled metabolite. The sensitivities of the localization using pure phase encoding and localization with the read gradient are compared in experiments at high magnetic field strength (17.6 T). Multiple spin‐echoes of the selective multiple quantum coherence edited metabolite are acquired using frequency‐selective refocusing of the specified molecule group. The frequency‐selective refocusing does not affect the J‐modulation of a coupled spin system, and the echo time is not limited to a multiple of 1/J to acquire pure in‐phase or antiphase signal. The multiple echoes can be used to accelerate the metabolite imaging experiment or to measure the apparent transverse relaxation T2. A simple phase‐shifting scheme is presented, which enables the suppression of editing artifacts resulting from the multiple spin‐echoes of the water resonance. The experiments are carried out on phantoms, in which lactate and polyunsaturated fatty acids are edited, and in vivo on tumors, in which lactate content and T2 are imaged. The method is of particular interest when a fast and sensitive selective multiple quantum coherence editing is necessary, e.g., for spatial three dimensional experiments. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.  相似文献   

15.
Single‐slab 3D turbo/fast spin echo (SE) imaging with very long echo trains was recently introduced with slab selection using a highly selective excitation pulse and short, nonselective refocusing pulses with variable flip angles for high imaging efficiency. This technique, however, is vulnerable to image degradation in the presence of spatially varying B1 amplitudes. In this work we develop a B1 inhomogeneity‐reduced version of single‐slab 3D turbo/fast SE imaging based on the hypothesis that it is critical to achieve spatially uniform excitation. Slab selection was performed using composite adiabatic selective excitation wherein magnetization is tipped into the transverse plane by a nonselective adiabatic‐half‐passage pulse and then slab is selected by a pair of selective adiabatic‐full‐passage pulses. Simulations and experiments were performed to evaluate the proposed technique and demonstrated that this approach is a simple and efficient way to reduce B1 sensitivity in single‐slab 3D turbo/fast SE imaging with very long echo trains. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.  相似文献   

16.
Combined acquisition of gradient‐echo and spin‐echo signals in MRI time series reveals additional information for perfusion‐weighted imaging and functional MRI because of differences in the sensitivity of gradient‐echo and spin‐echo measurements to the properties of the underlying vascular architecture. The acquisition of multiple echo trains within one time frame facilitates the simultaneous estimation of the transversal relaxation parameters R2 and R. However, the simultaneous estimation of these parameters tends to be incorrect in the presence of slice profile mismatches between signal excitation and subsequent refocusing pulses. It is shown here that improvements in pulse design reduced R2 and R estimation errors. Further improvements were achieved by augmented parameter estimation through the introduction of an additional parameter δ to correct for discordances in slice profiles to facilitate more quantitative measurements. Moreover, the analysis of time‐resolved acquisitions revealed that the temporal stability of R2 estimates could be increased with improved pulse design, counteracting low contrast‐to‐noise ratios in spin‐echo‐based perfusion and functional MRI. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.  相似文献   

17.
Single‐shot echo‐planar imaging is the most common acquisition technique for whole‐brain diffusion tensor imaging (DTI) studies in vivo. Higher field MRI systems are readily available and advantageous for acquiring DTI due to increased signal. One of the practical issues for DTI with single‐shot echo‐planar imaging at high‐field is incomplete fat suppression resulting in a chemically shifted fat artifact within the brain image. Unsuppressed fat is especially detrimental in DTI because the diffusion coefficient of fat is two orders of magnitude lower than that of parenchyma, producing brighter appearing fat artifacts with greater diffusion weighting. In this work, several fat suppression techniques were tested alone and in combination with the goal of finding a method that provides robust fat suppression and can be used in high‐resolution single‐shot echo‐planar imaging DTI studies. Combination of chemical shift saturation with slice‐select gradient reversal within a dual‐spin‐echo diffusion preparation period was found to provide robust fat suppression at 3 T. Magn Reson Med, 2011. © 2011 Wiley Periodicals, Inc.  相似文献   

18.
Phase‐sensitive dual‐acquisition single‐slab three‐dimensional turbo spin echo imaging was recently introduced, producing high‐resolution isotropic cerebrospinal fluid attenuated brain images without long inversion recovery preparation. Despite the advantages, the weighted‐averaging‐based technique suffers from noise amplification resulting from different levels of cerebrospinal fluid signal modulations over the two acquisitions. The purpose of this work is to develop a signal‐to‐noise ratio‐optimized version of the phase‐sensitive dual‐acquisition single‐slab three‐dimensional turbo spin echo. Variable refocusing flip angles in the first acquisition are calculated using a three‐step prescribed signal evolution while those in the second acquisition are calculated using a two‐step pseudo‐steady state signal transition with a high flip‐angle pseudo‐steady state at a later portion of the echo train, balancing the levels of cerebrospinal fluid signals in both the acquisitions. Low spatial frequency signals are sampled during the high flip‐angle pseudo‐steady state to further suppress noise. Numerical simulations of the Bloch equations were performed to evaluate signal evolutions of brain tissues along the echo train and optimize imaging parameters. In vivo studies demonstrate that compared with conventional phase‐sensitive dual‐acquisition single‐slab three‐dimensional turbo spin echo, the proposed optimization yields 74% increase in apparent signal‐to‐noise ratio for gray matter and 32% decrease in imaging time. The proposed method can be a potential alternative to conventional fluid‐attenuated imaging. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

19.
A robust modification of echo‐planar imaging dubbed double‐shot echo‐planar imaging with center‐out trajectories and intrinsic navigation (DEPICTING) is proposed, which permits imaging at ultra‐short echo time. The k‐space data is sampled by two center‐out trajectories with a minimal delay achieving a temporal efficiency similar to conventional single‐shot echo‐planar imaging. Intersegment phase and intensity imperfections are corrected by exploiting the intrinsic navigator information from both central lines, which are subsequently averaged for image reconstruction. Phase errors induced by inhomogeneities of the main magnetic field are corrected in k‐space, recovering the superior point‐spread function achieved with center‐out trajectories. The minimal echo time (<2 msec) is nearly independent of the acquisition matrix permitting applications, which simultaneously require high spatial and temporal resolution. Examples of demonstrated applications include anatomical imaging, BOLD‐based functional brain mapping, and quantitative perfusion imaging. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

20.
A 3D inner-volume fast spin echo (3D IV-FSE) sequence was developed for ECG-gated, black-blood, T1- and T2-weighted vessel wall imaging of peripheral vein bypass grafts (PVBG). The sequence utilizes nonselective refocusing excitations to minimize echo spacings and a highly selective IV excitation scheme to minimize the need for oversampling of z-encode slice selections. The method was tested in eight PVBG patients who also underwent 2D FSE graft imaging. High-quality 3D imaging was achieved in all subjects, with significant spatial resolution and volume coverage gains compared to the more conventional 2D FSE sequences normalized for signal-to-noise ratios (SNRs) and scan times. Compared to previously proposed 3D IV-FSE methods, nonselective refocusing resulted in a more than 20% FSE echo train sampling efficiency increase while the use of highly selective IV excitation resulted in a 30% improvement in slice oversampling efficiency.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号