1.
目的 评价非球面人工晶状体(IOL)AcrySof IQ IOL植入术后年龄相关性白内障患者的视觉质量.方法 年龄相关性白内障患者42例55眼,按随机数字表法将患者分成两组.其中非球面人工晶体组24例(28眼),植入AcrySof IQ IOL;球面人工晶体组18例(27眼),植入AcrySof Natural IOL.术后随访3个月的裸眼视力(UCVA)、最佳矫正远视力(BCVA),不同亮度环境下的对比敏感度等.结果 手术后3个月非球面组UCVA为0.76±0.18,优于球面组的0.66±0.17,差异有统计学意义(P<0.05).非球面组BCVA为0.85±0.19,优于球面组的0.74±0.19,差异有统计学意义(P<0.05).两组球镜、柱镜差异无统计学意义(P>0.05).在明视觉条件下,非球面组在12.0 cpd、18.0 cpd的对比敏感度明显优于球面组(P<0.01).在暗视觉条件下非球面组所有空间频率的对比敏感度非球面组均优于球面组(P<0.05).非球面组眩光、光晕等的发生率均低于球面组(P<0.05).结论 白内障术后早期,非球面人工晶状体能够提供较好的术后裸眼视力、最佳矫正远视力、亮环境下高频对比敏感度和暗环境下的所有空间频率的对比敏感度,提示非球面人工晶状体能够提供较好的视觉质量.  相似文献   

2.
目的评估高度近视合并白内障的患者双眼植入非球面多焦点人工晶状体AcrySof IQ ReSTOR的临床效果方法随机选取26例(52眼)高度近视合并白内障患者,接受白内障超声乳化吸除联合人工晶状体植入术。实验组(MIOL组,13例26眼)双眼植入非球面多焦点人工晶状体AcrySof IQ ReSTOR,对照组(IQ组,13例26眼)双眼植入非球面人工晶状体AcrySof IQ。检测术前视力、术后3个月裸眼远视力、最佳矫正远视力、裸眼近视力、最佳矫正近视力、屈光状态,问卷调查术后视近时对眼镜的依赖程度及患者的主观视觉症状。结果术后3个月,两组裸眼远视力、最佳矫正远视力、最佳矫正近视力、整体满意度、眩光、夜间视物模糊及色觉异常,差异均无统计学意义(P0.05);而MIOL组裸眼近视力,视近距时满意度和视近距时脱镜率,MIOL组优于IQ组(P0.05),差异有统计学意义。结论与非球面人工晶状体AcrySof IQ相比,高度近视合并白内障患者应用AcrySof IQ ReSTOR具有更好的视觉效果,近距离工作脱镜率高。  相似文献   

3.
目的:探讨超声乳化联合植入不同非球面人工晶体治疗白内障术后视觉及对比敏感度变化情况。 方法:将72例96眼白内障患者分为A组、B组、C组,每组24例32眼,均给予超声乳化联合植入非球面人工晶体,A组采用AcrySof ReSTOR+3D(SN6AD1)多焦点非球面人工晶体,B组采用AcrySof ReSTOR+4D(SN6AD3)多焦点非球面人工晶体,C组采用单焦点球面人工晶体。比较3组患者术后1 d、1周、1个月的裸眼和矫正视力,以及不同照明条件和空间频率下的对比敏感度。结果:A组术后1 d、1周、1个月的裸眼视力显著优于B组和C组(PP>0.05),但均优于C组(PPP>0.05);非眩光(3 cd/m2)条件下,在3 c/d、6 c/d的低空间频率下A组和B组对比敏感度显著优于C组(P2)条件下,A组和B组对比敏感度均显著优于C组(P结论:超声乳化联合人工晶体植入术能够显著改善白内障患者的视觉质量,而与单焦点球面人工晶体相比,多焦点非球面人工晶体对患者对比敏感度的改善更佳,其中AcrySof ReSTOR+3D(SN6AD1)多焦点非球面人工晶体能够更显著地提高患者的中距离视力,值得临床推广应用。  相似文献   

4.
目的:对比观察老年性白内障超声乳化吸除术后分别植入非球面和球面人工晶状体后患眼对比敏感度的差异。研究对象:单纯老年性白内障患者(除外其他眼病)54例(71眼),按照植入非球面或球面人工晶状体的类型不同分为2组:球面人工晶体组例26例(34眼),非球面人工晶状体组28例(37眼)。方法:患者术眼行白内障超化吸出术后分别植入预装式非球面或预装式球面人工晶状体,术后3个月观察2组患者视力、最佳矫正视力、人工晶状体居中情况、屈光状态,检查患者的对比敏感度、眩光敏感度。主要指标:最佳矫正视力,瞳孔6 mm的对比敏感度、眩光敏感度。结果:瞳孔6mm时2组间术后最佳矫正视力、对比敏感度及眩光敏感度存在差异,并有无统计学意义。结论:非球面人工晶状体较普通的球面人工晶状体视力及对比敏感度有改善。  相似文献   

5.
目的 研究伴有角膜散光的高度近视白内障患者进行超声乳化+环曲面人工晶状体(Toric intraocular lens, Toric IOL)及囊袋张力环(capsular tension ring, CTR)植入术的临床效果及稳定性。方法 通过回顾性研究,分析在武汉市第一医院行白内障超声乳化吸除术的高度近视伴有角膜散光的患眼54例(76眼),其中31例(38眼)联合植入Toric IOL及CTR(联合组),23例(38眼)单纯植入Toric IOL(对照组)。术后随访6个月,比较两组患者术前及术后视力、角膜内皮细胞密度、人工晶状体旋转度、残余散光度,以及并发症发生情况。结果 术后6月,两组患者裸眼远视力(uncorrected distance visual acuity, UCVA)、最佳矫正视力(best corrected visual acuity, BCVA)均显著高于术前,联合组术后UCVA(LogMAR)优于对照组,差异有统计学意义[(0.34±0.15)vs.(0.46±0.25),P<0.05]。术后1周、1月、3月及6月,联合组散光分别为(0.38±0.31...  相似文献   

6.
目的白内障术后的视觉质量因人工晶状体的设计改进而显著改善。文中研究非球面人工晶状体植入术后患眼高阶像差及对比敏感度的特点,评价非球面人工晶状体对术眼视觉质量的影响。方法患者共80只眼分为2组,一组植入非球面人工晶状体Acrysoft SN60WF,一组植入球面人工晶状体Acrysoft SA60AT。术后进行角膜地形图波前像差及对比敏感度的测量。结果术后的最佳矫正视力及角膜高阶像差比较组间差异无统计学意义(P>0.05)。术后的高阶像差测量显示球面像差Zernike C12、4阶高阶像差及总体像差比较中SA60AT组大于SN60WF组,组间差异均具有统计学意义。眩光对比敏感度,在空间频率6、12、18c/d时,SN60WF组大于SA60AT组(P<0.05)。结论非球面人工晶状体可以减少球面像差,增加对比敏感度。  相似文献   

7.
目的:比较球面和非球面人工晶状体(IOL)植入术后患者的视觉质量。方法:选取老年性白内障患者36例(72眼)作为观察对象,根据植入的IOL不同将其分为620H组(球面IOL)和970C组(非球面IOL)。比较两组角膜Q值和IOL偏心值;术后6个月瞳孔6 mm的高阶像差、敏感度(CS)、眩光敏感度(GS)和高阶像差包括四阶球差(Z40)、四阶球差均方根(RMS4)、高阶像差均方根(RMSh)和四阶彗差(Z7、Z8)。结果:970C组Z40、RMS4、RMSh均明显低于620H组,在6.3°、4.0°视角的CS及GS均明显大于620H,差异均具有统计学意义(P<0.05),两组角膜Q值和IOL偏心值比较差异无统计学意义(P>0.05)。结论:非球面IOL植入术后的视觉质量优于球面IOL植入术。  相似文献   

8.
非球面衍射型多焦点人工晶状体植入术后视觉质量评价   总被引:1,自引:0,他引:1  
目的 评价非球面多焦点人工晶状体(AcrySof IQ ReSTOR IOL SN6AD3)植入术后的视觉质量.方法 对植入非球面多焦点人工晶状体的老年性白内障患者30例(35只眼)(试验组)与植入球面多焦点人工晶状体(AcrySof ReSTOR 10L SN60D3)患者40例(56只眼)(对照组)进行对比研究.观察患者的术后视力(远视力,70 cm中距视力,近视力)、焦点深度、高阶像差、对比敏感度和眩光敏感度,问卷形式调查视觉不良症状及满意度.结果 术后3个月裸眼近、远、中间视力≥0.5者,试验组分别为80%(20/35)、82.9%(29/35)、45.7%(16/35),对照组分别为76.8%(43/56)、80.4%(45/56)、39.3%(22/56),两组比较差异无统计学意义(P>0.05);术后3个月最佳矫正远视力下近、远、中间视力≥0.5者,试验组分别为88.6%(31/35)、91.4%(32/35)、54.3%(19/35),对照组分别为81.5%(49/56)、91.1%(51/56)、42.9%(24/56),两组比较差异无统计学意义(P<0.05).术后3个月试验组各频段对比敏感度和眩光敏感度高于对照组,差异有统计学意义(P<0.05).在+1.00~-1.00D,-1.50D和-2.50~-3.50D调节范围内,视力≥0.5者试验组分别为94.3%(33/35)、97.1%(34/35)、85.7%(30/35),对照组分别92.9%(52/56)、94.6%(53/56)、83.9%(47/56),两组比较差异无统计学意义(P>0.05).高阶像差Zemike常数项中两组的Z(4,0)、Z(4,2)、S3+S4和S总系数差异有统计学意义(P<0.05),其余的Zernike常数项、三阶像差和四阶像差各指标间两组比较差异无统计学意义(P>0.05).两组均无严重眩光症状,对照组有3眼诉有光晕症状,试验组仅有1眼诉有光晕症状,满意程度较高.结论 AcrySof IQ ReSTOR非球面多焦点人工晶状体可为患者提供良好的近、中、远全程视力,该人工晶状体具有产生负球差的非球面设计,可平衡角膜的正球差,从而降低了术后总体像差,提高了术眼对比敏感度和眩光敏感度,全面改善患者的视觉质量.  相似文献   

9.
目的: 比较右上方透明角膜切口联合散光矫正型人工晶体(toric intraocular lens,Toric IOL)植入与陡峭轴切口联合非球面人工晶体植入术后残余散光及视觉质量的影响。方法: 纳入2020年1月1日至2021年1月1日在包头医学院第一附属医院眼科门诊就诊,拟行白内障超声乳化吸除术联合IOL植入术的老年性白内障合并低度数角膜散光(散光度为1.0~1.5 D)患者60例(60眼),按不同手术方式分为右上方透明角膜切口联合Toric IOL植入组(试验组)和陡峭轴切口联合非球面IOL植入组(对照组),每组30例(30眼),术后随访3个月。观察患者裸眼视力(uncorrected visual acuity,UCVA)、最佳矫正视力(best corrected visual acuity,BCVA)、残余散光(residual astigmatism,RA)、对比敏感度(contrast sensitivity,CS)和主观视觉质量。结果: 术后均随访3个月。试验组术眼UCVA明显优于对照组(P<0.05);试验组和对照组术后BCVA比较,差异均无统计学意义(P>0.05);试验组和对照组的散光度数均较术前明显降低(P<0.05),且试验组残余散光度数较对照组明显减少(P<0.05);试验组CS在暗光眩光环境下各空间频率(3、6、12、18 cpd)优于对照组(P<0.05);两组CS在明光、明光眩光、暗光环境下各空间频率(3、6、12、18 cpd)对比,差异均无统计学意义(P>0.05);试验组中有眩光视觉干扰症状的患者人数少于对照组(P>0.05)。结论: 两种手术均可有效提高患者的视力及降低术后散光度数,但右上方角膜切口联合Toric IOL植入术可获得更佳的裸眼视力及对比敏感度、更低的残余散光度数和更高的视觉质量,是目前白内障合并低度数角膜散光患者较为有效的治疗方法。  相似文献   

10.
目的:评价白内障超声乳化吸除联合Array多焦点人工晶状体(IOL)植入术后对比敏感度(CS)的变化。方法:为46例(76眼)老年性白内障患者实施超声乳化吸除联合IOL植入术。术前随机将46例患者分为两组,18例(36眼)植入Array SA40Ne多焦点IOL(MIOL);28例(40眼)植入SI40NB单焦点IOL(SIOL)。术后1周、1月应用美国Stereo Optical公司产OPTEC3500视功能测试系统的对比敏感度测试包分别在空间频率为1.5cpd、3cpd、6cpd、12cpd和18cpd的昼及夜照明条件下对手术眼进行有眩光和无眩光的对比敏感度检查。所得数据进行t检验。结果:术后1周,MIOL组在各空间频率下CS普遍低于SIOL组,尤其在昼照明条件下。夜照明条件下,MIOL组在低、高空间频率下的CS均低于SIOL组,差异有统计学意义(P<0.05);昼照明条件下,MIOL组在低、中空间频率下的CS也均低于SIOL组,差异有统计学意义(P<0.01)。术后1月,两组间CS差异减小。除低空间频率下(1.5cpd)MIOL组CS低于SIOL组(P<0.05)外,其他测试状态下两组CS差异均无统计学意义(P>0.05)。结论:植入Array MIOL后对比敏感度降低主要体现在术后短期内(术后1周),该现象将随时间推移而改善。  相似文献   

11.
Background The advent of wavefront technology in the past five years has provided some insight into the optical outcomes of cataract surgery. The Tecnis Z9001 intraocular lens (Tecnis IOL, AMO) with a modified prolate anterior surface was claimed to reduce or even eliminate ocular spherical aberration to improve the visual quality. The purpose of this study was to determine whether Tecnis IOLs can improve the quality of vision as evaluated by measuring visual acuity, wavefront aberration, and contrast sensitivity. Methods In an intraindividual prospective study, 20 patients with bilateral cataract were randomly assigned to receive a modified prolate anterior surface IOL (Tecnis Z9001, AMO) in one eye and a biconvex spherical surface IOL (CeeOn 911A, AMO) in the other. After 3 months, the following were investigated: best corrected visual acuity, pupil diameter, photopic and mesopic contrast sensitivity, and wavefront aberration of the whole eye (ocular), cornea, and internal plane. Results The differences in the best corrected visual acuity and pupil diameter between the two groups were not statistically significant. Negative 4th-order spherical aberration (Z4^0) was found in the Tecnis group, whereas positive Z4^0 found in the CeeOn group for the internal and ocular plane. Statistically significant differences were found at the ocular higher-aberrations between the two IOLs. Contrast sensitivity testing showed significantly better results in the Tecnis group at visual angles higher than 1.0 degree under photopic conditions and at visual angles higher than 1.6 degree under mesopic conditions both without glare and with glare in comparison with the CeeOn group. Conclusions The Tecnis Z9001 IOL with a modified prolate anterior surface produces negative spherical aberration and consequently reduces the higher-order aberrations in pseudophakic eyes. This leads to enhanced contrast sensitivity and improved functional vision compared to conventional spherical IOLs.  相似文献   

12.
袁建树  马蓉  王育文 《现代实用医学》2011,23(12):1330-1331,1336
目的评价Acrysof Toric人工晶状体(IOL)矫正角膜散光的效果及在囊袋内的稳定性。方法收集确诊为年龄相关性白内障并伴有角膜规则散光的患者45例(45眼),采用白内障超声乳化法植人AcrysofToric IOL。观察术前、术后裸眼视力(UCVA)及最佳矫正视力(BCVA)、术前角膜散光、预计残余散光、术后残余散光及IOL旋转度。结果术后3个月92%患眼UCVA≥0.5,78%患眼UCVA≥0.8,BCVA≥0.8者达96%。术前角膜散光平均为(1.400±0.405)D。术后3个月残余散光为(0.197±0.179)D。3个月时与术后第l天轴位相比较,IOL旋转平均为(2.322±1.853)°。结论 Acrysof Toric IOL可使患者获得更好的裸眼远视力,减少了患者的残余散光,预测性强,具有良好的旋转稳定性,是一种有效的矫正角膜规则散光的治疗方法。  相似文献   

13.
[目的]比较2种非球面人工晶状体(IOL)在囊袋内植入后偏心与倾斜的差异,探讨IOL的攀设计与特性对在囊袋内稳定性的影响.[方法]选择行超声乳化白内障摘除联合人工晶状体植入术的老年性白内障患者61例(92只眼),随机分为2组植入L形Acrysof IQ SN60WFIOL(50眼)和一体四点Akreos Adapt AO IOL(42眼).术后6个月用眼前节成像系统Pentacam采集各眼的Scheimpflug图像,分析得出IOL的偏心值与倾斜度.[结果]AcrysofIQSN60WFIOL和AkreosAdaptAOIOL两组患者IOL的水平偏心值分别为(0.21±0.05)mm,(0.17±0.04)mm,相比较差异有统计学意义(P=0.021).两组患者IOL的垂直与水平方向倾斜度分别为1.72°±0.76°,1.51°±0.57°,1.64°±0.71°,1.59°±0.41°,差异均无统计学意义(P=0.674,P=0.521).两组患者的最佳矫正视力和对比敏感度差异亦无统计学意义(P〉0.05).[结论]2种IOL囊袋内植入后在倾斜度方面无明显差异,而在居中性方面,AcrysofIQSN60WFIOL明显优于AkreosAdaptAOIOL,不同非球面IOL的襻设计可影响在囊袋内的稳定性.  相似文献   

14.
廖荣丰  刘晓庆 《安徽医学》2013,34(11):1587-1590
目的比较后房型有晶体眼人工晶体植入术和Lasik术矫正高度近视的效果及术后视觉质量。方法收集在我科行Lasik术和后房型有晶体眼人工晶体植入手术治疗一年的高度近视患者。分为后房型有晶体眼人工晶体植入术组(ICL组,17例,34眼)和Lasik组(21例,35眼),随访1年,观察两组病例术后1年的裸眼视力、最佳矫正视力、眼压、对比敏感度及并发症,比较两组的有效性和安全性。结果Lasik组有效性指数平均值为(93.32±15.69),ICL组为(104.78±18.73),ICL组明显优于Lasik组。Lasik组安全性指数平均值为(100.61±11.62),ICL组为(108.89±17.75),ICL组明显优于Lasik组。Lasik组术后明暗环境下对比敏感度在各个频段均较ICL组低,在白天空间频率段1.5cpd、3cpd、6cpd、12cpd和夜晚1.5cpd、3cpd,差异有统计学意义(P〈0.05)。结论有晶体眼后房型人工晶体植人矫正高度近视术后的安全性指数,有效性指数及对比敏感度优于Lasik组,是一种安全有效的高度近视矫正方法,术后视觉质量优于Lasik。  相似文献   

15.
目的评价年龄相关性白内障超声乳化吸出术后非球面人工晶体植入的视觉质量.方法 60例(60眼)年龄相关性白内障行超声乳化吸出术,30例30眼植入AcrysofIQ非球面人工晶状体,30例30眼植入普通人工晶体SN60NT人工晶体观察术后最佳矫正视力、对比敏感视力、眼内像差.结果术后3个月最佳矫正视力无统计学意义,对比敏感视力、高阶像差两组间差异有统计学意义.结论非球面人工晶体植入术后能够抵消老年人角膜的正球差,从而提高术后视觉质量.  相似文献   

16.
目的 探讨双针导引无缝线巩膜层间固定二期人工晶体(intraocular lens, IOL)植入术的应用价值。方法 回顾性分析于同济大学附属同济医院就诊的由不同原因所致、需行二期IOL植入术的21例(21只眼)的患者资料。采用双针导引无缝线巩膜层间固定二期IOL植入术,术中用两根29G针头分别在距角膜缘后2mm的相对位置做平行角膜缘、长3.6mm的巩膜层间隧道,三片式IOL折叠后注入,晶体襻与针头对接后即可在后者的导引下进入巩膜层间隧道,无需缝线即可完成IOL固定。观察患者手术前后的视力、角膜内皮细胞密度、术中术后并发症及IOL稳定性。结果 术后平均随访(5.5±1.8)个月。术前最佳矫正视力0.50±0.23,术后1个月裸眼视力0.52±0.20,两者间差异无统计学意义(t=1.51,P>0.05)。术后1个月最佳矫正视力为0.62±0.28,较术前升高(t=4.40,P<0.05)。术前角膜内皮细胞密度为(2301±164)个/mm2,术后3个月为(2267±182)个/mm2,两者间差异无统计学意义(t=0.43,P>0.05)。1例术后出现持续性眼压升高。术后无眼内炎、黄斑囊样水肿、视网膜脱离等严重并发症。术后随访期内OCT示各例术眼的IOL位置居中,未出现偏位或倾斜。结论 双针导引无缝线巩膜层间固定二期IOL植入术术式简易,不仅能避免缝线相关并发症,而且能稳定、有效地固定人工晶体,是一种值得推广的手术方法。  相似文献   

17.
Background Multifocal lens has become popular in cataract surgery. Short-term outcome after AcrySof ReSTOR Lens implantation had been reported by many studies, but long-term visual performance and the effect of posterior capsular opacification (PCO) on visual performance need further investigation.
Methods This retrospective study involved 54 eyes from 41 cataract patients implanted with ReSTOR lens, with a follow-up period of 12 to 31 months. Manifest refraction spherical equivalence (MRSE), monocular uncorrected and best-corrected distance visual acuity, uncorrected and distance-corrected near and intermediate visual acuity, contrast sensitivity were assessed. The effect of PCO on visual performance was evaluated by comparing visual parameters between pre and post-capsulotomy.
Results Uncorrected distance visual acuity of eyes with MRSE within ±0.5 diopter (D) was better than those with MRSE greater than ±0.5 D (P 〈0.05). Uncorrected distance and near visual acuity (LogMAR) was 0.10 and 0.17 respectively. Best corrected distance visual acuity and best distance-corrected near visual acuity (LogMAR) was 0.00 and 0.16, a significant improvement was noted after correction (P=0.000, P=-0.001, respectively).
Contrast sensitivity logarithm was comparable with the normal value at difference spatial frequencies except at 12 cpd. In 5 eyes with mild PCO, post-capsulotomy visual parameters were better than pre-capsulotomy (P 〈0.05). Conclusion ReSTOR lens provides a good long-term distance and near vision, functional intermediate vision and contrast sensitivity. Mild PCO significantly affects visual performance and needs early intervention.  相似文献   