首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
目的 探讨彩色超声心动图(TTE)在经胸微创房间隔缺损(ASD)封堵术中的应用价值.方法 对34例ASD患者行经胸微创封堵术,并于术前采用TTE测量各切面ASD长度及周缘情况,术中采用TTE监测封堵过程,术后采用TTE观察心房水平有无残余分流、封堵伞有无脱落及右心系统回缩情况.结果 TTE测量ASD长度为(14.54±7.05)mm,所选封堵器型号大于TTE测量值4~6 mm;33例经胸微创ASD封堵术成功,1例因ASD长度大、一侧无残端组织而无法牢固放置封堵器改开胸手术缝补;术后随访1周、1个月均无残余分流,封堵器封堵牢固、无脱落;右心系统回缩明显.结论 TTE用于经胸微创ASD封堵术能于术前准确测量ASD大小、术中及时监测与引导封堵过程、术后准确观察有无残余分流并评价疗效.  相似文献   

2.
房间隔瘤并发继发孔房间隔缺损的介入治疗评价   总被引:8,自引:0,他引:8       下载免费PDF全文
张玉顺  李寰  代政学  李军  张军 《心脏杂志》2005,17(3):260-262
目的:评价房间隔瘤(ASA)并发继发孔型房间隔缺损(ASD)介入治疗的临床效果。方法:全组21(男8,女13)例,年龄9~56(24士14)岁。经临床、心电图、X线及经胸超声心动图(TTE)检查诊断为ASA并发继发孔型ASD。TTE检查ASA均膨入右心房,测量ASD最大直径12~28(19±7)mm。其中单孔ASD13例,多孔ASD8例,孔间距离1~7mm者7例,12mm者1例。结果:21例均一次封堵成功,技术成功率100%。所用封堵器的直径为16~40(25±8)mm。8例多孔ASD,有7例置入1个封堵器直接封堵多个缺损孔,1例(两个缺损孔之间距离为12mm)分别用18mm和12mm两个封堵器封堵。术后即刻TTE检查显示16例获完全闭合,5例有少或微量残余分流,完全堵闭率76%(16/21)。术后3d复查TTE2例(10%)有微量残余分流。1~6个月复查19例(90%)心脏大小恢复正常,2例(10%)并发心房纤颤患者心脏不同程度的缩小,1例有微量残余分流。1年后随访12例,无封堵器移位及其他并发症。结论:介入治疗房间隔瘤(ASA)并发继发孔型ASD具有操作简便、安全、技术成功率高及封堵效果好等优点。  相似文献   

3.
目的 :评价在经胸超声心动图 (TTE)指导下置入 Am platzer封堵器治疗继发孔型房间隔缺损 (ASD)的可行性和治疗效果。方法 :全组 5 0例 ,年龄 1~ 5 1(18.8土 14.6 )岁 ,术前经 TTE检查示 ASD直径平均为 4~ 33(18.3土 6 .0 ) mm。所有病例均在透视及 TTE监视下经导管置入 Amplatzer封堵器封堵 ASD。术后 3d,1~ 3月分别行经胸超声心动图、心电图及 X线检查评价治疗效果。结果 :5 0例 ASD直径的球囊测量值为 5~ 35 (19.1土 6 .9)mm,选择的封堵器直径为 5~ 36 (2 0 .9土 7.0 ) m m。 5 0例封堵器置入均获得成功 ,技术成功率为 10 0 % ,术中未发生任何重要并发症 ,无急诊手术病例。术后即刻 TTE显示 4例 (8.0 % )存在微量至少量残余分流。术后 3天 TTE显示 2例 (4.0 % )存在微量残余分流。术后 1~ 3月 TTE显示 5 0例 ASD完全闭合。X线检查全部显示肺血减少、右心房、室缩小。结论 :经胸超声心动图指导下经导管置入 Am platzer封堵器治疗 ASD是一种有效、安全、可行的非外科手术方法。我们建议 30 m m以上的 ASD应在经食道超声心动图下监视封堵。  相似文献   

4.
目的:评价房间隔瘤(ASA)并发继发孔型房间隔缺损(ASD)介入封堵术的可行性、安全性和疗效.方法:16例(男4例,女12例),年龄12~66(30.6±14.1)岁.经临床、心电图、X线及经胸超声心动图(TTE)检查诊断为ASA并发继发孔型ASD.TTE检查ASA均膨入右心房, ASD最大直径10~32(17.1±10.4)mm.其中单孔ASD 14例,双孔ASD 2例,孔间距离均小于7 mm.结果:16例均一次封堵成功,成功率100%.所用封堵器的直径为16~42(28.5±6.99)mm.2例双孔ASD中,置入1个封堵器直接封堵2个缺损孔.术中TTE监测检查示15例完全闭合, 1例有少量残余分流.术后3 d复查TTE示均无残余分流;6个月、1年后复查示9例心脏大小恢复正常, 均无残余分流,无封堵器移位及其他并发症.结论:介入封堵治疗ASA并发继发孔型ASD是可行、安全的, 可获得良好的封堵效果.  相似文献   

5.
23例中老年房间隔缺损(ASD)患者,术前经胸超声心动图(TTE)测量房间隔缺损直径为14~34mm,右房、室均不同程度增大,X线胸片示心胸比例0.52~0.70。患者均在局麻下经X线透视和TTE引导行ASD封堵术,均用国产双盘状封堵器一次封堵治疗成功,封堵器直径18~42mm。术后随访1~33个月,未见残余分流、心包填塞及封堵器移位等并发症。  相似文献   

6.
目的 :评价经胸超声心动图 (TTE)在术前测量房间隔缺损 (ASD)大小、术中监测与指导儿童ASD封堵的作用。方法 :10例ASD儿童采用TTE多个切面综合判断ASD大小、周缘情况及房间隔伸展径。比较ASD之TTE测值与封堵成功所选用的封堵器大小之间的关系。在封堵术中TTE监测封堵过程、伞释出后牢固程度及彩色多普勒有无分流。结果 :ASD的TTE测值为 8~ 2 4 (15 .8± 5 .9)mm ,封堵器型号为 8~ 2 8(18.8±6 .0 )mm ,TTE测量的ASD大小与封堵器大小相关良好 ,直线方程Y =4 .36 0 +0 .914X ,相关系数r =0 .90 5(P <0 .0 1)。硬缘ASD的封堵器选择比TTE所测ASD大 1~ 5mm ;封堵器型号的选择多在球囊测值的基础上加 0~ 2mm。所有封堵器牢固 ,无脱落。结论 :TTE封堵术前检查和术中指导ASD封堵器的放置是一种可行、有效、简便的方法  相似文献   

7.
目的:探讨实时三维经食管超声心动图(RT-3D TEE )在监测经胸小切口房间隔缺损(ASD )封堵术的作用。方法初步筛查适合封堵术的ASD患者30例,缺损大小6mm~32mm ,房间隔残缘≥5mm。术前采用经胸超声心动图(TTE)重点测量房间隔总长度、房间隔缺损的最大径、房间隔残缘软边的长度;术中采用RT-3D TEE监测,并测量房间隔总长度、房间隔缺损的最大径、房间隔残缘软边的长度,与术前检查结果进行比较。术后1~12个月进行随访。结果30例经胸小切口ASD封堵术全部成功,没有出现需要进一步处理的意外。经食管超声心动图(TEE )在识别房间隔总长度、软边长度方面均优于TTE ,两者在测量房间隔缺损最大径方面无统计学意义,RT-3D TEE成像显示房间隔缺损立体影像图。结论经胸小切口ASD封堵术中应用经食管超声心动图对于选择合适病例、封堵器型号、指导封堵过程以及疗效评价方面具有重要作用并优于经胸超声心动图,配备实时三维成像功能检查效果更理想。  相似文献   

8.
应用Amplatzer封堵器治疗房间隔缺损疗效评价   总被引:11,自引:6,他引:11       下载免费PDF全文
目的 :评价经导管置入 Amplatzer封堵器治疗继发孔型房间隔缺损 ( ASD)的治疗效果。方法 :全组 67例 ,年龄 2~ 5 9( 2 9土 15 )岁 ,术前经食管超声心动图 ( TEE)检查示 ASD直径 5~ 3 4 ( 2 2土 7) mm。所有病例均在透视及TEE监视下经导管置入 Am platzer封堵器封堵 ASD。 3例有大小紧邻的两个房间隔缺损存在 ,采用较大封堵器 ,一并封堵两个缺损。术后 2 4 h,1~ 3月及 1年分别行经胸超声心动图 ( TTE)、心电图及 X线检查评价治疗效果。结果 :67例 ASD直径的球囊测量值为 7~ 3 6( 2 2土 7) m m,选择的封堵器直径为 7~ 3 8( 2 4土 10 ) m m。 67例封堵器置入后均获得成功 ,技术成功率为 10 0 % ,术中未发生任何重要并发症 ,无急诊手术病例。术后即刻 ,TEE或 TTE显示 7例 ( 10 % )存在微量至少量残余分流。术后 2 4 h TTE显示 4例 ( 6% )存在微量至少量残余分流。术后 1~ 3月TTE示仅 1例 ( 2 % )多发 ASD存在少量分流。X线检查全部显示肺血减少 ,右心房、右心室缩小。结论 :经导管置入 Amplatzer封堵器治疗 ASD是一种有效的非手术方法 ,具有操作简便、安全、技术成功率高及封堵效果好等优点 ,适合于各年龄组继发孔型 ASD的介入治疗  相似文献   

9.
对20例拟诊为继发孔型房间隔缺损(ASD)的患儿,应用封堵器经导管关闭ASD。通过经胸超声心动图(TTE)在术前显示ASD大小及其边缘的解剖特点,术中指导封堵器的放置,术后评价疗效。18例成功实施封堵术者经TTE随访1~22个月,无残余分流征象。  相似文献   

10.
目的:探讨经食道超声心动图(TEE)在成人继发孔房间隔缺损(ASD)介入及外科微创封堵术治疗中的应用价值。方法:以2012年1月至12月间通过经胸壁超声心动图(TTE)及 TEE 筛选的行介入封堵(91例)及外科微创封堵(43例)治疗的134例成人(>15岁)单纯继发孔 ASD 患者为研究对象,介入组患者术中行 TTE 监护,外科微创组患者术中行 TEE 监护。对术前 TTE 和 TEE 相关参数及手术结果进行对照分析。结果:两组患者ASD 缺损径的 TEE 测值均显著大于 TTE 测值(P 均<0.01),最大缺损径的 TEE 测值均显著大于 TTE 测值[(19.8±5.2)mm 比(18.7±4.9)mm],P <0.01;最大缺损径的 TTE 测值与封堵器大小间相关性(介入组 r=0.926,外科微创组 r=0.215)均低于 TEE (介入组 r=0.965,外科微创组 r=0.627),P 均<0.01。结论:经食道超声心动图对房间隔缺损的大小评估优于经胸壁超声心动图,应作为成人房间隔缺损封堵患者术前筛查的常规检查,在外科微创封堵房间隔缺损中作为实时监测引导、即刻评价疗效具有重要价值。  相似文献   

11.
目的:评价在经胸超声心动图(TTE)监测下用Amplatzer封堵器介入治疗房间隔缺损(ASD)的可行性及实用价值。方法:全组共18例继发孔型ASD患者,均在常规C型臂X线机透视和TTE指导下经导管置入Amplatzer封堵器。结果:18例患者中有2例未放置成功而改为开胸手术;16例均成功置入Amplatzer封堵器,即刻完全堵闭,术后随访3个月至2年,TTE示ASD仍被完全封闭,未见残余分流。随访期间无任何并发症。结论:在TTE和X线透视指导下用Amplatzer封堵器治疗继发孔型ASD安全可行,具有一定实用价值。  相似文献   

12.
目的 探讨房间隔缺损(ASD)介入治疗封堵器选择的影响因素.方法 1114例ASD患者,男388例,女726例,年龄2~75(26.3±17.0)岁.按14岁作为儿童与成人的划分点,成人组779例,平均年龄(34.4±13.5)岁;儿童组335例,平均年龄(7.3±3.9)岁.经胸超声心动图测量不同切面缺损大小及边缘长短,根据ASD最大直径选择封堵器,分析不同年龄、缺损形态和边缘大小时,选择封堵器的差别.结果 1114例ASD患者,成功封堵1085例,技术成功率为97.4%.1085例患者中,ASD最大直径为(19.7±7.8)mm,所选择的封堵器直径为(25.8±8.9)mm,封堵器与ASD最大直径差值为(6.1±3.4)mm,封堵器/最大直径为1.3∶1.成人和儿童组ASD大小相近,但成人组封堵器直径、封堵器加大值明显大于儿童组(P<0.05);封堵器/ASD最大直径成人组为1.2~1.8∶1,儿童组为1.1~1.6∶1.随着缺损直径的增大,成人组选择封堵器的加大值亦增加,但非成比例增加.儿童组随着缺损直径的增大,选择封堵器的加大值有增大的趋势,但差异无统计学意义.ASD的最大直径与封堵器的大小显著相关,成人和儿章组其相关系数分别为0.911和0.944(均P<0.01).以ASD最小直径/ASD最大直径的比例来描述缺损的形态,发现随着最小直径与最大直径比值的增大,各组间ASD最大直径或封堵器直径虽无差异,但封堵器加大值明显增大.主动脉侧无缘组选择的封堵器、封堵器加大值明显大于有缘组(均P<0.01).结论 介入治疗ASD,封堵器选择应以测量的ASD最大直径为主体,尚需参考年龄、缺损的形态及其边缘的状况适当增减.  相似文献   

13.
目的探讨经胸彩色多普勒超声心动图(TTE)在房间隔缺损(ASD)经心导管封堵治疗中的应用价值。方法应用TTE选择适于行Amplatzer式封堵术的继发孔型ASD患者27例,在TTE监测引导下经右心导管应用房间隔封堵器关闭ASD。结果26例ASD获成功封堵,术后即刻、1天、1个月和3个月TTE检查显示封堵器位置稳定良好,无残余分流。结论在TTE引导下行ASD封堵术是一种简便、可靠和安全的方法。  相似文献   

14.
Background. During the past 15 years, closure of a secundum atrial septal defect (ASD) has moved from a surgical to a percutaneous transcatheter approach. Few long-term studies of the efficacy and safety of closure of an ASD by an Amplatzer septal occluder (ASO) exist. Methods. To examine the long-term results of secundum ASD closure using the ASO, data on 94 patients who underwent secundum ASD closure with the ASO between 1998 and 2002 were available and reviewed. Data regarding residual shunt, chest pain, palpitations, arrhythmias, headaches, transient ischemic attacks, cerebrovascular accidents, and mortality were collected. Results. Seven (7.4%) subjects had residual shunts immediately following ASO placement. During follow-up, 4 residual shunts closed for a complete closure rate of 97%. Eighteen (19%) patients reported chest pain during the follow-up period. Twenty-three patients (24%) reported palpitations during the follow up period, 7 were documented arrhythmias, including supraventricular tachycardia, atrial fibrillation, and premature ventricular beats. Migraine headaches were new-onset in 4 patients. Migraine cessation occurred in 2 patients after secundum ASD closure. One child died from a cerebral vascular event 18 months following device placement. Only 1 patient developed mild aortic insufficiency. Conclusion. These data indicate that for up to 120 months of patient follow-up, the ASO continues to be a safe device. Residual shunts and arrhythmias have low incidence post-ASO placement. Given the mortality in one high-risk patient, further investigation into anti-platelet therapy after device placement is warranted.  相似文献   

15.
目的探讨经导管植入封堵器治疗小儿多发房间隔缺损的可行性,并对其短期疗效进行初步评价。方法44例经胸超声心动图检查确诊多发房间隔缺损的患儿[男14例,女30例,年龄4(2~14)岁]于X线和经胸超声心动图监测下植入房间隔缺封堵器,术后复查经胸心脏超声心动图、心电图及X线胸片评估初步疗效,并通过随访分析评估短期疗效。结果44例患儿中,39例为2孔房间隔缺损,5例为3孔房间隔缺损。大缺损直径为(13.0±4.7)mm,小缺损直径为(5.4±2.3)mm;缺损之间间隔长(5.1±2.4)mm;所选择封堵器大小为(17.7±5.7)mm。44例均根据经胸超声心动图测量结果选择封堵器,5例植入2个封堵器,余39例植入一个封堵器,采用封堵器直径为(22±7)mm。封堵器植入均成功,在术中、术后及随访中所有患儿均无严重并发症。随访时间3个月~1年,所有患者的封堵器位置良好,心电图检查均未见心律失常发生。右心房舒张末期内径由术前的(29.2±5.8)mm降至术后6个月的(25.6±4.3)mm,差异有统计学意义(P<0.05);右心室舒张末期内径由术前的(28.2±5.7)mm降至术后6个月的(24.78±5.33)mm,差异有统计学意义(P<0.05)。术后即刻及24 h复查经胸超声心动图有6例(13.6%,6/44)少量残余分流和10例(22.7%,10/44)有中量残余分流,1例(2.3%,1/44)(5 mm)大量残余分流,成功率为75%(33/44)。6个月随访有3例(6.8%,3/44)患儿存在少量残余分流,6例(13.6%,6/44)存在中量残余分流,1例(2.3%,1/44)(4.1 mm)存在大量残余分流,封堵成功率为84.1%(37/44)。一年随访时有2例(6%,2/33)患儿存在少量残余分流,2例(6%,2/33)存在中量残余分流(n=33),封堵成功率94%(31/33)。结论经导管治疗多发房间隔缺损是安全的,疗效显著。在短期随访中右心室及右心房舒张末内径显著缩小。  相似文献   

16.
经静脉闭合房间隔缺损的疗效观察   总被引:4,自引:0,他引:4  
目的 :评价经静脉置入 Amplatzer封堵器治疗继发孔型房间隔缺损 (ASD)的疗效。方法 :2 4例患者术前经多普勒超声心动图检查 ASD直径为 6~ 30 (18.96± 7.0 3) m m。在透视及经超声心动图引导下经静脉置入Am platzer封堵器闭合 ASD。结果 :2 4例 ASD直径的球囊测量值为 15~ 36 (2 6 .2 5± 7.5 7) mm ,选择的封堵器直径为 14~ 36 (2 6 .5 2± 7.15 ) m m。 2 4例封堵器置入均获得成功 ,术中无并发症 ,1例在术后第 3天出现 度 型房室传导阻滞 ,2周后恢复。 7例术后即刻超声检查显示微量残余分流 ,术后 1周复查均无分流。结论 :经静脉置入 Amplatzer封堵器治疗 ASD是一种有效的非外科手术方法。  相似文献   

17.
介入治疗先天性心脏病118例近期疗效评价   总被引:2,自引:4,他引:2  
目的:评价应用国产封堵器治疗动脉导管未闭(PDA)、房间隔缺损(ASD)室间隔缺损(VSD)的近期疗效及安全性。方法:118例先天性心脏病患者(PDA24例,ASD48例,VSD46例)均在X线透视及经胸超声心动图监视下经导管置入封堵器治疗PDA、ASD和VSD。结果:全组封堵成功率98.3%,所有封堵成功的患者均于术后24h、7d、1月和3月行经胸超声心动图检查,均无残余分流。结论:经导管置入封堵器是治疗PDA、ASD和VSD的一种操作简便、成功率高、疗效可靠的介入方法。  相似文献   

18.
Amplatzer封堵器经导管治疗多孔房间隔缺损   总被引:6,自引:2,他引:6       下载免费PDF全文
目的 :探讨 Amplatzer封堵器经导管治疗多孔房间隔缺损的临床应用价值。方法 :全组患者 6(男 2 ,女 4)例 ,年龄 4~ 5 0岁 ,经 TTE或 TEE检查诊断为多孔房间隔缺损。均在 X线和 TTE或 TEE监测下经导管行 Amplatzer封堵器治疗。术后重复 TTE或 TEE、ECG及 X线平片检查以评价疗效。结果 :全组 6例患者 Amplatzer封堵器置入均获成功 ,术中无重要并发症发生。其中置入 1个封堵器的患者 5例 ,置入 2个封堵器的患者 1例。术后即刻TTE或 TEE检查 5例无残余分流 ,1例小缺损孔有少量残余分流 ,随访 1年中少量残余分流仍存在。1例肺动脉压中度增高患者 ,术后 3 0 min测量肺动脉压下降 >2 0 mm Hg。随访期间所有患者封堵器位置形态良好 ,未发现封堵器的变形 ,移位以及金属结构断裂等改变 ;右房 ,右室有不同程度的缩小 ,X线平片显示肺血有不同程度减少 ;术后ECG检查均未见心律失常发生。结论 :Amplatzer封堵器经导管治疗多孔房间隔缺损是安全有效的。对于相隔距离较近的多孔房间隔缺损 ,可采用单个封堵器封堵 ;而相隔距离较远的缺损 ,可采用同时置入两个封堵器  相似文献   

19.
经导管封堵成人多孔型房间隔缺损的体会   总被引:4,自引:0,他引:4  
目的:通过对多孔型房间隔缺损(ASD)进行经导管封堵治疗,探讨多孔型ASD介入治疗的适应证及注意事项。 方法:先经心脏超声检查确诊为多孔型ASD,后在局部麻醉下用测量球囊进行试封堵,同时用心脏超声检测试封堵时两ASD闭合情况及孔间距,并确定置入封堵器数量及大小,术后用心脏超声进行随访观察。 结果:全组6例双孔型ASD患者中2例分别置入2个封堵器,4例置入1个封堵器。术后随访1个月至2年,4例无残余分流,1例随访2年虽仍有少许残余分流,但自觉症状好转,心影缩小。另1例术后1个月因残余分流而被迫手术取出。 结论:经导管封堵成人多孔型ASD安全、有效,对两ASD相距较远者应放置2个封堵器,对两ASD相距较近者则可用1个封堵器封堵。  相似文献   

20.
BACKGROUND: Our purpose was to determine the role of transesophageal echocardiography (TEE) in the closure of atrial septal defects by the Amplatzer septal occluder (ASO) (AGA Medical, Golden Valley, Minn). METHODS: A total of 240 patients with atrial septal defect (ASD) secundum were examined by transthoracic 2-dimensional echocardiography (TTE) and TEE to determine the ASD morphologic features, diameter, and rims. During transcatheter closure TEE was used for determination of the ASD diameter and guidance of the ASO implantation. RESULTS: Sixteen (6%) patients were found not suitable for transcatheter closure with TTE, 35 (14%) with TEE, and 2 during catheterization. Twenty-eight patients (18%) had partial or total deficiency of the posterior, inferoanterior, or inferoposterior rim, 54 (27%) had a centrally positioned ASD, 92 (46%) had insufficient superoanterior rim, and 9 had multiple ASDs, whereas 8 had a septal aneurysm associated with a single defect and 4 a multiperforated aneurysm. A total of 170 patients underwent implantation of ASO. The ASO was correctly positioned in 144 at the first attempt. In the remainder TEE revealed unstable position of the left atrial disk (12), opening of both atrial disks in the left atrium (5), deployment of the device through the smaller defect in patients with multiple ASDs (3), and, in 1 patient, the device was too small and had to be replaced by a larger one. CONCLUSIONS: Morphologic variations of the ASD are common. TEE is crucial for the determination of the ASD morphologic features, diameter, and rims, which are crucial for proper patient selection. TEE allows precise guiding and positioning of the ASO, which is essential for safe and effective transcatheter ASD closure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号