1.
The anterior cruciate ligament (ACL) can be anatomically divided into anteromedial (AM) and posterolateral (PL) bundles. Current ACL reconstruction techniques focus primarily on reproducing the AM bundle, but are insufficient in response to rotatory loads. The objective of this study was to determine the distribution of in situ force between the two bundles when the knee is subjected to anterior tibial and rotatory loads. Ten cadaveric knees (50+/-10 years) were tested using a robotic/universal force-moment sensor (UFS) testing system. Two external loading conditions were applied: a 134 N anterior tibial load at full knee extension and 15 degrees, 30 degrees, 60 degrees, and 90 degrees of flexion and a combined rotatory load of 10 Nm valgus and 5 Nm internal tibial torque at 15 degrees and 30 degrees of flexion. The resulting 6 degrees of freedom kinematics of the knee and the in situ forces in the ACL and its two bundles were determined. Under an anterior tibial load, the in situ force in the PL bundle was the highest at full extension (67+/-30 N) and decreased with increasing flexion. The in situ force in the AM bundle was lower than in the PL bundle at full extension, but increased with increasing flexion, reaching a maximum (90+/-17 N) at 60 degrees of flexion and then decreasing at 90 degrees. Under a combined rotatory load, the in situ force of the PL bundle was higher at 15 degrees (21+/-11 N) and lower at 30 degrees of flexion (14+/-6 N). The in situ force in the AM bundle was similar at 15 degrees and 30 degrees of knee flexion (30+/-15 vs. 35+/-16 N, respectively). Comparing these two external loading conditions demonstrated the importance of the PL bundle, especially when the knee is near full extension. These findings provide a better understanding of the function of the two bundles of the ACL and could serve as a basis for future considerations of surgical reconstruction in the replacement of the ACL.  相似文献   

2.
Application of axial tibial force to the knee at a fixed flexion angle has been shown to generate ACL force. However, direct measurements of ACL force under an applied axial tibial force have not been reported during a passive flexion–extension cycle. We hypothesized that ACL forces and knee kinematics during knee extension would be significantly different than those during knee flexion, and that ACL removal would significantly increase all kinematic measurements. A 500 N axial tibial force was applied to intact knees during knee flexion–extension between 0° and 50°. Contact force on the sloping lateral tibial plateau produced a coupled internal + valgus rotation of the tibia, anterior tibial displacement, and elevated ACL forces. ACL forces during knee extension were significantly greater than those during knee flexion between 5° and 50°. During knee extension, ACL removal significantly increased anterior tibial displacement between 0° and 50°, valgus rotation between 5° and 50°, and internal tibial rotation between 5° and 15°. With the ACL removed, kinematic measurements during knee extension were significantly greater than those during knee flexion between 5° and 45°. The direction of knee flexion–extension movement is an important variable in determining ACL forces and knee kinematics produced by axial tibial force. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 32:89–95, 2014.  相似文献   

3.
The optimal treatment for the MCL in the combined ACL and MCL-injured knee is still controversial. Therefore, we designed this study to examine the mechanical interaction between the ACL graft and the MCL in a goat model using a robotic/universal force-moment sensor testing system. The kinematics of intact, ACL-deficient, ACL-reconstructed, and ACL-reconstructed/MCL-deficient knees, as well as the in situ forces in the ACL, ACL graft, and MCL were determined in response to two external loading conditions: 1) anterior tibial load of 67 N and 2) valgus moment of 5 N-m. With an anterior tibial load, anterior tibial translation in the ACL-deficient knee significantly increased from 2.0 and 2.2 mm to 15.7 and 18.1 mm at 30° and 60° of knee flexion, respectively. The in situ forces in the MCL also increased from 8 to 27 N at 60° of knee flexion. ACL reconstruction reduced the anterior tibial translation to within 2 mm of the intact knee and significantly reduced the in situ force in the MCL to 17 N. However, in response to a valgus moment, the in situ forces in the ACL graft increased significantly by 34 N after transecting the MCL. These findings show that ACL deficiency can increase the in situ forces in the MCL while ACL reconstruction can reduce the in situ forces in the MCL in response to an anterior tibial load. On the other hand, the ACL graft is subjected to significantly higher in situ forces with MCL deficiency during an applied valgus moment. Therefore, the ACL-reconstructed knee with a combined ACL and MCL injury should be protected from high valgus moments during early healing to avoid excessive loading on the graft.  相似文献   

4.
The anterior cruciate ligament has a complex fiber anatomy and is not considered to be a uniform structure. Current anterior cruciate ligament reconstructions succeed in stabilizing the knee, but they neither fully restore normal knee kinematics nor reproduce normal ligament, function. To improve the outcome of the reconstruction, it may be necessary to reproduce the complex function of the intact anterior cruciate ligament in the replacement graft. We examined the in situ forces in nine human anterior cruciate ligaments as well as the force distribution between the anteromedial and posterolateral bundles of the ligament in response to applied anterioi tibial loads ranging from 22 to 110 N at knee flexion angles of 0–90°. The analysis was performed using a robotic manipulator in conjunction with a universal force-moment sensor. The in situ forces were determined with no device attached to the ligament, while the knee was permitted to move freely in response to the applied loads. We found that the in situ forces in the anterior cruciate ligament ranged from 12.8 ± 7.3 N under 22 N of anterior tibial load applied at 90° of knee flexion to 110.6 ± 14.8 N under 110 N of applied load at 15° of flexion. The magnitude of the in situ force in the posterolateral bundle was larger than that in the anteromedial bundle at knee flexion angles between 0 and 45°, reaching a maximum of 75.2 ± 18.3 N at 15° of knee flexion under an anterior tibial load of 110 N. The magnitude of the in situ force in the posterolateral bundle was significantly affected by knee flexion angle and anterior tibial load in a fashion remarkably similar to that seen in the anterior cruciate ligament. The magnitude of the in situ force in the anteromedial bundle, in contrast, remained relatively constant, not changing with flexion angle. Significant differences in the direction of the in situ force between the anteromedial bundle and the posterolateral bundle were found only at flexion angles of 0 and 60° and only under applied anterior tibial loads greater than 66 N. We have demonstrated the nonuniformity of the anterior cruciate ligament under unconstrained anterior tibial loads. Our data further suggest that in order for the anterior cruciate ligament replacement graft to reproduce the in situ forces of the normal anterior cruciate ligament, reconstruction techniques should take into account the role of the posterolateral bundle in addition to that of the anteromedial bundle.  相似文献   

5.
6.
《Acta orthopaedica》2013,84(2):267-274
Background?Long-term follow-up studies have indi-cated that there is an increased incidence of arthrosis following anterior cruciate ligament (ACL) reconstruc-tion, suggesting that the reconstruction may not repro-duce intact ACL biomechanics. We studied not only the magnitude but also the orientation of the ACL and ACL graft forces

Methods?10 knee specimens were tested on a robotic testing system with the ACL intact, deficient, and recon-structed (using a bone-patella tendon-bone graft). The magnitude and orientation of the ACL and ACL graft forces were determined under an anterior tibial load of 130?N at full extension, and 15, 30, 60, and 90° of flexion. Orientation was described using elevation angle (the angle formed with the tibial plateau in the sagit-tal plane) and deviation angle (the angle formed with respect to the anteroposterior direction in the transverse plane)

Results?ACL reconstruction restored anterior tibial translation to within 2.6?mm of that of the intact knee under the 130-N anterior load. Average internal tibial rotation was reduced after ACL reconstruction at all flexion angles. The force vector of the ACL graft was significantly different from the ACL force vector. The average values of the elevation and deviation angles of the ACL graft forces were higher than that of the intact ACL at all flexion angles

Interpretation?Contemporary single bundle ACL reconstruction restores anterior tibial translation under anterior tibial load with different forces (both magni-tude and orientation) in the graft compared to the intact ACL. Such graft function might alter knee kinematics in other degrees of freedom and could overly constrain the tibial rotation. An anatomic ACL reconstruction should reproduce the magnitude and orientation of the intact ACL force vector, so that the 6-degrees-of-freedom knee kinematics and joint reaction forces can be restored.  相似文献   

7.
The two functional bundles of the anterior cruciate ligament (ACL), namely, the anteromedial (AM) and posterolateral (PL) bundles, must work in concert to control displacement of the tibia relative to the femur for complex motions. Thus, the replacement graft(s) for a torn ACL should possess similar tension patterns. The objective of the study was to examine whether a double‐bundle ACL reconstruction with the semitendinosus‐gracilis autografts could replicate the tension patterns of those for the intact ACL under controlled in vitro loading conditions. By means of a robotic/universal force moment sensor (UFS) testing system, the in situ force vectors (both magnitude and direction) for the AM and PL bundles of the ACL, as well as their respective replacement grafts, were determined and compared on nine human cadaveric knees. It was found that double‐bundle ACL reconstruction could closely replicate the in situ force vectors. Under a 134‐N anterior tibial load, the resultant force vectors for the intact ACL and the reconstructed ACL had a difference of 5 to 11 N (p > 0.05) in magnitude and 1 to 13° (p > 0.05) in direction. Whereas, under combined rotatory loads of 10‐N‐m valgus and 5‐N‐m internal tibial torques, the corresponding differences were 10 to 16 N and 4° to 11°, respectively. Again, there were no statistically significant differences except at 30° of flexion where the force vector for the AM graft had a 15° (p < 0.05) lower elevation angle than did the AM bundle. © 2008 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 27: 879–884, 2009  相似文献   

8.
Background Long-term follow-up studies have indi-cated that there is an increased incidence of arthrosis following anterior cruciate ligament (ACL) reconstruc-tion, suggesting that the reconstruction may not repro-duce intact ACL biomechanics. We studied not only the magnitude but also the orientation of the ACL and ACL graft forces

Methods 10 knee specimens were tested on a robotic testing system with the ACL intact, deficient, and recon-structed (using a bone-patella tendon-bone graft). The magnitude and orientation of the ACL and ACL graft forces were determined under an anterior tibial load of 130 N at full extension, and 15, 30, 60, and 90° of flexion. Orientation was described using elevation angle (the angle formed with the tibial plateau in the sagit-tal plane) and deviation angle (the angle formed with respect to the anteroposterior direction in the transverse plane)

Results ACL reconstruction restored anterior tibial translation to within 2.6 mm of that of the intact knee under the 130-N anterior load. Average internal tibial rotation was reduced after ACL reconstruction at all flexion angles. The force vector of the ACL graft was significantly different from the ACL force vector. The average values of the elevation and deviation angles of the ACL graft forces were higher than that of the intact ACL at all flexion angles

Interpretation Contemporary single bundle ACL reconstruction restores anterior tibial translation under anterior tibial load with different forces (both magni-tude and orientation) in the graft compared to the intact ACL. Such graft function might alter knee kinematics in other degrees of freedom and could overly constrain the tibial rotation. An anatomic ACL reconstruction should reproduce the magnitude and orientation of the intact ACL force vector, so that the 6-degrees-of-freedom knee kinematics and joint reaction forces can be restored.  相似文献   

9.
《Arthroscopy》2003,19(3):297-304
Purpose: To study how well an anterior cruciate ligament (ACL) graft fixed at the 10 and 11 o'clock positions can restore knee function in response to both externally applied anterior tibial and combined rotatory loads by comparing the biomechanical results with each other and with the intact knee. Type of Study: Biomechanical experiment using human cadaveric specimens. Methods: Ten human cadaveric knees (age, 41±13 years) were reconstructed by placing a bone–patellar tendon–bone graft at the 10 and 11 o'clock positions, in a randomized order, and then tested using a robotic/universal force-moment sensor testing system. Two external loading conditions were applied: (1) 134 N anterior tibial load with the knee at full extension, 15°, 30°, 60°, and 90° of flexion, and (2) a combined rotatory load of 10 N-m valgus and 5 N-m internal tibial torque with the knee at 15° and 30° of flexion. The resulting kinematics of the reconstructed knee and in situ forces in the ACL graft were determined for each femoral tunnel position. Results: In response to a 134-N anterior tibial load, anterior tibial translation (ATT) for both femoral tunnel positions was not significantly different from the intact knee except at 90° of knee flexion as well as at 60° of knee flexion for the 10 o'clock position. There was no significant difference in the ATT between the 10 and 11 o'clock positions, except at 90° of knee flexion. Under a combined rotatory load, however, the coupled ATT for the 11 o'clock position was approximately 130% of that for the intact knee at 15° and 30° of flexion. For the 10 o'clock position, the coupled ATT was not significantly different from the intact knee at 15° of flexion and approximately 120% of that for the intact knee at 30° of flexion. Coupled ATT for the 10 o'clock position was significantly smaller than for the 11 o'clock position at 15° and 30° of flexion. The in situ force in the ACL graft was also significantly higher for the 10 o'clock position than the 11 o'clock position at 30° of flexion in response to the same loading condition (70 ± 18 N v 60 ± 15 N, respectively). Conclusions: The 10 o'clock position more effectively resists rotatory loads when compared with the 11 o'clock position as evidenced by smaller ATT and higher in situ force in the graft. Despite the fact that ACL grafts placed at the 10 or 11 o'clock positions are equally effective under an anterior tibial load, neither femoral tunnel position was able to fully restore knee stability to the level of the intact knee.Arthroscopy: The Journal of Arthroscopic and Related Surgery, Vol 19, No 3 (March), 2003: pp 297–304  相似文献   

10.
The optimal treatment for the MCL in the combined ACL and MCL-injured knee is still controversial. Therefore, we designed this study to examine the mechanical interaction between the ACL graft and the MCL in a goat model using a robotic/universal force-moment sensor testing system. The kinematics of intact, ACL-deficient, ACL-reconstructed, and ACL-reconstructed/ MCL-deficient knees, as well as the in situ forces in the ACL, ACL graft, and MCL were determined in response to two external loading conditions: 1) anterior tibial load of 67 N and 2) valgus moment of 5 N-m. With an anterior tibial load, anterior tibial translation in the ACL-deficient knee significantly increased from 2.0 and 2.2 mm to 15.7 and 18.1 mm at 30 degrees and 60 degrees of knee flexion, respectively. The in situ forces in the MCL also increased from 8 to 27 N at 60 degrees of knee flexion. ACL reconstruction reduced the anterior tibial translation to within 2 mm of the intact knee and significantly reduced the in situ force in the MCL to 17 N. However, in response to a valgus moment, the in situ forces in the ACL graft increased significantly by 34 N after transecting the MCL. These findings show that ACL deficiency can increase the in situ forces in the MCL while ACL reconstruction can reduce the in situ forces in the MCL in response to an anterior tibial load. On the other hand, the ACL graft is subjected to significantly higher in situ forces with MCL deficiency during an applied valgus moment. Therefore, the ACL-reconstructed knee with a combined ACL and MCL injury should be protected from high valgus moments during early healing to avoid excessive loading on the graft.  相似文献   

11.
The optimal treatment for the MCL in the combined ACL and MCL-injured knee is still controversial. Therefore, we designed this study to examine the mechanical interaction between the ACL graft and the MCL in a goat model using a robotic/universal force-moment sensor testing system. The kinematics of intact, ACL-deficient, ACL-reconstructed, and ACL-reconstructed/MCL-deficient knees, as well as the in situ forces in the ACL, ACL graft, and MCL were determined in response to two external loading conditions: 1) anterior tibial load of 67 N and 2) valgus moment of 5 N-m. With an anterior tibial load, anterior tibial translation in the ACL-deficient knee significantly increased from 2.0 and 2.2 mm to 15.7 and 18.1 mm at 30° and 60° of knee flexion, respectively. The in situ forces in the MCL also increased from 8 to 27 N at 60° of knee flexion. ACL reconstruction reduced the anterior tibial translation to within 2 mm of the intact knee and significantly reduced the in situ force in the MCL to 17 N. However, in response to a valgus moment, the in situ forces in the ACL graft increased significantly by 34 N after transecting the MCL. These findings show that ACL deficiency can increase the in situ forces in the MCL while ACL reconstruction can reduce the in situ forces in the MCL in response to an anterior tibial load. On the other hand, the ACL graft is subjected to significantly higher in situ forces with MCL deficiency during an applied valgus moment. Therefore, the ACL-reconstructed knee with a combined ACL and MCL injury should be protected from high valgus moments during early healing to avoid excessive loading on the graft.  相似文献   

12.
A noncontact, kinematic method was used to determine the lengths and in situ loads borne by portions of the human anterior cruciate ligament (ACL) by the combination of kinematic data from the intact knee and load-length curves of the isolated ACL. Specimens from knees of cadavers of young people were tested in passive flexion and extension as well as with 100 N of anterior tibial drawer at 0, 30, 45, and 90° of flexion. The results showed that the in situ load on the whole ACL (as much as 129 N) can exceed the magnitude of the applied anterior tibial drawer. The load distribution within the ligament changes with flexion of the knee. The anterior and posterior portions share the anterior drawer force equally toward full extension. However, at flexion >45°, the anterior portion supports 90–95% of the load. This information is important for the determination of the function of the entire ACL and of its subportions in response to external loading of the intact knee. In particular, the preferential loading found for one of the portions of the ACL demonstrates that successful operative reconstruction of this ligament may not be achieved simply by reproduction of its gross anatomy; consideration of the role of the ligament in the overall kinematics of the knee is necessary.  相似文献   

13.
《Arthroscopy》2000,16(6):633-639
Purpose: Although it is well known that the anterior cruciate ligament (ACL) is a primary restraint of the knee under anterior tibial load, the role of the ACL in resisting internal tibial torque and the pivot shift test is controversial. The objective of this study was to determine the effect of these 2 external loading conditions on the kinematics of the intact and ACL-deficient knee and the in situ force in the ACL. Type of Study: This study was a biomechanical study that used cadaveric knees with the intact knee of the specimen serving as a control. Materials and Methods: Twelve human cadaveric knees were tested using a robotic/universal force-moment sensor testing system. This system applied (1) a 10–Newton meter (Nm) internal tibial torque and (2) a combined 10-Nm valgus and 10-Nm internal tibial torque (simulated pivot shift test) to the intact and the ACL-deficient knee. Results: In the ACL-deficient knee, the isolated internal tibial torque significantly increased coupled anterior tibial translation over that of the intact knee by 94%, 48%, and 19% at full extension, 15°, and 30° of flexion, respectively (P <.05). In the case of the simulated pivot shift test, there were similar increases in anterior tibial translation, i.e., 103%, 61%, and 32%, respectively (P <.05). Furthermore, the anterior tibial translation under the simulated pivot shift test was significantly greater than under an isolated internal tibial torque (P <.05). Under the simulated pivot shift test, the in situ forces in the ACL were 83 ± 16 N at full extension and 93 ± 23 N at 15° of knee flexion. These forces were also significantly higher when compared with those for an isolated internal tibial torque (P <.05). Conclusion: Our data indicate that the ACL plays an important role in restraining coupled anterior tibial translation in response to the simulated pivot shift test as well as under an isolated internal tibial torque, especially when the knee is near extension. These findings are also consistent with the clinical observation of anterior tibial subluxation during the pivot shift test with the knee near extension.Arthroscopy: The Journal of Arthroscopic and Related surgery, Vol 16, No 6 (September), 2000: pp 633–639  相似文献   

14.
Introduction  Recently, several publications investigated the rotational instability of the human knee joint under pivot shift examinations and reported the internal tibial rotation as measurement for instrumented knee laxity measurements. We hypothesize that ACL deficiency leads to increased internal tibial rotation under a simulated pivot shift test. Furthermore, it was hypothesized that anatomic single bundle ACL reconstruction significantly reduces the internal tibial rotation under a simulated pivot shift test when compared to the ACL-deficient knee. Methods  In seven human cadaveric knees, the kinematics of the intact knee, ACL-deficient knee, and anatomic single bundle ACL reconstructed knee were determined in response to a 134 N anterior tibial load and a combined rotatory load of 10 N m valgus and 4 N m internal tibial rotation using a robotic/UFS testing system. Statistical analyses were performed using a two-way ANOVA test. Results  Single bundle ACL reconstruction reduced the anterior tibial translation under a simulated KT-1000 test significantly compared to the ACL-deficient knee (P < 0.05). After reconstruction, there was a statistical significant difference to the intact knee at 30° of knee flexion. Under a simulated pivot shift test, anatomic single bundle ACL reconstruction could restore the intact knee kinematics. Internal tibial rotation under a simulated pivot shift showed no significant difference in the ACL-intact, ACL-deficient and ACL-reconstructed knee. Conclusion  In conclusion, ACL deficiency does not increase the internal tibial rotation under a simulated pivot shift test. For objective measurements of the rotational instability of the knee using instrumented knee laxity devices under pivot shift mechanisms, the anterior tibial translation should be rather evaluated than the internal tibial rotation. This study was supported in part by a grant of the German Speaking Association of Arthroscopy (AGA).  相似文献   

15.
The anterior cruciate ligament (ACL) is the major contributor to limit excessive anterior tibial translation (ATT) when the knee is subjected to an anterior tibial load. However, the importance of the medial and lateral structures of the knee can also play a significant role in resisting anterior tibial loads, especially in the event of an ACL injury. Therefore, the objective of this study was to determine quantitatively the increase in the in-situ forces in the medial collateral ligament (MCL) and posterolateral structures (PLS) of the knee associated with ACL deficiency. Eight fresh-frozen cadaveric human knees were subjected to a 134-N anterior tibial load at full extension and at 15°, 30°, 60°, and 90° of knee flexion. The resulting 5 degrees of freedom kinematics were measured for the intact and the ACL-deficient knees. A robotic/universal force-moment sensor testing system was used for this purpose, as well as to determine the in-situ force in the MCL and PLS in the intact and ACL-deficient knees. For the intact knee, the in-situ forces in both the MCL and PLS were less than 20 N for all five flexion angles tested. But in the ACL-deficient knee, the in-situ forces in the MCL and PLS, respectively, were approximately two and five times as large as those in the intact knee (P < 0.05). The results of this study demonstrate that, although both the MCL and PLS play only a minor role in resisting anterior tibial loads in the intact knee, they become significant after ACL injury. Received: December 3, 1999 / Accepted: July 19, 2000  相似文献   

16.
A bioresorbable, mono‐crystalline magnesium (Mg) ring device and suture implantation technique were designed to connect the ends of a transected anterior cruciate ligament (ACL) to restabilize the knee and load the ACL to prevent disuse atrophy of its insertion sites and facilitate its healing. To test its application, cadaveric goat stifle joints were evaluated using a robotic/universal force‐moment sensor testing system in three states: Intact, ACL‐deficient, and after Mg ring repair, at 30°, 60°, and 90° of joint flexion. Under a 67‐N anterior tibial load simulating that used in clinical examinations, the corresponding anterior tibial translation (ATT) and in‐situ forces in the ACL and medial meniscus for 0 and 100 N of axial compression were obtained and compared with a control group treated with suture repair. In all cases, Mg ring repair reduced the ATT by over 50% compared to the ACL‐deficient joint, and in‐situ forces in the ACL and medial meniscus were restored to near normal levels, showing significant improvement over suture repair. These findings suggest that Mg ring repair could successfully stabilize the joint and load the ACL immediately after surgery, laying the framework for future in vivo studies to assess its utility for ACL healing. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:2001–2008, 2016.  相似文献   

17.
The purpose of this study was to evaluate the effect of the iliotibial band (ITB) on the kinematics of anterior cruciate ligament (ACL) intact and deficient knees and also on the in situ force in the ACL during a simulated pivot shift test. A combination of 10 N-m valgus and 5 N-m internal tibial torques was applied to 10 human cadaveric knees at 15 degrees, 30 degrees, 45 degrees, and 60 degrees of flexion using a robotic/universal force-moment sensor testing system. ITB forces of 0, 22, 44, and 88 N were also applied. An 88 N ITB force significantly decreased coupled anterior tibial translation of ACL deficient knees by 32%-45% at high flexion angles, but did not have a significant effect at low flexion angles. Further, an 88 N ITB force significantly decreased in situ forces in the ACL at all flexion angles by 23%-40%. These results indicate that during the pivot shift test, the ITB can improve tibial reduction at high flexion angles while not affecting subluxation at low flexion angles. Additionally, the action of the ITB as an ACL agonist suggests that its use as an ACL graft might hinder knee stability in response to rotatory load.  相似文献   

18.
Anterior cruciate ligament (ACL) injuries most frequently occur under the large loads associated with a unipedal jump landing involving a cutting or pivoting maneuver. We tested the hypotheses that internal tibial torque would increase the anteromedial (AM) bundle ACL relative strain and strain rate more than would the corresponding external tibial torque under the large impulsive loads associated with such landing maneuvers. Twelve cadaveric female knees [mean (SD) age: 65.0 (10.5) years] were tested. Pretensioned quadriceps, hamstring, and gastrocnemius muscle‐tendon unit forces maintained an initial knee flexion angle of 15°. A compound impulsive test load (compression, flexion moment, and internal or external tibial torque) was applied to the distal tibia while recording the 3D knee loads and tibofemoral kinematics. AM‐ACL relative strain was measured using a 3 mm DVRT. In this repeated measures experiment, the Wilcoxon signed‐rank test was used to test the null hypotheses with p < 0.05 considered significant. The mean (±SD) peak AM‐ACL relative strains were 5.4 ± 3.7% and 3.1 ± 2.8% under internal and external tibial torque, respectively. The corresponding mean (± SD) peak AM‐ACL strain rates reached 254.4 ± 160.1%/s and 179.4 ± 109.9%/s, respectively. The hypotheses were supported in that the normalized mean peak AM‐ACL relative strain and strain rate were 70 and 42% greater under internal than under external tibial torque, respectively (p = 0.023, p = 0.041). We conclude that internal tibial torque is a potent stressor of the ACL because it induces a considerably (70%) larger peak strain in the AM‐ACL than does a corresponding external tibial torque. © 2011 Orthopaedic Research Society. © 2011 Orthopaedic Research Society Published by Wiley Periodicals, Inc. J Orthop Res 30:528–534, 2012  相似文献   

19.
Medial unicompartmental knee arthroplasty (UKA) is an accepted treatment for isolated medial osteoarthritis. However, using an improper thickness for the tibial component may contribute to early failure of the prosthesis or disease progression in the unreplaced lateral compartment. Little is known of the effect of insert thickness on both knee kinematics and ligament forces. Therefore, a computational model of the tibiofemoral joint was used to determine how non‐conforming, fixed bearing medial UKA affects tibiofemoral kinematics, and tension in the medial collateral ligament (MCL) and the anterior cruciate ligament (ACL) during passive knee flexion. Fixed bearing medial UKA could not maintain the medial pivoting that occurred in the intact knee from 0° to 30° of passive flexion. Abnormal anterior–posterior (AP) translations of the femoral condyles relative to the tibia delayed coupled internal tibial rotation, which occurred in the intact knee from 0° to 30° of flexion, but occurred from 30° to 90° of flexion following UKA. Increasing or decreasing tibial insert thickness following medial UKA also failed to restore the medial pivoting behavior of the intact knee despite modulating MCL and ACL forces. Reduced AP constraint in non‐conforming medial UKA relative to the intact knee leads to abnormal condylar translations regardless of insert thickness even with intact cruciate and collateral ligaments. This finding suggests that the conformity of the medial compartment as driven by the medial meniscus and articular morphology plays an important role in controlling AP condylar translations in the intact tibiofemoral joint during passive flexion. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1868–1875, 2018.
  相似文献   

20.

Purpose

To clarify 1) the force sharing between two portions of BTB graft in anatomic rectangular tunnel (ART) reconstruction and 2) the knee stability in ART technique under anterior tibial load.

Methods

Eleven fresh cadaveric knees were used. First, anterior-posterior (A-P) laxity was measured with Knee Laxity Tester® in response to 134 N of A-P tibial load at 20° on the normal knees. Then ART ACL reconstruction was performed with a BTB graft. For graft, the patellar bone plug and tendon portion was longitudinally cut into half as AM and PL portions. After the tibial bone plug was fixed at femoral aperture, AM/PL portions were connected to the tension-adjustable force gauges at tibial tubercle, and were fixed with 10 N to each portion at 20°. Then the tension was measured 1) under anterior tibial load of 134 N at 0, 30, 60, and 90°, and 2) during passive knee extension from 120 to 0°. Next the graft tension was set at 0, 10, 20, 30, or 40 N at 20°, and the A-P laxity was measured by applying A-P load of 134 N. By comparing the laxity for the normal knee, the tension to restore the normal A-P laxity (LMP) was estimated.

Results

The AM force was significantly smaller at 0° and larger at 90° than the PL force under anterior load, while the force sharing showed a reciprocal pattern. During knee extension motion, the tension of both portions gradually increased from around 5 N to 20–30 N with knee extended. And the LMP was 1.6 ± 1.0 N with a range from 0.3 to 3.5 N.

Conclusion

The pattern of force sharing was similar to that in the normal ACL in response to anterior tibial load and during passive knee extension motion. LMP in this procedure was close to the tension in the normal ACL.

Level of evidence

Level IV, a controlled-laboratory study.  相似文献   