共查询到20条相似文献,搜索用时 0 毫秒
1.
钟敏 《临床超声医学杂志》2019,21(4)
目的 探讨经食管实时三维超声心动图(RT-3D-TEE) 在成人房间隔缺损(ASD)封堵术前评估中的应用价值。方法 43例经胸二维超声(2D-TTE)拟诊为继发孔型ASD的成人患者进行了RT-3D-TEE检查,重点观察ASD缺损口的形态,测量ASD最大径、缺损口形态及各方位的残缘及与腔静脉的距离。筛选可封堵的病例行经导管ASD封堵术,分析缺损最大径与封堵器型号的平均绝对误差,以评价各种成像方法测量的准确性。结果 3例ASD过大,RT-3D-TEE未能获得完整的三维重建图、1例经TEE诊为原发孔型ASD未入组;39 例RT-3D-TEE 显示满意,确诊为继发孔型ASD(以下简称ASD),其中 27 例ASD形态为椭圆形,6 例为类圆形,1 例为筛孔型,5例为不规则型;16例ASD各方位有较完整的残缘,23例存在一侧以上的残缘缺失;临床根据RT-3D-TEE检查ASD大小、形态及各方位残缘等条件筛选后,有23例进行了经导管ASD封堵术,成功21例(成功率91.3%,21/23),未成功的2例及未进行封堵术的6例(共8例)进行了外科修补术,11例出院择期治疗或放弃治疗。RT-3D-TEE测量的缺损最大径和封堵器直径的平均绝对差值小于TTE、TEE-Xplane(经食管双平面成像)这两种方法的结果,且差异有统计学意义( p<0.05)。结论 RT3D-TEE能清晰显示ASD的三维重建切面,逼真地显示ASD的形状,直观、精准测量缺损口的各种径线,在封堵术前评估内科导管介入封堵和外科修补治疗方案选择中有更重要的指导价值。 相似文献
2.
3.
目的:探讨彩色实时三维超声心动图在室间隔缺损介入治疗中的应用价值。方法:对36例先天性室间隔缺损患者在实时三维超声心动图及彩色实时三维超声心动图监测下,经心导管行室间隔缺损封堵术。结果:34例室间隔缺损患者术前经胸超声心动图和彩色实时三维超声心动图估测室间隔缺损的最大径与造影估测的大小的相关性分别为r=0.97(P〉0.05)及r=0.99(P〉0.05),彩色实时三维超声心动图能立体显示室间隔缺损的血流起源、方向和立体空间分布,能准确引导室间隔缺损介入手术。结论:彩色实时三维超声心动图对室间隔缺损封堵术前的诊断、疗效评估和预后评价方面具有重要的临床应用价值和应用前景。 相似文献
4.
目的 初步探讨实时三维心动图在房间隔封堵术中的临床应用价值。 方法 应用Philips Sonos 7500超声诊断仪、X4探头。对4例先天性心脏继发孔型房间隔缺损患者在实时三维超声心动图监测下,经心导管行房间隔缺损封堵术。其中男性1例,女性3例,平均年龄为60.5±8岁。 结果 实时三维超声心动图能真实地显示房间隔缺损的形态、大小、部位及空间关系,能准确引导房间隔缺损介入手术。 结论 实时三维超声心动图在引导介入治疗手术中提供快速而准确的监测手段。 相似文献
5.
经胸与经食管超声心动图在房间隔缺损介入治疗中的应用 总被引:1,自引:0,他引:1
目的探讨经胸与经食道超声心动图在房间隔缺损(ASD)经皮介入治疗中的应用。方法选择2005年5月至2009年9月期间在本院接受经皮房间隔缺损封堵术的92例患者,所有患者均经过临床、心电图、X线平片及经食管超声(TEE)和/或经胸超声心动图(TTE)检查诊断为继发孔型ASD,并根据超声心动图检查结果选择封堵器大小,均经股静脉途径放置封堵器,患者术后即刻、1周复查1TrE、心电图。结果共有91例患者封堵成功,1例患者因封堵器脱落行急诊手术,经胸与经食管超声对ASD直接测量,差异有统计学意义。结论ASD介入治疗总体有效,术前慎密综合超声心动图检查结果选择适合封堵术患者及选择封堵器直径是保障治疗成功的关键,经食管超声在ASD经皮封堵术治疗中仍有重要的使用价值。 相似文献
6.
经食管超声心动图对房间隔缺损封堵治疗适应证的筛选和评价 总被引:6,自引:1,他引:6
目的 对继发孔型房间隔缺损 (ASD)形态及整体状况进行定量评分 ,从而对欲行介入封堵的ASD术前筛选和术中监测作标准化评价。方法 2 10例经临床及超声心动图等检查确诊的ASD患者 ,所有病例采用Amplatzer封堵器封堵 ,术前行经食管超声心动图 (TEE)检查并根据ASD的大小、形态、位置及周边结构进行评分 ,并据此对ASD进行评价。结果 2 0 4例封堵成功 ,TEE测量ASD最大径 4~ 3 1mm[平均 (19.7± 6.3 )mm ] ,选用封堵器大小 10~ 3 6mm [平均 (2 3 .8± 6.6)mm ]。 6例失败。ASD评分≤ 6分为封堵适应证 ,7~ 9分为相对禁忌证 ,10~ 12分为封堵禁忌证。结论 TEE是诊断ASD最佳影像学检查方法 ,应用TEE评分系统可对ASD封堵适应证作术前筛选。 相似文献
7.
经食管超声在多发房间隔缺损Amplatzer伞封堵治疗中的应用 总被引:7,自引:0,他引:7
目的 探讨多发Ⅱ孔型房间隔缺损 (ASD)经皮导管封堵治疗的可行性及经食管超声 (TEE)在其治疗中的作用和应用价值。方法 16例经临床及超声心动图等检查确诊ASD患者 ,均行TEE检查并在其引导下采用Amplatzer封堵器经导管封堵。结果 16例患者均经TEE确诊为房间隔多发缺损 ,其中 2例为 3个孔 ,14例为 2个孔缺损 ,测量大缺损直径 9~ 2 4mm [(17.2± 4.7)mm ] ,小缺损直径 2~ 9mm [(4 .4± 2 .1)mm ] ,缺损之间间隔组织长 2~ 11mm [(4 .5± 3 .1)mm] ,选用封堵器大小为 13~ 3 4mm [(2 4.2± 6.1)mm ] ,所有病例均封堵成功 ,术后 1月经胸超声复查 3例存在少量房间隔残余分流 ,所有病例未发生严重并发症。结论 TEE可以确诊多发ASD ,采用TEE筛选封堵适宜病例并在术中引导监测封堵是理想的影像学方法 相似文献
8.
房间隔缺损微创封堵术中经食管超声的作用 总被引:22,自引:0,他引:22
目的 探讨房间隔缺损 (ASD)闭合器微创封堵术中经食管超声心动图 (TEE)的作用。方法 在TEE监测下为 17例患者进行了房间隔缺损闭合器微创封堵术。首先用TEE准确定位和测量ASD ,确定ASD类型、大小和边缘长短 ,选择合适的患者 ;然后取右前胸 2 .5~ 3 .5cm长的微创切口 ,在TEE引导下 ,经右心房插入特制推送管 ,将闭合器嵌入ASD处 ,达到封堵目的。结果 17例中 2例TEE发现不符合封堵条件 ,改体外循环下手术。 15例用闭合器封堵成功 ,心内操作时间 10~ 45min ,平均 ( 2 5± 12 )min ,于术后 3~ 4d痊愈出院。 12例患者随访 3~ 9月 ,效果良好 ,无残余分流。结论 TEE对于选择适合闭合器封堵的患者、指导闭合器的释放具有重要的作用。 相似文献
9.
实时三维超声心动图在经皮导管闭合房间隔缺损介入治疗前后的初步应用 总被引:6,自引:5,他引:6
目的 探讨实时三维超声心动图评价经皮导管封堵先天性心脏病房间隔缺损 (ASD)的应用价值。方法 应用实时三维超声心动图对 11例ASD患者术前进行缺损大小、形态、位置及术后对封堵器的形态、位置、塑型及大小进行观察 ,应用全容积三维超声重建进行测量 ,并与二维超声心动图和手术结果比较。结果 术前实时三维超声心动图显示继发孔ASD位置均为中央型 ,缺损形态多为椭圆形 ;测量ASD长径与二维超声心动图比较差异有显著性意义 (P <0 .0 5 ) ,短径、缺损边缘距二尖瓣环的距离、距心房顶部的距离与二维超声心动图比较差异无显著性意义。术后实时三维超声心动图显示封堵器呈双盘状 ,表面无异常回声附着 ,2例封堵器伞盘随心脏舒缩运动变化 ,9例无变化 ;测得封堵器伞腰直径与实际封堵器大小比较差异无显著性意义 (P >0 .0 5 ) ;二维超声心动图测得的缺损口最大径与实际封堵器大小和三维超声心动图测值比较差异有显著性意义 (P <0 .0 5 ) ,但与封堵器大小相关性好 (r =0 .83 ,P <0 .0 5 )。结论 实时三维超声心动图成像速度快 ,可作为介入治疗术前指导、术后评价疗效的重要手段。 相似文献
10.
双平面经食管超声心动图在Amplatzer堵塞器经心导管关闭小儿房间隔缺损中的价值 总被引:2,自引:0,他引:2
目的评价经食管超声心动图(TEE)在Amplatzer堵塞器经心导管关闭房间隔缺损(ASD)中的应用价值.方法对57例继发孔型ASD患者,在TEE监测下应用Amplatzer堵塞器经心导管关闭ASD.结果48例获得成功,由于术前经胸超声心动图诊断不准确,9例未成功.ASD的经胸超声测量值与球囊伸展径间差异有显著性意义(P<0 01),但相关(r=0.87,P<0.01);TEE测值与球囊伸展径间高度相关(r=0.93,P<0.01).术后即刻TEE检查显示7例患者存在微量残余分流.结论TEE可以准确地显示ASD的大小、部位及其边缘的解剖形态,有利于术前病例的选择、术中闭合器的安置及术后即刻疗效的判定,是一种安全、有效的监测手段. 相似文献
11.
目的 探讨实时三维经食管超声心动图(RT-3D TEE)评价房间隔缺损(ASD)的大小、形态及边缘等随心动周期的动态变化特征及其影响因素.方法 对20例继发孔型ASD患者(20个ASD)分别应用二维经食管超声心动图(2D-TEE)及RT-3D TEE测量ASD的最大径,并与经皮导管球囊充盈测量直径(stretched balloon diameter,SBD)或开胸手术测值进行相关分析.通过实时三维3D-Zoom获得ASD三维外科医生观,观察RT-3D TEE状态下ASD的形态、边缘及毗邻等随心动周期的变化特征.测量RT-3DTEE状态下的ASD面积和最大径在心动周期不同时相的数值,计算最大面积变化率和直径变化率,并利用多元线性回归逐步分析法分析其影响因素.结果 ①RT-3D TEE所见的ASD形状在收缩末期时常表现为类圆形或椭圆形,舒张末期时常表现为不规则形或椭圆形.②RT-3D TEE所测ASD的面积和最大径在等容收缩期时最小,等容舒张期时最大,最大径与SBD的相关系数为0.962,优于2D-TEE所测ASD最大径与SBD的相关系数(0.820).③RT-3D TEE所测得的ASD的面积变化率为11.48%~71.12%,最大径变化率为2.8%~43.87%,两者间的相关系数为0.879.结论 RT-3D TEE能实时、直观、清晰、完整地显示ASD随着心动周期而呈周期性变化的特征,弥补2D-TEE视角上的缺陷,为经皮导管球囊介入术和开胸手术治疗术前提供完整的信息.Abstract: Objective To determine whether real-time three-dimensional transesophageal echocardiography(RT-3D TEE) is an accurate non-invasive technique for defining the morphology of atrial septal defects(ASD). Methods In 20 patients with secundum ASD, mean age 42.2 years (7 male, 13 female) ,live three dimensional surgical views of ASD were acquired,qualitative morphology of ASD such as the shape, presence of fenestrations and the defect margins were noted during the cardiac cycle. The measurements obtained from 2-dimensional transesophageal echocardiography(2D-TEE) and RT-3D TEE were compared to those obtained from stretched balloon diameter(SBD) or surgery. Measurements of the size and area change of ASD were validated during the cardiac cycle by RT-3D TEE,stepwise multiple linear regression analysis was performed to test the correlation between the maximum change ratios of area and diameter of ASD and age, atrial septal length, ASD shunting velocity, the maximum diameter of ASD and right ventricular systolic pressure. Results ① The morphology of ASD was circle-like or elliptical in systole,irregular or elliptical in diastole. ②The area and diameter of ASD measured by RT-3D TEE was minimal in isovolumetric contraction phase, maximal in isovolumetric diastole phase. The correlation coefficient of maximum diameter measured by 3D with SBD was 0.962 , greater than that by 2D and SBD (0.820). ③The change ratio of area and maximum diameter of ASD acquired by RT-3D-TEE was 11.48%-71.12% and 2.80%-43.87% respectively,and the correlation coefficient of them was 0.921. Conclusions RT-3D TEE using live 3D-Zoom mode accurately displayed the varying morphology,dimensions and spatial relations of ASD. RT-3D TEE can offer visualization morphological changing of ASD in different periods of cardiac cycle,providing more information for percutanous catheter intervention and open heart surgery. 相似文献
12.
经食管三维超声心动图问世于20世纪90年代初,先后经历了经食管静态三维超声心动图、经食管动态三维超声心动图和经食管实时三维超声心动图(Real-time three-dimensional transesophageal,RT-3D—TEE)3个阶段。RT-3D—TEE的问世,是超声技术发展中又一历史性飞跃,该技术将经食管超声检查技术与实时三维超声技术完美结合, 相似文献
13.
目的 探讨非X线下、经胸超声心动图[常规经胸二维超声(TTE)和实时三维超声(RT-3DE)]全程引导经导管房间隔缺损封堵术(TCASD)的方法学要点和临床应用价值.方法应用GE Vivid 7彩色超声诊断仪,普通二维及矩阵3V经胸探头,在完全脱离X线条件下,实时引导11例房间隔缺损(ASD)患者的TCASD术.在常规二维多切面观察的基础上,结合RT-3DE引导多功能导管经腔静脉进入右房;引导导管经缺损进入左房并抵左上肺静脉;引导输送鞘准确进入左房中部;引导封堵器双面伞在左房展开,贴靠入位并准确释放.同期与58例条件类似行常规X线和TTE引导的TCASD患者比较.结果所有手术均顺利完成,无心包填塞等重大并发症发生,与对照组相比,除手术时间显著延长外,研究组在手术即刻及随访3 d、3个月内,残余分流、封堵器移位、房室瓣反流、栓塞及心律失常等并发症发生率与对照组比较差异无统计学意义.结论非经X线条件下、TTE结合RT-3DE全程引导TCASD是安全、经济、实用的超声介入技术,可减少对X线引导封堵的依赖性,对孕妇和儿童实施封堵治疗减少辐射伤害尤为有效. 相似文献
14.
经胸超声心动图在引导房间隔缺损经右心导管封堵术中的临床价值 总被引:10,自引:2,他引:10
目的 评价经胸彩色多普勒超声引导经导管房间隔缺损 (ASD)封堵术的可靠性及应用方法。方法37例房间隔缺损患者 ,采用经胸彩色超声心动图检查 ,多个切面综合判断房间隔缺损的伸展径。比较超声测量值与封堵成功所选用的封堵器大小之间的相关性。结果 35例患者经胸超声引导经右心导管封堵房间隔缺损术成功 ,超声测量的最大伸展径与ASD实际最大伸展径一致 ,r =0 .97,P <0 .0 0 1。 33例ASD封堵器一次放置成功 ,2例测量偏小 ,第二次放置成功 ;封堵术成功后即刻彩超显示穿隔血流消失 ;术后 3月复查 ,房间隔无穿隔血流 ,右心系统明显回缩。结论 经胸彩色多普勒超声引导经右心导管房间隔缺损封堵术准确性高 ,方法简便 ,无痛苦 ,值得推广。 相似文献
15.
目的 探讨经食管超声心动图(TEE)在经胸微创房、室间隔缺损封堵治疗中的应用价值.方法 经胸超声心动图(TTE)粗筛34例房间隔缺损(ASD)患者和38例室间隔缺损(VSD)患者,拟行经胸微创封堵治疗.术中行TEE根据缺损位置、类型、大小选择合适的封堵器;引导封堵器放置,评价即刻封堵效果;术后1周内复查.结果 32例ASD和29例VSD患者封堵成功.术后I周内超声随访,封堵器位置均正常,3例ASD患者微量残余分流,患者心室重构改善,瓣膜反流程度减轻,肺动脉压力下降.结论 TEE对选择适合行经胸微创封堵的ASD、VSD患者、选择合适的封堵器、协助封堵器的释放,评价疗效均有重要的作用.经胸微创封堵ASD、VSD安全、有效. 相似文献
16.
实时三维超声心动图在室间隔缺损封堵中的应用 总被引:2,自引:1,他引:2
目的探讨实时三维超声心动图在室间隔缺损封堵术中的应用价值.方法对10例确诊的室间隔缺损患者的其中7例膜部室间隔缺损行室间隔缺损封堵术,并于术后行实时三维超声检查.结果窄角实时三维成像可实时显示室间隔缺损大小、部位以及与各房室瓣的空间关系;全容量实时三维图像进行上下、左右、前后切割后,可显示完整的室间隔缺损以及与各瓣膜的空间毗邻关系.实时三维成像可立体显示室间隔缺损封堵器的右心室伞、左心室伞以及封堵器随心脏运动的情况,有助于判断封堵效果.结论实时三维超声心动图可以反映室间隔缺损的立体空间结构,为介入封堵治疗提供准确的信息. 相似文献
17.
目的前瞻性观察实时三维经胸超声心动图(RT 3-D TTE)在Ⅱ孔型房间隔缺损(Ⅱ ASD)介入治疗中的应用价值.方法对13例Ⅱ ASD患者在介入治疗术中,同时行RT 3-D TTE和经食管超声心动图(TEE)全程监控导管走行、测量ASD直径、观察封堵伞位置,并对测量结果进行比较分析.结果 RT 3-D TTE和TEE对13例患者均可达到同样的影像辅助监测作用,在对ASD直径的测量中,球囊测量均值为(20.08±3.84)mm、TEE为(19.0±3.87)mm、RT 3-D TTE为(19.38±3.01)mm,三者间相比无显著性差异(P>0.05),但回归方程中发现RT 3-D TTE的估计标准误(SEE=1.65)较TEE的估计标准误(SEE=1.95)小.结论 RT 3-D TTE检查无创、无痛苦、图像直观,显示了较强的临床实用性,但其无法使用多普勒对残余分流情况进行评价. 相似文献
18.
经食管实时三维超声心动图的临床应用进展 总被引:1,自引:2,他引:1
经食管实时三维超声心动图(RT-3D-TEE)是心脏超声发展的飞跃,因其操作简单、实时采集、快速成像,可同步显示三维立体影像,在术前诊断、手术方案制定、术中监测及手术效果评价方面均有独特的优势,在心脏瓣膜病变、先天性心脏病和心脏肿瘤等疾病的诊断方面展现出良好的应用前景。本文就RT-3D-TEE在临床的应用情况做一综述。 相似文献
19.
目的:评价超声心动图监测经心导管房室间隔缺损封堵术并发症的价值,并探讨手术失败原因。方法:79例房间隔缺损(ASD)、6例膜部室间隔缺损(VSD)患者在经食管或经胸超声心动图(TEE、TTE)监测下行经心导管封堵术。结果:73例ASD、6例VSD封堵成功。6例ASD封堵失败,其中1例封堵器脱落,游离于右心腔内;2例术中心导管戳破左房耳致急性心包填塞;2例因ASD太大缺乏合适尺寸的封堵器而终止手术;1例为筛孔状ASD。1例ASD术后随访有少量残余分流。结论:超声心动图(TTE和TEE)能够正确估测房室间隔缺损的大小和位置,利于术前的病例选择、术中监测封堵器放置和并发症发生。超声检查详尽了解缺损大小和边缘情况在该手术方法中必不可少。 相似文献
20.
超声在房间隔膨出瘤并继发孔型房间隔缺损封堵术中的应用 总被引:7,自引:1,他引:7
目的 探讨超声心动图在房间隔膨出瘤(ASA)并发继发孔型房间隔缺损(ASD)封堵治疗中的应用价值。方法 应用经食管超声心动图(TEE)或经胸超声心动图(TTE)诊断ASA并发ASD17例,所有患者均在X线和术中TTE监测下行封堵治疗,术后TTE跟踪复查评价其疗效。结果 17例患者封堵器置人均获成功,共放置24个封堵器。封堵器选择的大小与术前判断大小相关性好(r=0.91,P〈0.001)。术后即刻显示17例患者21个封堵器处穿隔血流消失,有3例患者3个封堵器处仍有微量残余分流,术后1个月至3年复查1例有微量分流。结论 ASA并发ASD的患者可行封堵治疗且疗效确切,而超声心动图在病例选择、术中引导等方面有其特殊性,应引起超声医生和临床医生的重视。 相似文献