目的 利用中国人仿真胸部模型来测量不同噪声指数下胸部各组织器官的吸收剂量,计算有效剂量(ED)并对MSCT胸部扫描进行剂量评估.方法 对CDP-1C型中国人仿真胸部体模在CT体层解剖和X线衰减两方面进行等效性论证;通过在体模内布放热释光剂量计(TLD)来测量不同噪声水平下各组织器官的吸收剂量,并记录相应的剂量长度乘积(DLP);将两者分别换算为ED后选择单因素t检验方法进行对比研究,分析自动管电流调制(ATCM)技术时不同噪声指数胸部CT扫描的剂量水平.结果 中国人仿真胸部体模与成人CT胸部图像的结构相似.体模主要器官平均CT值为肺-788.04 HU、心脏45.64 HU、肝脏65.84 HU、脊柱254.32 HU,与成人偏差程度分别为肺0.10%、心脏3.04%、肝脏4.49%、脊柱4.36%.肝脏的平均CT值差异有统计学意义(t=-8.705,P<0.05);肺、心脏和脊柱平均CT值与人体差异无统计学意义(t值分别为-0.752、-1.219、-1.138,P>0.05).当噪声指数从8.5逐渐增至22.5时,DLP从393.57 mGy·cm递减至78.75 mGy·cm,各器官吸收剂量呈下降趋势(以肺为例,平均吸收剂量从22.38 mGy递减至3.66 mGy).应用DLP所计算的ED较器官吸收剂量计算的ED偏低(以噪声指数为8.5为例,两种方法的ED分别为6.69和8.77 mSv).结论 应用中国人仿真体模来进行CT剂量评估更为准确;基于ATCM技术的胸部CT扫描噪声指数设定至少应大于8.5.
Abstract:
Objective Using the Chinese anthropomorphic chest phantom to measure the absorbed dose of various tissues and organs under different noise index, and to assess the radiation dose of MSCT chest scanning with the effective dose(ED). Methods The equivalence of the Chinese anthropomorphic chest phantom(CDP-1C) and the adult chest on CT sectional anatomy and X-ray attenuation was demonstrated. The absorbed doses of various tissues and organs under different noise index were measured by laying thermoluminescent dosimeters(TLD) inside the phantom, and the corresponding dose-length products(DLP) were recorded. Both of them were later converted into ED and comparison was conducted to analyze the dose levels of chest CT scanning with automatic tube current modulation (ATCM) under different noise index. Student t-test was applied using SPSS 12.0 statistical software. Results The Phantom was similar to the human body on CT sectional anatomy. The average CT value of phantom are -788.04 HU in lung,45.64 HU in heart,65.84 HU in liver,254.32 HU in spine and the deviations are 0.10%,3.04%, 4.49% and 4.36% respectively compared to humans. The difference of average CT value of liver was statistically significant(t=-8.705,P<0.05),while the differences of average CT values of lung, heart and spine were not significant(t value were -0.752,-1.219,-1.138,respectively and P>0.05).As the noise index increased from 8.5 to 22.5, the DLP decreased from 393.57 mGy·cm to 78.75 mGy·cm and the organs dose declined. For example, the average absorbed dose decreased from 22.38 mGy to 3.66 mGy in lung. Compared to ED calculating by absorbed dose, the ED calculating by DLP was lower. The ED values of the two methods were 6.69 mSv and 8.77 mSv when the noise index was set at 8.5. Conclusions Application of the Chinese anthropomorphic chest phantom to carry out CT dose assessment is more accurate. The noise index should be set more than 8.5 during the chest CT scanning based on ATCM technique.  相似文献   

2.
目的 探讨应用自动管电流调制技术(ATCM)对腹部CT图像质量及辐射剂量的影响.方法 通过实体测量因病情需要行腹部CT检查的68例体质量指数(BMI)为18 ~ 24 kg/m2的成年男性腹部CT扫描的腹部径向数据,借鉴CTP515辅助测试模体,制作符合国人尺寸的腹部体环,嵌套Catphan600性能测试模型为观察对象,模拟成人腹部CT低、高对比特点用于实验研究.以管电压120 kV,固定管电流450 mA组为对照组;相同管电压条件下,自动管电流技术组为实验组,其中噪声指数(NI)值设置为4 ~ 20,共14组,管电流范围10~ 450 mA.对模型进行扫描.测量Catphan600模体中心均质区域CT值,验证模型对X线衰减的等效性.记录每组扫描方案的辐射剂量指标容积CT剂量指数(CTD Ivol)、个体化剂量估计值(SSDE)、剂量长度积(DLP)、有效剂量(ED)及图像质量客观评价指标图像噪声值(SD)、对比噪声比(CNR).同时由3名分别来自不同医院有5年以上工作经验的腹部诊断医师对Catphan600模体中的CTP515低对比目标显示程度(LCD)模块及CTP528高对比目标显示程度(HCD)模块进行独立主观评价.对NI值与SDb、CNR、CTDIvol、DLP间的相关性采用Pearson相关分析,与LCD模块评分间相关性采用Spearman秩相关分析.不同NI组间SD、CNR及CTDIvol值与对照组的比较采用t检验.LCD和HCD评分的组内比较采用Kruskal-Wallis秩检验,组间差异采用Mann-Whitney U Test秩检验.3名放射科医师主观评价结果的一致性检验采用Kappa分析.结果 实测人体正常肝脏组织CT值为(52.8 ±9.1)HU,腹部模体中心区域平均CT值为(50.8±1.0) HU,两者差异无统计学意义(t=0.31,P>0.05),偏差程度为4.9%.此模型与成人腹部对X线衰减具有较好的等效性.所有辐射剂量指标均随NI值增大而降低,NI值增加1个单位,辐射剂量指标CTDlvol、SSDE、DLP和ED值分别平均下降1.23 mGy、2.03 mGy、13.20 mGy·cm、0.20 mSv.NI值与图像质量主、客观评价指标及辐射剂量指标间呈高度线性相关(r=0.871~0.982,P值均<0.05).实验组NI =4 ~7组与对照组间SD、CNR差异均无统计学意义(t值分别为-1.63 ~-0.17,0.03 ~1.12,P值均>0.05).实验组NI=4~ 10组与对照组间LCD评分差异均无统计学意义(Z值为-1.637 ~0.000,P值均>0.05).实验组NI =4 ~ 13组与对照组间HCD得分差异均无统计学意义(Z值为-1.423 ~0.000,P值均>0.05).3名医师对LCD、HCD评分的Kappa一致性检验结果分别为0.743、0.795.结论 在腹部CT扫描中应用自动管电流调制技术可确保图像质量,同时降低辐射剂量.  相似文献   

3.
头颈部多层螺旋CT辐射剂量调查   总被引:5,自引:0,他引:5  
目的 了解我国头颈部多层螺旋CT扫描剂量.资料与方法 发出头颈部CT扫描参数剂量调查表到国内7家东芝64层螺旋CT用户.查阅2002年1月至2007年7月期间中华放射学杂志、临床放射学杂志和实用放射学杂志三大杂志有关头颈部多层螺旋CT论文并测算其剂量.结果 东芝64层螺旋CT扫描:头部平均毫安秒为189.4 mAs、CT剂量指数(CTDIvol)为47 mGy;鼻窦95 mAs、22.5 mGy,眼眶为74.3 mAs、17.9 mGy,颌面部为100 mAs、22.5 mGy,颞骨144.6 mAs、44.7 mGy,颈部131.3 mAs、16.3 mGy.其他螺旋CT为头部平均毫安秒为280 mAs;鼻窦为100 mAs,眼眶200 mAs,颌面部为200 mAs,颞骨196.7 mAs,颈部220 mAs.结论 我国头颈部多层螺旋CT检查条件剂量不规范、不统一,有待优化.  相似文献   

4.
目的:通过对头部体模扫描试验,探讨成人头颅CT低剂量扫描参数。方法:以层厚10 mm,扫描时间为1 s,通过改变mA值,以10 mA为间隔,20-300 mA间29个不同mA条件对头部体模进行轴向扫描,对容积CT剂量指数(CTDIvol)、噪声(SD)和对比-噪声比(CNR)进行客观评价分析与统计学处理,对图像低密度分辨力进行主观评价。结果:①CTDIvol随mAs增大而增大,呈线线关系;与300 mAs的CTDIvol(42 mGy)比较,80-150 mAs的CTDIvol(11-21 mGy)下降73%-50%。②SD值随mAs升高而降低;SD值随mAs变化曲线可分为SD改变非常显著段(20-50 mAs)、显著段(50-80 mAs)、缓坡段(90-150 mAs)和平缓段(160-300 mAs)。③CNR随mAs改变与SD值改变相反。④SD值与CNR统计学处理:20 mAs与30 mAs、30 mAs与50 mAs5、0 mAs与80 mAs、80 mAs与150 mAs、150 mAs与300 mAs的各SD值及CNR有统计学差异(P〈0.05);160-300 mAs的各SD值与CNR无统计学差异(P〉0.05)。⑤图像LCR主观评价:20-50 mAs,分辨低密度圆柱体困难;50-80 mAs,主观图像质量明显下降,图像对诊断有影响;90-150 mAs主观图像质量有一定改变;160-300 mAs主观图像质量改变不明显。结论:80-150 mAs为低对比要求较高的成人颅脑低剂量平扫可用区间,为临床降低扫描剂量提供了依据。临床患者检查,可以用100 mAs进行平扫,CT剂量指数明显降低。  相似文献   

5.
目的 评价噪声关联z轴管电流调制技术降低多层CT胸部扫描的辐射剂量、提高图像质量(信噪比水平)的效果.方法 连续200名CT定位像未显示明显胸部异常的受检者,按前瞻性的研究方法 进行分组,根据检查顺序的单双数随机分为z轴管电流调制组(单数者为试验组)和管电流固定组(双数者为对照组),每组100名.试验组的目标噪声水平设置为10.0 HU,扫描设备根据定位像扫描时获取的胸部密度信息自动设置扫描时的动态管电流值;对照组的管电流设置为200 mA,其他扫描参数与试验组完全相同.分别记录2组的最大管电流、CT剂量容积(CTDIv01)、剂量长度乘积(DLP)和女性乳房最大层面的管电流值;测量肺尖、主动脉弓、左心房和肺底层面的图像噪声.图像质量分3级(优、良、差),由2名有经验的CT技师采用双盲法评价.计数资料采用成组设计的x2检验,计量资料采用成组设计的t检验,P<0.05为差异有统计学意义.结果 试验组的最大管电流、CTDIvol、DLP和乳房最大层面管电流的平均值分别为(178.5±125.6)mA、(10.5±3.8)mGy、(231.6±24.3)mGy/cm和(116.0±22.5)mA;对照组的分别为200.0 mA、12.8 mCy、(274.7±18.4)mGy/cm和200.0 mA,试验组较对照组分别降低10.8%、19.9%、15.7%和42.0%,两组差异有统计学意义(P值均<0.05).试验组肺尖和肺底层面的图像噪声分别为10.5和10.4 HU,明显低于对照组的15.3和15.6 HU;图像质量优的数量大幅增加.结论 噪声关联z轴管电流调制技术实现了受检者个性化适应性曝光,在胸部扫描时可明显降低受检者的整体辐射剂量,并提高图像质量.  相似文献   

6.
降低CT辐射剂量研究新进展   总被引:1,自引:0,他引:1  
CT技术的快速发展给人们带来极有益的诊断信息,但CT的过度使用也使辐射风险加大。如何在保证图像质量的前提下尽可能的降低辐射剂量成为当今的焦点。本文就降低CT扫描辐射剂量的技术和方法及一些新措施进行探讨。  相似文献   

7.
目的 探讨64层CT的MinIP与MPR在显示孤立性肺病变(SPL)相关支气管中的临床应用价值.方法 回顾性分析64层CT可明确显示SPL相关支气管关系者75例,将0.625 mm薄层重建图像沿SPL相关支气管长轴分别重组为2个斜面的MinIP和MPR图像,重组层厚分为1、2、3和5 mm 4组,对显示支气管和屏蔽肺血管方面进行图像质量评估.采用方差分析及组内相关系数进行统计学分析.结果 (1)两斜面显示SPL相关支气管4组MinIP图像的平均积分(1 mm均为4.85分,2 mm分别为4.77和4.84分,3 mm分别为4.63和4.67分,5 mm分别为4.25和4.28分)和1、2 mm层厚组MPR图像(1 mm分别为4.77和4.76分,2 mm分别为4.04和4.27分)均优良.两斜面MPR图像1 mm层厚组的平均积分与MinIP图像1~3 mm层厚组差异无统计学意义(t值均为0.318,P值均>0.05),明显高于5 mm层厚组(t值分别为6.318和6.610,P值均<0.01);两斜面MPR图像2 mm层厚组的平均积分较MinIP图像1~3 mm层厚组低(t值5.003~8.958,P值均<0.01),与5 mm层厚组差异无统计学意义(t值分别为1.794和0.3181,P值均>0.05).(2)两斜面MinIP图像肺血管屏蔽随层厚增厚效果越好(F值分别为45.312和40.415,P值均<0.01),3、5 mm层厚组平均积分(3 mm分别为4.67和4.64分,5 mm分别为5.00和4.97分)均优良,而2 mm层厚组平均积分(2 mm分别为3.32和3.20分)一般.结论 3 mm层厚的MinIP可清晰显示孤立性肺病变相关支气管.
Abstract:
Objective To investigate the clinical value of 64-slice computed tomography with MinIP and MPR for imaging the bronchus related to a solitary pulmonary lesion (SPL). Methods Seventy-five subjects with solitary pulmonary lesions underwent chest 64-slice CT and their bronchi were analyzed retrospectively. All images of thin-section (0.625 mm) were reconstructed with MPR and MinIP into images of 1, 2, 3, and 5 mm thickness and 1 mm gap in two orthogonal planes along the long axis of bronchus related to the SPL. The image quality of four series of MinIP and MPR images was evaluated in the aspect of bronchus visibility and pulmonary vascular masking. One-way ANOVA with Bonferroni correction and interclass correlation coefficient were used in the statistical analysis. Results (1) The mean scores of display of the bronchi on MinIP images of four series (4.85, 4.77 and 4.84, 4.63 and 4.67, 4.25 and 4.28, in 1, 2, 3, and 5 mm thickness, respectively) and on MPR images of 1 or 2 mm thickness (4.77 and 4.76, 4.04 and 4.27, in 1 and 2 mm thickness, respectively) were good or excellent. MPR images of 1 mm thickness and MinIP images of 1-3 mm thickness showed no significant differences (t=0.318, P> 0.05 for all), but they were superior to MinIP images of 5 mm thickness (t=6.318 and 6.610, P<0.01). MPR images of 2 mm thickness were inferior to MinIP images of 1-3 mm thickness (t=5.003-8.958, P<0.01), but there was no significant difference between MPR images of 2 mm thickness and MinIP images of 5 mm thickness (t=1.794 and 0.3181, all P> 0.05). (2) The effect of suppression of pulmonary vascular markings on MinIP images was better with the increase of slice thickness (F=45.312 and 40.415, P<0.01). The mean scores of MinIP images of 3 mm and 5 mm thickness (4.67 and 4.64, 5.00 and 4.97, for 3 and 5 mm thickness, respectively) were good or excellent, but MinIP images of 2 mm thickness were just acceptable. Conclusion MinIP images of 3 mm thickness may display the bronchus related to SPL more clearly.  相似文献   

8.
CT冠状动脉成像技术已经成为临床评价冠状动脉的无创性的重要检查手段,然而随着采集层厚变薄、扫描范围增大及采集效率的改变,其辐射剂量较对其他部位检查的明显要高.如何在保证图像质量的前提下,有效降低辐射剂量已愈加引起研究人员的关注.现就其最新的研究进展予以综述.  相似文献   

9.
CT冠状动脉成像技术已经成为临床评价冠状动脉的无创性的重要检查手段,然而随着采集层厚变薄、扫描范围增大及采集效率的改变,其辐射剂量较对其他部位检查的明显要高.如何在保证图像质量的前提下,有效降低辐射剂量已愈加引起研究人员的关注.现就其最新的研究进展予以综述.  相似文献   

10.
目的 比较容积高分辨率CT(VHRCT)与常规高分辨率CT(CHRCT)的图像质量,探讨VHRCT的可行性.方法 对Catphan 412模具行VHRCT及CHRCT扣描,测量和记录图像的空间分辨率、噪声及放射剂量并进行比较;对32例患者行VHRCT及CHRCT检查,对图像质量进行评分并比较.模具部分采用配对t检验比较噪声的差异;临床部分采用Wilcoxon配对符号秩和检验比较图像质量的差异.结果 模具研究中,VHRCT横断面图像的空间分辨率与CHRCT相同,均为11 LP/cm,其z轴分辨率为12 LP/cm.剂量相近时,VHRCT的噪声为(69.18±2.77)HU,大于CHRCT的噪声(54.62±2.12)HU,(t=-15.929,P<0.01);噪声相近时,VHRCT的剂量较CHRCT增加19.09 mGy.临床研究中,VHRCT与CHRCT横断面图像的质量评分分别为3.22与3.24,差异无统计学意义(Z=-0.319,P>0.05),VHRCT与CHRCT冠状面蕈建图像的质量评分分别为3.05与1.88,差异有统计学意义(Z=-5.088,P<0.01).结论 对于64层CT,VHRCT的横断面图像质量接近CHRCT,多平面重组图像具有高分辨率可广泛应用,其扫描剂量尚有待优化.  相似文献   

11.
数字化体层融合在肺结节探查中的初步应用   总被引:4,自引:0,他引:4  
目的 探讨数字化体层融合在肺结节探查中的应用价值.方法 30例疑有肺内结节的患者,均先后行胸部X线平片、体层融合和CT检查.将上述影像资料传至后处理工作站,由2名具有3年以上胸部影像诊断经验的医师分别进行双盲法阅片,观察每例患者肺部结节的数量,每个肺结节的部位、大小.然后,2名阅片者再共同阅片,使单独阅片不一致的结果得到统一.以CT结果作为标准,分别计算胸部X线平片和体层融合探查肺结节的敏感性.采用配对四格表资料的X~2检验比较两者的差异性.结果 30例患者,胸部X线平片检查9例阴性,21例阳性,共发现肺结节40个.体层融合检查4例阴性,26例阳性,共发现肺结节89个.CT检查3例阴性,27例阳性,共发现肺结节102个.以CT作为标准对照,胸部X线平片探查肺结节的敏感性为27.4%(28/102),体层融合的敏感性为87.2%(89/102),差异有统计学意义(X~2=4.35,P<0.05).结论 数字化体层融合可显著提高肺结节探查的敏感性,可以作为胸部X线平片良好和必要的补充.  相似文献   

12.
多层螺旋CT胸部低剂量扫描发现肺结节的临床研究   总被引:26,自引:0,他引:26  
目的 研究降低电流对发现肺结节,尤其是直径≤5mm结节的影响,并观察低剂量CT在胸部初步应用的影像效果。方法 对6例病理证实为肺内多发结节的尸检离体肺脏制成充气固定的肺标本,分别行多层螺旋CT的常规剂量(130mA)和低剂量CT(50、30、10mA)扫描。对40例体检者和60例转移瘤近期复查的患者行低剂量CT(30mA)扫描。记录直径≤5mm的结节的数目并判断影像有无伪影。根据诊断的把握度将结节分为肯定是结节、不能确定和肯定不是结节。对40例体检者及60例转移瘤仅评价影像的伪影情况。结果 肺标本研究中,低剂量各组(50、30、10mA)的Kappa值为0.515、0.242、0.154。经U检验,低剂量50mA组与常规剂量组结节的发现一致性较好。50、30、10mA组的敏感度分别为88.0%、78.4%、75.0%,阳性预测值分别为98%、94%、93%,准确度分别为85%、73%、69%。标本影像仅在10mA组中21幅(70%,21/31)图像的椎体旁的肺区见到细小条状伪影。100例病人的影像中仅在3例的肺尖可见到能影响小结节发现的条状伪影。结论 低剂量CT有望提高肺癌的早期发现。低剂量50mA组对直径≤5mm的结节能可靠发现。研究显示30mA可得到满意的影像质量。有条件者应开展低剂量CT筛查肺癌。  相似文献   

13.
目的 总结3 cm以下肺恶性局灶性磨玻璃结节(fGGO)与实性结节的MSCT征象,旨在发现恶性fGGO是否存在特异性征象.方法 回顾性分析病理证实的3 cm以下的105例实性肺癌和48例恶性fGGO的基本临床资料、病灶大小及MSCT征象(病灶形态、边缘形态、瘤肺界面、内部结构及邻近结构改变),用Fisher确切概率法、X~2检验及非参数Mann-Whitney U检验进行统计学分析.结果 实性结节的男女比例(60:45)高于fGGO组(18:30),男女发病率差异有统计学意义(X~2值5.09,P<0.05).实性结节圆形或类圆形、不规则形、毛刺、空泡征、支气管征走行正常的分别为101、4、60、12、0例;fGGO相应分别为38、10、19、25、7例(X~2值依次为11.48、4.07、29.70、22.38,P值均<0.05),差异有统计学意义.实性结节的边缘形态(分叶、尖角、棘状突起)、瘤肺界面(清楚光整、清楚毛糙、模糊)、内部结构(蜂窝征)、邻近结构(胸膜凹陷征、血管集束征)分别为85、0、33、5、100、0、0、59、35例;fGGO相应分别为42、1、15、3、45、0、2、32、16例(X~2值依次为1.00、2.20、0.00、0.15、4.43、1.50、0.00,P值均>0.05),2组结节之间差异均无统计学意义.结论 恶性fGGO与实性结节的病灶形态、边缘形态、瘤肺界面、内部结构及邻近结构的改变大多数表现一致,但fGGO中不规则形、空泡征和支气管走形自然的概率在一定程度上高于实性结节,毛刺征低于实性结节,这与肿瘤的病理类型及肿瘤的病理学基础存在一定的关系.  相似文献   

14.
16层以上螺旋CT对诊断孤立性肺结节的合理应用分析   总被引:1,自引:0,他引:1  
目的 评价16层以上MSCT对诊断孤立性肺结节(<3 cm)的应用合理性.方法 分析到该院会诊患者的院外胸部CT照片,选择使用16层以上MSCT机型和直径<3 cm孤立性肺结节的150例作为研究对象,记录院外CT片内常规重建层厚、有无靶重建、二维和三维重组应用情况、窗技术应用以及对比剂增强效果等.确定孤立性肺结节的胸部CT正确扫描方法,并与院外胸部CT扫描技术进行对比,评价院外MSCT胸部应用的合理性及正确诊断情况.结果 92例采用16层CT机,54例采用64层CT机,4例为40层CT机.常规重建层厚选择9~10 mm者59例,7~8 mm者12例,5 mm者79例.对病灶局部采用连续薄层(<3 mm)重建46例.9例CT片内仅有重组图像(MPR和VR),没有原始薄层轴面图像.在150例中,由于图像不满意而需重复扫描者53例(35.3%);78例在该院经病理或临床确诊,其中院外诊断错误22例,在该院仅2例诊断错误.结论 16层以上MSCT在孤立性肺结节的应用存在诸多不合理性,直接影响诊断,建议建立国内统一的胸部CT扫描标准.  相似文献   

15.
CT肺灌注在肺结节诊断中的应用研究   总被引:42,自引:0,他引:42  
目的研究CT灌注成像对良、恶性肺结节的诊断价值。方法前瞻性研究88例直径2~4cm的肺结节的多层螺旋CT灌注表现。其中肺癌62例,良性病变26例(炎性假瘤12例,结核球10例,错构瘤3例,曲菌球1例)。采用8层螺旋CT灌注成像,电影模式,层厚5mm,4层/圈,扫描时间1s/r,数据采集时间40s。碘普胺(300mg I/ml)50ml,用高压注射器经前臂浅静脉注射,流率4ml/s,延迟5.6s。CTPerfusion2软件分析测量结节的血流量(BF)、血容量(BV)、平均通过时间(MTT)、表面通透性(PS)和拟合时间-密度曲线。结果良、恶性结节的BV值(分别为5.33、10.00ml/100g)和PS值(分别为13.11、44.94ml.100g-1.min-1)差异有统计学意义(F值分别为29.368和48.027,P值均为0.000)。以BV≥6ml/100g作为恶性病变的阈值,其敏感度87.3%,特异度100.0%,阳性预测值100.0%,阴性预测值65.4%,准确度89.9%。以PS≥30ml.100g-1.min-1作为恶性结节的阈值,则敏感度96.4%,特异度75.0%,阳性预测值87.1%,阴性预测值87.2%,准确度88.6%。以BV≥6ml/100g同时PS≥30ml.100g-1.min-1作为恶性结节的阈值,则敏感度96.8%,特异度92.3%,阳性预测值96.8%,阴性预测值92.3%,准确度95.5%。肺癌的拟合时间-密度曲线和主动脉的关系密切,起始端与主动脉同步,峰值在主动脉峰值区域或稍后,85.5%(B型+C型,53/62)呈缓慢下降或平台型。结论多层螺旋CT灌注对肺结节的良恶性鉴别诊断有较大帮助。  相似文献   

16.
目的 分析CT和正电子发射计算机体层摄影术(PET)诊断孤立性肺结节(SPN)的局限性和二者的协同诊断作用。方法 回顾性分析有病理证实的单个肺结节118例。所有病例CT和PET检查间隔时间〈2周。病灶直径2~4cm,平均2.7cm。118例SPN中,恶性肿瘤87例,其中肺癌85例,结肠腺癌肺转移2例;良性31例,其中结核球8例,错构瘤6例,炎性假瘤6例,慢性非特异性炎症4例,炎性肉芽肿3例,隐球菌感染2例,脓肿和球形肺不张各1例。结果 118例SPN中,CT诊断正确93例,误诊25例,误诊率21.2%。其中12例肺癌误诊为良性,13例良性误诊为肺癌。PET诊断正确96例,误诊22例,误诊率18.6%。其中9例肺癌、1例结肠癌肺转移误诊为良性,12例良性误诊为恶性。CT和PET协同诊断,108例诊断正确,10例误诊,误诊率8.5%。CT、PET单独诊断和协同诊断的敏感性、特异性、阳性预测值、阴性预测值和准确性分别为86,2%、58.1%、85.2%、60,0%、78.8%;88.5%、61.3%、86,5%、65.5%、81.4%和97.7%、74.2%、91,4%、92,0%、91.5%。CT和PET单独诊断SPN的准确性无统计学意义(X^2=0.625,P=0.239),协同诊断与CT、PET单独诊断SPN的准确性有统计学意义(X^2=7.762和5.318,P=0.005和0.021)。结论 良、恶性SPN的CT和PET影像特征均有一定的重叠。单独采用CT或PET诊断肺结节的价值相当,CT和PET协同诊断的准确性高于CT或PET单独诊断。  相似文献   

17.
目的:探讨多层螺旋CT灌注在孤立性肺结节(SPN)首过时血流特征及鉴别诊断中的应用价值。方法:对99例直径2~4 cm的SPN先行32层螺旋CT平扫,再行多层同层连续动态增强扫描,在时间-密度曲线(TDC)的基础上,测量SPN增强峰值(PESPN)、病灶同层主动脉的增强峰值(PEAA)、病灶达峰时间(TTP),并由此计算增强净增值(NE)、结节-主动脉强化峰值比(S/A)、灌注量(Pr),进行统计学分析。结果:恶性与炎性SPN的PESPN、NE、S/A和Pr均高于良性SPN(P均<0.05),其TTP低于良性SPN(P<0.05);恶性SPN的PESPN、NE、S/A高于炎性SPN(P均<0.05);恶性结节的Pr高于炎性结节,但二者之间差异无显著性意义(P>0.05)。以NE≥25 HU作为恶性病变的阈值,其敏感度为98.2%,特异度为52.0%,准确度为86.9%,阳性预测值为85.6%,阴性预测值为92.9%。良性、恶性及炎性结节的TDC形态不同。结论:多层螺旋CT灌注成像技术是定量评价SPN血流模式的无创性技术,有助于SPN的鉴别诊断。  相似文献   

18.
孤立性肺结节CT动态增强扫描的层面优化及临床应用   总被引:5,自引:0,他引:5  
目的利用选层重组的方法改善孤立性肺结节(SPN)CT动态增强扫描各延时像测量层面的一致性,并探讨其临床应用价值。方法(1)对3种均质液体行CT螺旋扫描并在Z轴方向同层厚任意多平面重组,比较其原始扫描图像及重组图像密度测量值的差异。(2)对72例SPN患者行螺旋CT动态增强扫描,运用一定的选层重组的方法保证各延时像测量层面的一致性。并对其中46例经病理及临床证实的SPN的CT动态增强特点进行评价,评估其增强前后的CT值、强化峰值、SPN与主动脉的强化值比。结果(1)不同密度的均质液体同层厚的原始扫描图像及重组图像间密度测量值差异无统计学意义(F=1.544,P>0.05);(2)67例SPN选层重组前、后各延时像测量层面一致率分别为20.98%(14/67)和97.01%(65/67),其差异有统计学意义(χ2=80.22,P=0.00)。多层螺旋CT对5例SPN的选层重组全部成功。(3)SPN的CT动态增强各延时像测量层面一致性优化以后,恶性结节与炎性结节强化峰值[(38.48±14.32)、(42.48±11.55)HU]和结节与主动脉强化值比[(19.64±9.52)、(21.14±7.77)%]均明显高于良性结节[(9.52±3.78)HU、(3.41±1.86)%];P值均<0.01。炎性结节的强化峰值、结节与主动脉强化值比[(42.48±11.55)HU、(21.14±7.77)%]与恶性结节[(38.48±14.32)HU、(19.64±9.52)%]间的差异无统计学意义(P值均>0.05)。CT动态增强选层重组保证各延时像测量层面一致性后,使其对SPN定性的准确率由78%提升至80%。结论螺旋CT扫描Z轴方向同层厚任意重组对均质物质的密度值的测量无明显影响。CT动态增强扫描各延时像测量层面一致性的优化可进一步客观反映SPN的动态增强情况,有利于其形态学的比较及CT值的测量,有望提高其对孤立性肺结节鉴别诊断的能力。  相似文献   

19.
目的 利用16及64层螺旋CT评价孤立性肺结节容积灌注是否均匀.方法 85例孤立性肺结节(直径≤4.0 cm,57例恶性结节,15例活动性炎症,13例良性结节)患者,在增强前、后采用16层(30例)及64层(55例)螺旋CT进行同层动态扫描.注入对比剂后11-41 s,每秒扫描1次;90 s扫描1次.16层螺旋CT扫描层厚:病灶直径3.0~4.0 cm时8.0 mm;2.0~3.0 cm时6.0 mm;1.5~2.0 cm时4.0 mm;1.0~1.5 cm时3.0 mm;<1.0 cm时2.0 mm(其中病灶直径3.0 cm时,层厚8.0 mm;2.0 cm时,6.0mm;1.5 cm时,4.0 mm).64层螺旋CT扫描层厚:病灶直径3.0~4.0 cm时5.0mm;<3.0 cm时2.5 mm.记录孤立肺结节增强前后各时相的CT值.分别计算肺结节3个中央有效层面强化值、灌注值、结节一主动脉强化值比、平均通过时间.使用均数间方差检验进行统计学分析.结果 3个中央层面强化CT值分别为(30.95±14.53)、(25.10±13.32)、(32.37±15.85)HU、灌注值分别为(33.01±21.35)、(23.70±12.87)、(29.00±15.47)ml·min-1·100 g-1,结节-主动脉强化值比分别为(13.58±6.41)%、(10.95±5.76)%、(13.64±6.20)%,平均通过时间分别为(11.61±5.74)、(11.97±3.55)、(13.44±3.74)s,差异均有统计学意义(F值分别为5.913、6.464、5.333、3.837,P值分别为0.003、0.002、0.005、0.023).平扫的CT值差异无统计学意义(F=0.032,P=0.968).结论 孤立肺结节容积灌注是不均匀的,推荐采用CT容积灌注成像的方式对孤立肺结节血流模式进行研究.  相似文献   