首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A rapid microagglutination test has been developed which can be performed in 30 minutes. Ninety-seven percent of 96 patients diagnosed as having Legionella pneumophila (serogroup 1) infection by indirect immunofluorescence were also detected by the rapid microagglutination test.  相似文献   

2.
Indirect immunofluorescence assay titers of human sera obtained against the Legionella pneumophila serogroup 1 antigen (Philadelphia 1 strain) killed with 10% Formalin showed a tendency to be lower than those obtained against the reference heat-killed antigen (geometric mean titer of 194 and 370, respectively) when all other variables in the test were held constant. Test results were interpreted the same for 96% of 60 paired sera if the cutoff level used to interpret a positive test result for the formalinized antigen was lowered by one twofold dilution factor.  相似文献   

3.
The serodiagnostic efficiencies of five different approaches to detecting antibodies (immunoglobulins G, A, and M) developed in clinically proven infections with Francisella tularensis have been assessed. Fifty serum samples from patients suffering from tularemia during an outbreak in Sweden were compared with samples from 50 healthy blood donors (controls) by using an enzyme-linked immunosorbent assay (ELISA), microagglutination (MA), Western blotting (WB), an indirect immunofluorescence assay (IIFA), and flow cytometry (FC). ELISA, WB, and FC were based on the use of preparations of lipopolysaccharides (LPS) of the live vaccine strain of Francisella tularensis subsp. holarctica (ATCC 29684) as a capture antigen. Whole methanol-fixed bacteria were used for IIFA and MA. Optimized protocols yielded a diagnostic sensitivity and specificity of 100% for WB, MA, and FC, 98% for ELISA, and 93% for IIFA. A total of 6,632 serum samples from individuals between the ages of 18 and 79 years, representatively recruited from all regions of Germany, were screened to estimate and confirm the positive predictive value (PVpos) of the ELISA. Serum samples from 15 (0.226%) individuals tested positive for F. tularensis-specific antibodies by ELISA and confirmatory WB. The resulting prevalence-dependent PVpos of 10.2% and specificity of 98.1% were consistent with our findings for tularemia patients and controls. We conclude that the combined usage of a screening ELISA and a confirmatory WB based on LPS as a common antigen, as well as the MA, is a suitable serodiagnostic tool, while the quality of the IIFA is hampered by subjective variations of the results. FC is a promising new approach that might be improved further in terms of multiplex analyses or high-throughput applications.  相似文献   

4.
Sera from six outbreaks of legionellosis and four outbreaks of pneumonia of other etiologies were tested with the indirect immunofluorescence assay (IFA) as currently performed. The current IFA is at least as sensitive as the original test in detecting cases of Legionnaires disease (78 to 91%). By using Center for Disease Control criteria for a positive (fourfold increase in titer during convalescence to greater than or equal to 128) or presumptive (single titer greater than or equal to 256) serological test, the specificity exceeded 99%. No cross-reactions against Legionella pneumophila antigens were observed among sera from epidemic cases of Q fever, tularemia, and psittacosis; the only positive L. pneumophila IFA titer among the epidemic Mycoplasma pneumonia sera was reduced to a negative titer with an immunosorbent extracted from Escherichia coli strain O13:K92:H4. The slight increase in specificity (to 100%), however, was offset by a slight decrease in sensitivity. The sensitivity of the IFA was maximal when a conjugate that detected immunoglobulins G, M, and A was used. IFA titers were not significantly altered by replacing the monovalent serogroup 1 antigen with a polyvalent antigen (serogroups 1 through 4) nor by the presence of rheumatoid factor or heat-labile serum factors.  相似文献   

5.
We evaluated the abilities of the Vircell immunoglobulin G (IgG) and IgM indirect immunofluorescence assay (IFA) for Legionella pneumophila serogroup 1, the IgM and IgG enzyme-linked immunosorbent assay (ELISA) for Legionella pneumophila serogroup 1, and the IgM-plus-IgG ELISA for Legionella pneumophila serogroups 1 to 6 to diagnose Legionnaires' disease (LD) in a well-described sample of patients with and without LD. Also, we determined the agreements, sensitivities, and specificities of the different Vircell assays in comparison to a validated ELISA (Serion classic ELISA). Clinical sensitivity and specificity were 74.6% and 96.6%, respectively, for the IgM IFA, 65.1% and 88.0% for the IgG IFA, 92.3% and 100% for the IgM ELISA, 43.3% and 96.6% for the IgG ELISA, and 90.8% and 100% for the IgM-plus-IgG ELISA. Compared to Serion classic ELISA, agreement, sensitivity, and specificity were 80.0%, 83.1%, and 78.4%, respectively, for the IgM IFA, 75.2%, 66.0%, and 79.5% for the IgG IFA, 89.5%, 82.0%, and 97.6% for the IgM ELISA, 81.9%, 88.9%, and 78.0% for the IgG ELISA, and 93.5%, 90.0%, and 96.6% for the IgM-plus-IgG ELISA. The value of a positive diagnostic result obtained by the Vircell IgM IFA, the Vircell IgG IFA, and the Vircell IgG ELISA might not be acceptable for a diagnostic assay. Both the high specificities and sensitivities of the Vircell IgM ELISA and the IgM-plus-IgG ELISA and the high correlation with the Serion classic ELISA indicate that they are useful in the diagnosis of LD.  相似文献   

6.
The Binax legionella urinary antigen (LUA) enzyme immunoassay (Binax, Portland, Maine) was evaluated in 159 patients with suspected or proven legionellosis and 209 controls. A positive LUA test was found in 37% of patients with suspected legionellosis overall and in 83% of those with proven Legionella pneumophila serogroup 1 infection. The sensitivity of the LUA test was significantly greater than that of the direct fluorescent-antigen test (83 versus 42%; P < 0.0001) but not significantly different from that of culture (85%) or serology (91%); specificity was at least 99.5%.  相似文献   

7.
An agarose microdroplet technique was utilized to assess the cellular immunity of guinea pig lymphoid cells to Legionella pneumophila antigen in vitro. Both direct and indirect migration inhibition procedures were shown to be capable of detecting sensitization of guinea pigs to L. pneumophila antigens. Animals injected with adjuvant alone or unrelated antigens did not yield spleen cells responsive to L. pneumophila, indicating the specificity of the response. Migration inhibition factor induction by Legionella antigen in vitro correlated well with skin test responses in vivo. The positive reaction detected by migration inhibition occurred at times similar to that of skin reactivity but later than that of the earliest serum antibody titers. The assay appears to be useful for monitoring sensitization to Legionella and may be applicable to the study of cell-mediated immunity to this bacterium in infected individuals.  相似文献   

8.
The antibody response of patients infected with Legionella pneumophila serogroup 1 in a common source outbreak was investigated. Heat-killed antigens from L pneumophila serogroups 1-3 and 6-10, plus several other strains of L pneumophila, together with 13 other species of legionellas were used in an indirect fluorescence antibody test. Formolised yolk sac antigens made from L pneumophila serogroups 1, 6, and 7 were also used. Although antibodies were produced to several L pneumophila serogroups or Legionella species by individuals, there was no constant pattern, suggesting that the response is a characteristic of the infected individual and not of the infecting strain of Legionella. There is evidence that heat-killed antigen made from L pneumophila serogroup 7 may give unreliable results.  相似文献   

9.
An antigen prepared with agar-grown Legionella pneumophila group 1 killed by 0.5% phenol and suspended in 0.5% yolk sac was examined for use in the indirect immunofluorescence test for legionellosis and compared with a heat-killed antigen. The serological results of the two antigens for single and paired sera agreed well. Morphological and staining characteristics were better for phenol-treated organisms. Electron microscopy observation showed an apparently well-preserved cell surface. The background antibody level among a healthy control population was very low (3.4% with titers of greater than or equal to 16). Sera of patients with gram-negative bacteria infections (Yersinia enterocolytica, Campylobacter jejuni, Salmonella typhimurium, Escherichia coli, Brucella melitensis, Pseudomonas aeruginosa, Mycoplasma pneumoniae, Coxiella burnetti, and Chlamydia psittaci) showed no cross-reactions with the phenol-killed antigen. The data suggest that phenol-killed antigen is sensitive and specific. This antigen is stable for at least 1 year.  相似文献   

10.
Members of the genus Legionella are characterized as gram-negative, motile, freshwater-dwelling bacteria that were responsible for a pneumonia outbreak among American Legion members in 1976. Because clinicians routinely order serologic testing for Legionella pneumophila serogroups 1 to 6 as a screen for possible L. pneumophila infections, we evaluated the Wampole Laboratories L. pneumophila type 1 to 6 immunoglobulin G (IgG) and IgM combined enzyme-linked immunosorbent assay (ELISA) and the Zeus Scientific L. pneumophila type 1 to 6 IgG-IgM-IgA multispecific combined ELISA systems and compared them to an IgG-specific immunofluorescence assay (IFA) for L. pneumophila serogroups 1 to 6. The Centers for Disease Control and Prevention recommends that the positive titer cutoff for an IFA be 1:256. Regardless of where the positive IFA cutoff titer is placed, however, the sensitivity of both commercial assays was below what would be acceptable for a screening assay. With a 1:256 IFA titer as the positive cutoff, the agreement, sensitivity, and specificity of the Wampole ELISA were 74.6, 21.4, and 98.4%, respectively. The agreement, sensitivity, and specificity of the Zeus ELISA were 72.6, 10.5, and 100.0%, respectively. We recommend that any laboratories attempting to replace an IFA type 1 to 6 screen with an alternative ELISA carefully investigate the sensitivity of the replacement assay.  相似文献   

11.
The enzyme linked immunosorbent assay (ELISA) described was developed to detect a soluble antigen in the urine of patients with Legionnaires' disease caused by Legionella pneumophila serogroup 1 (L.pn 1). The assay was evaluated and showed good specificity (100%) and intra-assay reproducibility. Antigen was detected in the urine of 93 (77%) of 120 patients, overall, and in 86% of patients from whom a specimen obtained within seven days of onset of illness was available. On all but one occasion the first urine sample taken from a patient for whom a positive ELISA result was obtained, was itself positive. In one case antigen was not detected at four days but was present on the fifth day after onset of symptoms. In two patients urinary antigen was detectable as early as two days after onset of symptoms. In another the antigen persisted for at least 60 days. More than half the patients, however, had stopped producing detectable antigen within 14 days of onset of symptoms. It is therefore important that where Legionnaires' disease is suspected urine is collected as early as possible in the course of the disease.  相似文献   

12.
Patients with Q fever and legionellosis may present identical clinical symptom. Differentiation of these diseases is made by serology, mainly the indirect immunofluorescence assay (IFA). Using IFA the authors tested 154 Q fever positive sera from 55 patients with acute Q fever and 28 patients with chronic Q fever for Legionella pneumophila antibodies and 57 sera from 57 patients with legionellosis for Coxiella burnetii antibodies. Of the 211 sera tested, four sera from different patients had antibodies to both C. burnetii and L. pneumophila. Using cross-adsorption studies and protein immunoblotting, no cross-reaction between C. burnetii and L. pneumophila antibodies could be identified. The moderate antibody titers against L. pneumophila in two Q fever patients and vice versa for one legionellosis patient are consistent with the incidence of seroprevalence in healthy blood donors and were not due to cross-reactivity. One patient was identified with concurrent Q fever and legionellosis.  相似文献   

13.
The diagnostic accuracy of an indirect immunofluorescence antibody test (IFAT) for Strongyloides stercoralis at different serum antibody titers was evaluated. To assess diagnostic sensitivity, sera from 156 patients with known strongyloidiasis were collected. Negative control sera were obtained from a composite group of 427 subjects (blood donors and hospitalized patients). With an area under the receiver-operating characteristic plot of 0.98, the IFAT showed a high level of diagnostic accuracy for strongyloidiasis. An antibody titer of > or = 1:20, with 97% sensitivity and 98% specificity, was identified as the diagnostic threshold with the best overall performance. Cross-reactions were evaluated with 41 additional samples from patients with other known helminth infections, and the IFAT detected low-titer positivity in only one subject with filariasis. A positive IFAT result at an antibody dilution of > or = 1:80 was virtually 100% specific, with 71% sensitivity. To test the usefulness of the IFAT as a monitoring tool, the changes in specific-antibody titers after treatment in a group of 155 patients were evaluated. Seroreversion or a decrease in antibody titer of twofold or more was observed in 60% of the patients. Response to treatment was directly correlated to the initial antibody titer, and a baseline titer of > or = 1:80 was identified as the best predictor of response. In conclusion, a positive IFAT result at an antibody dilution of >/=1:20 is the optimal cutoff for screening. A titer of > or = 1:80, with virtually no false-positive result, is a reliable cutoff for a serological assessment of treatment efficacy and for inclusion in clinical trials.  相似文献   

14.
A new immunochromatographic assay for rapid qualitative detection of Legionella pneumophila serogroup 1 antigen in urine specimens was used during an outbreak of legionellosis in The Netherlands. The assay seems of the utmost value in providing a rapid diagnosis of Legionnaires' disease in patients with severe community-acquired pneumonia in an outbreak setting.  相似文献   

15.
Molecular epidemiology of Legionella pneumophila serogroup 1   总被引:1,自引:14,他引:1       下载免费PDF全文
The DNA of patient and environmental isolates of Legionella pneumophila serogroup 1 was analyzed by restriction endonuclease cleavage. The electrophoretic patterns of the DNA digests of isolates from a group of patients with Legionnaires disease acquired in a hospital were indistinguishable from one another and were identical to the DNA pattern of a strain isolated from the hot water supply of the hospital. On the other hand, they were easily differentiated from strains isolated from patients and hot water supplies in other hospitals in the same city. The homogeneity of populations of L. pneumophila serogroup 1 colonizing plumbing systems was also investigated by DNA restriction endonuclease analysis in three hospitals. We distinguished two subtypes in one hospital; the two other hospitals had homogeneous populations. Restriction endonuclease digest analysis of L. pneumophila serogroup 1 DNA enables subtyping and appears to be a useful method for examining the epidemiology of outbreaks of Legionnaires disease.  相似文献   

16.
This investigation found that individuals with microagglutination antibody titers of 1:32 or greater to Legionella pneumophila produced bactericidal activity against the bacterium. Those individuals with microagglutination antibody titers of 1:16 or less demonstrated no bactericidal activity.  相似文献   

17.
18.
Paired nasopharyngeal aspirate (NPA) and nasopharyngeal swab (NPS) specimens obtained from each of 32 hospitalized infants with X-ray-confirmed pneumonia (91%) or bronchiolitis were tested for respiratory syncytial virus (RSV) infection by virus culture, the indirect immunofluorescent-antibody (IFA) technique, enzyme-linked immunosorbent assay (ELISA; Ortho Diagnostic Systems, Inc.), and spot hybridization with a human genomic probe to quantitate cellular DNA. RSV was isolated in cell cultures from 72% (23 of 32) of patients by using NPA specimens compared with 47% (15 of 32) by using NPS specimens. With tissue culture positivity as the reference test, the sensitivities of the ELISA on NPA and NPS specimens were found to be 69% (16 of 23) and 61% (14 of 23), respectively, with a specificity and a positive predictive value from both sites of 100%. The sensitivities of the IFA technique compared with the cell culture on NPA and NPS specimens were 61% (14 of 23) and 52% (12 of 23) with specificities of 89 and 78% and positive predictive values of 96 and 92%, respectively. Despite the recovery of significantly more cells (as shown by detection of more cellular DNA by using NPA specimens), virus was detected by the IFA technique or ELISA at similar frequencies in paired specimens. However, virus was recovered more often from NPA than NPS specimens by cell culture, and ELISA optical density readings and the number of RSV-positive fluorescing cells were greater for NPA specimens. NPA specimen collection was less traumatic for the patient, was an easier procedure for the physician to perform, and provided a superior laboratory specimen for RSV diagnosis than the NPS technique.  相似文献   

19.
20.
The radioimmunoprecipitation assay (RIPA) has been used as a confirmatory test in several ongoing and published studies of Trypanosoma cruzi in blood donors in the United States. Despite its use as a confirmatory test, few studies are available comparing RIPA to commercially available serologic test methods. Thus, we compared RIPA with two indirect hemagglutination assays (Biolab Diagnostica SA, S?o Paulo, Brazil; Hemagen Diagnostics, Inc., Waltham, Mass.) and four different enzyme-linked immunosorbent assays (Abbott Laboratories, Abbott Park, Ill.; Embrabio, S?o Paulo, Brazil; Organon Teknika, S?o Paulo, Brazil; and Gull Laboratories, Salt Lake City, Utah) using a panel of 220 serum specimens from Brazilian blood donors with a range of T. cruzi antibody titers as determined by indirect immunofluorescence assay (IFA). A titer of 1:20 was used as the baseline for seropositivity. All IFA-negative serum specimens (n = 19) were nonreactive on all tests. At a titer of 1:20 (n = 9), reactivity rates varied considerably among the tests, with only the RIPA and the Organon and Gull assays identifying reactive specimens. For specimens at a 1:40 titer (n = 35), most assays identified at least 32 of 35 (91%) specimens as reactive, but the Biolab assay only identified 24 (69%). At higher titers (1:80, n = 56; 1:160, n = 101) the assays were comparable, with the exception of the Biolab assay, demonstrating rates of agreement with IFA of >/=98%. Overall, when compared with several other test formats, RIPA demonstrated equivalent or superior rates of agreement with IFA-positive specimens across all titers examined. In particular, at titers of >1:40, the RIPA compared favorably with other test methods currently in use, supporting its application as a confirmatory test, particularly in a research setting.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号