The effect of radial head fracture size on elbow kinematics and stability.   总被引:2,自引:0,他引:2  
This study determined the effect of radial head fracture size and ligament injury on elbow kinematics. Eight cadaveric upper extremities were studied in an in vitro elbow simulator. Testing was performed with ligaments intact, with the medial collateral (MCL) or lateral collateral (LCL) ligament detached, and with both the MCL and LCL detached. Thirty degree wedges were sequentially removed from the anterolateral radial head up to 120 degrees . Valgus angulation and external rotation of the ulna relative to the humerus were determined for passive motion, active motion, and pivot shift testing with the arm in a vertical (dependent) orientation. Maximum varus-valgus laxity was calculated from measurements of varus and valgus angulation with the arm in horizontal gravity-loaded positions. No effect of increasing radial head fracture size was observed on valgus angulation during passive and active motion in the dependent position. In supination, external rotation increased with increasing fracture size during passive motion with LCL deficiency and both MCL and LCL deficiency. With intact ligaments, maximum varus-valgus laxity increased with increasing radial head fracture size. With ligament disruption, elbows were grossly unstable, and no effect of increasing radial head fracture size occurred. During pivot shift testing, performed with the ligaments intact, subtle instability was noted after resection of one-third of the radial head. In this in vitro biomechanical study, small subtle effects of radial head fracture size on elbow kinematics and stability were seen in both the ligament intact and ligament deficient elbows. These data suggest that fixation of displaced radial head fractures less than or equal to one-third of the articular diameter may have some biomechanical advantages; however, clinical correlation is required.  相似文献   

2.
The objective of this study was to determine the effect of suture repair of type 1 coronoid fractures on elbow kinematics in ligamentously intact and medial collateral ligament (MCL)-deficient elbows. Cadaveric testing was performed in stable and MCL-deficient elbows with radial head arthroplasty and with the coronoid intact, with the coronoid fractured, and after suture repair. Ulna versus humerus angulation was measured during active motion. Varus and valgus motion pathways were measured during passive gravity-loaded flexion. With intact ligaments, there was a small increase in valgus angulation after a type 1 fracture that was not corrected with suture fixation. With MCL deficiency, there was no change in kinematics regardless of coronoid status. Type 1 coronoid fractures cause only small changes in elbow kinematics that are not corrected with suture repair. MCL repair, rather than type 1 coronoid fixation, should be considered if the elbow remains unstable after radial head repair or replacement and lateral ligament repair.  相似文献   

3.
BACKGROUND: Comminuted radial head fractures associated with an injury of the medial collateral ligament can be treated with a radial head implant. We hypothesized that lengthening and shortening of the radial neck would alter the kinematics and the pressure through the radiocapitellar joint in the medial collateral ligament-deficient elbow. METHODS: The effects of lengthening (2.5 and 5 mm) and shortening (2.5 and 5 mm) of the radial neck were assessed in six human cadaveric upper extremities in which the medial collateral ligament had been surgically released. The three-dimensional spatial orientation of the ulna was recorded during simulated active motion from extension to flexion. Total varus-valgus laxity and ulnar rotation were measured. Radiocapitellar joint pressure was assessed with use of pressure-sensitive film. RESULTS: Radial neck lengthening or shortening of >/=2.5 mm significantly changed the kinematics in the medial collateral ligament-deficient elbow. Lengthening caused a significant decrease (p < 0.05) in varus-valgus laxity and ulnar rotation (p < 0.05), with the ulna tracking in varus and external rotation. Shortening caused a significant increase in varus-valgus laxity (p < 0.05) and ulnar rotation (p < 0.05), with the ulna tracking in valgus and internal rotation. The pressure on the radiocapitellar joint was significantly increased after 2.5 mm of lengthening. CONCLUSIONS: This study suggests that accurate restoration of radial length is important and that axial understuffing or overstuffing of the radiohumeral joint by >/=2.5 mm alters both elbow kinematics and radiocapitellar pressure. CLINICAL RELEVANCE: This in vitro cadaver study indicates that a radial head replacement should be performed with the same level of concern for accuracy and reproducibility of component position and orientation as is appropriate with any other prosthesis.  相似文献   

4.
重建肘关节外翻稳定性的生物力学研究   总被引:4,自引:1,他引:3  
目的 评价肘关节桡骨头 (radial head,RH)切除、尺侧副韧带 (medial collateral ligament,MCL )损伤以及 RH假体置换、MCL重建后的外翻稳定性。 方法 新鲜成人尸体上肢标本 12侧 ,制成肘关节“骨 -韧带”标本 ,在2 N· m的外翻力矩作用下 ,分别在肘关节 0°、30°、6 0°、90°和 12 0°伸屈时 ,测量肘关节外翻松弛度 :1完整肘关节(n=12 ) ;2 MCL切断 (n=6 ) ;3RH切除 (n=6 ) ;4 MCL切断 +RH切除 (n=12 ) ;5 RH假体置换 (n=6 ) ;6 MCL重建(n=6 ) ;7RH假体置换 +MCL重建 (n=12 )。用 SPSS 10 .0统计软件包作方差分析 ,比较各组的外翻稳定性。 结果 完整肘关节的平均外翻松弛度最小 ;RH切除后 ,外翻松弛度增大 ;单纯 MCL切断 ,外翻松弛度大于单纯 RH切除 (P<0 .0 1) ;MCL切断 +RH切除 ,外翻稳定性最差 ;行 RH假体置换 ,对稳定性有改善 ;MCL重建与完整 MCL差异无统计学意义 (P>0 .0 5 ) ;RH假体置换同时重建 MCL ,效果最好。 结论  MCL是抵抗肘关节外翻应力最主要的因素 ,RH是次要因素。在重建肘关节的外翻稳定性方面 ,MCL的重建比 RH的假体置换更重要。在无条件行 RH假体置换时 ,修复MCL是较好的手术方式。  相似文献   

5.
BACKGROUND: The purpose of this study was to evaluate the stabilizing effect of radial head replacement in cadaver elbows with a deficient medial collateral ligament. METHODS: Passive elbow flexion with the forearm in neutral rotation and in 80 degrees of pronation and supination was performed under valgus and varus loads (1) in intact elbows, (2) after a surgical approach (lateral epicondylar osteotomy of the distal part of the humerus), (3) after release of the anterior bundle of the medial collateral ligament, (4) after release of the anterior bundle of the medial collateral ligament and resection of the radial head, and (5) after subsequent replacement of the radial head with each of three different types of radial head prostheses (a Wright monoblock titanium implant, a KPS bipolar Vitallium [cobalt-chromium]-polyethylene implant, and a Judet bipolar Vitallium-polyethylene-Vitallium implant) in the same cadaver elbow. Total valgus elbow laxity was quantified with use of an electromagnetic tracking device. RESULTS: The mean valgus laxity changed significantly (p < 0.001) as a factor of constraint alteration. The greatest laxity was observed after release of the medial collateral ligament together with resection of the radial head (11.1 degrees +/- 5.6 degrees). Less laxity was seen following release of the medial collateral ligament alone (6.8 degrees +/- 3.4 degrees), and the least laxity was seen in the intact state (3.4 degrees +/- 1.6 degrees). Forearm rotation had a significant effect (p = 0.003) on valgus laxity throughout the range of flexion. The laxity was always greater in pronation than it was in neutral rotation or in supination. The mean valgus laxity values for the elbows with a deficient medial collateral ligament and an implant were significantly greater than those for the medial collateral ligament-deficient elbows before radial head resection (p < 0.05). The implants all performed similarly except in neutral forearm rotation, in which the elbow laxity associated with the Judet implant was significantly greater than that associated with the other two implants. CONCLUSIONS AND CLINICAL RELEVANCE: This study showed that a bipolar radial head prosthesis can be as effective as a solid monoblock prosthesis in restoring valgus stability in a medial collateral ligament-deficient elbow. However, none of the prostheses functioned as well as the native radial head, suggesting that open reduction and internal fixation to restore radial head anatomy is preferable to replacement when possible.  相似文献   

6.
Metallic radial head arthroplasty improves valgus stability of the elbow   总被引:15,自引:0,他引:15  
The stabilizing influence of radial head arthroplasty was studied in eight medial collateral ligament deficient anatomic specimen elbows. An elbow testing apparatus, which used computer controlled pneumatic actuators to apply tendon loading, was used to simulate active elbow flexion. The motion pathways of the elbow were measured using an electromagnetic tracking device, with the forearm in supination and pronation. As a measure of stability, the maximum varus to valgus laxity over the range of elbow flexion was determined from the difference between varus and valgus gravity loaded motion pathways. After transection of the medial collateral ligament, the radial head was excised and replaced with either a silicone or one of three metallic radial head prostheses. Medial collateral ligament transection caused a significant increase in the maximum varus to valgus laxity to 18.0 degrees +/- 3.2 degrees. After radial head excision, this laxity increased to 35.6 degrees +/- 10.3 degrees. The silicone implant conferred no increase in elbow stability, with a maximum varus to valgus laxity of 32.5 degrees +/- 15.5 degrees. All three metallic implants improved the valgus stability of the medial collateral ligament deficient elbow, providing stability similar to the intact radial head. The use of silicone arthroplasty to replace the radial head in the medial collateral ligament deficient elbow must be questioned. Metallic radial head arthroplasty provides improved valgus stability, approaching that of an intact radial head.  相似文献   

7.
The GSB III elbow prosthesis is a loose-hinged type of elbow implant. The introduction of such hinged elbow arthroplasty expanded the indications for elbow replacement to patients with more deficient bone and ligaments. The purpose of this study was to compare the kinematics and stability of the GSB III elbow prosthesis with that of the normal elbow and to investigate the role of the collateral ligaments in the kinematics and the stability of the GSB III total elbow prosthesis in an in vitro model. The results could show a semiconstrained kinematic pattern of the GSB III implant. The mean laxity for varus/valgus stress of the implant without collateral ligament support was significantly greater for all flexion angles when compared with intact elbows (mean, 12.7 degrees versus 5.4 degrees ) and with elbows treated with a standard implantation technique (mean, 9.5 degrees ). The release of the collateral ligaments increased the already observed varus shift after standard implantation of a GSB III elbow prosthesis. The laxity measured without collateral ligaments during loaded movement reached the maximum varus/valgus laxity of the GSB III prosthesis of 12 degrees degrees. The study confirms the role of the collateral ligaments in stabilizing the GSB III elbow prosthesis. Missing collateral ligaments may overload the implant-cement-bone interface and may be one factor contributing to early aseptic loosening of this device.  相似文献   

8.
A widely used clinical recommendation is that in the presence of medial collateral ligament injuries, two-part radial head fractures should be fixed rather than excising or replacing the radial head. Direct biomechanical data comparing fracture fixation, radial head replacement and excision in a human cadaveric elbow model, have not been previously described. Such comparison is clinically important as with the increasing availability of radial head implants and promising follow up results, the role of radial head replacement in fracture management may have to be redefined. In this study, five fresh cadaveric elbows had radial head fracture creation and medial collateral ligament division, fracture fixation, radial head replacement and excision. Valgus and varus laxity were determined using an electromagnetic tracking system. Radial head replacement leads to a similar valgus (P=0.80) [corrected] laxity as compared to radial head fixation. Radial head excision resulted in a significantly greater valgus laxity as compared to radial head fixation (P=0.02) or replacement (P=0.03). Both radial head excision and replacement led to a greater varus laxity as compared to fixation. Our results suggest that in the elbow with medial collateral ligament injury and two-part radial head fracture, fixation is overall biomechanically superior as compared to replacement and excision.  相似文献   

9.
BACKGROUND: The lateral ulnar collateral ligament, the entire lateral collateral ligament complex, and the overlying extensor muscles have all been suggested as key stabilizers against posterolateral rotatory instability of the elbow. The purpose of this investigation was to determine whether either an intact radial collateral ligament alone or an intact lateral ulnar collateral ligament alone is sufficient to prevent posterolateral rotatory instability when the annular ligament is intact. METHODS: Sequential sectioning of the radial collateral and lateral ulnar collateral ligaments was performed in twelve fresh-frozen cadaveric upper extremities. At each stage of the sectioning protocol, a pivot shift test was performed with the arm in a vertical position. Passive elbow flexion was performed with the forearm maintained in either pronation or supination and the arm in the varus and valgus gravity-loaded orientations. An electromagnetic tracking device was used to quantify the internal-external rotation and varus-valgus angulation of the ulna with respect to the humerus. RESULTS: Compared with the intact elbow, no differences in the magnitude of internal-external rotation or maximum varus-valgus laxity of the ulna were detected with only the radial collateral or lateral ulnar collateral ligament intact (p > 0.05). However, once the entire lateral collateral ligament was transected, significant increases in internal-external rotation (p = 0.0007) and maximum varus-valgus laxity (p < 0.0001) were measured. None of the pivot shift tests had a clinically positive result until the entire lateral collateral ligament was sectioned. CONCLUSIONS: This study suggests that, when the annular ligament is intact, either the radial collateral ligament or the lateral ulnar collateral ligament can be transected without inducing posterolateral rotatory instability of the elbow.  相似文献   

10.
Because of a lack of biomechanical studies of lateral elbow ligament reconstruction in the literature, the initial stability afforded by 3 different techniques of lateral ulnar collateral ligament reconstruction was evaluated in 8 cadaveric elbows. The arm was mounted in a testing apparatus, and passive flexion was performed with the arm in varus and valgus orientations. A pivot shift test was performed with the arm in the vertical orientation. An electromagnetic tracking device was used to quantify motion pathways. After intact testing, each specimen underwent sectioning of the radial collateral and lateral ulnar collateral ligaments from the lateral epicondyle. Reconstruction of the lateral ulnar collateral ligament was performed in a randomized sequence, consisting of proximal single-strand, distal single-strand, and double-strand tendon grafts. Division of the radial collateral and lateral ulnar collateral ligaments from the lateral epicondyle caused a significant decrease in rotational stability when the pivot shift test was being performed (P <.0001). Varus-valgus stability also decreased after transection of the radial collateral and lateral ulnar collateral ligaments (P <.0001). Reconstruction of the lateral ulnar collateral ligament restored elbow stability to that of the intact state. There was no significant difference in stability between the single- and double-strand repair techniques (P >.05). This study demonstrates that both single- and double-strand reconstructions restore varus and posterolateral elbow stability and may be considered appropriate reconstructive procedures in patients with symptomatic insufficiency of the lateral ligaments of the elbow.  相似文献   

11.
BACKGROUND: The purpose of this study was to evaluate the role of the radial head and the coronoid process as posterolateral rotatory stabilizers of the elbow and to determine the stabilizing effect of radial head replacement and coronoid reconstruction. METHODS: The posterolateral rotatory displacement of the ulna was measured after application of a valgus and supinating torque (1). in seven intact elbows, (2). after radial head excision, (3). after sequential resection of the coronoid process, (4). after subsequent insertion of each of two different types of metal radial head prostheses (a rigid implant and a bipolar implant with a floating cup), and (5). after subsequent reconstruction of the coronoid with each of two different techniques in the same cadaveric elbow. RESULTS: The posterolateral rotatory laxity averaged 5.4 degrees in the intact elbows. The surgical approach used in this study insignificantly increased the mean laxity to 9 degrees. Excision of the radial head in an elbow with intact collateral ligaments caused a mean posterolateral rotatory laxity of 18.6 degrees (p < 0.0001). Additional removal of 30% of the height of the coronoid fully destabilized the elbows, always resulting in ulnohumeral dislocation despite intact ligaments. Implantation of a rigid radial head prosthesis stabilized the elbows. However, a mean laxity of 16.9 degrees persisted after insertion of a floating prosthesis (p < 0.0001). The elbows with a defect of 50% or 70% of the coronoid, loss of the radial head, and intact ligaments could not be stabilized by radial head replacement alone, but additional coronoid reconstruction restored stability. CONCLUSIONS: The results of this study suggest that the coronoid and the radial head contribute significantly to posterolateral rotatory stability.  相似文献   

12.
The stabilizing structures of the elbow that resist valgus stress were studied with a tracking device in a model simulating active motion and muscle activity. By varying the order of serial release of the medial collateral ligament complex and removal of the radial head, each structure's contribution to valgus stability against the effect of gravity was determined. In the otherwise intact elbow, absence of the radial head does not significantly alter the three-dimensional characteristics of motion in the elbow joint. Isolated medial collateral release, on the other hand, causes increases in abduction rotation of about 6 degrees-8 degrees in magnitude. Releasing both structures results in gross abduction laxity and elbow subluxation. This study defines the medial collateral ligament (MCL) as the primary constraint of the elbow joint to valgus stress and the radial head as a secondary constraint. This definition facilitates the proper management of patients with radial head fractures and MCL disruption. The comminuted radial head fracture uncomplicated by MCL insufficiency should be treated by excision without the need for an implant and without concern of altering the normal kinematics of the elbow.  相似文献   

13.
We investigated the effect of simulated muscle loading and the contribution of the radial head to stability of the Norway elbow in 6 cadavers using an electromagnetic tracking device. The kinematics of the elbow after implantation of the prosthesis were similar to the intact elbow in their valgus-varus orientation, however, the forearms were slightly externally rotated, probably due to a small amount of external rotation of the humeral components at the time of implantation. The valgus-varus laxity limit of the implants were greater than in the intact specimens averaging 8.0 and 5.6 degrees, respectively. Simulated muscle loading stabilized both the intact and the Norway elbows. Excision of the radial head after implant arthroplasty increased their valgus-varus laxity, suggesting that preservation of the radial head may be indicated if it is not too severely involved by the underlying disease process.

The laxity permitted by the prosthesis articulation is greater than that measured after implantation of the Norway arthroplasty. This suggests that the prosthesis may behave as an unconstrained arthroplasty. This should minimize the stress experienced by the bone-cement interface and may reduce the incidence of loosening. The laxity of the elbows after joint arthroplasty were only slightly greater than normal, possibly explaining the low incidence of prosthesis dislocation which has been observed with clinical use.  相似文献   

14.
We studied the stabilising effect of prosthetic replacement of the radial head and repair of the medial collateral ligament (MCL) after excision of the radial head and section of the MCL in five cadaver elbows. Division of the MCL increased valgus angulation (mean 3.9 +/- 1.5 degrees) and internal rotatory laxity (mean 5.3 +/- 2.0 degrees). Subsequent excision of the radial head allowed additional valgus (mean 11.1 +/- 7.3 degrees) and internal rotatory laxity (mean 5.7 +/- 3.9 degrees). Isolated replacement of the radial head reduced valgus laxity to the level before excision of the head, while internal rotatory laxity was still greater (2.8 +/- 2.1 degrees). Isolated repair of the MCL corrected internal rotatory laxity, but a slight increase in valgus laxity remained (mean 0.7 +/- 0.6 degrees). Combined replacement of the head and repair of the MCL restored stability completely. We conclude that the radial head is a constraint secondary to the MCL for both valgus displacement and internal rotation. Isolated repair of the ligament is superior to isolated prosthetic replacement and may be sufficient to restore valgus and internal rotatory stability after excision of the radial head in MCL-deficient elbows.  相似文献   

15.
The objectives of this experimental study were to investigate the effect of radial head excision and lateral collateral ligament (LCL) division on elbow joint laxity and to determine the efficacy of radial head prosthetic replacement and LCL repair. Valgus, varus, internal rotation, and external rotation of the ulna were measured during passive flexion-extension and application of a 0.75-Nm torque in 6 intact cadaveric elbows and after (1) either excision of the radial head or division of the LCL, (2) removal of both constraints, (3) isolated radial head prosthetic replacement, (4) isolated LCL repair, and (5) radial head replacement combined with LCL repair. Isolated radial head excision increased varus (mean, 4.8 degrees) and external rotatory laxity (mean, 7.1 degrees), as did isolated LCL division (mean, 14.1 degrees for varus; mean, 14.7 degrees for external rotation). After removal of both constraints, varus and external rotatory laxities were increased by 19.0 degrees and 20.1 degrees, respectively, compared with the intact specimens. Isolated radial head replacement reduced mean varus laxity to 14.6 degrees and mean external rotatory laxity to 14.8 degrees. Isolated LCL repair normalized varus laxity but resulted in a 2.9 degrees increase in external rotatory laxity. The combined procedures restored laxity completely. The radial head is a constraint to varus and external rotation in the elbow joint, functioning by maintaining tension in the LCL. Still, removal of both constraints induces severe laxity, and in this case, prosthetic replacement may substitute for the constraining capacity of the native radial head. The combination of LCL repair and radial head replacement restores laxity completely, but an isolated LCL repair performs almost as well, probably by compensating for the ligamentous tension lost from radial head excision.  相似文献   

16.
Forty intact cadaver elbows were studied to determine the contribution of the capitellum to elbow stability. With the elbow at 10 degrees of flexion, valgus motion of the elbow after capitellum excision demonstrated a minimal increase. Although some increase in valgus motion did occur after capitellum excision and radial head resection it was not until the ulnar collateral ligament was released that a severe valgus deformity was produced. In addition, isolated capitellum excisions occurring with release of the medial collateral ligament produced severe valgus motion, demonstrating the importance of medial structures to elbow stability. The cadaver study suggests excision of the capitellum in the otherwise intact elbow has little effect on valgus motion. Over the past 15 years, 17 patients with fractures of the capitellum were treated. Followup at greater than 1 year utilizing various treatment modalities is reported. Although closed reduction gave the best result, acceptable results were also obtained by open reduction and internal fixation and excision. Our clinical findings corroborated the cadaver findings in that valgus instability of the elbow only occurred when fracture of the capitellum was associated with medial ligament injuries.  相似文献   

17.
A computational model capable of predicting the effects of lateral collateral ligament deficiency of the elbow joint would be a valuable tool for surgical planning and prediction of the long‐term consequences of ligament deficiency. The purpose of this study was to simulate lateral collateral ligament deficiency during passive flexion using a computational multibody elbow joint model and investigate the effects of ligament insufficiency on the kinematics, ligament loads, and articular contact characteristics (area, pressure). The elbow was placed initially at approximately 20° of flexion and a 345 mm vertical downward motion profile was applied over 40 s to the humerus head. The vertical displacement induced flexion from the initial position to a maximum flexion angle of 135°. The study included simulations for intact, radial collateral ligament deficient, lateral ulnar collateral ligament deficient, and combined radial and lateral ulnar collateral ligament deficient elbow. For each condition, relative bone kinematics, contact pressure, contact area, and intact ligament forces were predicted. Intact and isolated radial collateral ligament deficient elbow simulations were almost identical for all observed outcomes. Minor differences in kinematics, contact area and pressure were observed for the isolated lateral ulnar collateral ligament deficient elbow compared to the intact elbow, but no elbow dislocation was detected. However, sectioning both ligaments together induced substantial differences in kinematics, contact area, and contact pressure, and caused complete dislocation of the elbow joint. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1645–1655, 2016.  相似文献   

18.
In this study the kinematics of partial and total ruptures of the medial collateral ligament of the elbow are investigated. After selective transection of the medial collateral ligament of 8 osteoligamentous intact elbow preparations was performed, 3-dimensional measurements of angular displacement, increase in medial joint opening, and translation of the radial head were examined during application of relevant stress. Increase in joint opening was significant only after complete transection of the anterior part of the medial collateral ligament was performed. The joint opening was detected during valgus and internal rotatory stress only. After partial transection of the anterior bundle of the medial collateral ligament was performed, there was an elbow laxity to valgus and internal rotatory force, which became significant after transection of 100% of the anterior bundle of the medial collateral ligament and was maximum between 70 degrees to 90 degrees of flexion. No radial head movement was seen after partial or total transection of the anterior bundle of the medial collateral ligament was performed. In conclusion, this study indicates that valgus or internal rotatory elbow instability should be evaluated at 70 degrees to 90 degrees of flexion. Detection of partial ruptures in the anterior bundle of the medial collateral ligament based on medial joint opening and increased valgus movement is impossible.  相似文献   

19.

Background

Monopolar and bipolar radial head prosthetic arthroplasties have been used successfully to treat elbow fracture-dislocation with unsalvageable radial head fractures. The relative stability of these two designs in different clinical situations is a topic of ongoing investigation.

Questions/purposes

We tested the effects of monopolar and bipolar fixed-neck prosthetic radial head implants on improvement in elbow coronal and axial plane laxity in a terrible triad biomechanical model that accounted for lateral collateral ligament integrity and the presence of a transverse coronoid fracture.

Methods

Kinematic data were collected on six fresh-frozen cadaveric upper extremities tested with passive motion throughout the flexion arc. Varus and valgus gravity stress were applied with the wrist in neutral position. A lateral collateral ligament reconstruction was simulated. We assessed instability after radial head resection and reconstruction with either a monopolar or bipolar implant in the presence of a transversely fractured (Regan and Morrey Type 2) or fixed coronoid process.

Results

With collateral ligament integrity, no difference was detected, with the numbers available, in valgus laxity between implants under valgus stress (p = 1.0). Laxity improvement with each prosthesis was higher when the coronoid was fractured (mean ± SD: monopolar: 7.4° ± 1.6°, p < 0.001; bipolar: 6.4° ± 1.6°, p = 0.003) than when it was fixed (monopolar: 4.0° ± 1.6°, p = 0.02; bipolar: 4.2° ± 1.6°, p = 0.01). With the numbers available, there was no difference in external rotation laxity between implants under valgus stress (p = 1.0). The greatest stabilizing effect of the prostheses occurred when the coronoid was fractured (monopolar: 3.3° ± 1.2°, p = 0.15; bipolar: 3.3° ± 1.2°, p = 0.17). Radial head arthroplasty offered no substantial stability under varus stress for varus or internal rotation laxity.

Conclusions

In our terrible triad cadaveric model, coronoid fixation was effective in improving varus laxity with a monopolar or bipolar prosthesis in place. Also, both types of prostheses were effective in improving valgus and external rotation laxity to the elbow, regardless of coronoid status. With collateral ligaments reconstructed, no large kinematic differences were noted between implants regardless of the varus-valgus position or whether the coronoid was fractured or fixed.

Clinical Relevance

The data from our cadaveric model support the use of either implant type in terrible triad injuries if the collateral ligaments are intact or reconstructed.  相似文献   

20.
The effects of a radial head component on total elbow arthroplasty kinematics and stability were evaluated using an anatomic design unlinked total elbow prosthesis. An electromagnetic tracking device recorded motion and varus and valgus displacements under various conditions in 10 cadaveric elbows. The motion patterns of the intact elbows and the Sorbie-Questor total elbow prostheses with a radial head component were similar, as both tended to have a valgus position in extension, varus at midflexion, and more valgus toward full flexion. Under conditions of simulated muscle loading, the maximum valgus and varus laxity of the elbow prosthesis was, on average, 8.6 degrees +/- 4.0 degrees greater than normal. Without the radial head component, however, significant kinematic disturbances and instabilities were seen. The varus and valgus displacements were 13.3 degrees +/- 5.5 degrees greater than the intact elbows. One total elbow arthroplasty without a radial head dislocated during testing. Increasing the muscle loading across the elbow significantly enhanced dynamic stability of the total elbow arthroplasties, especially in the extension half of elbow motion where instability is greatest. However, this dynamic enhancement of stability was seen only in those elbows in which the radial head component had been implanted. The radial head component is an important stabilizer, particularly in extension for this prosthesis, and possibly for other unlinked total elbow prostheses. Although instability of unlinked prostheses depends on the prosthetic design, the use of a radial head replacement may be an important factor in preventing such instability. Perhaps even more importantly, a radial head component balances the load distribution across the articulation, which could decrease stress on the ulnohumeral articulation and therefore possibly reduce polyethylene wear, osteolysis, and loosening.  相似文献   