共查询到20条相似文献,搜索用时 0 毫秒
1.
Jonathan P. Walter Darryl D. D'Lima Clifford W. Colwell Jr Benjamin J. Fregly 《Journal of orthopaedic research》2010,28(10):1348-1354
Excessive contact force is believed to contribute to the development of medial compartment knee osteoarthritis. The external knee adduction moment (KAM) has been identified as a surrogate measure for medial contact force during gait, with an abnormally large peak value being linked to increased pain and rate of disease progression. This study used in vivo gait data collected from a subject with a force‐measuring knee implant to assess whether KAM decreases accurately predict corresponding decreases in medial contact force. Changes in both quantities generated via gait modification were analyzed statistically relative to the subject's normal gait. The two gait modifications were a “medial thrust” gait involving knee medialization during stance phase and a “walking pole” gait involving use of bilateral walking poles. Reductions in the first (largest) peak of the KAM (32–33%) did not correspond to reductions in the first peak of the medial contact force. In contrast, reductions in the second peak and angular impulse of the KAM (15–47%) corresponded to reductions in the second peak and impulse of the medial contact force (12–42%). Calculated reductions in both KAM peaks were highly sensitive to rotation of the shank reference frame about the superior–inferior axis of the shank. Both peaks of medial contact force were best predicted by a combination of peak values of the external KAM and peak absolute values of the external knee flexion moment (R2 = 0.93). Future studies that evaluate the effectiveness of gait modifications for offloading the medial compartment of the knee should consider the combined effect of these two knee moments. Published by Wiley Periodicals, Inc. J Orthop Res 28:1348–1354, 2010 相似文献
2.
Roda RD Wilson JL Wilson DA Richardson G Dunbar MJ 《The Journal of arthroplasty》2012,27(6):1244-1250
Computer-assisted surgery can be used to measure 3-dimensional knee function during arthroplasty surgery; however, it is unknown if the movement of the knee measured during surgery is related to the in vitro, dynamic state of the knee joint, specifically the knee adduction moment during gait, which has been related to implant migration. The purpose of this study was to determine if the preoperative adduction moment is correlated with the knee abduction/adduction angle measured intraoperatively. A statistically significant correlation was found between the mean (r(2) = 0.59; P = .001) and peak (r(2) = 0.53; P = .003) preoperative knee adduction moment and the mean abduction/adduction angle measured intraoperatively. The association found in this study suggests the potential for incorporating functional information that relates to surgical outcome into surgical decision making using computer-assisted surgery. 相似文献
3.
General scheme to reduce the knee adduction moment by modifying a combination of gait variables 下载免费PDF全文
Julien Favre Jennifer C. Erhart‐Hledik Eric F. Chehab Thomas P. Andriacchi 《Journal of orthopaedic research》2016,34(9):1547-1556
Reducing the knee adduction moment (KAM) is a promising treatment for medial compartment knee osteoarthritis (OA). Although several gait modifications to lower the KAM have been identified, the potential to combine modifications and individual dose‐responses remain unknown. This study hypothesized that: (i) there is a general scheme consisting of modifications in trunk sway, step width, walking speed, and foot progression angle that reduces the KAM; (ii) gait modifications can be combined; and (iii) dose‐responses differ among individuals. Walking trials with simultaneous modifications in step width, walking speed, progression angle, and trunk sway were analyzed for 10 healthy subjects. Wider step width, slower speed, toeing‐in, and increased trunk sway resulted in reduced first KAM peak, whereas wider step width, faster speed, and increased trunk sway reduced the KAM angular impulse. Individual regressions accurately modeled the amplitude of the KAM variables relative to the amplitude of the gait modification variables, while the dose‐responses varied strongly among participants. In conclusion, increasing trunk sway, increasing step width, and toeing‐in are three gait modifications that could be combined to reduce KAM variables related to knee OA. Results also indicated that some gait modifications reducing the KAM induced changes in the knee flexion moment possibly indicative of an increase in knee loading. Taken together with the different dose‐responses among subjects, this study suggested that gait retraining programs should consider this general scheme of modifications with individualization of the modification amplitudes. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1547–1556, 2016. 相似文献
4.
Allison L. Kinney Thor F. Besier Amy Silder Scott L. Delp Darryl D. D'Lima Benjamin J. Fregly 《Journal of orthopaedic research》2013,31(3):434-440
Knee osteoarthritis (OA) commonly occurs in the medial compartment of the knee and has been linked to overloading of the medial articular cartilage. Gait modification represents a non‐invasive treatment strategy for reducing medial compartment knee force. The purpose of this study was to evaluate the effectiveness of a variety of gait modifications that were expected to alter medial contact force. A single subject implanted with a force‐measuring knee replacement walked using nine modified gait patterns, four of which involved different hiking pole configurations. Medial and lateral contact force at 25, 50, and 75% of stance phase, and the average value over all of stance phase (0–100%), were determined for each gait pattern. Changes in medial and lateral contact force values relative to the subject's normal gait pattern were determined by a Kruskal–Wallis test. Apart from early stance (25% of stance), medial contact force was most effectively reduced by walking with long hiking poles and wide pole placement, which significantly reduced medial and lateral contact force during stance phase by up to 34% (at 75% of stance) and 26% (at 50% of stance), respectively. Although this study is based on data from a single subject, the results provide important insight into changes in medial and lateral contact forces through gait modification. The results of this study suggest that an optimal configuration of bilateral hiking poles may significantly reduce both medial and lateral compartment knee forces in individuals with medial knee osteoarthritis. © 2012 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31: 434–440, 2013 相似文献
5.
Dong Zhao Scott A Banks Darryl D D'Lima Clifford W Colwell Benjamin J Fregly 《Journal of orthopaedic research》2007,25(5):593-602
Though asymmetric loading between the medial and lateral compartments of total knee replacements may contribute to implant loosening and failure, the in vivo contact force distribution during dynamic daily activities remains unknown. This study reports in vivo medial and lateral contact forces experienced by a well-aligned knee implant for a variety of activities. In vivo implant motion and total axial load data were collected from a single knee replacement patient performing treadmill gait (hands resting on handlebars), step up/down, lunge, and kneel activities. In vivo motion was measured using video fluoroscopy, while in vivo axial loads were collected simultaneously using an instrumented tibial component. An elastic foundation contact model employing linear and nonlinear polyethylene material properties was constructed to calculate medial and lateral contact forces based on the measured kinematics, total axial loads, and centers of pressure. For all activities, the predicted medial and lateral contact forces were insensitive to the selected material model. The percentage of medial to total contact force ranged from 18 to 60 for gait, 47 to 65 for step up/down, and 55 to 60 for kneel and lunge. At maximum load during the motion cycle, medial force was 1.2 BW for gait and 2.0 BW for step up/down, while the corresponding lateral forces were 1.0 and 1.5 BW, respectively. At mean load in the final static pose, medial force was 0.2 BW for kneel and 0.9 BW for lunge, with corresponding lateral forces of 0.1 and 0.7 BW, respectively. For this patient, a constant load split of 55% medial-45% lateral during loaded activity would be a reasonable approximation for these test conditions. 相似文献
6.
《Journal of orthopaedic research》2017,35(10):2251-2259
7.
Amir Haim Alon Wolf Guy Rubin Yulya Genis Mona Khoury Nimrod Rozen 《Journal of orthopaedic research》2011,29(11):1668-1674
The knee adduction moment (KAM) provides a major contribution to the elevated load in the medial compartment of the knee. An abnormally high KAM has been linked with the progression of knee osteoarthritis (OA). Footwear‐generated biomechanical manipulations reduce the magnitude of this moment by conveying a more laterally shifted trajectory of the foot's center of pressure (COP), reducing the distance between the ground reaction force and the center of the knee joint, thus lowering the magnitude of the torque. We sought to examine the outcome of a COP shift in a cohort of female patients suffering from medial knee OA. Twenty‐two female patients suffering from medial compartment knee OA underwent successive gait analysis testing and direct pedobarographic examination of the COP trajectory with a foot‐worn biomechanical device allowing controlled manipulation of the COP. Modulation of the COP coronal trajectory from medial to lateral offset resulted in a significant reduction of the KAM. This trend was demonstrated in subjects with mild‐to‐moderate OA and in patients suffering from severe stages of the disease. Our results indicate that controlled manipulation of knee coronal kinetics in individuals suffering from medial knee OA can be facilitated by customized COP modification. © 2011 Orthopaedic Research Society Published by Wiley Periodicals, Inc. J Orthop Res 29:1668–1674, 2011 相似文献
8.
Immediate and short‐term effects of real‐time knee adduction moment feedback on the peak and cumulative knee load during walking 下载免费PDF全文
The peak external knee adduction moment (pKAM), KAM impulse, and peak knee flexion moment (pKFM) during gait are important loading variables in medial tibiofemoral osteoarthritis. We evaluated the effects of gait modification, using real‐time pKAM visual feedback, on pKAM, KAM impulse, and pKFM; and whether participants could maintain the KAM‐reducing gait after feedback removal. Eleven healthy individuals performed a series of walking trials on a split‐belt instrumented treadmill under four conditions of Baseline, Feedback, No Feedback Early, and No Feedback Late. Guided by real‐time feedback of pKAM, they modified their gait patterns to lower pKAM by 20%. Three‐dimensional joint kinematics/kinetics during each walking condition were recorded by a 12‐camera motion capture system and the instrumented treadmill. Change in each knee loading parameter from baseline across conditions was assessed using one‐way repeated‐measures analysis‐of‐variances. In the feedback limb, successful 20% reductions from baseline in pKAM and KAM impulse were achieved across all three conditions. There was a trend for concomitant pKFM increases, partially attenuating the beneficial effects of pKAM reduction. A carry‐over effect of KAM reduction in the non‐feedback limb was noted. The altered gait patterns were participant‐specific and multi‐modal; each participant reported a combination of two to three gait modification strategies used for pKAM reduction. Toe‐in and medial foot contact were the most reported strategies. The findings support the real‐time pKAM visual feedback as a tool for individualized gait modification to reduce knee load. Future studies to evaluate its effectiveness in persons with or at risk for medial knee osteoarthritis is warranted. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:397–404, 2018. 相似文献
9.
BackgroundThe knee adduction moment (KAM) is considered an index for estimating the knee mechanical load, and increased KAM peak and KAM impulse are related to increased medial knee load and progression of knee joint degeneration. We aimed to verify the biomechanical factors of gait related to medial knee loading in patients 6 months after TKA.MethodsThirty-nine women who underwent TKA were enrolled. A three-dimensional gait analysis was performed 6 months postoperatively to generate data on the lower limb joint angle, moment, and power at the backward component (braking phase) and forward component (propulsion phase) peaks of the ground reaction force. Medial knee loading was evaluated using the time-integrated value of KAM during the stance period (KAM impulse). The higher the value of the KAM impulse, the higher the medial knee joint load. The relationships between the KAM impulse and the data for biomechanical factors were evaluated using partial correlation analysis with gait speed as a control factor.ResultsIn the braking phase, the KAM impulse positively correlated with the knee adduction angle (r = 0.377) and negatively correlated with the toe-out angle (r = −0.355). The KAM impulse positively correlated with the knee adduction angle (r = 0.402), the hip flexion moment (r = 0.335), and the hip adduction moment (r = 0.565) and negatively correlated with the toe-out angle (r = −0.357) in the propulsive phase.ConclusionThe KAM impulse 6 months after TKA was related to the knee adduction angle, hip flexion moment, hip adduction moment, and toe-out angle. These findings may provide fundamental data for controlling variable medial knee joint load after TKA and implementing patient management strategies to ensure implant durability. 相似文献
10.
Changes in the total knee joint moment in patients with medial compartment knee osteoarthritis over 5 years 下载免费PDF全文
Jessica L. Asay Jennifer C. Erhart‐Hledik Thomas P. Andriacchi 《Journal of orthopaedic research》2018,36(9):2373-2379
11.
Erhart-Hledik JC Elspas B Giori NJ Andriacchi TP 《Journal of orthopaedic research》2012,30(4):514-521
This study investigated the load‐modifying and clinical efficacy of variable‐stiffness shoes after 12 months in subjects with medial compartment knee osteoarthritis. Subjects who completed a prior 6‐month study were asked to wear their assigned constant‐stiffness control or variable‐stiffness intervention shoes during the remainder of the study. Changes in peak knee adduction moment, total Western Ontario and McMaster Universities (WOMAC), and WOMAC pain scores were assessed. Seventy‐nine subjects were enrolled, and 55 completed the trial. Using an intention‐to‐treat analysis, the variable‐stiffness shoes reduced the within‐day peak knee adduction moment (?5.5%, p < 0.001) in the intervention subjects, while the constant‐stiffness shoes increased the peak knee adduction moment in the control subjects (+3.1%, p = 0.015) at the 12‐month visit. WOMAC pain and total scores for the intervention group were significantly reduced from baseline to 12 months (?32%, p = 0.002 and ?35%, p = 0.007, respectively). The control group had a reduction of 27% in WOMAC pain score (p = 0.04) and no significant reduction in total WOMAC score. Reductions in WOMAC pain and total scores were similar between groups (p = 0.8 and p = 0.47, respectively). In the intervention group, reductions in adduction moment were related to improvements in pain and function (R2 = 0.11, p = 0.04). Analysis by disease severity revealed greater efficacy in adduction moment reduction in the less severe intervention group. While the long‐term effects of the intervention shoes on pain and function did not differ from control, the data suggest wearing the intervention shoe reduces the within‐day adduction moment after long‐term wear, and thus should reduce loading on the affected medial compartment of the knee. © 2011 Orthopaedic Research Society. © 2011 Orthopaedic Research Society Published by Wiley Periodicals, Inc. J Orthop Res 30:514–521, 2012 相似文献
12.
Benjamin J. Fregly Darryl D. D'Lima Clifford W. Colwell Jr. 《Journal of orthopaedic research》2009,27(8):1016-1021
Gait modification offers a noninvasive option for offloading the medial compartment of the knee in patients with knee osteoarthritis. While gait modifications have been proposed based on their ability to reduce the external knee adduction moment, no gait pattern has been proven to reduce medial compartment contact force directly. This study used in vivo contact force data collected from a single subject with a force‐measuring knee replacement to evaluate the effectiveness of two gait patterns at achieving this goal. The first was a “medial thrust” gait pattern that involved medializing the knee during stance phase, while the second was a “walking pole” gait pattern that involved using bilateral walking poles commonly used for hiking. Compared to the subject's normal gait pattern, medial thrust gait produced a 16% reduction and walking pole gait a 27% reduction in medial contact force over stance phase, both of which were statistically significant based on a two‐tailed Mann–Whitney U‐test. While medial thrust gait produced little change in lateral and total contact force over the stance phase, walking pole gait produced significant 11% and 21% reductions, respectively. Medial thrust gait may allow patients with knee osteoarthritis to reduce medial contact force using a normal‐looking walking motion requiring no external equipment, while walking pole gait may allow patients with knee osteoarthritis or a knee replacement to reduce medial, lateral, and total contact force in situations where the use of walking poles is possible. © 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 27: 1016–1021, 2009 相似文献
13.
Jennifer C. Erhart Annegret Mündermann Barbara Elspas Nicholas J. Giori Thomas P. Andriacchi 《Journal of orthopaedic research》2010,28(7):873-879
This study tested the effects of variable‐stiffness shoes on knee adduction moment, pain, and function in subjects with symptoms of medial compartment knee osteoarthritis over 6 months. Patients were randomly and blindly assigned to a variable‐stiffness intervention or constant‐stiffness control shoe. The Western Ontario and McMaster Universities (WOMAC) score served as the primary outcome measure. Joint loading, the secondary outcome measure, was assessed using the external knee adduction moment. Peak external knee adduction moment, total WOMAC, and WOMAC pain scores were assessed at baseline and after 6 months. The total WOMAC and WOMAC pain scores for the intervention group were reduced from baseline to 6 months (p = 0.017 and p = 0.002, respectively), with no significant reductions for the control group. There was no difference between groups in magnitude of the reduction in total WOMAC (p = 0.50) or WOMAC pain scores (p = 0.31). The proportion of patients achieving a clinically important improvement in pain was greater in the intervention group than in the control group (p = 0.012). The variable‐stiffness shoes reduced the peak knee adduction moment (?6.6% vs. control, p < 0.001) in the 34 intervention subjects at 6 months. The adduction moment reduction significantly improved (p = 0.03) from the baseline reduction. The constant‐stiffness control shoe increased the peak knee adduction moment (+6.3% vs. personal, p = 0.004) in the 26 control subjects at 6 months. The results of this study showed that wearing the variable‐stiffness shoe lowered the adduction moment, reduced pain, and improved functionality after 6 months of wear. The lower adduction moment associated with wearing this shoe may slow the rate of progression of osteoarthritis after long‐term use. © 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 28:873–879, 2010 相似文献
14.
Benjamin J. Fregly Scott A. Banks Darryl D. D'Lima Clifford W. Colwell Jr. 《Journal of orthopaedic research》2008,26(9):1173-1179
The ability to measure in vivo knee kinematics accurately makes it tempting to calculate in vivo contact forces, pressures, and areas directly from kinematic data. However, the sensitivity of contact calculations to kinematic measurement errors has not been adequately investigated. To address this issue, we developed a series of sensitivity analyses derived from a validated in vivo computational simulation of gait. The simulation used an elastic foundation contact model to reproduce in vivo contact force, center of pressure, and fluoroscopic motion data collected from an instrumented knee replacement. Treating each degree of freedom (DOF) in the simulation as motion controlled, we first quantified how errors in measured relative pose of the implant components affected contact calculations. Pose variations of ±0.1 mm or degree over the entire gait cycle changed maximum contact force, pressure, and area by 204, 100, and 117%, respectively. Larger variations of ±0.5 mm or degree changed these same quantities by 1157, 108, and 578%, respectively. In both cases, the largest sensitivities were to errors in superior‐inferior translation and varus‐valgus rotation, with loss of contact occurring on one or both sides. We then quantified how switching the sensitive DOFs from motion to load control affected the sensitivity results. Pose variations of ±0.5 mm or degree in the remaining DOFs changed maximum contact quantities by at most 3%. These results suggest that accuracy on the order of microns and milliradians is needed to estimate contact forces, pressures, and areas directly from in vivo kinematic measurements, and that use of load rather than motion control for the sensitive DOFs may improve the accuracy of in vivo contact calculations. © 2008 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 26:1173–1179, 2008 相似文献
15.
16.
Jonathan P. Walter Nuray Korkmaz Benjamin J. Fregly Marcus G. Pandy 《Journal of orthopaedic research》2015,33(7):1054-1060
Inverse dynamics analysis is commonly used to estimate the net loads at a joint during human motion. Most lower‐limb models of movement represent the knee as a simple hinge joint when calculating muscle forces. This approach is limited because it neglects the contributions from tibiofemoral joint contact forces and may therefore lead to errors in estimated muscle forces. The aim of this study was to quantify the contributions of tibiofemoral joint contact loads to the net knee loads calculated from inverse dynamics for multiple subjects and multiple gait patterns. Tibiofemoral joint contact loads were measured in four subjects with instrumented implants as each subject walked at their preferred speed (normal gait) and performed prescribed gait modifications designed to treat medial knee osteoarthritis. Tibiofemoral contact loads contributed substantially to the net knee extension and knee adduction moments in normal gait with mean values of 16% and 54%, respectively. These findings suggest that knee‐contact kinematics and loads should be included in lower‐limb models of movement for more accurate determination of muscle forces. The results of this study may be used to guide the development of more realistic lower‐limb models that account for the effects of tibiofemoral joint contact at the knee. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:1054–1060, 2015. 相似文献
17.
Using a pressure measuring system, we quantitatively evaluated gait pattern in patients with osteoarthrosis (OA) of the knee
before and after total knee arthroplasty (TKA). In the OA group, the stance time was longer, and the average vertical component
of the floor reaction force (AVF) was lower than the values in normal age-matched subjects. These gait parameters correlated
with the clinical score. These results suggest that changes in the gait parameters reflect gait patterns that reduce load
on the knee. The center of pressure (COP) under the foot was correlated with the axial alignment of the lower limb in the
mid-stance phase. In the TKA group, the clinical scores and gait parameters were improved 12 months after surgery compared
with the preoperative values. The COP in the mid-stance phase moved inward after the TKA. However, in patients examined more
than 2 years after a TKA, stance time and AVF did not reach normal levels, despite the patients' good clinical scores. These
findings indicate that the gait pattern before surgery continues although pain on walking is reduced early after a TKA. Gait
evaluation with a simple pressure measuring system revealed the changes in gait that are difficult to define by subjective
clinical assessment.
Received for publication on April 13, 1998; accepted on Oct. 26, 1998 相似文献
18.
Coughlin KM Incavo SJ Doohen RR Gamada K Banks S Beynnon BD 《The Journal of arthroplasty》2007,22(2):160-165
Deep flexion activities including kneeling are desired by patients after total knee arthroplasty. This in vivo radiographic study sought to reveal the effect of tibial insert design on tibiofemoral kinematics during kneeling. One group of patients received standard posterior stabilized tibial inserts, whereas the other group received posterior stabilized tibial inserts (Flex inserts) that were designed to allow more flexion. The patients with the Flex inserts achieved greater range of motion without different tibiofemoral contact behavior. 相似文献
19.
Xavier Robert-Lachaine Yoann Dessery Étienne L. Belzile Sylvie Turmel Philippe Corbeil 《Journal of orthopaedic research》2020,38(10):2262-2271
Immediate biomechanical and functional effects of knee braces are often reported, however, the duration and type of knee brace treatment for knee osteoarthritis (KOA) remain unclear. The objective was to evaluate usage, comfort, pain, and knee adduction moment (KAM) of three knee braces each worn 3 months by patients. Twenty-four patients with KOA were assigned in a randomized crossover trial a valgus three-point bending system brace (V3P-brace), an unloader brace with valgus and external rotation functions (VER-brace) and a stabilizing brace used after ligament injuries (ACL-brace). Functional questionnaires and gait assessment were carried out before and after each brace wear period of 3 months. A Friedman test was applied between brace wear diary recordings. Repeated measures analyses of variance contrasted the factors brace type (ACL, V3P, and VER), time (pre and post) and wear (without and with) on comfort, pain, function, and KAM. Brace usage was similar, but the V3P-brace was slightly less worn. Discomfort was significantly lowered with the VER-brace. All knee braces relieved pain and symptoms from 10% to 40%. KAM angular impulse was reduced with the three braces, but the VER-brace obtained the lowest relative reduction of 9%. The interaction between time and wear indicated that part of the KAM reduction with brace wear was maintained post treatment. All three knee braces have great benefits for pain and function among the medial KOA population. The VER-brace offers additional advantages on daily use, comfort and KAM, which could improve compliance to brace treatment. 相似文献
20.
High gait‐induced knee frontal plane moment is linked with the development of knee osteoarthritis. Gait patterns across the normal population exhibit large inter‐individual variabilities especially at the knee sagittal plane moment profile during loading response and terminal stance phase. However, the effects of different gait patterns on this moment remain unknown. Therefore, we examined whether different gait patterns are associated with atypically high knee frontal plane moments. Profiles of knee joint moments divided a sample of 24 subjects into three subgroups (11, 7, 6) through cluster analysis. Kinetics, kinematics, and spatio‐temporal parameters were compared among clusters. Subjects who showed a typical sagittal plane moment pattern (n = 11) had 43% lower first peak of knee frontal plane moment compared to the cluster, which showed the dominance of the knee extensor moment during stance phase (n = 7, p < 0.01). In addition, a typical gait pattern cluster had 44% lower second peak knee frontal plane moment than the cluster, which showed the dominance of the knee flexor moment during the terminal stance phase (n = 6, p < 0.05). These findings indicate that different knee strategies driving gait considerably impact knee loading, suggesting that knee extensor and flexor dominant gait patterns demonstrate atypically high knee frontal plane moments. People in these subgroups may, therefore, be at higher risk of developing knee osteoarthritis. © 2013 Orthopaedic Research Society Published by Wiley Periodicals, Inc. J Orthop Res 31:1013–1019, 2013 相似文献