首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
OBJECTIVE: Our objective was to evaluate use of gadolinium-enhanced three-dimensional (3D) MR angiography in the assessment of suspected arterial inflow stenosis after kidney transplantation. SUBJECTS AND METHODS: Twenty-eight consecutive patients receiving kidney transplants (26 single-kidney transplants and two en block transplants) with suspected arterial inflow stenosis were examined with two MR angiography sequences: gadolinium-enhanced 3D fast spoiled gradient-recalled (SPGR) imaging and 3D phase-contrast imaging. Twenty-four of these patients then were examined using the gold standards: either digital subtraction angiography (DSA) (n = 23) or surgery (n = 1). MR angiography and DSA studies were independently and prospectively analyzed for the presence of arterial stenoses (mild [<50%], severe [50-90%], or critical [>90%]) in the iliac, anastomotic, and renal artery segments. Two independent observers retrospectively evaluated the MR angiography sequences for ability to detect or exclude significant (> or = 50%) arterial stenoses. RESULTS: In 22 single-kidney transplants, DSA showed eight significant stenoses in 66 arterial segments. MR angiograms adequately showed 66 of 66 segments (prospective observers) and 64 of 66 segments (each retrospective observer), which were subsequently evaluated. The sensitivity and specificity of MR angiography in revealing significant stenoses were 100% and 98% (prospective analysis), 88% and 98% (retrospective observer 1), and 86% and 100% (retrospective observer 2). Concordance between observers showed kappa values exceeding .85 for all comparisons except the analysis of phase-contrast series (kappa = .62). In one en block transplant, DSA showed that stenosis was greater than 90%, although it had been graded at less than 50% with MR angiography. CONCLUSION: Gadolinium-enhanced 3D MR angiography accurately evaluated arterial inflow in single-kidney transplants.  相似文献   

2.
PURPOSE: To evaluate whether and to what extent greater number of projection images obtained at three-dimensional (3D) time-of-flight (TOF) magnetic resonance (MR) angiography versus conventional digital subtraction angiography (DSA) causes overestimation of internal carotid arterial (ICA) stenosis. MATERIALS AND METHODS: DSA (two or three projections), rotational angiography (16 or 32 projections), and 3D TOF MR angiography (12 projections) were performed in 47 stenotic ICAs of 38 symptomatic patients. Two observers independently measured maximum stenosis, and the mean differences among MR angiography, DSA, and rotational angiography were compared. RESULTS: Three rotational and five MR angiograms were nondiagnostic. Seven MR angiograms of ICA stenoses showed a signal void and were excluded from analysis. On the remaining 32 angiograms, mean differences in maximum stenosis for observers 1 and 2, respectively, were 7% (95% CI: 3%, 12%) and 8% (95% CI: 3%, 13%) at MR angiography versus DSA and 2% (95% CI: -2%, 7%) and -1% (95% CI: -5%, 3%) at MR angiography versus rotational angiography. ICA stenosis was graded significantly higher at MR angiography versus DSA, whereas, it was not overestimated at MR angiography versus rotational angiography. The difference in maximum stenosis at MR angiography versus DSA was significantly different from that of MR angiography versus rotational angiography. CONCLUSION: Apparent overestimation of ICA stenosis at 3D TOF MR angiography versus conventional DSA may be partly explained by the greater number of projection images available at 3D TOF MR angiography.  相似文献   

3.
PURPOSE: To prospectively evaluate accuracy of gadolinium-enhanced three-dimensional (3D) magnetic resonance (MR) angiography with gadodiamide and gadopentetate dimeglumine (0.1 mmol/kg), with intraarterial DSA as reference standard, for imaging abdominal and iliac arterial stenoses. MATERIALS AND METHODS: The study was approved by all institutional review boards; informed consent was obtained from each subject before procedures. Two hundred forty-seven subjects were included; 240 received either contrast agent and were available for safety analysis; 222 were available for accuracy analysis. Enhanced 3D MR angiography and DSA were performed; image data were evaluated in a double-blinded randomized study. Stenoses were classified as not relevant (<50% stenosis) or relevant (> or =50%). For detection of main stenosis, accuracy with enhanced 3D MR angiography compared with that with DSA was determined. RESULTS: The difference in accuracy for imaging with gadodiamide and gadopentetate was 3.6%. Noninferiority was inferred because the lower bound of the exact two-sided 95% confidence interval was -10.1 and was above the noninferiority margin (-15%). Accuracy for detection of the main stenosis was low, 56.4% for gadodiamide and 52.8% for gadopentetate group. Subgroup analysis with exclusion of inferior mesenteric artery and internal iliac arteries and the most false-positive stenosis classifications yielded better results: 76.6% and 71.6%, respectively. Sensitivity, specificity, and negative and positive predictive values did not differ substantially between study groups. In the main analysis, values were 44%, 96%, 35%, and 97% for gadodiamide and 44%, 83%, 30%, and 90% for gadopentetate, respectively. In the subgroup analysis, values were 66%, 95%, 61%, and 96% for gadodiamide and 63%, 86%, 58%, and 88% for gadopentetate, respectively. CONCLUSION: Noninferiority of gadodiamide versus gadopentetate was verified based on the primary end point, which was accuracy for detection of the main stenosis with enhanced 3D MR angiography compared with DSA.  相似文献   

4.
PURPOSE: To prospectively use 3.0-T breath-hold high-spatial-resolution contrast material-enhanced magnetic resonance (MR) angiography with highly accelerated parallel acquisition to image the supraaortic arteries of patients suspected of having arterial occlusive disease. MATERIALS AND METHODS: Institutional review board approval and written informed consent were obtained for this HIPAA-compliant study. Eighty patients (44 men, 36 women; age range, 44-90 years) underwent contrast-enhanced MR angiography of the head and neck at 3.0 T with an eight-channel neurovascular array coil. By applying a generalized autocalibrating partially parallel acquisition algorithm with an acceleration factor of four, high-spatial-resolution (0.7 x 0.7 x 0.9 mm = 0.44-mm(3) voxels) three-dimensional contrast-enhanced MR angiography was performed during a 20-second breath hold. Two neuroradiologists evaluated vascular image quality and arterial stenoses. Interobserver variability was tested with the kappa coefficient. Quantitation of stenosis at MR angiography was compared with that at digital subtraction angiography (DSA) (n = 13) and computed tomographic (CT) angiography (n = 12) with Spearman rank correlation coefficient (R(s)). RESULTS: Arterial stenoses were detected with contrast-enhanced MR angiography in 208 (reader 1) and 218 (reader 2) segments, with excellent interobserver agreement (kappa = 0.80). There was a significant correlation between contrast-enhanced MR angiography and CT angiography (R(s) = 0.95, reader 1; R(s) = 0.87, reader 2) and between contrast-enhanced MR angiography and DSA (R(s) = 0.94, reader 1; R(s) = 0.92, reader 2) for the degree of stenosis. Sensitivity and specificity of contrast-enhanced MR angiography for detection of arterial stenoses greater than 50% were 94% and 98% for reader 1 and 100% and 98% for reader 2, with DSA as the standard of reference. Vascular image quality was sufficient for diagnosis or excellent for 97% of arterial segments evaluated. CONCLUSION: By using highly accelerated parallel acquisition, the described 3.0-T contrast-enhanced MR angiographic protocol enabled visualization and characterization of the majority of supraaortic arteries, with diagnostic or excellent image quality (97% of arterial segments) and diagnostic values comparable with those obtained by using CT angiography and DSA for detection of arterial stenoses.  相似文献   

5.
OBJECTIVE: Catheter-based intraarterial injections of gadolinium are useful during MR imaging-guided endovascular procedures to generate rapid vascular road maps. Using an animal model of renal artery stenosis, we tested the hypothesis that intraarterial gadolinium-enhanced MR angiography is as accurate as IV gadolinium-enhanced MR angiography and digital subtraction angiography (DSA). We also tested the hypothesis that intraarterial MR angiography uses less gadolinium than IV MR angiography. MATERIALS AND METHODS: We induced bilateral renal artery stenosis in five pigs. All pigs underwent comparative imaging with DSA, IV MR angiography, and aortic catheter-directed intraarterial MR angiography. For IV and intraarterial MR angiography, we used the same three-dimensional acquisition. We assessed differences in quantitative stenosis measurements among DSA, IV MR angiography, and intraarterial MR angiography using the Wilcoxon's signed rank test. RESULTS: Mean stenosis measurements (+/-SD) were as follows: DSA, 58% +/- 12%; IV MR angiography, 63% +/- 9.3%; and intraarterial MR angiography, 64% +/- 11%. There were no statistically significant differences in accuracy between DSA and IV MR angiography (p = 0.06), DSA and intraarterial MR angiography (p = 0.16), or IV and intraarterial MR angiography (p = 0.70). Intraarterial MR angiography used a mean gadolinium dose of 5.6 mL, compared with 9 mL for IV MR angiography. CONCLUSION: In swine, IV and intraarterial MR angiography have a similar accuracy for detecting renal artery stenosis. Intraarterial MR angiography uses smaller doses of injected gadolinium.  相似文献   

6.
PURPOSE: To compare three-dimensional (3D) time-of-flight (TOF) MR angiography, contrast-enhanced MR angiography, digital subtraction angiography (DSA), and rotational angiography for depiction of stenosis. MATERIALS AND METHODS: The study had Ethics Committee approval, and each patient gave written informed consent. Forty-nine patients (18 women, mean age, 67.2 years +/- 9.1 [+/- standard deviation], and 31 men, mean age, 63.1 years +/- 8.0) with symptomatic stenosis of internal carotid artery (ICA) diagnosed at duplex ultrasonography underwent transverse 3D TOF MR angiography with sliding interleaved kY acquisition and coronal contrast-enhanced MR angiography, followed by DSA and rotational angiography within 48 hours. MR angiography was performed at 1.5-T with a cervical coil. Contrast-enhanced MR angiograms were obtained after a bolus injection of 20 mL of gadobenate dimeglumine. Maximum ICA stenosis on maximum intensity projection and source images was quantified according to NASCET criteria. Correlations for 3D TOF MR angiography, contrast-enhanced MR angiography, DSA, and rotational angiography were determined by means of cross tabulation, and accuracy for detection and grading of stenoses were calculated. Data were evaluated with analysis of variance, Wilcoxon signed rank test, and McNemar test, all at significance of P < .05. RESULTS: Ninety-eight ICAs were evaluated at contrast-enhanced MR angiography, DSA, and rotational angiography, and 97 were evaluated at 3D TOF MR angiography. Correlations for contrast-enhanced MR angiography, 3D TOF MR angiography, and DSA relative to rotational angiography were r2 = 0.9332, r2 = 0.9048, and r2 = 0.9255, respectively. Lower correlation (r2 = 0.8593) was noted for contrast-enhanced MR angiography and DSA. Respective sensitivity and specificity for detection of hemodynamically relevant stenosis relative to rotational angiography were 100% and 90% for contrast-enhanced MR angiography, 95.5% and 87.2% for 3D TOF MR angiography, and 88.6% and 100% for DSA. Four of 31 severe stenoses were underestimated at DSA, and three were underestimated at contrast-enhanced MR angiography. Three severe stenoses were underestimated at 3D TOF MR angiography, and one was misclassified as occluded. Of 13 moderate (50%-69%) stenoses, one was overestimated at contrast-enhanced MR angiography, two were underestimated and three overestimated at 3D TOF MR angiography, and two were underestimated at DSA. CONCLUSION: DSA results in an underestimation of ICA stenosis compared with rotational angiography. Contrast-enhanced MR angiography correlates best with rotational angiography.  相似文献   

7.
BACKGROUND AND PURPOSE: Since 1996, several preliminary studies have shown the usefulness of contrast material-enhanced MR angiography for imaging supraaortic vessels. The aim of this study was to compare the accuracy of contrast-enhanced 3D MR angiography with that of digital subtraction angiography (DSA) in the evaluation of carotid artery stenosis. METHODS: A blinded comparison of first-pass contrast-enhanced MR angiography with conventional DSA was performed in 120 patients (240 arteries). MR angiography was performed with a 1.5-T magnet with gradient overdrive equipment, by using a coronal radiofrequency-spoiled 3D fast low-angle-shot sequence after the intravenous injection of gadodiamide. The guidelines of the North American Symptomatic Carotid Endarterectomy Trial for measuring stenosis of the internal carotid artery were applied on maximum intensity projection (MIP) images and conventional catheter angiograms. RESULTS: Grading of stenoses on MR angiograms agreed with grading of stenoses on DSA images in 89% of arteries. In the severe stenosis group (70-99%), agreement was 93%. All internal carotid occlusions (n = 28) and seven of nine pseudo-occlusions were accurately detected with contrast-enhanced MR angiography. The correlation between MR angiography and DSA for determination of minimal, moderate, and severe stenoses and occlusion was statistically significant (r = 0.91, P<.001). CONCLUSIONS: This investigation with a large number of patients confirms that contrast-enhanced MR angiography could become a diagnostic alternative to DSA in the treatment of patients with carotid artery disease.  相似文献   

8.
PURPOSE: To compare color Doppler ultrasonography (US) with fast, breath-hold, three-dimensional, gadolinium-enhanced magnetic resonance (MR) angiography in detecting renal arterial stenosis. MATERIALS AND METHODS: Forty-five patients with clinical suspicion of renovascular disease were prospectively examined with intra- and extrarenal color Doppler US and breath-hold, gadolinium-enhanced MR angiography. Digital subtraction arteriography (DSA) was the standard of reference in all patients for the number of renal arteries and degree of stenosis. RESULTS: DSA depicted 103 arteries and 52 stenoses. Color Doppler US was nondiagnostic in two examinations. Significantly more of 13 accessory renal arteries were detected with MR angiography (n = 12) than with color Doppler US (n = 3; P <.05). For assessing all stenoses, the sensitivity and accuracy were 94% and 91%, respectively, for MR angiography and 71% and 76%, respectively, for US (P <.05). The sensitivity was higher for MR angiography (100%) than for US (79%; P <.05) in diagnosing stenoses with at least 50% narrowing. The specificity, accuracy, and negative predictive value in diagnosing stenoses of at least 50% narrowing were 93%, 95%, and 100% for MR angiography and 93%, 89%, and 90% for US. CONCLUSION: Breath-hold, gadolinium-enhanced MR angiography is superior to color Doppler US in accessory renal artery detection. Although the specificity of MR angiography is similar to that of color Doppler US, MR angiography has a better sensitivity and negative predictive value in depicting renal arterial stenoses.  相似文献   

9.
BACKGROUND AND PURPOSE: Although digital subtraction angiography (DSA) is the reference standard for assessing carotid arteries, it is uncomfortable for patients and has a small risk of disabling stroke and death. These problems have fueled the use of spiral CT angiography and MR angiography. We prospectively compared elliptic centric contrast-enhanced MR angiography and spiral CT angiography with conventional DSA for detecting carotid artery stenosis. METHODS: Eighty carotid arteries (in 40 symptomatic patients) were assessed. Elliptic centric MR and spiral CT angiographic data were reconstructed with maximum intensity projection and multiplanar reconstruction techniques. All patients had been referred for DSA evaluation on the basis of findings at Doppler sonography, which served as a screening method (degree of stenosis > or = 70% or inconclusive results). Degree of carotid stenosis estimated by using the three modalities was compared. RESULTS: Significant correlation with DSA was found for stenosis degree for both elliptic centric MR and spiral CT angiography; however, the correlation coefficient was higher for MR than for CT angiography (r = 0.98 vs r = 0.86). Underestimation of stenoses of 70-99% occurred in one case with elliptic centric MR angiography (a 70% stenosis was underestimated as 65%) and in nine cases with spiral CT angiography, in comparison to DSA findings. Overestimation occurred in two cases with MR angiography (stenoses of 65-67% were overestimated as 70-75%). With CT, overestimation occurred in seven cases; a stenosis of 60% in one case was overestimated as 70%. Both techniques confirmed the three cases of carotid occlusion. With elliptic centric MR angiography, carotid stenoses of 70% or greater were detected with high sensitivity, 97.1%; specificity, 95.2%; likelihood ratio (LR) for a positive test result, 20.4; and ratio of LR(+) to LR(-), -0.3. With spiral CT angiography, sensitivity, specificity, LR(+), and LR(+):LR(-) were 74.3%, 97.6%, 31.2, and 0.3, respectively. CONCLUSION: Elliptic centric contrast-enhanced MR angiography is more accurate than spiral CT angiography to adequately evaluate carotid stenosis. Furthermore, elliptic centric contrast-enhanced MR angiography appears to be adequate to replace conventional DSA in most patients examined.  相似文献   

10.
PURPOSE: To prospectively compare the image quality, sensitivity, and specificity of three-dimensional gadolinium-enhanced magnetic resonance (MR) angiography accelerated by parallel acquisition (ie, fast MR angiography) with MR angiography not accelerated by parallel acquisition (ie, conventional MR angiography) for assessment of aortoiliac and renal arteries, with digital subtraction angiography (DSA) as the reference standard. MATERIALS AND METHODS: The study was approved by the institutional review board; informed consent was obtained from all patients. Forty consecutive patients (33 men, seven women; mean age, 63 years) suspected of having aortoiliac and renal arterial stenoses and thus examined with DSA underwent both fast (mean imaging time, 17 seconds) and conventional (mean imaging time, 29 seconds) MR angiography. The arterial tree was divided into segments for image analysis. Two readers independently evaluated all MR angiograms for image quality, presence of arterial stenosis, and renal arterial variants. Image quality, sensitivity, and specificity were analyzed on per-patient and per-segment bases for multiple comparisons (with Bonferroni correction) and for dependencies between segments (with patient as the primary sample unit). Interobserver agreement was evaluated by using kappa statistics. RESULTS: Overall, the image quality with fast MR angiography was significantly better (P=.001) than that with conventional MR angiography. At per-segment analysis, the image quality of fast MR angiograms of the distal renal artery tended to be better than that of conventional MR angiograms of these vessels. Differences in sensitivity for the detection of arterial stenosis between the two MR angiography techniques were not significant for either reader. Interobserver agreement in the detection of variant renal artery anatomy was excellent with both conventional and fast MR angiography (kappa=1.00). CONCLUSION: Fast MR angiography and conventional MR angiography do not differ significantly in terms of arterial stenosis grading or renal arterial variant detection.  相似文献   

11.
BACKGROUND AND PURPOSE: Contrast-enhanced MR angiography and extracranial color-coded duplex sonography are noninvasive, preoperative imaging modalities for evaluation of carotid artery stenosis. Innovative techniques and improvements in image quality require frequent reassessment of accuracy, reliability, and diagnostic value compared with those of digital subtraction angiography (DSA). We evaluated contrast-enhanced MR angiography and duplex sonography compared with DSA for detection of high-grade carotid artery stenoses. METHODS: Four readers, blinded to clinical symptoms and the outcome of other studies, independently evaluated stenoses on contrast-enhanced MR angiograms in 71 vessels of 39 symptomatic patients. Duplex sonography was also performed in all vessels. The severity of stenosis was defined according to North American Symptomatic Carotid Endarterectomy Trial criteria (0-29%, 30-69%, 70-99%, 100%). Results of both modalities were compared with the corresponding DSA findings. RESULTS: Contrast-enhanced MR angiography had a sensitivity and specificity of 94.9% and 79.1%, respectively, for the identification of carotid artery stenoses of 70% or greater. Sensitivity and specificity of duplex sonography were 92.9% and 81.9%, respectively. Combining data from both tests revealed a sensitivity and specificity of 100% and 81.4%, respectively, for concordant results (80% of vessels). CONCLUSION: Concordant results of contrast-enhanced MR angiography and duplex sonography increase the diagnostic sensitivity to 100%. The reliability of MR angiography is comparable to that of DSA. The combination of contrast-enhanced MR angiography and duplex sonography might be preferable over DSA for preoperative evaluation in most patients, thus reducing the risk of perioperative morbidity and improving the overall outcome.  相似文献   

12.
PURPOSE: Results with different doses of gadobenate dimeglumine and gadopentetate dimeglumine were compared at magnetic resonance (MR) angiography of the renal arteries. The signal-to-noise ratio (SNR) was evaluated as a quantitative measure of image quality. MATERIALS AND METHODS: Sixty consecutive patients (age range, 24-81 years; mean age, 65 years) underwent intraarterial digital subtraction angiography (DSA) and contrast material-enhanced time-resolved MR angiography. DSA was the standard of reference. Fifteen patients received gadopentetate dimeglumine at doses of 0.2 or 0.1 mmol per kilogram of body weight. Fifteen patients received gadobenate dimeglumine at doses of 0.05 or 0.1 mmol/kg. The SNR was calculated in the aorta and both main renal arteries. The number and degree of stenoses of the renal arteries and accessory vessels were evaluated by four observers. RESULTS: SNRs with gadobenate dimeglumine at a dose of 0.1 mmol/kg were significantly superior to those with gadopentetate dimeglumine at a dose of 0.1 mmol/kg. Differences were not statistically significant between the SNRs in the other groups. Eleven (85%) of 13 hemodynamically significant renal artery stenoses were detected correctly with MR angiography as were 22 (85%) of 26 accessory renal arteries. CONCLUSION: SNRs with gadobenate dimeglumine were higher than those with gadopentetate dimeglumine, but in most cases the differences in SNRs were not statistically significant.  相似文献   

13.
PURPOSE: To prospectively assess three-dimensional contrast material-enhanced magnetic resonance (MR) angiography for stenosis depiction in malfunctioning hemodialysis arteriovenous fistulas (AVFs) and grafts (AVGs), as compared with digital subtraction angiography (DSA). MATERIALS AND METHODS: Ethical review board approval and written informed consent were obtained. MR angiography and DSA were performed in 51 dysfunctional hemodialysis fistulas and grafts in 48 consecutive patients. Vascular tree of accesses was divided into between three and eight segments depending on access type (AVF or AVG) and length of venous outflow. Images obtained with MR and DSA were interpreted by two MR radiologists and two interventional radiologists, respectively, who were blinded to information from each other and other studies. DSA was reference standard for stenosis detection. Sensitivity, specificity, and predictive values with 95% confidence intervals (CIs) of contrast-enhanced MR in detection of vascular segments containing hemodynamically significant (> or =50%) stenosis were calculated. Linear-weighted kappa statistic was calculated for contrast-enhanced MR and DSA to determine interobserver agreement regarding stenosis detection. RESULTS: A total of 282 vascular segments were evaluated. Contrast-enhanced MR depicted three false-positive stenoses and all but two of 70 significant stenoses depicted with DSA. Sensitivity, specificity, and positive and negative predictive values of MR in detection of vessel segments with significant stenoses were 97% (95% CI: 90%, 99%), 99% (95% CI: 96%, 100%), 96% (95% CI: 88%, 99%), and 99% (95% CI: 97%, 100%), respectively. MR demonstrated significant stenosis in four of five nondiagnostic DSA segments, whereas DSA showed no significant stenosis in four nondiagnostic MR segments. Linear-weighted kappa statistic for interobserver agreement regarding stenosis detection was 0.92 (95% CI: 0.89, 0.95) for MR and 0.95 (95% CI: 0.92, 0.97) for DSA. CONCLUSION: MR angiography depicts stenoses in dysfunctional hemodialysis accesses but has limited clinical value as result of current inability to perform MR-guided access interventions after stenosis detection. MR of dysfunctional access should be considered only if nondiagnostic vascular segment is present at DSA.  相似文献   

14.
PURPOSE: To determine whether computed tomographic (CT) angiography with the volume-rendering technique (VRT) can be used to accurately quantify carotid arterial stenosis and to identify occlusions. MATERIALS AND METHODS: Spiral CT was performed in 23 patients who were referred for carotid stenosis evaluation. VRT images and shaded-surface display (SSD) images of 46 carotid arterial bifurcations were compared with findings from digital subtraction angiography (DSA). RESULTS: Agreement on stenosis category between VRT CT angiography and DSA was found in 39 (85%) of the 46 carotid arteries studied. VRT CT angiography was 92% (49 of 53) sensitive and 96% (82 of 85) specific for the detection of grade 2-3 stenoses (> or = 70% stenosis). Agreement on stenosis category between SSD CT angiography and DSA was found in 38 (83%) of the 46 carotid arteries studied. SSD CT angiography was 91% (48 of 53) sensitive and 93% (79 of 85) specific for the detection of grade 2-3 stenoses. Calcified stenoses were correctly graded at VRT CT angiography in 10 of the 10 cases with heavy mural calcified plaques, while eight of the 10 stenoses were accurately quantified at SSD CT angiography. CONCLUSION: These results indicate that VRT CT angiography is as accurate as SSD CT angiography in the evaluation of carotid arterial bifurcations.  相似文献   

15.
PURPOSE: To compare contrast material-enhanced three-dimensional (3D) magnetic resonance (MR) angiography and multi-detector row computed tomographic (CT) angiography in the same patients for assessment of the aortoiliac and renal arteries, with digital subtraction angiography (DSA) as the standard of reference. MATERIALS AND METHODS: DSA, 3D MR angiography, and multi-detector row CT angiography were performed in 46 consecutive patients. A total of 769 arterial segments were analyzed for arterial stenosis by using a four-point grading system. Aneurysmal changes were noted. The time required for performing 3D reconstructions and image analysis of both MR and CT data sets was measured. Patient acceptance for each modality was assessed with a visual analogue scale. Statistical analysis of data was performed. RESULTS: Sensitivity of MR angiography for detection of hemodynamically significant arterial stenosis was 92% for reader 1 and 93% for reader 2, and specificity was 100% and 99%, respectively. Sensitivity of CT angiography was 91% for reader 1 and 92% for reader 2, and specificity was 99% and 99%, respectively. Differences between the two modalities were not significant. Interobserver and intermodality agreement was excellent (kappa = 0.88-0.90). The time for performance of 3D reconstruction and image analysis of CT data sets was significantly longer than that for MR data sets (P <.001). Patient acceptance was best for CT angiography (P =.016). CONCLUSION: There is no statistically significant difference between 3D MR angiography and multi-detector row CT angiography in the detection of hemodynamically significant arterial stenosis of the aortoiliac and renal arteries.  相似文献   

16.
OBJECTIVE: The aim of our study was to evaluate a three-dimensional gadolinium-enhanced breath-hold MR angiography sequence using standard MR gradients in detecting renal artery stenosis. SUBJECTS AND METHODS: Forty-two patients referred for angiography for suspected renal artery stenosis underwent both conventional digital subtraction angiography (DSA) and MR angiography. MR angiography was performed on a 1.5-T scanner with standard gradients. A fast multiplanar spoiled gradient-echo sequence was used with the following parameters: TR/TE, 10.3/1.9; flip angle, 45 degrees; field of view, 36 x 32 cm; matrix size, 256 x 128; one excitation; volume thickness, 70 mm; and partitions, 28. Gadolinium was administered IV as a dynamic bolus of 30-40 ml. Conventional and MR angiographic images were interpreted by two radiologists in consensus. RESULTS: DSA revealed 87 renal arteries, of which 79 were in 35 patients with native kidneys and eight arteries were in seven patients with transplanted kidneys. Gadolinium-enhanced MR angiography showed 85 (98%) of 87 renal arteries. Seventeen patients had 20 significant (>50% stenosis) renal artery stenoses and five patients had five occluded renal arteries revealed by DSA. MR angiography revealed 85 renal arteries (98%), 20 stenoses (100%), and five occlusions (100%). Gadolinium-enhanced MR angiography led to one false-positive interpretation for renal artery stenosis and no false-negative interpretations. Thus, the sensitivity, specificity, and accuracy of MR angiography for renal artery stenosis were 100%, 98%, and 99%, respectively. CONCLUSION: The MR angiography pulse sequence we used was an effective and reliable technique for the diagnosis of renal artery stenosis. The sequence can be performed on widely available MR equipment that does not require fast gradient hardware.  相似文献   

17.
PURPOSE: To prospectively test the hypothesis that magnetic resonance (MR) imaging can detect changes in renal function at the time of renal artery stent placement in a swine model of renal artery stenosis (RAS). MATERIALS AND METHODS: In this animal care and use committee-approved study, hemodynamically significant (>50%) RAS was surgically induced in six pigs. MR imaging was employed for assessment of the anatomic and physiologic changes induced by fluoroscopically guided stent placement. With MR imaging, we assessed changes in renal blood flow (RBF), extraction fraction (EF), and single-kidney glomerular filtration rate (skGFR) during the procedure. Arterial diameter stenosis before and after stent placement was assessed with x-ray digital subtraction angiography (DSA). Mean changes in functional and anatomic parameters were compared with the Wilcoxon matched-pairs test, with an alpha level of 0.05. RESULTS: There was no significant change in mean RBF after stent deployment (P=.44). Mean EF increased from 0.19+/-0.08 before stent placement to 0.31+/-0.17 after stent placement (P=.16). Mean skGFR measurements were 25 mL/min+/-16 before stent placement and 41 mL/min+/-28 after stent placement (P<.05). According to x-ray DSA measurements, mean stenosis measurements were 60%+/-12% before stent placement and 24%+/-16% after stent placement (P<.02). CONCLUSIONS: In swine, MR imaging can detect immediate changes in renal function after radiographically guided stent placement for unilateral RAS. This functional MR technique may have applications in the setting of hybrid MR/x-ray DSA procedure suites.  相似文献   

18.
The objective of this study was to determine the clinical utility of a contrast-enhanced, centric reordered, three-dimensional (3D) MR angiography (MRA) pulse sequence in imaging the abdominal aorta and renal and peripheral lower extremity arteries. Twenty-eight MRA studies were performed on 23 patients and four volunteers at 1.5 T using a 3D contrast-enhanced, centric reordered pulse sequence. In 20 patients, the abdominal aorta and renal arteries were imaged, and in seven patients, the lower extremity arteries were imaged. In 19 patients, a total of 51 renal vessels were evaluated (33 renal arteries using .1 mmol/kg of gadopentetate dimeglumine and 18 renal arteries using .2 mmol/kg of gadoteridol). A total of 70 peripheral arterial segments were assessed using .2 mmol/kg of gadoteridol. Correlation with conventional angiography was made for the following 14 cases: renal artery stenosis (four cases), abdominal aortic stenosis (one case), arteriovenous fistula in a transplant kidney (one case), renal arteriovenous malformation (one case), common iliac artery aneurysms (one case), and peripheral lower extremity (six cases). Of the 70 peripheral arterial segments evaluated, in 35, there was correlation with x-ray angiography. The mean percent of aortic signal enhancement was significantly higher in the .2 mmol/kg dose group (370.8 ± 190.3) than in the .1 mmol/kg dose group (184.5 ± 128.9) (P = .02). However, there was no apparent difference between the two doses for visualization of the renal and accessory renal arteries. There was concordance between the contrast-enhanced 3D MRA studies and conventional angiography in all cases of renal artery and peripheral arterial stenoses and occlusions, including visualization of reconstituted peripheral arterial segments. There was no evidence of spin dephasing effects at sites of stenoses on the 3D contrast-enhanced MRA studies. Contrast-enhanced, centric reordered, 3D MRA can rapidly image the abdominal aorta and renal and accessory renal arteries, as well as peripheral lower extremity arteries, with high resolution. Accurate depiction of the vascular lumen at sites of stenosis is made because of the lack of spin dephasing effects, even with hemody-namically significant stenoses. Additional larger clinical trials are required with this promising technique.  相似文献   

19.
PURPOSE: To compare volume rendering (VR) and maximum intensity projection (MIP) as postprocessing techniques of magnetic resonance (MR) angiography for detection and quantification of renal artery stenosis. MATERIALS AND METHODS: Twenty-seven patients underwent three-dimensional contrast material-enhanced MR angiography of the renal arteries with a 1.5-T imager. For each renal artery, targeted MIP and VR images were reconstructed in oblique coronal and transverse orientations. For each modality, image generation and evaluation were performed interactively by two independent radiologists blinded to angiographic results. In comparison with digital subtraction angiography (DSA) findings, stenosis quantification and detection by using MIP and VR were evaluated with the use of 50% and 70% cutoff points by using linear regression analysis and 2 x 2 tables. Overall image quality and vascular delineation on MIP and VR images were also compared. RESULTS: All main and accessory renal arteries depicted at DSA were also demonstrated on MIP and VR images. VR performed slightly better than MIP for quantification of stenoses greater than 50% (VR: r(2) = 0.84, P <.001; MIP: r(2) = 0.38, P =.001) and significantly better for severe stenoses (VR: r(2) = 0.83, P <.001; MIP: r(2) = 0.21, P =.1). For detection of stenosis, VR yielded a substantial improvement in positive predictive value (VR: 95% and 90%; MIP: 86% and 68% for stenoses greater than 50% and 70%, respectively). Image quality obtained with VR was not significantly better than that with MIP; however, vascular delineation on VR images was significantly better. CONCLUSION: The VR technique of renal MR angiography enabled more accurate detection and quantification of renal artery stenosis than did MIP, with significantly improved vascular delineation.  相似文献   

20.
OBJECTIVE: Our study was a prospective in vivo study to evaluate whether MR angiography is suitable for assessing stent patency and grading in-stent stenoses and to examine whether the accuracy of MR angiography changes with time after stent implantation. SUBJECTS AND METHODS: In a prospective study, 34 iliac stenoses in 27 patients were treated by implantation of 35 nitinol stents. MR angiography was performed immediately after stent placement for 32 stents, and both digital subtraction angiography (DSA) and MR angiography were repeated at the 6-month follow-up for 23 stents. Three blinded observers assessed stent patency and the degree of in-stent stenoses on MR angiography and DSA (the standard of reference) images. The difference between the observers' grading of stenoses on DSA and on MR angiography was determined. Statistical analysis was performed using the Student's t test for paired samples. RESULTS: Stent patency was assessed correctly for all stents and both sets of MR angiography images. Evaluation of DSA 1 images (obtained at end of implantation procedure) revealed that 96.9% of in-stent stenoses were less than 50%. On DSA 2 images (obtained at follow-up), 95.7% of in-stent stenoses were graded as less than 50%. The difference between grading of stenoses on DSA and MR angiography images was 15.0% +/- 16.0% (minimum, 0.0%; maximum, 63.3%) for DSA 1 versus MR angiography 1 (statistically significant, p = 0.037) and 9.8% +/- 13.5% (minimum, 0.0%; maximum, 63.3%) for MR angiography 2 versus DSA 2 (not statistically significant, p = 0.355). CONCLUSION: Patency was correctly assessed for all stents on MR angiography. The quality of MR angiography regarding characterization of in-stent stenoses improved with time after stent placement. However, discrepancies of more than 60% between grading of lumen narrowing on DSA and MR angiography images occurred even at the 6-month follow-up. Thus, MR angiography is not yet a reliable technique for characterization of in-stent stenoses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号