OBJECTIVE: Evaluation of left ventricular function using electrocardiogram (ECG)-gated multidetector row CT (MDCT) by using 3 different volumetric assessment methods in comparison to assessment of the left ventricular function by invasive ventriculography. METHODS: Thirty patients with suspected or known coronary artery disease underwent MDCT coronary angiography with retrospective ECG cardiac gating. Raw data were reconstructed at the end-diastolic and end-systolic periods of the heart cycle. To calculate the volumes of the left ventricle, 3 methods were applied: The 3-dimensional data set (3D), the geometric hemisphere cylinder (HC), and the geometric biplane ellipsoid (BE) methods. End-diastolic volumes (EDV), end-systolic volumes (ESV), the stroke volumes (SV), and ejection fractions (EF) were calculated. The left ventricular volumetric data from the 3 methods were compared with measurements from left ventriculography (LVG). RESULTS: The best results were obtained using the 3D method; EDV (r = 0.73), ESV (r = 0.88), and EF (r = 0.76) correlated well with the LVG data. The EDV volumes did not differ significantly between LVG and the 3D method (P = 0.24); however, ESV, SV, and EF differed significantly. The ESV were significantly overestimated (P < 0.01), leading to an underestimation of the SV (P < 0.01) and the EF (P < 0.01). The HC method resulted in the greatest overestimation of the volumes. The EDV and the ESV were 31.8 +/- 37.6% and 136.4 +/- 92.9% higher than the EDV and ESV volumes obtained by LVG. Bland-Altman analysis showed systematic overestimation of the ESV using the HC method. CONCLUSION: MDCT with retrospective cardiac ECG gating allows the calculation of left ventricular volumes to estimate systolic function. The 3D method had the highest correlation with LVG. However, the overestimation of the ESV is significant, which led to an underestimation of the SV and the EF.  相似文献   

2.
We compared the left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) as calculated by Cedars automated quantitative gated SPECT (QGS) to those determined by first-pass radionuclide angiography (FPRNA) and contrast left ventriculography (LVG) in a group of 21 patients (mean age 61.4 +/- 9.2 y). METHODS: A total of 740 MBq 99mTc-tetrofosmin was administered rapidly into the right cubital vein at rest, and FPRNA was performed using a multicrystal gamma camera. One hour after injection, QGS was performed with a temporal resolution of 10 frames per R-R interval. LVG was performed within 2 wk. RESULTS: The EDV, ESV and LVEF calculated by QGS were highly reproducible (intraobserver, r = 0.99, r = 0.99 and r = 0.99, respectively; interobserver, r = 0.99, r = 0.99 and r = 0.99, respectively; P < 0.01) and were more consistent than those determined by FPRNA (intraobserver, r = 0.97, r = 0.95 and r = 0.93, respectively; interobserver, r = 0.86, r = 0.96 and r = 0.91, respectively; P < 0.01). There was a good correlation between EDV, ESV and LVEF by FPRNA and those by LVG (r = 0.61, r = 0.72 and r = 0.91, respectively; P < 0.01), and there was an excellent correlation between QGS and LVG (r = 0.73, r = 0.83 and r = 0.87, respectively; P < 0.01). The mean EDV by QGS (100 +/- 11.3 mL) was significantly lower than by FPRNA (132 +/- 16.8 mL) or LVG (130 +/- 8.1 mL), and the mean ESV by QGS (53.8 +/- 9.3 mL) was lower than by FPRNA (73.0 +/- 13.3 mL). Ejection fraction values were highest by LVG (57.1% +/- 3.2%), then QGS (51.8% +/- 3.0%) and FPRNA (48.9% +/- 2.4%). CONCLUSION: QGS gave more reproducible results than FPRNA. LV volumes and LVEF calculated by QGS correlated well to those by LVG.  相似文献   

3.
PURPOSE: Multi-detector row CT (MDCT) is a new noninvasive modality for coronary artery imaging. Using the same MDCT data obtained for coronary artery assessment, left ventricular (LV) volumes such as end-diastolic (ED) and end-systolic (ES) volumes (EDV and ESV, respectively) and ejection fraction (EF) can potentially be assessed when ED and ES datasets are extracted. The purpose of this study was to evaluate the feasibility of MDCT in the assessment of LV volumes. METHODS: Using a pulsating heart phantom (EDV = 143 ml, ESV = 107 ml, stroke volume = 36 ml, EF = 25%) and MDCT, EDV and ESV were measured and EF was calculated. Clinical materials consisted of 11 consecutive human subjects who underwent MDCT. MDCT data were acquired during a single breathhold, using an intravenous injection of contrast medium. Left ventriculography (LVG) was performed in all patients as a gold standard. LV-EF was calculated by measuring ESV and EDV in all patients. RESULTS: In the phantom study, LV volumes were: EDV = 137 ml, ESV = 101 ml, stroke volume = 36 ml, and EF = 26%. Close correlations were observed between MDCT values and LVG values (EDV: r = 0.95, ESV: r = 0.98, EF: r = 0.93, p < 0.001). CONCLUSION: MDCT was useful for th e assessment of LV volumes and EF in various patients with CVD.  相似文献   

4.
OBJECTIVE: The aim of this study was to evaluate the left ventricular (LV) functional parameters calculated using quantitative electrocardiography (ECG)-gated myocardial perfusion single photon emission computed tomography (QGS). In addition to LV systolic parameters, diastolic parameters were compared with those by ultrasound echocardiography (UCG) and also with plasma B-type natriuretic peptide (BNP) concentrations. METHODS: We examined 46 patients with various forms of heart disease. By the QGS data with 16 framing data acquisition using technetium (Tc)-99m methoxyisobutylisonitrile (MIBI) perfusion, we calculated the following parameters: LV end-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), peak filling rate (PFR), filling rate during the first third of the filling time (1/3FR) and first third filling fraction (1/3FF). By UCG, we measured mitral early to atrial (E/A) wave velocity ratio and pulmonary venous inflow systolic/diastolic (S/D) ratio as diastolic functional parameters. Plasma BNP concentrations were also measured. RESULTS: There was a significant correlation between LVEDV, ESV and EF measured by QGS and UCG (EDV, r = 0.71, p < 0.001; ESV, r = 0.82, p < 0.001; EF, r = 0.75, p < 0.001). The PFR, 1/3FR and 1/3FF obtained by QGS correlated positively with E/A ratio (PFR, r = 0.54, p < 0.001; 1/3FR, r = 0.61, p < 0.001; 1/3FF, r = 0.42, p < 0.01) and negatively with S/D ratio (PFR, r = -0.40, p < 0.01; 1/3FR, r = -0.38, p < 0.05; 1/3FF, r = -0.39, p < 0.01) obtained by UCG. Plasma BNP concentrations in EF < 50% patients were greater than those in EF > or = 50% patients (335.2 +/- 60.2 vs. 101.2 +/- 41.3 pg/ml, p < 0.01, both n = 17). Plasma BNP levels were also compared between higher and lower 1/3FF patients matched for LVEF. Plasma BNP concentrations in 1/3FF < 35% patients were significantly greater than those in 1/3FF > or = 35% patients (312.9 +/- 62.5 vs. 120.5 +/- 32.8 pg/ml, p < 0.05, both n = 14). CONCLUSIONS: The degree of LV systolic and diastolic dysfunctions evaluated by QGS correlated with that by UCG or BNP. The QGS functional parameters offer useful information regarding cardiac failure.  相似文献   

5.
PURPOSE: To investigate whether a newly developed maneuver that reduces the reconstruction area by a half more accurately evaluates left ventricular (LV) volume on quantitative gated SPECT (QGS) analysis. METHODS: The subjects were 38 patients who underwent left ventricular angiography (LVG) followed by G-SPECT within 2 weeks. Acquisition was performed with a general purpose collimator and a 64 x 64 matrix. On QGS analysis, the field magnification was 34 cm in original image (Original: ORI), and furthermore it was changed from 34 cm to 17 cm to enlarge the re-constructed image (Field Change Conversion: FCC). End-diastolic volume (EDV) and end-systolic volume (ESV) of the left ventricle were also obtained using LVG. RESULTS: EDV was 71 +/- 19 ml, 83 +/- 20 ml and 98 +/- 23 ml for ORI, FCC and LVG, respectively (p < 0.001: ORI versus LVG, p < 0.001: ORI versus FCC, p < 0.001: FCC versus LVG). ESV was 28 +/- 12 ml, 34 +/- 13 ml and 41 +/- 14 ml for ORI, FCC and LVG, respectively (p < 0.001: ORI versus LVG, p < 0.001: ORI versus FCC, p < 0.001: FCC versus LVG). CONCLUSION: FCC was better than ORI for calculating LV volume in clinical cases. Furthermore, FCC is a useful method for accurately measuring the LV volume on QGS analysis.  相似文献   

6.
PURPOSE: Present study was designed to evaluate the accuracy of the measurement of left ventricular volume by quantitative gated SPECT (QGS) software using 201T1 and the effect of cutoff frequency of Butterworth prereconstruction filter on the calculation of volume. METHODS: The RH-2 type cardiac phantom and 20 patients with ischemic heart disease were studied. Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were calculated by the QGS software using the various frequency of Butterworth filter. These parameters were evaluated by Simpson's method using left ventriculography (LVG). RESULTS: The volume of the phantom calculated by QGS was under-estimated by 14%. In the clinical study, EDV and ESV measured by QGS were smaller than those obtained from LVG by 10%. When the cutoff frequency of Butterworth filter was 0.43 cycles/cm, the values measured by QGS were best correlated with those by LVG (EDV: r = 0.80, p < 0.001; ESV: r = 0.86, p < 0.001; EF: r = 0.80, p < 0.001). CONCLUSION: These data suggest that 201Tl quantitative gated cardiac SPECT can estimate myocardial ischemia and left ventricular function simultaneously.  相似文献   

7.
We investigated the reproducibility between thallium-201 and technetium-99m methoxyisobutylisonitrile (MIBI) gated single-photon emission tomography (SPET) for the assessment of indices of myocardial function such as end-diastolic and end-systolic volume (EDV, ESV), ejection fraction (EF) and wall motion. Rest 201Tl (111 MBq) gated SPET was sequentially performed twice in 20 patients. Rest 201Tl gated SPET and rest 99mTc-MIBI (370 MBq) gated SPET were performed 24 h apart in 40 patients. Wall motion was graded using the surface display of the Cedars quantitative gated SPET (QGS) software. EDV, ESV and EF were also measured using the QGS software. The reproducibility of functional assessment on rest 201Tl gated SPET was compared with that on 99mTc-MIBI gated SPET, and also with that between 201Tl gated SPET and 99mTc-MIBI gated SPET performed on the next day. The two standard deviation (2 SD) values for EDV, ESV and EF on the Bland-Altman plot were 29 ml, 19 ml and 12%, respectively, on repeated 201Tl gated SPET, compared with 14 ml, 11 ml and 5.3% on repeated 99mTc-MIBI gated SPET. The correlations were good (r=0.96, 0.97 and 0.87) between the two measurements of EDV, ESV and EF on repeated rest studies with 201Tl and 99mTc-MIBI gated SPET. However, Bland-Altman analysis revealed that the 2 SD values between the two measurements were 31 ml, 23 ml and 12%. We were able to score the wall motion in all cases using the 3D surface display of the QGS on 201Tl gated SPET. The kappa value of the wall motion grade on the repeated 201Tl study was 0.35, while that of the wall motion grade on the repeated 99mTc-MIBI study was 0.76. The kappa value was 0.49 for grading of wall motion on repeated rest studies with 201Tl and 99mTc-MIBI. In conclusion, QGS helped determine EDV, ESV, EF and wall motion on 201Tl gated SPET. Because the EDV, ESV and EF were less reproducible on repeated 201Tl gated SPET or on 201Tl gated SPET and 99mTc-MIBI gated SPET on the next day than on repeated 99mTc-MIBI gated SPET, functional measurement on 201Tl gated SPET did not seem to be interchangeable with that on 99mTc-MIBI gated SPET.  相似文献   

8.
To evaluate the effect of left ventricular (LV) size on the calculation of LV function from gated myocardial SPECT with Emory and Cedars-Sinai programs, we performed 99mTc-tetrofosmin gated SPECT on 49 patients with ischemic heart disease. End-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) were semi-automatically calculated by each program. All patients underwent left ventriculography (LVG) within 3 months before and after the SPECT study. We grouped the patients into 22 with a calculated ESV obtained from LVG of over 50 ml (group A) and 27 with an ESV value of 50 ml or below (group B). We then compared the ESV values from gated SPECT with those from LVG in each group. In group A, the ESV from both Emory and Cedars-Sinai programs similarly correlated well with those from LVG (r = 0.92 and r = 0.93, respectively), but in group B, the ESV calculated from the Cedars-Sinai program correlated less with those from LVG (r = 0.53) than those from the Emory program did (r = 0.70). The calculated LV volumes had more errors in the Cedars-Sinai program than in the Emory program, when a patient had a small heart.  相似文献   

9.
The purpose of this study was to evaluate myocardial electrocardiography (ECG)-gated 13N-ammonia (13N-NH3) PET for the assessment of cardiac end-diastolic volume (EDV), cardiac end-systolic volume (ESV), left ventricular (LV) myocardial mass (LVMM), and LV ejection fraction (LVEF) with gated 18F-FDG PET as a reference method. METHODS: ECG-gated 13N-NH3 and 18F-FDG scans were performed for 27 patients (23 men and 4 women; mean+/-SD age, 55+/-15 y) for the evaluation of myocardial perfusion and viability. For both 13N-NH3 and 18F-FDG studies, a model-based image analysis tool was used to estimate endocardial and epicardial borders of the left ventricle on a set of short-axis images and to calculate values for EDV, ESV, LVEF, and LVMM. RESULTS: The LV volumes determined by 13N-NH3 and 18F-FDG were 108+/-60 mL and 106+/-63 mL for ESV and 175+/-71 mL and 169+/-73 mL for EDV, respectively. The LVEFs determined by 13N-NH3 and 18F-FDG were 42%+/-13% and 41%+/-13%, respectively. The LVMMs determined by 13N-NH3 and 18F-FDG were 179+/-40 g and 183+/-43 g, respectively. All P values were not significant, as determined by paired t tests. A significant correlation was observed between 13N-NH3 imaging and 18F-FDG imaging for the calculation of ESV (r=0.97, SEE=14.1, P<0.0001), EDV (r=0.98, SEE=15.4, P<0.0001), LVEF (r=0.9, SEE=5.6, P<0.0001), and LVMM (r=0.93, SEE=15.5, P<0.0001). CONCLUSION: Model-based analysis of ECG-gated 13N-NH3 PET images is accurate in determining LV volumes, LVMM, and LVEF. Therefore, ECG-gated 13N-NH3 can be used for the simultaneous assessment of myocardial perfusion, LV geometry, and contractile function.  相似文献   

10.
BACKGROUND: Two different commercially available gated single photon emission computed tomography (GSPECT) methods were compared in a population of patients with a major myocardial infarction. METHODS: Rest thallium GSPECT was performed with a 90-degree dual-detector camera, 4 hours after injection of thallium-201 (Tl-201; 185 MBq) in 43 patients (mean age, 62+/-12 years) with a large myocardial infarction (mean defect size, 33%+/-16%). End-diastolic volume (EDV), end-systolic volume (ESV), and left ventricular ejection fraction (LVEF) were calculated by using QGS (Cedars Sinai) and MultiDim (Sopha Medical Vision International, Buc, France). Images were reconstructed by using a 2.5 zoom and a Butterworth filter (order, 5; cut-off frequency, 0.20). LVEF was calculated in all patients by using equilibrium radionuclide angiocardiography (ERNA). EDV, ESV, and LVEF were also measured by using left ventriculography (LVG). RESULTS: Compared with LVG, QGS underestimated LVEF by means of an underestimation of mean EDV. MultiDim overestimated EDV and ESV. GSPECT EDV and ESV overestimation was demonstrated by means of Bland-Altman analysis to increase with left ventricular volume size (P<.05). The difference between LVG and GSPECT volumes was demonstrated by means of regression analysis to be correlated with infarction size. This effect was particularly important with MultiDim (P<.0001). CONCLUSION: In Tl-201 GSPECT, LVEF and volume measurements will vary according to the type of software used.  相似文献   

11.
A scintillator-photodiode camera is able to acquire single photon emission computed tomography (SPECT) images by using a rotating chair system. We validated the left ventricular (LV) parameters of this camera system utilizing a dynamic myocardial phantom. Gated myocardial SPECT of a dynamic myocardial phantom (Hokkaido University type; end diastolic volume (EDV), 143 ml; end systolic volume (ESV), 107 ml; ejection fraction (EF), 25%) was performed with this scintillation camera. LV parameters were calculated using pre-installed software (Mirage Myocardial Perfusion SPECT) (study 1) and the other software (QGS; Cedars-Sinai) (study 2). For comparison, SPECT from a traditional Anger camera were processed by the QGS software (study 3). The estimated volumes were similar among the three studies (EDV, 110+/-8 ml in study 1, 112+/-2 ml in study 2 and 111+/-1 ml in study 3; ESV, 86+/-8 ml in study 1, 93+/-4 ml in study 2 and 91+/-2 ml in study 3). The estimated EFs were 23+/-3%, 17+/-2%, and 18+/-1%, respectively. The calculated volume within each study was underestimated by approximately the same degree. However, each estimated EF value for each study was close to the actual value. The estimated LV function using the scintillator-photodiode camera system may be considered as a suitable alternative to the traditional Anger camera system.  相似文献   

12.
BACKGROUND: We compared the reproducibility of thallium 201 and technetium 99m sestamibi (MIBI) gated single photon emission computed tomography (SPECT) measurement of myocardial function using the Germano algorithm (J Nucl Med 1995;36:2138-47). METHODS AND RESULTS: Gated SPECT acquisition was repeated in the same position in 30 patients who received Tl-201 and in 26 who received Tc-99m-MIBI. The quantification of end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) on Tl-201 and Tc-99m-MIBI gated SPECT was processed independently with Cedars-Sinai QGS (Quantitative Gated SPECT) software. The reproducibility of the measurement of ventricular function on Tl-201 gated SPECT was compared with that of Tc-99m-MIBI gated SPECT. Correlation between the 2 measurements for volumes and EF was excellent for the repeated gated SPECT studies of Tl-201 (r = 0.928 to 0.986, P <.05) and Tc-99m-MIBI (r = 0.979 to 0.997, P <.05). However, Bland-Altman analysis revealed the 95% limits of agreement (2 SDs) for volumes and EF were narrower by repeated Tc-99m-MIBI gated SPECT (EDV 14.1 mL, ESV 9.4 mL, EF 5.5%) than by repeated Tl-201 gated SPECT (EDV 24.1 mL, ESV 18.6 mL, EF 10.3%). The root-mean-square values of the coefficient of variation for volumes and EF were smaller by repeated Tc-99m-MIBI gated SPECT (EDV 2.1 mL, ESV 2.7 mL, EF 2.3%) than by repeated Tl-201 gated SPECT (EDV 3.2 mL, ESV 3.5 mL, EF 5.2%). CONCLUSIONS: QGS provides an excellent correlation between repeated gated SPECT with Tl-201 and Tc-99m-MIBI. However, Tc-99m-MIBI provides more reproducible volumes and EF than Tl-201. Tc-99m-MIBI gated SPECT is the preferable method for the clinical monitoring of ventricular function.  相似文献   

13.
OBJECTIVE: Intraindividual comparison of right ventricular volumes and function using electron beam computed tomography (EBT) and magnetic resonance imaging (MRI). METHODS: Twenty-seven patients with a known cardiac history were referred for evaluation of ventricular function parameters. The following standardized protocols were used: contrast-enhanced multislice mode EBT and gradient echo sequence MRI. Right ventricular end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) were calculated using a slice summation method. Interobserver variability was calculated. RESULTS: The correlation between the 2 methods was: r = 0.901 for EDV, r = 0.938 for ESV, r = 0.823 for SV, and r = 0.953 for EF. Electron beam computed tomography overestimated EDV and ESV slightly when compared with MRI (P < 0.05). No significant differences (P > 0.05) were found between SV and EF. Mean values determined by EBT and MRI were as follows: 168.6 +/- 62.3 mL and 153.7 +/- 59.1 mL for EDV, 104.7 +/- 60.4 mL and 95.1 +/- 54.8 mL for ESV, 63.2 +/- 19.3 mL and 58.7 +/- 19.8 mL for SV, and 40.2% +/- 14.1% and 40.2% +/- 13.6% for EF, respectively. Interobserver variability ranged between 1.0% and 3.2%. CONCLUSION: Electron beam computed tomography shows good agreement with a close correlation and an acceptable interobserver variability for right ventricular volumes and global function, with a small but significant overestimation of EDV and ESV when compared with MRI.  相似文献   

14.
The aim of this study was to assess the changes in hemodynamic function and myocardial perfusion of the left ventricle occurring in patients with type 1 diabetes mellitus (DM1) 47-49 months after the first assessment. We have studied 20 asymptomatic patients, five females and 15 males, aged 22-46 y. The patients were under intensive insulin treatment and had normal electrocardiogram (ECG) at rest. In all patients gated single photon emission tomography (GSPET) was performed at rest and after exercise (examination I). After 47-49 months this test was repeated (examination II). GSPET was performed 60 min after the intravenous injection of 740 MBq of technetium-99m 2-methoxy-isobutyl-isonitrile ((99m)Tc-MIBI), using a dual-headed gamma-camera. Left ventricular ejection fraction (LVEF), end diastolic volume (EDV) and end systolic volume (ESV) were calculated using quantitative GSPET (QGS). The intensity of perfusion defects was also evaluated based on a four degree QGS scale. Our results were as follows: a) In examination I, performed at rest: LVEF was 56.1%+/-7.5%, EDV 96.9+/-25.8 ml and ESV 42.6+/-16.3 ml. b) In examination I at stress: LVEF was 57.2%+/-7.5%, EDV 94.1+/-24.0 ml and ESV 40.5+/-15.5. c) In examination II performed at rest: LVEF was 58.1%+/-6.5%, EDV 112.1+/-26.1 ml and ESV 46.6+/-14.9 ml and d) In examination II at stress: LVEF 57.8%+/-5.6%, EDV 107.9+/-27.4 ml and ESV 44.9+/-14.4 ml. Significant differences were found between examinations I and II, regarding: a) EDV at rest (P<0.001) and at stress (P<0.001) and b) ESV at rest (P<0.05) and at stress (P<0.005). Correlation analysis revealed significant correlation between LVEF at rest and at stress both in examination I (r=0.83; P<0.001) and also in examination II (r=-0.897; P<0.001). Intensity of myocardial perfusion defects in examination I at rest and at stress was: 1.68+/-0.5 and 2.2+/-0.6 degrees respectively. Intensity of myocardial perfusion defects in examination II at rest and at stress was: 1.75+/-0.4 and 2.2+/-0.5 respectively. No significant differences in the intensity of these perfusion defects were found. EDV both at rest and at stress was significantly higher in examination II as compared with the examination I study. Similar, but less pronounced changes of ESV were found. This study confirms other authors' observations on LV, EDV and LV, ESV and also that the percentage of asymptomatic DM1 patients having silent myocardial ischemia is high as was in all our patients. Nevertheless, in the current literature, we were unable to find a study similar to the present one, comparing basal and after four years LV functional GSPET data, in asymptomatic DM1 patients. In conclusion, myocardial perfusion GSPET was useful as a screening test in DM1 patients in showing four years after the basal study, prodromal signs of cardiovascular disease, especially increase of left ventricular volumes and silent myocardial ischemia, in these patients. Our research on the above protocol is being continued.  相似文献   

15.
BACKGROUND: The most widely distributed software packages to compute left ventricular (LV) volume and ejection fraction (EF) from gated perfusion tomograms are QGS and the Emory Cardiac Toolbox (ECTb). Because LV modeling and time sampling differ between the algorithms, it is necessary to document relationships between values produced by them and to establish normal limits individually for each software package in order to interpret results obtained for individual patients. METHODS AND RESULTS: Gated single photon emission computed tomography technetium 99m sestamibi myocardial perfusion studies were collected and analyzed for 246 patients evaluated for coronary artery disease. QGS and ECTb values of ejection fraction (EF), end-diastolic volume (EDV), and end-systolic volume were found to correlate linearly (r = 0.90, 0.91, and 0.94, respectively), but EF and EDV were significantly lower for QGS than with ECTb (53% +/- 13% vs 61% +/- 13 and 102 +/- 45 mL vs 114 +/- 50 mL, respectively). To compare calculations for healthy subjects between the two software packages, data were also selected for 50 other patients at low likelihood for coronary artery disease, for whom EF and EDV were significantly lower for QGS compared with ECTb (62% +/- 9% vs 67% +/- 8% and 84 +/- 26 mL vs 105 +/- 33 mL, respectively). The ECTb lower limit was 51% for EF and the upper limits were 171 mL for EDV and 59 mL/m(2) for mass-indexed EDV, compared with limits of 44%, 137 mL, and 47 mL/m(2) for QGS. CONCLUSIONS: Although correlations were strong between the two methods of computing LV functional values, statistical scatter was substantial and significant biases and trends observed. Therefore, when both software packages are used at the same site, it will be important to take these differences into consideration and to apply normal limits specific to each set of algorithms.  相似文献   

16.
PURPOSES: ECG-gated myocardial SPECT program (QGS) is coming into wide use. This program permits measurement of end-diastolic volume (EDV), and end-systolic volume (ESV) and ejection fraction (EF) by automatic detection of myocardial edges. We assessed the reproducibility, accuracy, factors that affect the measurement of these indices using a cardiac phantom and clinical data. METHODS: In the phantom study, we evaluated the effects of ventricular volume, location, absorption, acquisition time, enlarged acquisition and pre-filter on the calculated indices. In the clinical study using 99mTc-MIBI, reproducibility between 2 observers, comparison with left ventriculography and effects of pre-filter were assessed. In clinical cases of 201TI and 123I-BMIPP, left ventricular volume and EF were also analyzed by QGS with various pre-filters. RESULTS: Although the true phantom volumes (y) and calculated volumes (x) showed an excellent linear correlation (y = 0.94x - 13.8, r = 0.999), calculated volumes were significantly under-estimated by 14.5-33.8%. An absorbent material around the phantom caused reduction in calculated volumes by 4.1-9.1%. Duration of acquisition times, 3 to 60 seconds per projection, did not influence the calculation of the parameters. With enlarged data collection, calculated volume (37 ml) was larger than that of normal acquisition (33 ml). When the cut-off frequency of Butterworth filter was changed, these indices of volume and EF were almost stable over 0.41 cycle/cm. There was an excellent correlation in intra-observer measurements for EDV (r = 0.998, p < 0.0001), ESV (r = 0.998, p < 0.0001) and EF (r = 0.995, p < 0.0001). In comparison with left ventriculography, correlation of parameters was good in ESV (r = 0.91, p < 0.0001), EF (r = 0.88, p < 0.0001), but was fair in EDV (r = 0.78, p < 0.0001). The QGS program underestimated EDV, ESV and EF. CONCLUSION: QGS program with gated SPECT is useful to calculate relative volume and EF. However, to calculate absolute values, we should understand the various factors that affect the result of QGS.  相似文献   

17.
The purpose of this study was to verify whether the accuracy of left ventricular parameters related to left ventricular function from gated-SPECT improved or not, using multivariate analysis. METHODS: Ninety-six patients with cardiovascular diseases were studied. Gated-SPECT with the QGS software and left ventriculography (LVG) were performed to obtain left ventricular ejection fraction (LVEF), end-diastolic volume (EDV) and end-systolic volume (ESV). Then, multivariate analyses were performed to determine empirical formulas for predicting these parameters. The calculated values of left ventricular parameters were compared with those obtained directly from the QGS software and LVG. RESULTS: Multivariate analyses were able to improve accuracy in estimation of LVEF, EDV and ESV. Statistically significant improvement was seen in LVEF (from r = 0.6965 to r = 0.8093, p < 0.05). Although not statistically significant, improvements in correlation coefficients were seen in EDV (from r = 0.7199 to r = 0.7595, p = 0.2750) and ESV (from r = 0.5694 to r = 0.5871, p = 0.4281). CONCLUSION: The empirical equations with multivariate analysis improved the accuracy in estimating LVEF from gated-SPECT with the QGS software.  相似文献   

18.
BACKGROUND AND AIM: The Cedars-Sinai Quantitative Gated Single Photon Emission Computed Tomography (SPECT) (QGS) program, used to quantify left ventricular function parameters from gated myocardial perfusion scintigraphy (MPS), has been extensively validated and compared with other methods of quantification. However, little is known about the reproducibility of QGS on different processing systems. This study compared the findings of QGS running on workstations provided by two different manufacturers. METHODS: Gated rest MPS studies of 50 patients were analysed retrospectively. Filtered back-projection (FBP) was performed using identical parameters on Philips Pegasys and Nuclear Diagnostics Hermes workstations to produce gated short-axis (SA) slices. In addition, the gated SA slices reconstructed on the Pegasys were transferred to the Hermes. QGS was used to calculate the end-diastolic volume (EDV), end-systolic volume (ESV) and left ventricular ejection fraction (LVEF) in each case. RESULTS: The mean+/-standard deviation differences between the Pegasys and Hermes function parameters were -7.06+/-3.91 ml (EDV), -5.54+/-3.21 ml (ESV) and +1.14%+/-1.43% (LVEF) when data were reconstructed on different systems, and -0.16+/-1.58 ml (EDV), -0.10+/-1.02 ml (ESV) and +0.14%+/-0.73% (LVEF) when data were reconstructed on the same system. Bland-Altman plots showed definite trends for EDV and ESV for data reconstructed on different systems, but no trends were seen for data reconstructed on the same system. CONCLUSIONS: When data were reconstructed on two separate systems, the difference between the function parameters obtained from Pegasys and Hermes could be ascribed to differences in the reconstruction process on each system despite the use of identical parameters (filters, etc). However, when the same reconstructed data were analysed on both systems, no significant difference in left ventricular function parameters was observed.  相似文献   

19.
Background  Some studies suggested that the poststress left ventricle ejection fraction (LV EF) is lower than rest LV EF in patients with stress-induced ischemia. Methods and Results  By using a 2-day protocol and 30 mCi Tc-99m sestamibi, LV EF, end-systolic volume (ESV), and end-diastolic volume (EDV) were measured with gated SPECT. Of 99 eligible patients, 91 had technically adequate studies. Poststress LV EF minus rest LV EF was defined as ΔLV EF. ΔEDV and ΔESV were similarly defined. Rest and poststress LV EF (r = 0.89), EDV (r = 0.78), and ESV (r = 0.93) were highly correlated (P <.001). Rest LV EF, EDV, and ESV were not significantly different between patients with and without stress-induced ischemia. ΔLV EF was significantly lower in patients with stress-induced ischemia (-3.5% ± 4.5% vs -1.1% ± 4.7%, P ± .02). Mean LV EF poststress in ischemic patients was 55.0% ± 10.5% vs 61.2% ± 10.0% in nonischemic patients (P = .008). However, only 1 patient (3%) with ischemia had ΔLV EF that exceeded the 95% confidence limit of ΔLV EF for normal patients. Ischemia was significantly associated with increased ΔEDV and ΔESV (P <.01). Conclusions  Stress-induced ischemia is associated with poststress reduction in LV EF and increased poststress EDV and ESV. However, the effect of ischemia on the difference between poststress and rest EF measurements is modest and rarely exceeds the confidence limits in normal patients undergoing 2-day protocols. In most patients, poststress LV EF is an accurate reflection of rest LV EF.  相似文献   

20.
It is stated that cardiac MRI imaging can provide accurate estimation of left ventricular (LV) volumes and ejection fraction (EF). The purpose of this study was to evaluate the accuracy of gated myocardial perfusion SPECT for assessment of LV end-diastolic volume (EDV), end-systolic volume (ESV) and EF, using cardiac MRI as the reference methods/(methodology). Gated myocardial perfusion SPECT images were analyzed with two different quantification software, QGS and 4D-MSPECT. Thirty-four consecutive patients were studied. Myocardial perfusion SPECT and cardiac MRI had excellent intra/interobserver reproducibility. Correlation between the results of gated myocardial perfusion SPECT and cardiac MRI were high for EDV and EF. However, ESV and EDV were significantly underestimated by gated myocardial perfusion SPECT compared to cardiac MRI. Moreover, gated myocardial perfusion SPECT overestimated EF for small heart. One reason for the difference in volumes and EF is the delineation of the endocardial border. Cardiac MRI has higher spatial resolution. We should understand the differences of volumes and EF as determined by gated myocardial perfusion SPECT and cardiac MRI.  相似文献   