 共查询到20条相似文献,搜索用时 171 毫秒
1.
OBJECTIVE: To evaluate the impact of low-threshold compression and hearing aid style (in-the-ear [ITE] versus behind-the-ear [BTE]) on the directional benefit and performance of commercially available directional hearing aids. DESIGN: Forty-seven adult listeners with mild-to-moderate sensorineural hearing loss were fit bilaterally with one BTE and four different ITE hearing aids. Speech recognition performance was measured through the Connected Speech Test (CST) and Hearing in Noise Test (HINT) for a simulated noisy restaurant environment. RESULTS: For both the HINT and CST, speech recognition performance was significantly greater for subjects fit with directional in comparison with omnidirectional microphone hearing aids. Performance was significantly poorer for the BTE instrument in comparison with the ITE hearing aids when using omnidirectional microphones. No differences were found for directional benefit between compression and linear fitting schemes. CONCLUSIONS: No systematic relationship was found between the relative directional benefit and hearing aid style; however, the speech recognition performance of the subjects was somewhat predictable based on Directivity Index measures of the individual hearing aid models. The fact that compression did not interact significantly with microphone type agrees well with previously reported electroacoustic data.  相似文献   

2.
Ricketts T 《Ear and hearing》2000,21(4):318-328
OBJECTIVE: To evaluate the impact of head turn and monaural and binaural fittings on the sentence reception thresholds of hearing-impaired listeners wearing directional and omnidirectional hearing aids. DESIGN: Sentence reception thresholds were measured for 20 listeners fit monaurally and binaurally with behind-the-ear hearing aids set in both directional and omnidirectional modes. All listeners exhibited symmetrical, sloping, sensorineural hearing loss. The aided performance across these four fittings was evaluated for three different head and body angles. The three angles reflected body turns of 0 degrees, 15 degrees, and 30 degrees as measured relative to the primary sound source, with 0 degrees denoting the listener directly facing the sound source. Listeners were instructed to keep their heads in a fixed horizontal position and turn their heads and bodies to face visual targets at the three test angles. Sentences from the Hearing in Noise Test presented with a background of five, spatially separated, uncorrelated samples of cafeteria noise served as test material. All testing was performed in a moderately reverberant (Rt = 631 msec) "living room" environment. RESULTS: Participants generally performed significantly better when fit with directional versus omnidirectional hearing aids, and when fit binaurally versus monaurally across test conditions. The measured "binaural advantage" was reduced with increasing head angle. Participants performed significantly better with a 30 degree head angle than when directly facing the primary speaker. This "head turn advantage" was most prominent for monaural (versus binaural) conditions. Binaural and head turn advantages were not significantly different across directional and omnidirectional modes. CONCLUSIONS: These data provide additional support for the use of directional hearing aids and binaural amplification to improve speech intelligibility in noisy environments. The magnitude of these advantages was similar to that reported in previous investigations. The data also showed that hearing aid wearers achieved significantly better speech intelligibility in noise by turning their heads and bodies to a position in which they were not directly facing the sound source. This head turn advantage was in good agreement with the increase in Directivity Index with head turn and reflected the fact that hearing aids are generally most sensitive to sounds arriving from angles other than directly in front of the hearing aid wearer. Although these data suggest that many monaural hearing aid wearers may significantly improve speech intelligibility in noise through the use of head turn, the interaction between this advantage and the potential loss of visual cues with head turn is unknown.  相似文献   

3.
The effectiveness of adaptive directional processing for improvement of speech recognition in comparison to non-adaptive directional and omni-directional processing was examined across four listening environments intended to simulate those found in the real world. The test environment was a single, moderately reverberant room with four loudspeaker configurations: three with fixed discrete noise source positions and one with a single panning noise source. Sentence materials from the Hearing in Noise Test (HINT) and Connected Speech Test (CST) were selected as test materials. Speech recognition across all listening conditions was evaluated for 20 listeners fitted binaurally with Phonak Claro behind-the-ear (BTE) style hearing aids. Results indicated improved speech recognition performance with adaptive and non-adaptive directional processing over that measured with the omnidirectional processing across all four listening conditions. While the magnitudes of directional benefit provided to subjects listening in adaptive and fixed directional modes were similar in some listening environments, a significant speech recognition advantage was measured for the adaptive mode in specific conditions. The advantage for adaptive over fixed directional processing was most prominent when a competing noise was presented from the listener's sides (both fixed and panning noise conditions), and was partially predictable from electroacoustically measured directional pattern data.  相似文献   

4.
OBJECTIVE: The purpose of this experiment was to systematically examine hearing aid benefit as measured by speech recognition and self-assessment methods across omnidirectional and directional hearing aid modes. These data were used to compare directional benefit as measured by speech recognition in the laboratory to hearing aid wearer's perceptions of benefit in everyday environments across full-time directional, full-time omnidirectional, and user selectable directional fittings. Identification of possible listening situations that resulted in different self reported hearing aid benefit as a function of microphone type was a secondary objective of this experiment. DESIGN: Fifteen adults with symmetrical, sloping sensorineural hearing loss were fitted bilaterally with in-the-ear (ITE) directional hearing aids. Measures of hearing aid benefit included the Profile of Hearing Aid Benefit (PHAB), the Connected Sentence Test (CST), the Hearing in Noise Test (HINT), and a daily use log. Additionally, two new subscales were developed for administration with the PHAB. These subscales were developed to specifically address situations in which directional hearing aids may provide different degrees of benefit than omnidirectional hearing aids. Participants completed these measures in three conditions: omnidirectional only (O), directional only with low-frequency gain compensation (D), and user-selectable directional/omnidirectional (DO). RESULTS: Results from the speech intelligibility in noise testing indicated significantly more hearing aid benefit in directional modes than omnidirectional. PHAB results indicated more benefit on the background noise subscale (BN) in the DO condition than in the O condition; however, this directional advantage was not present for the D condition. Although the reliability of the newly proposed subscales is as yet unknown, the data were interpreted as revealing a directional advantage in situations where the signal of interest was in front of the participant and a directional disadvantage in situations where the signal of interest was behind the listener or localization was required. CONCLUSIONS: Laboratory directional benefit is reflected in self-assessment measures that focus on listening in noise when the sound source of interest is in front of the listener. The use of a directional hearing aid mode; however, may have either a positive, a neutral, or a negative impact on hearing aid benefit measured in noisy situations, depending on the specific listening situation.  相似文献   

5.
The purpose of this study was to assess the relationship between the directivity of a directional microphone hearing aid and listener performance. Hearing aids were fit bilaterally to 19 subjects with sensorineural hearing loss, and five microphone conditions were assessed: omnidirectional, cardioid, hypercardioid, supercardioid, and "monofit," wherein the left hearing aid was set to omnidirectional and the right hearing aid to hypercardioid. Speech perception performance was assessed using the Hearing in Noise Test (HINT) and the Connected Speech Test (CST). Subjects also assessed eight domains of sound quality for three stimuli (speech in quiet, speech in noise, and music). A diffuse soundfield system composed of eight loudspeakers forming the corners of a cube was used to output the background noise for the speech perception tasks and the three stimuli used for sound quality judgments. Results indicated that there were no significant differences in the HINT or CST performance, or sound quality judgments, across the four directional microphone conditions when tested in a diffuse field. Of particular interest was the monofit condition: Performance on speech perception tests was the same whether one or two directional microphones were used.  相似文献   

6.
The improvement in speech recognition in noise obtained with directional microphones compared to omnidirectional microphones is referred to as the directional advantage. Laboratory studies have revealed substantial differences in the magnitude of the directional advantage across hearing-impaired listeners. This investigation examined whether persons who were successful users of directional microphone hearing aids in everyday living tended to obtain a larger directional advantage in the test booth than persons who were unsuccessful users. Results revealed that the mean directional advantage did not differ significantly between patients who used the directional mode regularly and those who reported little or no benefit from directional microphones in daily living and, therefore, tended to leave their hearing aids set in the default omnidirectional mode. Success with directional microphone hearing aids in everyday living, therefore, cannot be reliably predicted by the magnitude of the directional advantage obtained in the clinic.  相似文献   

7.
OBJECTIVE: The purpose of the current investigation was to systematically examine two of the assumptions central to the application of Articulation Index weighted Directivity Index (AI-DI) to the prediction of directional benefit across three groups of listeners differentiated by degree and configuration of hearing loss. Specifically, the assumption that (1) changes in speech recognition performance are predictable from frequency specific changes in calculated audibility after applying directivity index (DI) values and (2) applying appropriate frequency importance functions would increase the accuracy of AI-DI predictions of directional benefit were evaluated. DESIGN: The output of a single hearing aid for a speech in noise input was recorded to produce high and low directivity (directional and omnidirectional microphone modes) segments. These segments were then high-pass and low-pass filtered into low- and high-frequency regions and acoustically mixed to generate the eight frequency-specific directivity combinations. All recordings were made through an acoustic manikin placed in a single room, surrounded by five uncorrelated noise sources. The aided sentence recognition, in noise, for three groups of 12 adult participants with symmetrical sensorineural hearing impairment, was then measured across the eight listening conditions. The three groups were differentiated by degree and type of hearing loss including "sloping," "flat," and "severe" configurations.The frequency-specific DI values for each of the eight listening conditions were applied to the calculation of frequency specific noise levels. These corrected noise levels were then used to calculate an Articulation Index using the Speech Intelligibility Index (SII, ). These SII values were then compared with measured speech recognition under the same eight listening conditions.Directional benefit values were then calculated by subtracting the performance of individual participants on the Connected Speech Test (CST) in omnidirectional mode from performance in all other filter conditions. The changes in average DI and AI-DI (using three different frequency importance functions) that existed between omnidirectional and the other seven filter conditions were then calculated for comparison to directional benefit values. RESULTS: The speech recognition data revealed a complex interaction between filter condition and group. Despite this interaction, highly significant positive correlations were found between participants' speech recognition scores and the corresponding SII calculation for all three hearing loss groups.Individual subjects' measured directional benefit was highly correlated with changes in DI. Similar correlations were found for average DI and all three AI-DI weighting methods. CONCLUSIONS: As expected, performance and calculated SII values were in good agreement across conditions supporting the hypothesis that DI provides a reasonable frequency-specific estimate of signal-to-noise ratio changes in the test environment. The results further support the use of AI-DI or average DI for prediction of directional benefit. The choice of importance weighting across frequency (flat or frequency importance function based), however, did not improve the accuracy of these predictions; therefore, a simple average DI is advocated. Further, the prediction of absolute directional benefit across hearing loss groups from traditional AI-DI calculations may lead to error if the negative effects of hearing loss on speech understanding, and how these effects vary with degree of hearing loss, are not considered as a contributing factor.  相似文献   

8.
In this study, two types of hearing aids were used. Both aids had the same frequency characteristics for frontal sound, but one employed an omnidirectional microphone and the other a directional microphone. The frequency characteristics of both hearing aids were measured for five azimuths on KEMAR and in situ in 12 normal-hearing subjects. For these subjects we also determined the speech reception threshold (SRT) with background noise in two rooms with different reverberation times. The direction of the speech stimuli was always frontal; the direction of the noise was varied. Additionally, directional hearing was measured with short noise bursts from eight loudspeakers surrounding the subject. In the less reverberant room, sounds coming from behind were less amplified by the hearing aid with the directional microphone than by the one with the omnidirectional microphone. In this room the monaural SRT values were largely determined by the level of the background noise. For the directional hearing aids there was an extra binaural advantage which depended on the direction of the background noise. Only for low-frequency noise bursts was directional hearing better with directional hearing aids. In the more reverberant room, no distinct differences between the frequency characteristics of the two hearing aid types were measured. However, a systematic difference between monaural SRT values measured through the two hearing aids was found. This difference was independent of noise azimuth. In conclusion, hearing aid(s) with a directional microphone showed no disadvantages and clear advantages under specific conditions.  相似文献   

9.
The efficacy of a digital hearing aid with a directional microphone was examined in a school-aged population. Twenty children (9 with a mild-to-moderately-severe hearing loss and 11 with a moderate-to-severe hearing loss) between 7 1/2 and 13 2/3 years of age wore the study hearing aids binaurally for 30 days prior to the evaluation. The testing protocol included speech recognition tests using the CID W-22 word lists presented at 72 dB SPL, 65 dB SPL, and 52 dB SPL (at 0 degrees azimuth) in the presence of a 65 dB SPL party noise (180 degrees azimuth). Subjective rating of hearing aid efficacy in the classroom was examined using the Listening Inventory For Education (LIFE) questionnaire. Parental impression on hearing aid efficacy was also collected at the end of the study. The results showed improved speech recognition in noise with the digital directional hearing aid at all presentation levels. Preference for the digital directional hearing aids over the subjects' own omnidirectional analog hearing aids was also seen on the LIFE questionnaire and parental impression. The degree of hearing loss did not seem to have affected the benefits offered by the digital directional hearing aids. These results were compared to results from other studies on the use of directional microphones in hearing aids.  相似文献   

10.
OBJECTIVE: The benefits of directional processing in hearing aids are well documented in laboratory settings. Likewise, substantial research has shown that speech understanding is optimized in many settings when listening binaurally. Although these findings suggest that speech understanding would be optimized by using bilateral directional technology (e.g., a symmetric directional fitting), recent research suggests similar performance with an asymmetrical fitting (directional in one ear and omnidirectional in the other). The purpose of this study was to explore the benefits of using bilateral directional processing, as opposed to an asymmetric fitting, in environments where the primary speech and noise sources come from different directions. DESIGN: Sixteen older adults with mild-to-severe sensorineural hearing loss (SNHL) were recruited for the study. Aided sentence recognition using the Hearing in Noise Test (HINT) was assessed in a moderately reverberant room, in three different speech and noise conditions in which the locations of the speech and noise sources were varied. In each speech and noise condition, speech understanding was assessed in four different microphone modes (bilateral omnidirectional mode; bilateral directional mode; directional mode left and omnidirectional mode right; omnidirectional mode left and directional mode right). The benefits and limitations of bilateral directional processing were assessed by comparing HINT thresholds across the various symmetric and asymmetric microphone processing conditions. RESULTS: Study results revealed directional benefit varied based on microphone mode symmetry (i.e., symmetric versus asymmetric directional processing) and the specific speech and noise configuration. In noise configurations in which the speech was located in the front of the listener and the noise was located to the side or surrounded the listener, maximum directional benefit (approximately 3.3 dB) was observed with the symmetric directional fitting. HINT thresholds obtained when using bilateral directional processing were approximately 1.4 dB better than when an asymmetric fitting (directional processing in only one ear) was used. When speech was located on the side of the listener, the use of directional processing on the ear near the speech significantly reduced speech understanding. CONCLUSIONS: Although directional benefit is present in asymmetric fittings, the use of bilateral directional processing optimizes speech understanding in noise conditions in which the speech comes from in front of the listener and the noise sources are located to the side of or surround the listener. In situations in which the speech is located to the side of the listener, the use of directional processing on the ear adjacent to the speaker is likely to reduce speech audibility and thus degrade speech understanding.  相似文献   

11.
This study examined speech intelligibility and preferences for omnidirectional and directional microphone hearing aid processing across a range of signal-to-noise ratios (SNRs). A primary motivation for the study was to determine whether SNR might be used to represent distance between talker and listener in automatic directionality algorithms based on scene analysis. Participants were current hearing aid users who either had experience with omnidirectional microphone hearing aids only or with manually switchable omnidirectional/directional hearing aids. Using IEEE/Harvard sentences from a front loudspeaker and speech-shaped noise from three loudspeakers located behind and to the sides of the listener, the directional advantage (DA) was obtained at 11 SNRs ranging from -15 dB to +15 dB in 3 dB steps. Preferences for the two microphone modes at each of the 11 SNRs were also obtained using concatenated IEEE sentences presented in the speech-shaped noise. Results revealed that a DA was observed across a broad range of SNRs, although directional processing provided the greatest benefit within a narrower range of SNRs. Mean data suggested that microphone preferences were determined largely by the DA, such that the greater the benefit to speech intelligibility provided by the directional microphones, the more likely the listeners were to prefer that processing mode. However, inspection of the individual data revealed that highly predictive relationships did not exist for most individual participants. Few preferences for omnidirectional processing were observed. Overall, the results did not support the use of SNR to estimate the effects of distance between talker and listener in automatic directionality algorithms.  相似文献   

12.
OBJECTIVE: Understanding the potential benefits and limitations of directional hearing aids across a wide range of listening environments is important when counseling persons with hearing loss regarding realistic expectations for these devices. The purpose of this study was to examine the impact of speaker-to-listener distance on directional benefit in two reverberant environments, in which the dominate noise sources were placed close to the hearing aid wearer. In addition, speech transmission index (STI) measures made in the test environments were compared to measured sentence recognition to determine if performance was predictable across changes in distance, reverberation and microphone mode. DESIGN: The aided sentence recognition, in noise, for fourteen adult participants with symmetrical sensorineural hearing impairment was measured in six environmental conditions in both directional and omnidirectional modes. A single room, containing four uncorrelated noise sources served as the test environment. The room was modified to exhibit either low (RT60 = 0.3 sec) or moderate (RT60 = 0.9 sec) levels of reverberation. Sentence recognition was measured in both reverberant environments at three different speech loudspeaker-to-listener distances (1.2 m, 2.4 m, and 4.8 m). STI measures also were made in each of the 12 listening conditions (2 microphone modes x 3 distances x 2 reverberation environments). RESULTS: A decrease in directional benefit was measured with increasing distance in the moderate reverberation condition. Although reduced, directional benefit was still present in the moderately reverberant environment at the farthest speech speaker-to-listener distance tested in this experiment. A similar decrease with increasing speaker-to-listener distance was not measured in the low reverberation condition. The pattern of average sentence recognition results across varying distances and two different reverberation times agreed with the pattern of STI values measured under the same conditions. CONCLUSIONS: Although these data support increased directional benefit in noise for reduced speaker-to-listener distance, some benefit was still obtained by listeners when listening beyond "effective" critical distance under conditions of low (300 msec) to moderate (900 msec) reverberation. It is assumed that the directional benefit was due to the reduction of the direct sound energy from the noise sources near the listener. The use of aided STI values for the prediction of average word recognition across listening conditions that differ in reverberation, microphone directivity, and speaker-to-listener distance also was supported.  相似文献   

13.
The fitting of directional microphone hearing aids is becoming increasingly more routine, and this fitting option has proven to be a successful method to improve speech intelligibility in many noisy listening environments. Data suggest, however, that some hearing-impaired listeners receive significantly more directional benefit than others. It is of interest, therefore, to determine if directional benefit is predictable from identifiable audiologic factors. In this report, we examined whether the slope of audiometric configuration, amount of high-frequency hearing loss, and/or the aided omnidirectional performance for a speech-in-noise intelligibility task could be used to predict the magnitude of directional hearing aid benefit. Overall results obtained from three separate investigations revealed no significant correlation between the slope of audiometric configuration or amount of high-frequency hearing loss and the benefit obtained from directional microphone hearing instruments. Although there was a significant, negative relationship between aided omnidirectional performance and the directional benefit obtained in one study, there was considerable variability among individual participants, and nearly all of the listeners with the best omnidirectional hearing aid performance still received significant additional benefit from directional amplification. These results suggest that audiologists should consider the use of directional amplification for patients regardless of audiogram slope, high-frequency hearing loss, or omnidirectional speech intelligibility score.  相似文献   

14.
OBJECTIVE: To evaluate the impact of venting, microphone port orientation, and compression on the electroacoustically measured directivity of directional and omnidirectional behind-the-ear hearing aids. In addition, the average directivity provided across three brands of directional and omnidirectional behind-the-ear hearing aids was compared with that provided by the open ear. DESIGN: Three groups of hearing aids (four instruments in each group) representing three commercial models (a total of 12) were selected for electroacoustic evaluation of directivity. Polar directivity patterns were measured and directivity index was calculated across four different venting configurations, and for five different microphone port angles. All measurements were made for instruments in directional and omnidirectional modes. Single source traditional, and two-source modified front-to-back ratios were also measured with the hearing aids in linear and compression modes. RESULTS: The directivity provided by the open (Knowles Electronics Manikin for Acoustic Research) ear was superior to that of the omnidirectional hearing aids in this study. Although the directivity measured for directional hearing aids was significantly better than that of omnidirectional models, significant variability was measured both within and across the tested models both on average and at specific test frequencies. Both venting and microphone port orientation affected the measured directivity. Although compression reduced the magnitude of traditionally measured front-to-back ratios, no difference from linear amplification was noted using a modified methodology. CONCLUSIONS: The variation in the measured directivity both within and across the directional microphone hearing aid brands suggests that manufacturer's specification of directivity may not provide an accurate index of the actual performance of all individual instruments. The significant impact of venting and microphone port orientation on directivity indicate that these variables must be addressed when fitting directional hearing aids on hearing-impaired listeners. Modified front-to-back ratio results suggest that compression does not affect the directivity of hearing aids, if it is assumed that the signal of interest from one azimuth, and the competing signal from a different azimuth, occur at the same time.  相似文献   

15.
Omnidirectional, supercardioid, and adaptive directional microphones (ADM) were evaluated in combination with the ADRO amplification scheme for eight participants with moderate sloping hearing losses. The ADM produced better speech perception scores than the other two microphones in all noise conditions. Participants performed the Hearing in Noise Test sentences at -4.5 dB SNR or better, which is similar to the level achievable with normal hearing. The Speech, Spatial and Qualities of Hearing Scale indicated no disadvantages of using the ADM relative to the omnidirectional microphone in real-life situations. The ADM was preferred over the omnidirectional microphone in 54% of situations, compared to 17% preferences for the omnidirectional microphone, and 29% no preference. The combination of the ADM to improve SNR, and ADRO to keep the signal output comfortable and audible provided near-normal hearing performance for people with moderate hearing loss. The ADM is the recommended microphone configuration for ADRO hearing aids.  相似文献   

16.
In this study speech intelligibility in background noise was evaluated with 10 binaural hearing-aid users for hearing aids with one omnidirectional microphone and a hearing aid with a two-microphone configuration (enabling an omnidirectional as well as a directional mode). Signal-to-noise ratio (SNR) measurements were carried out for three different types of background noise (speech-weighted noise, traffic noise and restaurant noise) and two kinds of speech material (bisyllabic word lists and sentences). The average SNR improvement of the directional microphone configuration relative to the omnidirectional one was 3.4 dB for noise presented from 90 degrees azimuth. This improvement was independent of the specific type of noise and speech material, indicating that one speech-in-noise condition may yield enough relevant information in the evaluation of directional microphones and speech understanding in noise.  相似文献   

17.
Recent research suggests that omnidirectional hearing aids are relatively ineffective at improving speech understanding in everyday conversational speech settings when the background noise contains both energetic and informational masking components. Energetic masking refers to situations where the peripheral (or neural) activity of the target is less than that of the masker, thus making the target inaudible. In contrast, informational masking effects, in this paper, refer to additional masking effects that are not energetic in nature. The current study evaluated the benefits of directional technology in the presence of background noises that contained both energetic and informational masking components. Aided speech recognition (in both omnidirectional and directional modes) was assessed in the presence of three types of maskers (forward and reversed speech and speech-modulated noise) that varied in the amount of informational masking they were expected to produce. Study results showed significant directional benefit in all conditions. This finding suggests that in everyday conversational speech environments, directional technology is equally efficacious regardless of the magnitude of informational masking present in the background noise. In addition, study findings suggest that the semantic information present in the masking speech may play only a limited role in contributing to informational masking in everyday environments.  相似文献   

18.
PURPOSE: To examine speech recognition performance and subjective ratings for directional and omnidirectional microphone modes across a variety of simulated classroom environments. METHOD: Speech recognition was measured in a group of 26 children age 10-17 years in up to 8 listening environments. RESULTS: Significant directional benefit was found when the sound source(s) of interest was in front, and directional decrement was measured when the sound source of interest was behind the participants. Of considerable interest is that a directional decrement was observed in the absence of directional benefit when sources of interest were both in front of and behind the participants. In addition, limiting directional processing to the low frequencies eliminated both the directional deficit and the directional advantage. CONCLUSIONS: Although these data support the use of directional hearing aids in some noisy school environments, they also suggest that use of the directional mode should be limited to situations in which all talkers of interest are located in the front hemisphere. These results highlight the importance of appropriate switching between microphone modes in the school-age population.  相似文献   

19.

Objectives

The aims of this study were to find and compare the effect of directional (DIR) processing of two different hearing aids via both subjective and objective methods, to determine the association between the results of the subjective and objective evaluations, and to find out individual predictive factors influencing the DIR benefit.

Methods

Twenty-six hearing aid users fitted unilaterally with each two different experimental hearing aid performed modified Korean Hearing in Noise Test (K-HINT) in three DIR conditions; omnidirectional (OMNI) mode, OMNI plus noise reduction feature, fixed DIR mode. In order to determine benefits from DIR benefit within a hearing aid and compare performance of the DIR processing between hearing aids, a subjective questionnaire was administrated on speech quality (SQ) and discomfort in noise (DN) domain. Correlation analysis of factors influencing DIR benefit was accomplished.

Results

Benefits from switching OMNI mode to DIR mode within both hearing aids in K-HINT were about 2.8 (standard deviation, 3.5) and 2.1 dB SNR (signal to ratio; SD, 2.5), but significant difference in K-HINT results between OMNI and OMNI plus noise reduction algorithm was not shown. The subjective evaluation resulted in the better SQ and DN scores in DIR mode than those in OMNI mode. However, the difference of scores on both SQ and DN between the two hearing aids with DIR mode was not statistically significant. Any individual factors did not significantly affect subjective and objective DIR benefits.

Conclusion

DIR benefit was found not only in the objective measurement performed in the laboratory but also in the subjective questionnaires, but the subjective results was failed to have significant correlation with the DIR benefit obtained in the K-HINT. Factors influencing individual variation in perceptual DIR benefit were still hard to explain.  相似文献   

20.
The performance of 40 hearing-impaired adults with the GN ReSound digital BZ5 hearing instrument was compared with performance with linear hearing aids with input compression limiting (AGC-I) or two-channel analog wide dynamic range compression (WDRC) instruments. The BZ5 was evaluated with an omnidirectional microphone, dual-microphone directionality, and a noise reduction circuit in combination with dual-microphone directionality. Participants were experienced hearing aid users who were wearing linear AGC-I or analog WDRC instruments at the time of enrolment. Performance was assessed using the Connected Speech Test (CST) presented at several presentation levels and under various conditions of signal degradation and by the Profile of Hearing Aid Benefit (PHAB). Subjective ratings of speech understanding, listening comfort, and sound quality/naturalness were also obtained using 11-point interval scales. Small performance advantages were observed for WDRC over linear AGC-I, although WDRC did not have to be implemented digitally for these performance advantages to be realized. Substantial performance advantages for the dual microphones over the omnidirectional microphone were observed in the CST results in noise, but participants generally did not perceive these large advantages in everyday listening. The noise reduction circuit provided improved listening comfort but little change in speech understanding.  相似文献   