1.
Md Quamar Azam AA Iraqi MKA Sherwani Amir Bin Sabir M Abbas Naiyer Asif 《Indian Journal of Orthopaedics》2009,43(1):62-66
Background:
Neglected femoral neck fracture in adults still poses a formidable challenge. Existing treatment options varies from osteotomy (with or without graft) to osteosynthesis using various implants and grafting techniques (muscle pedicle, vascularized, and nonvascularized fibula). The aim of this study was to assess outcome of nonvascularized fibular strut graft and cancellous screw fixation in neglected femoral neck fractures in the younger age group.Materials and Methods:
Medical records of 32 patients of neglected femoral neck fracture, in the age group of 22-45 years (mean 37.8 years), operated between May 1994 to December 2001, were retrospectively reviewed. After the application of inclusion and exclusion criteria, 28 patients having three years minimum follow-up (mean 4.6 years) were included. Delay between injury and operation varied from four weeks to 42 weeks (mean 16.4 weeks). Closed reduction was achieved in 17 patients; open reduction through Watson-Jones anterolateral approach was performed in the remaining 15 patients in whom closed reduction failed. The fracture was transfixed with three parallel guide wires. Appropriate sized cannulated lag screw (7 mm) was then inserted in two of the wires. Selection of the third guide wire for fibula depended on the space available in both anteroposterior and lateral view.Results:
Satisfactory bony union was obtained in 25 patients, of whom in four cases, the union occurred in 10-20° (mean 15°) of varus. Nonunion occurred in three patients (9.37%), and aseptic necrosis occurred in another six patients (18.75%). Of the 25 patients where union was achieved, five patients showed excellent results; 14 good and six had poor functional result, as evaluated using modified Anglen criteria.Conclusion:
Nonvascularized fibular strut graft along with cancellous screws provides a dependable and technically less-demanding alternative procedure for neglected femoral neck fractures in young adults. Fibula being cortical provides mechanical strength besides stimulating the union and getting incorporated as biological graft. 相似文献2.
Sameer Jain Benjamin A. Haughton Christopher Brew 《Journal of orthopaedics and traumatology》2014,15(4):245-254
Background
Ankle fractures are extremely common and represent nearly one quarter of all lower-limb fractures. In the majority of patients, fractures involve the distal fibula. The current standard in treating unstable fractures is through open reduction and internal fixation (ORIF) with plates and screws. Due to concerns with potentially devastating wound complications, minimally invasive strategies such as intramedullary fixation have been introduced. This systematic review was performed to evaluate the clinical and functional outcomes of intramedullary fixation of distal fibular fractures using either compression screws or nails.Materials and methods
Numerous databases (MEDLINE, PubMed, Embase, Google Scholar) were searched, 17 studies consisting of 1,008 patients with distal fibular fractures treated with intramedullary fixation were found.Results
Mean rate of union was 98.5 %, with functional outcome reported as being good or excellent in up to 91.3 % of patients. Regarding unlocked intramedullary nailing, the mean rate of union was 100 %, with up to 92 % of patients reporting good or excellent functional outcomes. Considering locked intramedullary nailing, the mean rate of union was 98 %, with the majority of patients reporting good or excellent functional outcomes. The mean complication rate across studies was 10.3 %, with issues such as implant-related problems requiring metalwork removal, fibular shortening and metalwork failure predominating.Conclusion
Overall, intramedullary fixation of unstable distal fibular fractures can give excellent results that are comparable with modern plating techniques. However, as yet, there is unconvincing evidence that it is superior to standard techniques with regards to clinical and functional outcome.Level of evidence
Level IV evidence. 相似文献3.
Marc Tompkins David J. Paller Douglas C. Moore Joseph J. Crisco Richard M. Terek 《Clinical orthopaedics and related research》2013,471(3):1039-1044
Background
Durability of plate fixation is important in delayed union. Although locking plates result in stronger constructs, it is not known if locking affects the fatigue life of a plate. Two locking screws on either side of the nonunion could decrease working length and increase strain in the plate. However, the reinforcing effect of the locking head on the plate may compensate, so that it is unclear whether locking reduces fatigue life.Questions/purposes
We determined whether locking screws, compression screws, and locking buttons reduce or increase the fatigue life of a plate.Methods
We tested fatigue life of four constructs using an eight-hole locking plate in a segmental defect model: (1) all locking screws (Locked; n = 5); (2) all compression screws (Unlocked; n = 5); (3) six compression screws with two locking buttons in the central holes (Button; n = 6); and (4) six compression screws with two open central holes (Open; n = 6).Results
The Button group had the longest fatigue life (1.3 million cycles). There was no difference between the Locked and Unlocked groups. All of the constructs failed by fracture of the plates through a screw hole adjacent to the defect.Conclusions
Locking screws did not improve fatigue life, however a locking button increased the fatigue life of a locking plate in a segmental bone defect model.Clinical Relevance
Locking buttons in holes adjacent to a defect may improve durability, which is important when delayed union is a possibility. 相似文献4.
5.
Indranil V. Kushare Dino Colo Hooman Bakhshi John P. Dormans 《Journal of children's orthopaedics》2014,8(6):505-511
Purpose
The management of proximal femoral deformity in fibrous dysplasia (FD) is a challenge to the orthopaedic surgeon. The purpose of this study was to analyze the various presentations of FD of proximal femur and the results of the various treatment modalities for the same.Methods
This is a retrospective cohort study of 23 patients (24 femora) with FD who underwent surgery for the proximal femur. The study sample included 14 males, nine females. Ten patients had a monostotic disease, eight patients had polyostotic disease, and five patients had McCune-Albright syndrome.Results
Group 1: shepherd crook deformity—included five patients who underwent femoral neck osteotomy. Four patients had intramedullary (IM) nailing with neck cross-pinning and all patients showed union. One patient was stabilized with external fixation, which failed. Group 2: nine patients (ten femora) presented with frank pathological fracture. Nine underwent fixation with IM nailing, one with locking plate and screws. Three patients had to undergo more than one procedure and all fractures showed good union. Group 3: nine patients who presented with bone cyst and pain. All patients underwent biopsy; four of them had curettage with bone graft.Conclusion
Shepherd crook deformity can be treated by a well-planned osteotomy and fixation with intramedullary implants with neck cross-pinning. Frank pathological fractures fixation with an intramedullary nail has excellent results even if not accompanied by resolution of the fibrodysplastic lesion. More than one procedure may be required. External fixation is not an optimal choice for fixation of femoral osteotomies in FD. 相似文献6.
Jairamchander Pingle 《Indian Journal of Orthopaedics》2014,48(1):25-29
Background:
Nonunion and avascular necrosis (AVN) of the femoral head remains one of the major complications following femoral neck fractures. Despite various surgical techniques and internal fixation devices, the incidence of nonunion and AVN has remained unsolved. Neglected nonunion of femoral neck fracture is common in the developing world. Treatment options include rigid internal fixation with or without bone grafting, muscle pedicle bone graft, valgus osteotomy of the proximal femur with or without bone graft, valgus osteotomy or hip arthroplasty. We conducted a retrospective analysis of cases of nonunion of femoral neck fracture treated by transfracture abduction osteotomy (TFAO).Materials and Methods:
Over a period of 35 years (1974-2008), 30 patients with nonunion of femoral neck fractures were treated with TFAO over a period of 35 years (1974-2008), All patients were less than 50 years of age. Absence of clinical and radiological signs of union after four months was considered as nonunion. Patients more than 50 years of age were excluded from the study. Union was assessed at 6 months radiologically. Limb length was measured at six months. The mean duration of femoral neck fracture was 19 months (range 4 months 10 years). Results were analyzed in terms of radiological union at six months. Average followup was five years and six months.Results:
Consistent union was noted at the followup after six months in 29 cases. One case was lost to followup after five and one-half months postoperatively. However, the fracture had united in this case at the last followup. Average shortening of the limb at six months was 1.9 cm. Average neck shaft angle was 127° (range 120-145°). Five cases went into AVN but were asymptomatic. Two cases required reoperation due to back out of Moore''s pins. These were reopened and cancellous screws were inserted in the same tracks.Conclusions:
Consistent union of nonunion femoral neck fracture was noted at the followup after six months in 29 cases. The major drawback of the procedure is immobilization of the patient in the hip spica for eight weeks. 相似文献7.
8.
PK Sundar Raj Jiju A Nuuman Amish Sunder Pattathil 《Indian Journal of Orthopaedics》2015,49(2):187-192
Background:
Femoral neck fractures are treated either by internal fixation or arthroplasty. Usually, cannulated cancellous screws are used for osteosynthesis of fracture neck of femur. The bone impregnated hip screw (BIHS) is an alternative implant, where osteosyntehsis is required in femoral neck fracture.Materials and Methods:
The BIHS is a hollow screw with thread diameter 8.3 mm, shank diameter 6.5 mm and wall thickness 2.2 mm and holes in the shaft of the screw with diameter 2 mm, placed in a staggered fashion. Biomechanical and animal experimental studies were done. Clinical study was done in two phases: Phase 1 in a group of volunteers, only with BIHS was used in a pilot study and phase 2 comparative study was done in a group with AO cannulated screws and the other group treated with BIHS.Results:
In the phase 1 study, out of 15 patients, only one patient had delayed union. In phase 2, there were 78 patients, 44 patients in BIHS showed early union, compared to the rest 34 cases of AO cannulated screws Out of 44 patients with BIHS, 41 patients had an excellent outcome, 2 had nonunions and one implant breakage was noted.Conclusions:
Bone impregnated hip screw has shown to provide early solid union since it incorporates the biomechanical principles and also increases the osteogenic potential and hence, found superior to conventional cannulated cancellous screw. 相似文献9.
Pramod Saini Abhinav Aggrawal Sanjay Meena Vivek Trikha Samarth Mittal 《Journal of Clinical Orthopaedics and Trauma》2014,5(4):252-256
Aim
To describe here a technique of miniarthrotomy assisted percutaneous screw insertion for displaced Herscovici type B and C medial malleolar fractures.Method
Incision was made centred over the superomedial angle of the ankle mortise, about half a cm medial to tibialis anterior. Arthrotomy was done and reduction obtained. Percuntaneously, two 4 mm cancellous cannulated screws were inserted through medial malleolus.Results and conclusion
This approach allows direct visualization of reduction, removal of entrapped soft tissue and preservation of saphenous vein and nerve. 相似文献10.
Pankaj Kumar Mishra Anuj Gupta Suresh Chandra Gaur 《Indian Journal of Orthopaedics》2014,48(5):470-475
Background:
Femoral neck fractures are notorious for complications like avascular necrosis and nonunion. In developing countries, various factors such as illiteracy, low socioeconomic status, ignorance are responsible for the delay in surgery. Neglected fracture neck femur always poses a formidable challenge. The purpose of this study was to evaluate the results of triple muscle pedicle bone grafting using sartorius, tensor fasciae latae and part of gluteus medius in neglected femoral neck fracture.Materials and Methods:
This is a retrospective study with medical record of 50 patients, who were operated by open reduction, internal fixation along with muscle pedicle bone grafting by the anterior approach. After open reduction, two to three cancellous screws (6.5 mm) were used for internal fixation in all cases. A bony chunk of the whole anterior superior iliac spine of 1 cm thickness, 1 cm width and 4.5 cm length, taken from the iliac crest comprised of muscle pedicle of sartorius, tensor fascia latae and part of gluteus medius. Then the graft with all three muscles mobilized and put in the trough made over the anterior or anterosuperior aspect of the femoral head. The graft was fixed with one or two 4.5 mm self-tapping cortical screw in anterior to posterior direction.Results:
14 patients were lost to followup. The results were based on 36 patients. We observed that in our series, there was union in 34, out of 36 (94.4%) patients. All patients were within the age group of 15-51 years (average 38 years) with displaced neglected femoral neck fracture of ≥30 days. Mean time taken for full clinicoradiological union was 14 weeks (range-10-24 weeks).Conclusion:
Triple muscle pedicle bone grafting gives satisfactory results for neglected femoral neck fracture in physiologically active patients. 相似文献11.
Nishikant Kumar Himanshu Kataria Chandrashekhar Yadav Bharath S. Gadagoli Rishi Raj 《Journal of Clinical Orthopaedics and Trauma》2014,5(3):137-145
Background
Stable trochanteric femur fractures can be treated successfully with conventional implants such as sliding hip screw, cephalomedullary nails, angular blade plates. However comminuted and unstable inter or subtrochanteric fractures with or without osteoporosis are challenging & prone to complications. The PF-LCP is a new implant that allows angular stability by creating fixed angle block for treatment of complex, comminuted proximal femoral fractures.Method
We reviewed 30 patients with unstable inter or subtrochanteric fractures, which were stabilized with PF-LCP. Mean age of patient was 65 years, and average operative time was 80 min. Patients were followed up for a period of 3 years (June 2010–June 2013). Patients were examined regularly at 3 weekly interval for signs of union (radiological & clinical), varus collapse (neck-shaft angle), limb shortening, and hardware failure.Result
All patients showed signs of union at an average of 9 weeks (8–10 weeks), with minimum varus collapse (<10°), & no limb shortening and hardware failure. Results were analysed using IOWA (Larson) hip scoring. Average IOWA hip score was 77.5.Conclusion
PF-LCP represents a feasible alternative for treatment of unstable inter- or subtrochanteric fractures. 相似文献12.
13.
Jan Vanderstappen Johan Lammens Pieter Berger Armand Laumen 《Journal of children's orthopaedics》2015,9(4):319-324
Purpose
Most studies on congenital pseudarthrosis of the tibia (CPT) report on the short-term union rate and refracture rate but do not take into account the long-term outcome. This review includes patients treated with an Ilizarov bone transport, who all reached skeletal maturity. It describes long-term results and highlights any prognostic factors that could predict the final outcome.Methods
The records of patients with CPT treated with an Ilizarov bone transport in our institution were retrospectively evaluated.Results
A total of 12 consecutive patients were studied. The mean follow-up was 24.5 years (range 6–39 years). Primary consolidation was seen in ten patients (83 %). Half of these patients had a refracture. At final follow-up, eight patients experienced union and four remained un-united, of whom one had an amputation.Conclusions
The present data confirm a good primary healing rate. However, tibial union at final follow-up was only seen in 67 %, indicating that refracture is the main issue. United bone is often of inferior biological and mechanical quality, so lifetime protection with intramedullary devices, braces or a combination of both is recommended. 相似文献14.
MD Wijeratna J McRoberts MJ Porteous 《Annals of the Royal College of Surgeons of England》2015,97(4):283-286
Introduction
We investigated the financial and human costs of postoperative infection for intracapsular fracture of the femoral neck at a district general hospital in the UK.Methods
Data on postoperative infections after surgical treatment for intracapsular fracture of the femoral neck were collected prospectively from June 2005 to April 2009. Infected patients were pairwise-matched (1:2 ratio) with a non-infected group of patients from a database on hip fractures. Costs of additional surgery, duration of hospital stay, and opportunity costs were calculated using Primary Care Trust (PCT) tariffs and PCT-specific data.Results
A total of 525 patients were treated with total hip replacement (n=110) or hip hemiarthroplasty (n=415). Seventeen patients (3.2%) were identified as having a surgical-site infection. Eight (1.5%) deep infections and nine (1.7%) superficial infections were documented. Compared with the non-infected group, duration of hospital stay and the prevalence of mortality doubled. Repeat surgery and the costs associated with hospital admission were increased significantly in the infected group. Mean financial loss associated with an infected patient was £7,726, whereas an uninfected patient brought £153 of profit to the hospital. When opportunity costs were considered, an infected patient represented £24,397 of lost income.Conclusions
Postoperative infection after surgical treatment for intracapsular fracture of the femoral neck has a significant negative impact on duration of hospital stay and financial costs, and demonstrates a trend towards an increase in the prevalence of mortality. 相似文献15.
A. Clarke M. J. Flowers A. G. Davies J. Fernandes S. Jones 《Journal of children's orthopaedics》2015,9(5):411-416
Purpose
Autologous iliac crest bone grafting is an integral part of many orthopaedic surgical procedures. Several studies have documented morbidity and prolonged pain following iliac crest bone graft harvesting in adults; however, in children there is a paucity of information. The purpose of the present study was to quantify the degree of pain and morbidity associated with anterior iliac crest graft harvesting in children undergoing non-spinal orthopaedic surgery.Methods
Patients were prospectively enrolled prior to orthopaedic surgery. A patient self-reported visual analogue score was used to record pain at specified time points following surgery. In addition, the patients were reviewed at 2 and 6 weeks, 3 months and 1 year after surgery to record any complications.Results
Data was collected on 33 patients (34 graft sites). Only one patient (2.94 %) had a complication, namely an injury to the lateral femoral cutaneous nerve. This resolved 3 months after surgery. 89 % of patients had no pain at the iliac crest graft harvest site 3 months after surgery. The three patients who had pain at 3 months had visual analogue scores of 1.0, 1.1 and 1.3, respectively.Conclusion
This series reveals a very low complication rate and minimal iliac crest graft harvest site pain in children undergoing non-spinal orthopaedic surgery. In addition, the pain experienced is short-lived. 相似文献16.
17.
Purpose
A late finding of some hips treated for developmental dysplasia of the hip (DDH) is a growth disturbance of the lateral proximal femoral physis, which results in caput valgum and possibly osteoarthritis. Current treatment options include complete epiphysiodesis of the proximal femoral physis or a corrective proximal femoral osteotomy. Alternatively, a transphyseal screw through the inferomedial proximal femoral physis that preserves superolateral growth might improve this deformity.Methods
This study evaluates the effect of such a transphyseal screw on both femoral and acetabular development in patients with caput valgum following open treatment of DDH. These patients were followed clinically and radiographically until skeletal maturity. Preoperative and postoperative radiographs were assessed, measuring the proximal femoral physeal orientation (PFPO), the head–shaft angle (HSA), Sharp’s angle and the center edge angle of Wiberg (CE angle).Results
Thirteen hips of 11 consecutive patients were followed prospectively. The age at the time of transphyseal screw placement was between 5 and 14 years. The mean improvement of the PFPO and HSA was 14° (p < 0.01) and 11° (p < 0.001), respectively. The mean improvement of Sharp’s angle and CE angle was 4.7° (p < 0.01) and 5.8° (p < 0.02), respectively. Five patients underwent screw revision.Conclusions
A transphyseal screw across the proximal femoral physis improved the proximal femur and acetabular geometry. 相似文献18.
Abbas Norouzi Javidan Hadis Sabour Sahar Latifi Farzad Shidfar Mohammad Reza Vafa Ramin Heshmat Hasan Emami Razavi Bagher Larijani Hamidreza Aghaei Meybodi 《The journal of spinal cord medicine》2014,37(6):744-750
Objectives
We described the associations between demographic and injury-related factors on bone mineral density (BMD) of the spine and the hip among adult patients with chronic spinal cord injury (SCI).Design
BMD in spinal and femoral bone sites were assessed. Multivariate analysis was performed to evaluate the relationship between anthropometric and injury-related factors with BMD. Serum level and amount of dietary intake of calcium, phosphor, and 25-hydroxy vitamin D were measured.Setting
A referral tertiary rehabilitation center in Iran.Participants
Patients with SCI who had no previous history of endocrine disorders and were not on specific medications entered the investigation. Those with non-traumatic SCI, pregnant, or with substance dependency were excluded as well.Interventions
No interventions were applied.Main study outcome measures
Dual X-ray absorptiometry was performed to estimate BMD. Body mass index was positively associated with higher femoral (P < 0.01, r = 0.56) and hip (P < 0.0001, r = 0.82) BMD only in female participants. The high prevalence of vitamin D deficiency (60%) was noticeable.Results
Older male patients revealed lower BMD only in spinal vertebrae (P < 0.02, r = −0.21). A significant higher BMD loss in lumbar vertebras in male patients with complete spinal cord lesion (P < 0.009) was detected. Spinal reduction of BMD was more severe when the level of injury was above T6 (P < 0.02).Conclusion
Along with the clarification of age, gender, post injury duration, and the other factors'' effect on the BMD in the SCI patients, here we have also shown the noticeable prevalence of the 25-hydoxy vitamin D deficiency in these patients which needs attention. 相似文献19.
Kevin Lutsky C. Edward Hoffler Nayoung Kim Jonas L. Matzon 《Hand (New York, N.Y.)》2015,10(3):489-491
Hypothesis
Volar locking plate fixation is a common treatment method for distal radius fractures. Recently, implants have been designed with an option to use locking screws in the shaft portion of the plate. While there is a high incidence of low bone mineral density in patients who sustain fragility fractures of the distal radius, the need for locking shaft screws is not well defined. Our hypothesis is that the routine use of locking screws in the shaft portion of volar plates is not required to maintain reduction or to prevent hardware failure.Methods
A retrospective review was performed in all patients over age 50 years who underwent volar plate fixation using an implant with non-locking shaft screws for a distal radius fracture during a 2-year period. Patients were permitted to perform early range of motion exercises. Radiographs were examined and measurements were obtained to assess maintenance of reduction and incidence of hardware failure. Patients were followed at least until fracture healing. Patients were excluded from analysis if locking shaft screws were utilized or if follow-up was inadequate.Results
Forty-one patients met the inclusion criteria. The average age was 62 years (range 50–79). There were 12 men and 29 women. The implant used incorporated 3.5-mm shaft screws in 26 patients and 2.4-mm shaft screws in 15 patients. All patients healed within acceptable radiographic parameters (mean volar tilt = 4.9°, mean radial inclination = 21.7°, mean radial height = 11.6 mm). There were not any instances of hardware failure.Discussion
Distal radius fractures frequently occur in patients with low bone mineral density. Non-locking, bicortically placed shaft screws provide adequate stability to allow for early range of motion without loss of reduction or hardware failure. The routine use of locking screws in the shaft portion of volar plates does not appear justified. 相似文献20.
Marija Djuric Slavisa Zagorac Petar Milovanovic Danijela Djonic Slobodan Nikolic Michael Hahn Vladimir Zivkovic Marko Bumbasirevic Michael Amling Robert Percy Marshall 《International orthopaedics》2013,37(1):21-26