 共查询到19条相似文献,搜索用时 187 毫秒
1.
目的 探讨健康者脾脏18F-脱氧葡萄糖(FDG) PET/CT显像特征,为在18F-FDG PET/CT显像中判断脾脏是否有异常病灶提供正常参考值依据.方法 选择行18F-FDG PET/CT体格检查的健康者100例.在PET图像横断面上对脾脏和肝脏分别手动勾画感兴趣区(ROI),测定标准摄取值(SUV),包括SUV最大值(SUVmax)和SUV平均值(SUVavg),同时测定肝脏和脾脏的CT值,再计算脾脏与肝脏的SUV比值及CT值比值.结果 (1)正常脾脏SUVmax和SUVavg分别为2.27、1.73,CT值为53.90 HU.(2)脾脏/肝脏SUVmax比值为0.80,脾脏/肝脏SUVavg比值为0.86,所有受检者脾脏SUV均低于肝脏.(3)脾脏/肝脏CT值比值为0.86,所有受检者脾脏CT值均低于肝脏.(4)男性组脾脏SUVmax高于女性组(P<0.05),男女组间脾脏SUVavg比较差异无统计学意义(P>0.05).(5)<60岁和≥60岁组间脾脏SUV比较差异无统计学意义(P>0.05).结论 18F-FDGPET/CT显像示正常脾脏放射性分布及密度分布均匀,18F-FDG生理性摄取程度及CT值均低于肝脏.  相似文献   

2.
目的:探讨正则化有序子集最大期望值(OSEM)(正则化OSEM)迭代算法对18F-氟代脱氧葡萄糖(18F-FDG)正电子发射断层显像/计算机断层显像(PET/CT)图像质量和标准摄取值(SUV)的影响.方法:选取医院核医学科行18F-FDG PET/CT检查的144例肿瘤复查患者的PET图像,图像重建采用OSEM迭代法...  相似文献   

3.
目的评价18F-FDG PET-CT在甲状腺肿瘤原发灶的诊断价值。方法 45例经术前B超检查,共50个病灶怀疑甲状腺恶性肿瘤纳入研究,术前行18F-FDG PET/CT检查评价良恶性,术后病理诊断作为"金标准",对比、评价18F-FDG PET/CT的诊断价值及探讨SUVmax的最佳诊断界值。结果 50个病灶,病理诊断26例为恶性肿瘤,24例为良性肿物。18F-FDG PET/CT诊断的敏感度为88.5%,特异度为79.2%。恶性组SUVmax高于良性组。SUVmax最佳诊断界值为1.810。结论对于B超怀疑的甲状腺恶性肿瘤,18F-FDG PET/CT有很好的诊断价值,寻找合适的SUVmax界值有助于提高诊断准确性。  相似文献   

4.
目的:研究SPECT平面显像中不同矩阵与距离下图像质量影响。方法:依据标准制作甲状腺模型与双点源模型,对不同距离、矩阵采集数据做分析。结果:对相同距离下128×128、256×256、512×512矩阵60s采集计数做两两比较q检验,30mm、50mm、100mm、150mm、200mm处的q值分别为0.80、0.82、0.76;0.79、0.83、0.85;0.80、0.82、0.83;0.82、0.83、0.85;0.83、0.85、0.89,以上均P<0.01,尚不能认为相同距离时不同矩阵的采集计数有差别。在空气介质中一定距离下矩阵128×128、256×256、512×512的径向半高宽(mm)为12.53±2.26、10.87±0.80、7.06±1.80。高矩阵、点源与探头距离近的图像可调节的宽容度大。结论:在相同距离、相同时间下不同采集矩阵的总采集计数没有差别。随着矩阵的每次上升,灵敏度不会下降,系统分辨率略有上升。平面显现中通过简单的函数滤波,可使图像表现的更完美。  相似文献   

5.
目的:基于成年男性仿真胸部体模(PH-N1)CT扫描,探究不同管电压结合人工智能(AI)重建(CI)算法对胸部体模CT扫描图像质量和辐射剂量的影响。方法:采用512层超高端CT分为4种管电压对体模进行扫描,分别为70 kV、80 kV、100 kV和120 kV,对不同管电压的CT扫描图像采用10%、30%、50%、70%和90%CI算法重建1 mm薄层图像,比较4组扫描的容积剂量指数(CTDIvol)和剂量-长度乘积(DLP)。测量图像主动脉、腹壁脂肪及竖棘肌的CT值、标准偏差(SD)值,由两名5年以上工作经验的高年资诊断医师独立双盲的对图像质量进行5分制评估,并行Kappa一致性检验。采用单因素方差分析比较图像目标组织的CT值、SD值差异。采用Friedman秩和检验比较组间主观图像质量的差异。结果:4种不同管电压的CTDIvol和DLP比较,差异有统计学意义(F=1855.617、3996.118,P<0.05)。在70 kV管电压下,10%、30%、50%、70%和90%CI算法重建的主动脉、腹壁脂肪及竖棘肌的CT值比较,差异均无统计学意义(P>0.05),而SD值...  相似文献   

6.
目的探究18氟-2脱氧-D-葡萄糖(18F-FDG)正电子发射断层显像/X线计算机体层成像仪(PET/CT)在宫颈癌分期及淋巴结转移评估中的应用价值。方法回顾性分析2017年5月至2018年5月在金华市人民医院接受18F-FDG PET/CT检查的53例宫颈癌患者的影像学资料,以手术病理结果为金标准评估18F-FDG PET/CT对宫颈癌分期及淋巴结转移的诊断价值。结果 18F-FDG PET/CT诊断宫颈癌原发病灶的SUV max曲线下面积(AUC)为0.78(Z=4.50,P<0.05),诊断界值为4.21,对应的敏感度、特异度、准确度为77.36%、88.68%、83.02%;18F-FDG PET/CT分期诊断准确率86.79%略高于MRI分期诊断准确率79.25%,但差异无统计学意义(χ~2=1.07,P>0.05);18F-FDG PET/CT诊断宫颈癌盆腔淋巴结转移SUV max曲线下面积(AUC)为0.82(Z=6.00,P<0.05),诊断界值为3.36,对应的敏感度、特异度、准确度为82.35%、77.78%、79.25%。结论 18F-FDG PET/CT显像对宫颈癌分期及淋巴结转移评估具重要临床意义,可正确指导临床诊疗方案的制定与预后评估。  相似文献   

7.
目的:研究飞行时间(TOF)技术对PET/CT图像质量的影响,并通过蒙特卡罗方法模拟验证TOF技术的优越性。方法:使用拥有TOF技术的飞利浦Gemini TF型号PET/CT,通过模体扫描分析不同采集计数下TOF重建和non-TOF重建图像的对比度变化。使用蒙特卡罗方法建立PET/CT仪器几何模型和物理过程,模拟PET/CT活度-计数特性曲线和不同时间分辨率下的信噪比(SNR)。结果:从模体实验所获得的图像比较中可以直观地看到,与non-TOF图像比较,TOF图像更加清晰,其均匀性、病灶轮廓区分度、鉴别小病灶的能力和病灶与本底的对比度等均明显优于non-TOF重建图像,特别是在低计数采集条件下,对比度可提高10%。蒙卡模拟PET的计数特性表明,符合计数和SNR随着活度的增大而增大,但在高活度区域随机符合计数过多并且SNR增长缓慢。SNR和时间分辨率成反比关系,时间分辨率越小,SNR越高,520 ps时间分辨率的SNR相较1 000 ps时间分辨率的SNR提高约50%。结论:使用TOF技术的PET/CT可以明显提高图像质量,减少扫描时间和注射用药剂量。  相似文献   

8.
目的分析不同扫描参数对图像质量及密度分辨力的影响,研究螺旋CT在最佳密度分辨力时的扫描参数。结果改变扫描参数,图像质量及图像密度分辨力均有改变,并呈现一定规律的变化。对于10mm层厚、400mm重建显示视野,使用512×512重建矩阵,平滑重建算法时,最佳密度分辨力时的扫描参数为375mAs@100kV、300mAs@120kV3、00mAs@140kV。结论不同群体的肝脏病人平扫的临床最佳扫描参数:对于10mm层厚、400mm重建显示视野,使用512×512重建矩阵,平滑重建算法时,375mAs@100kV适合于偏瘦体型(体重55公斤以下)的成人患者,300mAs@120kV适合中型身材(体重55公斤-70公斤)的成人患者,300mAs@140kV适合偏胖体型(体重70公斤以上)的成人患者。  相似文献   

9.
目的 比较不同采集时间下分块顺序正则化期望最大化(BSREM)算法较有序子集期望最大化(OSEM)算法对18F-FDG PET图像质量的影响,探讨其优化采集时间的可行性。方法 模体实验采用NEMA/IEC PET 模体,临床研究中连续收集2020年3—9月因肺结节行18F-FDG PET-CT检查患者61例(66个高摄取肺结节)。模体实验和临床研究均以不同采集时间按BSREM和OSEM算法重建PET图像。比较上述序列的变异系数(CV)、信噪比(SNR)、对比噪声比(CNR)、活度测量值(模体实验为摄取值UV;临床研究为标准摄取值SUV)差异。结果 模体实验显示120 s BSREM序列图像质量优于120 s OSEM序列,75 s BSREM序列与120 s OSEM序列相仿。临床研究显示120 s BSREM序列图像质量优于120 s OSEM序列,且75 s BSREM序列较120 s OSEM序列略优。结论 PET模体实验和肺部高摄取结节临床研究中,应用BSREM算法较OSEM算法明显改善图像质量,75 s BSREM序列图像质量较120 s OSEM序列略优。  相似文献   

10.
目的探讨18F-FDG PET/CT显像在诊断食管癌淋巴结转移与病理对照研究价值。方法回顾分析我院食管癌淋巴结转移患者,术前行18F-FDG PET/CT显像,对转移淋巴结的最大标准摄取值(SUVmax)分析,并与病理结果对照。结果 PET/CT显像SUVmax界值为2.5、5诊断食管癌淋巴结转移的灵敏度、特异性、准确性分别为:69.48%、92.71%、83.33%和87.66%、94.51%、93.26%。结论 PET/CT显像诊断食管癌转移淋巴结有较高准确性,选择SUVmax界值为5对诊断准确性更高。  相似文献   

11.
To assess the effect of lesion motion and respiration rate on Standardised Uptake Value (SUV) and the ability of 4D PET to restore any loss in SUV and distortion of lesion volume on two PET/CT systems. A Perspex phantom with four cylindrical reservoirs filled with 18F-FDG was used in this study. The cylinders measured 5, 10, 15, and 20 mm in diameter. A GE Discovery STE8 (GE Medical Systems Milwaukee, WI) and a Siemens Biograph 64/40 (Siemens Medical Solutions, Erlangen, Germany) scanner was used to acquire a stationary un-gated PET scan of the phantom. Multiple 10 min list mode 4D PET scans were acquired using the Varian RPM on the GE camera and the Anzai Gating system on the Siemens camera. The phantom was scanned at five different respiratory rates and motion amplitudes in a sinusoidal fashion, 15 RPM/1 cm, 15 RPM/2 cm, 15 RPM/4 cm, 30 RPM/2 cm and 7.5 RPM/2 cm (RPM-respirations per minute). Each scan was reconstructed into ten bins and as an un-gated static image. The SUVmax, SUVmean and volume were measured for all four reservoirs using Siemens TrueD analysis software. With increasing lesion movement the SUVmax and SUVmean decreased and the volume increased with the SUVmax in the smallest lesion underestimated by up to a factor of four. The SUVmax, SUVmean and volume were mostly recovered using 4D imaging regardless of amount of lesion displacement. The larger lesions showed better count recovery and volume correction than the smaller lesions. The respiratory rate had no effect of SUV or volume. Un-gated imaging of moving lesions decreases apparent SUV in small lesions significantly and overestimates volumes. 4D PET scanning recovers most of the apparent loss in SUV and distortion of volumes.  相似文献   

12.
This study aimed to quantify the amount of change in Standardised Uptake Values (SUVs) of PET/CT images by simulating the set-up as closely as possible to the actual patient scanning. The experiments were conducted using an anthropomorphic phantom, which contained an amount of radioactivity in the form of Fluorodeoxyglucose (FDG) in a primary plastic test tube and one litre saline bags, including the insertion of bony structures and another two test tubes containing different concentrations of iodine contrast media. Standard scanning protocols were employed for the PET/CT image acquisition. The highest absolute differences in the SUVmax and SUVmean values of the saline bags were found to be about 0.2 and 0.4, respectively. The primary test tube showed the largest change of 1.5 in both SUVs; SUV max and SUVmean. However, none of these changes were found to be statistically significant. The clinical literature also contains no evidence to suggest that the changes of this magnitude would change the final diagnosis. Based on these preliminary data, we propose that iodine contrast media can be used during the CT scan of PET/CT imaging, without significantly affecting the diagnostic quality of this integrated imaging modality.  相似文献   

13.
目的 探讨PET/CT成像条件(采集时间、床位重叠、重建矩阵、迭代次数、滤波核、衰减校正)对图像空间分辨率的影响。方法 使用GE Discovery Elite型和GE Discovery ST-16型2种PET/CT设备分别对椭圆柱分辨率模型进行1个和2个床位扫描(List mode模式,采集时间为6 min);使用临床常用重建条件(Elite型:VPFX-S算法;ST-16型:VUE Point HD算法)分别按1~6 min/床、不同迭代次数2~10次、滤波核2.0~10.0 mm(Elite型)、不同的重建矩阵以及是否进行衰减校正对图像进行重建;用线源扩展函数的半高宽(FWHM)表示PET重建图像的空间分辨率。结果 在临床采集条件下,当采集时间为1 min、2 min、3 min、4 min、5 min、6 min时,中心位置图像空间分辨率FWHMElite分别为(4.06±0.08)mm、(4.05±0.20)mm、(4.01±0.01)mm、(4.05±0.07)mm、(4.05±0.03)mm、(4.08±0.06)mm;FWHMST-16分别为(5.76±0.12)mm...  相似文献   

14.
目的:探讨18F-FDG PET/CT在胆管癌术前诊断和术后疗效评估中的应用价值。方法:对25例胆管癌患者(术前7例,术后18例)进行18F-FDG PET/CT显像检查,测定病灶部位初次检查及延迟显像SUVmax,观察其表现及术后疗效。结果:PET/CT诊断胆管癌符合率100%,灵敏度95%,特异性90%。结论:18F-FDG PET/CT对胆管癌的诊断和术后疗效评估具有重要临床价值。  相似文献   

15.
目的:探讨患者胃肠道准备对18F-FDGPET/CT检查的影响。方法:回顾250例18F-FDGPET/CT显像结果,结合SUV值和患者病史及其它临床资料进行分析。结果:42例胃肠道准备不足的患者中,影像受胃肠道干扰的有17例;而胃肠道准备充分的208例患者中仅4例显像受胃肠道干扰。结论:正确而充分的胃肠道准备是提高18F-FDGPET/CT检查图像质量的重要因素。  相似文献   

16.
孙晓伟  梁艳  高燕  张华  陈艳霞  郭建 《职业与健康》2014,(13):1764-1766,1775
目的探讨18F-FDGPET/CT显像[(18F)氟-2-脱氧葡萄糖正电子发射体层扫描/X线计算机体层显像]与血清肿瘤标志物联合检测在尘肺合并肺癌诊断中的应用价值。方法53例肺部病灶性质待定的尘肺患者,全部行18F-FDGPET/CT显像检查,并在1周内检测血清中肿瘤标志物癌胚抗原神经元特异性烯醇化酶(CEA、NSE、CYFRA211、CA199、CA125),分析2种检查之间的差异和相互关系。结果18F-FDGPET/CT及血清中肿瘤标志物诊断肺癌的敏感性分别为100%,81%,特异性分别为53.1%,68.8%,约登指数分别为0.531,0.466。PET—CT显像联合血清中肿瘤标志物检测诊断肺癌的敏感性可达100%,特异性为53.1%,约登指数为0.531。原发灶最大标准摄取值(SUVmax)与CYFRA21—1有弱的相关性(r=0.209,P=0.042);在鳞癌患者中SUVmax与CYFRA21—1呈显著相关(r=0.551,P=0.041);在小细胞肺癌中,SUVmax与NSE显著相关(r=0.453,P=0.038)。结论PET/CT诊断尘肺合并肺癌的敏感性较肿瘤标志物高,肿瘤标志物对PET/CT诊断具有补充作用,两者联合应用对于尘肺合并肺癌的诊断具有重要的临床价值。  相似文献   

17.
目的:探讨18F-脱氧葡萄糖(FDG)PET延迟显像在原发性肺癌诊断中的价值。方法:对36例原发性肺癌患者分别进行18F-FDG PET早期头部——盆腔显像和注射后3h胸部延迟显像,测定2次显像病灶的标准摄取值(SUV),并计算18F-FDG的储留指数(RI)。结果:原发性肺癌的延迟显像SUV明显高于早期显像SUV(P<0.01);以早期显像SUV>2.5作为标准,原发性肺癌诊断的灵敏度、特异性、准确性分别为80.3%、72.7%、78.6%;以RI>20%作为标准,原发性肺癌诊断的灵敏度、特异性、准确性分别为82.8%、77.9%、80.3%;结合以上2项标准,原发性肺癌诊断灵敏度、特异性、准确性分别为90.0%、80.0%和86.7%。结论:18F-FDG PET延迟显像有助于原发性肺癌的诊断,结合应用SUV及RI2项指标可提高诊断准确率。  相似文献   

18.
目的:研究不同浓度泛影葡胺溶液在不同CT扫描条件下对PET/CT图像质量的影响。方法:向5个乳胶容器中分别注入体积分数为5%、10%、15%、20%和40%的1:7服泛影葡胺溶液,依次将其密闭置于圆柱形水模内进行PET/CT成像。利用CT扫描数据对PET图像进行衰减校正,并比较不同管电压CT扫描条件下PET图像的差异。结果:体积分数为15%、20%和40%的泛影葡胺充盈区在经CT衰减校正的PET图像上表现为高浓聚伪影.标准摄取值比本底均有不同程度的升高,而体积分数为5%、10%的泛影葡胺充盈区则无明显伪影,反映了随着泛影葡胺浓度的升高CT衰减校正伪影随之增强;对于体积分数为40%的口服泛影葡胺溶液,随着CT扫描所使用的管电压的升高.经CT衰减校正的PET图像上的伪影随之减弱.标准摄取值降低。结论:体积分数大于15%的泛影葡胺溶液在PET/CT成像中标准摄取值升高,图像表现出伪影;PET/CT成像中CT扫描所采用的管电压越高,高浓度泛影葡胺溶液产生的伪影越弱。  相似文献   

19.
目的:分析研究正电子发射计算机断层显像/计算机断层显像(PET/CT)4D门控扫描技术的实际应用意义及其具体实现方法和成像结果.方法:选取场内测试时的模体数据以及在医院就诊且进行PET/CT扫描的1例患者4D门控扫描数据,采用东软医疗PET/CT系统及AnzaiAZ-733V呼吸系统对其进行呼吸门控检查,按照一个呼吸周...  相似文献   