 共查询到20条相似文献,搜索用时 78 毫秒
1.
Custom Spectral Domain Optical Coherence Tomography (SD-OCT) provided with automatic quantification and distortion correction algorithms was used to measure anterior and posterior crystalline lens surface elevation in accommodating eyes and to evaluate relationships between anterior segment surfaces. Nine young eyes were measured at different accommodative demands. Anterior and posterior lens radii of curvature decreased at a rate of 0.78 ± 0.18 and 0.13 ± 0.07 mm/D, anterior chamber depth decreased at 0.04 ± 0.01 mm/D and lens thickness increased at 0.04 ± 0.01 mm/D with accommodation. Three-dimensional surface elevations were estimated by subtracting best fitting spheres. In the relaxed state, the spherical term accounted for most of the surface irregularity in the anterior lens (47%) and astigmatism (70%) in the posterior lens. However, in accommodated lenses astigmatism was the predominant surface irregularity (90%) in the anterior lens. The RMS of high-order irregularities of the posterior lens surface was statistically significantly higher than that of the anterior lens surface (x2.02, p<0.0001). There was significant negative correlation in vertical coma (Z3−1) and oblique trefoil (Z3−3) between lens surfaces. The astigmatic angle showed high degree of alignment between corneal surfaces, moderate between corneal and anterior lens surface (~27 deg), but differed by ~80 deg between the anterior and posterior lens surfaces (including relative anterior/posterior lens astigmatic angle shifts (10-20 deg).OCIS codes: (110.4500) Optical coherence tomography, (120.6650) Surface measurements, figure, (110.6880) Three-dimensional image acquisition, (100.2960) Image analysis, (330.7327) Visual optics, ophthalmic instrumentation, (330.7322) Visual optics, accommodation, (330.7323) Visual optics, aging changes  相似文献   

2.
Optical side-effects of fs-laser treatment in refractive surgery are investigated by means of a model eye. We show that rainbow glare is the predominant perturbation, which can be avoided by randomly distributing laser spots within the lens. For corneal applications such as fs-LASIK, even a regular grid with spot-to-spot distances of ~3 µm is sufficient to minimize rainbow glare perception. Contrast sensitivity is affected, when the lens is treated with large 3D-patterns.OCIS codes: (320.2250) Femtosecond phenomena, (330.7335) Visual optics, refractive surgery, (330.1720) Color vision, (330.4460) Ophthalmic optics and devices  相似文献   

3.
Population studies indicate that astigmatism decreases from the corneal center toward the periphery. A standard toric intraocular lens (IOL) with a constant cylinder power cannot correct uniformly across this gradient. We built an astigmatic eye model based on corneal topography data. A progressive-toric lens with gradually decreasing cylinder power was compared with an identically designed lens but featuring conventional astigmatism correction. Residual astigmatism did not differ significantly (P=0.06) at 3 mm, and the Strehl ratio was identical for both lenses (0.51 ±0.15, P=0.88). At 5 mm, the progressive IOL yielded significantly lower residual astigmatism by 0.10 D (P<0.001). The Strehl ratio was 0.30 ±0.08 with the progressive and 0.29 ±0.08 with the standard lens (P<0.001). At 3 mm, the optical performance was comparable for both IOLs. However, at 5 mm, the progressive-toric was more effective in correcting astigmatism, and it yielded reduced residual astigmatism compared to a standard toric lens.  相似文献   

4.
Remote focusing is widely used in 3D two-photon microscopy and 3D photostimulation because it enables fast axial scanning without moving the objective lens or specimen. However, due to the design constraints of microscope optics, remote focus units are often located in non-telecentric positions in the optical path, leading to significant depth-dependent 3D field distortions in the imaging volume. To address this limitation, we characterized 3D field distortions arising from non-telecentric remote focusing and present a method for distortion precompensation. We demonstrate its applicability for a 3D two-photon microscope that uses an acousto-optic lens (AOL) for remote focusing and scanning. We show that the distortion precompensation method improves the pointing precision of the AOL microscope to < 0.5 µm throughout the 400 × 400 × 400 µm imaging volume.  相似文献   

5.
We present and test a methodology for generating simultaneous vision with a deformable mirror that changed shape at 50 Hz between two vergences: 0 D (far vision) and −2.5 D (near vision). Different bifocal designs, including toric and combinations of spherical aberration, were simulated and assessed objectively. We found that typical corneal aberrations of a 60-year-old subject changes the shape of objective through-focus curves of a perfect bifocal lens. This methodology can be used to investigate subjective visual performance for different multifocal contact or intraocular lens designs.OCIS codes: (330.7335) Visual optics, refractive surgery; (110.3000) Image quality assessment; (220.1010) Aberrations (global); (220.1080) Active or adaptive optics; (330.7327) Visual optics, ophthalmic instrumentation  相似文献   

6.
We describe the first handheld, swept source optical coherence tomography (SSOCT) system capable of imaging both the anterior and posterior segments of the eye in rapid succession. A single 2D microelectromechanical systems (MEMS) scanner was utilized for both imaging modes, and the optical paths for each imaging mode were optimized for their respective application using a combination of commercial and custom optics. The system has a working distance of 26.1 mm and a measured axial resolution of 8 μm (in air). In posterior segment mode, the design has a lateral resolution of 9 μm, 7.4 mm imaging depth range (in air), 4.9 mm 6dB fall-off range (in air), and peak sensitivity of 103 dB over a 22° field of view (FOV). In anterior segment mode, the design has a lateral resolution of 24 μm, imaging depth range of 7.4 mm (in air), 6dB fall-off range of 4.5 mm (in air), depth-of-focus of 3.6 mm, and a peak sensitivity of 99 dB over a 17.5 mm FOV. In addition, the probe includes a wide-field iris imaging system to simplify alignment. A fold mirror assembly actuated by a bi-stable rotary solenoid was used to switch between anterior and posterior segment imaging modes, and a miniature motorized translation stage was used to adjust the objective lens position to correct for patient refraction between −12.6 and + 9.9 D. The entire probe weighs less than 630 g with a form factor of 20.3 x 9.5 x 8.8 cm. Healthy volunteers were imaged to illustrate imaging performance.OCIS codes: (110.4500) Optical coherence tomography, (170.4460) Ophthalmic optics and devices, (080.3620) Lens system design, (170.0110) Imaging systems, (170.5755) Retina scanning, (170.4470) Ophthalmology  相似文献   

7.
En face adaptive optics scanning laser ophthalmoscope (AOSLO) images of the anterior lamina cribrosa surface (ALCS) represent a 2D projected view of a 3D laminar surface. Using spectral domain optical coherence tomography images acquired in living monkey eyes, a thin plate spline was used to model the ALCS in 3D. The 2D AOSLO images were registered and projected onto the 3D surface that was then tessellated into a triangular mesh to characterize differences in pore geometry between 2D and 3D images. Following 3D transformation of the anterior laminar surface in 11 normal eyes, mean pore area increased by 5.1 ± 2.0% with a minimal change in pore elongation (mean change = 0.0 ± 0.2%). These small changes were due to the relatively flat laminar surfaces inherent in normal eyes (mean radius of curvature = 3.0 ± 0.5 mm). The mean increase in pore area was larger following 3D transformation in 4 glaucomatous eyes (16.2 ± 6.0%) due to their more steeply curved laminar surfaces (mean radius of curvature = 1.3 ± 0.1 mm), while the change in pore elongation was comparable to that in normal eyes (−0.2 ± 2.0%). This 3D transformation and tessellation method can be used to better characterize and track 3D changes in laminar pore and surface geometries in glaucoma.OCIS codes: (000.3860) Mathematical methods in physics, (110.1080) Active or adaptive optics, (330.4460) Ophthalmic optics and devices  相似文献   

8.
Custom high-resolution high-speed anterior segment spectral domain optical coherence tomography (OCT) was used to characterize three-dimensionally (3-D) the human crystalline lens in vivo. The system was provided with custom algorithms for denoising and segmentation of the images, as well as for fan (scanning) and optical (refraction) distortion correction, to provide fully quantitative images of the anterior and posterior crystalline lens surfaces. The method was tested on an artificial eye with known surfaces geometry and on a human lens in vitro, and demonstrated on three human lenses in vivo. Not correcting for distortion overestimated the anterior lens radius by 25% and the posterior lens radius by more than 65%. In vivo lens surfaces were fitted by biconicoids and Zernike polynomials after distortion correction. The anterior lens radii of curvature ranged from 10.27 to 14.14 mm, and the posterior lens radii of curvature ranged from 6.12 to 7.54 mm. Surface asphericities ranged from −0.04 to −1.96. The lens surfaces were well fitted by quadrics (with variation smaller than 2%, for 5-mm pupils), with low amounts of high order terms. Surface lens astigmatism was significant, with the anterior lens typically showing horizontal astigmatism (Z22 ranging from −11 to −1 µm) and the posterior lens showing vertical astigmatism (Z22 ranging from 6 to 10 µm).OCIS codes: (110.4500) Optical coherence tomography, (120.6650) Surface measurements, figure, (120.4640) Optical instruments, (120.4800) Optical standards and testing, (110.6880) Three-dimensional image acquisition, (330.7327) Visual optics, ophthalmic instrumentation  相似文献   

9.
Decades of experimental and theoretical investigations have established that photoreceptors capture light based on the principles of optical waveguiding. Yet considerable uncertainty remains, even for the most basic prediction as to whether photoreceptors support more than a single waveguide mode. To test for modal behavior in human cone photoreceptors in the near infrared, we took advantage of adaptive-optics optical coherence tomography (AO-OCT, λc = 785 nm) to noninvasively image in three dimensions the reflectance profile of cones. Modal content of reflections generated at the cone inner segment and outer segment junction (IS/OS) and cone outer segment tip (COST) was examined over a range of cone diameters in 1,802 cones from 0.6° to 10° retinal eccentricity. Second moment analysis in conjunction with theoretical predictions indicate cone IS and OS have optical properties consistent of waveguides, which depend on segment diameter and refractive index. Cone IS was found to support a single mode near the fovea (≤3°) and multiple modes further away (>4°). In contrast, no evidence of multiple modes was found in the cone OSs. The IS/OS and COST reflections share a common optical aperture, are most circular near the fovea, show no orientation preference, and are temporally stable. We tested mode predictions of a conventional step-index fiber model and found that in order to fit our AO-OCT results required a lower estimate of the IS refractive index and introduction of an IS focusing/tapering effect.OCIS codes: (010.1080) Active or adaptive optics, (110.4500) Optical coherence tomography, (330.5310) Vision - photoreceptors, (330.4300) Vision system - noninvasive assessment, (330.7331) Visual optics, receptor optics  相似文献   

10.
Adaptive optics optical coherence tomography (AO-OCT) is a highly sensitive and noninvasive method for three dimensional imaging of the microscopic retina. Like all in vivo retinal imaging techniques, however, it suffers the effects of involuntary eye movements that occur even under normal fixation. In this study we investigated dynamic retinal tracking to measure and correct eye motion at KHz rates for AO-OCT imaging. A customized retina tracking module was integrated into the sample arm of the 2nd-generation Indiana AO-OCT system and images were acquired on three subjects. Analyses were developed based on temporal amplitude and spatial power spectra in conjunction with strip-wise registration to independently measure AO-OCT tracking performance. After optimization of the tracker parameters, the system was found to correct eye movements up to 100 Hz and reduce residual motion to 10 µm root mean square. Between session precision was 33 µm. Performance was limited by tracker-generated noise at high temporal frequencies.OCIS codes: (110.1080) Active or adaptive optics, (170.4500) Optical coherence tomography, (120.3890) Medical optics instrumentation, (170.0110) Imaging systems, (170.4470) Ophthalmology, (330.5310) Vision - photoreceptors  相似文献   

11.
Spectrally encoded confocal microscopy (SECM) is a form of reflectance confocal microscopy that can achieve high imaging speeds using relatively simple probe optics. Previously, the feasibility of conducting large-area SECM imaging of the esophagus in bench top setups has been demonstrated. Challenges remain, however, in translating SECM into a clinically-useable device; the tissue imaging performance should be improved, and the probe size needs to be significantly reduced so that it can fit into luminal organs of interest. In this paper, we report the development of new SECM endoscopic probe optics that addresses these challenges. A custom water-immersion aspheric singlet (NA = 0.5) was developed and used as the objective lens. The water-immersion condition was used to reduce the spherical aberrations and specular reflection from the tissue surface, which enables cellular imaging of the tissue deep below the surface. A custom collimation lens and a small-size grating were used along with the custom aspheric singlet to reduce the probe size. A dual-clad fiber was used to provide both the single- and multi- mode detection modes. The SECM probe optics was made to be 5.85 mm in diameter and 30 mm in length, which is small enough for safe and comfortable endoscopic imaging of the gastrointestinal tract. The lateral resolution was 1.8 and 2.3 µm for the single- and multi- mode detection modes, respectively, and the axial resolution 11 and 17 µm. SECM images of the swine esophageal tissue demonstrated the capability of this device to enable the visualization of characteristic cellular structural features, including basal cell nuclei and papillae, down to the imaging depth of 260 µm. These results suggest that the new SECM endoscopic probe optics will be useful for imaging large areas of the esophagus at the cellular scale in vivo.OCIS codes: (170.1790) Confocal microscopy, (170.2150) Endoscopic imaging, (170.2680) Gastrointestinal, (170.4730) Optical pathology  相似文献   

12.
Corneal imaging is important for the diagnostic and therapeutic evaluation of many eye diseases. Optical coherence tomography (OCT) is extensively used in ocular imaging due to its non-invasive and high-resolution volumetric imaging characteristics. Optical coherence microscopy (OCM) is a technical variation of OCT that can image the cornea with cellular resolution. Here, we demonstrate a blue-light OCM as a low-cost and easily reproducible system to visualize corneal cellular structures such as epithelial cells, endothelial cells, keratocytes, and collagen bundles within stromal lamellae. Our blue-light OCM system achieved an axial resolution of 12 µm in tissue over a 1.2 mm imaging depth, and a lateral resolution of 1.6 µm over a field of view of 750 µm × 750 µm.  相似文献   

13.
Cataract-induced refractive change (CIRC) is the change in refraction induced by a cataract. It can amount to several diopters (D). It alters predicted errors in refraction following cataract surgery through changes in axial length measurement. This study determined the effect of CIRC on the accuracy of intraocular lens power formula predictions of refraction in 872 eyes of 662 patients. Regression of results gave −0.030 D prediction error per 1 D of CIRC, i.e. cataract-induced myopia and hyperopia tended to yield postoperative hyperopia and myopia, respectively. Theoretical determinations with a model eye supported this result. There was significant correlation of nuclear cataract opalescence with CIRC. Although these effects are difficult to identify based on changes in refraction, if biometers were able to identify cataract density and automatically adjust axial length measurement, IOL power predictions might improve.  相似文献   

14.
[Purpose] To assess the changes in falling risk depending on the induced axis direction of astigmatism using cylindrical lenses in a static posture. [Subjects and Methods] Twenty subjects (10 males, 10 females; mean age, 23.4 ± 2.70 years) fully corrected by subjective refraction participated. To induce myopic simple astigmatism conditions, cylindrical lenses of +0.50, +1.00, +1.50, +2.00, +3.00, +4.00, and +5.00 D were used. The direction of astigmatic axes were induced under five conditions with increased cylindrical powers:, 180°, 90°, and 45° on both eyes; 180°/90° right/left eye, and 45°/135° right/left eye. Changes in the fall risk index were analyzed using the TETRAX biofeedback system. Measurements were performed for 32 seconds for each condition. [Results] The fall risk index increased significantly from C+4.00 D in 180°/90° right/left eye, C+3.00 D in 45°/135° right/left eye, and C+3.00 D in 45° on both eyes versus corrected emmetropia. Among the five axis conditions with the same cylindrical power lenses, the increase in the fall risk index was highest at 45° in both eyes. [Conclusion] Uncorrected oblique astigmatism may increase falling risk compared to with-the-rule and against-the-rule astigmatism. Clinical specialists should consider appropriate correction of astigmatism for preventing falls, especially for uncorrected oblique astigmatism.Key words: Fall risk index, Astigmatism, Axis directions  相似文献   

15.
We demonstrated the feasibility of a CMOS-based spectral domain OCT (SD-OCT) for versatile ophthalmic applications of imaging the corneal epithelium, limbus, ocular surface, contact lens, crystalline lens, retina, and full eye in vivo. The system was based on a single spectrometer and an alternating reference arm with four mirrors. A galvanometer scanner was used to switch the reference beam among the four mirrors, depending on the imaging application. An axial resolution of 7.7 μm in air, a scan depth of up to 37.7 mm in air, and a scan speed of up to 70,000 A-lines per second were achieved. The approach has the capability to provide high-resolution imaging of the corneal epithelium, contact lens, ocular surface, and tear meniscus. Using two reference mirrors, the zero delay lines were alternatively placed on the front cornea or on the back lens. The entire ocular anterior segment was imaged by registering and overlapping the two images. The full eye through the pupil was measured when the reference arm was switched among the four reference mirrors. After mounting a 60 D lens in the sample arm, this SD-OCT was used to image the retina, including the macula and optical nerve head. This system demonstrates versatility and simplicity for multi-purpose ophthalmic applications.OCIS codes: (170.4500) Optical coherence tomography, (170.3880) Medical and biological imaging, (170.4580) Optical diagnostics for medicine, (330.4460) Ophthalmic optics and devices  相似文献   

16.
Corneal collagen cross-linking (CXL) is a clinical treatment for keratoconus that structurally reinforces degenerating ocular tissue, thereby limiting disease progression. Clinical outcomes would benefit from noninvasive methods to assess tissue material properties in affected individuals. Regional variations in tissue properties were quantified before and after CXL in rabbit eyes using optical coherence elastography (OCE) imaging. Low-amplitude (<1µm) elastic waves were generated using micro air-pulse stimulation and the resulting wave amplitude and speed were measured using phase-stabilized swept-source OCE. OCE imaging following CXL treatment demonstrates increased corneal stiffness through faster elastic wave propagation speeds and lower wave amplitudes.OCIS codes: (170.0170) Medical optics and biotechnology, (110.4500) Optical coherence tomography, (170.4580) Optical diagnostics for medicine, (170.6935) Tissue characterization  相似文献   

17.
We use our previously developed adaptive optics (AO) scanning laser ophthalmoscope (SLO)/ optical coherence tomography (OCT) instrument to investigate its capability for imaging retinal vasculature. The system records SLO and OCT images simultaneously with a pixel to pixel correspondence which allows a direct comparison between those imaging modalities. Different field of views ranging from 0.8°x0.8° up to 4°x4° are supported by the instrument. In addition a dynamic focus scheme was developed for the AO-SLO/OCT system in order to maintain the high transverse resolution throughout imaging depth. The active axial eye tracking that is implemented in the OCT channel allows time resolved measurements of the retinal vasculature in the en-face imaging plane. Vessel walls and structures that we believe correspond to individual erythrocytes could be visualized with the system.OCIS codes: (170.3890) Medical optics instrumentation, (110.1080) Active or adaptive optics, (170.4470) Ophthalmology, (330.5310) Vision - photoreceptors, (110.4500) Optical coherence tomography  相似文献   

18.
Optical coherence tomography (OCT) has a tremendous global impact upon the ability to diagnose, treat, and monitor eye diseases. A miniature 25-gauge forward-imaging OCT probe with a disposable tip was developed for real-time intraoperative ocular imaging of posterior pole and peripheral structures to improve vitreoretinal surgery. The scanning range was 2 mm when the probe tip was held 3-4 mm from the tissue surface. The axial resolution was 4-6 µm and the lateral resolution was 25-35 µm. The probe was used to image cellophane tape and multiple ocular structures.OCIS codes: (170.4500) Optical coherence tomography, (120.3890) Medical optics instrumentation  相似文献   

19.
To extend our understanding of tear film dynamics for the management of dry eye disease, we propose a method to optically sense the tear film and estimate simultaneously the thicknesses of the lipid and aqueous layers. The proposed method, SDT-OCT, combines ultra-high axial resolution optical coherence tomography (OCT) and a robust estimator based on statistical decision theory (SDT) to achieve thickness measurements at the nanometer scale. Unlike conventional Fourier-domain OCT where peak detection of layers occurs in Fourier space, in SDT-OCT thickness is estimated using statistical decision theory directly on the raw spectra acquired with the OCT system. In this paper, we demonstrate in simulation that a customized OCT system tailored to ~1 µm axial point spread function (FWHM) in the corneal tissue, combined with the maximum-likelihood estimator, can estimate thicknesses of the nanometer-scale lipid and micron-scale aqueous layers of the tear film, simultaneously, with nanometer precision. This capability was validated in experiments using a physical phantom that consists of two layers of optical coatings that mimic the lipid and aqueous layers of the tear film.OCIS codes: (170.4500) Optical coherence tomography, (030.0030) Coherence and statistical optics, (110.3000) Image quality assessment, (120.0120) Instrumentation, measurement, and metrology, (120.4290) Nondestructive testing, (330.7327) Visual optics, ophthalmic instrumentation  相似文献   

20.
We have designed an intraocular telescope for the posterior chamber of the human eye of patients with age related macular degeneration. The basic design is composed of two decentered high optical power lenses ( + 66D and −66D) inducing a 3° prismatic effect to project a magnified central field of view into a healthier location off the central fovea. Aspheric surfaces were used to ensure a compromise between good optical quality and high tolerance to the final axial position of both lenses after surgery. With this particular design, the telescope affords an extended range of depth of focus, high tolerance to different axial lengths of the eye and robustness against typical values of astigmatism and higher order aberrations. The final design has been manufactured in a foldable material and is compact enough to facilitate surgical implantation. This telescope is a simple but promising intraocular visual aid for AMD patients.OCIS codes: (330.7328) Visual optics, ophthalmic appliances; (330.4460) Ophthalmic optics and devices  相似文献   