首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 156 毫秒
1.
目的:观察应用Amplatzer封堵器经导管介入治疗先天性心脏病膜周部室间隔缺损(PMVSD)的可行性、安全性和疗效。方法:采用Amplatzer封堵器治疗先天性心脏病膜部室间隔缺损20例患者,术前由经胸超声心动图确诊PMVSD,术中经左心室造影明确缺损位置、直径、在透视及超声心动图监视下经导管置入Amplatzer封堵器封堵PMVSD,术后3d、3个月、6个月及1年分别行经胸超声心动图、心电图和X线检查。评价治疗效果。结果:20例VSD病人成功置入Amplatzer封堵器,透视及超声心动图显示即刻完全堵闭。术后出现溶血和三度房室传导阻滞各1例,对症治疗后消失。分别手术后3个月、6个月、1年随访,超声心动图示封堵器位置良好,19例完全闭合,仅1例残余分流,无严重并发症。结论:经导管置入Amplatzer封堵器治疗PMVSD是一种成功率高、并发症少、疗效可靠的介入方法。  相似文献   

2.
目的 :应用国产双盘状封堵器经导管治疗膜部室间隔缺损并对其疗效进行初步评价。方法 :全组 2 0例 ,年龄8± 6 (2~ 17)岁。室间隔缺损直径为 7.2± 2 .3(2 .0~ 14 .0 ) mm。经 7F或 8F传送鞘置入双盘状封堵器 ,封堵后即刻行左心室造影 ,术后 1d及 1月行超声心动图检查观察有无残余分流及再通。结果 :全组技术成功率 10 0 % ,术后左心室造影显示 ,6例存在微量~少量残余分流 ,14例封堵完全无残余分流。术后 2 4 h、术后 1月超声心动图未见残余分流及再通。结论 :应用双盘状封堵器治疗膜部室间隔缺损是一种安全有效的介入方法 ,成功率高 ,近期疗效可靠 ,中远期疗效尚需进一步观察  相似文献   

3.
目的:探讨经胸超声心动图(TTE)在室间隔缺损(VSD)介入封堵术中的应用价值。方法:术前经胸超声心动图扫查选择适合封堵治疗的VSD患者,然后监测导管引导Amplatzer封堵器治疗VSD的全过程,在监测过程中要认真观察导管及封堵器的位置,配合封堵器的释放,观察封堵器是否已封堵好室间隔缺损处,周边有无残余分流。  相似文献   

4.
目的探讨新型Amplatzer室间隔缺损封堵器治疗膜周部室间隔缺损(PMVSD)的临床疗效。方法采用新型Amplatzer膜周部室间隔缺损封堵器,对46例PMVSD患者进行封堵治疗。对心脏多普勒超声检查符合导管封堵条件的患者术前常规进行心导管检查,测定血流动力学参数。在X线透视、食管超声心动图(TEE)的监测下建立股动静脉轨道,经右心系统释放封堵器。病人分别于术后24小时、1个月、3个月、6个月进行随访。结果46例患者中除2例因室间隔缺损膜部瘤松软未能成功置入外,其余患者均能正确置放新型Amplatzer封堵器和即刻完全封堵PM-VSD。术后24小时至6个月进行TEE复查,所有患者被完全封堵。结论新型Amplatzer封堵器治疗PMVSD是一种安全、成功率高、近期疗效可靠的介入方法。  相似文献   

5.
目的评价经食管超声心动图(TEE)在小婴儿经胸微创室间隔缺损封堵术中的应用价值。方法经胸超声心动图诊断为室间隔缺损(VSD)患儿79例,拟行微创非体外循环下封堵治疗。术前行TEE检查,明确室间隔缺损的位置、类型、大小及边缘情况。选择合适的封堵器,术中TEE引导封堵器释放,评价即刻效果。术后1周内复查超声心动图。结果6例患者术前TEE剔除,69例患者封堵成功,4例封堵失败,转体外循环行室间隔缺损修补术。术中TEE显示,64例无残余分流,5例有微量残余分流。术后1周内超声随访,均见封堵器位置良好,1例有微量残余分流。结论TEE对选择适合行封堵的VSD患者、选择合适的封堵器、引导封堵器的释放及疗效评价均具有重要的作用。  相似文献   

6.
经导管介入治疗婴幼儿大型动脉导管未闭临床疗效   总被引:2,自引:0,他引:2  
目的 探讨应用导管介入治疗直径≥5 mm婴幼儿大型动脉导管未闭(patent ductus arteriosus,PDA)的临床疗效.方法 回顾性分析60例大型PDA(直径≥5 mm)患儿的临床资料,着重分析手术方法、临床疗效和随访结果.结果 56例PDA采用Amplatzer或国产先健动脉导管封堵器,3例采用膜部室间隔缺损封堵器,1例采用肌部室间隔缺损封堵器.封堵成功率为98.3%(59/60),术后1 d超声心动图显示15%(9/60)微量至少量残余分流,术后3月超声心动图复查未见残余分流;3例采用室间隔缺损封堵器患儿术后12月超声心动图示左肺动脉血流速度增快.结论 应用导管介入治疗直径≥5 mm婴幼儿大型PDA是安全、有效的方法.  相似文献   

7.
目的总结第二代Amplatzer动脉导管未闭封堵器(amplatzer duct occluderⅡ,ADO-Ⅱ)介入治疗小儿先天性心脏病的疗效和经验。方法对湖南省儿童医院2014年1月至2015年6月采用ADO-Ⅱ进行封堵的24例先天性心脏病患儿临床资料进行总结。其中动脉导管未闭18例、室间隔缺损(肌部)2例以及冠状动脉瘘4例。术前经临床以及经胸超声心动图筛选,术中心导管造影结合经胸超声心动图及术后即刻和随访,观察术后残余分流、封堵器位置以及并发症。结果 16例动脉导管未闭即刻封堵成功,无残余分流,无并发症;2例动脉导管未闭即刻封堵时有少许残余分流,无其他并发症。3例冠状动脉瘘封堵器无残余分流,1例冠状动脉瘘封堵处术后1个月少许线样分流。2例室间隔缺损均即刻封堵成功,无残余分流,心电图未见明显房室传导阻滞。结论 ADO-Ⅱ封堵器以其操作相对简便、成功率高以及并发症少的优点,在把握适应证的前提下值得临床推广。  相似文献   

8.
偏心型封堵器治疗先天性干下型室间隔缺损的探讨   总被引:1,自引:0,他引:1  
目的探讨先天性干下型室间隔缺损(VSD)偏心型封堵器介入治疗的可行性及近期疗效。方法经皮介入治疗先天性干下型室间隔缺损患者7例。经胸超声心动图提示VSD的直径为4~8mm,缺损上缘距主动脉瓣的距离1~2mm,距肺动脉瓣距离4~6mm,轻度主动脉瓣反流6例,中度1例。均选用偏心型VSD封堵器治疗。术中在右前斜45度下行左室造影、建立股动静脉轨道、经右心系统释放封堵器,并分别于术后2周、1个月、3个月、6个月进行随访。结果7例患者封堵器均成功置入。术后即刻超声及造影示完全封堵6例,少量残余分流1例,在3个月后消失。封堵器对主动脉瓣、肺动脉瓣和房室瓣均无影响,术中及术后未有其它严重并发症发生。结论应用偏心型封堵器经皮介入治疗先天性干下型室间隔缺损是安全有效的,近期效果良好。  相似文献   

9.
目的 :应用 Am platzer封堵器经导管治疗动脉导管未闭 (PDA)开胸术后再通并对其疗效进行评价。方法 :全组10例 ,年龄 11± 8(4~ 32 )岁。PDA最窄处直径为 4± 4(2~ 13) mm。封堵后 10 m in行侧位降主动脉造影 ,术后 1d及 1月行超声心动图检查 ,观察有无残余分流及 PDA再通。结果 :9例 PDA采用 Am platzer PDA封堵器治疗 ,1例采用 Amplatzer房间隔缺损封堵器治疗。术后 10 m in降主动脉造影显示 ,3例存在微量~少量残余分流 ,7例封堵完全无残余分流。术后 2 4h、术后 1月超声心动图均未见残余分流及再通。结论 :应用 Amplatzer封堵器治疗动脉导管未闭外科术后再通是一种安全有效的介入方法。  相似文献   

10.
李红梅  叶季鲜  高群  代政学  张丙芳 《心脏杂志》2005,17(6):597-598,602
目的:分析国产对称双盘状封堵器经导管治疗室间隔缺损(VSD)的疗效。方法:21例,全部为膜部室间隔缺损,年龄3.035.0(7.6±8.4)岁。VSD左室面直径为2.212.0(6.2±4.2)mm。经6F-10F传送鞘置入国产对称双盘状封堵器,封堵后即刻行左心室造影,术后1 d、1、6及12月行超声心动图检查观察有无残余分流。结果:封堵器植入成功20例,植入技术成功率95%。术后即刻左心室造影示4例(20%)存在微少量残余分流,16例(80%)封堵完全无残余分流。术后2448 h超声心动图示分流完全消失19(95%)、微少量残余分流1例(5%)。1例封堵术后3 d发生一过性Ⅲ度房室传导阻滞,经过410 d内科保守治疗治愈。1月超声心动图所有病例未见残余分流。结论:应用国产双盘状封堵器治疗VSD是一种安全有效的介入方法,操作简便,成功率高,近期疗效可靠。  相似文献   

11.
目的:探讨Am p latzer封堵器和国产封堵器的临床疗效以及经胸超声心动图和χ线透视下行膜部室间隔缺损(V SD)封堵术的安全性和有效性。方法:在经胸超声心动图和χ线指导下,对15例膜部(膜周)室缺患者行室缺封堵术,术后1 d,1月,3月,6月随访心电图和超声心动图检查。结果:左室造影测量室缺的大小为3~11 mm,经胸超声心动图测量V SD大小为3~10 mm,封堵器的大小为6~14 mm。15例患儿手术成功,其中8例选择Am p latzer封堵器,7例选择国产封堵器,二者在手术时间,手术即刻和随访的成功率无显著性差异(P>0.05),二组均无严重并发症发生。患儿住院时间为5~7 d,术后复查超声心动图未见主动脉瓣,三尖瓣的关闭不全,无残余分流,心电图无房室传导阻滞。结论:(1)Am p latzer封堵器和国产封堵器性能相同;(2)膜部室间隔缺损封堵术安全,有效。  相似文献   

12.
目的 评价经胸超声心动图监测 (TTE)Amplatzer封堵器介入治疗巨大房间隔缺损(ASD)的安全性和可行性。方法  2 1例住院患者 ,男 12例 ,女 9例 ;年龄 17~ 4 5岁 ;均经临床及超声心动图证实的继发孔型ASD ,以充盈球囊最大伸展直径加 2~ 4mm为原则选择封堵器型号 ,TTE监测下放置Amplatzer封堵器。随访有无残余分流及是否影响周围瓣膜和静脉功能 ,记录临床事件 (血栓栓塞、心功能不全、心律失常等 )。结果  2 1例全部封堵成功 ,TTE监测放置Amplatzer封堵成功 ,手术成功率 10 0 % ;术后即刻及 1天、3天、3个月、6个月、1年复查TTE观察无明显残余分流及影响周围瓣膜功能 ,也无腔、肺静脉狭窄 ,无血栓栓塞事件发生 ,无封堵器移位和脱落 ,心功能有不同程度的好转。1例发生频发房性心律失常 ,经心律平 4 5 0mg d治疗 1个月后消失 ,无其他并发症发生。结论 Amp latzer封堵器介入治疗成人巨大ASD是一种安全、有效的治疗方法 ,TTE监测ASD介入封堵治疗整个过程 ,可以提高一次释放成功率  相似文献   

13.
Transcatheter closure of congenital muscular ventricular septal defect   总被引:18,自引:0,他引:18  
The success with occlusion devices for the closure of atrial septal defects and patent ductus arteriosus prompted the transcatheter closure of single and multiple muscular ventricular septal defects (VSD). The procedure for VSD was first attempted by Lock et al. in 1988 and devices originally designed for the closure of other intracardiac defects (Rashkind umbrella device, Lock clamshell, Cardioseal, coils, Sideris buttoned device etc.) were used with a variable success rate and a residual shunt. Recently, specially designed Amplatzer muscular VSD occluder and Sideris device are in use. The Amplatzer muscular VSD occluder has been undergoing clinical trial since 1998 after the animal experiments had shown 100% occlusion and complete endothelization at 3 months. The procedure was first attempted in August 1995 using the Rashkind umbrella device and since April 1998 only the Amplatzer muscular VSD occluder has been used. Of the149 patients who underwent transcatheter closure of VSD, 50 had muscular trabecular defects in various locations: mid-muscular, anterior, posterior, or apical. All cases were selected by detailed transthoracic and/or transesophageal echocardiography (TTE) and aneurysm of the muscular septum was observed in three of them. The age range was 3-28 years and the diameter of VSD was 4-11 mm. In all but one patient, the device was deployed from the venous side. Simultaneous TTE was done for proper positioning of the device and continuous electrocardiographic monitoring was also done for any arrhythmia/conduction defects. All patients were followed up every 3 months and received 3-5 mg/kg aspirin for 6 months. The procedure was successful in all patients. The Rashkind umbrella device (17 mm) was used in two and Amplatzer muscular VSD occluder (6-14 mm) in 48 patients. Forty-four devices were delivered by antegrade transvenous approach and six by the transjugular route. None had residual shunt, new aortic regurgitation, or tricuspid regurgitation. Transient complete heart block after 24 hours was noticed in one patient. On a follow-up of 2-90 months, the device was in position in all patients. There was no embolization of the device, and no late-conduction defects, infective endocarditis, or hemolysis. Transcatheter closure of muscular VSD is safe and efficacious, and should be considered as a procedure of choice as an alternative to surgery that avoids cardiopulmonary bypass.  相似文献   

14.
目的 使用彩色超声心动图监测经导管蘑菇伞堵闭先天性心脏病房间隔缺损(ASD)。方法 使用彩色超声心动图仪器对14岁以下小儿经食道,成人经胸术中监测,指导操作者安置封堵器的合适方位。当双盘蘑菇伞腰部卡在ASD内,两盘则分别在左、右房侧时,彩色超声心动图监测无残余分流后结束堵闭术,术后24小时再次进行彩色超声心动图检查。结果 37例中,36例1次堵闭成功,1例失败。结论 在经导管蘑菇伞堵闭ASD中,彩色超声心动图监测很重要。  相似文献   

15.
经静脉闭合房间隔缺损的疗效观察   总被引:4,自引:0,他引:4  
目的 :评价经静脉置入 Amplatzer封堵器治疗继发孔型房间隔缺损 (ASD)的疗效。方法 :2 4例患者术前经多普勒超声心动图检查 ASD直径为 6~ 30 (18.96± 7.0 3) m m。在透视及经超声心动图引导下经静脉置入Am platzer封堵器闭合 ASD。结果 :2 4例 ASD直径的球囊测量值为 15~ 36 (2 6 .2 5± 7.5 7) mm ,选择的封堵器直径为 14~ 36 (2 6 .5 2± 7.15 ) m m。 2 4例封堵器置入均获得成功 ,术中无并发症 ,1例在术后第 3天出现 度 型房室传导阻滞 ,2周后恢复。 7例术后即刻超声检查显示微量残余分流 ,术后 1周复查均无分流。结论 :经静脉置入 Amplatzer封堵器治疗 ASD是一种有效的非外科手术方法。  相似文献   

16.
BACKGROUND: Use of trancatheter device closure for membranous ventricular septal defect is still in evolving phase. We report the early and mid-term results of our experience with the new asymmetric Amplatzer membranous ventricular septal defect occluder. METHODS AND RESULTS: We attempted, transcatheter closure of perimembranous ventricular septal defect using asymmetric Amplatzer occluder in 26 patients. The patients were selected on the basis of transthoracic and transesophageal echocardiographic assessment of the ventricular septal defect. The procedure was successful in 21 (81%) patients. The age ranged from 3 to 23 years, weight from 10 to 59 kg and defect size ranged from 3 to 9 mm (mean: 5 +/- 1.8 mm). One patient had situs inversus with dextrocardia: 11 had aneurysmal tissue partly occluding the defect and the device was deployed either across (n=6) or within the aneurysmal sac (n=5). Three patients developed high degree atrioventricular block on attempts to cross the defect with the sheath and the procedure was discontinued. In two patients it was not possible to place the sheath in left ventricle despite repeated attempts. There was a residual flow in 4 (19%) patients at 24 hours. Two patients developed bundle branch block and none had complete heart block. At follow-up (1-9 months, n=20), residual flow was seen in two patients. None developed late conduction defect, aortic regurgitation, infective endocarditis or hemolysis. CONCLUSIONS: Transcatheter closure of perimembranous ventricular septal defect can be performed safely and effectively with the new asymmetric Amplatzer occluder device in selected patients with good short- and midterm results. These devices can be deployed safely in and across and the aneurysmal sacs. In selected cases, this procedure is a satisfactory alternative to surgery.  相似文献   

17.
目的 探讨应用Amplatzer封堵器治疗先天性心脏病心房间隔缺损 (atrialseptaldefect,ASD)及动脉导管未闭 (patentductusarteriosus ,PDA)的方法并评价其疗效。方法  2 3例患者 (ASD 19例 ,PDA 4例 )。所有病例均在X线透视、造影及食道超声心动图监视下经导管置入Amplatzer封堵器治疗ASD及PDA。结果 全组技术成功率 10 0 %。 2 3例患者术后 2 4h、1周行经胸超声心动图 (TTE)检查 ,有 2例存在残余分流 ,术后即刻完全封堵率 91 2 %。术后 6个月随访TTE检查示所有病例均封堵完全 ,无残余分流 ;X线检查全部显示肺血减少 ,心胸比例不同程度缩小。结论 经导管置入Amp latzer封堵器是治疗ASD和PDA的一种操作简便、技术成功率高、疗效可靠的介入方法。  相似文献   

18.
国产封堵器介入治疗室间隔缺损69例   总被引:3,自引:0,他引:3  
目的评价国产封堵器介入治疗室间隔缺损(VSD)的安全性及疗效。方法69例室间隔缺损(男24例,女45例),其中膜周部(PMVSD)50例、嵴内型(IVSD)9例、干下型(SVSD)8例、肌部2例。PMVSD使用对称型封堵器、IVSD和SVSD使用偏心型封堵器、膜部瘤形成合并多孔型使用对称型封堵器或大边封堵器、急性心肌梗死室间隔穿孔使用房间隔缺损(ASD)封堵器。结果左心室造影测量缺损直径3mm~12mm,平均7.67mm±1.59mm。69例中62例封堵成功,其中50例膜周部缺损,47例成功,8例SVSD4例成功,9例IVSD及2例肌部室缺均成功。1例在术中发生封堵器脱落;1例出现脑栓塞;1例出现溶血;1例Ⅲ度房室传导阻滞。结论介入治疗室间隔缺损,创伤小,成功率高,手术安全,国产封堵器安全、可靠。  相似文献   

19.
目的:评价在经胸超声心动图(TTE)监测下用Amplatzer封堵器介入治疗房间隔缺损(ASD)的可行性及实用价值。方法:全组共18例继发孔型ASD患者,均在常规C型臂X线机透视和TTE指导下经导管置入Amplatzer封堵器。结果:18例患者中有2例未放置成功而改为开胸手术;16例均成功置入Amplatzer封堵器,即刻完全堵闭,术后随访3个月至2年,TTE示ASD仍被完全封闭,未见残余分流。随访期间无任何并发症。结论:在TTE和X线透视指导下用Amplatzer封堵器治疗继发孔型ASD安全可行,具有一定实用价值。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号