Purpose

Individual physiological knee kinematics are highly variable in normal knees and are altered following cruciate-substituting (PS) and cruciate-retaining (CR) total knee arthroplasty (TKA). We wanted to know whether knee kinematics are different choosing two different knee designs, CR and PS TKA, during surgery using computer navigation.

Methods

For this purpose, 60 consecutive TKA were randomised, receiving either CR (37 patients) or PS TKA (23 patients). All patients underwent computer navigation, and kinematics were assessed prior to making any cuts or releases and after implantation. Outcome measures were relative rotation between femur and tibia, measured medial and lateral gaps and medial and lateral condylar lift-off.

Results

We were not able to demonstrate a significant difference in femoral external rotation between either group prior to implantation (7.9° CR vs. 7.4° PS) or after implantation (9.0° CR vs. 11.3° PS), both groups showed femoral roll-back. It significantly increased pre- to postoperatively in PS TKA. In the CR group both gaps increased, the change of the medial gap was significantly attributable to medial release. In the PS group both gaps increased and the change of the medial and of the lateral gap was significant. Condylar lift-off was observed in the CR group during 20° and 60° of flexion.

Conclusion

This study did not reveal significant differences in navigation-based knee kinematics between CR and PS implants. Femoral roll-back was observed in both implant designs, but significantly increased pre- to postoperatively in PS TKA. A slight midflexion instability was observed in CR TKA. Intra-operative computer navigation can measure knee kinematics during surgery before and after TKR implantation and may assist surgeons to optimise knee kinematics or identify abnormal knee kinematics that could be corrected with ligament releases to improve the functional result of a TKR, whether it is a CR or PS design. Our intra-operative finding needs to be confirmed using fluoroscopic or radiographic 3D matching after complete recovery from surgery.  相似文献   

2.

Background

Joint function and durability after TKA depends on many factors, but component alignment is particularly important. Although the transepicondylar axis is regarded as the gold standard for rotationally aligning the femoral component, various techniques exist for tibial component rotational alignment. The impact of this variability on joint kinematics and stability is unknown.

Questions/purposes

We determined how rotationally aligning the tibial component to four different axes changes knee stability and passive tibiofemoral kinematics in a knee after TKA.

Methods

Using a custom surgical navigation system and stability device to measure stability and passive tibiofemoral motion, we tested 10 cadaveric knees from five hemicorpses before TKA and then with the tibial component aligned to four axes using a modified tibial tray.

Results

No changes in knee stability or passive kinematics occurred as a result of the four techniques of tibial rotational alignment. TKA produces a ‘looser’ knee over the native condition by increasing mean laxity by 5.2°, decreasing mean maximum stiffness by 4.5 N·m/°, increasing mean anterior femoral translation during passive flexion by 5.4 mm, and increasing mean internal-external tibial rotation during passive flexion by 4.8°. However, no statistically or clinically important differences occurred between the four TKA conditions.

Conclusions

For all tibial rotations, TKA increased laxity, decreased stiffness, and increased tibiofemoral motion during passive flexion but showed little change based on the tibial alignment.

Clinical Relevance

Our observations suggest surgeons who align the tibial component to any of the axes we examined are expected to have results consistent with those who may use a different axis.  相似文献   

3.

Background

Historically, knee arthroplasties have been designed using average patient anatomy. Recent advances in imaging and manufacturing have facilitated the development of customized prostheses designed to fit the unique shape of individual patients. The purpose of this study is to determine if improving implant design through customized total knee arthroplasty (TKA) improves kinematic function.

Methods

Using state-of-the-art mobile fluoroscopy, tibiofemoral kinematics were analyzed for 24 subjects with a customized individually made (CIM), cruciate-retaining TKA, and 14 subjects having an asymmetric condylar cruciate-retaining TKA. Subjects performed a weight-bearing deep knee bend and a rise from a seated position. Each patient was evaluated for weight-bearing range of motion, femorotibial translation, femorotibial axial rotation, and condylar liftoff occurrence.

Results

Subjects having a CIM TKA experienced greater weight-bearing knee flexion compared with the traditional posterior cruciate-retaining (PCR) TKA design. During flexion, the CIM TKA subjects consistently exhibited more posterior femoral rollback than the traditional PCR TKA subjects. The CIM TKA was found to have statistically greater axial rotation compared with the traditional PCR TKA (P = .05). Of note, only the CIM TKA patients experienced femoral internal rotation at full extension, as exhibited in a normal knee. Compared with the traditional PCR TKA, the CIM TKAs demonstrated minimal occurrences of paradoxical sliding and reverse rotation during flexion and extension. The CIM TKA subjects showed minimal liftoff and hence better stability in earlyflexion to midflexion compared with the traditional PCR subjects.

Conclusion

The CIM TKA demonstrated kinematics more similar to a normal knee. Therefore, using customized implant technology through CIM TKA designs affords benefits including more normal motion compared with a traditional PCR TKA.  相似文献   

4.

Purpose

Posterior stabilised (PS) total knee arthroplasty (TKA) design development that focused on restoring normal knee kinematics was followed by the introduction of reason-guided motion designs. Although all PS fixed-bearing knee designs were thought to have similar kinematics, reports show they have differing incidences and magnitudes of posterior femoral rollback and axial rotation. In this retrospective comparative study between two guided-motion total knee systems, we hypothesised that kinematic pattern has an influence on clinical and functional outcomes.

Methods

This study represents the continuation of a previously reported clinical and kinematics analysis. We retrospectively reviewed 347 patients treated with two different TKA designs: Scorpio NRG (Stryker Orthopedics) and Journey Bi-Cruciate Stabilised (BCS) knee system (Smith & Nephew). Two hundred and eighty-one patients were assessed clinically. Patients were divided into groups according to implanted TKA. Clinical evaluation with the Knee Injury and Osteoarthritis Outcome Score (KOOS) questionnaire was performed. Fifteen Scorpio NRG and 16 Journey BCS patients underwent video fluoroscopy during stair climbing, chair rising/sitting and step up/down at six months of follow-up.

Results

At an average 29 months of clinical follow-up, patients with Journey BCS TKAs reported better clinical results. Stiffness was more frequently reported in the Journey group (5.2 % vs 1.2 %), whereas anterior knee pain was observed in the Scorpio NRG group (1.9 %) only. Both prosthetic models reported different posterior translation of the medial and lateral contact points (CP) in all analysed motor tasks during knee flexion (BCS 10–18 mm; NRG Scorpio 2–3 mm). Both designs produced progressive external rotation of the femoral component relative to the tibia during flexion.

Conclusions

Journey BCS showed statistically significant better KOOS results. The higher posterior femoral rollback observed in the kinematic assessment of this design, associated with a better patellofemoral design, may be the reason for better clinical outcome. The reported cases of stiffness and anterolateral joint pain could be attributed to excessive medial and lateral tibiofemoral posterior translation. The NRG group demonstrated good axial rotation, but this was not coupled with physiological kinematic patterns. Patellofemoral pain can be explained by a less friendly femoral-groove design. TKA clinical–functional outcome and complications were highly influenced by the bearing geometry and kinematic pattern of prosthetic designs.  相似文献   

5.
《The Journal of arthroplasty》2020,35(6):1712-1719
BackgroundEarly total knee arthroplasty (TKA) designs were symmetrical, but lead to complications due to over-constraint leading to loosening and poor flexion. Next-generation TKAs have been designed to include asymmetry, pertaining to the trochlear groove, femoral condylar shapes, and/or the tibial component. More recently, an advanced posterior cruciate sacrificing (PCS) TKA was designed to include both a symmetrical femoral component with a patented V-shaped trochlear groove and a symmetrical tibial component with an ultracongruent insert, in an attempt to reduce inventory costs. Because previous PCS TKA designs produced variable results, the objective of this study is to determine and evaluate the in vivo kinematics for subjects implanted with this symmetrical TKA.MethodsTwenty-one subjects, implanted with symmetrical PCS fixed-bearing TKA, were asked to perform a weight-bearing deep knee bend (DKB) while under fluoroscopic surveillance. A 3-dimensional to 2-dimensional registration technique was used to determine each subject’s anteroposterior translation of lateral and medial femoral condyles as well as tibiofemoral axial rotation and their weight-bearing knee flexion.ResultsDuring the DKB, the average active maximum weight-bearing flexion was 111.7° ± 13.3°. On average, from full extension to maximum knee flexion, subjects experienced −2.5 ± 2.0 mm of posterior femoral rollback of the lateral condyle and 2.5 ± 2.2 mm of medial condyle motion in the anterior direction. This medial condyle motion was consistent for the majority of the subjects, with the lateral condyle exhibiting rollback from 0° to 60° of flexion and then experienced an average anterior motion of 0.3 mm from 60° to 90° of knee flexion. On average, the subjects in this study experienced 6.6°± 3.3° of axial rotation, with most of the rotation occurring in early flexion, averaging 4.9°.ConclusionAlthough subjects in this study were implanted with a symmetrical PCS TKA, they did experience femoral rollback of the lateral condyle and a normal-like pattern of axial rotation, although less in magnitude than the normal knee. The normal axial rotation pattern occurred because the lateral condyle rolled in the posterior direction, while the medial condyle moved in the anterior direction. Interestingly, the magnitude of posterior femoral rollback and axial rotation for subjects in this study was similar in magnitude reported in previous studies pertaining to asymmetrical TKA designs. It is proposed that more patients be analyzed having this TKA implanted by other surgeons.  相似文献   

6.

Background

The patterns and magnitudes of axial femorotibial rotation are variable due to the prosthesis design, ligamentous balancing, and surgical procedures. We aimed to investigate the effects of the weight bearing (WB) condition on the kinematics of mobile-bearing total knee arthroplasty (TKA).

Methods

We examined 12 patients (19 knees) implanted with a low contact stress (LCS) mobile-bearing TKA system using a two-dimensional to three-dimensional registration technique. The in vivo kinematics of dynamic deep knee flexion under WB and non-WB (NWB) conditions were compared. We evaluated the knee range of motion, femoral axial rotation relative to the tibial component, anteroposterior translation, and kinematic pathway of the femorotibial contact point for both the medial and lateral sides.

Results

Under the WB condition, the mean range of motion was 117.8° ± 16.7°. Under the NWB condition, the mean range of motion was 111.0° ± 4.4°. The mean range of axial rotation from full extension to maximum flexion was 3.0° ± 1.5° under the WB condition and 2.2° ± 1.0° under the NWB condition. With regard to the anteroposterior translation, the LCS mobile-bearing TKA system showed the same kinematic patterns under both conditions, except for axial rotation at 0°, 10°, and 110°. From hyperextension to maximum flexion, the kinematic pattern reflected a central pivot under both conditions.

Conclusions

In conclusion, this study demonstrated that, in an LCS mobile-bearing TKA system, knee kinematics showed the same patterns under NWB and WB conditions, except for axial rotation at the early phase. Further understanding of knee kinematics could provide us with useful information for future design concepts of TKA implants.  相似文献   

7.

Background

Coronal alignment is considered key to the function and longevity of a TKA. However, most studies do not consider femoral and tibial anatomical features such as lateral femoral bowing and the effects of these features and subsequent alignment on function after TKA are unclear.

Questions/purposes

We therefore determined (1) the prevalence of lateral femoral bowing, varus femoral condylar orientation, and severe tibia plateau inclination in female Koreans undergoing TKA; (2) whether postoperative alignments are affected by these anatomical features and improved by the use of navigation; and (3) whether postoperative coronal alignments are associated with function.

Methods

We measured alignment in 367 knees that underwent TKA and 60 sex- and age-matched normal knees (control group). We determined patterns and degrees of femoral bowing angle, femoral condylar orientation, and tibial plateau inclination on preoperative full-limb radiographs. Postoperatively, coronal alignment of limbs and of femoral and tibial components was measured. We compared American Knee Society scores, WOMAC scores, and SF-36 scores in aligned knees and outliers (beyond ± 3° or ± 2°) at 1 year.

Results

The prevalence of lateral femoral bowing was 88% in the TKA group and 77% in the control group. Mean femoral condylar orientation angle was varus 2.6° in the TKA group and valgus 1.1° in the control group, and mean tibial plateau inclination was varus 8.3° in the TKA group and varus 5.4° in the control group. Femoral lateral bowing and varus femoral condylar orientation were associated with postoperative alignments. Several clinical outcome scales were inferior in the outliers in mechanical tibiofemoral angle, anatomical tibiofemoral angle, and tibial coronal alignment but not in femoral coronal alignment outliers.

Conclusions

Lateral femoral bowing, varus condylar orientation, and severe varus inclination of the tibia plateau should be considered when performing TKA in Korean patients or patients with otherwise similar anatomical features.  相似文献   

8.

Purpose

To investigate the effects of a trial femoral component on the intraoperative joint gap and intraoperative joint gap kinematics throughout the range of knee motion in minimally invasive surgery–total knee arthroplasty (MIS–TKA) with the gap technique.

Materials and methods

A total of 103 patients [15 men (15 knees) and 89 women (89 knees)] aged 50–88 years (mean 74.8 years) who received MIS–TKA with the gap technique were included. The intraoperative joint gap differences (90° flexion gap distance minus 0° extension gap distance) with and without the trial femoral component were compared. Subsequently, the intraoperative joint gap kinematics at 0°, 45°, 90°, and 120° with the trial femoral component were investigated.

Results

The intraoperative component gap difference (4.4 ± 2.7 mm) was larger than the estimated joint gap difference (1.2 ± 1.9 mm) (p < 0.01). The mean intraoperative component gap distances at 0°, 45°, 90°, and 120° of knee flexion were 14.7 ± 2.6, 19.0 ± 3.2, 19.2 ± 3.4, and 16.6 ± 3.3 mm, respectively. The intraoperative component gap distance increased significantly from 0° extension to 90° of knee flexion (p < 0.01), and then decreased significantly toward deep knee flexion at 120° (p < 0.01).

Conclusions

The trial femoral component influenced the intraoperative gap measurements, and increased the intraoperative gap difference. The joint gap kinematics with the trial femoral component were not constant throughout the range of knee motion, even if the appropriate joint gaps in extension and flexion were achieved. For acquisition of constant stability throughout the knee motion, the present results should be taken into account by surgeons performing MIS–TKA with the gap technique.  相似文献   

9.
 目的 通过透视技术结合数字化模型注册技术分析全膝关节置换术后股骨假体与胫骨垫片之间的相对运动和接触位置。方法 2007年7月至2008年6月,接受GENESISⅡ假体全膝关节置换术患者16例,均为女性;年龄56~76岁,平均66.4岁。随访48~60个月,平均(56±3)个月。采用膝关节学会评分(Knee Society Score,KSS)评价膝关节功能;采用循环透视方法获取影像学数据,对假体逆向数字建模,进行数字模型和影像学数据的匹配,重建膝关节的三维运动;测量股骨内、外髁接触位置的移动,计算胫骨内旋角度,测量股骨凸轮和胫骨立柱的接触时相和范围。结果 末次随访时KSS膝评分(93±5)分,功能评分(88±13)分,与术前比较差异有统计学意义。股骨内髁的移动范围(8.5±2.5) mm,外髁的移动范围(9.5±4.8) mm,胫骨内旋角度2.5°±8.4°。屈膝约30°~40°时凸轮和立柱发生接触,立柱后方的接触范围(8.0±1.8) mm。胫骨平台后倾角度越大,凸轮和立柱的接触越晚。结论 全膝关节置换术后股胫关节的运动学特征与正常膝关节不同,膝关节屈曲10°~30°时股骨内髁前移,屈曲大于40°后股骨内、外髁后移,胫骨平台后倾与凸轮和立柱的接触时相有相关性。  相似文献   

10.

Background  

In modern total knee arthroplasty (TKA), it is important to reproduce both medial pivot motion and posterior femoral rollback to obtain greater postoperative knee flexion. Several studies have reported the factors affecting knee motion and range of motion after TKA. The purpose of this study was to evaluate the effect of the tibial insert geometry on the tibiofemoral contact kinematics, especially focusing on the medial pivot motion and posterior femoral rollback.  相似文献   

11.

Background

It has been widely accepted in total knee arthroplasty (TKA) that flexion and extension gaps in the disarticulated knee during surgery should be equalized. We hypothesized that tensioning during assessment of the flexion gap can induce temporary widening of the gap due to posterior tibial translation. We aimed to describe posterior tibial translation at flexion gap (90°) assessments and assess the correlation of tibial translation with laxity (flexion space increase) using constrained and non-constrained inserts.

Methods

Imageless navigation was used to measure flexion angle, tibial position relative to the femoral axis, and lateral/medial laxity in 30 patients undergoing primary TKA. Trialing was conducted using posteriorly stabilized and cruciate retaining trials of the same size to elucidate the association of posterior tibial translation with changes in joint capsule laxity at 90° knee flexion.

Results

All patients demonstrated posterior tibial translation during flexion gap assessment relative to their subsequent final implantation [mean ± standard deviation (range), 11.3 ± 4.4 (4-21) mm]. Positive linear correlation [r = 0.69, 95% confidence interval (CI) 0.44-0.84, P ≤ .001] was demonstrated between translations [8.7 ± 2.4 (3-13) mm] and laxity changes [2.9° ± 2.0° (?0.7° to 7.4°)] at 90° of flexion.

Conclusion

Posterior tibial translation can cause artifactual widening of the flexion gap during gap balancing in posteriorly stabilized TKA, which can be of sufficient magnitude to alter femoral component size selection for some patients. Recognition and management of these intra-operative dynamics for optimal kinematics could be feasible with the advent of robotic applications.  相似文献   

12.

Background

Bi-cruciate retaining (BCR) total knee arthroplasty (TKA) preserves both anterior and posterior cruciate ligaments with the potential to restore normal posterior femoral rollback and joint kinematics. However, there is limited information regarding articular contact behavior in the contemporary BCR TKA design during high knee flexion activities. This study aimed to investigate the articular knee contact performance in unilateral BCR TKA patients during strenuous flexion activities.

Methods

Twenty-nine unilateral BCR TKA patients were evaluated for both knees during single deep lunges, step-ups, and sit-to-stand (STS) using a validated combined computer tomography and dual fluoroscopic imaging system. Medial and lateral condylar contact positions were quantified during weight-bearing flexion.

Results

Contact excursions of the lateral condyle in BCR TKAs were significantly more anteriorly located than the contralateral non-operated knees during STS (?4.9 ± 3.1 vs ?9.7 ± 4.6 mm, P < .05), single deep lunge (?5.7 ± 3.2 vs ?10.0 ± 4.5 mm, P < .05), and step-ups (?4.8 ± 3.6 vs ?9.1 ± 3.9 mm, P < .05). Contact points of BCR TKAs indicated reduced femoral external rotation during STS (2.1 ± 4.8° vs 7.7 ± 5.4°, P < .05), single deep lunges (1.8 ± 4.8° vs 7.0 ± 7.1°, P < .05), and step-ups (0.1 ± 4.1° vs 6.2 ± 4.9°, P < .05). Medial pivoting patterns were observed in only 59%, 56%, and 48% of the BCR TKA knees for step-ups, STS, and single deep lunge, respectively.

Conclusion

The contemporary BCR TKA design demonstrated asymmetric femoral rollback, medial translation, as well as lateral pivoting in about half of the patient cohort, suggesting that in vivo tibiofemoral kinematic parameters were not fully restored in BCR patients during strenuous flexion activities.  相似文献   

13.

Purpose

Increasing the tibial slope is often performed if the flexion gap is narrower than the extension gap. The main hypothesis of this study is that increasing the tibial slope coincidentally enlarges the extension gap.

Methods

Twenty formalin-fixed cadaveric knees were obtained for study. After CT in full extension and 90° flexion, the data of each specimen were entered into a standardized coordinate system and virtual bone cuts were performed with incrementally increasing the posterior slope. Gaps were measured at tibiofemoral contact points in 90°-flexion and full extension in the medial and lateral compartment.

Results

Increasing the tibial slope did significantly widen both the extension and the flexion gaps (p?p?Conclusions Increasing the tibial slope beyond the pre-operative planning in order to widen a tight flexion gap intra-operatively is not recommended as doing so will increase the extension gap simultaneously and will make the medial and lateral flexion gaps unequal.  相似文献   

14.
15.

Background

During modified gap-balancing technique, there is no consensus on the best method for obtaining appropriate soft-tissue balance and determining the femoral component rotation.

Methods

Sixty-five varus osteoarthritic patients underwent primary posterior-stabilized total knee arthroplasty using modified gap-balancing technique. The influence of joint distraction force on the soft-tissue balance measurement during the modified gap-balancing technique was evaluated with Offset Repo-Tensor between the osteotomized surfaces at extension, and between femoral posterior condyles and tibial osteotomized surface at flexion of the knee before the resection of femoral posterior condyles. The joint center gap (millimeters) and varus ligament balance (°) were measured under 20, 40, and 60 pounds of joint distraction forces, and the differences in these values at extension and flexion (the value at flexion minus the value at extension) were also calculated.

Results

The differences in joint center gap (?6.7, ?6.8, and ?6.9 mm for 20, 40, and 60 pounds, respectively) and varus ligament balance (3.5°, 3.8°, and 3.8°) at extension and flexion were not significantly different among different joint distraction forces, although the joint center gap and varus ligament balance significantly increased stepwise at extension and flexion as the joint distraction force increased.

Conclusion

The difference in joint center gap and varus ligament balance at extension and flexion were consistent even among the different joint distraction forces. This novel index would be useful for the determination of femoral component rotation during the modified gap-balancing technique.  相似文献   

16.

Purpose

Our aim was to evaluate tunnel-graft angle, tunnel length and position and change in graft length between transtibial (30 patients) and anteromedial (30 patients) portal techniques using 3D knee models after anterior cruciate ligament (ACL) reconstruction.

Methods

The 3D angle between femoral or tibial tunnels and graft at 0° and 90° flexion were compared between groups. We measured tunnel lengths and positions and evaluated the change in graft length from 0° to 90° flexion.

Results

The 3D angle at the femoral tunnel with graft showed a significant difference between groups at 0° flexion (p?=?0.01) but not at 90° flexion (p?=?0.12). The 3D angle of the tibial tunnel showed no significant differences between groups. Femoral tunnel length in the transtibial group was significantly longer than in the transportal group (40.7 vs 34.7 mm,), but tibial tunnel length was not. The relative height of the lateral femoral condyle was significantly lower in the transportal than the transtibial group (24.1 % vs 34.4 %). No significant differences were found between groups in terms of tibial tunnel position. The change in graft length also showed no significant difference between groups.

Conclusion

Even though the transportal technique in ACL reconstruction can place the femoral tunnel in a better anatomical position than the transtibial technique, it has risks of a short femoral tunnel and acute angle at the femoral tunnel. Moreover, there was also no difference in the change of the graft length between groups.  相似文献   

17.

Background

The bicruciate stabilized (BCS) total knee arthroplasty (TKA) features asymmetrical bearing geometry and dual substitution for the anterior cruciate ligament and posterior cruciate ligament (PCL). Previous TKA designs have not fully replicated normal knee motion, and they are characterized by lower magnitudes of overall rollback and axial rotation than the normal knee.

Methods

In vivo kinematics were derived for 10 normal knees and 40-second generation BCS TKAs all implanted by a single surgeon. Mobile fluoroscopy and three-dimensional-to-two-dimensional registration was used to analyze anterior-posterior motion of the femoral condyles and femorotibial axial rotation during weight-bearing flexion. Statistical analysis was conducted at the 95% confidence level.

Results

From 0° to 30° of knee flexion, the BCS subjects exhibited similar patterns of femoral rollback and axial rotation compared to normal knee subjects. From 30° to 60° of knee flexion, BCS subjects experienced negligible anterior-posterior motions and axial rotation while normal knees continued to rollback and externally rotate. Between 60° and 90° the BCS resumed posterior motion and, after 90°, axial rotation increased in a normal-like fashion.

Conclusion

Similarities in early flexion kinematics suggest that the anterior cam-post is supporting normal-like anterior-posterior motion in the BCS subjects. Likewise, lateral femoral rollback and external rotation of the femur in later flexion provides evidence for appropriate substitution of the PCL via the posterior cam-post. Being discrete in nature, the dual cam-post mechanism does not lend itself to adequate substitution of the cruciate ligaments in mid-flexion during which anterior cruciate ligament tension is decreasing and PCL tension is increasing in the normal knee.  相似文献   

18.

Background  

Stiffness complicating TKA is a complex and multifactorial problem. We suspected internally rotated components compromised motion because of pain, patellar maltracking, a tight medial flexion gap, and limited femoral rollback on a conforming lateral tibial condyle.  相似文献   

19.

Background

Computer-aided surgery aims to improve implant alignment in TKA but has only been adopted by a minority for routine use. A novel approach, navigated freehand bone cutting (NFC), is intended to achieve wider acceptance by eliminating the need for cumbersome, implant-specific mechanical jigs and avoiding the expense of navigation.

Questions/Purposes

We determined cutting time, surface quality, implant fit, and implant alignment after NFC of synthetic femoral specimens and the feasibility and alignment of a complete TKA performed with NFC technology in cadaveric specimens.

Methods

Seven surgeons prepared six synthetic femoral specimens each, using our custom NFC system. Cutting times, quality of bone cuts, and implant fit and alignment were assessed quantitatively by CT surface scanning and computational measurements. Additionally, a single surgeon performed a complete TKA on two cadaveric specimens using the NFC system, with cutting time and implant alignment analyzed through plain radiographs and CT.

Results

For the synthetic specimens, femoral coronal alignment was within ± 2° of neutral in 94% of the specimens. Sagittal alignment was within 0° to 5° of flexion in all specimens. Rotation was within ± 1° of the epicondylar axis in 97% of the specimens. The mean time to make cuts improved from 13 minutes for the first specimen to 9 minutes for the fourth specimen. TKA was performed in two cadaveric specimens without complications and implants were well aligned.

Conclusions

TKA is feasible with NFC, which eliminates the need for implant-specific instruments. We observed a fast learning curve.

Clinical Relevance

NFC has the potential to improve TKA alignment, reduce operative time, and reduce the number of instruments in surgery. Fewer instruments and less sterilization could reduce costs associated with TKA.  相似文献   