首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 656 毫秒
1.
PurposeTo compare electromagnetic navigation (EMN) with computed tomography (CT) fluoroscopy for guiding percutaneous biopsies in the abdomen and pelvis.Materials and MethodsA retrospective matched-cohort design was used to compare biopsies in the abdomen and pelvis performed with EMN (consecutive cases, n = 50; CT-Navigation; Imactis, Saint-Martin-d’Hères, France) with those performed with CT fluoroscopy (n = 100). Cases were matched 1:2 (EMN:CT fluoroscopy) for target organ and lesion size (±10 mm).ResultsThe population was well-matched (age, 65 vs 65 years; target size, 2.0 vs 2.1 cm; skin-to-target distance, 11.4 vs 10.7 cm; P > .05, EMN vs CT fluoroscopy, respectively). Technical success (98% vs 100%), diagnostic yield (98% vs 95%), adverse events (2% vs 5%), and procedure time (33 minutes vs 31 minutes) were not statistically different (P > .05). Operator radiation dose was less with EMN than with CT fluoroscopy (0.04 vs 1.2 μGy; P < .001), but patient dose was greater (30.1 vs 9.6 mSv; P < .001) owing to more helical scans during EMN guidance (3.9 vs 2.1; P < .001). CT fluoroscopy was performed with a mean of 29.7 tap scans per case. In 3 (3%) cases, CT fluoroscopy was performed with gantry tilt, and the mean angle out of plane for EMN cases was 13.4°.ConclusionsPercutaneous biopsies guided by EMN and CT fluoroscopy were closely matched for technical success, diagnostic yield, procedure time, and adverse events in a matched cohort of patients. EMN cases were more likely to be performed outside of the gantry plane. Radiation dose to the operator was higher with CT fluoroscopy, and patient radiation dose was higher with EMN. Further study with a wider array of procedures and anatomic locations is warranted.  相似文献   

2.
PurposeTo evaluate the feasibility of a new technique for imaging-guided de novo retrograde ureteral double J (DJ) stent placement without cystoscopy in women.Materials and MethodsEighty-four women referred for ureteral stent placement between April 2019 and January 2022 were included. In all the patients, the initial attempt for stent placement was performed in a retrograde fashion. Successful ureteral catheterization and DJ stent placement were considered as technical success. The fluoroscopy time required to catheterize the ureter and that for the entire procedure were recorded. Factors affecting the technical success rate and fluoroscopy time were examined.ResultsA total of 108 ureteral stent placement procedures in 84 women, with a mean age of 57.5 years (range, 19–85 years), were performed. The most common underlying pathologies were cervical (n = 33, 31%) and ovarian (n = 32, 30%) carcinomas. The most commonly involved segments of the ureter were the lower half (n = 44, 40%) and trigone (n = 39, 36%). The technical success rate was 81.5%, and it reached 93% in the case of lower-half ureteral obstruction. Distorted trigonal anatomy caused by external compression of the bladder wall by a mass was associated with a higher rate of technical failure (90.6% vs 47.8%; P < .001). The use of ultrasound guidance to guide the sheath to the ureteral orifice allowed for a significant decrease in the fluoroscopy time for ureteral catheterization (4.6 minutes ± 3.91 vs 2.26 minutes ± 2.32; P = .003) and that for the entire procedure (9.42 minutes ± 4.95 vs 5.93 minutes ± 4.06; P = .001).ConclusionsImaging-guided de novo retrograde ureteral catheterization and stent placement can be successfully performed in a high percentage of patients within a reasonable fluoroscopy time without the need for cystoscopy in women.  相似文献   

3.
PurposeTo compare procedure and fluoroscopy time, technical and clinical success, and costs between single-use and reusable endoscopes in patients undergoing percutaneous biliary endoscopy (PBE) with lithotripsy.Material and MethodsThirty-four patients (67 procedures) were retrospectively included in the study. The patients were treated with PBE for gallstone removal from October 24, 2014, to February 12, 2020, using reusable (28 procedures) or single-use (39 procedures) endoscopes. The procedure time, fluoroscopy time, technical success rate (accessing the biliary system and locating the gallstone), clinical success rate (at least partial gallstone removal), complication rate, and cost of use were compared between the procedures.ResultsThe mean (± standard deviation) procedure time was not significantly different between single-use (136 minutes ± 45) and reusable endoscopes (136 minutes ± 51) (P = .47). The mean fluoroscopy time was significantly shorter for single-use endoscopes (11 minutes ± 8.4) than for reusable endoscopes (18 minutes ± 12) (P = .01). When comparing single-use versus reusable endoscopes, the technical success (95% [n = 37] vs 93% [n = 26]) and the clinical success (90% [n = 35] vs 75% [n = 21]) rates were not significantly different (both, P > .05). Only 1 complication was noted in the reusable endoscope group (P = .42). The cost per case was lower for single-use ($1,500) than for reusable ($3,987) endoscope procedures, primarily due to differences in capital costs and repair costs.ConclusionsSingle-use endoscopes offer the potential for lower patient radiation exposure and lower cost per case, which may reduce the financial barriers to offering PBE in interventional radiology practices. The clinical and technical success rates did not differ by endoscope type.  相似文献   

4.
PurposeTo determine the oncologic outcomes and safety profile of image-guided percutaneous cryoablation (PCA) for extraspinal thyroid cancer bone metastases with curative intent.Materials and MethodsBetween January 2010 and January 2020, 16 consecutive patients (8 men, 8 women; mean age, 61 years ± 19; range, 30–84 years) with 18 bone metastases (median bone tumor size, 19 mm; interquartile range [IQR], 12–29 mm; range, 7–58 mm) underwent PCA of oligometastatic extraspinal bone metastases. Thirteen (81%) patients were radioiodine therapy resistant. Two patients underwent 2 bone tumor ablations in a single session. Procedural data, oncologic outcomes, follow-up (with magnetic resonance imaging and positron emission tomography–computed tomography), and adverse events were retrospectively investigated. Local tumor progression-free survival, disease-free survival, and overall survival were estimated using the Kaplan-Meier method.ResultsA median of 2 cryoprobes (IQR, 1.25–3 cryoprobes; range, 1–7 cryoprobes) were used, with 2 freezing cycles; the median length of freezing was 20 minutes (IQR, 17–20 minutes; range, 10–20 minutes). The technical success was 100% (18/18), and the primary technical efficacy was 94.4% (17/18). The median follow-up was 68 months (IQR, 38–93 months). During follow-up, 3 of 17 (17.6%) tumors demonstrated local progression at 7, 13, and 27 months. Consequently, the 1-, 2-, 3-, 4-, and 5-year local tumor progression-free survivals were 93.3%, 84.6%, 76.9%, 75%, and 72.7%, respectively. Two of 16 (12.5%) patients died during follow-up at 43 and 88 months. The major adverse event rate was 5.5% (1/18) with 1 postablative acromion fracture.ConclusionsPCA for extraspinal thyroid cancer bone metastases demonstrated high local tumor control rates with a safe profile at long-term follow-up.  相似文献   

5.
PurposeTo determine whether a single 10-mg intravenous dose of the promotility agent metoclopramide reduces the fluoroscopy time, radiation dose, and procedure time required for gastrojejunostomy (GJ) tube placement.MethodsThis prospective, randomized, double-blind, placebo-controlled trial enrolled consecutive patients who underwent primary GJ tube placement at a single institution from April 10, 2018, to October 3, 2019. Exclusion criteria included age less than 18 years, inability to obtain consent, metoclopramide allergy or contraindication, and altered pyloric anatomy. Average fluoroscopy times, radiation doses, and procedure times were compared using t-tests. The full study protocol can be found at www.clinicaltrials.gov (NCT03331965).ResultsOf 110 participants randomized 1:1, 45 received metoclopramide and 51 received placebo and underwent GJ tube placement (38 females and 58 males; mean age, 55 ± 18 years). Demographics of the metoclopramide and placebo groups were similar. The fluoroscopy time required to advance a guide wire through the pylorus averaged 1.6 minutes (range, 0.3–10.1 minutes) in the metoclopramide group versus 4.1 minutes (range, 0.2–27.3 minutes) in the placebo group (P = .002). Total procedure fluoroscopy time averaged 5.8 minutes (range, 1.5–16.2 minutes) for the metoclopramide group versus 8.8 minutes (range, 2.8–29.7 minutes) for the placebo group (P = .002). Air kerma averaged 91 mGy (range, 13–354 mGy) for the metoclopramide group versus 130 mGy (range, 24–525 mGy) for the placebo group (P = .04). Total procedure time averaged 16.4 minutes (range, 8–51 minutes) for the metoclopramide group versus 19.9 minutes (range, 6–53 minutes) for the placebo group (P = .04). There were no drug-related adverse events and no significant differences in procedure-related complications.ConclusionsA single dose of metoclopramide reduced fluoroscopy time by 34%, radiation dose by 30%, and procedure time by 17% during GJ tube placement.  相似文献   

6.
PurposeTo evaluate the technical and clinical success of endovascular lymphatic decompression via thoracic duct (TD) stent placement in patients with cirrhosis with refractory ascites.Materials and MethodsNine patients (6 men and 3 women; median age, 66 [interquartile range {IQR}, 65–68] years; range, 62–78 years) who underwent TD stent placement for refractory ascites with contraindications for liver transplantation and transjugular intrahepatic portosystemic shunt creation were included in this retrospective study. TD stent placement was performed under local anesthesia using retrograde access from the venous system. Self-expanding stents from 5 to 8 mm in diameter were used and extended into the subclavian vein by approximately 1 cm. Technical (correct positioning of the stent) and clinical success (no more requirement of paracentesis) were evaluated. In addition, the safety of the procedure and TD pressure evolution were evaluated.ResultsThe technical success rate was 100%, and 3 (33%) patients reported clinical success. Five (56%) patients reported 7 minor adverse events (Grade I), among which 2 TD perforations were induced by stent angioplasty, with no clinical manifestation or treatment required. The median TD pressure decreased from 19 mm Hg (IQR, 11–24 mm Hg) at the beginning of the procedure to 6 mm Hg (IQR, 5–11 mm Hg) after TD stent placement. The median survival time after the procedure was 7.1 months.ConclusionsEndovascular lymphatic decompression via TD stent placement is feasible and safe and was effective on ascites in some patients with cirrhosis with refractory ascites.  相似文献   

7.
PurposeTo evaluate the safety and effectiveness of sequential sutures and plugged vascular closure devices (VCDs) for large-bore access closure during percutaneous access endovascular aneurysm repair (PEVAR).Materials and MethodsData on 16 patients who underwent PEVAR at the authors’ center from January 2022 to May 2022 were retrospectively reviewed. The median age was 72 years (interquartile range [IQR], 59–75 years), with a male-to-female ratio of 3:1. All patients received sequential suture and plug VCDs using dual Exoseal after 1 Proglide for access closure. Success was defined as the ability to achieve complete hemostasis and was confirmed by ultrasonography. The patients were followed up for access-related adverse events at 30 and 90 days after the procedure, and the severity was graded according to the Society of Interventional Radiology (SIR) classification.ResultsOverall, 24 access sites were included. The median sheath size was 21 F (IQR, 18–23 F). The median hemostasis time was 11.0 minutes (IQR, 9.3–13.0 minutes), the median procedural time was 133.5 minutes (IQR, 102.5–151.0 minutes), and the median length of stay was 5 days (IQR, 4.0–6.8 days). The success rate was 95.8%, and a pseudoaneurysm (SIR Grade 2) developed in 1 patient, which was treated by a percutaneous injection of thrombin. No other access-related adverse events occurred, and the total adverse event rate was 4.2%.ConclusionsPlacement of sequential suture and plug VCDs using 1 Proglide and dual Exoseal is a safe and effective method and may be an option for access closure during PEVAR.  相似文献   

8.
PurposeTo determine if cone-beam CT and digital subtraction angiography analysis of pelvic arterial anatomy has predictive value for radiation exposure and technical success of prostatic artery embolization (PAE).Materials and MethodsThis prospective, nonrandomized, single-center study included 104 consecutive patients with lower urinary tract symptoms secondary to benign prostatic hyperplasia. Cone-beam CT was performed in 160/208 (76.9%) hemipelves to determine prostatic artery (PA) origin. Classification of pelvic arterial tortuosity was possible in 73/104 (70.2%) patients. Learning curves of 2 interventionalists who performed 86.5% of PAEs were analyzed.ResultsTortuosity of pelvic arteries was classified as mild in 25 (34.2%) patients median age 64 years, moderate in 40 (54.8%) patients median age 69 years, and severe in 8 (11.0%) patients median age 70 years (mild vs moderate, P = .002; mild vs severe, P = .019); median fluoroscopy times were 24, 36, and 46 minutes (P = .008, P = .023); median contrast volumes were 105, 122.5, and 142 mL (P = .029, P = .064); and bilateral PAE rates were 84.0%, 77.5%, and 62.5% (P = .437), respectively. PA origin from superior vesical artery was most frequent (27.5%) and showed higher dose area product (median 402.4 vs 218 Gy ∙ cm2, P = .033) and fluoroscopy time (median 42.5 vs 27 min, P = .01) compared with PA origin from obturator artery, which was least frequent. Interventionalist experience revealed significant impact on procedure times (median 159 vs 130 min, P = .006).ConclusionsTortuosity of pelvic arteries was more frequent in older patients and predicted worse technical outcomes of PAE. PA origin from obturator artery was associated with lower dose area product and fluoroscopy time, especially compared with PA origin from superior vesical artery. Interventionalist experience showed significant influence on technical outcome.  相似文献   

9.
PurposeTo compare the technical success of antegrade uteral stent (AUS) and retrograde ureteral stent (RUS) placements in patients with malignant ureteral obstruction (MUO) and to determine the predictors of technical failure of RUS.Materials and MethodsThis study retrospectively included 61 AUS placements (44 patients) performed under fluoroscopic guidance and 76 RUS placements (55 patients) performed under cystoscopic guidance in patients with MUO from January 2019 to December 2020. Technical success rates of the 2 techniques were compared using inverse probability of treatment weighting (IPTW) analysis. Logistic regression was used to identify predictive factors for technical failures.ResultsTechnical success was achieved in 98.4% of the AUS group and 47.4% of the RUS group. After stabilized IPTW, the technical success rate was higher in the AUS group than in the RUS group (adjusted risk difference, 49.4%; 95% confidence interval [CI], 35.4%–63.1%). The independent predictors for technical failure of the RUS procedure were age of ≥65 years (odds ratio [OR], 5.56; 95% CI, 1.73–21.27), ureteral orifice invasion (OR, 4.21; 95% CI, 1.46–13.46), and extrinsic cancer (OR, 15.58; 95% CI, 2.92–111.81).ConclusionsThe technical success rate of AUS placement was higher than that of RUS placement in patients with MUO. RUS failure was associated with age of ≥65 years, cancer with ureteral orifice invasion, and extrinsic ureteral obstruction.  相似文献   

10.
PurposeTo evaluate safety and effectiveness of percutaneous biliary endoscopy (PBE) performed on patients ineligible for surgery or endoscopic retrograde cholangiopancreatography.Materials and MethodsRetrospective review was conducted for all patients who underwent PBE at a single academic institution between June 2013 and February 2020; 39 patients underwent 58 choledochoscopy sessions, and 21 patients underwent 48 cholecystoscopy sessions. Choledochoscopy indications included stone removal (23 of 39 patients) or biliary stenosis evaluation (19 of 39 patients). Cholecystoscopy indications included calculous cholecystitis (18 of 21 patients) and symptomatic cholelithiasis (3 of 21 patients). Technical success, procedural and fluoroscopy times, and tube-free survival were assessed.ResultsFor all PBEs performed for stone clearance, using disposable endoscopes led to shorter mean ± SD procedural (128.7 minutes ± 56.2 vs 240.2 minutes ± 184.6; P < .01) and fluoroscopy times (10.7 minutes ± 7.9 vs 16.5 minutes ± 12.0; P = .01) than using reusable endoscopes. Increasing institutional experience was associated with reduced procedural time (β = −56.73; P < .001). Choledochoscopy technical success was 94.8% with 1 adverse event of bile duct perforation with bile leak requiring drainage. For patients with choledocholithiasis, biliary drains were removed in 14 (60.9%) patients, with a mean tube-free survival of 22.1 months ± 23.8. For cholecystoscopy, technical success was 93.8% with no adverse events. Cholecystostomy tubes were removed in 15 (71.4%) patients, with a mean tube-free survival of 7.5 months ± 8.8.ConclusionsThis study supports PBE as a safe and feasible option for nonsurgical patients or those with altered anatomy precluding endoscopic retrograde cholangiopancreatography. Moreover, PBE may result in tube-free survival.  相似文献   

11.
PurposeTo evaluate the safety and effectiveness of percutaneous image-guided thermal ablation (IGTA) for juxtacardiac lung tumors.Materials and MethodsThis bi-institutional retrospective cohort study included 23 consecutive patients (13 [57%] male; mean age, 55 years ± 18) with 30 juxtacardiac lung tumors located ≤10 mm from the pericardium treated in 28 IGTA sessions (25 sessions of cryoablation and 3 sessions of microwave ablation) between April 2008 and August 2022. The primary outcome was any adverse cardiac event within 90 days after ablation. Secondary outcomes included noncardiac adverse events, local tumor progression–free survival (LT-PFS), and the cumulative incidence of local tumor progression with death as a competing risk. Two tumors treated without curative intent or follow-up imaging were considered in the safety analysis but not in the progression analysis.ResultsThe median imaging follow-up duration was 22 months (interquartile range [IQR], 10–53 months). Primary technical success was achieved in 25 (89%) ablations. No adverse cardiac events attributable to IGTA occurred. One patient experienced a phrenic nerve injury. The median LT-PFS duration was 59 months (IQR, 32–73 months). At 1, 3, and 5 years, LT-PFS was 90% (95% CI, 78%–100%), 74% (CI, 53%–100%), and 45% (CI, 20%–97%), respectively, and the cumulative incidence of local tumor progression was 4.3% (CI, 0.29%–19%), 11% (CI, 1.6%–30%), and 26% (CI, 3.3%–58%), respectively.ConclusionsIGTA is safe and effective for lung tumors located ≤10 mm from the pericardium. No adverse cardiac events were not observed within 90 days after ablation.  相似文献   

12.
PurposeTo evaluate the efficacy and safety of placement of a modified microcoil for precise preoperative localization of solitary pulmonary nodules (SPNs) before video-assisted thoracoscopic surgery (VATS).Materials and MethodsThis prospective, single-arm, multicenter study included patients who underwent computed tomography (CT)-guided modified microcoil insertion prior to SPN resection by VATS between January 2018 and June 2018. The patient demographics, nodule characteristics, and histopathologic findings were recorded. The primary endpoints included efficacy and safety.ResultsA total of 96 patients (41 men and 55 women; mean age, 59.3 years ± 8.9) with 96 SPNs were eligible for enrolment in the study. The mean maximal transverse diameter of the nodules was 10.3 mm ± 5.2 (range, 8–20 mm). The mean time between CT-guided microcoil insertion and the start of the surgical procedure was 14.6 hours (range, 12–24 hours). The duration of the preoperative CT-guided microcoil localization procedure was 29 minutes ± 9 (range, 10–35 minutes), and the intraoperative fluoroscopy time was 0.7 minutes ± 0.7 (range, 0.5–3 minutes). The clinical success rate was 96.9% (93/96), and all nodules were successfully resected using VATS. One patient experienced asymptomatic pneumothorax, but there were no cases of pulmonary hemorrhage.ConclusionsSPN localization with the modified microcoil is feasible and safe. The modified microcoil can facilitate the thoracoscopic resection of SPNs.  相似文献   

13.
PurposeTo evaluate the safety and effectiveness of preoperative embolization with n-butyl cyanoacrylate (nBCA) performed for metastatic spinal cord compression (MSCC) in limiting blood loss (BL).Materials and MethodsIn this institutional review board–approved retrospective study, clinical records from 2017 to 2022 were reviewed. Twenty consecutive patients (11 men and 9 women; mean age, 65.8 years ± 10.0; range, 45–82 years) underwent 21 preoperative spine tumor embolizations with nBCA. Angiograms were used to calculate the percentage reduction in tumor vascularity, and relevant clinical data (levels studied and embolized, fluoroscopy time [FT], reference dose [RD], and Kerma area product [KAP]) and operative data (BL and operative time [OT]) were analyzed. Adverse events and outcomes were recorded.ResultsA median of 2 levels were embolized per procedure (range, 1–5) but 4.9 were studied (range, 1–10). After embolization, tumor blush was reduced by a median of 87.3% (range, 50%–90%). The mean FT was 41 minutes ± 15.4 (range, 16–67 minutes), the mean RD was 1,977.1 mGy ± 1,794.3 (range, 450.2–6,319 mGy), and the mean KAP was 180.5 Gy·cm2 ± 166.2 (range, 30.4–504 Gy·cm2). The adverse event rate was 1 (4.7%) of the 21 embolizations because a weakness of lower extremities related to swelling was observed. Surgery was performed at a mean of 1.4 days ± 1 (range, 1–5 days) after embolization. The mean surgical estimated BL was 432.5 mL ± 328.5 (range, 25–1,100 mL), and the mean OT was 210.1 minutes ± 97.4 (range, 57–489 minutes).ConclusionsPreoperative embolization of tumors resected for MSCC with nBCA is a safe procedure allowing for performance of surgery with acceptable BL.  相似文献   

14.
PurposeThis study evaluated the safety and efficacy of the JETi8 peripheral thrombectomy system in treating acute deep vein thrombosis (DVT).Materials and MethodsA retrospective study was conducted in 18 consecutive patients (mean age, 41 years old [range, 15-74 years old]; 5 men and 13 women). There were 21 instances of DVTs (9 iliofemoral, 10 axillosubclavian, and 2 portal), which were treated using the JETi8 thrombectomy device between November 2016 and July 2018. Thrombus was laced with recombinant tissue plasminogen activator (r-TPA) (9.3 mg, on average; range, 2–12 mg) in 17 procedures (81%) prior to thrombectomy. Technical success was defined as restoration of antegrade flow using the JETi8 with or without additional treatment of an underlying obstructive lesion. Procedural success was defined as technical success with or without the addition of overnight catheter-directed thrombolysis (CDT)ResultsMean procedure time was 83 minutes (range, 30–160 minutes), and mean thrombus reduction with the JETi8 alone was 92% (range, 60%–100%). Stent placement was required in 6 procedures (29%). Technical success using the JETi8 system alone was 76% (16 of 21 procedures), whereas 5 procedures (24%) required subsequent overnight CDT in the intensive care unit. Procedural success rate was 100% (20 of 20 procedures). Mean aspirated volume was 531 mL (range, 250–1,230 mL). The only adverse event was a subsegmental pulmonary embolism. Seven patients (33%) were discharged the same day. Recurrent thrombosis was observed in 5 patients (24%), of whom 3 were successfully treated with the JETi8 system.ConclusionsThe JETi8 system may be a safe and effective option for thrombectomy of acute DVT.  相似文献   

15.
PurposeTo investigate the safety and efficacy of an aqueous polyethylene glycol-based liquid embolic agent, Embrace Hydrogel Embolic System (HES), in the treatment of benign and malignant hypervascular tumors.Materials and MethodsA prospective, single-arm, multicenter study included 8 patients, 5 males and 3 females, with a median age of 58.5 years (30–85 years), who underwent embolization in 8 tumors between October 2019 and May 2020. Technical success was defined as successful delivery of HES to the index vessel, with disappearance of >90% of the targeted vascular enhancement or, for portal vein embolization, occlusion of the portal branches to the liver segments for future resection. The volume of HES administered, ease of use (5 point Likert scale), administration time, and adverse events (AEs) were recorded. Evaluation was performed at 7, 30, and 90 days via clinical assessment and blood testing, and follow-up imaging was performed at 30 days.ResultsEight patients were enrolled, and 10 embolizations were performed in 8 lesions. Tumors included hepatocellular carcinoma (n = 4), renal angiomyolipoma (n = 3), and intrahepatic cholangiocarcinoma (n = 1). Technical success was 100%, and the average ease of use was 3.3 ± 1.0 SD. The HES delivery time was 1–28 minutes (median, 16.5 minutes), and the HES volume injected was 0.4–4.0 mL (median, 1.3 mL). All patients reached 30-day follow-up with imaging, and 6 patients reached 90-day follow-up. There were 3 serious AEs in 2 patients that were unrelated to the embolic agent.ConclusionHES resulted in a 100% embolization technical success rate. The product ease of use was acceptable, and no target vessel recanalization was noted on follow-up imaging at 30 days.  相似文献   

16.
PurposeTo evaluate the feasibility and safety of robot-assisted transarterial chemoembolization (TACE) for hepatocellular carcinoma (HCC) using a new coaxial microcatheter driving controller-responder robot (CRR) system.Materials and MethodsA single-center prospective pilot study approved by the institutional review board was conducted using this CRR developed after analyzing 20 cases of conventional TACE procedures from May to October 2021. The study included 10 patients with HCCs: 5 (median age, 72 years; range, 64–73 years) underwent robot-assisted TACE, and 5 (median age, 57 years; range, 44–76 years) underwent conventional TACE for comparison. The feasibility and safety of robot-assisted TACE were evaluated by assessing the technical success, procedure time, adverse event rate, radiation dose, and early tumor response.ResultsThe entire TACE procedure was divided into 30 steps, of which 8 could be robotized. In robot-assisted TACE, technical success was achieved in 4 (80%) of 5 patients. No procedure-related adverse event was observed. The median procedure time was 56 minutes. At the 1-month follow-up, 3 of the 4 patients showed a complete or partial response after robot-assisted TACE. The median radiation doses for the operator and patients were 0.4 and 2,167.5 μSv in robot-assisted TACE and 53.2 and 2,989.7 μSv in conventional TACE, respectively.ConclusionsRobot-assisted TACE using a new CRR system was feasible and safe for the treatment of HCC and could remarkably decrease radiation exposure for the operators.  相似文献   

17.
PurposeThis study aimed to assess the safety and efficacy of percutaneous lithotripsy for gallstone eradication in patients with calculous cholecystitis with stones >1 cm.Materials and MethodsMulti-institutional institutional review board approved retrospective review of patients who presented with calculous cholecystitis and were not determined to be surgical candidates. All patients underwent percutaneous cholecystostomy tube placement for acute infection, which was later exchanged for a large sheath for ShockPulse (Olympus, Tokyo, Japan) lithotripsy and stone destruction. Review parameters included procedural technical and clinical data, including clinical presentation, mean length of hospital stay, and postintervention symptom reduction.ResultsTwelve patients (mean age, 74.6 years; range, 52–94 years; 6 men and 6 women) underwent large-bore sheath (24–30 F) cholangioscopy-assisted gallstone destruction via rigid lithotripsy. The size of the gallstones ranged from 1.2 to 4.0 cm. All patients had prior cholecystostomy access for a mean of 25 weeks before gallstone extraction to ensure tract maturation via transhepatic or transperitoneal access. The technical success rate in single-session stone removal was 100%, with no major procedure-related adverse events. All patients were symptom- and pain-free after the procedure. The mean procedure time was 111.5 minutes, and the mean fluoroscopy time was 19.2 minutes. The median length of hospital stay was 1 day after the procedure. The mean time from percutaneous lithotripsy to biliary tube removal was 35 days (range, 17–45 days).ConclusionsFluoroscopy-guided percutaneous rigid lithotripsy is a safe and effective procedure for gallstone destruction and extraction in patients who are poor surgical candidates with large lumen-occupying cholelithiasis.  相似文献   

18.
PurposeTo investigate the prevalence, clinical characteristics, and long-term prognosis of bronchial artery aneurysm (BAA) following bronchial artery embolization (BAE).Materials and MethodsThe medical records of consecutive patients who underwent bronchial artery angiography between August 2013 and December 2019 were retrospectively reviewed. Patients who were diagnosed with BAA during this period were included in this study. The prevalence, patients’ characteristics, symptoms, comorbidities, angiographic findings, and long-term prognosis following BAE were investigated.ResultsBAA was observed in 20 of 508 patients who underwent bronchial artery angiography (3.9%). The patients’ median age was 69 (interquartile range [IQR], 63.5–76.7) years. The main causes of BAA were cryptogenic, bronchiectasis or cystic fibrosis, and pulmonary aspergillosis. The median diameter of ruptured BAAs was significantly smaller than that of unruptured BAAs (5.4 mm [IQR, 4.8–7.3 mm] vs 9.0 mm [IQR, 7.2–13.9 mm], P = .009). All the patients were successfully treated with BAE, without major adverse events. The median follow-up period after BAE was 970 (IQR, 561–1,796) days. The BAA-related survival rate was 100% at 2 and 3 years after BAE, and the overall survival rate after BAE was 89.2% (95% confidence interval [CI] 89.0–89.3) at 2 years and 74.3% (95% CI 74.0–74.5) at 3 years. BAA-related adverse events and mortality did not occur during the follow-up period.ConclusionsBAA was observed in 3.9 % (20/508) of the patients who underwent bronchial artery angiography. All the patients with BAA were successfully treated with BAE. BAA rupture and consequent mortality did not occur during the follow-up period.  相似文献   

19.
PurposeTo determine whether hepatic hilar nerve block techniques reduce analgesic and sedation requirements during percutaneous image-guided thermal ablation of hepatic tumors.Materials and MethodsA single-center retrospective cohort analysis was performed of 177 patients (median age, 67 years; range, 33–86 years) who underwent percutaneous image-guided thermal ablation of liver tumors. All patients were treated utilizing local anesthetic and moderate sedation between November 2018 and November 2021 at a tertiary level hospital, with or without the administration of a hepatic hilar nerve block. Univariable and multivariable linear regression analyses were performed to determine the relationship between the administration of the hilar nerve block and fentanyl and midazolam dosages.ResultsA total of 114 (64%) patients received a hilar nerve block in addition to procedural sedation, and 63 (36%) patients received procedural sedation alone. There were no significant differences in the baseline demographic and tumor characteristics between the cohorts. The procedure duration was longer in the hilar block cohort than in the unblocked cohort (median, 95 vs 82 minutes; P = .0012). The technical success rate (98% in both the cohorts, P = .93) and adverse event rate (11% vs 3%, P = .14) were not significantly different between the cohorts. After adjusting for patient and tumor characteristics, ablation modality, and procedure and ablation durations, hilar nerve blocks were associated with lower fentanyl (?18.4%, P = .0045) and midazolam (?22.7%, P = .0007) dosages.ConclusionsHepatic hilar nerve blocks significantly decrease the fentanyl and midazolam requirements during thermal ablation of hepatic tumors, without a significant change in the technical success or adverse event rates.  相似文献   

20.
PurposeTo retrospectively evaluate the relief of pain after percutaneous image-guided cryoablation of symptomatic extraperitoneal endometriosis (EE).Material and MethodsFrom 2017 to 2022, cryoablation of EE was performed at a single institution on a total of 47 lesions in 42 consecutive patients (median age, 37 years; interquartile range [IQR], 33–39.5 years). Patient and procedural characteristics were reviewed retrospectively. Tolerance and outcomes in terms of pain and patient satisfaction were evaluated.ResultsThe median follow-up duration was 13.5 months (IQR, 1.1–37.7 months) after cryoablation. The median pain-free survival rate was 93.8% (95% confidence interval [CI], 77.3–98.4) at 6 months and 82.7% (95% CI, 58.8–93.5) after 12 months. Pain decreased from a median of 8/10 (IQR, 7–9) on the visual analog scale to 0/10 (IQR, 0–1) at the last follow-up (P < .0001). The median Patient Global Impression of Change score recorded at the last follow-up was 1/7 (IQR, 1–2). The efficacy rate of cryoablation to avoid secondary surgery was 92.8% (39/42) per patient and 93.6% (44/47) per nodule treated. Four patients (9.5%, 4/42) experienced an adverse event in the days following the procedure, and 1 patient (2%) experienced a severe adverse event.ConclusionsPercutaneous cryoablation is safe and effective in significantly reducing pain and obtaining local control of EE.  相似文献   