首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
From 1978 to 1988, 697 patients with a mean age of 48 +/- 11 years (range 5 to 75 years) received a Sorin tilting-disc prosthesis; 358 had had aortic valve replacement, 247 mitral valve replacement, and 92 mitral and aortic valve replacement. Operative mortality rates were 7.8%, 11.3%, and 10.8%, respectively, in the three groups. Cumulative duration of follow-up is 1650 patient-years for aortic valve replacement (maximum follow-up 11.4 years), 963 patient-years for mitral valve replacement (maximum follow-up 9.9 years) and 328 patient-years for mitral and aortic valve replacement (maximum follow-up 9.4 years). Actuarial survival at 9 years is 72% +/- 4% after mitral valve replacement, 70% +/- 3% after aortic valve replacement, and 50% +/- 12% after mitral and aortic valve replacement, and actuarial freedom from valve-related deaths is 97% +/- 2% after mitral valve replacement, 92% +/- 2% after aortic valve replacement, and 62% +/- 15% after mitral and aortic valve replacement. Thromboembolic events occurred in 21 patients with aortic valve replacement (1.3% +/- 0.2%/pt-yr), in 12 with mitral valve replacement (1.2% +/- 0.3% pt-yr), and in seven with mitral and aortic valve replacement (2.1% +/- 0.8%), with one case of prosthetic thrombosis in each group; actuarial freedom from thromboembolism at 9 years is 92% +/- 3% after mitral valve replacement, 91% +/- 3% after aortic valve replacement, and 74% +/- 16% after mitral and aortic valve replacement. Anticoagulant-related hemorrhage was observed in 15 patients after aortic valve replacement (0.9% +/- 0.2%/pt-yr), in 9 after mitral valve replacement (0.9% +/- 0.3%/pt-yr), and in 6 with mitral and aortic valve replacement (0.9% +/- 0.5%/pt-yr); actuarial freedom from this complication at 9 years is 94% +/- 2% after aortic valve replacement, 91% +/- 4% after mitral valve replacement, and 68% +/- 16% after mitral and aortic valve replacement. Actuarial freedom from reoperation at 9 years is 97% +/- 2% after mitral and aortic valve replacement, 92% +/- 4% after mitral valve replacement, and 89% +/- 3% after aortic valve replacement, with no cases of mechanical fracture. The Sorin valve has shown a satisfactory long-term overall performance, comparable with other mechanical prostheses, and an excellent durability that renders it a reliable heart valve substitute for the mitral and aortic positions.  相似文献   

2.
From May 1983 to July 1987 a total of 153 Hancock II porcine bioprostheses have been implanted in 130 patients with a mean age of 59 +/- 8 years (range 29 to 76 years). Mitral valve replacement was performed in 72 patients, aortic valve replacement in 35, and mitral-aortic valve replacement in 23. Cumulative follow-up of 121 survivors is 223 patient-years and 100% complete (range 0.4 to 4.5 years). The actuarial survival rate at 4 years is 88% +/- 8% for mitral, 86% +/- 7.8% for aortic, and 84% +/- 8% for mitral-aortic valve replacement. Minor thomboembolism occurred in two patients (0.9% +/- 0.6%/pt-yr) with an actuarial freedom from emboli at 4 years of 100% for mitral, 96% +/- 3.7% for aortic, and 91% +/- 8.6% for mitral-aortic valve replacement. Anticoagulant-related hemorrhage occurred in 10 patients (4.4% +/- 1.4%/pt-yr) with an actuarial freedom at 4 years of 90% +/- 4.8% for mitral, 89% +/- 5.8% for aortic, and 84% +/- 10.6% for mitral-aortic valve replacement. Failure of the porcine bioprosthesis was observed in three patients with an actuarial freedom at 4 years of 96% +/- 3.6% for aortic, 91% +/- 8% for mitral, and 91% +/- 8.6% for mitral-aortic valve replacement. Actuarial freedom from all porcine bioprosthesis-related complications at 4 years is 85.7% +/- 6.6% for aortic, 79% +/- 9% for mitral, and 70% +/- 13% for mitral-aortic valve replacement. No instances of primary tissue failure occurred.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

3.
The long-term survival following valve replacement with Carpentier-Edwards or Hancock bioprostheses was compared between the two valve models and between the two groups totaling 407 patients who were discharged after valve replacement beginning in 1974. The two groups of patients were treated in a nonrandomized fashion. The actuarial survival for 299 patients with Carpentier-Edwards valves was 94 +/- 1.5% (+/- standard error) and 93 +/- 1.7% after 5 and 8 years of follow-up, respectively. Comparable figures for 108 patients undergoing valve replacement with Hancock valves were 89 +/- 3.0% and 83 +/- 3.7%, respectively (p = not significant [NS]). The probability of freedom from death and valve removal after 5 and 8 years of follow-up was 91 +/- 1.8% and 79 +/- 4.6%, respectively, with the Carpentier-Edwards valve and 84 +/- 3.5% and 75 +/- 4.3%, respectively, with the Hancock valve (p = NS). An accelerated rate of attrition for both valves was observed in the mitral position. There were no significant differences in actuarial survival between the two valves in the mitral or the aortic position or in the incidence of major valve-related complications.  相似文献   

4.
Results of reoperation for primary tissue failure of porcine bioprostheses were evaluated in 574 patients discharged from the hospital from 1970 to 1981. A total of 413 had undergone isolated mitral valve replacement and 161 isolated aortic valve replacement. Through March, 1984, 88 patients (15%) had required reoperation: 59 had undergone mitral and 29, aortic valve replacement. Primary tissue failure was the main cause of bioprosthetic dysfunction; it occurred in 64 patients (46 mitral and 18 aortic) at a mean postoperative interval of 93 +/- 4 months (range 34 to 158). During the same period, 11 patients required reoperation for bioprosthetic endocarditis, 11 for paravalvular leak, and two for thrombosis. These patients are not included in this review. Reoperation for primary tissue failure was performed after a mean interval of 72 +/- 6 months (range 38 to 158) for patients with aortic bioprostheses and after 101 +/- 5 months (range 34 to 153) for those with mitral bioprostheses (p less than 0.05). Overall mortality at reoperation was 12.5%: 11% for the mitral group and 16% for the aortic group. In 62 patients (45 mitral and 17 aortic) primary tissue failure was caused by calcification of the cusps, associated with severe fibrous tissue overgrowth in seven. Bioprosthetic failure was caused by an intracuspal hematoma in one patient with mitral valve replacement and by lipid infiltration of the cusps in one patient with aortic valve replacement. Actuarial freedom from bioprosthetic primary tissue failure at 12 years is 61% +/- 5% for the mitral group and 69% +/- 7% for the aortic group. On the basis of our long-term follow-up of patients after mitral or aortic replacement with a porcine bioprosthesis, we conclude: primary tissue failure is the most frequent indication for reoperation in patients with a porcine bioprosthesis; calcification of the cusp tissue is the leading cause of primary tissue failure; reoperation for primary tissue failure may be a major concern, although mortality for elective cases is low; and the limited durability of porcine bioprostheses suggests their use be restricted to selected patients.  相似文献   

5.
OBJECTIVES: The clinical results of Carpentier-Edwards standard bioprosthesis have been extensively studied for valvular heart surgery in America and Europe. However, the data of long-term performance of Carpentier-Edwards standard porcine valve in areas with a high prevalence of rheumatic heart disease are still lacking. In this study, we assessed the clinical performance of Carpentier-Edwards standard porcine bioprostheses in a patient group with high prevalence of rheumatic heart disease. METHODS: A total of 872 patients underwent valvular heart surgery with Carpentier-Edwards standard porcine bioprostheses replacement between 1975 and 1999 and the results were analyzed. Rheumatic etiology counts for 95% of the patients. Mean age of operation was 40 +/- 14 years (mitral valve), 43 +/- 19 years (aortic valve), and 45 +/- 13 years (double valve). Follow-up was 95.6% complete and continued up to 24 years (total 7017 patient-years) with mean of 8.9 +/- 5.1 years. RESULTS: The operative mortality rate was 5.85%. Actuarial patient survival rates after discharge at 5, 10, 15, and 20 years were 92.5%, 83.8%, 72.3%, and 35.8%, respectively. A total of 442 cases received reoperation due to failure of bioprostheses. The mean duration to valve failure is 12.2 +/- 0.4 years. Actuarial estimate of freedom from structural valvular failure at 5, 10, 15, and 20 years were 96.3%, 63.7%, 24.4%, and 7.7%, respectively. CONCLUSION: The long-term result of Carpentier-Edwards standard bioprostheses in the present patient group is satisfactory. However, freedom from valve failure is lower than that of Western series. Younger age at operation and higher prevalence of rheumatic etiology in this area are possible causes.  相似文献   

6.
Valve-related morbidity and mortality after heart valve replacement with the Hancock I porcine bioprosthesis has been retrospectively analyzed. From June 1974 through December 1976, 253 Hancock I bioprostheses (150 mitral and 103 aortic) were inserted in 220 selected patients who survived the operation and had follow-up until June 1989 (mean follow-up 13.5 years, with an accumulative follow-up of 2956.4 patient-years). One hundred seventeen patients had mitral valve replacement, 70 had aortic valve replacement, and 33 had combined mitral and aortic valve replacement. There were 27 thromboembolic events. The probability of being free from thromboembolism at 14 years was 81.0% +/- 7.4% for the mitral valve replacement group, 85.4% +/- 6.7% for the aortic group, and 67.1% +/- 18.4% for the mitral-aortic group. Fifteen episodes of prosthetic valve endocarditis occurred. There were 10 instances of nonstructural dysfunction (paravalvular leaks) in seven mitral valves (4.6%) and in three aortic valves (2.9%). One hundred twenty-two bioprostheses in 106 patients resulted in structural deterioration. The probability of freedom from structural deterioration at 14 years was 37.2% +/- 3.9% for the mitral group, 43.9% +/- 7.1% for the aortic group, and 30.1% +/- 8.9% for the mitral-aortic group. The logistic regression analysis between age at the time of operation and bioprosthetic life (structural deterioration-free period) demonstrates a linear regression curve (r = 0.53). There were 56 late deaths (27 patients died at reoperation). The actuarial survival rate (including hospital mortality) at 14 years was 57.2% +/- 5.4% for the entire series, with no statistically significant difference between groups. The probability of remaining free from valve-related morbidity and mortality at 14 years was 16.7% +/- 4.8% for the mitral group, 20.8% +/- 6.2% for the aortic group, and 14.0% +/- 7.0% for the mitral-aortic group. The long-term results of this series show that the clinical performance of the Hancock I porcine valve appears satisfactory during the first 6 years. The behavior of this bioprosthesis at 14 years' follow-up changes drastically, because only a minor group of patients is free from valve-related complications, justifying the restriction of its use for selected patients.  相似文献   

7.
Clinical results with porcine bioprostheses were reviewed for 990 patients who underwent heart valve replacement from January, 1974, to December, 1980. Eight hundred and seventy-four Hancock, 283 Carpentier-Edwards, and 10 Liotta bioprostheses were used. In 23 patients, 26 mechanical prostheses were implanted as well. Overall operative mortality was 60 out of 990 (6.06%): 30 out of 506 (5.9%) for mitral valve replacement (MVR), 13 out of 287 (4.5%) for aortic valve replacement (AVR), 1 out of 4 (25%) for tricuspid valve replacement, 0 out of 2 for pulmonary valve replacement, and 16 out of 191 (8.4%) for multiple valve replacement. Cumulative follow-up covered 1,793 patient-years. (Actuarial survival at 7 years was 76.6 +/- 3% for MVR. At 6 years, it was 83.2 +/- 2.8% for AVR and 55 +/- 13.5% for multiple valve replacement.) Prosthesis-related survival at 7 years was 91.7 +/- 1.9% for MVR, and at 6 years, it was 96.6 +/- 1.5% for AVR and 95.1 +/- 2.2% for multiple valve replacement. Bioprosthesis survival, considering deaths or complications that led to reoperation as final events, was 84.2 +/- 3.7% at 7 years for mitral valves and 87.7 +/- 3.8% at 6 years for aortic valves. Emboli per 100 patient-years numbered 3.2 for MVR, 0.5 for AVR, and 1.6 for multiple valve replacement. Twenty-seven patients underwent reoperation, 12 for perivalvular leak, 5 for endocarditis, 6 for valve thrombosis, and 4 for primary tissue failure (linearized rates of 0.7, 0.3, 0.3, and 0.2% per patient-year, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

8.
Isolated aortic (n = 857) or mitral (n = 793) valve replacement with a porcine bioprosthesis was performed in 1650 patients between 1971 and 1980. Follow-up (total = 12,012 patient-years) extended to more than 15 years and was 96% complete. Patient age ranged from 16 to 87 years; mean age was 59 +/- 11 years (+/- 1 standard deviation) for the aortic valve replacement cohort and 56 +/- 12 years for the mitral valve replacement cohort. The operative mortality rates were 5% +/- 1% (+/- 70% confidence limits) and 8% +/- 1%, respectively, for the aortic and mitral subgroups. Estimated freedom from structural valve deterioration (+/- 1 standard error of the mean) after 10 and 15 years was significantly higher for the aortic than for the mitral valve replacement subgroup (85% +/- 0.4% and 63% +/- 3% versus 78% +/- 2% and 45% +/- 3%, respectively, p = 0.001). Reoperation-free actuarial estimates were also significantly greater for the aortic valve replacement cohort: 83% +/- 2% and 57% +/- 3% versus 78% +/- 2% and 43% +/- 3% for mitral valve replacement at 10 and 15 years, respectively. The mortality rate for reoperative aortic valve replacement was 11% +/- 1%; it was 8% +/- 1% for reoperative mitral valve replacement. Importantly, the estimates of freedom from valve-related death (including sudden, unexplained deaths) were relatively high at 10 and 15 years: 78% +/- 2% and 69% +/- 3% in the aortic cohort and 74% +/- 2% and 63% +/- 3% in the mitral cohort (p = not significant). Excluding sudden, unexplained deaths, these estimates were 81% +/- 3% (aortic) and 73% +/- 4% (mitral) at 15 years. Thromboembolism-free rates were 84% +/- 3% (aortic) and 78% +/- 6% (mitral) at 15 years, and freedom from anticoagulant-related hemorrhage was 96% +/- 1% and 89% +/- 2%, respectively. At the time of current follow-up, 13% of patients having aortic valve replacement and 50% of patients having mitral valve replacement were receiving warfarin sodium. The hazard functions for thromboembolism and prosthetic valve endocarditis were constant and remained less than 1%/pt-yr over the entire follow-up period.(ABSTRACT TRUNCATED AT 400 WORDS)  相似文献   

9.
From February 1975 through October 1981, 256 Hancock porcine bioprostheses (Johnson & Johnson Cardiovascular, King of Prussia, Pa.) (60 aortic, 169 mitral, and 27 pulmonary/tricuspid position) were implanted in 220 patients (104 male and 116 female, aged 9 to 67 years; mean 43.3) at Kyushu University Hospital in Japan. The procedures include 41 aortic valve replacements, 121 mitral valve replacements, 4 pulmonary valve replacements, 6 tricuspid valve replacements, and 48 combined valve replacements (31 aortic plus mitral, 13 mitral plus tricuspid, and 4 aortic plus mitral plus tricuspid). Hospital mortality was 6.4%. Follow-up was 98% during 8 to 14 (mean 10.5) years. Cumulative follow-up was 1836 patient-years and 2078 valve-years. At 10 years the overall actuarial survival rate, including hospital morality, was 70% +/- 3%, and freedom from valve-related mortality with sudden death was 87% +/- 3%. More than half of the current survivors required no anticoagulant therapy. Freedom from thromboembolism or anticoagulant-related hemorrhage (or both) and prosthetic valve endocarditis was common. Freedom from structural valve failure and reoperation declined more than 9 years after replacement of left-sided heart valves but not after replacement of right-sided heart valves. Sixty-seven patients underwent 68 repeat operations, and there were four deaths (5.9%). The rate of freedom from overall valve-related complications at 10 years was 62% +/- 8% for aortic valve replacement, 53% +/- 5% for mitral valve replacement, 80% +/- 13% for pulmonary/tricuspid valve replacement, and 42% +/- 9% for combined valve replacement. There was a significant difference between pulmonary/tricuspid valve replacement and combined valve replacement (p less than 0.05). The Hancock bioprosthesis is suitable for the replacement of valves in the right side of the heart but not for combined valve replacement.  相似文献   

10.
One hundred and ninety-four patients underwent valve replacements with the glutaraldehyde-preserved porcine bioprostheses (133 Hancock valves, 39 Angell-Shiley valves, 22 Carpentier-Edwards valves and 3 other valves) from 1974 through 1979. There were 105 women and 89 men, whose age ranged 18 to 62 (mean 38.8) years. One hundred and eighty-two patients had mitral bioprosthetic valve replacement (BVR)s, of which 52 had combined aortic mechanical valve replacements, 8 had aortic BVR's, 3 had tricuspid BVR's and 3 had multi-BVR's. Operative mortality was 10.8%. Only one patient was lost to follow-up. Cumulative duration of follow-up is 1421 patient-years. Linearized rate of anticoagulant related hemorrhage, thromboembolism (TE), prosthetic valve endocarditis (PVE), primary tissue failure (PTF) and valve dysfunction (VD) were 0.07, 1.62, 0.49, 2.74 and 3.66% per patient-year. Actuarial freedom from TE, PVE, PTF and VD were 87.0 +/- 2.7%, 95.6 +/- 1.5%, 65.2 +/- 4.9% and 56.9 +/- 5.6% at 13 years. Actuarial survival rate was 67.4 +/- 4.0% at 13 years. Long term follow-up after valve replacement with porcine bioprosthetic valve confirms low thrombogenicity. But primary tissue failure was the chief cause of valve dysfunction and represent a major problem. At this time, we are going to use porcine bioprosthetic valve in the selected patients, that is in the situations in which anticoagulation is contraindicated.  相似文献   

11.
Mechanical valve replacement in children and teenagers   总被引:1,自引:0,他引:1  
A previous study from this unit showed that only 19% of children with mitral bioprostheses were free from complications after 7 years and prompted us to review the performance of new-generation mechanical prostheses implanted in the same population group. In a 5-year period (1980-1985), 352 patients 20 years old and younger (mean age 15.3 +/- 4 years) with rheumatic valvular disease had 177 mitral, 62 aortic and 113 double (mitral + aortic) valve replacements with Medtronic-Hall or St. Jude prostheses. The overall early mortality was 6.3%. All survivors, followed up for a total of 1171 patient-years, received oral anticoagulation. The late mortality for mitral, aortic and double valve replacement was 4.1% per patient-year, 4.3% per patient-year and 8.0% per patient-year, respectively (P less than 0.05), and was valve-related in 46% of the cases. Twenty-nine patients, all but 2 in the mitral and double valve replacement groups, were reoperated upon (2.5% per patient-year), mainly for infective endocarditis (34%), for prosthetic thrombosis (33%) and for bland periprosthetic leak (31%). The incidence of thrombotic obstruction was 1.1% per patient-year: mitral valve replacement, 1.0% per patient-year; aortic valve replacement 0.5% per patient-year; and double valve replacement, 1.7% per patient-year; P less than 0.05) and was fatal in 33% of the cases. Major systemic thromboembolism occurred at the rate of 1.4% per patient-year, similar in the three groups. The incidence of prosthetic endocarditis was 0.9% per patient-year.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

12.
From 1976 to 1988, 1,593 patients underwent valve replacement with a porcine (878 patients) or a pericardial bioprosthesis (715 patients). There were 701 aortic, 678 mitral, and 214 multiple-valve replacements. Follow-up was obtained for 1,559 patients (98%). Early mortality was 9% (79 patients) in the porcine valve group and 5% (37 patients) among patients with a pericardial valve (p less than 0.01). Late survival after replacement with porcine valves was 80% +/- 1% and 62% +/- 3% at 5 and 10 years, respectively. With pericardial valves, 5-year survival was 79% +/- 2%. Among valve-related complications, rates of freedom from thromboembolism, endocarditis, and hemorrhage after 6 years were similar for both valve groups. Freedom from reoperation at 6 years was also similar after aortic (96% versus 91%) or multiple-valve replacement (95% versus 88%). However, for mitral valve replacement, freedom from reoperation was significantly better with porcine valves than with pericardial valves at 6 years (92% versus 68%; p less than 0.001). This difference was mainly due to the Ionescu-Shiley valve, which accounted for 83% of primary tissue failures among pericardial bioprostheses implanted in the mitral position (10/12 patients). After 6 years, freedom from primary tissue failure of mitral valves was 92% +/- 2% with porcine and 70% +/- 11% with pericardial bioprostheses (p less than 0.0001). The degree of clinical improvement among survivors was similar with both valve types. Thus, in the aortic position, pericardial valves compare with porcine valves up to 6 years, whereas in the mitral position, the durability of the former is significantly less, mainly because of the suboptimal performance of the Ionescu-Shiley pericardial bioprosthesis.  相似文献   

13.
A total of 589 porcine bioprostheses were implanted in 509 patients from January, 1976, through December, 1983. Of the valves implanted, 390 were Hancock and 199 were Carpentier-Edwards. A total of 1,633 patient-years was accrued, with a mean follow-up of 38 months per patient. Two hundred eight patients had aortic valve replacement, 209 had mitral valve replacement, and 79 had multiple valve replacements, of which 46 were aortic and mitral replacements. The mortality for isolated aortic valve replacement was 5.8%; for isolated mitral replacement, 8.6%, and for all patients, 10.9%. Late mortality was 3.9% per patient-year. The actuarial survival rate at 5 years was 79% for aortic, 68% for mitral, and 76% for aortic-mitral valve replacement. There were 12 thromboembolic events (0.73% per patient-year). Two episodes occurred in patients with an aortic bioprosthesis, nine in patients with a porcine mitral valve, and one in a patient with mitral and tricuspid bioprosthetic valves. The probability of remaining free of thromboembolism at 5 years was 99% for the group having aortic valve replacement, 93% for those having mitral replacement, and 100% for the group having aortic-mitral valve replacements. Thirteen episodes of endocarditis occurred (0.8% per patient-year). Seven of the 13 patients died as a direct result of endocarditis. The probability of remaining free of prosthetic endocarditis at 5 years was 97% for the aortic valve replacement group, 95% for the mitral group, and 97% for the aortic-mitral group. There were 20 instances of xenograft failure (1.2% per patient-year). The probability of remaining free of valve failure at 5 years was 96% for the aortic valve replacement group, 93% for the mitral group, and 93% for the aortic-mitral replacement group. Primary tissue failure of a prosthesis occurred in seven patients, all with Hancock valves (0.43% per patient-year). As yet there has been no primary tissue failure of the Carpentier-Edwards prosthesis. There also appears to be a lower incidence of thromboembolism (Edwards, 0.3% per patient-year; Hancock, 0.8% per patient-year) and endocarditis (Edwards, 0.6% per patient-year; Hancock, 1.0% per patient-year). The low incidence of complications with the porcine bioprosthetic valve, especially the Carpentier-Edwards, encourages us to recommend its continued use, especially in situations in which anticoagulation is contraindicated.  相似文献   

14.
The Carpentier-Edwards porcine valve bioprosthesis was implanted in 299 patients (325 prostheses) from April 1976 to April 1982. The series consisted of aortic valve replacement in 150 patients, mitral valve replacement in 120, multiple valve replacement in 26, pulmonary valve replacement in 2 and tricuspid valve replacement in 1 patient. The postoperative follow-up was 100% complete. The total accumulated follow-up was 1956 patient-years. The early mortality was 6.4% (20 patients) and the late mortality was 22% (62 patients). Valve-related mortality was seen in 8 patients (2.7%): 1 paravalvular leak during the 1st 30 postoperative days and 7 late mortalities (1 endocarditis, 2 paravalvular leaks and 4 deaths during reoperation). Three operative deaths (1.5%) occurred. The overall patient survival including operative deaths was 78.5% +/- 5% at 5 years and 66% +/- 4% at 10 years. The incidence of the different complications were: thromboembolism in 5 patients (1.7%) with a risk of 0.3%, haemorrhage in 1 (0.3%) with a risk of 0.05%, endocarditis in 2 (0.7%) with a risk of 0.1%, and paravalvular leak in 11 patients (3.7%) with a risk of 0.6%. There was a high incidence of tissue failure during the last 6 years which occurred in 54 patients (18%) with a risk of 2.7%. Sixty-seven patients (22.5%) were reoperated upon during the 11 years with an annual risk of 3.4% and the main cause of reoperation was primary tissue failure. The Carpentier-Edwards biological valve was shown to be efficient during the first 5 years of implantation after which the incidence of tissue failure increased.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

15.
Because little information is available regarding the clinical performance of the Hancock porcine bioprosthesis (Johnson & Johnson Cardiovascular, King of Prussia, Pa.) implanted in the tricuspid position, we reviewed the long-term follow-up of patients who had tricuspid valve replacement with this device. From March 1970 to December 1983, 45 patients had tricuspid valve replacement, either isolated (seven patients) or combined with replacement of other valves (38 patients) by means of a standard, glutaraldehyde-preserved Hancock porcine bioprosthesis. Follow-up ranged from 0.2 to 14.7 years (mean, 7.6 +/- 3.6 years) and was complete. The late mortality rate was 6.6% +/- 1.6%/pt-yr and the actuarial survival rate at 14 years was 23% +/- 9%. Reoperation because of structural deterioration of the tricuspid, the mitral, or both bioprostheses was performed in nine patients (3.7% +/- 1.2%/pt-yr) from 40 to 177 months (mean, 112 +/- 43 months) and resulted in no deaths. Actuarial freedom from structural deterioration of a Hancock tricuspid porcine bioprosthesis at 14 years is 68% +/- 13%. Morphologic examination of explanted porcine bioprostheses showed that those implanted in the tricuspid position had lower degrees of calcification and less severe structural changes than those simultaneously explanted from the mitral position. We conclude that the Hancock porcine bioprosthesis has an acceptable long-term durability and satisfactory performance after tricuspid valve replacement, and we continue to favor its use in the tricuspid position even in association with mechanical prostheses in the left side of the heart.  相似文献   

16.
Primary tissue failure (structural valve deterioration) has been documented as the most prominent complication of porcine bioprostheses. The influence of age on primary tissue failure has received limited consideration. From 1975 to 1986, 1,301 Carpentier-Edwards standard porcine bioprostheses were implanted in 1,183 patients in 1,201 operations. Of the total number of prostheses, 97.7% were implanted prior to 1983. The mean follow-up was 5.6 years and was 97.5% complete. Primary tissue failure was identified in 96 patients (98 operations) at reoperation (95) or autopsy (3). One hundred four (104) prostheses were involved. Thirty-one failed after aortic valve replacement (AVR), 49 after mitral valve replacement (MVR), and 24 after multiple-valve replacement (18 patients). There were 47 male and 49 female patients. The mean age at implantation was 47 years (range, 8 to 72 years). The mean implantation time was 74.0 months. The freedom from primary tissue failure at 10 years is 77.0 +/- 2.9% overall; for AVR, 83.1 +/- 3.7%; for MVR, 72.1 +/- 4.9%; and for multiple-valve replacement, 65.5 +/- 7.8%. The freedom from deterioration for patients less than 20 years of age is significantly less than that for other age groups. The freedom from deterioration increased by decades; the greatest freedom was noted in patients 70 to 80 years old and 80 years old or older. The freedom from deterioration at 10 years for patients less than 30 years of age is 26.8 +/- 17.2%; 30 to 59 years, 77.4 +/- 3.0%; and 60 years and older, 83.1 +/- 4.2%.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

17.
Long-term evaluation of patients undergoing combined mitral and aortic valve replacement (MVR + AVR) with a porcine bioprosthesis provides the opportunity for a direct comparison of the durability of the mitral versus the aortic porcine bioprosthesis in the same patient. From 1970 to 1983, 71 patients underwent MVR + AVR with Hancock porcine bioprostheses. There were 46 men an 25 women ranging in age from 21 to 64 years (mean, 47.5 +/- 5 years). Sixteen patients (22.5%) died at operation. The survivors were followed from 0.2 to 11.5 years (mean, 5.7 +/- 3 years). Duration of follow-up was 313 patient-years and was 100% complete. Overall late mortality was 6.7 +/- 1.4% per patient-year (linearized incidence), and actuarial survival was 54.2 +/- 8% at 11 years. Endocarditis occurred in 4 patients (linearized incidence of 1.3 +/- 0.6% per patient-year); thromboembolic events were sustained by 4 patients (linearized incidence of 1.3 +/- 0.6% per patient-year); the event was fatal in 1 patient. Actuarial freedom from thromboembolism was 90 +/- 4.8% at 11 years. Reoperation for primary tissue failure was performed in 11 patients (linearized incidence of 3.5 +/- 1% per patient-year) with no deaths; in 7 patients both bioprostheses were explanted, and in 4, only the mitral bioprosthesis was replaced. The durability of explanted aortic and mitral porcine bioprostheses was not significantly different, and the evaluation of seven pairs of explanted aortic and mitral bioprostheses showed similar amounts of calcification. Actuarial freedom from reoperation because of primary tissue failure was 44.6 +/- 13.7% at 11 years.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

18.
The Carpentier-Edwards standard porcine bioprosthesis was implanted in 1190 patients (1201 operations, 1303 valves) between January 1975 and June 1986; most implants were before 1982. The mean age of the patients was 57.2 years (range 8 to 85 years). The early mortality was 7.6% (aortic valve replacement 5.1%, mitral valve replacement 8.8%, and multiple valve replacement 15.3%). Late mortality was 3.9% per patient-year (aortic valve replacement 3.6%, mitral valve replacement 4.2%, and multiple valve replacement 3.8%). The total cumulative follow-up period was 6737 years. Thromboembolism was 1.5% per patient-year (fatal 0.4% per patient-year) (minor 0.6%, major 0.9%); antithromboembolic therapy-related hemorrhage was 0.5% (fatal 0.1%); prosthetic valve endocarditis was 0.6% (fatal 0.2%); nonstructural dysfunction was 0.5% (fatal 0.2%); and structural valve deterioration and/or primary tissue failure was 1.5% per patient-year (fatal, 0.2% per patient-year). Thromboembolism and structural valve deterioration were the significant complications, structural valve deterioration occurring primarily between the sixth and 10th year of evaluation. The overall patient survival was 65.0% for aortic valve replacement and 54.8% for mitral valve replacement (p less than 0.05) at 10 years. The patients were classified as 92.9% New York Heart Association functional classes III and IV preoperatively and 92.3% classes I and II postoperatively. Freedom at 10 years from thromboembolism was 84.3% for aortic valve replacement and 76.5% for mitral valve replacement (p = 0.05); structural valve deterioration was 78.6% for aortic valve replacement and 71.6% for mitral valve replacement (p less than 0.05); reoperation was 74.4% for aortic valve replacement and 67.1% for mitral valve replacement (p less than 0.05). Freedom from all valve-related complications at 10 years was 58.9% for aortic valve replacement and 46.8% for mitral valve replacement (p less than 0.05); valve-related mortality was 89.5% for aortic valve replacement and 82.6% for mitral valve replacement (p = not significant); mortality and reoperation was 58.9% for aortic valve replacement and 46.8% for mitral valve replacement (p less than 0.05); mortality and residual morbidity (treatment failure) was 87.2% for aortic valve replacement and 75.1% for mitral valve replacement (p = not significant); mortality, residual morbidity, and reoperation were 66.3% for aortic valve replacement and 54.9% for mitral valve replacement (p less than 0.05). The standard Carpentier-Edwards porcine bioprosthesis has provided satisfactory clinical performance and has afforded patients excellent quality of life.  相似文献   

19.
Carpentier-Edwards bioprostheses were implanted in 605 patients, 509 of whom had a single valve replacement, and 96 of whom had a multiple valve replacement. There were 54 early deaths (8.9%) and 26 late deaths (4.3%). The five-year actuarial survival was 87% for aortic valve replacement, 83% for mitral valve replacement, and 81% for multiple valve replacement. Of the 525 survivors, all but 3 were followed for a total of 964 patient-years; 354 patients (68%) remained asymptomatic, and 95 patients (18%) were improved. The incidences of thromboembolism, endocarditis, and reoperation due to primary tissue failure of the bioprosthesis were 2.0, 1.3, and 0.1% per patient-year, respectively. The actuarial probability of being free of all valve-related complications was 93% after five years. Satisfactory hemodynamic performance of the bioprosthesis was demonstrated by postoperative studies done in 70 patients. Thus, the Carpentier-Edwards porcine valve provides good clinical improvement, with a low incidence of valve-related complications and tissue failure at five years postoperatively.  相似文献   

20.
Between November 1977 and October 1980, 54 patients underwent valve replacements with porcine bioprostheses at Hyogo Kenritsu Amagasaki Hospital. The late complications and the long term durability of 53 porcine bioprostheses were documented in 48 patients after discharge (34 mitral, 7 aortic, 2 tricuspid, and 5 multiple, consisting of 38 Hancock, 15 Carpentier-Edwards prostheses). Cumulative duration of follow-up is 420 patient-years. The valve related late mortality was 0.52%/patient-years. There were 6 thromboembolic events (1.6% patient-years), only 1 episode of endocarditis (0.26%/patient-years). Valve dysfunction is defined as stenosis or regurgitation by echocardiogram or cardiac catheterization. There were 21 instances of porcine bioprosthetic dysfunction (6.6% patient-years). Freedom from valve dysfunction at 12 years was 24.4%. There were 17 valves of mitral bioprosthetic dysfunction (6.4% patient-years). The incidences of mitral stenosis (MS), mitral regurgitation (MR), and paravalvular leakage were 4.5, 3.6, and 0.7%/patient-years respectively. Freedom from MR was higher than MS at 8 years. The 14 patients were needed reoperation due to valve dysfunction (3.6%/patient-years). We concluded that the porcine bioprostheses showed a high incidence of valve dysfunction at 7 to 8 years after operation, we presently choose mechanical valve in most cases.  相似文献   