首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
目的分析种植体-基台连接形式对种植体周围骨组织应力分布的影响,从生物力学角度探讨平台转换连接形式防止或减少种植体周围骨吸收的可能机制。方法利用COSMOSM2.85软件包建立种植体支持的下颌第一磨牙三维有限元模型,种植体-基台的连接形式分别采用平齐对接(模型A)和平台转换(模型B)。采用垂直和斜向两种形式加载,载荷均为200N,比较两种模型种植体周围骨组织的应力分布情况以及种植体-骨界面颊舌侧相同位置的von Mises应力大小。结果不同加载条件下两种模型种植体周围骨组织应力集中在种植体颈部颊舌侧骨皮质内,斜向加载时最大von Mises应力值高于垂直加载时。模型A和模型B骨组织内最大von Mises应力值在垂直加载时,分别为11.61MPa和7.15MPa,斜向加载时分别为22.07MPa和11.87MPa。距离种植体-基台连接处越远,von Mises应力值越小,骨皮质到骨松质交界处的应力变化最明显。与模型A相比,模型B种植体-骨界面相同节点的最大von Mises应力值较小。结论与平齐对接形式相比,平台转换设计可改善种植体周围骨组织的应力分布,降低种植体颈部骨组织所受的应力。  相似文献   

2.
This study evaluates the influence of 2 commercially available dental implant systems on stress distribution in the prosthesis, abutment, implant, and supporting alveolar bone under simulated occlusal forces, employing a finite element analysis. The implants and abutments evaluated consisted of a stepped cylinder implant connected to a screw-retained, internal, hexagonal abutment (system 1) and a conical implant connected to a solid, internal, conical abutment (system 2). A porcelain-covered, silver-palladium alloy was used as a crown. In each case, a simulated, 100-N vertical load was applied to the buccal cusp. A finite element model was created based on the physical properties of each component, and the values of the von Mises stresses generated in the prosthesis, abutment, implant, and supporting alveolar bone were calculated. In the prostheses, the maximum von Mises stresses were concentrated at the points of load application in both systems, and they were greater in system 1 (148 N/mm2) than in system 2 (55 N/mm2). Stress was greater on the abutment of system 2 than of system 1 on both the buccal (342 N/mm2 x 294 N/mm2) and lingual (294 N/mm2 x 148 N/ mm2) faces. Stress in the cortical, alveolar bone crest was greater in system 1 than in system 2 (buccal: 99.5 N/mm2 x 55 N/mm2, lingual: 55 N/mm2 x 24.5 N/mm2, respectively). Within the limits of this investigation, the stepped cylinder implant connected to a screw-retained, internal hexagonal abutment produces greater stresses on the alveolar bone and prosthesis and lower stresses on the abutment complex. In contrast, the conical implant connected to a solid, internal, conical abutment furnishes lower stresses on the alveolar bone and prosthesis and greater stresses on the abutment.  相似文献   

3.
The effect of the diameter of hydroxyapatite (HAP) implants on stress distribution in alveolar bone was analyzed by two-dimensional finite element methods (FEM), with use of a 100-N vertical and lateral load. Since HAP is considered a bioactive material, the alveolar bone was assumed to be bonded directly to the HAP implant in the FEM model. The analysis showed that the stresses in cortical bone were generally higher than those in cancellous bone, and that the stress concentration occurred mainly in cortical bone around the neck of the implant with both vertical and lateral load. The stresses in cortical bone with lateral load were especially high-twice those in vertical load. Stresses in cortical bone decrease in inverse proportion to the increase in implant diameter with both vertical and lateral load. The results suggested that an implant with a large diameter is favorable from the standpoint of stress distribution.  相似文献   

4.
STATEMENT OF PROBLEM: Primary implant stability and bone density are variables that are considered essential to achieve predictable osseointegration and long-term clinical survival of implants. Information about the influence of bone quality on stress distribution in an implant-supported crown is limited. PURPOSE: The purpose of this study was to investigate the effect of 4 different bone qualities on stress distribution in an implant-supported mandibular crown, using 3-dimensional (3-D) finite element (FE) analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar tooth was developed, and an implant to receive a crown was developed. A solid 4.1 x 10-mm screw-type dental implant system (ITI; solid implant) and a metal-ceramic crown using Co-Cr (Wiron 99) and feldspathic porcelain were modeled. The model was developed with FE software (Pro/Engineer 2000i program), and 4 types of bone quality (D1, D2, D3, and D4) were prepared. A load of 300 N was applied in a vertical direction to the buccal cusp and distal fossa of the crowns. Optimal bone quality for an implant-supported crown was evaluated. RESULTS: The results demonstrated that von Mises stresses in D3 and D4 bone quality were 163 MPa and 180 MPa, respectively, and reached the highest values at the neck of the implant. The von Mises stress values in D1 and D2 bone quality were 150 MPa and 152 MPa, respectively, at the neck of the implant. A more homogenous stress distribution was seen in the entire bone. Conclusion For the bone qualities investigated, stress concentrations in compact bone followed the same distributions as in the D3 bone model, but because the trabecular bone was weaker and less resistant to deformation than the other bone qualities modeled, the stress magnitudes were greatest for D3 and D4 bone.  相似文献   

5.
目的:对单个种植体周围牙槽骨发生碟形和楔形垂直吸收并处于稳定期时的骨内应力变化状况,进行比较研究。方法:应用MSC-NASTRAN软件建立种植体周围不同形状、不同深度骨缺损的垂直骨吸收稳定期三维有限元模型,在垂直及斜向载荷下进行计算分析。结果:单个种植体周围牙槽骨发生少量垂直吸收后并处于稳定期时,随着骨缺损深度的增加,垂直载荷下骨内最大Von-Mises应力值有很小幅度的波动;斜向载荷下骨内最大Von-Mises应力值会增大,但幅度不大。同等骨缺损深度的碟形和楔形吸收的骨内应力情况相差较小。结论:在骨皮质保持完整及种植体不松动的情况下,种植体周围骨组织发生少量的垂直吸收时,骨内应力情况随缺损深度增加变化不大;而且相同条件下两种形状垂直骨吸收的骨内应力情况较相近。  相似文献   

6.
目的:研究天然牙与种植体联合支持式套筒冠固定桥牙周组织的应力分布情况。方法:选择1例左侧下颌第一磨牙缺失病例,分别设计以左侧下颌第二前磨牙与种植体(位于下颌第二磨牙)联合支持固定桥模型(模型Ⅰ)和套筒冠固定桥模型(模型Ⅱ)。在分散垂直和分散斜向2种载荷情况下,采用三维有限元法分析基牙及种植体周围骨组织的应力分布情况。结果:分散垂直载荷下,模型Ⅰ中的天然牙和种植体周围骨组织最大等效应力值分别为2.58MPa和43.92MPa;模型Ⅱ中,相应的最大等效应力值分别为2.17MPa和20.23MPa。分散斜向载荷下,模型Ⅰ中的天然牙和种植体周围骨组织最大等效应力值分别为2.23MPa和46.37MPa;模型Ⅱ中.相应的最大等效应力值分别为1.91MPa和21.19MPa。结论:套筒冠固位体能缓冲种植体周围骨组织的部分应力,但对垂直应力和侧向应力的缓冲能力差别不大。进行天然牙与种植体联合支持固定桥修复时,可在种植体端设计套筒冠固位体.以缓冲种植体周围骨组织的应力水平,防止或减轻种植体支持组织的损伤。  相似文献   

7.
The aim of this study was to evaluate the stress distribution in the bone around dental and zygomatic implants for 4 different implant-supported obturator prostheses designs in a unilaterally maxillary defect using a 3-dimensional finite element stress analysis. A 3-dimensional finite element model of the human unilateral maxillary defect was constructed. Four different implant-supported obturator prostheses were modeled; model 1 with 2 zygomatic implants and 1 dental implant, model 2 with 2 zygomatic implants and 2 dental implants, model 3 with 2 zygomatic implants and 3 dental implants, and model 4 with 1 zygomatic implant and 3 dental implants. Bar attachments were used as superstructure. A 150-N vertical load was applied in 3 different ways, and von Mises stresses in the cortical bone around implants were evaluated. When the models (model 1-3) were compared in terms of number of implants, all of the models showed similar highest stress values under the first loading condition, and these values were less than under model 4 conditions. The highest stress values of models 1-4 under the first loading condition were 8.56, 8.59, 8.32, and 11.55 Mpa, respectively. The same trend was also observed under the other loading conditions. It may be concluded that the use of a zygomatic implant on the nondefective side decreased the highest stress values, and increasing the number of dental implants between the most distal and most mesial implants on the nondefective side did not decrease the highest stress values.  相似文献   

8.
The biomechanical behavior of implant thread plays an important role on stresses at implant-bone interface. Information about the effect of different thread profiles upon the bone stresses is limited. The purpose of this study was to evaluate the effects of different implant thread designs on stress distribution characteristics at supporting structures. In this study, three-dimensional (3D) finite element (FE) stress-analysis method was used. Four types of 3D mathematical models simulating four different thread-form configurations for a solid screw implant was prepared with supporting bone structure. V-thread (1), buttress (2), reverse buttress (3), and square thread designs were simulated. A 100-N static axial occlusal load was applied to occlusal surface of abutment to calculate the stress distributions. Solidworks/Cosmosworks structural analysis programs were used for FE modeling/analysis. The analysis of the von Mises stress values revealed that maximum stress concentrations were located at loading areas of implant abutments and cervical cortical bone regions for all models. Stress concentration at cortical bone (18.3 MPa) was higher than spongious bone (13.3 MPa), and concentration of first thread (18 MPa) was higher than other threads (13.3 MPa). It was seen that, while the von Mises stress distribution patterns at different implant thread models were similar, the concentration of compressive stresses were different. The present study showed that the use of different thread form designs did not affect the von Mises concentration at supporting bone structure. However, the compressive stress concentrations differ by various thread profiles.  相似文献   

9.
PURPOSE: The biomechanical behavior of an osseointegrated dental implant plays an important role in its functional longevity inside the bone. Studies of this aspect of dental implants by the finite element method are ongoing. In the present study, a cuneiform-geometry implant was considered with a 3-dimensional model that had a mesh that was finer than in the models commonly found in the literature. MATERIALS AND METHODS: A mechanical model of an edentulous mandible was generated from computerized tomography, with the implant placed in the left first premolar region. A 100-N axial load was applied at the implant abutment, and the mandibular boundary conditions were modeled considering the real geometry of its muscle supporting system. The cortical and trabecular bone was assumed to be homogeneous, isotropic, and linearly elastic. RESULTS: The stress analysis provided results that were used to plot global and detailed graphics of normal maximum (S1), minimum (S3), and von Mises stress fields. The results obtained were analyzed and compared qualitatively with the literature. DISCUSSION: Quantitative comparisons were not performed because of basic differences between the model adopted here and those used by other authors. The stress distribution pattern for the studied geometry was similar to those found in the current literature, but insignificant apical stress concentration occurred. The stress concentration occurred at the neck of the implant, ie, in the cortical bone, which was similar to results for other implant shapes reported in the literature. CONCLUSION: The studied geometry showed a smooth stress pattern, with stress concentrated in the cervical region. The values, however, were within the range of values found in the cortical layer far from the implant, caused by the muscular action. No significant stress concentration was found in the apical area.  相似文献   

10.
目的 应用三维有限元法分析动态载荷下基台缓冲层对种植体应力分布的影响。方法 根据CT扫描数据建立种植体在人类下颌骨的三维实体几何模型,在种植体上方分别制作基台无缓冲层和基台有缓冲层的修复体,缓冲部分由高聚合度聚氯乙稀制作。分别对2种修复体施加垂直向载荷200 N、水平向载荷100 N(45°),加载集中于种植体顶部中心。通过三维有限元法分析种植体、中央螺栓、基台的体部和颈部以及下颌骨各部位受到的应力。结果 基台有缓冲层时种植体、中央螺栓、基台的体部和颈部以及下颌骨各部位上受到的应力均明显小于基台无缓冲层时。结论 基台有缓冲层可显著降低种植体、中央螺栓、基台以及下颌骨各部位受到的应力。  相似文献   

11.
An osseointegrated stepped screw dental implant was evaluated using 2-dimensional finite element analysis (FEA). The implant was modeled in a cross section of the posterior human mandible digitized from a computed tomography (CT) generated patient data set. A 15-mm regular platform (RP) Branemark implant with equivalent length and neck diameter was used as a control. The study was performed under a number of clinically relevant parameters: loading at the top of the transmucosal abutment in vertical, horizontal, and 45 degrees oblique 3 orientations. Elastic moduli of the mandible varied from a normal cortical bone level (13.4 GPa) to a trabecular bone level (1.37 GPa). The study indicated that an oblique load and elastic moduli of the cortical bone are important parameters to the implant design optimization. Compared with the cylindrical screw implant, the maximum von Mises stress of the stepped screw implant model was 17.9% lower in the trabecular bone-implant area. The study also showed that the stepped screw implant is suitable for the cortical bone modulus from 10 to 13.4 GPa, which is not necessarily as strict as the Branemark implant, for which a minimum 13.4 GPa cortical bone modulus is recommended.  相似文献   

12.
OBJECTIVES: Although bone loss around implants is reported as a complication when it progresses uncontrolled, resorption does not always lead to implant loss, but may be the result of biomechanical adaptation to stress. To verify this hypothesis, a three-dimensional finite element analysis was performed and the influence of marginal bone resorption amount and shape on stress in the bone and implant was investigated. MATERIAL AND METHODS: A total of nine bone models with an implant were created: a non-resorption (Base) model and eight variations, in which three different resorption depths were combined with pure vertical or conical (vertical-horizontal) resorption. Axial and buccolingual forces were applied independently to the occlusal node at the center of the superstructure. RESULTS: Regardless of load direction, bone stresses were higher in the pure vertical resorption (A) models than in the Base model, and increased with resorption depth. However, cortical bone stress was much lower in the conical resorption models than in both the Base and A models of the same resorption depth. An opposite tendency was observed in the cancellous bone under buccolingual load. Under buccolingual load, highest stress in the implant increased linearly with the resorption depth for all the models and its location approached the void existing below the abutment screw. CONCLUSIONS: The results of this analysis suggest that a certain amount of conical resorption may be the result of biomechanical adaptation of bone to stress. However, as bone resorption progresses, the increasing stresses in the cancellous bone and implant under lateral load may result in implant failure.  相似文献   

13.
Statement of problemA consensus regarding the effects of platform switching on peri-implant marginal bone levels is lacking. Finite element studies have reported contradictory results.PurposeThe purpose of this finite element analysis study was to evaluate stress distribution in platform-switched (PS) and platform-matched (PM) implants and their surrounding bone.Material and methodsAn implant (4.5×11 mm) was modeled and screwed into a human mandibular bone block using a computer-aided design (CAD) software program. Two separate models were generated: (1) PM, 4.5-mm implant with 4.5-mm-wide abutment and (2) PS, 4.5-mm implant with 3.5-mm-wide abutment. Implant components were modeled with linear isotropic properties and bones with anisotropic properties. Vertical (200 to 800 N) and oblique (50 to 150 N) forces were applied to each model to simulate occlusal loads. Linear elastic analysis was performed using ANSYS Workbench 16. von Mises equivalent stresses in the implant assemblies and peri-implant bone were calculated and compared with independent samples t test (α=.05).Resultsvon Mises equivalent stress values under simulated axial and nonaxial occlusal loads were lower for PM than for PS implant assemblies. However, the differences were not statistically significant. Stress within the peri-implant bone was significantly higher for the PM group than for the PS group (P<.001).ConclusionsPlatform switching decreased stress within peri-implant bone and may help limit marginal bone resorption.  相似文献   

14.
Purpose: This finite element analysis investigation evaluated the effect of different implant cross‐sectional designs on bone stress levels under different loading patterns. Materials and Methods: Finite element analysis program was used to construct four different three‐dimensional models describing 4 × 10‐mm implants in blocks of cortical and trabecular bone. A 5‐mm‐long abutment was modeled above each implant. The implant in model 1 was unthreaded, while in model 2 the implant was circularly threaded. The third implant in model 3 had the cross‐sectional shape as a 16‐sided star‐shaped design. The implant in model 4 was constructed unthreaded, with a diameter of 4.5 mm. Vertical and horizontal loads of 100 N each were applied on the top middle node of each implant assembly. All nodes at the bottom surface of the bone models were restrained. Results: By comparing models 1, 2, and 3, the lowest bone stress values under vertical and horizontal forces were observed around the unthreaded implant in model 1 (8.92 and 94.52 MPa, respectively). The highest stress value under vertical loading was shown around the threaded implant in model 2 (10.07 MPa), whereas the highest stress value under horizontal loading was observed around the star‐shaped implant in model 3 (108.40 MPa). Model 4, with a wider unthreaded design, had stress values under vertical and horizontal loading of 7.32 and 71.35 MPa, respectively. Conclusions: It was concluded that the unthreaded implant design produced the least bone stress. An increase in implant diameter could produce marked reduction in stress value in the bone around the neck of the implant.  相似文献   

15.
PURPOSE: A 3-dimensional finite element analysis was performed to evaluate the influence of implant type and length, as well as that of bone quality, on the stress/strain in bone and implant. MATERIALS AND METHODS: Two types (screw and cylinder) and 4 lengths (9.2, 10.8, 12.4, and 14.0 mm) of titanium implants were buried in 4 types of bone modeled by varying the elastic modulus for cancellous bone. Axial and buccolingual forces were applied to the occlusal node at the center of the abutment. RESULTS: Regardless of load direction, maximum equivalent stress/strain in bone increased with a decrease in cancellous bone density. Under axial load, especially in the low-density bone models, maximum equivalent strain in cancellous bone was lower with the screw-type implant than with the cylinder-type implant. It was also lower with the longer implants than with the shorter implants. Under buccolingual load, equivalent stress/strain was influenced mainly by bone density. DISCUSSION: This study confirms the importance of bone quality and its presurgical diagnosis for implant long-term prognosis. Implant length and type can also influence bone strain, especially in low-density bone. CONCLUSIONS: The results of this study suggest that cancellous bone of higher rather than lower density might ensure a better biomechanical environment for implants. Moreover, longer screw-type implants could be a better choice in a jaw with cancellous bone of low density.  相似文献   

16.
PURPOSEZirconia has exceptional biocompatibility and good mechanical properties in clinical situations. However, finite element analysis (FEA) studies on the biomechanical stability of two-piece zirconia implant systems are limited. Therefore, the aim of this study was to compare the biomechanical properties of the two-piece zirconia and titanium implants using FEA.MATERIALS AND METHODSTwo groups of finite element (FE) models, the zirconia (Zircon) and titanium (Titan) models, were generated for the exam. Oblique (175 N) and vertical (175 N) loads were applied to the FE model generated for FEA simulation, and the stress levels and distributions were investigated.RESULTSIn oblique loading, von Mises stress values were the highest in the abutment of the Zircon model. The von Mises stress values of the Titan model for the abutment screw and implant fixture were slightly higher than those of the Zircon model. Minimum principal stress in the cortical bone was higher in the Titan model than Zircon model under oblique and vertical loading. Under both vertical and oblique loads, stress concentrations in the implant components and bone occurred in the same area. Because the material itself has high stiffness and elastic modulus, the Zircon model exhibited a higher von Mises stress value in the abutments than the Titan model, but at a level lower than the fracture strength of the material.CONCLUSIONOwing to the good esthetics and stress controllability of the Zircon model, it can be considered for clinical use.  相似文献   

17.
Background: Several studies on one‐stage surgery in the treatment of the edentulous maxilla with implant‐supported fixed prostheses have reported problems with removable provisional prostheses, which can load the implants in an uncontrollable manner during healing, and jeopardize healing. Immediate splinting of the implants with a fixed provisional prosthesis has been proposed to protect the bone‐implant interface. Purpose: This study used the finite element method (FEM) to simulate stresses induced in bone tissue surrounding uncoupled and splinted implants in the maxilla because of bite force loading, and to determine whether the differences in these stress levels are related to differences in observed bone losses associated with the two healing methods. Materials and Methods: Stress levels in the maxilla were studied using the FEM program TRINITAS (Institute of Technology, Linköping University, Linköping, Sweden) in which all phases – preprocessing/modeling, equation solving, and postprocessing/evaluation – were simulated. Results: Stress levels in bone tissue surrounding splinted implants were markedly lower than stress levels surrounding uncoupled implants by a factor of nearly 9. Conclusion: From a mechanical viewpoint, FEM simulation supports the hypothesis that splinting reduces damage evolution in bone tissue, which agrees with clinical observations.  相似文献   

18.
Background: Short implants present superior failure rates for everybody. Purpose: The aim of this theoretic study was to assess to what extent implant length and bicortical anchorage affect the way stress is transferred to implant components, the implant proper, and the surrounding bone. Materials and Methods: Stress analysis was performed using finite element analysis. A three‐dimensional linear elastic model was generated. All implants modeled were of the same diameter (3.75 mm) but varied in length, at 6, 7, 8, 9, 10, 11, and 12 mm (Branemark System®, Nobel Biocare AB, Gothenburg, Sweden). Each implant was modeled with a titanium abutment screw and abutment, a gold cylinder and prosthetic screw, and a ceramic crown. The implants were seated in a supporting bone structure consisting of cortical and cancellous bone. An occlusal load of 100 N was applied at a 30° angle to the buccolingual plane. Results: With the selected model and bone properties, the coronal cortical anchorage was dominating, and the bone stress concentrated to that area. Conclusions: The maximum bone stress was virtually constant, independent of implant length and bicortical anchorage. The maximum implant stress, however, increased somewhat with implant length and bicortical anchorage.  相似文献   

19.
The effects of implant shape and size on the stress distribution around high-strength silicon nitride implants under vertical and oblique forces were determined using a three-dimensional finite element analysis. Finite element models were designed using as a basis the serial sections of the mandible. Using Auto-CAD software, the model simulated the placement of implants in the molar region of the left mandible. Results of the analyses demonstrated that mainly the implant root shape and the directions of bite forces influence the stress distributions in the supporting bone around each implant. Implant size is a lesser factor. The serrated implants presented a larger surface area to the bone than either the cylindrical or tapered implants, which resulted in lower compressive stress around the serrated implants. With increasing implant diameter and length, compressive stress decreased. The mean compressive stress distribution on the serrated implants was more flat (platykurtic) than on either the cylindrical or tapered implants. Results of studies on two load directions (vertical and oblique) showed that, in either case, the compressive stress in the cortical bone around the neck of the implant was higher than in the cancellous bone along the length of the implant. The most extreme principal compressive stress was found with oblique force. This study provides the first information on the relationship between shape of the silicon nitride implant and stress on the supporting bone.  相似文献   

20.
Abstract

Objective. This study evaluated the influence of framework material and vertical misfit on stress created in an implant-supported partial prosthesis under load application. Materials and methods. The posterior part of a severely reabsorbed jaw with a fixed partial prosthesis above two osseointegrated titanium implants at the place of the second premolar and second molar was modeled using SolidWorks 2010 software. Finite element models were obtained by importing the solid model into an ANSYS Workbench 11 simulation. The models were divided into 15 groups according to their prosthetic framework material (type IV gold alloy, silver-palladium alloy, commercially pure titanium, cobalt-chromium alloy or zirconia) and vertical misfit level (10 µm, 50 µm and 100 µm). After settlement of the prosthesis with the closure of the misfit, simultaneous loads of 110 N vertical and 15 N horizontal were applied on the occlusal and lingual faces of each tooth, respectively. The data was evaluated using Maximum Principal Stress (framework, porcelain veneer and bone tissue) and a von Mises Stress (retention screw) provided by the software. Results. As a result, stiffer frameworks presented higher stress concentrations; however, these frameworks led to lower stresses in the porcelain veneer, the retention screw (faced to 10 µm and 50 µm of the misfit) and the peri-implant bone tissues. Conclusion. The increase in the vertical misfit resulted in stress values increasing in all of the prosthetic structures and peri-implant bone tissues. The framework material and vertical misfit level presented a relevant influence on the stresses for all of the structures evaluated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号