首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
The purpose of the present study was to compare scintimammography using technetium-99m hexakis 2-methoxyisobutylisonitrile (MIBI) with that using 99mTc-hydroxymethylene diphosphonate (HMDP) in the detection of breast cancer and its axillary lesions. The study population comprised 50 consecutive females with breast cancer who were scheduled for surgery. All patients underwent scintimammography with 99mTc-MIBI and 99mTc-HMDP. The images were acquired 5 min (early) and 2 h (delayed) after injection of each radiopharmaceutical. Regions of interest were placed over the breast tumour (T), the axillary lesion (A) and the normal ipsilateral breast tissue (N). The two count ratios were calculated, i.e. the tumour to normal breast tissue ratio (T/N) and the axillary lymph node to normal breast tissue ratio (A/N). For the breast tumours, using 99mTc-MIBI the positive rate was 86% (43/50) for the early and 72% (36/50) for the delayed images. The corresponding values using 99mTc-HMDP were 72% (36/50) and 40% (20/50), respectively. Histopathological examination revealed metastatic lymph node involvement in 22 patients. For the axillary lesions, using 99mTc-MIBI the positive rate was 72.7% (16/22) for the early and 54.5% (12/22) for the delayed images. Using 99mTc-HMDP, the positive rate was only 18.2% (4/22) for the early and 4.5% (1/22) for the delayed images. Using 99mTc-MIBI, the mean T/N (+/- SD) ratios on early and delayed images were 2.69 +/- 1.64 and 2.03 +/- 1.16, respectively, and the mean A/N (+/- SD) ratios on early and delayed images were 2.20 +/- 1.23 and 1.80 +/- 1.20, respectively. The corresponding values using 99mTc-HMDP were 1.77 +/- 0.91, 1.42 +/- 0.72, 1.27 +/- 0.63 and 1.08 +/- 0.25, respectively. The T/N and A/N ratios on the early and delayed 99mTc-MIBI images were both significantly higher than those obtained using 99mTc-HMDP. 99mTc-MIBI scintimammography is more sensitive than 99mTc-HMDP scintimammography for the detection of breast cancer and its axillary lymph node metastases.  相似文献   

2.
PURPOSE: To compare results of planar and SPECT breast imaging with 99mTc-MIBI in detecting primary breast cancer. MATERIAL AND METHODS: Twenty-six consecutive patients with 34 suspected breast lesions underwent both planar and SPECT scintimammography. Ten minutes after injection of 700 MBq 99mTc-MIBI, 2 prone lateral projections were obtained, followed by a supine anterior projection. Forty minutes after injection, a SPECT study was done. All lesions were operated upon and verified with histopathology. RESULTS: A sensitivity of 85% and specificity of 88% of planar scintimammography in diagnosis of primary breast lesions were achieved. The corresponding values for SPECT were 61% and 64%. CONCLUSION: The diagnostic accuracy of planar scintimammography was not improved by using SPECT imaging.  相似文献   

3.
目的:比较99mTcMIBI与99mTcOctreotide生长抑素受体显像对乳腺癌诊断的临床价值。材料和方法:对36例怀疑为乳腺癌的患者术前行99mTcMIBI显像,48小时后行99mTcOctreotide生长抑素受体显像,以术后病理检查结果作为金标准。结果:36例中,25例为乳腺癌,其中11例发生腋窝淋巴结转移;11例患者为乳腺良性病变。两种显像方法对乳腺癌诊断的灵敏度、特异性、准确性分别为92.0%、63.6%、83.3%和92.0%、27.3%、72.2%。结论:99mTcMIBI显像与99mTcOctreotide生长抑素受体显像对乳腺癌均有较好的诊断价值,但99mTcOctreotide生长抑素受体显像诊断特异性较低。由于本研究的病例数有限,有待于进一步的工作深入探讨。  相似文献   

4.
99Tcm-MIBI显像对乳腺癌腋窝转移淋巴结的诊断   总被引:3,自引:1,他引:2  
目的 评价^99Tc^m-甲氧基异丁基异腈(MIBI)显像要诊断乳腺癌腋窝转移淋巴结中的价值,方法 18例病理检查证实的乳腺癌病人,术前均行^99Tcm-MIBI显像,14例乳腺未触及肿块者作为对照组,静脉注射^99Tc^m-MIBI110MBq后5,30和60min进行早期及延迟显像,分别于左侧位,右侧位和前后位进行观察,患者均在显像扣1周内进行手术治疗,腋窝淋巴结清扫后行病理检查。结果 18例  相似文献   

5.
AIM: We evaluated the usefulness of (99m)Tc-tetrofosmin axillary pinhole (P)-SPECT in breast cancer (BC) non palpable axillary lymph node metastasis detection compared with conventional planar and SPECT scintimammography. METHODS: We studied prospectively 188 consecutive patients with suspected primary BC, negative at axillary clinical examination. Ten minutes after 740 MBq (99m)Tc-tetrofosmin injection, planar and SPECT scintimammography were acquired, followed by axillary P-SPECT imaging. RESULTS: At histology, 12 patients had benign mammary lesions and 176 had BC. Axillary lymph node dissection (ALND) was performed in all BC patients, bilaterally in 3 cases: 74/179 axillae had metastases. P-SPECT showed a significantly higher overall sensitivity than SPECT and planar (93.2% vs 85.1% and 36.5%, respectively; p<0.05 and p<0.0005, respectively) and was false negative in 5 patients with 1 metastatic node each, micrometastatic in 4/5 cases; SPECT and planar were also false negative in these 5 cases and in 6 and in 42 further cases, respectively. P-SPECT added important prognostic information by distinguishing single from multiple and pound 3 from >3 nodes; only P-SPECT defined the exact number of nodes in 15/25 patients with 2-4 nodes. P-SPECT showed the highest accuracy and NPV: 92.7% and 95%, respectively (SPECT 90.5% and 90%, respectively; planar 73.2% and 68.9%, respectively). CONCLUSION: (99m)Tc-tetrofosmin axillary P-SPECT appears highly accurate in BC non palpable axillary lymph node metastasis detection and significantly more sensitive than both planar and SPECT, its few false negative results predominantly concerning micrometastases; moreover, only P-SPECT gave additional important prognostic information. Given its very high NPV, P-SPECT could also be used to better select patients who might avoid ALND.  相似文献   

6.
目的 比较99Tcm tetrofosmin和99Tcm 甲氧基异丁基异腈 (MIBI)显像诊断乳腺癌和腋淋巴结转移的临床价值。方法 对 5 2例乳腺肿瘤患者进行99Tcm tetrofosmin和99Tcm MIBI显像。患者均在 2周内行外科手术治疗 ,并做病理检查。结果  2 6例患者病理检查证实为乳腺癌 ,其中 30例为良性病变。99Tcm tetrofosmin显像发现乳腺癌 2 1例 ,其中 11例合并腋淋巴结转移 ;99Tcm MIBI显像发现乳腺癌 19例 ,其中 12例合并腋淋巴结转移。99Tcm tetrofosmin和99Tcm MIBI显像对乳腺癌诊断的灵敏度、特异性和准确性分别为 80 8%、76 7%、78 6 %和 73 1%、73 3%、73 2 % ;诊断腋淋巴结转移的灵敏度、特异性和准确性分别为 6 8 8%、80 0 %、76 0 %和 75 0 %、80 0 %、76 9%。结论 99Tcm tetrofosmin显像对乳腺癌的检出优于99Tcm MIBI显像  相似文献   

7.
PURPOSE: The aim of our prospective study was to determine the diagnostic accuracy of planar breast imaging with 99mTc-MIBI in detecting malignant disease. MATERIAL AND METHODS: Ninety-six consecutive patients with 121 clinically- and/or mammographically-detected breast lesions underwent preoperative planar scintimammography. Ten minutes after injection of 700 MBq 99mTc-MIBI, two lateral prone and one anterior supine projections with an acquisition time of 8 minutes each were obtained. Interpretation of scintimammographic results was made blindly and any focal accumulation of MIBI in the breasts was the criterion for an abnormal scintigram. All lesions were operated on and histologically verified. RESULTS: Histologically, 86 malignant and 35 benign lesions were found in 121 breast lesions. A sensitivity of 83.7% and a specificity of 74.2% for malignancy was achieved at planar scintimammography. CONCLUSION: Scintimammography with 99mTc-MIBI is an imaging modality of modest usefulness in the investigation of breast lesions. The method has a low sensitivity in lesions smaller than 10 mm in diameter, which decreases the clinical use of the method.  相似文献   

8.
Single photon emission computed tomography (SPECT)/CT is emerging as a useful diagnostic tool in several oncological fields. In this prospective study, we assessed the usefulness of Tc-99m-tetrofosmin SPECT/CT in the detection of both residual breast tumors and axillary lymph node metastases following neoadjuvant therapy. Thirty-seven consecutive breast cancer patients scheduled to surgery following neoadjuvant therapy preoperatively underwent a Tc-99m-tetrofosmin SPECT/CT study, using a dual head gamma camera integrated with a x-ray tube for low-dose CT, including both breasts and axillary regions in the field of view. Within 1 week of SPECT/CT, all 37 patients had breast surgery with associated axillary lymph node dissection in 33/37 cases. At surgery, 31/37 patients had breast residues (microscopic in 4/31 cases and macroscopic in 27/31 cases). Axillary lymph node metastases were ascertained in 19/33 cases (N1mi: 2 cases, N1a: 8 cases, N2a: 6 cases, N2b: 3 cases). SPECT/CT sensitivity, specificity, and accuracy in detecting residual tumors were 87%, 100%, and 89.2%, respectively; the corresponding values in detecting axillary lymph node metastases were 36.8%, 92.8%, and 60.6%. SPECT/CT missed breast cancer residues in 4/31 patients, including 2 cases with microscopic residual disease. Moreover, lymph node metastases were missed in 12/19 patients (10/12 with pN1mi or pN1a metastases), all with lymph nodes with post-therapy fibrotic changes and small deposits of metastases. Tc-99m-tetrofosmin SPECT/CT proved a useful diagnostic tool in the detection and in the localization of residual breast tumors following neoadjuvant therapy. The procedure lacked in sensitivity in identifying axillary lymph node metastases, especially in patients with a limited lymph node involvement. According to our data, SPECT/CT may guide the surgeon to the most appropriate breast surgical treatment and to eventually select the most suitable axillary lymph node sampling (axillary lymph node dissection or sentinel node biopsy).  相似文献   

9.
OBJECTIVE: Pulmonary Kaposi's sarcoma (KS) occurs in more than 10% of patients with acquired immunodeficiency syndrome (AIDS) and has a high mortality rate. Prompt detection, diagnosis, and treatment reduce patient morbidity and mortality. The objective of this study was to determine the efficacy of 99mTc-hexakis-2-methoxy isobutyl isonitrile (99mTc-MIBI) imaging in detecting pulmonary AIDS-related KS. METHODS: 99mTc-MIBI imaging was performed on 72 human immunodeficiency virus-seropositive patients with bronchoscopic diagnosis of pulmonary KS (36 patients), pneumonia (22), normal tracheo-bronchial tree (11), lymphoma (2), and bronchogenic carcinoma (1). Lung uptake and lymph node detection in KS were compared on planar and single photon emission computed tomography (SPECT) scans. RESULTS: The lung/myocardium ratios on the 1-h planar images were significantly higher in KS and normal lungs than opportunistic infection. Using the lung/myocardium ratio of 1 as cutoff, the sensitivity, specificity, and accuracy of the 1-h planar images for detecting pulmonary KS were 75, 57.58, and 66.67%, respectively. Abnormal lymph node uptake, pleural/pericardial effusions, and ascites were detected more readily on SPECT. CONCLUSION: Planar 99mTc-MIBI imaging has moderate sensitivity, specificity, and accuracy for detecting pulmonary KS. SPECT is more effective in detecting abnormal lymph nodes, pleural/pericardial effusions, and ascites. 99mTc-MIBI SPECT followed by planar imaging at 40-60 min can be useful in assessing pulmonary KS.  相似文献   

10.
Axillary lymph node status is important in the staging of breast carcinoma. To evaluate the accuracy of technetium-99m sestamibi breast scintigraphy in detecting metastatic axillary lymph nodes as compared with other accepted imaging modalities, we performed99mTc-sestamibi breast scintigraphy, conventional mammography and ultrasound in 36 patients with primary untreated breast carcinoma. With histopathology as the gold standard,99mTc-sestamibi breast scintigraphy was found to yield true-positive results in 7 of 11 cases (64%) of axillary lymph node metastases and true-negative results in 18 of 20 cases (90%); it has an accuracy of 81%, a positive predictive value of 77.8% and a negative predictive value of 81.8%.  相似文献   

11.
The aim of this prospective study was to determine the diagnostic value of prone lateral 99Tcm-MIBI scintimammography in the detection of primary breast cancer and axillary lymph node involvement in patients with breast lesions. We evaluated 83 palpable and 22 non-palpable lesions in 77 consecutive patients with a clinically palpable mass and/or suspicious mammographic finding. Early and late scintimammograms were performed after the intravenous injection of 740 MBq 99Tcm-MIBI. The overall sensitivity of both scintimammography and mammography in the detection of primary breast cancer was 94%. The overall specificity was 84% and 56% for scintimammography and mammography respectively. In the patients with palpable masses, the sensitivity of scintimammography was 97% and the specificity was 84%; in those with non-palpable masses, the sensitivity was 35% and the specificity 100%. For the detection of axillary lymph node involvement, the sensitivity and specificity of scintimammography were 68% and 93% respectively. However, conventional mammography showed 37% sensitivity and 86% specificity. In conclusion, scintimammography is an accurate and clinically valuable tool for evaluating palpable and non-palpable breast abnormalities. In addition to its high sensitivity, it improves the specificity of mammography both in the evaluation of breast masses and in the detection of axillary involvement.  相似文献   

12.
The aim of this study was to evaluate the usefulness of (99m)Tc-tetrofosmin single-photon emission tomography (SPET) in the detection of both primary breast cancer and axillary lymph node metastasis. We studied 192 consecutive patients in whom primary breast cancer was suspected on the basis of mammography and/or physical examination. After intravenous injection of 740 MBq (99m)Tc-tetrofosmin, both planar and SPET scintimammography was performed in all patients using a rectangular dual-head gamma camera equipped with low-energy, high-resolution, parallel-hole collimators. In 175 patients with breast cancer at histology, the per-lesion overall sensitivity of SPET and planar imaging for the detection of breast cancer was 95.8% and 75.9% (P<0.0005), respectively. The sensitivity of SPET and planar imaging was, respectively, 96.5% and 79.5% in palpable (P<0.0005) and 90% and 45% in non-palpable lesions (P<0.01). With regard to lesion size, the sensitivity of SPET and planar imaging was, respectively, 90.5% and 45.2% in lesions < or =10 mm ( P<0.0005), 95.3% and 81.4% in lesions of 11-20 mm (P<0.005), 100% and 84.6% in lesions of 21-30 mm (P<0.05) and 100% and 95.8% in lesions >30 mm (P>0.05). In the remaining 17 patients with benign mammary lesions at histology, per-lesion overall specificity of SPET and planar imaging was 76.2% and 85.7% (P>0.05), respectively. Neither SPET nor planar imaging showed false-positive results in non-palpable lesions or in those < or =10 mm. In 173 breast cancer patients submitted to axillary lymph node dissection (ALND), per-axilla overall sensitivity of SPET and planar imaging in the detection of axillary lymph node metastasis was 93% and 52.3% ( P<0.0005), respectively. The sensitivity of SPET and planar imaging was, respectively, 100% and 82.6% in palpable nodes (P>0.05), 90.5% and 41.3% in non-palpable nodes (P<0.0005), 92.8% and 35.7% in the presence of < or =3 nodes ( P<0.0005) and 93.2% and 68.2% in the presence of >3 nodes (P<0.005). The specificity of SPET and planar imaging was 91% and 100% (P<0.05), respectively. (99m)Tc-tetrofosmin SPET appears to be a reliable method for the detection of both primary BC and axillary lymph node metastasis, and its diagnostic accuracy exceeds that of (99m)Tc-tetrofosmin planar scintimammography. The use of SPET is particularly important in the identification of small non-palpable primary carcinomas and metastatic axillae with < or =3 non-palpable lymph nodes. More extensive use of SPET appears warranted in the management of breast cancer patients.  相似文献   

13.
目的:探讨乳癌哨兵淋巴结活检预测腋窝淋巴结转移状态的可靠性.方法:本组为2000年11月至2004年2月我院收治的140例乳癌患者.术中应用国产亚甲蓝注射液4~6 ml肿瘤上、外、下半圆形皮下连续注射,134例行乳癌改良根治术或患侧乳腺区段切除加腋窝淋巴结清扫术.术后解剖蓝染淋巴管,沿着色淋巴管找到蓝染的哨兵淋巴结.哨兵淋巴结及腋窝淋巴结常规行石蜡病理切片检查.5例行乳腺区段切除加哨兵淋巴结活检,1例行全乳切除加哨兵淋巴结活检(冰冻、石蜡病理检查SLN转移阴性),未行全腋窝淋巴结清扫.结果:140例患者中136例检出哨兵淋巴结,检出率97.14%,灵敏度 88.71%,准确率94.31%,阴性预测值89.71%,假阴性率11.29%,仅哨兵淋巴结阳性7例.结论:应用亚甲蓝注射液淋巴结着色方法行乳癌哨兵淋巴结活检可以准确地预测腋窝淋巴结转移状态.  相似文献   

14.
The purpose of the present study was to compare scintimammography using technetium-99m hexakis 2-methoxyisobutylisonitrile (MIBI) with that using 99mTc-hydroxymethylene diphosphonate (HMDP) in the detection of breast cancer and its axillary lesions. The study population comprised 50 consecutive females with breast cancer who were scheduled for surgery. All patients underwent scintimammography with 99mTc-MIBI and 99mTc-HMDP. The images were acquired 5 min (early) and 2 h (delayed) after injection of each radiopharmaceutical. Regions of interest were placed over the breast tumour (T), the axillary lesion (A) and the normal ipsilateral breast tissue (N). The two count ratios were calculated, i.e. the tumour to normal breast tissue ratio (T/N) and the axillary lymph node to normal breast tissue ratio (A/N). For the breast tumours, using 99mTc-MIBI the positive rate was 86% (43/50) for the early and 72% (36/50) for the delayed images. The corresponding values using 99mTc-HMDP were 72% (36/50) and 40% (20/50), respectively. Histopathological examination revealed metastatic lymph node involvement in 22 patients. For the axillary lesions, using 99mTc-MIBI the positive rate was 72.7% (16/22) for the early and 54.5% (12/22) for the delayed images. Using 99mTc-HMDP, the positive rate was only 18.2% (4/22) for the early and 4.5% (1/22) for the delayed images. Using 99mTc-MIBI, the mean T/N (-SD) ratios on early and delayed images were 2.69ǃ.64 and 2.03ǃ.16, respectively, and the mean A/N (-SD) ratios on early and delayed images were 2.20ǃ.23 and 1.80ǃ.20, respectively. The corresponding values using 99mTc-HMDP were 1.77ǂ.91, 1.42ǂ.72, 1.27ǂ.63 and 1.08ǂ.25, respectively. The T/N and A/N ratios on the early and delayed 99mTc-MIBI images were both significantly higher than those obtained using 99mTc-HMDP. 99mTc-MIBI scintimammography is more sensitive than 99mTc-HMDP scintimammography for the detection of breast cancer and its axillary lymph node metastases.  相似文献   

15.
PURPOSE: To evaluate the predictive value of sentinel lymph node biopsy versus axillary node dissection on lymph node status in patients with T1-T2 breast cancer. MATERIAL AND METHODS: Twenty-nine patients with T1 and 12 with T2 breast carcinoma and clinically N0 axillary lymph nodes, underwent lymphoscintigraphy following the administration of 99mTc-human albumin nanocolloids. The tracer was injected subdermally, over the tumor mass, in the 34 patients with palpable lesions and peritumorally (n=3) or intratumorally (n=4), under stereotactic or ultrasound guidance, in the 7 patients with non-palpable lesions. Anterior and lateral planar images were acquired 15 min after the injection of the tracer and repeated every 30 min up to 3 hr until identification of sentinel lymph node. At the end of the scintigraphic study, sentinel node skin projection was marked using a dermographic pen. Eighteen hours after lymphoscintigraphy, sentinel lymph node was identified and removed during surgery by hand-held gamma probe, then, the remaining axillary lymph nodes were dissected. All surgical specimens underwent histologic examination. Sentinel lymph nodes free of metastasis at histology, underwent additional examination with immunohistochemistry using monoclonal antibodies against cytokeratin and EMA to search for micrometastases. RESULTS: Sentinel lymph node was identified in the 34 patients injected subdermally and in the 3 patients injected peritumorally, while it remained undetected in the 4 patients injected intratumorally except for one case in which it was isolated by radioguided surgery but not scintigraphically. Sentinel nodes resulted free of metastases both at histology and immunohistochemistry in 32 cases and metastatic in 6. In the 32 patients with non-metastatic sentinel lymph nodes the other axillary nodes were also free of metastases. Among the 6 metastatic sentinel lymph nodes, in 3 cases they were the only metastatic nodes of the axilla while in the other 3 cases metastases were spread to other axillary nodes. CONCLUSIONS: In agreement with previous studies, our results showed that sentinel lymph node radioguided biopsy is a simple and reliable method for predicting axillary lymph nodes status and for avoiding axillary dissection in early breast cancer patients with sentinel node free of metastases.  相似文献   

16.
The aim of the study was to evaluate the possible role of scintimammography (SMM) with technetium-99m tetrofosmin in breast cancer. Thirty-three patients with breast disease and ten normal controls were included in the study. Planar scintigraphic images in supine anterior, prone lateral and lateral views, with the patient lying in lateral recumbency, were acquired. A qualitative analysis evaluating both breasts and lymph nodes was performed. All breast lesions were verified after surgery and/or by fine-needle aspiration. In 8 of the 33 patients, mammography was inconclusive because of mastectomy or dense breasts. For mammography, a sensitivity of 95.6%, a specificity of 66.7% and an accuracy of 89.6% were obtained. At SMM, 26 out of 28 malignant lesions (average size 2.8 cm, range 0.4–12 cm), including two recurrences, were detected with a 92.8% sensitivity, a 100% specificity and a 95.1% accuracy. The smallest detectable carcinoma measured 0.6 cm. Two false-negative results on SMM were found in a 0.4-cm intraductal carcinoma and in the only mucinous papillary carcinoma in our series. With regard to lymph node analysis, 11 out of 12 axillary metastases (sensitivity=91.6%) were detected. A false-positive result, yielding a specificity of 92.3% was also obtained. A metastatic involvement of the internal mammary chain was observed. No uptake was seen in 11 benign mammary lesions or at the level of the breast and axilla when neoplastic involvement was absent. In conclusion, SMM with99mTc-tetrofosmin is an effective technique for the evaluation of primary breast carcinomas, recurrences and lymph node metastases.  相似文献   

17.
The aim of this study was to evaluate the usefulness of 99mTc-tetrofosmin single-photon emission tomography (SPET) in the detection of both primary breast cancer and axillary lymph node metastasis. We studied 192 consecutive patients in whom primary breast cancer was suspected on the basis of mammography and/or physical examination. After intravenous injection of 740 MBq 99mTc-tetrofosmin, both planar and SPET scintimammography was performed in all patients using a rectangular dual-head gamma camera equipped with low-energy, high-resolution, parallel-hole collimators. In 175 patients with breast cancer at histology, the per-lesion overall sensitivity of SPET and planar imaging for the detection of breast cancer was 95.8% and 75.9% (P<0.0005), respectively. The sensitivity of SPET and planar imaging was, respectively, 96.5% and 79.5% in palpable (P<0.0005) and 90% and 45% in non-palpable lesions (P<0.01). With regard to lesion size, the sensitivity of SPET and planar imaging was, respectively, 90.5% and 45.2% in lesions ⢪ mm (P<0.0005), 95.3% and 81.4% in lesions of 11-20 mm (P<0.005), 100% and 84.6% in lesions of 21-30 mm (P<0.05) and 100% and 95.8% in lesions >30 mm (P>0.05). In the remaining 17 patients with benign mammary lesions at histology, per-lesion overall specificity of SPET and planar imaging was 76.2% and 85.7% (P>0.05), respectively. Neither SPET nor planar imaging showed false-positive results in non-palpable lesions or in those ⢪ mm. In 173 breast cancer patients submitted to axillary lymph node dissection (ALND), per-axilla overall sensitivity of SPET and planar imaging in the detection of axillary lymph node metastasis was 93% and 52.3% (P<0.0005), respectively. The sensitivity of SPET and planar imaging was, respectively, 100% and 82.6% in palpable nodes (P>0.05), 90.5% and 41.3% in non-palpable nodes (P<0.0005), 92.8% and 35.7% in the presence of Г nodes (P<0.0005) and 93.2% and 68.2% in the presence of >3 nodes (P<0.005). The specificity of SPET and planar imaging was 91% and 100% (P<0.05), respectively. 99mTc-tetrofosmin SPET appears to be a reliable method for the detection of both primary BC and axillary lymph node metastasis, and its diagnostic accuracy exceeds that of 99mTc-tetrofosmin planar scintimammography. The use of SPET is particularly important in the identification of small non-palpable primary carcinomas and metastatic axillae with Г non-palpable lymph nodes. More extensive use of SPET appears warranted in the management of breast cancer patients.  相似文献   

18.
The aim of this study was to see how effective ultrasound-guided needle biopsy was at detecting lymph node involvement in patients with early breast cancer. Patients with newly diagnosed invasive breast cancer underwent axillary ultrasound (US) where lymph node size and morphology were noted. A core biopsy (CB) was undertaken of any node greater than 5 mm in longitudinal section. Patients with benign CBs proceeded to sentinel lymph node (SLN) biopsy, whereas those with malignancy underwent axillary lymph node dissection (ALND). US and CB findings were correlated with final surgical histology in all cases. One hundred and thirty-nine patients were examined, of whom 52.5% had lymph node metastases on final histology. One hundred and twenty-one patients (87%) underwent axillary node CB. The overall sensitivity of CB for detecting lymph node metastases was 53.4% (60.3% for macrometastases; 26.7% for micrometastases). The US morphological characteristics most strongly associated with malignancy were absence of a hilum and a cortical thickness greater than 4 mm. However, one third of patients with normal lymph node morphology had nodal metastases, and only 12% of these were diagnosed on CB. CB of axillary lymph nodes can diagnose a substantial number of patients with lymph node metastases, allowing these patients to proceed directly to ALND, avoiding unnecessary SLN biopsy.  相似文献   

19.
BACKGROUND AND PURPOSE: The increasing use of systemic adjuvant therapy even in lymph node-negative breast cancer patients and breast cancer screening programs detecting smaller tumors with less probability of metastatic lymph nodes questions the need for routine axillary lymph node dissection. Since morbidity of breast cancer surgery is predominantly related to axillary lymph node dissection, predictive models for lymph node involvement may provide a way to avoid lymph node surgery and its side effects in subgroups of patients. PATIENTS AND METHODS: Using a multivariate logistic regression model, tumorbiological parameters such as expression of estrogen and progesterone receptors, Ki-67, p53, cathepsin D, HER2, S-phase fraction, and ploidy were analyzed regarding their ability to predict axillary lymph node involvement in 655 breast cancer patients. RESULTS: The model correctly predicted axillary lymph node metastases in 58% of the patients by including expression of progesterone receptor, HER2, and Ki-67. In a subgroup of 200 patients predicted to be at extremely high or extremely low risk for axillary lymph node metastases, the accuracy of the prediction was 70%. CONCLUSION: With a model just based on tumorbiological parameters obtained in the primary tumor it is possible to predict axillary lymph node status. By including additional parameters it appears to be feasible to further improve the model in order to avoid axillary lymph node surgery in low-risk women.  相似文献   

20.
We include those patients who present with an isolated metastasis of axillary adenopathy in the occult primary breast cancer group. Presumably, the primary tumor is a primitive breast carcinoma, unsuspected until this moment and not clinically demonstrable by mammography or ultrasonography. When no method succeeds in confirming the primary breast lesion, the patients are usually treated assuming the existing of breast cancer. Several diagnostic methods have been used to find the primary breast lesion. Magnetic Resonance imaging (MRI), Positron Emission (PET) and Doppler sonography have been used in this way and several papers present the results reached with them. Our group incorporates detection and radioguided surgery with 99mTechnetium (99mTc) methoxyisobutil isonitrile into the study of these patients. We perform a planar scintimammography and SPECT (Single Photon Emission Computed Tomography) with 99mTc-MIBI. If the radioisotopic method shows a functional image compatible with a carcinoma, a gamma detecting probe is then used to locate the lesion and guide its surgical removal. In this paper, we present the application of the technique in 5 cases and describe the technique and its possibilities. Its advantages are explained in comparison with other methods. The dosimetric values found in the performance of the technique are reported. We consider that detection and radioguided surgery with 99mTc-MIBI in the diagnosis and treatment of occult breast cancer adds an effective tool and means progress in the approach to this disease.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号