首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
胫骨干骨折后骨不连、骨不愈合是骨科常见并发症之一。自2004年1月-2005年6月采用闭合穿针交锁髓内针或普通髓内针内固定治疗胫骨干骨折23例,3例失去联系,随访20例,骨折处均正常愈合,现报告如下。1临床资料本组病例共23例,男19例,女4例;年龄17~63岁,平均33岁。23例均为外伤所致。左侧15例,右侧8例。均为新鲜闭合性骨折。按AO长管状骨骨折综合分类:42-A1·2类5例,42-A2·3类2例,42-A3·3类3例,42-B1·2类6例,42-B3·3类3例,42-B2·2类3例,42-C1·1类1例。伤后至手术时间3h~5d。2手术方法选用持续硬膜外麻醉,患者仰卧位,手术台尾板向下倾…  相似文献   

2.
目的 比较胫骨平台后内侧劈裂骨折3种不同内固定方式的生物力学性能.方法 将24具人工合成右侧胫骨根据胫骨平台后内侧劈裂骨折形态学特征建立胫骨平台后内侧劈裂骨折模型,随机分成3组,每组8具,分别采用前内侧有限接触动力加压钢板固定(A组)、外侧锁定钢板固定(B组)、后侧T型支撑钢板固定(C组),测量不同内固定组在轴向载荷500、1000及1500 N下的垂直位移和最大失效载荷. 结果 A、B、C组500 N载荷下骨折块的相对位移分别为(0.376±0.022)、(0.268±0.024)、(0.131±0.019)mm,1000 N载倚下相对位移分别为(0.871±0.031)、(0.593±0.039)、(0.437±0.064)mm,1500 N时相对位移分别为(1.460±0.083)、(1.293±0.075)、(0.842±0.117)mm,3组间两两比较差异均有统计学意义(P<0.05).A、B、C组失效载荷分别为(2360±217)、(3083±190)、(3545±250)N,3组间两两比较差异均有统计学意义(P<0.05). 结论 后侧T型钢板固定组抗载荷力学性能稳定性最强,对固定胫骨平台后内侧劈裂骨折有临床意义.  相似文献   

3.
胫骨骨折与髓内固定   总被引:13,自引:0,他引:13  
陈哨军 《中华骨科杂志》2003,23(12):739-742
胫骨骨折髓内固定按生物力学原理可分为“静力性髓内固定”和“动力性髓内固定”,按材料韧性可分为“弹性针髓内固定”和“刚性针髓内固定”,按技术操作可分为“扩髓髓内固定”和“非扩髓髓内固定”。髓内固定的优势很多,如有较好的骨折稳定性,有利于早期负重并促进骨愈合,能较早、较好地恢复肢体功能,闭合穿针技术符合现代骨折生物学  相似文献   

4.
目的 探讨不同方法 固定胫骨不稳定pilon骨折的生物力学性能. 方法 用7具新鲜国人踝关节标本制备Ruedi-Allgower Ⅲ型pilon骨折,根据不同固定方法 分5组,A组:内侧支撑钢板固定,B组:胫骨远端前外侧解剖型钢板加内侧空心钉固定,C组:外侧外固定支架加内侧空心钉固定,D组:外侧外固定支架加内侧支撑钢板固定,E组:内侧外固定支架加胫骨远端前外侧解剖型钢板固定.比较各组的强度、刚度、失效载荷等生物力学性能. 结果 A、B、C、D、E组胫骨远端的抗压应力值分别为(1.31±0.10)、(1.61±0.14)、(1.17±0.13)、(0.90±0.08)、(0.98±0.08)MPa,轴向刚度分别为(1224.49±115.40)、(1016.95±102.32)、(1395.34±140.12)、(1935.48±180.42)、(1764.71±174.76)N/mm,水平剪切刚度分别为(3076.92±304.20)、(2553.19±250.73)、(3529.41±344.42)、(4800.00±490.61)、(4444.45±451.52)N/mm,失效载荷分别为(2448±208)、(2034±184)、(2791±265)、(3871±382)、(3529±342)N,等效刚度值分别为(703±56)、(583±62)、(805±74)、(1100±108)、(1035±110)N·m/Deg. 结论 对于胫骨不稳定性pilon骨折,采用胫骨内侧支撑钢板或胫骨远端前外侧解剖型钢板附加外固定支架固定,不但具有优越的生物力学性能,等效刚度高,而且固定坚强、可靠,操作方便,踝关节稳定性好,为Ruedi-Allgower Ⅲ型pilon骨折切开复位手术固定选择提供了理论参考.  相似文献   

5.
克氏针加小夹板治疗胫骨骨折的生物力学研究   总被引:1,自引:0,他引:1  
目的 探讨克氏针加小夹板治疗胫骨骨折的优势和可行性及其生物力学。方法 用克氏针加小夹板治疗胫骨骨折29例(共31侧)。结果 随访5至24个月,所有病例均在2.5至4.5个月内达骨性愈合。结论 克氏针加小夹板治疗胫骨骨折,手术创伤小,能最大限度保留骨折端血运,固定牢靠,有良好的力学优势。  相似文献   

6.
梅花针固定治疗胫骨双段骨折   总被引:1,自引:0,他引:1  
  相似文献   

7.
目的 比较4种不同内固定方式治疗胫骨平台后外侧剪应力骨折的生物力学性能.方法 将40具人工合成右侧胫骨模型根据胫骨平台后外侧剪应力骨折的形态学特征建立胫骨平台后外侧剪应力骨折模型,随机分成4组(n=10):A组采用前外侧2枚拉力螺钉固定,B组采用前内侧有限接触动力加压钢板(LC-DCP)固定,C组采用外侧解剖锁定钢板固定,D组采用后外侧支撑钢板固定.测量4组在轴向载荷500、1000及1500 N下的垂直位移和最大失效载荷.结果 A、B、C、D组在500 N载荷下骨折块的相对位移分别为(0.459±0.045)、(0.365±0.035)、(0.264±0.025)、(0.128±0.018)mm,在1000 N载荷下骨折块相对位移分别为(1.058±0.091)、(0.882±0.053)、(0.551±0.053)、(0.440±0.068)mm,在1500 N载荷下骨折块的相对位移分别为(1.559±0.097)、(1.466±0.079)、(1.291±0.077)、(0.832±0.130)mm,同一载荷下D组与其他3组比较差异均有统计学意义(P<0.05).A、B、C、D组失效载荷分别为(1870±156)、(2520±186)、(2816±190)、(3465±210)N,D组与其他3组比较差异均有统计学意义(P<0.05).结论 后外侧支撑钢板固定组抗载荷力学性能最佳,对固定胫骨平台后外侧剪应力骨折有明显的生物力学优势.  相似文献   

8.
解剖钢板固定治疗胫骨远端骨折   总被引:1,自引:0,他引:1  
2002~2006年,我科应用胫骨远端解剖钢板治疗胫骨远端骨折患者31例,取得满意疗效。  相似文献   

9.
目的总结交锁髓内钉在胫骨骨折不愈合治疗中临床应用初步结果和手术技巧,并分析其适应证的选择和疗效.方法自2001年10月至2003年3月共采用交锁髓内钉合并植骨术治疗32 例胫骨骨折不愈合病例,其中男性22 例,女性10 例,年龄27~48 岁,平均年龄33 岁.术前,2次手术的5 例,1次手术的27 例.踝前板固定的8 例,解剖板固定的6 例,普通钢板固定的3 例,加压钢板固定的8 例,外固定架固定的7 例.术中有一助手把持描准器,抵消重力影响使之与胫骨冠状面平行,确保锁钉一次成功.结果对32 例患者骨折愈合情况,静力固定改动力固定的时限选择、交锁髓内钉的特点以及对骨折愈合的影响进行分析.术后12~16周连续骨痂通过骨折线改动力固定,术后7~11个月骨折完全愈合.所有病例双下肢等长,负重无疼痛,无跛行,关节功能正常.结论交锁髓内钉合并植骨治疗胫骨骨折不愈合,适应证宽,对血运破坏小,及时改静力固定为动力固定,使应力轴线上的骨痂及植入物不断加强和改造,骨折愈合牢固,关节功能恢复好.  相似文献   

10.
胫骨多段骨折又称为节段性骨折,临床上并非少见,治疗上有较多争议,国内少有专题报道。我科自1990年以来,采用梅花针内固定治疗胫骨多段骨折17例,收到满意效果。现介绍如下。 1 临床资料 1.1 一般资料 本组17例,男性12例,女性5例;年龄21~62岁,平均36岁。高能量损伤15例,其中车祸伤9例,重物  相似文献   

11.
目的:观察自制跟骨解剖钢板及易断螺栓系统的生物力学性能,同时研究其固定跟骨骨折的有效性。方法:将16具新鲜足标本随机分为试验组与对照组,分别进行轴向加压损伤试验,制成跟骨骨折模型,并记录试验组标本的最大栽荷及最大足弓位移。试验组标本采用自制钢板螺栓系统进行内固定,对照组行传统AO钢板螺钉固定。完成固定后进行轴向加压试验,测量并记录两组标本的最大载荷、足弓位移和跟骨增宽。结果:试验组标本发生跟骨骨折时的最大栽荷、足弓最大位移分别为(5711.19±86.55)N和(18.57±2.79)mm,经自制钢板螺栓系统固定后的最大载荷及负荷600N时的足弓位移、足弓最大位移、跟骨增宽分别为(7866.74±181.58)N、(1.54±0.87)m/l/、(19.35±3.64)mm和(0.54±0.37)mm。对照组跟骨骨折模型经AO钢板螺钉固定后,测得最大载荷及负荷600N时的足弓位移、跟骨增宽分别为(6702.94±241.06)N、(3.31±1.07)mm和(1.73±0.69)mm。试验组标本行内固定前、后进行比较,最大载荷的差异具有统计学意义(P〈0.01),而最大足弓位移间差异无统计学意义(P〉0.05);固定后两组标本之间比较,各参数间差异均具有统计学意义(P〈0.01)。结论:跟骨骨折经自制内固定系统治疗后完全能达到正常足的生物力学性能,并能维持足弓强大的载荷,跟骨解剖钢板及易断螺栓系统的固定强度和效果均优于AO钢板螺钉内固定系统。  相似文献   

12.
目的 探讨外固定器固定骨折时轴向加压骨折端髓内、髓外的在体生物力学变化。方法 选用健康大耳白兔 18只 ,随机均分A、B组 ,A组为髓外测量组 ,B组为髓内测量组 ,根据轴向加压的大小各分为A1和A2 ,B1和B2组。结果 A组加压定标曲线早期变化大 ,达到稳态后与髓腔内趋势相同 ,但髓腔外应变值明显大于髓腔内。B组加压达到稳态时间短 ,应变绝对值较A组小 ;加压后达到稳态前 ,A1与A2相比 ,衰减速度低 ,B1与B2相比结果相同 ,A与B组相比 ,A组下降后有上升趋势 ,B组无上升趋势。达到稳态后 ,A1、A2均有下降趋势 ,A2下降速度快 ,B1维持一定水平。B2出现波动。结论 轴向加压时骨折端髓外应变值均显大于髓内 ,髓内较髓外易达到稳定状态 ,外固定器治疗骨折时初期加压量以 0 .5倍体重为宜。  相似文献   

13.
Objective: To investigate the different ways of measuring the main axial strain during treatment with an external fixator and to find the suitable compression loaded by the external fixator at an early stage. Methods: Eighteen healthy big-ear rabbits were randomly divided into two groups according to different measuring methods: Group A and Group B. In Group A, a strain gauge was affixed to the external tibial cortex with 502 glue, and in Group B, a bone cement-coated strain gauge was installed on the internal tibial cortex. Groups A and B were divided into two subgroups A1, A2 and B1, B2, respectively, according to the pressure of half of and the same as the body weight. A Z-shaped left mid-shaft tibial osteotomy was performed and fixed by an external fixator. Results: The sealer curves of Group A changed dramatically during the early stage. The trendlines of the internal and external cortex went consistently after reaching the stable stage while the latter strain value was higher than the former. The time for Group B reaching the stable stage was short, but its absolute strain value was less than that of Group A. Before they were pressed to the stable stage, the declined speed of Subgroup A1 was more slowly than that of Subgroup A2 while the results of Subgroups Bl and B2 were same. Group A had an ascending trend after it declined while Group B didn' t have. After they reached the stable stage, both Subgroups Al and A2 had a declining trend while Subgroup A2 was more quickly than Subgroup A1, Subgroup Bl was kept at a definite level while Subgroup B2 fluctuated. Conclusions: The axial strain under external fixator can be measured by bone cement coated-strain gauge in vivo. The data may suggest that half of the body weight load was suitable for external fixator.  相似文献   

14.
This study tested the hypothesis that interfragmentary axial movement of transverse diaphyseal osteotomies would result in improved fracture healing compared to interfragmentary shear movement. Ten skeletally mature merino sheep underwent a middiaphyseal osteotomy of the right tibia, stabilized by external fixation with an interfragmentary gap of 3 mm. A custom made external fixator allowed either pure axial (n=5) or pure shear movement (n=5) of 1.5 mm amplitude during locomotion by the animals. The movement of the osteotomy gap was monitored weekly in two sheep by an extensometer temporarily attached to the fixator. After 8 weeks the sheep were killed, and healing of the osteotomies was evaluated by radiography, biomechanical testing, and undecalcified histology. Shear movement considerably delayed the healing of diaphyseal osteotomies. Bridging of the osteotomy fragments occurred in all osteotomies in the axial group (100%), while in the shear group only three osteotomies (60%) were partially bridged. Peripheral callus formation in the shear group was reduced by 36% compared to the axial group (p<0.05). In the axial group bone formation was considerably larger at the peripheral callus and in between the osteotomy gaps but not in the intramedullary area. The larger peripheral callus and excess in bone tissue at the level of the gap resulted in a more than three times larger mechanical rigidity for the axial than for the shear group (p<0.05). In summary, fixation that allows excessive shear movement significantly delayed the healing of diaphyseal osteotomies compared to healing under axial movement of the same magnitude.  相似文献   

15.
从生物力学角度探讨斜形与横形骨折对骨折愈合的影响   总被引:5,自引:0,他引:5  
目的 探讨斜形与横形骨折对骨折愈合速度影响的关系。方法 根据骨骼压电效应原理、临床观察、骨折临床愈合标准,并经电子计算机有限元计算,比较斜形与横形不同骨折形状骨折愈合的快慢。结果 横形骨折复位满意后固定牢固稳定,在骨折的早、中、后期均可承受压应力产生压电效应,斜形骨折则不能,而压电效应可促进骨痂生长。在悬臂梁状态(相当于上肢平举)骨折端所受应力与斜形或横形骨折的形状并无明显关系,而与骨折部位有很大关系。结论 在同一个体、相同部位、骨折复位好的情况下横形骨折比斜形骨折愈合较快。  相似文献   

16.
 目的 比较张力带接骨板、2枚骶髂螺钉和可调式微创骨盆后环接骨板治疗骨盆后环纵 行骨折的固定效果。方法选择 8具成年男性非骨质疏松性骨盆标本, 保留骶髂复合体, 剔除其余软组 织, 制作右侧骶骨纵行骨折模型;±次应用张力带接骨板、2枚骶髂螺钉、可调式微创骨盆后环接骨板行 规范化固定。将标本以坐位固定于生物力学试验机, 首先以 20 N/s的速度对标本施加 0~620N的垂直 负荷, 记录标本移位程度;然后以 0.1°/s的角速度加载扭转负荷, 记录扭转角度及对应的扭矩。采用方差 分析比较不同内固定物的固定效果。结果 在垂直负荷作用下, 可调式微创骨盆后环接骨板固定骨盆 的移位与 2枚骶髂螺钉固定骨盆的移位无明显差别, 两者移位均小于张力带接骨板固定骨盆的移位。 在扭转负荷下, 可调式微创骨盆后环接骨板固定骨盆的扭矩与 2枚骶髂螺钉固定骨盆的扭矩无明显差 别, 两者均大于张力带接骨板固定骨盆的扭矩。结论 在垂直负荷和扭转负荷作用下, 可调式微创骨盆 后环接骨板固定骨盆的稳定性与 2枚骶髂螺钉固定效果相同, 两者均优于张力带接骨板。  相似文献   

17.
Fracture site axial rigidity was monitored non-destructively at weekly intervals during healing of tibial osteotomies in adult rabbits. Two groups of 20 rabbits each were treated with external fixators of two different rigidities. Four animals from each group were killed at 3, 5, 6, 7, and 8 weeks to determine the bending moments at failure of the healing fractures. Normal fracture healing was accompanied by characteristic phases in the development of fracture site axial rigidity. From 0 to 3 weeks there was a period of low and approximately constant rigidity, followed by a linear increase during 3 to 5 weeks to an approximately three to four times greater rigidity. The maximum average normalized axial rigidities were reached at 6 weeks and were 57% (high rigidity group) and 77% (low rigidity group) of the untreated contralateral controls. The maximum average normalized failure moments occurred at 8 weeks and were 48% (high rigidity) and 44% (low rigidity) of controls. The differences due to fixator rigidity were not statistically significant except for a large increase in failure moments at 3 weeks for the low rigidity group. Axial rigidities were correlated (r2 = 0.74 and 0.53, respectively) with failure moments, but only during the first 6 weeks. The monitoring technique provides a nondestructive means for following the biomechanical progress of fracture healing in an animal model. The occurrence of the characteristic increase in fracture site axial rigidity at 3 to 5 weeks can also be used to distinguish between normal and abnormal healing.  相似文献   

18.
内外固定联合在不稳定性胫腓骨骨折治疗中的应用   总被引:1,自引:0,他引:1  
杨延民  周驱 《中国骨伤》2004,17(1):36-37
自1998年以来,我院采用小切口切开复位有限内固定结合单侧多功能外固定支架治疗不稳定性胫腓骨骨折17例,随访1年以上者14例,0.5~1年者3例,效果满意,尤其是对胫腓骨中下1/3粉碎性骨折疗效显著,现报告如下。  相似文献   

19.
肖四旺  吴官保  孙达武 《中国骨伤》2001,14(11):649-651
目的:介绍螺管支架固定牵引器的使用方法和治疗腓骨干骨折的临床特性。方法:用自蝗螺管支架固定牵引器治疗胫腓骨干骨折80例,并与跟骨牵引组在X线片骨痂,踝关节僵硬,临床痊愈等方面对照研究,结果:螺管支架组在6周后的骨痂X线评分及防止踝关节僵硬,促进骨折愈合等方面明显优于跟骨牵引组,结论:螺管支架固定牵引器适合于胫腓骨干各型骨折,操作简便,疗效可靠。  相似文献   

20.
高金华  胡炜  郭晓山 《中国骨伤》2015,28(8):753-756
目的:探讨经皮螺钉内固定联合外固定架治疗不稳定骨盆骨折的临床效果。方法:自2006年4月至2009年5月,采用闭合复位内固定联合外固定架治疗29例旋转不稳定型骨盆骨折患者,男19例,女10例;年龄19~53岁,平均31岁。按照Tile分型:C1型17例,C2型12例。术后采用Tornetta标准和Majeed功能评分进行疗效评价。结果:29例患者均获随访,时间10~24个月,平均16个月。术后无神经损伤及盆腔脏器损伤等并发症发生,伤口愈合好,仅1例出现钉道口感染,换药后治愈。骨折均获骨性愈合,愈合时间为14~18周,平均16.2周。未见螺钉松动、脱出、断裂。按照Tornetta评价,优 14例,良10例,可 4例,差 1 例。末次随访Majeed评分为87.2±11.3,优16例,良9例,可4例。结论:对于不稳定C1、C2型骨盆骨折,采用闭合复位内固定联合外固定架可以取得满意的治疗效果。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号