首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Armato SG  Altman MB  Wilkie J  Sone S  Li F  Doi K  Roy AS 《Medical physics》2003,30(6):1188-1197
We have evaluated the performance of an automated classifier applied to the task of differentiating malignant and benign lung nodules in low-dose helical computed tomography (CT) scans acquired as part of a lung cancer screening program. The nodules classified in this manner were initially identified by our automated lung nodule detection method, so that the output of automated lung nodule detection was used as input to automated lung nodule classification. This study begins to narrow the distinction between the "detection task" and the "classification task." Automated lung nodule detection is based on two- and three-dimensional analyses of the CT image data. Gray-level-thresholding techniques are used to identify initial lung nodule candidates, for which morphological and gray-level features are computed. A rule-based approach is applied to reduce the number of nodule candidates that correspond to non-nodules, and the features of remaining candidates are merged through linear discriminant analysis to obtain final detection results. Automated lung nodule classification merges the features of the lung nodule candidates identified by the detection algorithm that correspond to actual nodules through another linear discriminant classifier to distinguish between malignant and benign nodules. The automated classification method was applied to the computerized detection results obtained from a database of 393 low-dose thoracic CT scans containing 470 confirmed lung nodules (69 malignant and 401 benign nodules). Receiver operating characteristic (ROC) analysis was used to evaluate the ability of the classifier to differentiate between nodule candidates that correspond to malignant nodules and nodule candidates that correspond to benign lesions. The area under the ROC curve for this classification task attained a value of 0.79 during a leave-one-out evaluation.  相似文献   

2.
Wang J  Engelmann R  Li Q 《Medical physics》2007,34(12):4678-4689
Accurate segmentation of pulmonary nodules in computed tomography (CT) is an important and difficult task for computer-aided diagnosis of lung cancer. Therefore, the authors developed a novel automated method for accurate segmentation of nodules in three-dimensional (3D) CT. First, a volume of interest (VOI) was determined at the location of a nodule. To simplify nodule segmentation, the 3D VOI was transformed into a two-dimensional (2D) image by use of a key "spiral-scanning" technique, in which a number of radial lines originating from the center of the VOI spirally scanned the VOI from the "north pole" to the "south pole." The voxels scanned by the radial lines provided a transformed 2D image. Because the surface of a nodule in the 3D image became a curve in the transformed 2D image, the spiral-scanning technique considerably simplified the segmentation method and enabled reliable segmentation results to be obtained. A dynamic programming technique was employed to delineate the "optimal" outline of a nodule in the 2D image, which corresponded to the surface of the nodule in the 3D image. The optimal outline was then transformed back into 3D image space to provide the surface of the nodule. An overlap between nodule regions provided by computer and by the radiologists was employed as a performance metric for evaluating the segmentation method. The database included two Lung Imaging Database Consortium (LIDC) data sets that contained 23 and 86 CT scans, respectively, with 23 and 73 nodules that were 3 mm or larger in diameter. For the two data sets, six and four radiologists manually delineated the outlines of the nodules as reference standards in a performance evaluation for nodule segmentation. The segmentation method was trained on the first and was tested on the second LIDC data sets. The mean overlap values were 66% and 64% for the nodules in the first and second LIDC data sets, respectively, which represented a higher performance level than those of two existing segmentation methods that were also evaluated by use of the LIDC data sets. The segmentation method provided relatively reliable results for pulmonary nodule segmentation and would be useful for lung cancer quantification, detection, and diagnosis.  相似文献   

3.
肺癌一直是严重威胁人类健康的疾病之一,肺结节作为早期肺癌的一个重要征象,在肺癌的早期诊断与治疗中具有重要的意义。传统的CT影像肺结节检测方法不仅步骤繁琐、处理速度慢,而且对于结节的检出率及定位精度都亟待提高。提出一种基于非对称卷积核YOLO V2网络的CT影像肺结节检测方法:首先将连续的CT序列叠加构造为伪彩色数据集,以增强病变和健康组织的差异;然后将含有非对称卷积核的inception V3模块引入到YOLO V2网络中,构造出一种适用于肺结节检测的深度网络,一方面利用YOLO V2网络在目标检测上的优势,另一方面通过inception V3模块在网络的宽度与深度上进行扩增,以提取更加丰富的特征;为进一步提高结节的定位精度,对损失函数的设计与计算方法也进行一定的改进。为验证所提检测模型的性能,从LIDC-IDRI数据集中选取1 010个病例的CT图像用于训练和测试,在大于3 mm的肺结节中,检测敏感度为94.25%,假阳性率为8.50%。实验表明,所提出的肺结节检测方法不仅可以简化肺部CT图像的处理过程,而且在结节检测率及定位精度方面均优于传统方法,可为肺结节检测提供一种新思路。  相似文献   

4.
Aoyama M  Li Q  Katsuragawa S  Li F  Sone S  Doi K 《Medical physics》2003,30(3):387-394
An automated computerized scheme has been developed for determination of the likelihood measure of malignancy of pulmonary nodules on low-dose helical CT (LDCT) images. Our database consisted of 76 primary lung cancers (147 slices) and 413 benign nodules (576 slices). With this automated computerized scheme, the location of a nodule was first indicated by a radiologist. The outline of the nodule was segmented automatically by use of a dynamic programming technique. Various objective features on the nodules were determined by use of outline analysis and image analysis, and the likelihood measure of malignancy was determined by use of linear discriminant analysis (LDA). The effect of many different combinations of features and the performance of LDA in distinguishing benign nodules from malignant ones were evaluated by means of receiver operating characteristic (ROC) analysis. The Az value (area under the ROC curve) obtained by the computerized scheme in distinguishing benign nodules from malignant ones was 0.828 when a single slice was employed for each of the nodules. However, the Az value was improved to 0.846 when multiple slices were used for determination of the likelihood measure of malignancy. The Az values obtained by the computerized scheme on LDCT images were significantly greater than the Az value of 0.70, which was obtained from our previous observer studies by radiologists in distinguishing benign nodules from malignant ones on LDCT images. The automated computerized scheme for determination of the likelihood measure of malignancy would be useful in assisting radiologists to distinguish between benign and malignant pulmonary nodules on LDCT images.  相似文献   

5.
We have investigated the effect of computed tomography (CT) image reconstruction algorithm on the performance of our automated lung nodule detection method. Commercial CT scanners offer a choice of several algorithms for the reconstruction of projection data into transaxial images. Different algorithms produce images with substantially different properties that are apparent not only quantitatively, but also through visual assessment. During some clinical thoracic CT examinations, patient scans are reconstructed with multiple reconstruction algorithms. Thirty-eight such cases were collected to form two databases: one with patient projection data reconstructed with the "standard" reconstruction algorithm and the other with the same patient projection data reconstructed with the "lung" reconstruction algorithm. The automated nodule detection method was applied to both databases. This method is based on gray-level-thresholding techniques to segment the lung regions from each CT section to create a segmented lung volume. Further gray-level-thresholding techniques are applied within the segmented lung volume to identify a set of lung nodule candidates. Rule-based and linear discriminant classifiers are used to differentiate between lung nodule candidates that correspond to actual nodules and those that correspond to non-nodules. The automated method that was applied to both databases was exactly the same, except that the classifiers were calibrated separately for each database. For comparison, the classifier then was trained on one database and tested independently on the other database. When applied to the databases in this manner, the automated method demonstrated overall a similar level of performance, indicating an encouraging degree of robustness.  相似文献   

6.
Automated detection of lung nodules in CT scans: preliminary results   总被引:15,自引:0,他引:15  
We have developed a fully automated computerized method for the detection of lung nodules in helical computed tomography (CT) scans of the thorax. This method is based on two-dimensional and three-dimensional analyses of the image data acquired during diagnostic CT scans. Lung segmentation proceeds on a section-by-section basis to construct a segmented lung volume within which further analysis is performed. Multiple gray-level thresholds are applied to the segmented lung volume to create a series of thresholded lung volumes. An 18-point connectivity scheme is used to identify contiguous three-dimensional structures within each thresholded lung volume, and those structures that satisfy a volume criterion are selected as initial lung nodule candidates. Morphological and gray-level features are computed for each nodule candidate. After a rule-based approach is applied to greatly reduce the number of nodule candidates that corresponds to nonnodules, the features of remaining candidates are merged through linear discriminant analysis. The automated method was applied to a database of 43 diagnostic thoracic CT scans. Receiver operating characteristic (ROC) analysis was used to evaluate the ability of the classifier to differentiate nodule candidates that correspond to actual nodules from false-positive candidates. The area under the ROC curve for this categorization task attained a value of 0.90 during leave-one-out-by-case evaluation. The automated method yielded an overall nodule detection sensitivity of 70% with an average of 1.5 false-positive detections per section when applied to the complete 43-case database. A corresponding nodule detection sensitivity of 89% with an average of 1.3 false-positive detections per section was achieved with a subset of 20 cases that contained only one or two nodules per case.  相似文献   

7.
Surface morphology and shape in general are important predictors for the behavior of solid-type lung nodules detected on CT. More broadly, shape analysis is useful in many areas of computer-aided diagnosis and essentially all scientific and engineering disciplines. Automated methods for shape detection have all previously, to the author’s knowledge, relied on some sort of geometric measure. I introduce Normal Mode Analysis Shape Detection (NMA-SD), an approach that measures shape indirectly via the motion it would undergo if one imagined the shape to be a pseudomolecule. NMA-SD allows users to visualize internal movements in the imaging object and thereby develop an intuition for which motions are important, and which geometric features give rise to them. This can guide the identification of appropriate classification features to distinguish among classes of interest. I employ normal mode analysis (NMA) to animate pseudomolecules representing simulated lung nodules. Doing so, I am able to assign a testing set of nodules into the classes circular, elliptical, and irregular with roughly 97 % accuracy. This represents a proof-of-principle that one can obtain shape information by treating voxels as pseudoatoms in a pseudomolecule, and analyzing the pseudomolecule’s predicted motion.  相似文献   

8.
Lung nodule detection in low-dose and thin-slice computed tomography   总被引:3,自引:0,他引:3  
A computer-aided detection (CAD) system for the identification of small pulmonary nodules in low-dose and thin-slice CT scans has been developed. The automated procedure for selecting the nodule candidates is mainly based on a filter enhancing spherical-shaped objects. A neural approach based on the classification of each single voxel of a nodule candidate has been purposely developed and implemented to reduce the amount of false-positive findings per scan. The CAD system has been trained to be sensitive to small internal and sub-pleural pulmonary nodules collected in a database of low-dose and thin-slice CT scans. The system performance has been evaluated on a data set of 39 CT containing 75 internal and 27 sub-pleural nodules. The FROC curve obtained on this data set shows high values of sensitivity to lung nodules (80-85% range) at an acceptable level of false positive findings per patient (10-13 FP/scan).  相似文献   

9.
肺癌是对人类生命健康危害最大的恶性肿瘤之一。计算机辅助诊断系统对肺部CT图像进行自动分析后,可提示医生可疑肺结节,从而克服医生在诊断中的一些主观因素,为此本文提出了一种基于胸部CT图像的可疑肺结节自动检测算法。首先,根据胸部组织的特殊结构,利用一种新的分割算法提取出肺实质部分;在此基础上提取出灰度与结节相近的感兴趣区域,包括结节、肺血管、支气管;然后,以已标记的结节数据作为样本集,计算结节的面积、灰度均值、灰度方差、圆形度、形状矩、体积、球形度等特征值,利用最近邻法建立分类器判别函数;最后,计算测试集感兴趣区域的上述特征,对其进行判别、分类,并标记出结节。试验结果表明,该算法综合考虑了肺结节特征,具有较高的准确度。  相似文献   

10.
We present a number of approaches based on the radial gradient index (RGI) to achieve false-positive reduction in automated CT lung nodule detection. A database of 38 cases was used that contained a total of 82 lung nodules. For each CT section, a complementary image known as an "RGI map" was constructed to enhance regions of high circularity and thus improve the contrast between nodules and normal anatomy. Thresholds on three RGI parameters were varied to construct RGI filters that sensitively eliminated false-positive structures. In a consistency approach, RGI filtering eliminated 36% of the false-positive structures detected by the automated method without the loss of any true positives. Use of an RGI filter prior to a linear discriminant classifier yielded notable improvements in performance, with the false-positive rate at a sensitivity of 70% being reduced from 0.5 to 0.28 per section. Finally, the performance of the linear discriminant classifier was evaluated with RGI-based features. RGI-based features achieved a substantial improvement in overall performance, with a 94.8% reduction in the false-positive rate at a fixed sensitivity of 70%. These results demonstrate the potential role of RGI analysis in an automated lung nodule detection method.  相似文献   

11.
Texture Feature Analysis for Computer-Aided Diagnosis on Pulmonary Nodules   总被引:1,自引:0,他引:1  
Differentiation of malignant and benign pulmonary nodules is of paramount clinical importance. Texture features of pulmonary nodules in CT images reflect a powerful character of the malignancy in addition to the geometry-related measures. This study first compared three well-known types of two-dimensional (2D) texture features (Haralick, Gabor, and local binary patterns or local binary pattern features) on CADx of lung nodules using the largest public database founded by Lung Image Database Consortium and Image Database Resource Initiative and then investigated extension from 2D to three-dimensional (3D) space. Quantitative comparison measures were made by the well-established support vector machine (SVM) classifier, the area under the receiver operating characteristic curves (AUC) and the p values from hypothesis t tests. While the three feature types showed about 90 % differentiation rate, the Haralick features achieved the highest AUC value of 92.70 % at an adequate image slice thickness, where a thinner or thicker thickness will deteriorate the performance due to excessive image noise or loss of axial details. Gain was observed when calculating 2D features on all image slices as compared to the single largest slice. The 3D extension revealed potential gain when an optimal number of directions can be found. All the observations from this systematic investigation study on the three feature types can lead to the conclusions that the Haralick feature type is a better choice, the use of the full 3D data is beneficial, and an adequate tradeoff between image thickness and noise is desired for an optimal CADx performance. These conclusions provide a guideline for further research on lung nodule differentiation using CT imaging.  相似文献   

12.
We are developing a computer-aided diagnosis (CAD) system to classify malignant and benign lung nodules found on CT scans. A fully automated system was designed to segment the nodule from its surrounding structured background in a local volume of interest (VOI) and to extract image features for classification. Image segmentation was performed with a three-dimensional (3D) active contour (AC) method. A data set of 96 lung nodules (44 malignant, 52 benign) from 58 patients was used in this study. The 3D AC model is based on two-dimensional AC with the addition of three new energy components to take advantage of 3D information: (1) 3D gradient, which guides the active contour to seek the object surface, (2) 3D curvature, which imposes a smoothness constraint in the z direction, and (3) mask energy, which penalizes contours that grow beyond the pleura or thoracic wall. The search for the best energy weights in the 3D AC model was guided by a simplex optimization method. Morphological and gray-level features were extracted from the segmented nodule. The rubber band straightening transform (RBST) was applied to the shell of voxels surrounding the nodule. Texture features based on run-length statistics were extracted from the RBST image. A linear discriminant analysis classifier with stepwise feature selection was designed using a second simplex optimization to select the most effective features. Leave-one-case-out resampling was used to train and test the CAD system. The system achieved a test area under the receiver operating characteristic curve (A(z)) of 0.83 +/- 0.04. Our preliminary results indicate that use of the 3D AC model and the 3D texture features surrounding the nodule is a promising approach to the segmentation and classification of lung nodules with CAD. The segmentation performance of the 3D AC model trained with our data set was evaluated with 23 nodules available in the Lung Image Database Consortium (LIDC). The lung nodule volumes segmented by the 3D AC model for best classification were generally larger than those outlined by the LIDC radiologists using visual judgment of nodule boundaries.  相似文献   

13.
An automated method is being developed in order to identify corresponding nodules in serial thoracic CT scans for interval change analysis. The method uses the rib centerlines as the reference for initial nodule registration. A spatially adaptive rib segmentation method first locates the regions where the ribs join the spine, which define the starting locations for rib tracking. Each rib is tracked and locally segmented by expectation-maximization. The ribs are automatically labeled, and the centerlines are estimated using skeletonization. For a given nodule in the source scan, the closest three ribs are identified. A three-dimensional (3D) rigid affine transformation guided by simplex optimization aligns the centerlines of each of the three rib pairs in the source and target CT volumes. Automatically defined control points along the centerlines of the three ribs in the source scan and the registered ribs in the target scan are used to guide an initial registration using a second 3D rigid affine transformation. A search volume of interest (VOI) is then located in the target scan. Nodule candidate locations within the search VOI are identified as regions with high Hessian responses. The initial registration is refined by searching for the maximum cross-correlation between the nodule template from the source scan and the candidate locations. The method was evaluated on 48 CT scans from 20 patients. Experienced radiologists identified 101 pairs of corresponding nodules. Three metrics were used for performance evaluation. The first metric was the Euclidean distance between the nodule centers identified by the radiologist and the computer registration, the second metric was a volume overlap measure between the nodule VOIs identified by the radiologist and the computer registration, and the third metric was the hit rate, which measures the fraction of nodules whose centroid computed by the computer registration in the target scan falls within the VOI identified by the radiologist. The average Euclidean distance error was 2.7 +/- 3.3 mm. Only two pairs had an error larger than 10 mm. The average volume overlap measure was 0.71 +/- 0.24. Eighty-three of the 101 pairs had ratios larger than 0.5, and only two pairs had no overlap. The final hit rate was 93/101.  相似文献   

14.
The purpose of this study was to evaluate the factors limiting nodule detection in thoracic computed tomography (CT) and to determine whether prior knowledge of nodule size and attenuation, available from a baseline CT study, influences the minimum radiation dose at which nodule surveillance CT scans can be performed while maintaining current levels of nodule detectability. Multiple nodules varying in attenuation (-509 to + 110 HU) and diameter (1.6 to 9.5 mm) were layered in random and ordered sequences within 2 lung cylinders made of Rando lung material and suspended within a custom-built CT phantom. Multiple CT scans were performed at varying kVp (120, 100, and 80), mA (200, 150, 100, 50, 20, and 10), and beam collimation (5, 2.5, and 1.25 mm) on a four-row multidetector scanner (Lightspeed, General Electric, Milwaukee, WI) using 0.8 s gantry rotation. The corresponding range of radiation dose over which images were acquired was 0.3-26.4 mGy. Nine observers independently performed three specific tasks, namely: (1) To detect a 3.2 mm nodule of 23 HU; (2) To detect 3.2 mm nodules of varying attenuation (-509 to -154 HU); and (3) To detect nodules varying in size (1.6-9 mm) and attenuation (-509 to 110 HU). A two-alternative forced-choice test was used in order to determine the limits of nodule detection in terms of the proportion of correct responses (Pcorr, related to the area under the ROC curve) as a summary metric of observer performance. The radiation dose levels for detection of 99% of nodules in each task were as follows: Task 1 (1 mGy); Task 2 (5 mGy); and Task 3 (7 mGy). The corresponding interobserver confidence limits were 1, 5, and 10 mGy for Tasks 1, 2, and 3, respectively. There was a fivefold increase in the radiation dose required for detection of lower-density nodules (Tasks 1 to 2). Absence of prior knowledge of the nodule size and density (Task 3) corresponds to a significant increase in the minimum required radiation dose. Significant image degradation and reduction in observer performance for all tasks occur at a dose of < or = 1 mGy. It is concluded that the size and attenuation of a nodule strongly influence the radiation dose required for confident evaluation with a minimum threshold value of 1-2 mGy (minimum dose CT). A prior knowledge of nodule size and attenuation is available from the baseline CT scan and is an important consideration in minimizing the radiation exposure required for nodule detection with surveillance CT.  相似文献   

15.
肺结节是肺部最常见的病变之一,肺结节的早期检测和诊断对于肺癌的早期诊治十分重要.近年来,随着多层螺旋CT(MSCT)、高分辨CT(HRCT)及低剂量胸部CT(LDCT)的应用,计算机辅助诊断(CAD)系统的必要性和重要性也日益显现.由于CAD系统可以明显提高诊断医生的工作效率,为更多的患者服务,因此成为国内外相关领域专家的研究热点,近几年来也取得了一定的成果.就肺结节的CT计算机辅助检测和诊断的基本方法和应用作一综述. Abstract: Lung nodules are one of the most common pathological changes, thus early detection of lung nodule is very important for the diagnosis medical treatment of lung eancer. In recent years, as the application of multi-slice spiral CT(MSCT), high-resolution CT(HRCT) and low-dose chest CTCLDCT), computer-aided diagnosis (CAD) system will be more essential and more important. Since CAD system can improve the working efficiency of doctors and provide service to more patients, has become the research hotspot and achievement has been made in relevant area internationally recently. This review summarizes the basic methods and applieations of computer-aided detection and diagnosis of lung nodule based on CT image.  相似文献   

16.
The aim of this study is to evaluate the effect of multiscale processing in digital chest radiography on automated detection of lung nodule with a computer-aided diagnosis (CAD) system. The study involved 58 small-nodule patient cases and 58 normal cases. The 58 patient cases included a total of 64 noncalcified lung nodules up to 15 mm in diameter. Each case underwent an examination with a digital radiography system (Digital Diagnost, Philips Medical Systems), and the acquired image was processed by the following three types of multiscale processing (Unique Image Processing Package, Philips Medical Systems) respectively: (1) standard image from the default processing parameter (structure preference, 0.0), (2) high-pass image with structure preference of 0.4, (3) low-pass image with structure preference of ?0.4. The CAD output images were produced with a real-time computer assistance system (IQQA?-Chest, EDDA Technology). Two experienced chest radiologists established the nodule gold standard by consensus reading according to computed tomography results, and analyzed and recorded the detection of lung nodules and false-positive detections of these CAD output images. For the entire cases involved (each case with three types of different processing), a total of 348 observations were evaluated by the receiver operating characteristic (ROC) analysis. The mean area under the ROC curve (A z ) value was 0.700 for the standard images, 0.587 for the high-pass images, and 0.783 for the low-pass images. There were statistically significant A z values among these three types of processed images (p?<?0.01). Multiscale processing in digital chest radiography can affect the automated detection of lung nodule by CAD, which is consistent with effects from visual inspection.  相似文献   

17.
针对肺结节检测的肺实质CT图像分割   总被引:1,自引:0,他引:1  
目的:针对CT图像上肺结节的自动检测,开发并评价对全肺螺旋CT扫描中的肺实质进行自动分割的一种综合方法。方法:首先利用全局阈值对CT图像进行二值化,然后消除由于支气管、细支气管等低密度影和由于结节、血管等高密度影以及由检查床造成的条状伪影等噪声,最后对包含胸膜连接结节的图像利用数学形态学运算和图像凸包运算进行完善形成肺实质掩膜。结果:利用该方法对从LIDC数据库中所有包含结节的505张CT扫描片(来自69个病例)进行肺实质分割,正确率为95.4%。其中,包含胸膜连接结节的139张CT扫描片的正确分割率为94.2%。结论:本文提出的方法较好地完成了肺实质分割任务,为利用CT图像进行计算机辅助肺结节的检测打下了基础。  相似文献   

18.
Pu J  Zheng B  Leader JK  Wang XH  Gur D 《Medical physics》2008,35(8):3453-3461
The authors present a new computerized scheme to automatically detect lung nodules depicted on computed tomography (CT) images. The procedure is performed in the signed distance field of the CT images. To obtain an accurate signed distance field, CT images are first interpolated linearly along the axial direction to form an isotropic data set. Then a lung segmentation strategy is applied to smooth the lung border aiming to include as many juxtapleural nodules as possible while minimizing over segmentations of the lung regions. Potential nodule regions are then detected by locating local maximas of signed distances in each subvolume with values and the sizes larger than the smallest nodule of interest in the three-dimensional space. Finally, all detected candidates are scored by computing the similarity distance of their medial axis-like shapes obtained through a progressive clustering strategy combined with a marching cube algorithm from a sphere based shape. A free-response receiver operating characteristics curve is computed to assess the scheme performance. A performance test on 52 low-dose CT screening examinations that depict 184 verified lung nodules showed that during the initial stage the scheme achieved an asymptotic maximum sensitivity of 95.1% (175/184) with an average of 1200 suspicious voxels per CT examination. The nine missed nodules included two small solid nodules (with a diameter < or =3.1 mm) and seven nonsolid nodules. The final performance level after the similarity scoring stage was an absolute sensitivity level, namely, including the nine missed during the initial stage, of 81.5% (150/184) with 6.5 false-positive identifications per CT examination. This preliminary study demonstrates the feasibility of applying a simple and robust geometric model using the signed distance field to identify suspicious lung nodules. In the authors' data set the sensitivity of this scheme is not affected by nodule size. In addition to potentially being a stand alone approach, the signed distance field based method can be easily implemented as an initial filtering step in other computer-aided detection schemes.  相似文献   

19.
One of the unanswered questions in digital radiography is the connection between physical image quality metrics and clinical detection performance. In this paper, we examine the impact of two physical metrics, resolution and noise, on the detectability of nodules in a pulmonary background for specific digital radiographic detectors. A detection experiment was performed on a simulated image set using anatomical backgrounds from a high-quality lung radiograph and three different simulated nodule sizes (2-3.5 mm). The resolution and noise of the resulting images were modified using existing routines to simulate a selenium-based and a cesium iodide-based flat-panel detector at comparable exposures. A location-known-exactly (LKE) observer performance experiment was performed in which four experienced chest radiologists and three physicists specializing in chest radiology scored the images. The data from the observer experiment were analyzed by receiver operating characteristic (ROC) methodology. The detectability, as measured by the parameter Az, was higher for the selenium detector than the cesium iodide detector for all nodule sizes by an average of 8.5%. For one nodule size (2.75 mm), the difference between detectors was statistically significant (p < 0.01). The findings indicate that for the particular task studied, the superior resolution performance of the selenium-based detector provided better detectability of subtle lung nodules even though the images had greater noise than images obtained with the cesium iodide detector.  相似文献   

20.
Suzuki K  Armato SG  Li F  Sone S  Doi K 《Medical physics》2003,30(7):1602-1617
In this study, we investigated a pattern-recognition technique based on an artificial neural network (ANN), which is called a massive training artificial neural network (MTANN), for reduction of false positives in computerized detection of lung nodules in low-dose computed tomography (CT) images. The MTANN consists of a modified multilayer ANN, which is capable of operating on image data directly. The MTANN is trained by use of a large number of subregions extracted from input images together with the teacher images containing the distribution for the "likelihood of being a nodule." The output image is obtained by scanning an input image with the MTANN. The distinction between a nodule and a non-nodule is made by use of a score which is defined from the output image of the trained MTANN. In order to eliminate various types of non-nodules, we extended the capability of a single MTANN, and developed a multiple MTANN (Multi-MTANN). The Multi-MTANN consists of plural MTANNs that are arranged in parallel. Each MTANN is trained by using the same nodules, but with a different type of non-nodule. Each MTANN acts as an expert for a specific type of non-nodule, e.g., five different MTANNs were trained to distinguish nodules from various-sized vessels; four other MTANNs were applied to eliminate some other opacities. The outputs of the MTANNs were combined by using the logical AND operation such that each of the trained MTANNs eliminated none of the nodules, but removed the specific type of non-nodule with which the MTANN was trained, and thus removed various types of non-nodules. The Multi-MTANN consisting of nine MTANNs was trained with 10 typical nodules and 10 non-nodules representing each of nine different non-nodule types (90 training non-nodules overall) in a training set. The trained Multi-MTANN was applied to the reduction of false positives reported by our current computerized scheme for lung nodule detection based on a database of 63 low-dose CT scans (1765 sections), which contained 71 confirmed nodules including 66 biopsy-confirmed primary cancers, from a lung cancer screening program. The Multi-MTANN was applied to 58 true positives (nodules from 54 patients) and 1726 false positives (non-nodules) reported by our current scheme in a validation test; these were different from the training set. The results indicated that 83% (1424/1726) of non-nodules were removed with a reduction of one true positive (nodule), i.e., a classification sensitivity of 98.3% (57 of 58 nodules). By using the Multi-MTANN, the false-positive rate of our current scheme was improved from 0.98 to 0.18 false positives per section (from 27.4 to 4.8 per patient) at an overall sensitivity of 80.3% (57/71).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号