共查询到20条相似文献,搜索用时 15 毫秒
1.
Differentiation between Benign and Malignant Solid Thyroid Nodules Using an US Classification System
Young Hun Lee Dong Wook Kim Hyun Sin In Ji Sung Park Sang Hyo Kim Jae Wook Eom Bomi Kim Eun Joo Lee Myung Ho Rho 《Korean journal of radiology》2011,12(5):559-567
Objective
To evaluate the diagnostic accuracy of a new ultrasound (US) classification system for differentiating between benign and malignant solid thyroid nodules.Materials and Methods
In this study, we enrolled 191 consecutive patients who received real-time US and subsequent US diagnoses for solid thyroid nodules, and underwent US-guided fine-needle aspiration. Each thyroid nodule was prospectively classified into 1 of 5 diagnostic categories by real-time US: "malignant," "suspicious for malignancy," "borderline," "probably benign," and "benign". We evaluated the diagnostic accuracy of thyroid US and the cut-off US criteria by comparing the US diagnoses of thyroid nodules with cytopathologic results.Results
Of the 191 solid nodules, 103 were subjected to thyroid surgery. US categories for these 191 nodules were malignant (n = 52), suspicious for malignancy (n = 16), borderline (n = 23), probably benign (n = 18), and benign (n = 82). A receiver-operating characteristic curve analysis revealed that the US diagnosis for solid thyroid nodules using the 5-category US classification system was very good. The sensitivity, specificity, positive and negative predictive values, and accuracy of US diagnosis were 86%, 95%, 91%, 92%, and 92%, respectively, when benign, probably benign, and borderline categories were collectively classified as benign (negative).Conclusion
The diagnostic accuracy of thyroid US for solid thyroid nodules is high when the above-mentioned US classification system is applied. 相似文献2.
Objective
To seek for the ultrasound (US) findings of partially cystic thyroid nodules that are associated with malignancy.Materials and Methods
We reviewed the US characteristics of 22 surgically confirmed partially cystic papillary carcinomas, and compared them with those of 80 benign partially cystic nodules. The review cases were selected in a random order from a total of 1029 partially cystic nodules that were diagnosed with an US-guided fine needle aspiration biopsy over a period of 8 years (June 2003 to October 2010) at our institution.Results
In partially cystic thyroid nodules, a taller-than-wide shape (100%, p < 0.001) and spiculated or microlobulated margin (58.3%, p = 0.003) were significantly associated with malignancy. In terms of internal solid portion of the nodule, eccentric configuration (68.0%, p < 0.001), non-smooth margin (81.3%, p < 0.001), hypoechogenecity (30.0%, p < 0.042), and microcalcification (89.5%, p < 0.001) were more frequently demonstrated in malignant nodules than benign ones.Conclusion
In partially cystic thyroid nodules, understanding the characteristics of US findings is important to make a precise diagnosis of malignant nodules. 相似文献3.
Eun Sun Lee Ji-hoon Kim Dong Gyu Na Jin Chul Paeng Hye Sook Min Seung Hong Choi Chul Ho Sohn Ki-Hyun Chang 《Korean journal of radiology》2013,14(4):643-652
Objective
To retrospectively evaluate the risk of thyroid cancer in patients with hyperfunctioning thyroid nodules through ultrasonographic-pathologic analysis.Materials and Methods
Institutional review board approval was obtained and informed consent was waived. From 2003 to 2007, 107 patients consecutively presented with hot spots on thyroid scans and low serum thyroid-stimulating hormone levels. Among them, 32 patients who had undergone thyroid ultrasonography were analyzed in this study. Thyroid nodules depicted on ultrasonography were classified based on size and categorized as benign, indeterminate, or suspicious malignant nodules according to ultrasonographic findings. The thyroid nodules were determined as either hyperfunctioning or coexisting nodules and were then correlated with pathologic results.Results
In 32 patients, 42 hyperfunctioning nodules (mean number per patient, 1.31; range, 1-6) were observed on thyroid scans and 68 coexisting nodules (mean, 2.13; range, 0-7) were observed on ultrasonography. Twenty-five patients (78.1%) had at least one hyperfunctioning (n = 17, 53.1%) or coexisting (n = 16, 50.0%) nodule that showed a suspicious malignant feature larger than 5 mm (n = 8, 25.0%), or an indeterminate feature 1 cm or greater (n = 20, 62.5%) in diameter, which could have been indicated by using fine needle aspiration (FNA). Seven patients were proven to have 11 thyroid cancers in 3 hyperfunctioning and 8 coexisting nodules. All of these had at least one thyroid cancer, which could have been indicated by using FNA. The estimated minimal risk of thyroid cancer was 6.5% (7/107).Conclusion
Patients with hyperfunctioning nodules may not be safe from thyroid cancer because hyperfunctioning nodules can coexist with thyroid cancer nodules. To screen out these cancers, ultrasonography should be performed. 相似文献4.
Hyun Su Choi Sung Hoon Kim Sonya Youngju Park Hye Lim Park Ye Young Seo Woo Hee Choi 《Nuclear Medicine and Molecular Imaging》2014,48(1):63-71
Purpose
The purpose of this study was to identify the frequency and possible cause of diffuse intrathoracic uptake on post-therapy I-131 scans in thyroid cancer patients.Methods
We retrospectively reviewed 781 post-therapy scans of 755 thyroid cancer patients who underwent total thyroidectomy and radioactive iodine therapy between January and December 2010. Diffuse intrathoracic uptake on post-therapy scans was examined, and clinical patient characteristics including sex, age, regimen for thyroid-stimulating hormone (TSH) stimulation (thyroid hormone withdrawal or recombinant human TSH injection), TSH, thyroglobulin (Tg) and anti-thyroglobulin antibody (anti-Tg Ab) levels, therapeutic dose of radioactive iodine therapy and prior history of radioactive iodine therapy were recorded.Scan findings were correlated with chest CT, chest radiographs, laboratory tests and/or clinical status. Diffuse intrathoracic uptake without evidence of pathologic condition was categorized as indeterminate. The association between clinical characteristics and intrathoracic uptake were analyzed for negative intrathoracic uptake and indeterminate uptake groups.Results
Diffuse intrathoracic uptake on post-therapy scans was demonstrated in 39 out of 755 (5.2 %) patients, among which 3 were confirmed as lung metastasis. The 14 patients that showed high Tg or anti-Tg Ab levels were considered to be at risk of having undetected micrometastasis on other imaging modalities. The remaining 22 were indeterminate (2.9 %).Upon comparison of negative intrathoracic uptake and indeterminate uptake groups, TSH stimulation by thyroid hormone withdrawal was shown to be significantly correlated with diffuse intrathoracic uptake (p < 0.05).Conclusion
The frequency of diffuse intrathoracic uptake on post-therapy scans was 5.2 % and could be seen in thyroid cancer patients with underlying lung metastasis as well as those without definite pathologic condition. In the latter, there was a higher frequency for diffusely increased intrathoracic uptake in those who underwent thyroid hormone withdrawal rather than recombinant human TSH injection. 相似文献5.
Hyukjin Yoon Sung Hoon Kim Joo Hyun O Ye Young Seo Yeongjoo Lee Hyoungwoo Kim Jiyoung Ryu 《Nuclear Medicine and Molecular Imaging》2015,49(4):276-283
Objective
The aim of this study was to evaluate the value of thyroglobulin (Tg) kinetics during preparation of radioiodine ablation for prediction of initial radioiodine ablation failure in thyroid cancer patients.Methods
Thyroid cancer patients after total thyroidectomy who underwent radioiodine ablation with 3–4 weeks of hormone withdrawal between May 2011 and January 2012 were included. Consecutive serum Tg levels 5–10 days before ablation (Tg1) and on the day of ablation (Tg2) were obtained. The difference between Tg1 and Tg2 (ΔTg), daily change rate of Tg (ΔTg/day) and Tg doubling time (Tg-DT) were calculated. Success of initial ablation was determined by the results of the follow-up ultrasonography, diagnostic radioiodine scan and stimulated Tg level after 6 to 20 months.Results
A total of 143 patients were included. Failed ablation was reported in 52 patients. Tg2 higher than 5.6 ng/ml and Tg-DT shorter than 4.2 days were significantly related to a high risk of ablation failure. ΔTg and ΔTg/day did not show significant correlation with ablation failure.Conclusions
Thyroglobulin kinetics on consecutive blood sampling during hormone withdrawal may be helpful in predicting patients with higher risk of treatment failure of initial radioiodine ablation therapy in thyroid cancer patients. 相似文献6.
Young Jun Choi Jung Hwan Baek Min Ji Hong Jeong Hyun Lee 《Korean journal of radiology》2015,16(3):560-565
Objective
Thyroid nodule measurement using ultrasonography (US) is widely performed in various clinical scenarios. The purpose of this study was to evaluate inter-observer variation in US measurement of the volume and maximum diameter of thyroid nodules.Materials and Methods
This retrospective study included 73 consecutive patients with 85 well-defined thyroid nodules greater than 1 cm in their maximum diameter. US examinations were independently performed by using standardized measurement methods, conducted by two clinically experienced thyroid radiologists. The maximum nodule diameter and nodule volume, calculated from nodule diameters using the ellipsoid formula, were obtained by each reader. Inter-observer variations in volume and maximum diameter were determined using 95% Bland-Altman limits of agreement. The degree of inter-observer variations in volumes and the maximum diameters were compared using the Student''s t test, between nodules < 2 cm in maximum diameter and those with ≥ 2 cm.Results
The mean inter-observer difference in measuring the nodule volume was -1.6%, in terms of percentage of the nodule volume, and the 95% limit of agreement was ± 13.1%. For maximum nodule diameter, the mean inter-observer difference was -0.6%, in terms of percentage of the nodule diameter, and the 95% limit of agreement was ± 7.3%. Inter-observer variation in volume was greater in nodules of < 2 cm in maximum diameter, compared to the larger nodules (p = 0.035). However, no statistically significant difference was noted between the two groups regarding maximum nodule diameters (p = 0.511).Conclusion
Any differences smaller than 13.1% and 7.3% in volume and maximum diameter, respectively, measured by using US for well-defined thyroid nodules of > 1 cm should not be considered as a real change in size. 相似文献7.
Nami Choi Won-Jin Moon Hahn Young Kim Hong Gee Roh Jin Woo Choi 《Korean journal of radiology》2012,13(3):275-282
Objective
To determine the prevalence of thyroid incidentalomas detected by time-resolved magnetic resonance angiography (TRMRA) and to evaluate their clinical significance by using an ultrasonographic (US) and cytologic correlation.Materials and Methods
We retrospectively reviewed 2010 consecutive TRMRA examinations performed at our institution between August 2006 and April 2010. The TRMRA findings of thyroid incidentalomas were analyzed according to location, size, as well as vascularity, and were correlated with the US findings and cytologic results. Each nodule was classified as suspiciously malignant, indeterminate or probably benign according to the US criteria recommended by the Korean Society of Thyroid Radiology.Results
A total of 102 incidentalomas were detected in 90 of 2010 patients (5%). TRMRA showed homogenous hypervascularity in 48 (47%), inhomogeneous hypervascularity in 46 (45%), and hypovascularity in 8 (8%) thyroid nodules. At follow-up study, out of 26 patients with 30 incidentalomas on TRMRA, 27 nodules were identified on US. Of the 27 nodules, 24 (89%) nodule were classified as indeterminate, two (7%) as probably benign, and one (4%) as suspiciously malignant. Among the 16 nodules with available cytopathologic results, 14 (82%) were benign, one (6%) was indeterminate, and one (6%) was malignant.Conclusion
Thyroid incidentalomas are found in 5% of TRMRA examinations. Although their presence does not necessarily indicate malignancy, nonspecific findings of detected incidentalomas on TRMRA require further evaluation by US. 相似文献8.
Objective:
The aim of our study was to assess the performance of acoustic radiation force impulse (ARFI) imaging to differentiate benign from malignant thyroid nodules.Methods:
182 patients who needed thyroid surgery were examined. All patients and 50 healthy volunteers underwent ARFI sonoelastography, which quantitatively analysed the elasticity and hardness of the nodule''s centre and periphery.Results:
ARFI values showed a statistical significance between malignant nodules and benign nodules and common thyroid parenchyma, in both the centre and periphery of nodules (p < 0.01). There was no significant difference between benign nodules and common thyroid parenchyma in either the nodule''s centre or periphery (p > 0.05). There was no significant difference between the nodule''s centre and periphery of the elastic parameters in both the benign and malignant nodules. There was a statistically significant difference among the two areas (the central group and the peripheral group) under the receiver operating characteristic curve, and the optimal model was the peripheral group. For differentiation of malignant from benign nodules, the sensitivity and specificity were 96.3% and 96.2%, respectively, when 2.545 m s−1 was chosen as a cut-off value in the peripheral group.Conclusion:
ARFI imaging may be helpful to differentiate benign nodules from malignant thyroid nodules. The selecting measurement position is important in ARFI imaging, and it has good diagnostic value in clinical applications.Advances in knowledge:
This study shows the diagnostic contribution of ARFI imaging in thyroid lesions.Thyroid cancer is the most common endocrine malignancy, and its incidence has increased in recent years.1 It comprises different clinical and histological features in respect to different treatments.2 The diagnostic method for thyroid cancer has very quickly progressed in recent years, but the pre-operative misdiagnosis rate is 40–70%.A newer ultrasound elastography technique called acoustic radiation force impulse (ARFI), which is performed under direct visual guidance, has recently been verified to measure the stiffness of many tissues in vivo, for example in the liver.3,4 In our study, we investigated the mechanical properties of focal thyroid disease with ARFI. The purposes of this study were to assess the effectiveness of ARFI quantification in the diagnosis of focal thyroid nodules and differentiation of benign from malignant thyroid lesions by quantification of their stiffness. 相似文献9.
Sehun Choi Chang Ju Na Jeonghun Kim Yeon-Hee Han Hee-Kwon Kim Hwan-Jeong Jeong Myung-Hee Sohn Seok Tae Lim 《Nuclear Medicine and Molecular Imaging》2015,49(2):115-121
Purpose
High-dose radioiodine treatment (HD-RIT) after injection of recombinant human thyroid stimulating hormone (rh-TSH) has become widely used. This study compared the therapeutic efficacy of HD-RIT and clinical parameters between rh-TSH supplement and thyroid hormone withdrawal (THW) after total thyroidectomy in patients with differentiated thyroid cancer.Methods
We retrospectively reviewed 266 patients (47 male and 219 female; age, 49.0 ± 10.9 years) with differentiated thyroid cancer detected from September 2011 to September 2012. Patients comprised THW (217, 81.6 %) and rh-TSH (49, 18.4 %). Inclusion criteria were: first HD-RIT; any TN stage; absence of distant metastasis. To evaluate the complete ablation of the remnant thyroid tissue or metastasis, we reviewed stimulated serum thyroglobulin (sTg), I-123 whole-body scan (RxWBS) on T4 off-state, and thyroid ultrasonography (US) or [F-18]-fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) 6–8 months after HD-RIT. We defined a complete ablation state when all three of the follow-up conditions were satisfied; <2.0 ng/ml of the sTg, I-123 RxWBS (−), and thyroid US or F-18 FDG PET/CT (−). If one of the three was positive, ablation was considered incomplete. We also compared various clinical biomarkers (body weight, body mass index, liver and kidney function) between THW and rh-TSH groups.Results
The rates of complete ablation were 73.7 % (160/217) for the THW group and 73.5 % (36/49) for the rh-TSH group. There was no significant difference between the two groups (p = 0.970). The follow-up aspartate transaminase (p = 0.001) and alanine transaminase (p = 0.001) were significantly higher in the THW group. The renal function parameters of blood urea nitrogen (p = 0.001) and creatinine (p = 0.005) tended to increase in the THW group. The change of body weight was + Δ0.96 (±1.9) kg for the THW group and was decreased by -Δ1.39 (±1.5) kg for the rh-TSH group. The change of body mass index was 0.4 (±0.7) kg/m2 in the THW group and was decreased by −0.6 (±0.6) kg/m2 in the rh-TSH group.Conclusions
Consistent with previous studies, the rates of complete ablation between the THW and rh-TSH groups were not significantly different. The clinical parameters, as we mentioned above, were elevated for THW group but were irrelevant for the rh-TSH group. The findings favor HD-RIT after rh-TSH, especially for patients with chronic liver and kidney disease. 相似文献10.
Sung Hun Kim Chang Suk Park So Lyung Jung Bong Joo Kang Jee Young Kim Jae Jung Choi Ye Il Kim Jin Kyung Oh Jung Suk Oh Hanna Kim Seung Hee Jeong Hyeon Woo Yim 《Korean journal of radiology》2010,11(2):149-155
Objective
To evaluate the interobserver variability and performance in the interpretation of ultrasonographic (US) findings of thyroid nodules.Materials and Methods
72 malignant nodules and 61 benign nodules were enrolled as part of this study. Five faculty radiologists and four residents independently performed a retrospective analysis of the US images. The observers received one training session after the first interpretation and then performed a secondary interpretation. Agreement was analyzed by Cohen''s kappa statistic. Degree of performance was analyzed using receiver operating characteristic (ROC) curves.Results
Agreement between the faculties was fair-to-good for all criteria; however, between residents, agreement was poor-to-fair. The area under the ROC curves was 0.72, 0.62, and 0.60 for the faculties, senior residents, and junior residents, respectively. There was a significant difference in performance between the faculties and the residents (p < 0.05). There was a significant increase in the agreement for some criteria in the faculties and the senior residents after the training session, but no significant increase in the junior residents.Conclusion
Independent reporting of thyroid US performed by residents is undesirable. A continuous and specialized resident training is essential to enhance the degree of agreement and performance. 相似文献11.
Oktay Algin Efnan Algin Gokhan Gokalp Gokhan Ocako?lu Cüneyt Erdo?an Ozlem Saraydaroglu Ercan Tuncel 《Korean journal of radiology》2010,11(6):594-602
Objective
To evaluate the usage of duplex power Doppler ultrasound (PDUS) for the differentiation of benign and malignant thyroid nodules.Materials and Methods
We prospectively examined 77 thyroid nodules in 60 patients undergoing ultrasound-guided fine needle aspiration biopsy (FNAB). Each nodule was described according to size, inner structure, borders, parenchymal echogenicity, peripheral halo formation, and the presence of calcification (B-mode ultrasound findings). Vascularity as determined by PDUS imaging was defined as non-vascular, peripheral, central, or of mixed type. For each nodule, the pulsatility index (PI) and resistive index (RI) values were obtained. Results of FNAB and surgical pathological examination (if available) were used as a proof of final diagnosis to categorize all nodules as benign or malignant. A receiver operating characteristic (ROC) curve analysis was performed to establish cut-off, sensitivity, and specificity values associated with RI-PI values.Results
A significant relationship was observed between malignancy and irregular margins, microcalcifications, and hypoechogenicity on ultrasound examination (p < 0.05). The pattern of vascularity as determined by PDUS analysis was not a statistically significant criterion to suggest benign or malignant disease in this study (p > 0.05). The central, peripheral, and mean RI-PI values were higher in malignant nodules when compared to the other cytologies (p < 0.05).Conclusion
Vascularity is not a useful parameter for distinguishing malignant from benign thyroid nodules. However, RI and PI values are useful in distinguishing malignant from benign thyroid nodules. 相似文献12.
Objective
The aim of the study was to compare the diagnostic performances of F-18 sodium fluoride positron emission tomography/computed tomography (bone PET/CT) and bone scintigraphy (BS) for the detection of thyroid cancer bone metastasis.Materials and Methods
We retrospectively enrolled 6 thyroid cancer patients (age = 44.7 ± 9.8 years, M:F = 1:5, papillary:follicular = 2:4) with suspected bone metastatic lesions in the whole body iodine scintigraphy or BS, who subsequently underwent bone PET/CT. Pathologic diagnosis was conducted for 4 lesions of 4 patients.Results
Of the 17 suspected bone lesions, 10 were metastatic and 7 benign. Compared to BS, bone PET/CT exhibited superior sensitivity (10/10 = 100% vs. 2/10 = 20%, p = 0.008), and accuracy (14/17 = 82.4% vs. 7/17 = 41.2%, p < 0.025). The specificity (4/7 = 57.1%) of bone PET/CT was not significantly different from that of BS (5/7 = 71.4%, p > 0.05).Conclusion
Bone PET/CT may be more sensitive and accurate than BS for the detection of thyroid cancer bone metastasis. 相似文献13.
Ari Chong Ho-Chun Song Jung-Joon Min Shin Young Jeong Jung-Min Ha Jahae Kim Su-Ung Yoo Jong-Ryool Oh Hee-Seung Bom 《Nuclear Medicine and Molecular Imaging》2010,44(4):273-281
Purpose
The purpose of this study is to compare post-therapy third day and seventh day I-131 whole body scans (3DWBS and 7DWBS) in detecting lung or bone metastasis from well-differentiated thyroid cancer.Materials and Methods
We enrolled 52 patients with lung or bone metastasis out of 1,152 patients who were treated with high-dose I-131 therapy from January 2008 to June 2009. All patients underwent 3DWBS and 7DWBS. I-131 avidity was classified into three grades: no uptake, suspicious for uptake, and definite uptake. We compared the presence and grades of metastatic lesions on each scan. We categorized all cases into three groups based on I-131 uptake on each scan and compared several clinical parameters including FDG uptake and thyroglobulin (Tg) level among the groups.Results
Sixty metastatic cases from 52 patients (45 lung and 15 bone metastases) were included. In 35 cases, I-131-avid metastatic lesions were detected by both 3DWBS and 7DWBS (group A). In 15 cases, metastatic lesions were missed on 3DWBS but detected on 7DWBS (group B). In 10 cases, I-131 uptake was not detected on either 3DWBS or 7DWBS (group C). Ten of 45 cases (22.2%) of lung metastasis that were negative on 3DWBS were detected on 7DWBS (p = 0.002). Five of 15 cases (33.3%) of bone metastasis that were negative on 3DWBS were detected on 7DWBS (p = 0.0625). The serum Tg level (TSH stimulated) was significantly different among groups A, B, and C (p = 0.0030). However, after exclusion of cases without a history of I-131 therapy, there was no significant difference in serum Tg level among the groups (p = 0.2330). The number of cases with a prior history of metastasis was higher in group A than in group B (p = 0.0069). However, there was no significant difference in prior history of metastasis between groups A and C (p = 0.8107).Conclusion
7DWBS showed more lung or bone metastatic lesions than 3DWBS. After high-dose I-131 therapy, 7DWBS should be considered regardless of the results of the 3DWBS for the diagnosis of lung or bone metastasis from well-differentiated thyroid cancer. 相似文献14.
Seung Hyun Son Sang-Woo Lee Ji-hoon Jung Choon-Young Kim Do-Hoon Kim Shin Young Jeong Byeong-Cheol Ahn Jaetae Lee 《Nuclear Medicine and Molecular Imaging》2015,49(4):268-275
Purpose
To determine the optimal levels of thyroid-stimulating hormone (TSH) levels after administration of recombinant human TSH (rhTSH) to patients with differentiated thyroid cancer (DTC), we have analyzed the clinical parameters that affected the degree of the increase in serum levels of TSH.Methods
We retrospectively analyzed 276 patients with differentiated thyroid cancer (DTC), post-thyroidectomy and remnant ablation. Pearson’s correlation coefficient test was used to evaluate the correlation between serum levels of TSH after rhTSH stimulation and various clinical factors, including age, sex, height, weight, body mass index (BMI), body surface area (BSA), serum blood urea nitrogen, creatinine, and estimated glomerular filtration rate (GFR). Linear regression analysis was used to determine the predictors of the degree of increase in serum TSH level after rhTSH stimulation.Results
After the rhTSH injections, all subjects achieved TSH levels of >30 μU/mL, with a mean of 203.8 ± 83.4 μU/mL. On univariate analysis, age (r = 0.255) and serum creatinine (r = 0.169) level were positive predictors for higher levels of serum TSH after rhTSH stimulation, while weight (r = –0.239), BMI (r = –0.223), BSA (r = –0.217), and estimated GFR (r = –0.199) were negative predictors. Multiple linear regression analysis revealed that serum creatinine was the most powerful independent predictor for serum levels of TSH, followed by age, BSA, and BMI.Conclusions
An increment in serum TSH after rhTSH stimulation was significantly affected by age, BSA, BMI, and creatinine, with creatinine being the most powerful predictor. By understanding the difference in the increased levels of TSH in various subjects, their dose of rhTSH can be adjusted during scheduling for radioiodine ablation, or during follow-up (recurrence surveillance) after surgery and ablation. 相似文献15.
Yeon-Hee Han Seok Tae Lim Kuk-No Yun Sung Kyun Yim Dong Wook Kim Hwan-Jeong Jeong Myung-Hee Sohn 《Nuclear Medicine and Molecular Imaging》2012,46(2):89-94
Purpose
An elevated thyroid stimulating hormone level (TSH) is essential to stimulate the uptake of radioiodine into thyroid remnants and metastases of thyroid cancer when a patient undergoes high-dose radioiodine therapy. Nowadays, recombinant human thyroid stimulating hormone (rh-TSH) is increasingly used instead of the classic method of thyroid hormone withdrawal (THW). However, beyond the therapeutic effects, clinical differences between the two methods have not yet been clearly demonstrated. The aim of this work was to investigate the effects of the two methods, especially on liver function.Methods
We identified 143 evaluable patients who were further divided into two groups: THW and rh-TSH. We first reviewed the aspartate aminotransferase (AST) and alanine aminotransferase (ALT) levels, which were measured during the admission period for total thyroidectomy. We called these liver enzyme levels “base AST” and “base ALT.” We also assessed other chemistry profiles, including AST, ALT, total cholesterol, LDL cholesterol, alkaline phosphatase (ALP), total bilirubin (TB), and triglyceride (TG), which were measured on admission day for high-dose radioiodine therapy. We called these liver enzyme levels “follow-up AST” and “follow-up ALT.” We compared the changes in base and follow-up liver enzyme levels and the other chemistry profiles between the two groups.Results
The base AST and base ALT levels of the two groups were within normal range, and there was no significant difference between the two groups. In contrast to these base liver enzyme levels, follow-up liver enzyme levels between the two groups showed significant differences. Patients in the THW group had higher follow-up AST and ALT levels than did the rh-TSH group. Patients in the THW group also had higher levels of total cholesterol and LDL cholesterol than did the patients in the rh-TSH group. However there were no statistically significant differences in ALP, total bilirubin, and triglyceride levels between the two groups.Conclusions
In this retrospective analysis of liver function, the use of rh-TSH for high-dose radioiodine therapy had less of an effect on liver function and cholesterol levels than dose thyroid hormone withdrawal. This suggests that rh-TSH can be used effectively and safely especially for patients with metabolic syndrome. 相似文献16.
Dong Wook Kim Auh Whan Park Eun Joo Lee Hye Jung Choo Sang Hyo Kim Sang Hyub Lee Jae Wook Eom 《Korean journal of radiology》2009,10(5):435-440
Objective
The aim of this study was to determine the efficacy of the use of an ultrasound-guided fine-needle aspiration biopsy (US-FNAB) to diagnose thyroid nodules smaller than 5 mm in the maximum diameter and to evaluate pathological findings of small thyroid malignancies.Materials and Methods
From May 2007 to April 2008, we evaluated the findings of US-FNABs of small thyroid nodules less than 5 mm in the maximum diameter. The cytopathological findings were retrospectively reviewed and the diagnostic performance of the use of an US-FNAB was examined in all patients.Results
Of 201 small thyroid nodules in 180 patients, there were 162 adequate specimens (81%). Among 180 patients, 75 patients underwent thyroid surgery and 50 malignant and 33 benign nodules were identified based on a pathological examination. All small malignant thyroid nodules were identified as papillary thyroid microcarcinomas (PTMCs). There were 34 (55%) true positive, 0 (0%) false positive, 23 (37%) true negative and five (8%) false negative results for malignancy after performing a first US-FNAB in 62 surgically confirmed nodules. The sensitivity (87%), specificity (100%), positive predictive value (100%), negative predictive value (82%), accuracy (92%), false positive rate (0%) and false negative rate (8%) for an US-FNAB were determined. In 23 patients with a primary PTMC, capsular invasion (9%, 2 of 23), a perithyroidal lymph node metastasis (30%, 7 of 23), the rate of multifocality (9%, 2 of 23) and bilaterality (4%, 1 of 23) were also determined.Conclusion
An US-FNAB of thyroid nodules smaller than 5 mm in the maximum diameter is an effective diagnostic procedure. 相似文献17.
Hee-Sung Song Su Jin Lee Seok-Ho Yoon Jandee Lee Euy-Young Soh Young-Sil An Joon-Kee Yoon 《Nuclear Medicine and Molecular Imaging》2011,45(3):197-202
Purpose
We investigated the clinical significance of diffuse uptake in remaining thyroid after unilateral lobectomy for thyroid cancer.Methods
A total of 144 thyroid cancer patients who underwent 18F-FDG PET/CT after lobectomy were enrolled in the present study. The PET/CT images were evaluated for the presence of diffuse 18F-FDG uptake with maximum SUV (SUVmax) >2.0 in the residual thyroid and placed into one of two groups: with diffuse uptake and without diffuse uptake group. Clinical, laboratory, and PET/CT parameters in both groups were compared. Correlations between SUVmax of thyroid and available parameters were analyzed.Results
Forty-two of 144 patients (29.2%) had diffuse thyroid uptake (mean SUVmax: 3.2 ± 1.1). All patients with diffuse uptake and 96 (94.1%) without diffuse uptake were receiving thyroxine therapy (P = 0.09). Thyroid function tests showed that most patients were euthyroid status (78.6 vs. 85.3%, P = 0.36). TgAb levels were significantly higher in patients with diffuse uptake (338.0 ± 664.6 vs. 57.3 ± 46.4, P < 0.0001). Mean attenuation values in the diffuse uptake group were significantly lower (72.2 ± 15. vs. 97.0 ± 16.0, P < 0.0001). An inverse correlation was found between SUVmax and mean attenuation values of residual thyroid in all patients (r = −0.57, P < 0.0001) and subgroup with diffuse uptake (r = −0.31, P < 0.05).Conclusion
In this study, diffuse 18F-FDG uptake in the residual thyroid after unilateral lobectomy was a relatively frequent finding and may be associated with chronic thyroiditis. This uptake is not influenced by thyroid status or thyroxine therapy. The 18F-FDG uptake is inversely correlated with mean attenuation value of thyroid. 相似文献18.
Sun Jin Lee So Lyung Jung Bum Soo Kim Kook Jin Ahn Hyun Seok Choi Dong Jun Lim Min Hee Kim Ja Seong Bae Min Sik Kim Chan Kwon Jung Se Min Chong 《Korean journal of radiology》2014,15(6):817-826
Objective
To evaluate the efficacy of radiofrequency ablation (RFA) in the treatment of loco-regional, recurrent, and well-differentiated thyroid carcinoma.Materials and Methods
Thirty-five recurrent well-differentiated thyroid carcinomas (RTC) in 32 patients were treated with RFA, between March 2008 and October 2011. RTCs were detected by regular follow-up ultrasound and confirmed by biopsy. All patients had fewer than 3 RTCs in the neck and were at high surgical risk or refused to undergo repeated surgery. Average number of RFA sessions were 1.3 (range 1-3). Post-RFA biopsy and ultrasound were performed. The mean follow-up period was 30 months. Pre- and post-RFA serum thyroglobulin values were evaluated.Results
Thirty-one patients with 33 RTCs were treated with RFA only, whereas 1 patient with 2 RTCs was treated with RFA followed by surgery. At the last follow-up ultrasound, 31 (94%) of the 33 RTCs treated with RFA alone completely disappeared and the remaining 2 (6%) RTCs showed decreased volume. The largest diameter and volume of the 33 RTCs were markedly decreased by 93.2% (from 8.1 ± 3.4 mm to 0.6 ± 1.8 mm, p < 0.001) and 96.4% (from 173.9 ± 198.7 mm3 to 6.2 ± 27.9 mm3, p < 0.001), respectively. Twenty of the 21 RTCs evaluated with post-RFA biopsies (95%) were negative for malignancy. One (5%) showed remaining tumor that was removed surgically. The serum thyroglobulin was decreased in 19 of 26 patients (73%). Voice change developed immediately after RFA in 6 patients (19%) and was spontaneously recovered in 5 patients (83%).Conclusion
Radiofrequency ablation can be effective in treating loco-regional, recurrent, and well-differentiated thyroid carcinoma in patients at high surgical risk. 相似文献19.
Seog Gyun Kim Jin Chul Paeng Jae Seon Eo Hye Kyung Shim Keon Wook Kang June-Key Chung Myung Chul Lee Dong Soo Lee 《Nuclear Medicine and Molecular Imaging》2010,44(4):267-272
Purpose
With the recent increase in incidence of thyroid cancer, non-hospitalized low-dose (NH-LD) radioiodine treatment (RIT) has also increased rapidly. The radioactivity limit that is allowed to be administered without hospitalization depends on individual calculation, based partly on patients’ behavior. In this study, Korean patients’ behavior in relation to radiation safety in NHLD RIT was surveyed.Methods
A total of 218 patients who underwent NH-LD RIT of 1.1 GBq 131I in a single center were surveyed. The patients underwent RIT with a standard protocol and the survey was performed by interview when they visited subsequently for a whole-body scan. The survey questionnaire included three parts of questions: general information, behavior relating to isolation during RIT, and awareness of radiation safety.Results
After administration of radioiodine, 40% of patients who returned home used mass transportation, and another 47% went home by taxi or in car driven by another person. Isolation at home was generally sufficient. However, 7% of patients did not stay in a separate room. Among the 218 patients, 34% did not go home and chose self-isolation away from home, mostly due to concerns about radiation safety of family members. However, the places were mostly public places, including hotels, resorts, and hospitals. About half of the patients replied that access to radiation safety information was not easy and their awareness of radiation safety was not satisfactory. As a result, 45% of patients wanted hospitalized RIT.Conclusions
In many countries, including Korea, RIT is continuously increasing. Considering the radiation safety of patients’ family members or the public and the convenience of patients, the pretreatment education of patients should be enhanced. In addition, the hospitalization of patients having low-dose therapy is recommended to be seriously considered and expanded, with the expansion of dedicated treatment facilities. 相似文献20.
Ik Dong Yoo Sung Hoon Kim Ye Young Seo Jin Kyoung Oh Joo Hyun O Soo Kyo Chung 《Nuclear Medicine and Molecular Imaging》2012,46(1):34-40