首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The present study was undertaken to assess the pulmonary functions in fertiliser and chemical industry workers of Kerala. Pulmonary function test was performed with Vitalograph Compact-II spirometer. Exposure to different chemicals, noxious gases and particulate matter of fertiliser and chemical industry was injurious to the normal pulmonary function. Significant decline in lung volumes, viz. FVC, FEV1, FEV1/FVC% (P < 0.01) and flow rates, viz. FEF25-75%, FEF0.2-1.2, FEF25%, FEF50%, FEF75% (P < 0.01) among non-smokers and smokers than that of normal controls was observed. The findings of this study also suggest that with increased duration of exposure to industrial pollutants, lung volumes and flow rates were significantly reduced in workers.  相似文献   

2.
Lung function development was studied in a cohort of Indian men (n = 31) and women (n = 36), over a period of four years during late adolescence and early adulthood. Forced expiratory spirograms and peak expiratory flow rates were recorded at intervals of approximately two years. All volumes and flow rates were higher in men, but volume adjusted flow rates were higher in women. Forced vital capacity (FVC) forced expiratory volume in one second (FEV1) and peak expiratory flow (PEF) were significantly higher in men even after standardizing for age, height and weight. Height and PEF increased significantly in men and women over the four years. Volumes showed a greater increase whereas flow rates and volume adjusted flow rates showed a greater decrease in men. The decline in the forced expiratory flow in the middle half of the FVC (FEF 25-75%) was significantly less in women. These results suggest that although lung size is greater in men, small airway dynamics may be better in young women.  相似文献   

3.
The purpose of the study was to investigate the effects of one night's sleep deprivation on the cardiorespiratory responses to exercise during the follicular and luteal phases of the menstrual cycle. We have studied nine, healthy females aged 24-35 years with regular menstrual cycles. Each subject performed spirometric tests at rest and then an incremental exercise testing during 11-13 days of follicular phase and 22-24 days of luteal phase following one normal night's sleep or one night's sleep loss. Compared with resting values exercise produced significant increases in cardiorespiratory variables including oxygen uptake (VO2), carbon dioxide production (VCO2), tidal volume (VT), respiratory rate (RR), minute ventilation (VE), systolic blood pressure, heart rate (HR) and respiratory quotient (R). However, it did not alter significantly diastolic blood pressure, end-tidal PO2 (PETO2), end-tidal PCO2 (PETCO2) and arterial oxygen saturation (SaO2). Spirometric variables which include forced vital capacity (FVC), forced expiratory volume in one s (FEV1), FEV1/FVC%, forced expiratory volume in three s (FEV3), forced expired flow from 25-75% of FVC (FEF 25-75%), forced expired flow at 25% of FVC (FEF 25%), forced expired flow at 50% of FVC (FEF 50%), forced expired flow at 75% of FVC (FEF 75%), forced expired flow from 75-85% of FVC (FEF 75-85%), peak expiratory flow (PEF), expiratory reserve volume (ERV), inspiratory capacity (IC) and maximal voluntary ventilation (MVV) and cardiorespiratory variables were not different between the cycle phases after one normal night's sleep or one night's sleep deprivation. Neither menstrual cycle phase nor sleep deprivation affected spirometric and cardiorespiratory parameters. We suggest that one night's sleep deprivation does not produce alterations in spirometric parameters and cardiorespiratory responses to submaximal incremental exercise during the follicular and luteal phases.  相似文献   

4.
The present study was carried out to assess the lung functions in oral medicated and insulin administered patients with normal controls. 20 subjects were selected as the study group for oral medication (Group I), 20 subjects were selected as the study group for insulin treatment (Group II) and 40 subjects were selected as normal controls. Age group of Group I and Group II were 51.25 +/- 6.28 and 50.8 +/- 6.56 respectively and controls were age and height matched. Seventeen patients of Group I were undergoing treatment for the last 10-20 years and 20 patients in Group II were undergoing treatment for the last 30 years. Only male subjects were selected for the study. Lung function test were carried out with Spirometer (Vitallograph Compact II). A significant reduction in forced expiratory volume/forced vital capacity (FEV1/FVC%) was observed in oral pills used subjects and insulin administered subjects as compared to controls. Significant decrease in forced expiratory flow rate (FEF25-75%) in group I subjects was also observed as compared to controls. Forced mid flow time (FMFT) showed a significant increase in group II in comparison to controls. These changes clearly show the expiratory flow rates are reduced both in orally medicated and insulin administered patients. Increase in FMFT in group I may be due to the reduced respiratory ability to carry out the FVC test along with the side effects of oral medication for diabetes mellitus.  相似文献   

5.
The present study was carried out to assess the lung functions in oral contraceptive administered women. Lung function tests were carried out with Spirometer (Vitallograph Compact II). A significant increase in vital capacity (VC) was observed in these women as compared to normal control. There was also a significant decrease in forced expiratory volume in 1 sec./vital capacity (FEV1/VC%) and forced expiratory volume in 1 sec./forced vital capacity (FEV1/FVC%) among oral contraceptive administered women as compared to controls. Further, a significant increase in peak expiratory flow rate (PEF), reduction in forced expiratory flow rate (FEF75-85%) and FEF75% were observed among oral contraceptive administered women as compared to controls. The increase in VC and PEF might be due to the synthetic form of progesterone (progestins) present in oral contraceptive pills which causes hyperventilatory changes. Synthetic progesterone during luteal phase of menstrual cycle might increase the static and dynamic volumes of lung i.e. VC and PEF. But FEF75% showed a decrease which might be due to the lower neuromuscular coordination during breathing.  相似文献   

6.
Exposure to long term air pollution in the work environment may result in decreased lung functions and various other health problems. A significant occupational hazard to lung functions is experienced by plastic factory workers. The present study is planned to assess the pulmonary functions of workers in the plastic factory where recycling of pastic material was done. These workers were constantly exposed to fumes of various chemicals throughout the day. Thirty one workers of plastic factory were assessed for their pulmonary functions. Parameters were compared with 31 age and sex matched controls not exposed to the same environment. The pulmonary function tests were done using Sibelmed Datospir 120 B portable spirometer. A significant decrease in most of the flow rates (MEF 25%, MEF 50%, MEF 75% and FEF 25-75%) and most of the lung volumes and capacities (FVC, FEV1, VC, TV, ERV, MVV) were observed in the workers. Smoking and duration of exposure were not affecting the lung functions as the non smokers also showed a similar decrement in pulmonary functions. Similarly the workers working for less than 5 years also had decrement in pulmonary functions indicating that their lungs are being affected even if they have worked for one year. Exposure to the organic dust in the work environment should be controlled by adequate engineering measures, complemented by effective personal respiratory protection.  相似文献   

7.
To our knowledge, there is no data on the effect of tiotropium on pulmonary gas exchange in healthy subjects. The aim of this study was to assess the effects of tiotropium on pulmonary diffusing capacity. Twenty-one healthy volunteers were enrolled for a prospective, randomized, double-blind, placebo-controlled study. Spirometric measurements, including pulmonary-diffusing capacity, were obtained before and after inhalation of drug or placebo. There was a significant decrease in forced vital capacity (FVC) and, consequently, an increase in the forced expiratory volume in one second (FEV1) to FVC ratio after placebo inhalation (p < 0.05), but no changes were found for percent-predicted FVC, FEV1, percent-predicted FEV1, percent-predicted forced expiratory flow (FEF25%-75%), percent-predicted peak expiratory flow (PEF), diffusing capacity of the lung for carbon monoxide (DLCO), single-breath alveolar volume (VA) and DLCO/VA ratio when compared with the baseline. Tiotropium inhalation caused a significant increase in FVC, percent-predicted FEV1, FEV1/FVC and percent-predicted FEF25%-75%, although the decrease in DLCO was insignificant (12.4 +/- 0.9 to 11.4 +/- 0.9). In conclusion, tiotropium does not change the pulmonary-diffusing capacity in healthy volunteers.  相似文献   

8.
Progesterone is known to cause hyperventilation and hypercapnia in the luteal phase of a normal menstrual cycle. Viewing this fact lung functions were measured in 71 girls with a mean age of 14.5 years during their follicular and luteal phase of menstrual cycle. Subjects were grouped into I, II and III depending on the age range. Respiratory functions comprising of FVC, FIVC, TLC, RV/TLC, FEV1, FEV1/FVC, FRC, PEFR, FEF 25%, FEF 50%, FEF 75%, PIFR, RAW and KST respectively were performed using Spiro 232 of PK Morgan under standardized laboratory settings. The anthropometric parameters such as height, weight and arm span were also recorded. The majority of pulmonary functions reflect better values in luteal phase as compared with follicular phase however, a statistically significant higher results of FVC, FIVC, FEV1, and TLC were noticed in group I and group III. These observations suggest a possible role in increased level of progesterone in luteal phase on respiratory system.  相似文献   

9.
Lung functions were studied in contemporary healthy Indian female athletes of Ladakhi, Delhi, Vanvasi and Siddi origin training for running events of varying distances. The aim of the study was to compare the lung function in females belonging to these four groups to examine lung function in relation to ethnic and environmental factors. Vital Capacity (VC), Forced Vital Capacity (FVC), Forced Expiratory Volume in Ist second (FEV1), Expiratory Reserve Volume (ERV), and Inspiratory Capacity (IC) were recorded using conventional closed circuit spirometry. Maximum Voluntary Ventilation (MVV) was estimated by collecting expired air during deep and rapid breathing in a 100 liters meterological balloon for a period of 15 seconds and measuring its volume. It was found that Ladakhi females were having significantly higher VC, FVC and FEV1 values than their counterparts. However, there was no significant difference in MVV amongst Delhi, Siddi and Vanvasi young females. The average MVV of Ladakhi females was only significantly higher than Siddi females (P < 0.05).  相似文献   

10.
目的:探讨儿童普通肺炎支原体肺炎(MPP)急性期及恢复期肺通气功能的变化及其检测意义。方法:选取2014年6月至2015年6月在我院住院的5~14岁普通MPP急性期(发病1周内)患儿74例,行常规肺功能检测,随访至恢复期(发病后第3周),66例再次行常规肺功能检测;另选取同期健康儿童60例作为对照组。结果:普通MPP急性期各项肺功能指标(FVC、FEV1、PEF、FEF25、FEF50、FEF75、MMEF)与FEV1/FCV较恢复期均下降(P均<0.01);恢复期FVC、FEV1、PEF基本恢复正常,而FEF25、FEF50、FEF75、MMEF较对照组仍有减低(P均<0.01);急性期与恢复期FEV1/FVC均保持在正常范围。结论:儿童普通MPP急性期存在限制性、阻塞性通气功能障碍及小气道损害,限制性通气功能障碍相对较轻,小气道损害相对较重,而在恢复期限制性及阻塞性肺通气功能障碍明显改善,但仍有小气道损害,故普通MPP小气道损害时间明显较大气道长。肺通气功能检测可以较为客观地反映肺损害的情况,可以判断病情轻重、评估疗效及判断预后。  相似文献   

11.
廉建丽  李继玲  陈俊松 《安徽医药》2019,23(6):1101-1104
目的 探讨小气道功能指标在儿童哮喘病情严重程度评估及临床诊断中的应用价值。方法 选取2013年5月至2016年4月于郑州市第二人民医院56例哮喘急性发作期病儿作为哮喘组,并根据哮喘急性发作严重程度分为轻度(21例)、中度(20例)和重度(15例)三个亚组,同时选取同期、年龄相仿及性别相匹配的30例因其他原因引起喘息咳嗽的慢性炎症病儿和32例入院检查健康儿童分别作为非哮喘组和对照组,收集各组儿童一般资料,采用肺功能测定系统检测各组儿童用力肺活量(FVC)、最大呼气流量(PEF)、第1秒用力呼气容积(FEV1)和FEV1/FVC比值、呼出25%肺活量时呼气流速(FEF25%)、呼出50%肺活量时呼气流速(FEF50%)、呼出75%肺活量时呼气流速(FEF75%)、最大中期呼气流速(MMEF)等指标。结果 与对照组比较,非哮喘组和哮喘组病儿FVC、FEV1、PEF、FEF25%、FEF50%、FEF75%和MMEF等指标均显著降低(P<0.05),且哮喘组病儿上述指标显著低于非哮喘组[(1.42±0.36)L比(1.85±0.47)L、(1.25±0.32)L比(1.42±0.41)L、(2.68±0.64)L比(3.25±0.77)L/s、(2.54±0.65)L/s比(3.74±0.68)L/s、(1.58±0.36)L/s比(2.24±0.71)L/s、(0.61±0.37)L/s比(1.02±0.41)L/s、(1.42±0.49)L/s比(1.89±0.68)L/s)](均P<0.05),而三组病儿FEV1/FVC指标差异无统计学意义(P>0.05)。哮喘急性发作期不同程度病儿用力呼出25%肺活量的呼气流量占预计值百分比(FEF25pred%)、用力呼出50%肺活量的呼气流量占预计值百分比(FEF50pred%)、用力呼出75%肺活量的呼气流量占预计值百分比(FEF75pred%)、最大呼气中期流量占预计值的百分比(MMEFpred%)等指标比较差异有统计学意义(P<0.05),且随着病情程度增加,病儿FEF25pred%、FEF50pred%、FEF75pred%、MMEFpred%等指标呈现明显降低趋势(P<0.05),FEF25%和FEF75%指标在不同严重程度哮喘病儿中异常率比较,差异有统计学意义(P<0.05),FEF50%和MMEF指标比较差异无统计学意义(P>0.05),其中FEF25%主要表现为轻度异常,而FEF75%主要表现为重度异常。结论 小气道功能指标在儿童哮喘病情严重程度评估及临床诊断具有重要意义,随着病情加剧,小气道功能指标明显降低,且异常率显著增加。  相似文献   

12.
Air conditioning may affect human health since it has profound effect on our environment, than just lowering temperature. The present study was planned to assess the effect of air conditioners (AC) on pulmonary functions in young healthy non-smoker males. The study group comprised of ten subjects who were using AC's in their cars for at least 1 hr daily since last 6 months. While ten subjects who did not use AC at all served as controls. The pulmonary functions were assessed using PK Morgan 232 spirometer in a closed room. The peak expiratory flow rate (PEFR) and Forced expiratory flow between 25-75% of vital capacity (FEF25-75) were significantly reduced in subjects using car AC's. Inspiratory flow rates also showed a trend towards decline in AC users but could not reach the level of significance. The lung volumes and capacities were not significantly different in the two groups except for forced expiratory volume in 0.5 sec (FEV 0.5 sec), which also decreased in AC users. The airway resistance and lung compliance did not show significant change. In the presence of normal FEV1, reduced FEF25-75% which is the flow rate over the middle half of vital capacity, is an evidence of mild airflow limitation. The result is suggestive of predisposition of AC users towards respiratory disorders in form of mild airflow restriction.  相似文献   

13.
The study was conducted on 100 pregnant women in third trimester of uncomplicated pregnancy (Test group) and 100 age-matched non-pregnant women (Control group) in the age group of 25 to 35 years. Pulmonary function test parameters FVC, FEV1, PEFR and FEF25-75% recorded using Medspiror. The FEV1/FVC ratio was calculated. All parameters except FEV1/ FVC ratio were found to decline in the Test group as compared to the Control group. The decrease in FEV1 with pregnancy was not of such amplitude as decrease in FVC, and hence FEV1/FVC ratio was seen to increase. This study validates the physiological changes in pulmonary function brought by pregnancy and highlights the need to compile expected and accepted alterations in predicted values of PFT in comparison with the non gravid states for safer outcome of the pregnancy.  相似文献   

14.
We have studied Pulmonary Function Tests (PFTs) namely Vital Capacity (VC). Forced Vital Capacity (FVC), and Forced Expiratory Volume in First Second (FEV1). Forced Expiratory Flow(FEF 25-50%) in 1200 elderly subjects above 60 years of age of which 570 were females and 630 males. Mean age was 69.22 +/- 5.57 years in males and 68.77 +/- 5.44 in females. The mean value of ventilatory parameters were as follows-1) VC 2.99 +/- 0.5 lt in males and 1.89 +/- 0.29 lt in females. 2) FVC 2.69 +/- 0.58 lt. in males and 1.76 +/- 0.21 lt in females. 3) FEV1/FVC% 83.82 +/- 10.62% in males and 83.37 +/- 11.93% in females. 4) FEF 25-75% was 2.81 +/- 1.20 lt/sec in males and 2.13 +/- 1.27 lt/sec. Physical as well as ventilatory parameters were less in females than for males. The correlation of age with VC and FEV1 was highly significant (P < 0.01) but with FVC was not significant (P > 0.05). The correlation of height, weight and body surface area was not significant with any ventilatory parameter (P > 0.05). Multiple regression equations for VC, FVC and FEV1 were formulated for males and females taking height and age as variables. The predicted values correlated excellently with observed values.  相似文献   

15.
The presence of high concentration of metals (Cr, Cd, Co, Ni, Pb, etc.) in the work place environments of various types of industries including electroplating units are well known to influence respiratory system. Pulmonary function tests including forced expiratory capacity (FVC), volumes, mechanics and slow vital capacity (SVC) were studied in 80 males, divided into group I and Group II of 40 each were drawn from electroplating and non-electroplating units, respectively from East Delhi factories. The lung function tests were measured using computerized Spiro-232 of P.K. Morgan, Values of majority of lung function parameters such as FEV1/FVC%, FEF50 FEF75, PIFR, FIF50, MVV and SVC were decreased in electroplaters, perhaps due to the exposure to metals and their lower anthropmetric results as compared with non electoplaters. Where as results of TLC, FRC, RV & RV/ TLC% were higher in electroplaters and this may be attributed to higher values of RV in them as compared with non electroplaters.  相似文献   

16.
目的:观察哮喘患儿吸入丙酸氟替卡松(辅舒酮)和注射斯奇康治疗后对肺功能的影响程度。方法:应用MasterScope儿童肺功能仪对儿童哮喘进行用药前后肺功能指标测定。结果:在受检20例患儿中,治疗前后其肺功能指标除FVC、FEV1外,PEF、FEF25、FEF50、FEF75均有显著性差异(P<0.05)。结论:丙酸氟替卡松和斯奇康联合用于儿童哮喘的治疗及预防,对缓解症状和改善肺功能均能收到良好效果。  相似文献   

17.
This study was done to identify some factors that affect the growth and development of lung function during adolescence and early adulthood. Forced expiratory spirograms and peak expiratory flow rates were obtained in a cohort of normal young men (n = 63) over a period of 4 years, at intervals of approximately 2 years. Two factors that disturbed the normal pattern of lung function development in this group were smoking and respiratory allergy. Among the smokers and the allergics the decline in the forced expiratory volume expressed as a percentage of the forced vital capacity (FEV1%), the forced expiratory flow in the middle half of the forced vital capacity (FEF25-75%) and the FEF25-75% expressed as a ratio of the forced vital capacity (FEF/FVC) was more than double that among the normal subjects. The number of smokers and of allergics increased during the course of the study from 15 to 19 and from 16 to 23 respectively. There was a significant (P less than .01) interaction between smoking and the manifestation of respiratory allergy. Among nonsmokers, the number of allergic subjects increased from 12 to 13, while among smokers it increased from 4 to 10, during the four years.  相似文献   

18.
Inhaled beta-agonists are commonly prescribed for the symptoms of exercise intolerance in heart failure despite a paucity of data regarding their safety and efficacy. This was a prospective, randomized, double-blind, double-dummy, placebo-controlled 14-day cross-over study to determine if chronic inhaled salmeterol therapy 84 microg every 12 hours improved pulmonary function without augmentation of neurohormonal systems or ventricular ectopy in 8 symptomatic heart failure subjects with left ventricular ejection fraction (LVEF) <40% and FEV1 相似文献   

19.
纤维支气管镜及肺功能检查在气管肿瘤中的应用   总被引:1,自引:0,他引:1  
目的探讨无痛性纤维支气管镜及肺功能检查在原发性气管肿瘤中的应用。方法对气管原发性肿瘤30例患者行无痛性纤维支气管镜及肺功能检查并进行回顾性分析。结果30例均行纤维支气管镜检查和肺功能检查。纤维支气管镜检查示瘸体位于气管上段5例,中段16例,下段9例;气管1/3阻塞者17例,气管2/3阻塞者11例,气管几乎完全阻塞者2例;按流速-容量曲线图形对气管肿瘤分型并分为3组:胸外可变型12例为A组,胸内可变型10例为B组,固定性狭窄型8例为c组。B组、c组呼气峰流速(PEF)、1秒量(FEV1)、1秒率(FEV1/FVC)、用力呼气早期流速(FEF25)、平均呼气中期流速(FEF25-75)较A组显著下降(P〈0.05);A组、c组吸气峰流速(PIF)显著低于B组(P〈0.05)。结论纤维支气管镜结合肺功能检查评价气管肿瘤患者通气功能有一定临床价值。  相似文献   

20.
Thirty three normal male and forty two normal female subjects, of average age of 18.5 years, underwent six weeks course in 'Pranayam' and their ventilatory lung functions were studied before and after this practice. They had improved ventilatory functions in the form of lowered respiratory rate (RR), and increases in the forced vital capacity (FVC), forced expiratory volume at the end of 1st second (FEV1%), maximum voluntary ventilation (MVV), peak expiratory flow rate (PEFR-lit/sec), and prolongation of breath holding time.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号