Purpose

To evaluate the performance of F-18 FDG PET/CT in the detection of bone metastasis in non-small cell lung cancer (NSCLC) patients.

Materials and methods

Three hundred and sixty-two consecutive NSCLC patients who underwent F-18 FDG PET/CT scanning were retrospectively analyzed. Each image of PET/CT, combined CT, and PET was performed at 10 separate areas and interpreted blindly and separately. The sensitivity, specificity and accuracy of F-18 FDG PET/CT, combined CT and F-18 FDG PET were calculated and the results were statistically analyzed.

Results

Bone metastasis was confirmed in 82 patients with 331 positive segments based on the image findings and clinical follow-up. On patient-based analysis, the sensitivity of F-18 FDG PET/CT (93.9%) was significantly higher than those of combined CT (74.4%) and F-18 FDG PET (84.1%), respectively (p < 0.05). The overall specificity and accuracy of combined CT, F-18 FDG PET, and F-18 FDG PET/CT were 90.7%, 93.2%, 98.9% and 87.0%, 91.2%, and 97.8%, respectively (compared with PET/CT, p < 0.05). On segment-based analysis, the sensitivity of the three modalities were 79.5%, 94.3%, and 98.8%, respectively (compared with PET/CT, p < 0.05). The overall specificity and accuracy of the three modalities were 87.9%, 89.2%, 98.6% and 84.5%, 91.2%, 98.7%, respectively (compared with PET/CT, p < 0.05).

Conclusion

F-18 FDG PET/CT is superior to F-18 FDG PET or combined CT in detecting bone metastasis of NSCLC patients because of the complementation of CT and PET. It is worth noting that the added value of F-18 FDG PET/CT may beneficially impact the clinical management of NSCLC.  相似文献   

2.

Objective

To explore the value of 18F fluorodeoxy-glucose (FDG) positron emission tomography (PET) in Burkitt's lymphoma.

Methods

All Burkitt's lymphoma patients referred for FDG PET or FDG PET/computed tomography (CT) exams at our institution from June 2003 to June 2006 were included. Selected patients were followed and clinical information was reviewed retrospectively. Results from FDG PET-PET/CT, as blindly reviewed by a consensus of two experienced readers, were compared with the status of the disease as determined by other laboratory, clinical and imaging exams and clinical follow-up. FDG PET-PET/CT results were classified as true positive or negative and false positive or negative. The degree of FDG uptake in the positive lesions was semiquantified as maximum standard uptake value (SUVmax).

Results

Fifty-seven FDG PET-PET/CT exams were done in 15 patients. Seven exams were done for initial staging, 8 during and 14 after the completion of therapy, and 28 for disease surveillance. For nodal disease FDG PET-PET/CT was true positive in 8, true negative in 47 and false positive in 2 exams (sensitivity 100%, specificity 96%). For extranodal disease FDG PET-PET/CT was true positive in 6, true negative in 48 and false positive in 3 exams (sensitivity 100%, specificity 94%). The mean SUVmax for the positive nodal lesions was 15.7 (range 6.9-21.7, median 18.5) and for extranodal lesions was 14.2 (range 6.2-24.3, median 12.4).

Conclusions

FDG PET-PET/CT is sensitive for the detection of viable disease in Burkitt's lymphoma. Affected areas demonstrated high degree of uptake that was reversible upon successful implementation of treatment.  相似文献   

3.

Objective(s)

Only few information exist about the diagnostic accuracy of PET/CT for restaging patients with metastatic recurrence of breast carcinoma. Therefore, our study hypothesis was to perform diagnostic contrast enhanced CT (ce-CT) and FDG-PET in a one-step investigation, to prove sensitivity of each modality and to determine whether diagnostic PET/CT adds information over PET or contrast enhanced CT alone for restaging of patients with suspected recurrence of breast cancer.

Methods

Fifty-two patients with suspected recurrence of breast cancer were included in our study. All of them were free of metastasis after the first line therapy. Indications for restaging were: Elevated tumor markers n = 32, clinical deterioration n = 16 and/or suspicious findings on other imaging studies n = 48. Integrated PET/CT was performed using contrast-enhanced diagnostic CT for attenuation correction.

Results

PET was correct in 44/52 patients (85%), ce-CT in 38/52 patients (73%) and PET/CT in 50/52 patients (96%). Sensitivity and specificity of lesion detection of PET, CT and PET/CT were 84%, 66% and 93%, and 100%, 92%, and 100%, respectively.

Discussion

PET/CT can improve staging and alter therapeutic options in patients suspected to have breast cancer recurrence and distant metastatic disease, primarily by demonstrating local or distant nodal involvement occult at other imaging studies. The added value of FDG-PET/CT over other diagnostic modalities is mainly expressed by the fact that a noninvasive whole-body evaluation is possible in a single examination.  相似文献   

4.

Background and purpose

Ovarian cancer is the commonest tumor in female patients with a propensity for recurrence even after primary chemotherapy in early stage. The accuracy of CA 125, PET alone, PET-CT, CT and MRI in diagnosing the recurrent ovarian carcinoma has never been systematically assessed, and present systematic review was aimed at this issue.

Methods

We searched for articles published from January 1995 to November 2007, inclusion criteria including: articles were reported in English or Chinese; CA 125, PET whether interpreted with or without the use of CT, CT or MRI was used to detect recurrent ovarian carcinoma; Histopathologic analysis and/or close clinical and imaging follow-up for at least 6 months. We extracted data to calculate sensitivity, specificity, SROC curves and AUC and to test for heterogeneity.

Result

In 34 included studies, CA 125 had the highest pooled specificity, 0.93 (95% CI: 0.89-0.95); PET-CT had highest pooled sensitivity, 0.91 (95% CI: 0.88-0.94). The AUC of CA 125, PET alone, PET-CT, CT and MRI were 0.9219, 0.9297, 0.9555, 0.8845 and 0.7955, respectively. Results of pairwise comparison between each modality demonstrated AUC of PET, whether interpreted with or without the use of CT, was higher than that of CT or MR, p < 0.05. The pooled sensitivity, pooled specificity and AUC showed no statistical significance between PET alone and PET-CT. There was heterogeneity among studies and evidence of publication bias.

Conclusion

PET-CT might be a useful supplement to current surveillance techniques, particularly for those patients with an increasing CA 125 level and negative CT or MR imaging. However, regarding to diagnostic accuracy, interpreted CT images may have limited additional value on PET in detecting recurrent ovarian cancer.  相似文献   

5.

Purpose

The purpose of this study was to compare the capability of integrated FDG-PET/CT for assessment of postoperative intra- and extrathoracic recurrence in non-small cell lung cancer (NSCLC) patients with that of standard radiological examinations.

Materials and methods

A total of 121 consecutive pathologically diagnosed NSCLC patients (80 males, 41 females; mean age, 71 years) underwent pathologically and surgically confirmed complete resection, followed by prospective integrated FDG-PET/CT and standard radiological examinations. Final diagnosis of recurrence was based on the results of more than 12 months of follow-up and/or pathological examinations. The probability of recurrence was assessed with either method for each patient by using 5-point visual scoring system, and final diagnosis was made by consensus between two readers. ROC analysis was used to compare the capability of the two methods for assessment of postoperative recurrence on a per-patient basis. The ROC-based positive test was used to determine optimal cut-off value for FDG uptake measurement at a site suspected on the basis of qualitatively assessed PET/CT. Finally, sensitivities, specificities and accuracies of all methods were compared by means of McNemar's test.

Results

Areas under the curve of qualitatively assessed PET/CT and standard radiological examinations showed no significant differences (p > 0.05). At an optimal cut-off value of 2.5, specificity and accuracy of quantitatively and qualitatively assessed PET/CT were significantly higher than those of qualitatively assessed PET/CT and standard radiological examinations (p < 0.05).

Conclusion

Accuracy of assessment of postoperative intra- and extrathoracic recurrence in NSCLC patients by qualitative and/or quantitative FDG-PET/CT is equivalent to or higher than that by standard radiological examinations.  相似文献   

6.

Objective

To evaluate the impact of adding 18F-fluorine-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the evaluation of suspicious breast lesions on magnetic resonance imaging (MRI).

Methods

Sixty patients with suspicious breast lesions on MRI were selected to perform a PET–CT in prone position, dedicated to the evaluation of the breasts. The areas with increased 18F-FDG concentration relative to normal parenchyma were considered positive on PET–CT. Fusion of PET and MRI images (PET–MRI) was performed on a dedicated workstation to better locate corresponding lesions, and its findings were compared with histological results.

Results

76 lesions were evaluated, including 64 mass lesions (84.2%) and 12 non-mass lesions (15.8%). Lesions’ mean diameter on MRI was 29.6 ± 19.2 mm (range 6–94 mm). PET–CT showed increased metabolically activity on 57 lesions (75.0%), with mean maximum SUV of 5.7 ± 5.0 (range 0.8–23.1). On histopathology, there were 17 (22.4%) benign and 59 (79.7%) malignant lesions. Considering all lesions, PET–MRI fusion provided 89.8% sensitivity, 76.5% specificity and 86.8% accuracy. Considering only mass lesions higher than 10 mm, PET–MRI fusion provided 95.8% sensitivity, 83.3% specificity and 93.3% accuracy.

Conclusion

The inclusion of 18F-FDG PET on the evaluation of suspicious breast lesions on MRI helped to differentiate benign from malignant breast lesions, especially for mass lesions with a diameter higher than 10 mm.  相似文献   

7.

Purpose

to investigate the role of FDG-PET and PET/CT in the evaluation of vasculitis.

Materials and methods

a systematic revision of the papers published in PubMed/Medline until December 2009 was done.

Results

FDG-PET and PET/CT have been proven to be valuable in the diagnosis of large-vessel vasculitis, especially giant cells arteritis with sensitivity values ranging 77% to 92%, and specificity values ranging 89% to 100%. In particular, FDG-PET/CT has demonstrated the potential to non-invasively diagnose the onset of the vasculitis earlier than traditional anatomical imaging techniques, thus enabling prompt treatment. False positive results mainly occur in the differential diagnosis between vasculitis and atherosclerotic vessels in elderly patients. Another area where FDG-PET/CT is gaining wider acceptance is in monitoring response to therapy; it can reliably detect the earliest changes of disease improvement post-therapy, and persistent activity is an indicator of non-responders to therapy. A few data have been reported about medium/small vessel vasculitis.

Discussion

FDG-PET and PET/CT have proven utility: (a) in the initial diagnosis of patients suspected of having vasculitis particularly in those who present with non-specific symptoms; (b) in the identification of areas of increased FDG uptake in which a biopsy should be done for obtaining a diagnosis; (c) in evaluating the extent of the disease; (d) in assessing response to treatment.  相似文献   

8.

Background

Computed tomography (CT) and magnetic resonance imaging (MRI) utilization in Ontario increased drastically since the early 1990s. The effect of an increased number of cancer diagnoses, and an increase in indications for scans has not been assessed. This study was conducted to determine trends in utilization of CT and MRI in cancer patients in Ontario over a period of 9 years.

Methods

Using Ontario Health Insurance Plan billing data linked to the Ontario Cancer Registry, rates of CT and MRI were analyzed by region, year, scan type and socioeconomic status.

Results

CT in cancer patients increased 2.3-fold and accounted for approximately 24% of these scans. MRI in cancer patients increased by 4.2-fold and accounted for approximately 10% of these scans. Imaging rates for cancer patients increased more gradually than that of the general population. Substantial variation in the rate of both scans by region of patient residence existed. Even greater variation by the location of the scanner was demonstrated, indicating that many cancer patients traveled outside their region for imaging. There was little evidence of variation in scanning rates by socioeconomic status.

Conclusion

A minority of CT and MRI performed in Ontario are for cancer care. Regional variation in imaging rates suggest that utilization guidelines be developed or knowledge transfer initiatives improve compliance to existing guidelines are needed. A significant number of cancer patients travel outside their region for diagnostic imaging; this should influence decisions about the location of new scanners.  相似文献   

9.

Purpose

To investigate the feasibility and potential added value of dedicated axillary 18F-FDG hybrid PET/MRI, compared to standard imaging modalities (i.e. ultrasound [US], MRI and PET/CT), for axillary nodal staging in clinically node-positive breast cancer.

Methods

Twelve patients with clinically node-positive breast cancer underwent axillary US and dedicated axillary hybrid 18F-FDG PET/MRI. Nine of the 12 patients also underwent whole-body PET/CT. Maximum standardized uptake values (SUVmax) were measured for the primary breast tumor and the most FDG-avid axillary lymph node. A positive axillary lymph node on dedicated axillary hybrid PET/MRI was defined as a moderate to very intense FDG-avid lymph node. The diagnostic performance of dedicated axillary hybrid PET/MRI was calculated by comparing quantitative and its qualitative measurements to results of axillary US, MRI and PET/CT. The number of suspicious axillary lymph nodes was subdivided as follows: N0 (0 nodes), N1 (1–3 nodes), N2 (4–9 nodes) and N3 (≥ 10 nodes).

Results

According to dedicated axillary hybrid PET/MRI findings, seven patients were diagnosed with N1, four with N2 and one with N3. With regard to mean SUVmax, there was no significant difference in the primary tumor (9.0 [±5.0] vs. 8.6 [±5.7], p = 0.678) or the most FDG-avid axillary lymph node (7.8 [±5.3] vs. 7.7 [±4.3], p = 0.767) between dedicated axillary PET/MRI and PET/CT. Compared to standard imaging modalities, dedicated axillary hybrid PET/MRI resulted in changes in nodal status as follows: 40% compared to US, 75% compared to T2-weighted MRI, 40% compared to contrast-enhanced MRI, and 22% compared to PET/CT.

Conclusions

Adding dedicated axillary 18F-FDG hybrid PET/MRI to diagnostic work-up may improve the diagnostic performance of axillary nodal staging in clinically node-positive breast cancer patients.
  相似文献   

10.

Purpose

To determine the role of MRI in the evaluation and management of patients with suspicious nipple discharge and normal mammographic and US evaluation.

Patients and methods

A total of 50 patients with suspicious nipple discharge and normal mammographic and US evaluation prospectively underwent MRI. The first 16 patients underwent routine breast MRI, while MR-ductography with image fusion at the console was added for the last 34 patients.

Results

In 22 of 25 high-risk and malignant lesions, MRI showed enhancement whereas it was normal in three cases. In 25 benign cases (resolution of discharge/benign non-proliferative breast disease), MRI was negative in 22 cases and falsely positive in three cases.

Conclusion

In this clinical setting, MRI shows excellent sensitivity, PPV and NPV. A negative result on MRI would support clinical follow-up as opposed to surgery.  相似文献   

11.

Purpose

Solid organ transplant (SOT) recipients are at high risk of developing infections and malignancies. 18F-FDG PET/CT may enable timely detection of these diseases and help to ensure early intervention. We aimed to describe the clinical utility of FDG PET/CT in consecutive, diagnostic unresolved SOT recipients transplanted from January 2004 to May 2015.

Methods

Recipients with a post-transplant FDG PET/CT performed as part of diagnostic work-up were included. Detailed chart reviews were done to extract relevant clinical information and determine the final diagnosis related to the FDG PET/CT. Based on á priori defined criteria and the final diagnosis, results from each scan were classified as true or false, and diagnostic values determined.

Results

Among the 1,814 recipients in the cohort, 145 had an FDG PET/CT performed; 122 under the indication of diagnostically unresolved symptoms with a suspicion of malignancy or infection. The remaining (N?=?23) had an FDG PET/CT to follow-up on a known disease or to stage a known malignancy. The 122 recipients underwent a total of 133 FDG PET/CT scans performed for a suspected malignancy (66 %) or an infection (34 %). Sensitivity, specificity, and positive and negative predictive values of the FDG PET/CT in diagnosing these conditions were 97, 84, 87, and 96 %, respectively.

Conclusion

FDG PET/CT is an accurate diagnostic tool for the work-up of diagnostic unresolved SOT recipients suspected of malignancy or infection. The high sensitivity and NPV underlines the potential usefulness of PET/CT for excluding malignancy or focal infections in this often complex clinical situation.
  相似文献   

12.

Objective

The purpose of this study was to assess the diagnostic value of PET/CT as a one step examination in patients with colorectal cancer. Therefore we proved whether diagnostic PET/CT adds information over PET or contrast-enhanced CT alone for staging or restaging of patients with colorectal cancer.

Methods

Seventy-three patients (46 males and 27 females; age range: 50-81 years; mean age: 67 years) with known colorectal cancer underwent 18F-FDG-PET/CT for staging or restaging.

Results

Of the 73 patients 26 patients underwent PET/CT for staging and 47 for restaging. 266 metastases could be detected in 60 patients. Contrast-enhanced PET/CT had a lesion-based sensitivity of 100%, contrast-enhanced CT of 91% and PET of 85%. PET/CT identified 2 lesions as false positive. PET/CT could also reach a patient-based sensitivity of 100%, which was superior to contrast-enhanced CT and PET.

Conclusion

Our study clearly demonstrated the added value of contrast-enhanced PET/CT in staging and restaging patients with colorectal cancer over CT and PET alone.  相似文献   

13.

Objective

The evaluation of breast implants for rupture is currently the domain of ultrasound and MRI, while mammography is of very limited diagnostic value. Recently, specific visualisation of silicone has become feasible using dual-energy CT. Our objective was to evaluate whether it is feasible to identify silicone in breast implants by dual-energy CT and to reliably diagnose or rule out ruptures.

Methods

Seven silicone breast implant specimens were examined on dual-source CT at 100- and 140-kV tube potential with a 0.8-mm tin filter (collimation 128 × 0.6 mm, current–time products 165 and 140 mAsref with modulation, rotation time 0.28 s, pitch 0.55). Two patients scheduled for implant removal or replacement were examined with identical parameters.

Results

The silicone of the implant specimens showed a strong dual-energy signal. In one patient, both implants were intact, while a rupture was identified in the other patient. Ultrasound, MRI, surgical findings and histology confirmed the dual-energy CT diagnosis.

Conclusion

Dual-energy CT may serve as an alternative technique for speedy evaluation of silicone breast implants. Specific clinical studies are required to determine the diagnostic accuracy and define indications for this technique.

Key Points

? Dual-energy CT makes it possible to visualise silicone in breast implants. ? Silicone provides a strong photoelectric effect that can be detected. ? Initial experience suggests that implant ruptures can be identified or ruled out.  相似文献   

14.

Objective

The purpose of this study was to assess the potential role for chemical shift magnetic resonance imaging (MRI) in identifying lymphangiomas from other cystic mesenteric and retroperitoneal masses.

Materials and methods

A retrospective search of radiology database identified 24 consecutive patients with mesenteric and retroperitoneal cysts (nine men, 15 women; mean age, 41 years; age range, 19-75 years) who had undergone MR which included in-phase and opposed-phase chemical shift imaging. Signal intensity (SI) decrease between in-phase and opposed-phase MR images of the cyst was evaluated qualitatively by two radiologists. Ultrasound (US), computed tomography (CT), and MRI findings of the morphological appearances of all the cystic lesions that demonstrated significant signal drop on chemical shift MR were also recorded.

Results

Of mesenteric and retroperitoneal cysts, 33% (8/24) revealed qualitative decrease in intensity on opposed-phase MR images relative to that seen on in-phase images. On ultrasound, these cysts demonstrated anechoic simple fluid. Their mean CT attenuation was 13 HU (range: 5-20 HU). Signal loss on fat-suppressed T1-weighted sequences was displayed only by a single cyst. None of the lesions with qualitative SI decrease on opposed-phase MR showed suggestion of lipid on US and CT.

Conclusion

The presence of intra cystic lipid detected by chemical shift MR may not be overt on cross-sectional imaging such as US and CT. Chemical shift MRI provides additional sensitivity and specificity as an imaging test for demonstration of lipid within mesenteric and retroperitoneal cysts enabling a higher diagnostic yield for lymphangioma leading to more appropriate patient management.  相似文献   

15.

Purpose

The clinical value of positron emission tomography (PET) using 18F-fluorodeoxyglucose (FDG) for follow-up or suspected recurrence of renal cell carcinoma (RCC) has not been fully evaluated. The purpose of this study was to assess the diagnostic performance of FDG-PET for postoperative assessment in patients with RCC.

Methods

We reviewed 28 scans in 23 patients who had undergone FDG-PET scans after surgery for RCC. Diagnostic accuracy of visually interpreted PET was evaluated based on final diagnoses obtained histologically or by clinical follow-up at least 6 months. Also, additional information over CT, influence on treatment decisions, and the accuracy of FDG uptake as a predictor of survival were assessed.

Results

Recurrence of renal carcinoma was histologically (n = 15) or clinically (n = 6) confirmed in 21 of 28 cases. Overall, the sensitivity, specificity, and diagnostic accuracy using FDG-PET were 81%, 71%, and 79%, respectively. In papillary RCC, the sensitivity was 100%; however, that was 75% in clear cell RCC in patient-basis. PET correctly detected local recurrence and metastases in all cases in the peritoneum, bone, muscle and adrenal gland. Additional information was obtained from scans in 6 cases (21%), which influenced therapeutic management in 3 cases (11%). Cumulative survival rates over 5 years in the PET-positive vs. the PET-negative group were 46% vs. 83%, respectively (p = 0.17).

Conclusions

FDG-PET would be useful for postoperative surveillance in patients with RCC, although its impact on treatment decisions may be limited. Further investigations are necessary to conclude whether PET has a prognostic value.  相似文献   

16.

Purpose

To compare diagnostic capability of preoperative N-staging of lung cancer between thin-section CT of the mediastinum and FDG PET, and 5 mm slice thickness CT.

Materials and methods

The subjects were 34 patients with lung carcinoma who were examined by both CT and PET, and subsequently underwent surgery between May 2005 and January 2007. CT was carried out with a 16 detector row helical CT scanner. The raw data were reconstructed into 5 mm slice thickness and 1 mm slice thickness (thin-section CT). A total of 251 lymph node stations were retrospectively assessed for the presence of lymph node metastasis with thin-section CT, 5 mm CT and PET. In the interpretations of thin-section CT and 5 mm CT, we employed multi-criteria as follows: nodular calcification and intranodal fat as benign criteria, and short-axis diameter more than 10 mm (size criterion), focal low density other than fat, surrounding fat infiltration and convex margin in hilar lymph nodes, as malignant criteria. On PET, maximum standardized uptake value (SUVmax) of 2.5 or more was used as the criterion of malignancy. Sensitivity and specificity were compared between these examinations using McNemar test.

Results

Sensitivities and specificities of thin-section CT, 5 mm CT and PET were 25%, 25%, 25%, and 97%, 94%, 98%, respectively. The statistical analysis revealed that the specificity of 5 mm CT was significantly lower than those of thin-section CT (p = 0.039) and PET (p = 0.006), while no difference was present between thin-section CT and PET.

Conclusion

Thin-section CT of the mediastinum using multiple criteria was comparable to PET in preoperative N-staging of lung cancer.  相似文献   

17.

Purpose

The purpose of this study was to determine whether [68Ga]DOTATATE PET/MRI with diffusion-weighted imaging (DWI) can replace or complement [18F]FDG PET/CT in patients with radioactive-iodine (RAI)-refractory differentiated thyroid cancer (DTC).

Methods

The study population comprised 12 patients with elevated thyroglobulin and a negative RAI scan after thyroidectomy and RAI remnant ablation who underwent both [18F]FDG PET/CT and [68Ga]DOTATATE PET/MRI within 8 weeks of each other. The presence of recurrent cancer was evaluated on a per-patient, per-organ and per-lesion basis. Histology, and prior and follow-up examinations served as the standard of reference.

Results

Recurrent or metastatic tumour was confirmed in 11 of the 12 patients. [68Ga]DOTATATE PET(/MRI) correctly identified the tumour burden in all 11 patients, whereas in one patient local relapse was missed by [18F]FDG PET/CT. In the lesion-based analysis, overall lesion detection rates were 79/85 (93 %), 69/85 (81 %) and 27/82 (33 %) for [18F]FDG PET/CT, [68Ga]DOTATATE PET/MRI and DWI, respectively. [18F]FDG PET(/CT) was superior to [68Ga]DOTATATE PET(/MRI) in the overall evaluation and in the detection of pulmonary metastases. In the detection of extrapulmonary metastases, [68Ga]DOTATATE PET(/MRI) showed a higher sensitivity than [18F]FDG PET(/CT), at the cost of lower specificity. DWI achieved only poor sensitivity and was significantly inferior to [18F]FDG PET in the lesion-based evaluation in the detection of both extrapulmonary and pulmonary metastases.

Conclusion

[18F]FDG PET/CT was more sensitive than [68Ga]DOTATATE PET/MRI in the evaluation of RAI-refractory DTC, mostly because of its excellent ability to detect lung metastases. In the evaluation of extrapulmonary lesions, [68Ga]DOTATATE PET(/MRI) was more sensitive and [18F]FDG PET(/CT) more specific. Furthermore, DWI did not provide additional information and cannot replace [18F]FDG PET for postoperative monitoring of patients with suspected RAI-refractory DTC.
  相似文献   

18.

Purpose

The aim of the study was to prospectively compare the diagnostic value of whole-body diffusion-weighted imaging (DWI) and FDG PET/CT for breast cancer (BC) staging.

Methods

Twenty BC patients underwent whole-body FDG PET/CT and 1.5-T DWI. Lesions with qualitatively elevated signal intensity on DW images (b?=?800 s/mm2) were rated as suspicious for tumour and mapped to individual lesions and different compartments (overall 552 lesions). The apparent diffusion coefficient (ADC) value was determined for quantitative evaluation. Histopathology, MRI findings, bone scan findings, concordant findings between FDG PET/CT and DWI, CT follow-up scans and plausibility served as the standards of reference defining malignancy.

Results

According to the standards of reference, breasts harboured malignancy in 11, regional lymph nodes in 4, M1 lymph nodes in 3, bone in 7, lung in 2, liver in 3 and other tissues in 3 patients. On a compartment basis, the sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) for the detection of malignancies were 94, 99, 98, 97 and 98% for FDG PET/CT and 91, 72, 76, 50 and 96% for DWI, respectively. Of the lesions seen on DWI only, 348 (82%) turned out to be false-positive compared to 23 (11%) on FDG PET/CT. The average lesion ADC was 820?±?300 with true-positive lesions having 929?±?252 vs 713?±?305 in false-positive lesions (p?<?0.0001).

Conclusion

Based on these initial data DWI seems to be a sensitive but unspecific modality for the detection of locoregional or metastatic BC disease. There was no possibility to quantitatively distinguish lesions using ADC. DWI alone may not be recommended as a whole-body staging alternative to FDG PET(/CT). Further studies are necessary addressing the question of whether full-body MRI including DWI may become an alternative to FDG PET/CT for whole-body breast cancer staging.  相似文献   

19.

Purpose

To compare the performance of fluorine-18 fluorodeoxyglucose positron emission tomography and computed tomography (FDG PET/CT) with conventional imaging methods (CIM), including computed tomography (CT), magnetic resonance imaging (MRI), and mammography (MMG) in cancer of unknown primary (CUP).

Methods

A total of 36 patients with CUP, who referred to our clinic for a FDG PET/CT scan, were enrolled in this study. Thirty of the patients were also examined through either diagnostic CT/MRI and/or MMG. The diagnostic performance of both methods for the primary cancer location was analyzed. The results of FDG PET/CT and CIM were compared based on the standard reference of the histopathology and/or clinical and laboratory follow-up.

Results

The primary cancer locations were detected in 24 patients (66.6%, 24/36) by FDG PET/CT, whereas CIM identified the locations in 16 patients (53.3%, 16/30). Sensitivity, specificity, PPV, NPV, and accuracy rates of the detection of the primary tumor localizations were as follows: 83, 70, 89, 58, and 79% for FDG PET/CT; 70, 62, 84, 42, and 68% for CIM, respectively. There was no statistical significance between modalities regarding any of the categories in 30 patients.

Conclusion

FDG PET/CT detected the primary tumors of the patients with CUP more than CIM did. However, the difference between them was not found to be statistically significant. It may be considered that FDG PET/CT scan can be performed as a first-line tool in the initial diagnosis of the patients with CUP and to add radiodiagnostic imaging in selective cases. We conclude that if the first-line examination of a CUP patient has been already performed by a CIM and the result was negative or inconclusive, FDG PET/CT can be considered to avoid unnecessary imaging procedures.
  相似文献   

20.

Background

Positron emission tomography/computed tomography (PET/CT) with 2-deoxy-2-[18F]fluoro-D-glucose (FDG) has become the standard of care for the initial staging and subsequent treatment response assessment of many different malignancies. Despite this success, PET/CT is often supplemented by MRI to improve assessment of local tumor invasion and to facilitate detection of lesions in organs with high background FDG uptake. Consequently, PET/MRI has the potential to expand the clinical value of PET examinations by increasing reader certainty and reducing the need for subsequent imaging. This study evaluates the ability of FDG-PET/MRI to clarify findings initially deemed indeterminate on clinical FDG-PET/CT studies.

Methods

A total of 190 oncology patients underwent whole-body PET/CT, immediately followed by PET/MRI utilizing the same FDG administration. Each PET/CT was interpreted by our institution's nuclear medicine service as a standard-of-care clinical examination. Review of these PET/CT reports identified 31 patients (16 %) with indeterminate findings. Two readers evaluated all 31 PET/CT studies, followed by the corresponding PET/MRI studies. A consensus was reached for each case, and changes in interpretation directly resulting from PET/MRI review were recorded. Interpretations were then correlated with follow-up imaging, pathology results, and other diagnostic studies.

Results

In 18 of 31 cases with indeterminate findings on PET/CT, PET/MRI resulted in a more definitive interpretation by facilitating the differentiation of infection/inflammation from malignancy (15/18), the accurate localization of FDG-avid lesions (2/18), and the characterization of incidental non-FDG-avid solid organ lesions (1/18). Explanations for improved reader certainty with PET/MRI included the superior soft tissue contrast of MRI and the ability to assess cellular density with diffusion-weighted imaging. The majority (12/18) of such cases had an appropriate standard of reference; in all 12 cases, the definitive PET/MRI interpretation proved correct. These 12 patients underwent six additional diagnostic studies to clarify the initial indeterminate PET/CT findings. In the remaining 13 of 31 cases with indeterminate findings on both PET/CT and PET/MRI, common reasons for uncertainty included the inability to distinguish reactive from malignant lymphadenopathy (4/13) and local recurrence from treatment effect (2/13).

Conclusions

Indeterminate PET/CT findings can result in equivocal reads and additional diagnostic studies. PET/MRI may reduce the rate of indeterminate findings by facilitating better tumor staging, FDG activity localization, and lesion characterization. In our study, PET/MRI resulted in more definitive imaging interpretations with high accuracy. PET/MRI also showed potential in reducing the number of additional diagnostic studies prompted by PET/CT findings. Our results suggest that whole-body PET/MRI provides certain diagnostic advantages over PET/CT, promotes more definitive imaging interpretations, and may improve the overall clinical utility of PET.