1.
BACKGROUND: The purposes of this study were (1) to evaluate the wear pattern of the hydroxyapatite-coated "Dual Radius" Omnifit cup, (2) to investigate whether wear is correlated to any demographic or prosthesis-related factors, and (3) to describe micromotion of both the cup and the stem. PATIENTS AND METHODS: 154 hips were implanted between 1990 and 1996 and followed for an average of 6 years. Wear was measured according to the "Charnley-duo" method and, in 79 hips, with radiostereometry IRSA). RSA was also used to evaluate micromotion. We analyzed the femoral heads using scanning electron microscopy, energy dispersive X-ray spectroscopy and an atomic force microscope. RESULT: 66 cups were revised and had a mean annual wear of 0.32 mm compared to 0.12 mm in hips not revised. Osteolytic processes were observed in 35 hips but at revision osteolysis was present in 51 cases. 43/66 sockets were loose. Micromotion evaluated by RSA, weight, age, side, size of cup, screws, polyethylene thickness or shelf-life of the polyethylene did not correlate to wear, whereas male gender did. INTERPRETATION: It is still unclear why about half of our cases had an abnormal wear rate. Annual wear exceeding 0.2 mm is prognostic of late failure and should be considered a warning sign.  相似文献   

2.
Background?The purposes of this study were (1) to evaluate the wear pattern of the hydroxyapatite-coated “Dual Radius” Omnifit cup, (2) to investigate whether wear is correlated to any demographic or prosthesis-related factors, and (3) to describe micromotion of both the cup and the stem.Patients and methods?154 hips were implanted between 1990 and 1996 and followed for an average of 6 years. Wear was measured according to the “Charnley-duo” method and, in 79 hips, with radiostereometry (RSA). RSA was also used to evaluate micromotion. We analyzed the femoral heads using scanning electron microscopy, energy dispersive X-ray spectroscopy and an atomic force microscope.Result?66 cups were revised and had a mean annual wear of 0.32?mm compared to 0.12?mm in hips not revised. Osteolytic processes were observed in 35 hips but at revision osteolysis was present in 51 cases. 43/66 sockets were loose. Micromotion evaluated by RSA, weight, age, side, size of cup, screws, polyethylene thickness or shelf-life of the polyethylene did not correlate to wear, whereas male gender did.Interpretation?It is still unclear why about half of our cases had an abnormal wear rate. Annual wear exceeding 0.2?mm is prognostic of late failure and should be considered a warning sign.  相似文献   

3.
Background Excellent mid-term results have stimulated the use of hemispherical porous-coated cups in hip replacement. With longer follow-up, there have been problems related to polyethylene wear and liner fixation, and osteolysis has been documented in reports of selected cases. We evaluated the clinical and radiographic results of 50 patients followed for 12 years.

Patients and methods 58 consecutive patients (58 hips), mean age 55 years, were operated with Harris-Galante (HG) I or II cups using line-to-line fit and additional screw fixation. Polyethylene linersγ-sterilized in air and 32-mm ceramic heads were used. 8 patients died within 12 years, leaving 50 patients with a complete 12year follow-up. 23 of the cups were also evaluated with radiostereometry (RSA) for migration, liner stability, and wear.

Results All metal shells were still in situ after 12 years. 4 hips had been revised due to femoral loosening. In these revisions, the liner had been exchanged due to wear and/or instability, resulting in a cup survival rate of 89%. 28 cups displayed osteolytic lesions, mainly in relation to screws. RSA revealed minimum translations, but in many cases there were pronounced liner rotations suggesting unstable liners within the metal shell. The annual proximal wear was 0.09 mm and the three-dimensional wear was 0.16 mm.

Interpretation RSA can predict the long-term performance of cup fixation. Low migration during the initial years after implantation indicates excellent long-term results regarding fixation of the metal shell. The main problem with this design appears to be liner instability and osteolysis, factors that are probably interrelated. Because these phenomena are clinically silent, we recommend regular follow-up of patients with HG cups to avoid sudden loosening and complicated revisions.  相似文献   

4.
Background There have only been a few reports regarding the long-term results of uncemented THAs in patients with osteonecrosis.

Patients and methods We evaluated the long-term results of 65 consecutive uncemented total hip arthroplasties (Harris-Galante type I prostheses) in 54 men (59 hips) and 5 women (6 hips) with osteonecrosis of the femoral head. The mean age was 53 (33-64) years. The mean duration of follow-up was 12.5 (10-16) years.

Results 9 femoral stems and 3 acetabular metal shells were revised. 2 polyethylene liners were changed due to excessive wear. A girdlestone procedure was done in 2 patients (2 hips) due to delayed deep infection. The mean polyethylene wear was 0.14 mm per year. 3 non-revised hips had pelvic osteolysis and 18 had femoral osteolysis. The 15-year survival rates, using failure defined as the removal of any component for any reason, were 85 (95% CI; 79-91)% for the acetabular and 80 (74-86)% for the femoral component and 70 (63-77)% for any of the components.

Intepretation The first generation of the HGP design was frequently associated with pain, unstable fixation, and osteolysis. Excessive wear was frequent. The cup showed better durability than the stem.  相似文献   

5.
Background We developed a total hip system using osseointegration guidelines, a metaphyseal-loading proximal femoral replacement in the retained neck and a dual-geometry titanium shell in the acetabulum.

Patients and methods A randomized controlled clinical trial was undertaken in 52 patients (53 hips), using the cemented Spectron stem and cementless Harris-Galante II cup as control implants (24 patients in experimental group, 29 control patients). Clinical measures of Harris Hip Score (HHS), pain score and radiostereometric analysis (RSA) at regular intervals for up to three years were used to monitor progress.

Results No statistically significant differences were found in HHS and pain score; the stability of the cementless experimental implant was also comparable to that of the cemented controls by RSA. 3 revisions were required for migration in the experimental group and 1 was required for component dislocation in the control group.

Interpretation Our findings indicate the practicality of osseointegration of titanium implants, but suggest that current performance is inadequate for clinical introduction. However, the stable fixation achieved in the retained neck in the majority of patients is indicative of osseointegration. This finding will encourage technical and design improvements for enhancement of clinical osseointegration and should also encourage further study. Periprosthetic osteolysis might be avoided by the establishment and maintenance of direct implant-bone connection: “osseointegration”.  相似文献   

6.
Background Polyethylene wear-induced osteolysis is a major cause of implant loosening in total hip arthroplasty. New crosslinked polyethylenes are presumed to give lower wear rates, but no long-term clinical results are available yet.

Patients and methods We compared basic material characteristics and MTS hip joint simulator wear rates of a crosslinked polyethylene (Duration) to those of conventional polyethylene. In a randomized double-blind 5-year clinical follow-up study, 133 hips (67 conventional, 66 Duration) in 127 patients were followed-up for an average of 5 (3-6) years. Wear rates were measured using a computer-based edge detection method. The radiographic appearances of wear-related phenomena were recorded.

Results The Duration polyethylene showed a significantly lower in-vitro wear rate in the simulator study (mean 22 (SD 2.3) vs. 40 (SD 1.5) mm3/106 cycles). Also, the in-vivo wear was lower for Duration (mean 0.083 (SD 0.056) mm/year) than for conventional polyethylene (mean 0.123 (SD 0.082) mm/year). All radiographic signs of osteolysis were less frequent in the Duration group.

Interpretation Our study has given a substantial body of evidence—from lower wear rates, less frequent signs of osteolysis, and higher survival rates after a mean follow-up of 5 years—that Duration provides better clinical outcomes than conventional polyethylene.  相似文献   

7.
Background There are few reports on the outcome of uncemented HA-coated cups in young patients.

Patients I evaluated the 7-year (5-9) results of HA-coated hip prosthesis (ABG, Stryker) in a consecutive series of 65 primary arthroplasties on 56 patients (mean age 44 years). 2 patients were lost to follow-up and 3 died.

Results The cumulative survival rate with revision for any reason as endpoint at 9 years was 98% (95% CI, 96-100) for the stem, 69% (61-77) for the acetabular metal backing, and 59% (50-67) for the polyethylene liner. 15 of 65 cups were revised on average 6 years after the primary operation and 3 more are planned. Revisions were done in 3 hips because of loosening and migration of the cup, and in 12 hips because of wear and progressive osteolysis around stable components. Only hips with migration had clinical symptoms. Visual inspection of polyethylene liners revealed wear of the articulation in all cases, loosening of the locking mechanism in 10 cases and nonarticular surface deformity in 7 hips. All original stems are in situ although femoral osteolysis was seen in 12 cases and 1 hip was reoperated because of periprosthetic traumatic fracture. Despite the high revision rate, the clinical improvement was good: the average pre- and postoperative Harris Hip Scores at the most recent follow-up were 41 and 90, respectively.

Interpretation While the results on the femoral side were good, the survival rates of the acetabular cups were poor and we stopped using ABG I hip prostheses.  相似文献   

8.
Background Aseptic loosening is the major cause of implant failure. In cemented hip arthroplasty, failure of the acetabular side is mainly due to lysis caused by wear particles. By using an implant with low wear characteristics and by enhancing acetabular fixation using an uncemented implant, we aimed to reduce acetabular lysis and thereby loosening.

Patients and methods This was a retrospective cohort study of 119 hips (101 patients) that had the Uncemented Fitmore cup (Sulzer Orthopedics). In 66 patients, the femoral component was CF-30 (Sulzer) used with cement. In the remaining 35 patients, thrust plate prosthesis (TPP) (Sulzer) was used. Of the 101 patients, 94 (112 hips) were available for study. Mean follow-up of the 94 patients was 7 (5-13) years.

Results The mean preoperative Harris hip score was 38 and the mean postoperative Harris hip score was 89 at the last follow-up. Taking aseptic loosening as the endpoint, the survival rate of the Fitmore cup was 100% at 11 years.

Interpretation The uncemented Fitmore acetabular cup with second generation metal-on-metal articulation showed good results with regard to aseptic loosening in the medium term.  相似文献   

9.
Background Acetabular screw cups seem to give high primary stability. We analyzed the migration and loosening behavior of a first-generation screw cup in a longterm follow-up.

Patients and methods We examined 92 uncemented titanium alloy conical screw cups prospectively. Implant migration was assessed with a digital high-precision method (EBRA) with an accuracy of 1.0 mm.

Results After mean 11 (0.5-18) years, 87 patients were available for examination and 5 patients had died. 32 implants had been revised and 7 cases showed radiographic evidence of loosening. The 10-year survival rate was 71%. Migration of more than 1 mm occurred in 53 hips. Implant survival was strongly associated with an annual migration of greater than 0.2 mm.

Interpretation The long-term behavior of this cup is not satisfactory. In spite of extraordinarily high primary implant stability, secondary osseointegration of this cup often fails. The annual migration rate represents a valid parameter for prediction of implant survival.  相似文献   

10.
Background Uncertainty exists as to whether metal backing (MB) of the tibial component is better than an all-polyethylene component (AP). This is valid for both horizontally and completely cemented components. We evaluated completely cemented MB vs. AP (Part 2).

Patients and methods In a randomized study, 39 patients (40 knees) with knee arthrosis were operated with cemented low-conforming total knee arthroplasty (AGC, Biomet) with a tibial component of uniform thickness (8 mm), cemented both beneath the tibial tray and around the stem. 20 patients had an all-polyethylene (AP) tibial component and 20 patients had an identical but metal-backed (MB) tibial component. We used clinical examination and radiostereometric analysis (RSA) to evaluate the hypothesis that MB improves component fixation. Fixation was evaluated using RSA up to 2 years after surgery. Clinical assessment was performed preoperatively and after 2 years using the Hospital for Special Surgeons (HSS) score.

Results We found no differences in micromotion, and no differences in clinical scores could be detected between the groups at any time point.

Interpretation Our findings indicate that there was equal initial fixation of the AP and MB stemmed monobloc components when they were cemented beneath the tibial plateau and around the stem.

  ▪  相似文献   

11.
Background Laboratory tests and early clinical studies have shown that highly cross-linked polyethylene (PE) markedly improves wear resistance compared to conventional PE. We evaluated this type of PE in two randomized clinical studies using radiostereometric analysis (RSA). The 2- and 3-year follow-up of these studies have already been reported. We found a lower penetration rate for the highly cross-linked PE than for conventional PE. We now report the outcome after 5 years.

Patients and methods 60 patients (61 hips) with a median age of 55 years were randomized to receive either highly cross-linked PE (Durasul) or conventional cemented all-polyethylene sockets of the same design. 55 patients (56 hips) were followed for 5 years. In the second study, 32 patients (64 hips) with a median age of 48 years and with bilateral primary or secondary osteoarthritis of the hip had hybrid total hip arthroplasty with liners made of highly cross-linked PE (Longevity) on one side and conventional PE on the other. 23 patients in this study have passed the 5-year follow-up.

Results Bedding-in and creep for the Durasul all-PE was reached by 2 years, and by 1 year for the Longevity liners. In both control groups with conventional PE, this was reached by 6 months. The steady-state wear rate was close to zero in the two study groups and 0.06 mm/ year for the conventional PE in the two control groups.

Interpretation We found that use of highly crosslinked PE instead of conventional PE reduced the wear by more than 95%, which supports continued use of this type of PE in young, active patients.  相似文献   

12.
Background In RSA, tantalum markers attached to metal-backed acetabular cups are often difficult to detect on stereo radiographs due to the high density of the metal shell. This results in occlusion of the prosthesis markers and may lead to inconclusive migration results. Within the last few years, new software systems have been developed to solve this problem. We compared the precision of 3 RSA systems in migration analysis of the acetabular component.

Material and methods A hemispherical and a nonhemispherical acetabular component were mounted in a phantom. Both acetabular components underwent migration analyses with 3 different RSA systems: conventional RSA using tantalum markers, an RSA system using a hemispherical cup algorithm, and a novel modelbased RSA system.

Results We found narrow confidence intervals, indicating high precision of the conventional marker system and model-based RSA with regard to migration and rotation. The confidence intervals of conventional RSA and model-based RSA were narrower than those of the hemispherical cup algorithm-based system regarding cup migration and rotation.

Interpretation The model-based RSA software combines the precision of the conventional RSA software with the convenience of the hemispherical cup algo-rithm-based system. Based on our findings, we believe that these new tools offer an improvement in the measurement of acetabular component migration.  相似文献   

13.
Background We have developed a bone-conserving commercially pure titanium hip replacement system using osseointegration principles: a metaphyseal loading proximal femoral component affixing into the retained neck and metaphysis only, leaving the femoral canal untouched. The acetabular cup closely fits a dual-geometry cavity, avoiding stress protection at the dome.

Patients and methods After extensive laboratory and clinical pilot trial investigations, the surface-engineered implants were submitted to a prospective randomized controlled clinical trial involving 40 patients (40 hips), in which they were compared to the cemented Spectron femoral component and cementless Trilogy cup as control implant. The following clinical measures were used to monitor progress at regular intervals for the first 2 postoperative years: radiostereometric analysis (RSA), Harris Hip Score, pain score, WOMAC, and SF-36.

Results After 2 years of follow-up, no statistically significant differences were seen between the groups concerning rotation or translation along the cardinal axes. The patients receiving the Gothenburg osseointegrated titanium (GOT) system had significantly higher Harris Hip Score at 6 months, suggesting more rapid recovery. WOMAC, SF-36 and pain analysis were similar for the first 2 postoperative years.

Interpretation Our RSA data suggest that osseointegration was achieved for all patients receiving the GOT hip system. This bone-conserving prosthesis may provide a good alternative, especially for young and active patients.  相似文献   

14.
Background We have previously reported that 6 months of oral treatment with clodronate reduced the migration of the NexGen total knee prosthesis during the first postoperative year, as measured by radiostereometry (RSA). We now report the 4-year results.

Methods This was a double-blind randomized study, using RSA with maximal total point motion (MTPM).

Results With analysis according to the “intention to treat” principle, the only remaining difference between the groups at 4 years was reduced rotation around the transverse axis (a secondary variable) in the clodronate group. However, 3 patients (all clodronate) did not take any tablet after surgery. If they are excluded, there was an almost statistically significant difference between the groups at 4 years regarding MTPM from baseline, with the clodronate group showing 25% less migration. From 1 to 4 years, there was no difference in migration rate by MTPM, but there was a continuous increase in rotation around the transverse axis in the controls, which differed from the clodronate group. There were no cases of aseptic loosening. 2 patients had migration of more than 1.3 mm from baseline to 4 years; neither of them had taken clodronate. The others had migration of less than 0.9 mm.

Interpretation Because migration was clearly reduced by clodronate during the first postoperative year, and there was still a difference at 4 years when analyzed per protocol, it appears likely that this treatment can diminish the risk of loosening. The difference in the number of outliers also points in this direction, and may be more relevant than mean migration values.  相似文献   

15.
Background Reconstruction of the bone stock and fixation of the implant remain challenging problems in revision surgery. In this retrospective study, we wanted to gain information on initial stability and wear after revision with the Burch-Schneider ring.

Patients and methods Between 1994 and 1998, we performed 70 reconstructions of the acetabulum with a Burch-Schneider ring in revision arthroplasty. 63 patients could be followed up clinically and radiographically. 40 cups were suitable for EBRA measurements whereas migration and wear could not be assessed by this method in 23 cases due to lack of comparability of pelvic radiographs. The mean follow-up time was 4.7 years.

Results 2 cups were re-revised and 14 cups had breakage or changes of position of the screws. 30 cups showed detectable migration and 18 cups detectable wear. The mean migration was 2.8 mm and the mean wear rate was 0.12 mm/year. 16 cups had detectable migration after 1 year; 11 of these 16 continued to migrate and 9 of them had screw breakage. Both re-revisions showed early migration. Early migration correlated with later screw breakage and the overall migration correlated with wear. The only risk factor found for early migration was the wear rate.

Interpretation The Burch-Schneider ring is an established and reliable implant for cup revision with good clinical results, but it seems to be difficult to maintain intraoperative stability. The implants with continuous migration may lead to late clinical failure and require further observation. Wear may contribute to migration and resorption of the bone graft. ▪  相似文献   

16.
Background Minor design changes may cause major changes in implant performance. Thus, as part of a stepwise introduction of a new low-profile cup, we performed a randomized trial comparing it to a well-docu-mented standard cup.

Patients and methods 60 patients, stratified according to sex, weight, and age, underwent cemented total hip arthroplasty using a Lubinus SP2 stem with ceramic head and were randomized to either the new low-profile Lubinus Flanged Anti-Luxation cup (FAL) or the Lubinus Standard Eccentric cup (Standard). 7 patients were excluded and 53 (28 FAL) were evaluated at 3, 6, 12, and 36 months postoperatively. Primary outcome variables, cup migration (MTPM), and wear (total 3-dimensional femoral head penetration) were measured with radiostereometry (RSA). Clinical outcome was evaluated with the western Ontario and McMaster osteoarthritis index (Womac) and the visual analog pain score (VAS).

Results We found no difference in migration between the FAL and Standard cups. There was no difference in wear between the two cups and there was no correlation between wear and migration. 3 cups (2 FAL and 1 Standard) showed continuous migration of a magnitude that indicated an increased risk of early loosening. Clinical outcome was excellent, without any difference between the 2 groups.  相似文献   

17.
Background Degree of satisfaction with a knee arthroplasty is said to be correlated to reduced pain and better function. During a validation of the Swedish Knee Arthroplasty Register in 1997, previously operated patients were asked how satified they were with their knee. A subgroup of “satisfied” patients was identified who underwent revision within 2 years of having expressed satisfaction. Our aim was to study the revision diagnosis, to determine whether the problem leading to revision had been discovered as a result of routine follow-up, and also to find out when the symptoms leading to revision had started.

Methods We retrospectively studied the medical records of 181 patients (181 knees), with a median age of 74 (31-88) years. 68% were women and the median time between primary operation and revision was 8 (3-21) years.

Results Aseptic loosening (74/181) was the most common diagnosis. 2 cases were revised as a result of routine follow-up. 44% of the medical records included reports of pain in the replaced knee prior to answering the satisfaction questionnaire.

Interpretation Few patients were admitted to knee revision surgery due to medical findings discovered during routine follow-up. The term “satisfaction” must be interpreted with care, as it seems to have a more complex meaning for the patients than absence of knee pain.

  ▪  相似文献   

18.
Background The outcome of femoral component revision with either cemented or proximally coated stems has been disappointing, but revision with extensively coated stems has been promising. We report long-term outcome of a grit-blasted titanium stem entirely plasma sprayed with hydroxyapatite (HA), in femoral revision surgery.

Patients and methods During 1988 to 1993, we performed 66 femoral revisions in 65 patients (49 women) aged mean 58 (28-86) years. 3 patients died before the 10-year follow-up and 4 did not come for the follow-up examination because they had no hip problems, as confirmed by telephone and by a written reply. 1 of these, however, was previously controlled at 10 years. Thus, 59 patients (60 hips) were followed by clinical and radiographic analysis for 10-16 years after femoral stem revision.

Results 1 stem was re-revised due to mechanical failure, and none were revised because of infection. We noticed a low degree of proximal bone loss and a low incidence of distal bone hypertrophy. These observations indicate no significant net transfer of stress proximally to distally, and a somewhat physiological weight distribution from the stem to the femoral bone. The bone changes confirmed a well-fixed femoral component in asymptomatic patients.

Interpretation Our findings indicate good long-term results with a fully HA-coated stem in femoral revision surgery. ▪  相似文献   

19.
Background Limited data exist on the performance of low-viscosity cement in clinically realistic cadaver models.

Methods Paired stem/cement/femur constructs were generated with low-viscosity and standard-viscosity cements. The constructs were created and tested under simulated in vivo conditions, for which novel techniques were developed during this study. Mantle function was quantified by stem/cortex micromotions over 105cycles of “stair-climbing”. Mantle morphology was determined from transverse sections.

Results Penetration of low-viscosity cement was greater proximally but less distally (p = 0.02). Low-viscosity cement resulted in more stem retroversion (p = 0.04), but there was no difference in subsidence (p = 0.4). Low-viscosity cement mantles had greater fractions of non-apposed interface (p = 0.006). Fraction of non-apposed interface predicted stem retroversion (R2 = 0.64, p = 0.002).

Interpretation Low-viscosity cement resulted in inferior cement mantles. Early micromotion was reduced by better interface apposition. The greater stem retroversion of low-viscosity cement would probably lead to higher revision rates. Early stem migration is due to interface non-apposition. Techniques should be developed to reduce non-apposition of cemented interfaces.  相似文献   

20.
Background Non-steroidal anti-inflammatory drugs (NSAIDs) are known to be potent inhibitors of new bone formation. We investigated whether NSAIDs given at surgery influence the long-term results after total hip arthroplasty (THA).

Patients and methods We performed a 10-year follow-up on 142 of 144 patients who had taken part in a randomized trial on the preventive effects of the NSAID ibuprofen on heterotopic ossification after THA. 96 patients were treated with ibuprofen: 48 for 1 week postoperatively, 48 for 2 weeks postoperatively, and 48 patients were not treated.

Results 13 patients had been revised. All revisions except 1 belonged to groups treated with ibuprofen. The 10-year risk for revision was significantly higher in the ibuprofen-treated patients (p = 0.05). Eleven of the revisions occurred due to fractures of the femur (2) or aseptic loosening (9), reasons that may be attributed to negative effects of ibuprofen. For these patients, the 10-year risk for revision was not statistically significantly different between treated and untreated patients (p = 0.08). In addition to the revised patients, 94 other patients were alive at the 10-year follow-up and 84 underwent radiographic examination. 9 loose prostheses were found radiographically, but these were equally distributed between ibuprofen-treated and untreated hips.

Interpretation The high proportion of revisions in the ibuprofen groups, in combination with clinical and experimental evidence of inhibitory effects on new bone formation of NSAIDs, warrants further investigation of the effects of these drugs on prosthetic fixation.