首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Objective:Blood flow is the rate of blood movement and relevant to numerous processes, though understudied in gliomas. The aim of this review was to pool blood flow metrics obtained from MRI modalities in adult supratentorial gliomas.Methods:MEDLINE, EMBASE and the Cochrane database were queried 01/01/2000–31/12/2019. Studies measuring blood flow in adult Grade II–IV supratentorial gliomas using dynamic susceptibility contrast (DSC) MRI, dynamic contrast enhanced MRI (DCE-MRI) or arterial spin labelling (ASL) were included. Absolute and relative cerebral blood flow (CBF), peritumoral blood flow and tumoral blood flow (TBF) were reported.Results:34 studies were included with 1415 patients and 1460 scans. The mean age was 52.4 ± 7.3 years. Most patients had glioblastoma (n = 880, 64.6%). The most common imaging modality was ASL (n = 765, 52.4%) followed by DSC (n = 538, 36.8%). Most studies were performed pre-operatively (n = 1268, 86.8%). With increasing glioma grade (II vs IV), TBF increased (70.8 vs 145.5 ml/100 g/min, p < 0.001) and CBF decreased (85.3 vs 49.6 ml/100 g/min, p < 0.001). In Grade IV gliomas, following treatment, CBF increased in ipsilateral (24.9 ± 1.2 vs 26.1 ± 0.0 ml/100 g/min, p < 0.001) and contralateral white matter (25.6 ± 0.2 vs 26.0± 0.0 ml/100 g/min, p < 0.001).Conclusion:Our findings demonstrate that increased mass effect from high-grade gliomas impairs blood flow within the surrounding brain that can improve with surgery.Advances in knowledge:This systematic review demonstrates how mass effect from brain tumours impairs blood flow in the surrounding brain parenchyma that can improve with treatment.  相似文献   

2.
Objective:To compare left ventricular (LV) and right ventricular (RV) volume, function, and image quality of a respiratory-triggered two-dimensional (2D)-cine k-adaptive-t-autocalibrating reconstruction for Cartesian sampling (2D kat-ARC) with those of the standard reference, namely, breath-hold 2D balanced steady-state free precession (2D SSFP), in patients with repaired tetralogy of Fallot (TOF).Methods:30 patients (14 males, mean age 32.2 ± 13.9 years) underwent cardiac magnetic resonance, and 2D kat-ARC and 2D SSFP images were acquired on short-axis view. Biventricular end-diastolic volume (EDV) and end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and LV mass (LVM) were analysed.Results:The 2D kat-ARC had significantly shorter scan time (35.2 ± 9.1 s vs 80.4 ± 16.7 s; p < 0.0001). Despite an analysis of image quality showed significant impairment using 2D kat-ARC compared to 2D SSFP cine (p < 0.0001), the two sequences demonstrated no significant difference in terms of biventricular EDV, LVESV, LVSV, LVEF, and LVM. However, the RVESV was overestimated for 2D kat-ARC compared with that for 2D SSFP (73.8 ± 43.2 ml vs 70.3 ± 44.5 ml, p = 0.0002) and the RVSV and RVEF were underestimated (RVSV = 46.2±20.5 ml vs 49.4 ± 20.4 ml, p = 0.0024; RVEF = 40.2±12.7% vs. 43.5±14.0%, p = 0.0002).Conclusion:Respiratory-triggered 2D kat-ARC cine is a reliable technique that could be used in the evaluation of LV volumes and function.Advances in knowledge:2D cine kat-ARC is a reliable technique for the assessment LV volume and function in patients with repaired TOF.  相似文献   

3.
Objective:To evaluate the value of using low energy (keV) images in renal dual-energy spectral CT angiography (CTA) and adaptive statistical iterative reconstruction (ASIR) to reduce contrast medium dose.Methods:40 patients with renal CTA on a Discovery CT750HD were randomly divided into two groups: 20 cases (Group A) with 600 mgI kg−1 and 20 cases (Group B) with 300 mgI kg−1. The scan protocol for both groups was: dual-energy mode with mA selection for noise index of 10 HU, pitch 1.375:1, rotating speed 0.6 s/r. Images were reconstructed at 0.625 mm thickness with 40%ASIR, Group A used the conventional 70keV monochromatic images, and Group B used monochromatic images from 40 to 70 keV at 5 keV interval for analysis. The CT values and standard deviation (SD) values of the renal artery and erector spine in the plain and arterial phases were measured with the erector spine SD value representing image noise. The enhancement degree of the renal artery (ΔCT = CT(arterial) -CT(plain)), signal-to-noise ratio (SNR=CTrenal-artery/SDrenal-artery) and contrast-to-noise ratio (CNR=(CTrenal-artery-CTerector spine)/SDerector-spine) were calculated. The single factor analysis of variance was used to analyze the difference of ΔCT, SNR and CNR among image groups with p < 0.05 being statistically significant. The subjective image scores of the groups were assessed blindly by two experienced physicians using a 5-point system and the score consistency was compared by the κ test.Results:Contrast medium dose in the 300 mgI kg−1 group was reduced by 50% compared with the 600 mgI kg−1 group, while radiation dose was similar between the two groups. The subjective scores were 4.00 ± 0.65, 4.50 ± 0.60 and 3.70 ± 0.80 for images at 70 keV (600 mgI kg−1 group), 40 keV (300 mgI kg−1 group) and 45 keV (300 mgI kg−1 group), respectively with good consistency between the two reviewers (p > 0.05). The 40 keV images in the 300 mgI kg−1 group had similar ΔCT (469.77 ± 86.95 HU vs 398.54 ± 73.68 HU) and CNR (15.52 ± 3.32 vs 18.78 ± 6.71) values as the 70 keV images in the 600 mgI kg−1) group but higher SNR values (30.19 ± 4.41 vs 16.91 ± 11.12, p < 0,05)Conclusion:Contrast dose may be reduced by 50% while maintaining image quality by using lower energy images combined with ASIR in renal dual-energy CTA.Advances in knowledge:Combined with ASIR and energy spectrum, can reduce the amount of contrast dose in renal CTA.  相似文献   

4.
Objective:Single prolonged breath-holds of >5 min can be obtained in cancer patients. Currently, however, the preparation time in each radiotherapy session is a practical limitation for clinical adoption of this new technique. Here, we show by how much our original preparation time can be shortened without unduly compromising breath-hold duration.Methods:44 healthy subjects performed single prolonged breath-holds from 60% O2 and mechanically induced hypocapnia. We tested the effect on breath-hold duration of shortening preparation time (the durations of acclimatization, hyperventilation and hypocapnia) by changing these durations and or ventilator settings.Results:Mean original breath-hold duration was 6.5 ± 0.2 (standard error) min. The total original preparation time (from connecting the facemask to the start of the breath-hold) was 26 ± 1 min. After shortening the hypocapnia duration from 16 to 5 min, mean breath-hold duration was still 6.1 ± 0.2 min (ns vs the original). After abolishing the acclimatization and shortening the hypocapnia to 1 min (a total preparation time now of 9 ± 1 min), a mean breath-hold duration of >5 min was still possible (now significantly shortened to 5.2 ± 0.6 min, p < 0.001). After shorter and more vigorous hyperventilation (lasting 2.7 ± 0.3 min) and shorter hypocapnia (lasting 43 ± 4 s), a mean breath-hold duration of >5 min (5.3 ± 0.2 min, p < 0.05) was still possible. Here, the final total preparation time was 3.5 ± 0.3 min.Conclusions:These improvements may facilitate adoption of the single prolonged breath-hold for a range of thoracic and abdominal radiotherapies especially involving hypofractionation.Advances in knowledge:Multiple short breath-holds improve radiotherapy for thoracic and abdominal cancers. Further improvement may occur by adopting the single prolonged breath-hold of >5 min. One limitation to clinical adoption is its long preparation time. We show here how to reduce the mean preparation time from 26 to 3.5 min without compromising breath-hold duration  相似文献   

5.

Purpose

To compare F-18-fluoro-2-deoxy-D-glucose (F-18 FDG) positron emission tomography/computed tomography (PET/CT) imaging at two different circulation times after injection of F-18 FDG in order to measure atherosclerosis in carotid arteries.

Methods

We assessed 12 patients with recent symptomatic plaques in the carotid arteries. F-18 FDG PET/CT carotid plaque imaging was performed for 20 min at 2 h after F-18 FDG injection in five patients and at 3 h in seven patients. We measured vessel wall uptake using the maximal standardized uptake value (SUV), and the mean and maximal blood target-to-background ratios (TBR) of the symptomatic carotid arteries. Blood pool activity (BPA) was measured as the mean SUV of the superior vena cava (SVC) and jugular vein of these 12 patients, and in 14 age- and gender-matched patients who underwent whole-body F-18 FDG PET/CT examinations 1 h after injection.

Results

F-18 FDG PET/CT revealed visible F-18 FDG uptake in all patients with symptomatic carotid plaques. Maximal SUV did not differ between groups evaluated at 2 h and 3 h (2.62 ± 0.45 vs 3.00 ± 0.85, p = 0.335). However, mean (2.04 ± 0.22 vs 3.54 ± 0.62, p < 0.05) and maximal (1.65 ± 0.15 vs 2.70 ± 0.42, p < 0.05) TBR values that were normalized to BPA in the SVC differ significantly.

Conclusions

Symptomatic carotid plaques are visualized for a relatively short period of imaging time on ≥1-h PET/CT images. Quantitative parameters of atherosclerotic carotid arteries are preserved or even increased over time, whereas those of blood pools are decreased.  相似文献   

6.
Objectives:To compare the efficacy and safety of pre-operative localization of ground glass nodule (GGN) using embolization microcoils and the locating needles designed for pulmonary nodules.Methods:From June 2019 to December 2020, 429 patients who received CT-guided localization of single GGN before video-assisted thoracoscopic surgery (VATS) were enrolled. The diameter and depth of GGNs were 0.84 ± 0.39 cm and 1.66 ± 1.37 cm. Among 429 cases, the first 221 GGNs were marked with microcoils (the microcoil group), and the remaining 208 GGNs were marked with the locating needles designed for pulmonary nodules (the locating needle group). SPSS 17.0 statistical software was used to compare the marking success rate, marking time, marking-related complications between two groups. p values < 0.05 were considered statistically significant.Results:The marking time in the microcoil group was longer than that in the locating needle group (11.1 ± 3.9 vs 8.2 ± 2.0 min, t = −7.87, p = 0.000). The marking success rate in the microcoil group was lower than that in the locating needle group (91.4% vs 98.6%, χ2 = 11.27, p = 0.001). In the microcoil group, marking failures included 16 cases of microcoil dislocation and 3 cases of unsatisfactory microcoil position, while all 3 cases of marking failure in the locating needle group were due to unsatisfactory anchor position. No significant differences in the incidence of total complications (23.1% vs 22.1%), pneumothorax (18.1% vs 19.2%), hemorrhage (9.5% vs 9.1%), and hemoptysis (1.8% vs 1.4%) were observed between the two groups. All the complications were minor and did not need special treatment. Except for one case in the microcoil group, which was converted to thoracotomy, the remaining 428 GGNs were successfully resected by VATS.Conclusions:It is safe and effective to perform pre-operative localization of GGN using either embolization microcoil or the locating needle designed for pulmonary nodules. The locating needle is superior to microcoil for marking GGN in terms of procedure time and the success rate. The complication rate of both methods is similar.Advances in knowledge:The locating needle designed for pulmonary nodules has recently been used to mark pulmonary nodule. Its structure can effectively avoid dislocation after localization, and the marking process is simple and quick. Compared with localization using microcoil, it takes less time and has higher success rate to mark GGNs using the locating needle. The complication rate of both methods is similar.  相似文献   

7.
Objectives:In fluoroscopy-guided interventional practices, new dose reduction systems have proved to be efficient in the reduction of patient doses. However, it is not clear whether this reduction in patient dose is proportionally transferred to operators’ doses. This work investigates the secondary radiation fields produced by two kinds of interventional cardiology units from the same manufacturer with and without dose reduction systems.Methods:Data collected from a large sample of clinical procedures over a 2-year period (more than 5000 procedures and 340,000 radiation events) and the DICOM radiation dose structured reports were analysed.Results:The average cumulative Hp(10) per procedure measured at the C-arm was similar for the standard and the dose reduction systems (452 vs 476 μSv respectively). The events analysis showed that the ratio Hp(10)/KAP at the C-arm was (mean ± SD) 5 ± 2, 10 ± 4, 14 ± 4 and 14 ± 6 μSv·Gy−1·cm−2 for the beams with no added filtration, 0.1, 0.4 and 0.9 mm Cu respectively and suggested that the main cause for the increment of the ratio Hp(10)/KAP vs the “standard system” is the use of higher beam filtration in the “dose reduction” system.Conclusion:Dose reduction systems are beneficial to reduce KAP in patients and their use should be encouraged, but they may not be equally effective to reduce occupational doses. Interventionalists should not overlook their own personal protection when using new technologies with dose reduction systems.Advances in knowledge:Dose reduction technology in interventional systems may increase scatter dose for operators. Personal protection should not be overlooked with dose reduction systems.  相似文献   

8.
Objective:To develop and evaluate a practical automatic treatment planning method for intensity-modulated radiation therapy (IMRT) in cervical cancer cases.Methods:A novel algorithm named as Optimization Objectives Tree Search Algorithm (OOTSA) was proposed to emulate the planning optimization process and achieve a progressively improving IMRT plan, based on the Eclipse Scripting Application Programming Interface (ESAPI). 30 previously treated cervical cancer cases were selected from the clinical database and comparison was made between the OOTSA-generated plans and clinical treated plans and RapidPlan-based (RP) plans.Results:In clinical evaluation, compared with plan scores of the clinical plans and the RP plans, 22 and 26 of the OOTSA plans were considered as clinically improved in terms of plan quality, respectively. The average conformity index (CI) for the PTV in the OOTSA plans was 0.86 ± 0.01 (mean ± 1 standard deviation), better than those in the RP plans (0.83 ± 0.02) and the clinical plans (0.71 ± 0.11). Compared with the clinical plans, the mean doses of femoral head, rectum, spinal cord and right kidney in the OOTSA plans were reduced by 2.34 ± 2.87 Gy, 1.67 ± 2.10 Gy, 4.12 ± 6.44 Gy and 1.15 ± 2.67 Gy. Compared with the RP plans, the mean doses of femoral head, spinal cord, right kidney and small intestine in the OOTSA plans were reduced by 3.31 ± 1.55 Gy, 4.25 ± 3.69 Gy, 1.54 ± 2.23 Gy and 3.33 ± 1.91 Gy, respectively. In the OOTSA plans, the mean dose of bladder was slightly increased, with 2.33 ± 2.55 Gy (versus clinical plans) and 1.37 ± 1.74 Gy (vs RP plans). The average elapsed time of OOTSA and clinical planning were 59.2 ± 3.47 min and 76.53 ± 5.19 min.Conclusion:The plans created by OOTSA have been shown marginally better than the manual plans, especially in preserving OARs. In addition, the time of automatic treatment planning has shown a reduction compared to a manual planning process, and the variation of plan quality was greatly reduced. Although improvement on the algorithm is warranted, this proof-of-concept study has demonstrated that the proposed approach can be a practical solution for automatic planning.Advances in knowledge:The proposed method is novel in the emulation strategy of the physicists’ iterative operation during the planning process. Based on the existing optimizers, this method can be a simple yet effective solution for automated IMRT treatment planning.  相似文献   

9.
Objective:To report our experience on stereotactic body radiotherapy (SBRT) in adrenal metastases from lung cancer.Methods:37 oligometastatic lung cancer patients with 38 adrenal metastases submitted to SBRT were retrospectively analyzed. SBRT was delivered by volumetric modulated arc therapy (VMAT) or helical tomotherapy (HT). Primary study end point was local recurrence-free survival (LR-FS) and secondary end points were distant-progression free survival (d-PFS) and overall survival (OS).Results:Median age was 67 years and primary tumor was non-small-cell lung cancer in 27 (73%) and small-cell lung cancer in 10 (27%) patients. Adrenal metastases were in the left side in 66% cases. Median prescribed dose was 30 Gy in 5 fractions for a median biologically equivalent dose (α/β ratio 10  Gy, BED10) of 48 Gy. Most patients (62%) were submitted to SBRT alone, while the others (38%) received chemo-, immune- or target- therapies. Median follow-up was 10.5 months, median OS 16 months and median d-PFS 3 months. 27 (70%) patients obtained a local control with a median LR-FS of 32 months. LR-FS was significantly related to BED10 with a better LC with BED10 ≥72 Gy, 1- and 2 year LR-FS rates were 54.1±11.6% and 45±12.7% vs 100 and 100% for BED ≤59.5 Gy and BED ≥72 Gy, respectively (p = 0.05). There was no severe toxicity.Conclusion:SBRT was effective and safe in lung cancer adrenal metastases. A dose–response relationship was found between BED10 >72 Gy and better local control. No significant toxicity was registered thanks to the respect of dose constraints and suspension of chemo- and target-therapies.Advances in knowledge:SBRT with a BED10 >72 Gy is an effective treatment for adrenal oligometastatic lung cancer patients.  相似文献   

10.
Objective:Qualitative and quantitative image analysis between Iopamidol-370 and Ioversol-320 in stents´ evaluation by coronary computed tomography angiography (CTA).Methods:Sixty-five patients with low-risk stable angina undergoing stent follow-up with coronary CTA were assigned to Iopamidol I-370 (n = 33) or Ioversol I-320 (n = 32) in this prospective, double-blind, non-inferiority, randomized trial. Stent lumen image quality was graded by 5-point Likert Scale. Lumen mean attenuation was measured at native coronary segments: pre-stent, post-stent, distal segments and at coronary plaques. Lumen attenuation increase (LAI) ratio was calculated for all stents. Heart rate (HR) variation, premature heart beats (PHB), heat sensation (HS), blooming and beam hardening were also assessed.Results:Image quality was similar between groups, with no significant difference (Likert score 4.48 ± 0.75 vs 4.54 ± 0.65, p = 0.5). There were similarities in LAI ratio between I-370 and I-320 (0.39 ± 0.42 vs 0.48 ± 0.44 HU, p = 0.08). Regarding lumen mean attenuation at native coronary segments, a significant difference was observed, with I-320 presenting lower values, including contrast mean attenuation in distal segments. After statistical multivariate analysis, three variables correlated with stent image quality: 1) stent diameter, 2) HR variation and 3) stent lumen LAI ratio.Conclusions:There was no significant difference between Iopamidol-370 mgI ml−1 and Ioversol-320 mgI ml−1 contrasts regarding overall stent lumen image quality, which was mainly influenced by stent diameter, HR and LAI ratio. Advances in knowledge: Coronary CTA allows adequate stents'' visualization and image quality is influenced by stent diameter, HR variation and LAI ratio.Stents'' image quality showed no difference between different concentration contrasts (I-370 vs. I-320); however, higher concentration contrasts may provide an improved overall visualization, especially regarding coronary distal segments.  相似文献   

11.
Objectives:To assess the feasibility of a rapid, focused ferumoxytol-enhanced MR angiography (f-FEMRA) protocol in patients with claustrophobia.Methods:In this retrospective study, 13 patients with claustrophobia expressed reluctance to undergo conventional MR angiography, but agreed to a trial of up to 10 min in the scanner bore and underwent f-FEMRA. Thirteen matched control patients who underwent gadolinium-enhanced MR angiography (GEMRA) were identified for comparison of diagnostic image quality. For f-FEMRA, the time from localizer image acquisition to completion of the angiographic acquisition was measured. Two radiologists independently scored images on both f-FEMRA and GEMRA for arterial and venous image quality, motion artefact and diagnostic confidence using a 5-point scale, five being best. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in the aorta and IVC were measured. The Wilcoxon rank-sum test, one-way ANOVA with Tukey correction and two-tailed t tests were utilized for statistical analyses.Results:All scans were diagnostic and assessed with high confidence (scores ≥ 4). Average scan time for f-FEMRA was 6.27 min (range 3.56 to 10.12 min), with no significant difference between f-FEMRA and GEMRA in diagnostic confidence (4.86 ± 0.24 vs 4.69 ± 0.25, p = 0.13), arterial image quality (4.62 ± 0.57 vs 4.65 ± 0.49, p = 0.78) and motion artefact score (4.58 ± 0.49 vs 4.58 ± 0.28, p > 0.99). f-FEMRA scored significantly better for venous image quality than GEMRA (4.62 ± 0.42 vs 4.19 ± 0.56, p = 0.04). CNR in the IVC was significantly higher for steady-state f-FEMRA than GEMRA regardless of the enhancement phase (p < 0.05).Conclusions:Comprehensive vascular MR imaging of the thorax, abdomen and pelvis can be completed in as little as 5 min within the magnet bore using f-FEMRA, facilitating acceptance by patients with claustrophobia and streamlining workflow.Advances in knowledge:A focused approach to vascular imaging with ferumoxytol can be performed in patients with claustrophobia, limiting time in the magnet bore to 10 min or less, while acquiring fully diagnostic images of the thorax, abdomen and pelvis.  相似文献   

12.
Objectives:To compare radiation dose and image quality of single-energy (SECT) and dual-energy (DECT) head and neck CT examinations performed with second- and third-generation dual-source CT (DSCT) in matched patient cohorts.Methods:200 patients (mean age 55.1 ± 16.9 years) who underwent venous phase head and neck CT with a vendor-preset protocol were retrospectively divided into four equal groups (n = 50) matched by gender and BMI: second (Group A, SECT, 100-kV; Group B, DECT, 80/Sn140-kV), and third-generation DSCT (Group C, SECT, 100-kV; Group D, DECT, 90/Sn150-kV). Assessment of radiation dose was performed for an average scan length of 27 cm. Contrast-to-noise ratio measurements and dose-independent figure-of-merit calculations of the submandibular gland, thyroid, internal jugular vein, and common carotid artery were analyzed quantitatively. Qualitative image parameters were evaluated regarding overall image quality, artifacts and reader confidence using 5-point Likert scales.Results:Effective radiation dose (ED) was not significantly different between SECT and DECT acquisition for each scanner generation (p = 0.10). Significantly lower effective radiation dose (p < 0.01) values were observed for third-generation DSCT groups C (1.1 ± 0.2 mSv) and D (1.0 ± 0.3 mSv) compared to second-generation DSCT groups A (1.8 ± 0.1 mSv) and B (1.6 ± 0.2 mSv). Figure-of-merit/contrast-to-noise ratio analysis revealed superior results for third-generation DECT Group D compared to all other groups. Qualitative image parameters showed non-significant differences between all groups (p > 0.06).Conclusion:Contrast-enhanced head and neck DECT can be performed with second- and third-generation DSCT systems without radiation penalty or impaired image quality compared with SECT, while third-generation DSCT is the most dose efficient acquisition method.Advances in knowledge:Differences in radiation dose between SECT and DECT of the dose-vulnerable head and neck region using DSCT systems have not been evaluated so far. Therefore, this study directly compares radiation dose and image quality of standard SECT and DECT protocols of second- and third-generation DSCT platforms.  相似文献   

13.
Objective:To evaluate multiparametric MRI for differentiating benign and malignant soft tissue tumors.Methods:This retrospective study included 67 patients (mean age, 55 years; 18–82 years) with 35 benign and 32 malignant soft tissue tumors. Intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI)-derived parameters (D, D*, f), apparent diffusion coefficient (ADC), and dynamic contrast-enhanced (DCE)-MRI parameters (Ktrans, Kep, Ve, iAUC) were calculated. Myxoid and non-myxoid soft tissue tumors were divided for subgroup analysis. The parameters were compared between benign and malignant tumors.Results:ADC and D were significantly lower in malignant than benign soft tissue tumors (1170 ± 488 vs 1472 ± 349 µm2/s; 1132 ± 500 vs 1415 ± 374 µm2/s; p < 0.05). Ktrans, Kep, Ve, and iAUC were significantly different between malignant and benign soft tissue tumors (0.209 ± 0.160 vs 0.092 ± 0.067 min−1; 0.737 ± 0.488 vs 0.311 ± 0.230 min−1; 0.32 ± 0.17 vs 0.44 ± 0.28; 0.23 ± 0.14 vs 0.12 ± 0.09, p < 0.05, respectively). ADC (0.752), D (0.742), and Kep (0.817) had high AUCs. Subgroup analysis showed that only Ktrans, and iAUC were significantly different in myxoid tumors, while, ADC, D, Ktrans, Kep, and iAUC were significantly different in non-myxoid tumor for differentiating benign and malignant tumors. D, Kep, and iAUC were the most significant parameters predicting malignant soft tissue tumors.Conclusion:Multiparametric MRI can be useful to differentiate benign and malignant soft tissue tumors using IVIM-DWI and DCE-MRI.Advances in knowledge:1. Pure tissue diffusion (D), transfer constant (Ktrans), rate constant (Kep), and initial area under time–signal intensity curve (iAUC) can be used to differentiate benign malignant soft tissue tumors.2. Ktrans and iAUC enable differentiation of benign and malignant myxoid soft tissue tumors.  相似文献   

14.

Objective:

To investigate the effect of tumour necrosis factor (TNF)-α antagonists on MRI dynamic contrast-enhanced (DCE) and diffusion-weighted imaging (DWI) parameters in Crohn''s disease (CD).

Methods:

42 patients with CD (median age 24 years; 22 females) commencing anti-TNF-α therapy with baseline and follow-up (median 51 weeks) 1.5-T MR enterography (MRE) were retrospectively identified. MRE included DCE (n = 20) and/or multi-b-value DWI (n = 17). Slope of enhancement (SoE), maximum enhancement (ME), area under the time–intensity curve (AUC), Ktrans (transfer constant), ve (fractional volume of the extravascular–extracellular space), apparent diffusion coefficient (ADC) and ADCfast/slow were derived from the most inflamed bowel segments. A physician global assessment of disease activity (remission, mild, moderate and severe) at the time of MRE was assigned, and the cohort was divided into responders and non-responders. Data were compared using Mann–Whitney U test and analysis of variance.

Results:

Follow-up Ktrans, ME, SoE, AUC and ADCME changed significantly in clinical responders but not in non-responders, baseline {[median [interquartile range (IQR)]: 0.42 (0.38), 1.24 (0.52), 0.18 (0.17), 17.68 (4.70) and 1.56 mm2 s−1 (0.39 mm2 s−1) vs follow-up [median (IQR): 0.15 (0.22), 0.50 (0.54), 0.07 (0.1), 14.73 (2.06) and 2.14 mm2 s−1 (0.62 mm2 s−1), for responders, respectively, p = 0.006 to p = 0.037}. SoE was higher and ME and AUC lower for patients in remission than for those with severe activity [mean (standard deviation): 0.55 (0.46), 0.49 (0.28), 14.32 (1.32)] vs [0.32 (0.37), 2.21 (2.43) and 23.05 (13.66), respectively p = 0.017 to 0.033]. ADC was significantly higher for patients in remission [2.34 mm2 s−1 (0.67 mm2 s−1)] than for those with moderate [1.59 mm2 s−1 (0.26 mm2 s−1)] (p = 0.005) and severe disease [1.63 mm2 s−1 (0.21 mm2 s−1)] (p = 0.038).

Conclusion:

DCE and DWI parameters change significantly in responders to TNF-α antagonists and are significantly different according to clinically defined disease activity status.

Advances in knowledge:

DCE and DWI parameters change significantly in responders to TNF-α antagonists in CD, suggesting an effect on bowel wall vascularity.  相似文献   

15.
16.
Objective:Left-ventricular (LV) strain measurements with the Displacement Encoding with Stimulated Echoes (DENSE) MRI sequence provide accurate estimates of cardiotoxicity damage related to chemotherapy for breast cancer. This study investigated an automated and supervised deep convolutional neural network (DCNN) model for LV chamber quantification before strain analysis in DENSE images.Methods:The DeepLabV3 +DCNN with three versions of ResNet-50 backbone was designed to conduct chamber quantification on 42 female breast cancer data sets. The convolutional layers in the three ResNet-50 backbones were varied as non-atrous, atrous and modified, atrous with accuracy improvements like using Laplacian of Gaussian filters. Parameters such as LV end-diastolic diameter (LVEDD) and ejection fraction (LVEF) were quantified, and myocardial strains analyzed with the Radial Point Interpolation Method (RPIM). Myocardial classification was validated with the performance metrics of accuracy, Dice, average perpendicular distance (APD) and others. Repeated measures ANOVA and intraclass correlation (ICC) with Cronbach’s α (C-Alpha) tests were conducted between the three DCNNs and a vendor tool on chamber quantification and myocardial strain analysis.Results:Validation results in the same test-set for myocardial classification were accuracy = 97%, Dice = 0.92, APD = 1.2 mm with the modified ResNet-50, and accuracy = 95%, Dice = 0.90, APD = 1.7 mm with the atrous ResNet-50. The ICC results between the modified ResNet-50, atrous ResNet-50 and vendor-tool were C-Alpha = 0.97 for LVEF (55±7%, 54±7%, 54±7%, p = 0.6), and C-Alpha = 0.87 for LVEDD (4.6 ± 0.3 cm, 4.6 ± 0.3 cm, 4.6 ± 0.4 cm, p = 0.7).Conclusion:Similar performance metrics and equivalent parameters obtained from comparisons between the atrous networks and vendor tool show that segmentation with the modified, atrous DCNN is applicable for automated LV chamber quantification and subsequent strain analysis in cardiotoxicity.Advances in knowledge:A novel deep-learning technique for segmenting DENSE images was developed and validated for LV chamber quantification and strain analysis in cardiotoxicity detection.  相似文献   

17.

Purpose

We evaluated the factors affecting changes in the postoperative glomerular filtration rate (GFR) after unilateral nephrectomy in living kidney donors and patients with renal disease.

Methods

We studied 141 subjects who underwent living donor nephrectomy for renal transplantation (n = 75) or unilateral nephrectomy for renal diseases (n = 66). The GFR of the individual kidney was determined by Tc-99m DTPA scintigraphy before and after nephrectomy. By performing multiple linear regression analysis, we evaluated the factors that are thought to affect changes in GFR, such as age, sex, body mass index (BMI), preoperative GFR, preoperative creatinine level, operated side, presence of diabetes mellitus (DM), presence of hypertension (HTN), and duration of follow-up.

Results

In both the donor nephrectomy and the disease nephrectomy groups, GFR increased significantly after nephrectomy (46.9 ± 8.4 to 58.1 ± 12.5 vs. 43.0 ± 9.6 to 48.6 ± 12.8 ml/min, p < 0.05). In the donor nephrectomy group, age was significantly associated with change in GFR (β = -0.3, p < 0.005). In the disease nephrectomy group, HTN, preoperative creatinine level, and age were significantly associated with change in GFR (β = -6.2, p < 0.005; β = -10.9, p < 0.01; β = -0.2, p < 0.01, respectively). This compensatory change in GFR was not significantly related to sex, duration of follow-up, or operated side in either group.

Conclusions

The compensatory change in the GFR of the remaining kidney declined with increasing age in both living kidney donors and patients with renal disease.  相似文献   

18.

Objective:

To evaluate the capacity of diffusion-weighted imaging (DWI) to determine the histological grade of small-sized hepatocellular carcinomas (HCCs) in liver cirrhosis in comparison with T2 weighted imaging.

Methods:

51 cirrhotic patients with 63 histologically proven HCCs ≤2 cm underwent abdominal MRI, including DWI (b-values 50, 400 and 800 s mm−2) and T2 weighted sequences. HCCs were classified into well-differentiated HCCs (n = 37) and moderately differentiated HCCs (n = 26). Relative contrast ratios (RCRs) between the lesions and the surrounding liver were performed and compared between the two groups for T2 weighted images, each b-value and apparent diffusion coefficients (ADCs). A receiver operating characteristic (ROC) analysis was performed to compare RCRs in T2 and diffusion-weighted images.

Results:

We found significant differences in RCRs between well-differentiated vs moderately differentiated HCCs for b = 50, 400 and 800 s mm−2 and T2 weighted images (1.35 ± 0.36 vs 1.86 ± 0.62; 1.35 ± 0.38 vs 1.82 ± 0.60; 1.27 ± 0.30 vs 1.74 ± 0.53; 1.14 ± 0.18 vs 1.43 ± 0.28, respectively; p < 0.001), whereas no significant differences were observed in ADC and ADC RCR (1.05 ± 0.19 vs 0.99 ± 0.15 and 1.1 ± 0.22 vs 1.09 ± 0.23; p = 0.16 and p = 0.82, respectively). No significant difference was found in the areas under the ROC curve for RCRs of T2 weighted images and every DWI b-value (p = 0.18).

Conclusion:

The RCR measurement performed in DWI 50, 400 and 800 b-values and T2 demonstrated a significant difference between well-differentiated and moderately differentiated small-sized HCCs. Furthermore, no difference was shown by using either ADC or ADC RCR.

Advances in knowledge:

DWI with RCR measurement may be a valuable tool for non-invasively predicting the histological grade of small HCCs.Recent advances in liver imaging techniques and a better understanding of imaging findings have facilitated the detection of small nodules in cirrhotic livers. Nodular lesions ≤2 cm against a background of cirrhosis are diagnostically challenging in daily practice.1 The early and accurate diagnosis of hepatocellular carcinomas (HCCs) is of great importance because the best treatment results are obtained in patients with small and non-invasive HCCs.2,3 If small HCCs are not treated, they can grow aggressively and microscopic vascular invasion can occur before the 2-cm cut-off size for small HCCs.1 Fukuda et al4 reported that moderately and poorly differentiated HCCs ≤2 cm have a greater tendency towards microvascular invasion, meaning that the malignant potential of small HCCs should also be taken into account when selecting a treatment. Therefore, the accurate distinction of well-differentiated HCCs from less well-differentiated HCCs is also considered an important issue in planning of the therapeutic strategy, even if the tumour is small.5,6 Considering that histological confirmation of small suspicious hepatic nodules before treatment is often not possible owing to their location in the liver or the risks of track seeding, the role of a non-invasive pre-operative imaging technique for the discrimination of moderate to poorly differentiated HCCs from well-differentiated HCCs is important. Diffusion-weighted imaging (DWI) allows the characterization of microscopic proton displacement and has profoundly improved oncological imaging. Owing to the recent advances in MRI technology, DWI can be applied to liver imaging with improved image quality.7 Several clinical trials have demonstrated the benefit of DWI in the detection and characterization of focal liver lesions.811 There have been attempts to correlate DWI findings with the histological grading of HCCs using signal intensity (SI) and apparent diffusion coefficient (ADC) values, but no consensus in the results was obtained.1218 To the best of our knowledge, the interplay between DWI and histopathological factors in a cohort of patients with exclusively small HCCs (<2 cm) has not been specifically investigated. The purpose of the present study was to investigate whether or not diffusion-weighted (DW) images and ADC could determine the histological grading of HCCs <2 cm in diameter.  相似文献   

19.

Objective:

To investigate the correlation between iodine concentration of dual-energy CT (DECT) and histopathology of surgically resected primary lung cancers.

Methods:

We reviewed the medical records, post-operative pathological records and pre-operative DECT images of patients who underwent surgical lung resection for primary lung cancer. After injection of iodinated contrast media, arterial and delayed phases were scanned using 140- and 80-kV tube voltages. Three-dimensional iodine concentration (iodine volume) of primary tumours was calculated using lung nodule application software.

Results:

A total of 60 patients (37 males and 23 females; age range, 39–84 years; mean age, 69 years) with 62 lung cancers were analysed. The resected tumours were histopathologically classified into well-differentiated (G1; n = 20), moderately differentiated (G2; n = 29), poorly differentiated (G3; n = 9) and undifferentiated (G4; n = 4) groups by degree of tumour differentiation (DTD). The mean ± standard deviation of iodine volume at the delayed phase was 59.6 ± 18.6 HU in G1 tumours, 46.5 ± 11.3 HU in G2 tumours, 34.3 ± 15.0 HU in G3 tumours and 28.8 ± 6.4 HU in G4 tumours; significant differences were observed between groups (p < 0.001). Univariate logistic regression analysis showed that iodine volumes both at the early and delayed phases were significantly correlated with DTD (p = 0.006 and p = 0.001, respectively), whereas gender, body weight and tumour size were not (p = 0.084, p = 0.062 and p = 0.391, respectively).

Conclusion:

The iodine volume of lung cancers was significantly associated with their DTD. High-grade tumours tended to have lower iodine volumes than low-grade tumours.

Advances in knowledge:

Iodine volume measured by DECT could be a valuable functional imaging method to estimate differentiation of primary lung cancer.  相似文献   

20.
Objective:To investigate the feasibility of using deep learning image reconstruction (DLIR) to significantly reduce radiation dose and improve image quality in contrast-enhanced abdominal CT.Methods:This was a prospective study. 40 patients with hepatic lesions underwent abdominal CT using routine dose (120kV, noise index (NI) setting of 11 with automatic tube current modulation) in the arterial-phase (AP) and portal-phase (PP), and low dose (NI = 24) in the delayed-phase (DP). All images were reconstructed at 1.25 mm thickness using ASIR-V at 50% strength. In addition, images in DP were reconstructed using DLIR in high setting (DLIR-H). The CT value and standard deviation (SD) of hepatic parenchyma, spleen, paraspinal muscle and lesion were measured. The overall image quality includes subjective noise, sharpness, artifacts and diagnostic confidence were assessed by two radiologists blindly using a 5-point scale (1, unacceptable and 5, excellent). Dose between AP and DP was compared, and image quality among different reconstructions were compared using SPSS20.0.Results:Compared to AP, DP significantly reduced radiation dose by 76% (0.76 ± 0.09 mSv vs 3.18 ± 0.48 mSv), DLIR-H DP images had lower image noise (14.08 ± 2.89 HU vs 16.67 ± 3.74 HU, p < 0.001) but similar overall image quality score as the ASIR-V50% AP images (3.88 ± 0.34 vs 4.05 ± 0.44, p > 0.05). For the DP images, DLIR-H significantly reduced image noise in hepatic parenchyma, spleen, muscle and lesion to (14.77 ± 2.61 HU, 14.26 ± 2.67 HU, 14.08 ± 2.89 HU and 16.25 ± 4.42 HU) from (24.95 ± 4.32 HU, 25.42 ± 4.99 HU, 23.99 ± 5.26 HU and 27.01 ± 7.11) with ASIR-V50%, respectively (all p < 0.001) and improved image quality score (3.88 ± 0.34 vs 2.87 ± 0.53; p < 0.05).Conclusion:DLIR-H significantly reduces image noise and generates images with clinically acceptable quality and diagnostic confidence with 76% dose reduction.Advances in knowledge:(1) DLIR-H yielded a significantly lower image noise, higher CNR and higher overall image quality score and diagnostic confidence than the ASIR-V50% under low signal conditions. (2) Our study demonstrated that at 76% lower radiation dose, the DLIR-H DP images had similar overall image quality to the routine-dose ASIR-V50% AP images.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号