首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到17条相似文献,搜索用时 203 毫秒
1.
目的:比较冠脉CT与冠脉造影诊断心肌桥的临床价值。方法:收集2015年7月~2020年7月苏州大学第二附属医院心内科收治的107例疑似冠心病患者临床资料。依次进行冠脉CT和冠脉造影检查,计算壁冠状动脉(MCA)狭窄程度,观察前降支、对角支、钝缘支、后降支和回旋支冠脉分布走行以及与心肌的关系,测量心肌桥长度和厚度。比较两种检查方法图像质量优良率、心肌桥检出率以及心肌桥测量指标。分析两种检查方法显示MCA狭窄程度和诊断心肌桥的一致性。以冠脉造影为金标准,计算敏感度、特异度、准确度、阳性预测值、阴性预测值,评估冠脉CT判断MCA中重度狭窄和诊断心肌桥的价值。结果:两种检查方法图像质量优良率均较好,冠脉CT心肌桥检出率显著高于冠脉造影(25.23% vs 14.02%, P<0.05);冠脉CT测得心肌桥长度大于冠脉造影,MCA狭窄程度低于冠脉造影,差异具有统计学意义(P<0.05);冠脉CT和冠脉造影显示MCA狭窄程度的一致性较好(Kappa=0.832, P<0.05);与冠脉造影比较,冠脉CT判断MCA中重度狭窄的敏感度、特异度、准确度、阳性预测值、阴性预测值分别为90.63%、86.67%、74.36%、95.59%、87.85%;冠脉CT和冠脉造影诊断心肌桥的一致性较好(Kappa=0.815, P<0.05);与冠脉造影比较,冠脉CT诊断心肌桥的敏感度、特异度、准确度、阳性预测值、阴性预测值分别为64.29%、73.33%、69.23%、68.75%、68.97%。结论:冠脉CT与冠脉造影对心肌桥诊断均具有一定价值,而冠脉CT具有无创性、图像质量优良率高,且对心肌桥位置及分布显示佳,并对MCA狭窄具有较高敏感度和特异度,更具临床应用优势。  相似文献   

2.
目的观察320排螺旋CT冠脉成像与冠状动脉造影成像技术在诊断冠心病中的应用价值。方法收集我院2011年06月~2012年09月行320排螺旋CT冠状动脉成像和冠状动脉造影的38例临床疑诊冠心病患者的影像资料,对2种方法评价冠状动脉结果进行对比分析。结果本组38例患者经320排螺旋CT冠脉成像均获得了较好的三维重建,显示率为95.00%;冠脉成像技术敏感性为93.90%;特异性为95.65%;阳性预测值PPV为96.25%;阴值预测值NPV为92.96%。结论320层螺旋CT冠脉成像简便易行、安全可靠,是风险较小的无创性检查,可作为冠心病高危人群普查筛选的首选方法之一。  相似文献   

3.
探讨64层螺旋CT冠状动脉成像在冠状动脉支架置入术前评价及术后随访中的临床应用价值.收集2006年7月~2007年5月在我院因拟行冠状动脉支架置入术而接受64层螺旋CT冠状动脉成像检查的46例患者的影像资料,以及同期内冠状动脉支架置入术后进行随访的21例患者共34个支架的影像资料,评估CT冠状动脉成像在冠状动脉支架置入术前评价及术后随访中诊断价值.结果发现64层螺旋CT对冠状动脉支架置入术前评估狭窄≥50%的敏感度、特异度、准确度分别为92.11%、95.64%和94.97%.64层螺旋CT评价支架通畅23个(67.65%),支架轻度狭窄8例(23.53%),重度狭窄3例(8.83%).因此,利用64层螺旋CT可以准确的评价冠状动脉支架置入术前及术后管腔的情况.  相似文献   

4.
目的:探讨经颅多普勒超声(TCD)在脑梗死患者颅内动脉狭窄中的诊断价值。方法:选取深圳市龙华区中心医院2015年1月至2018年9月收治的脑梗死患者100例为研究对象,所有患者实施了TCD检测和CT血管造影(CTA),以CTA检查结果作为临床诊断的标准,对TCD检测脑梗死患者颅内动脉狭窄的诊断效果进行评估。结果:TCD与CTA诊断具有较高一致性,其整体诊断的敏感度为88.46%,特异度为98.57%,阳性预测值为88.46%,阴性预测值为97.03%,诊断符合率为96.48%;而在不同部位诊断中,TCD对于大脑中动脉(MCA)狭窄的敏感度高于其他部位(P0.05),在不同MCA狭窄程度中,中、重度狭窄诊断符合率高于轻度狭窄(P0.05)。结论:TCD应用于脑梗死患者颅内动脉狭窄诊断中,具有较高的敏感度、特异度,与CTA检查一致性较好,尤其是在中、重度MCA狭窄中,诊断效果更好,可作为临床常规筛查或辅助诊断方法。  相似文献   

5.
目的分析64层螺旋CT在急性阑尾炎的临床诊断价值。方法选取86例急性阑尾炎患者均进行64层螺旋CT平面扫描,观察分析取得的CT诊断结果。计算其诊断敏感度、特异度、准确度、阳性预测值及阴性预测值。结果急性阑尾炎不同位置分布比例中,盆腔位占23.61%,回肠后位为21.32%、回肠前位为20.23%、盲肠后位为17.96%、盲肠下位为16.85%;不同位置病理诊断化脓性阑尾炎表现率为52.31%,单纯性阑尾炎表现率为25.58%,坏疽、穿孔现象表现率为22.11%。其诊断敏感度为91.36%,特异度为92.59%,准确度为94.19%,阳性预测值为93.83%,阴性预测值为80.01%。结论采用64层螺旋CT能够快速诊断和显示急性阑尾炎早期的病理特点,准确率高,可为临床治疗方案提供有效数据,具有影像学应用价值。  相似文献   

6.
目的 探讨256层螺旋CT评估心肌桥及伴发血管粥样硬化病变的诊断价值。方法 回顾性收集接受256层螺旋CT检查并于30 d内行选择性冠脉造影检查的(疑似冠心病患者)101例患者相关资料。统计多层螺旋CT和CAG对心肌桥的检出率及检出心肌桥的位置分布;并测量心肌桥的长度,CT血管成像评估载心肌桥-壁冠状动脉冠脉分支粥样硬化的狭窄程度。结果 256层螺旋CT检出16例患者共18段心肌桥,检出率为15.84%,其中最常见的心肌桥部位是前降支中段心肌桥为16段,出现率为88.89%(16/18)。CAG仅检出4例患者共4段心肌桥,检出率为3.96%。256层螺旋CT测量心肌桥的平均长度为(27.20±16.30)mm,CAG证实的CTA评价的载MB-MCA血管节段狭窄程度≥50%有5段(27.78%),CAG证实的CTA评价的载MB-MCA血管节段近段狭窄程度≥50%有6段(33.33%)。结论 256层螺旋CT对心肌桥的检出率明显高于CAG;更清晰显示心肌桥形态结构,并可观察伴发血管的粥样硬化病变。  相似文献   

7.
目的:探析多排螺旋CT对冠状动脉心肌桥的诊断价值及对壁冠状动脉平均长度、埋藏深度、狭窄程度的评估价值.方法:选取2020年8月至2021年8月期间至我院接受多排螺旋CT冠状动脉造影检查的疑似冠心病患者200例作为研究对象,200例患者均统一实施冠脉造影以及64排256层螺旋CT检查.比较不同检查方式下冠心病及冠状动脉心肌桥的检出率,患者壁冠状动脉的平均长度、平均埋藏深度、平均狭窄程度及具体发病位置,并对比不同检查方式患者不良反应发生情况.结果:冠脉造影结果显示200例疑似冠心病患者检出率为70.50%(141/200),76例心肌桥-壁冠状动脉患者包含122处发病位置,壁冠状动脉平均长度为(5.31±2.12)mm、平均埋藏深度为(2.41±1.15)mm、平均狭窄程度为(43.15±10.58)%.螺旋CT结果显示200例疑似冠心病患者检出率为86.50%(173/200),102例出现心肌桥-壁冠状动脉患者包含215处发病位置,壁冠状动脉平均长度为(6.75±2.28)mm、平均埋藏深度为(3.17±1.45)mm、平均狭窄程度为(48.26±10.35)%;冠脉造影下患者不良反应发生率23.00%(46/200)高于多排螺旋CT10.50%(21/200),差异均具有统计学意义(P<0.05).结论:采用多排螺旋CT可准确诊断冠状动脉心肌桥并明确其具体发病位置,具有较高的临床应用价值.  相似文献   

8.
背景:传统的CT在冠心病介入治疗后随访中难以普及,寻找无创、有效的检查方法对支架内再狭窄的评价就成了影像科医生非常关心的课题。 目的:通过在不控制心率下双源CT冠状动脉成像与选择性冠状动脉造影对支架评估的对比,探讨双源CT冠状动脉成像对冠状动脉支架内再狭窄的诊断价值。 方法:收集53例患者共75枚支架在不控制心率情况下同期行双源CT冠状动脉成像及冠状动脉造影检查的患者影像资料,分析双源CT冠状动脉成像诊断支架内再狭窄的敏感性等各项指标。 结果与结论:①双源CT冠状动脉成像能清楚显示全部支架,96%(72/75)支架图像达到良好以上。②双源CT冠状动脉成像对支架内再狭窄诊断的敏感性、特异性、阳性预测值、阴性预测值及准确性,与冠状动脉造影结果比较差异无显著性意义(P > 0.05)。③双源CT冠状动脉成像分别对心率< 70次/min和≥70次/min的患者支架再狭窄检测的敏感性、特异性、阳性预测值、阴性预测值、准确性比较差异无显著性意义 (P > 0. 05 )。④双源CT冠状动脉成像对直径< 3.0 mm支架再狭窄检测的敏感性、特异性、阳性预测值、阴性预测值、准确性低于≥3.0 mm的支架再狭窄(P < 0. 05 )。结果说明,双源CT冠状动脉成像对诊断冠状动脉支架内再狭窄具有较高的应用价值,且不受心率的影响,可作为大直径支架通畅情况的评估方式及小直径支架的初步筛查方法。  相似文献   

9.
目的研究16层螺旋CT对肌桥的诊断及多时相重建对壁冠状动脉狭窄的评价。方法回顾总结我院自2005年9月~2008年3月期间,通过306例冠状动脉CT成像(冠脉CTA)的检查,检出了14例冠脉肌桥患者,经过原始轴位观察、多方位重组(MPR)、最大密度投影(MIP)对肌桥位置的确定,包埋的厚度、范围进行判定,并且利用多时相重建和4D技术对壁冠状动脉在收缩期和舒张期管腔狭窄程度进行评价。结果14例肌桥患者有10例发生在前降支中段,3例发生在对角支近段,其中8例壁冠状动脉在收缩期和舒张期均无狭窄,3例壁冠状动脉在收缩期有轻度狭窄,3例壁冠状动脉中度狭窄,近段冠脉有软硬斑块。结论16层螺旋CT能够很好的显示肌桥的位置、包埋的厚度和范围,对壁冠状动脉在不同时相管腔狭窄程度能够进行正确判断。  相似文献   

10.
目的评价64层螺旋CT冠脉成像与DSA血管造影在冠心病中的诊断价值。方法选取64例冠心病患者均接受64层螺旋CT冠脉成像与DSA血管造影检查,对比两组诊断结果。结果两种检查方法在冠脉不同级别狭窄程度的检出率、节段狭窄冠脉分支的检出率不具备显著性差异,P0.05。结论 64层螺旋CT冠脉成像与DSA血管造影在冠心病疾病诊断中的结果相近,两种检查方式具有各自的应用价值,其数据可作为临床疾病鉴别和治疗的参考依据。  相似文献   

11.
目的 探讨64排螺旋CT冠脉成像中影响图像质量的各种因素及其影响程度以及评估冠脉狭窄的效果.方法 通过838例临床疑似冠心病患者的6_4排螺旋CT冠脉成像,并以其中218例在1周内进行的常规冠状动脉造影为标准,分析64排螺旋CT冠脉成像在评估冠脉狭窄的灵敏度、准确率、阳性预测值和阴性预测值.结果 心率、心率变化幅度、延迟时间设定、β受体阻滞剂、呼吸频率、屏气合作与否、造影剂注射总量与速度、图像重建时相、冠状动脉钙化、扫描参数、患者年龄性别、机器软硬件性能等是影响64排螺旋CT成像质量的因素.64排螺旋CT冠脉成像评估冠脉狭窄的准确率为95.9%,阳性与阴性预测值分别为92.3%、90.0%.结论 得到了影响64排螺旋CT冠脉成像的各种因素,分析了减少和消除这些因素影响的方法.在评估冠脉狭窄方面,64排螺旋CT冠脉成像基本能满足临床要求. Abstract: Objective To study the various factors that influence image quality of 64-slice spiral CT coronary artery imaging, their impact extent and the assessment effect of coronary artery stonnsis. Methods Through examination of 838 clinical coronary heart disease suspect patients, by 64-slice spiral CT coronary artery imaging, in which, 218 patients were also examined by conventional coronary angiagraphy in a week, we took the conventional coronary angiography as the standard, analyzed the 64-slice spiral CT coronary artery imaging in the assessment of coronary artery stenosis by sensitivity, accuracy, positive predictive value and negative predictive value. Results The factors which affect the image quality of 64-slice spiral CT coronary artery imaging include heart rate, heart rate change range, delay time setting, β-blocker, respiratory rate, breath-holding or not, total amount of contrast medium and the speed of injection, image reconstruction phase, coronary artery calcification, the scan parameters, age and sex of patients, machine  相似文献   

12.
Contrast-enhanced multi-detector row spiral computed tomography (MDCT) was introduced as a promising noninvasive method for vascular imaging. This study examined the accuracy of this technique for detecting significant coronary artery stenoses. Both MDCT(Sensation 16, Siemens, Germany, 12x0.75 mm collimation and 0.42 sec rotation speed, 120 kV, 500 effective mA, and 2.7 mm/rotation table-feed) and invasive coronary angiography (CAG) were performed on 61 patients (mean age 59.2+/-10, 44 men) who were suspected of having coronary artery disease. All patients were treated with atenolol (25-50 mg) prior to imaging and the heart rate was maintained below 65 beats per minutes during image acquisition. The images were reconstructed in the diastole around TI-400 ms with a 0.5 mm increment and a 1.0 mm thickness. All coronary arteries with a diameter of 2.0 mm or more were assessed for the presence of a stenosis (>50% luminal narrowing). Two independent radiologists who were unaware of the results of the invasive CAG evaluated the MDCT data, and the results were compared with those from the invasive CAG (interval 1-27, mean 11 days). An evaluation of the CT coronary angiogram (CTCA) was possible in 58 of the 61 patients (95%). Image acquisition of the major coronary arteries including the left main trunk was available in 229 out of 244 arteries. Invasive CAG showed that 35 out of 58 patients had significant coronary artery stenoses by. patient analysis of those who could be evaluated showed that CT coronary angiography correctly classified 30 out of 35 patients as having at least 1 coronary stenosis (sensitivity 85.7%, specificity 91.3%, positive predictive value 93.8%, negative predictive value 80.8%). By analyzing each coronary artery, CAG found 62 stenotic coronary arteries in the 229 coronary arteries that could be evaluated. MDCT correctly detected 50 out of 62 stenotic coronary arteries and an absence of stenosis was correctly identified in 156 out of 167 normal coronary arteries (sensitivity 80.6%, specificity 93.4%, positive predictive value 81.9%, negative predictive value 92.8%). The non-invasive technique of MDCT for examining the coronary artery appears to be a useful method for detecting coronary artery stenoses with a high accuracy particularly with the proximal portion and large arteries.  相似文献   

13.
64层螺旋CT脑动脉瘤血管成像的应用研究   总被引:1,自引:0,他引:1  
目的:评价64层螺旋CT脑动脉成像在脑动脉瘤诊断中的临床应用价值。方法:57例患者全部进行了脑动脉CTA和DSA检查,将DSA检查结果作为参考标准,评估CTA诊断脑动脉瘤的敏感性、特异性、准确性以及阴性预测值。结果:脑动脉CTA49例共有50个动脉瘤,而DSA检查51例发现52个动脉瘤。CTA诊断动脉瘤的特异性为100%,敏感性96.08%,准确性96.5%,阴性预测值75%。结论:64层螺旋CT脑动脉成像诊断动脉瘤特异性、敏感性和准确性高,可以作为脑动脉瘤筛查和术前评估的首选方法,但仍有假阴性,不能完全取代DSA。  相似文献   

14.
BACKGROUND: Resting electrocardiogram (ECG) shows limited sensitivity and specificity for the detection of coronary artery disease (CAD). Several methods exist to enhance sensitivity and specificity of resting ECG for diagnosis of CAD, but such methods are not better than a specialist's judgement. We compared a new computer-enhanced, resting ECG analysis device, 3DMP, to coronary angiography to evaluate the device's accuracy in detecting hemodynamically relevant CAD. METHODS: A convenience sample of 423 patients without prior coronary revascularization was evaluated with 3DMP before coronary angiography. 3DMP's sensitivity and specificity in detecting hemodynamically relevant coronary stenosis as diagnosed with coronary angiography were calculated as well as odds ratios for the 3DMP severity score and coronary artery disease risk factors. RESULTS: 3DMP identified 179 of 201 patients with hemodynamically relevant stenosis (sensitivity 89.1%, specificity 81.1%). The positive and negative predictive values for identification of coronary stenosis as diagnosed in coronary angiograms were 79% and 90% respectively. CAD risk factors in a logistic regression model had markedly lower predictive power for the presence of coronary stenosis in patients than did 3DMP severity score (odds ratio 3.35 [2.24-5.01] vs. 34.87 [20.00-60.79]). Logistic regression combining severity score with risk factors did not add significantly to the prediction quality (odds ratio 36.73 [20.92-64.51]). CONCLUSIONS: 3DMP's computer-based, mathematically derived analysis of resting two-lead ECG data provides detection of hemodynamically relevant CAD with high sensitivity and specificity that appears to be at least as good as those reported for other resting and/or stress ECG methods currently used in clinical practice.  相似文献   

15.
目的评价16层CT冠状动脉成像(CTCA)的临床价值。方法对58例患者进行回顾性心电门控平扫及增强,后处理用Vessel View软件对所有病例扫描图像做多平面重建(MPR),最大密度投影(MIP),容积成像(VRT),其中35例可疑冠心病患者行冠状动脉造影(SCA)比较。以管腔直径减少≥50%作为判定狭窄的标准,对各冠状动脉主要分支进行节段分析。结果85.1%冠状动脉节段图像可以用做评价,可较准确的显示冠状动脉病变。与SCA对照,敏感度和特异度分别为86.5%(32/37)和95.1%(214/225)。结论16层CT冠状动脉成像可显示较长节段的冠状动脉,较为准确地认定冠状动脉病变,具有较高的临床应用价值。  相似文献   

16.
目的 探讨静息心电图、胸痛症状与256层螺旋CT冠脉成像筛查冠心病的诊断价值。方法 收集入院后接受静息心电图、256层螺旋CTA检查共计68例非急症胸痛疑似冠心病患者的相关资料,所有患者30 d内均进行CAG检查。以CAG诊断为标准,采用ROC曲线分析静息心电图、胸痛症状与冠脉CTA筛查冠心病的诊断价值。结果 256层螺旋CTA诊断冠心病的ROC曲线下面积为0.73(P<0.05),其诊断敏感性为96.55%,特异性为50.00%,诊断价值大于静息心电图(AUC=0.50,P>0.05)和胸痛症状(AUC=0.51,P>0.05)。结论 256层螺旋CTA筛查冠心病有较高的诊断价值;静息心电图、胸痛症状对冠心病的筛查存在明显的局限性。  相似文献   

17.
背景:对肾移植后并发移植肾动脉狭窄患者的诊断及随访是否可采用一种无创伤、特异性高、安全的检查方法。 目的:评估多层螺旋CT图像后处理技术对移植肾动脉狭窄的诊断价值。 方法:对11例临床怀疑为移植肾动脉狭窄的患者进行移植肾动脉期的增强扫描,扫描后所得到的数据经容积重建、最大密度投影、曲面重建、多平面重建处理成像。 结果与结论:11例患者均诊断为移植肾动脉狭窄,10例多层螺旋CT图像后处理技术显示移植肾动脉狭窄程度54%~75%,1例移植肾动脉狭窄程度< 50%。吻合口狭窄10例,其中合并移植肾动脉主干狭窄2例;移植肾动脉分支狭窄1例。经数字减影血管造影检查9例,狭窄程度75%~95%,8例置入支架,1例球囊扩张;1例给予药物治疗随访,于2年后出现肾功能进一步恶化及难治性高血压,置入支架。1例无临床症状,经多层螺旋CT移植肾动脉狭窄程度< 50%,随访4年肾功能、血压正常。支架置入治疗的患者中1例行球囊扩张者2年后彩色多普勒提示移植肾吻合口狭窄,行多层螺旋CT检查移植肾动脉狭窄程度< 50%,随访4年3个月,肾功能、血压正常。提示多层螺旋CT后成像技术可作为移植肾动脉狭窄的诊断依据,对区分临床疑似病例,制定支架置入治疗方案,以及术后随访观察有一定的临床参考价值。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号