首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

Mesh fixation is a critical step in TAPP laparoscopic hernia repair because tackers used for this purpose are associated with possible neuralgia.

Methods

For the present study, 70 patients referred with unilateral inguinal or femoral hernia were divided in two groups for hernia repair. In first group mesh was fixed with titanium tacker. In the second group mesh was fixed with a single suture of Vicryl.

Results

Patients in the Vicryl group experienced less postoperative pain and analgesic consumption. Six month follow-up demonstrated no hernia recurrence either.

Conclusions

According to results, use of Vicryl suture instead of a titanium tacker is beneficial owing to reduced pain, less analgesic consumption, and lower cost.  相似文献   

2.

Introduction:

Composite mesh prostheses incorporate the properties of multiple materials for ventral hernia repair. This study evaluated a polypropylene/ePTFE composite mesh with a novel internal polydioxanone (PDO) absorbable ring.

Methods:

Composite mesh was placed intraperitoneally in 16 pigs through an open laparotomy and explanted at 2, 4, 8, and 12 weeks. Intraabdominal adhesions were measured laparoscopically. Host tissue in-growth was assessed histologically and tensiometrically. Degradation of the internal PDO ring component was also measured tensiometrically. Appropriate statistical tests were used, and P≤.05 indicated significance.

Results:

No adhesions were formed in 50% of the grafts explanted at 8 weeks and 25% of grafts explanted at 12 weeks. There were significantly more vascular structures at 8 weeks, 73.5±28, compared with 2 weeks, 6.75±2 (P≤.01). The T-peel force at the mesh-host tissue interface was not significantly different among time points. The absorbable PDO ring underwent complete degradation by 12 weeks.

Conclusions:

This composite mesh was associated with minimal intraabdominal adhesions, progressive in-growth of host tissues, and complete degradation of a novel internal PDO ring that aided mesh positioning. This composite hernia mesh showed a favorable performance in a porcine model of open ventral hernia repair.  相似文献   

3.

Introduction

Liver trauma is a critical condition that requires swift multidisciplinary approach. In complex hepatic injuries perihepatic packing is an established life-saving procedure. The aim of this study is to evaluate and highlight the value of absorbable mesh wrapping of the injured liver, combined with ipsilateral ligation of portal vein branch.

Case presentation

An 82-year-old patient underwent an open cholocystectomy, for gallbladder empyema. The second postoperative day he was re-operated on due to active hemorrhage. The bleeding was controlled by suturing the bed of the gallbladder fossa. During this maneuver a portal vein branch was torn resulting in a rapidly expanding subcapsular liver hematoma which led to the formation of two deep lacerations on the liver parenchyma. This life-threatening condition was treated by wrapping an absorbable mesh around the right liver lobe and subsequently ligating the right portal vein branch extrahepaticaly.

Conclusion

Mesh wrapping of the fragmented liver with absorbable mesh constitutes a safe and effective method, in treating grade IV and V liver injuries, especially when combined with ipsilateral ligation of the bleeding vessel.  相似文献   

4.

Background:

Repairing large hiatal hernias using mesh has been shown to reduce recurrence. Drawbacks to mesh include added time to place and secure the prosthesis as well as complications such as esophageal erosion. We used a laparoscopic technique for repair of hiatal hernias (HH) >5cm, incorporating primary crural repair with onlay fixation of a synthetic polyglycolicacid:trimethylene carbonate (PGA:TMC) absorbable tissue reinforcement. The purpose of this report is to present short-term follow-up data.

Methods:

Patients with hiatal hernia types I-III and defects >5cm were included. Primary closure of the hernia defect was performed using interrupted nonpledgeted sutures, followed by PGA:TMC mesh onlay fixed with absorbable tacks. A fundoplication was then performed. Evaluation of patients was carried out at routine follow-up visits. Outcomes measured were symptoms of gastroesophageal reflux disease (GERD), or other symptoms suspicious for recurrence. Patients exhibiting these complaints underwent further evaluation including radiographic imaging and endoscopy.

Results:

Follow-up data were analyzed on 11 patients. Two patients were male; 9 were female. The mean age was 60 years. The mean length of follow-up was 13 months. There were no complications related to the mesh. One patient suffered from respiratory failure, one from gas bloat syndrome, and another had a superficial port-site infection. One patient developed a recurrent hiatal hernia.

Conclusions:

In this small series, laparoscopic repair of hiatal hernias >5cm with onlay fixation of PGA:TMC tissue reinforcement has short-term outcomes with a reasonably low recurrence rate. However, due to the preliminary and nonrandomized nature of the data, no strong comparison can be made with other types of mesh repairs. Additional data collection is warranted.  相似文献   

5.

Introduction:

Spigelian hernia is an uncommon ventral hernia characterized by a defect in the linea semilunaris. Repair of spigelian hernia has traditionally been accomplished via an open transverse incision and primary repair. The purpose of this article is to present 2 case reports of incarcerated spigelian hernia that were successfully repaired laparoscopically using Gortex mesh and to present a review of the literature regarding laparoscopic repair of spigelian hernias.

Methods:

Retrospective chart review and Medline literature search.

Results:

Two patients underwent laparoscopic mesh repair of incarcerated spigelian hernias. Both were started on a regular diet on postoperative day 1 and discharged on postoperative days 2 and 3. One patient developed a seroma that resolved without intervention. There was complete resolution of preoperative symptoms at the 12-month follow-up.

Conclusion:

Minimally invasive repair of spigelian hernias is an alternative to the traditional open surgical technique. Further studies are needed to directly compare the open and the laparoscopic repair.  相似文献   

6.

Background and Objectives:

Morgagni hernias are unusual congenital diaphragmatic hernias that are generally asymptomatic and discovered incidentally. Surgical treatment is indicated once the diagnosis is made. These hernias have traditionally been repaired by the open abdominal or thoracic approaches. We report a case of Morgagni hernia repaired successfully via the laparoscopic approach.

Methods and Results:

The patient was noted to have a large anteromedial diaphragmatic hernia by chest radiograph and CT imaging. He underwent laparoscopy, during which the hernia was reduced and the defect repaired with mesh placement. We used intracorporeal suture placement to anchor the mesh. The patient recovered uneventfully after a short hospitalization.

Conclusions:

The laparoscopic approach for repair of Morgagni hernias offers diagnostic advantages as well as the potential for reduced morbidity when compared to laparotomy. We report intracorporeal knot-tying for fixation of the mesh to be a secure and satisfactory means to achieve the laparoscopic repair.  相似文献   

7.

Background and Objectives:

To investigate the prevalence, diagnosis, clinical significance, and treatment strategies for bulging in the area of laparoscopic repair of ventral hernia that is caused by mesh protrusion through the hernia opening, but with intact peripheral fixation of the mesh and actually a still sufficient repair.

Methods:

Medical records of all 765 patients who underwent laparoscopic ventral hernia repair were reviewed, and all patients with a swelling in the repaired area were identified and analyzed.

Results:

Twenty-nine patients were identified. They all underwent a computed tomography assessment. Seventeen patients (2.2% of the total group) had a hernia recurrence; in an additional 12 patients (1.6%), radiologic examinations indicated only bulging of the mesh but no recurrence. Bulging was associated with pain in 4 patients who underwent relaparoscopy and got a new, larger mesh tightly stretched over the entire previous repair. Eight asymptomatic patients decided on “watchful waiting.” All patients remained symptom free during a median follow-up of 22 months.

Conclusion:

Symptomatic bulging, though not a recurrence, requires a new repair and must be considered as an important negative outcome of laparoscopic ventral hernia repair. In asymptomatic patients, “watchful waiting” seems justified.  相似文献   

8.

Background and Objectives:

The purpose of this study was to analyze the surgical technique, postoperative complications, and possible recurrence after laparoscopic ventral hernia repair (LVHR) in comparison with open ventral hernia repair (OVHR), based on the international literature.

Database:

A Medline search of the current English literature was performed using the terms laparoscopic ventral hernia repair and incisional hernia repair.

Conclusions:

LVHR is a safe alternative to the open method, with the main advantages being minimal postoperative pain, shorter recovery, and decreased wound and mesh infections. Incidental enterotomy can be avoided by using a meticulous technique and sharp dissection to avoid thermal injury.  相似文献   

9.

Background and Objective:

To determine whether the NiTiNol frame of a novel hernia repair device utilizing polypropylene mesh for inguinal hernioplasty remains stable and intransient without fixation after a minimum of 6 months.

Methods:

Twenty patients had 27 inguinal hernias repaired using a novel hernia repair device that has a NiTiNol frame without any fixation. Initial single-view, postoperative X-rays were compared with a second X-ray obtained at least 6 months later. The NiTiNol frame, which can be easily visualized on a plain X-ray, was measured in 2 dimensions, as were anatomic landmarks. The measurements obtained and the appearances of the 2 X-rays were compared to determine the percentage of change in device size and device stability with regard to device location and shape.

Results:

There were minimal changes noted between the 2 sets of measurements obtained with an overall trend towards a slight increase in the size of the hernia repair device. The devices demonstrated intransience of position and stability of shape.

Conclusions:

The NiTiNol frame of a novel hernia repair device utilizing polypropylene mesh exhibits radiographic evidence of size and shape stability and intransience of position without fixation when used in inguinal hernioplasty after a minimum follow-up of 6 months.  相似文献   

10.
11.

Background and Objectives:

Mesh fixation in laparoscopic umbilical hernia repair is poorly studied. We compared postoperative outcomes of laparoscopic umbilical hernia repair in suture versus tack mesh fixation.

Methods:

Patients who underwent laparoscopic umbilical hernia repair were separated by method of mesh fixation: sutures versus primarily tacks. Medical history and follow-up data were collected through medical records. The primary outcome of this study was the recurrence rates of hernias. Postoperative major and minor complications, such as surgical site infection, small-bowel obstruction, and seroma formation, were regarded as secondary outcomes. Additionally, a telephone interview was conducted to assess postoperative pain, recovery time, and overall patient satisfaction.

Results:

Eighty-six patients were identified: 33 in the suture group and 53 in the tacks group. The number of emergent cases was increased in the tacks group (6 vs 0; P = .022). Mean follow-up time was 2.7 years for both groups. Documented postoperative follow-up was obtained in 29 (90%) suture group and 31 (58%) tacks group patients. Hernia recurrence occurred in 3 and 2 patients in the sutures and tacks groups, respectively (P was not significant). No differences were found in secondary outcomes, including subjective outcomes from telephone interviews, between groups.

Conclusions:

There are no differences in postoperative complication rates in suture versus tack mesh fixation in laparoscopic umbilical hernia repair.  相似文献   

12.

Background & Objectives:

We report on laparoscopic total extraperitoneal repair without fixation of mesh for femoral hernia in 6 patients.

Methods:

During a 3-year period, laparoscopic total extraperitoneal repair of femoral hernia was performed without mesh fixation in 6 patients. The recurrence rate, pain scores, hospital stay, and other morbidity parameters were noted. Pain scores were 1=no pain, 2=mild pain, 3=moderate pain, 4=severe pain, and 5=intolerable pain.

Results:

All 6 patients were females and had unilateral hernias. Mean age was 33.8±18.6 years, and follow-up ranged from 12 months to 36 months. Four patients were operated on while under spinal anesthesia, and 2 patients were operated on while under general anesthesia. Mean operating time was 29.2±10.7 minutes. The mean pain scores 24 hours and the first week after operation were, respectively, 2.33±0.52 and 1.33±0.52. Mean hospital stay was 1.17±0.41 days, and mean days to resumption of normal activities were 8.5±2.1 days. No patient had urinary retention or seroma formation in the postoperative period. At follow-up, no hernia had recurred.

Conclusions:

Laparoscopic femoral hernia repair without fixing the mesh is safe, feasible, and associated with minimal morbidity and recurrence rates.  相似文献   

13.

Background:

The characteristics of the ideal type of mesh are still being debated. Mesh shrinkage and fixation have been associated with complications. Avoiding shrinkage and fixation would improve hernia recurrence rates and complications. To our knowledge, this is the first study of a device with a self-expanding frame for laparoscopic hernia repair.

Methods:

Six Rebound Hernia Repair Devices were placed laparoscopically in pigs. This device is a condensed polypropylene, super-thin, lightweight, macro-porous mesh with a self-expanding Nitinol frame. The devices were assessed for adhesions, shrinkage, and histological examination. Laboratory and radiologic evaluations were also performed.

Results:

The handling properties of the devices facilitated their laparoscopic placement. They were easily identified with simple x-rays. The mesh was firmly integrated within the surrounding tissue. One device was associated with 3 small adhesions. The other 5 HRDs had no adhesions. We noted no shrinkage or folding. All devices preserved their original size and shape.

Conclusions:

At this evaluation stage, we found that the Rebound Hernia Repair Device may serve for laparoscopic hernia repair and has favorable handling properties. It prevents folding and shrinkage of the mesh. It may eliminate the need for fixation, thus preventing chronic pain. The Nitinol frame also allowed radiologic evaluation for gross movement. Further studies will be needed to evaluate its clinical application.  相似文献   

14.

Objective:

Review of international literature reveals eight reported cases of laparoscopic obturator hernia repair. Non-specific signs and symptoms make the diagnosis of an obturator hernia difficult. Laparoscopic intervention provides a minimally invasive method to simultaneously diagnose and repair these hernias.

Methods and Procedures:

A 35 year old woman presented with lower abdominal pain, vaginal bleeding, and dyspareunia. During gynecological diagnostic laparoscopy, a pelvic floor hernia was suspected, and a general surgical evaluation was sought. At a subsequent laparoscopy, the diagnosis of a left direct inguinal and a right obturator hernia was made. Both were repaired laparoscopically with polypropylene mesh.

Results:

At follow-up at one and six weeks postoperatively, the patient''s complaints of pain had completely resolved.

Conclusion:

The diagnosis of obturator hernia is problematic. The usual presenting signs and symptoms are non-specific. Without conclusive historical or physical findings, laparoscopy is an excellent method for diagnosing obturator hernia. This entity, once diagnosed laparoscopically, can be repaired simultaneously via laparoscopic mesh technique.  相似文献   

15.

Background and Objectives:

A Spigelian hernia is a rare type of hernia that occurs through a defect in the anterior abdominal wall adjacent to the linea semilunaris. Estimation of its incidence has been reported as 0.12% of all abdominal wall hernias. Traditionally, the method of repair has been an open approach. Herein, we discuss a series of laparoscopic repairs.

Methods:

Case series and review of the literature.

Cases:

Three patients are presented. All were evaluated and taken to surgery initially for a different disease process, and all were incidentally found to have a spigelian hernia. These patients underwent laparoscopic repair of their hernias; 2 were repaired intraperitoneally and one was repaired totally extraperitoneally. Two patients initially underwent a mesh repair, while the third had an attempted primary repair.

Conclusions:

There is evidence that supports the use of laparoscopy for both diagnosis and repair of spigelian hernias. There are also reports of successful repairs both primarily and with mesh. In our experience with the preceding 3 patients, we found that laparoscopic repair of incidentally discovered spigelian hernias is a viable option, and we also found that implantation of mesh, when possible, resulted in satisfactory results and no recurrence.  相似文献   

16.

INTRODUCTION

Complex hernias continue to present a challenge. Surgical techniques for repair are carefully considered to reduce risk for complications. Laparoscopic repairs improve postoperative infection rates, and placement of biologic mesh decreases mesh infection rates. However, laparoscopic repairs using biologic mesh is generally challenging due to difficulty with maneuverability.

PRESENTATION OF CASE

We present a case of a complex ventral hernia that was laparoscopically repaired using a new FDA cleared laparoscopic biologic graft. The patient had multiple comorbidities, including obesity, hepatitis C, endocarditis secondary to IV drug use, tobacco smoking, bilateral inguinal hernia, and recurrent umbilical hernia. The recurrent hernia was larger, irreducible, and discolored compared to original defect. The patient underwent laparoscopic repair with primary closure and reinforcement with Strattice™ Tissue Matrix Laparoscopic (LifeCell Corporation, Branchburg, NJ). At nine months postoperative, the patient had no evidence of recurrence, infection, or chronic pain, demonstrating early success from the surgical management.

DISCUSSION

Presence of multiple comorbidities and incarcerated recurrent hernia increase risk for complications during and/or after hernia repair. Considering these factors, laparoscopic repair with Strattice Laparoscopic and defect closure was a reasonable technique for repair.

CONCLUSION

Laparoscopic suture repair reinforced with biologic dermal tissue matrix was successfully performed during a complex hernia repair.  相似文献   

17.

Purpose

Laparoscopic hernioplasty has become a popular choice for inguinal hernia repair since its advent in 1990s. Postoperative pain is an undesirable clinical outcome impairing daily activity of 22.5% of patients. The aim of this study is to evaluate postoperative acute and chronic pain via inflammatory markers as an objective assessment following tacks or glue mesh fixation in TEP repair.

Methods

Sixty-six (66) patients with unilateral uncomplicated inguinal hernia were randomized into 34 patients in the tacker and 32 patients in cyanoacrylate glue mesh fixation in TEP repair. The extent of surgical trauma was evaluated by measuring inflammatory markers of C-reactive protein, white blood cell count at 48 h, and ESR at 3 months postoperatively. Postoperative acute and chronic pain was assessed by recording the visual analogue scale scores and surgical complications were recorded over 3 months of the study period.

Results

The median CRP and WBC levels at postoperative 48 h in both groups raised significantly from the baseline values (p < 0.05), however, did not differ significantly between the two study groups at 48 h (p > 0.05). The median ESR level increased significantly at 3 months postoperatively from baseline in the glue mesh fixation group only (p < 0.05), however, did not differ significantly between the two study groups (p > 0.05). There was no significant difference for VAS scores at all timelines between the tacker and glue mesh fixation group (p > 0.05).

Conclusion

Cyanoacrylate glue mesh fixation technique as an alternative method to mechanical fixation in TEP repair is comparable to tacker and can be considered to be safe and feasible.
  相似文献   

18.

Background:

Inguinal hernia repair is the most common procedure in general surgery and 80,000 operations are performed annually in Great Britain, 100,000 in France and 700,000 in the US. Given its high frequency has a major impact, both in the medical and economic aspects.

Aim:

Analyze the immediate postoperative complications comparing mesh versus non mesh hernioplasty.

Method:

Randomized control trial, with the enrollment of 263 patients underwent surgery for inguinal hernia randomized by randomization table. Treatment (mesh, Lichtenstein or without mesh, Bassini technique) was assigned using sequentially numbered opaque envelopes having fulfilled the inclusion criteria. The variables analyzed were: postoperative pain, seroma, hematoma, infection, return to normal activities and recurrence.

Results:

The mean age was 55.5 years, 88% patients were male and 12% female. The pain was higher in patients operated with mesh.

Conclusions:

The inguinal hernia repair mesh group had less immediate postoperative complications and significantly earlier return to work than hernioplasty without mesh, this being one of the most important conclusions.  相似文献   

19.

Background and Objectives:

Conversion to open surgery is an important problem, especially during the learning curve of laparoscopic totally extraperitoneal (TEP) inguinal hernia repair.

Methods:

Here, we discuss conversion to the Stoppa procedure during laparoscopic TEP inguinal hernia repair. Outcomes of patients who underwent conversion to an open approach during laparoscopic TEP inguinal hernia repair between September 2004 and May 2010 were evaluated.

Results:

In total, 259 consecutive patients with 281 inguinal hernias underwent laparoscopic TEP inguinal hernia repair. Thirty-one hernia repairs (11%) were converted to open conventional surgical procedures. Twenty-eight of 31 laparoscopic TEP hernia repairs were converted to modified Stoppa procedures, because of technical difficulties. Three of these patients underwent Lichtenstein hernia repairs, because they had undergone previous surgeries.

Conclusion:

Stoppa is an easy and successful procedure used to solve problems during TEP hernia repair. The Lichtenstein procedure may be a suitable option in patients who have undergone previous operations, such as a radical prostatectomy.  相似文献   

20.

Background and Objectives:

The recurrence rate after laparoscopic ventral hernia repair is lower than the rate of recurrence via the open approach in many series. Studies have demonstrated the safety and efficacy of this procedure but have had relatively young patient populations. We present our experience in a significantly older population.

Methods:

A retrospective chart review of all patients 80 to 89 years of age undergoing a laparoscopic ventral hernia repair at our institution from May 2000 to June 2007 was performed. Data collected included demographics, number and type of previous abdominal operations, number of previous hernia repairs, defect and mesh size, postoperative complications, and follow-up.

Results:

Twenty octogenarian patients underwent laparoscopic ventral hernia repair. Nine were men and 11 were women. The mean age was 82 years. Thirteen patients (65%) had one or more associated comorbidities at the time of surgery. Eighteen patients (90%) had undergone a mean of 1.7 prior abdominal operations. Six (30%) patients had undergone a mean of 1.1 previous open hernia repairs; 5 (83%) with mesh. Eight patients (40%) had an additional operative procedure at the time of laparoscopic hernia repair. Ten minor complications occurred in 10 patients (50%). Four major complications occurred in 4 patients (20%). One patient required reoperation for evacuation of hematoma at a trocar site. No patients complained of pain at a transabdominal suture site or persistent seromas by 6 weeks of follow-up. At mean follow-up of 3.1 months, no recurrences occurred and no patients required mesh removal in this series. No deaths occurred.

Conclusion:

Laparoscopic ventral hernia repair is becoming an accepted technique for hernia repair in the United States, with a well-documented low recurrence rate. Our series demonstrates that this approach is equally safe and effective for a significantly older segment of the population.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏