首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Objective:To evaluate whether overloading of teeth can be avoided by utilizing aligners with reduced thicknesses of 0.4 mm or 0.3 mm.Materials and Methods:The experimental setup included an acrylic maxillary jaw model with tooth 11 separated and fixed via a 3-D force-moment transducer to a hexapod for experimental movement. Aligners tested were fabricated on duplicate stone models using commercially available polyethylene terephthalate glycol (PET-G) foils with thicknesses between 0.5 and 0.75 mm, and novel 0.4-mm- and 0.3-mm-thick foils. With the test aligner seated, 11 was bodily displaced in a labiopalatal direction in the range of ±0.25 mm while all six force-and-moment components exerted on this tooth were registered.Results:With the thinnest commercially available 0.5-mm aligner, median forces of −7.89 N and 8.37 N were measured for the maximum 0.25-mm movement of 11 in a labial and palatal direction, respectively. In comparison, force values were 35% and 71% lower for the novel aligners with a thickness of 0.4 mm and 0.3 mm, respectively.Conclusions:Novel “leveling” aligners with reduced thickness may reduce overloading of individual teeth during aligner therapy. Due to form instability of 0.3-mm aligners, we suggest a novel sequence of 0.4–0.5–0.75 mm for aligner systems using several foil thicknesses for load graduation within single setup steps. This would combine low stiffness of the initial aligner and relatively constant load increases throughout the treatment.  相似文献   

2.
The aim of this review was to systematically appraise the evidence on aligner mechanics and forces and moments generated across difference types of aligners. In vitro‐ laboratory studies for model simulated tooth movement with aligners. Database searches within Medline via Pubmed, Cochrane Central Register of Controlled Trials (CENTRAL), LILACS via BIREME Virtual Health Library. Unpublished literature was also searched in Open Grey, ClinicalTrials.gov ( www.clinicaltrials.gov ), the National Research Register ( www.controlled-trials.com ) and Center for Open Science (Open Science Framework), using the terms “aligner” AND “orthodontic”. Risk of bias assessment was based on the Cochrane Risk of Bias tool. Random effects meta‐analyses were conducted. A total of 447 studies were identified through electronic search and after careful consideration of pre‐ defined eligibility criteria, 13 deemed eligible for inclusion, while 2 were included in the quantitative synthesis. When palatal tipping of the upper central incisor through PET‐G aligners was considered, aligner thickness of 0.5, 0.625 or 0.75 mm was not associated with a significantly different moment to force (M/F) ratio, given a common gingival edge width of 3‐4 mm. Aligner thickness does not appear to possess a significant role in forces and moments generated by clear aligners under specific settings, while the most commonly examined tooth movements are tipping and rotation. The findings of this review may be applicable to certain conditions in laboratory settings.  相似文献   

3.
4.
ObjectivesTo analyze the biomechanical system of anterior retraction with clear aligner therapy (CAT) with and without an anterior mini-screw and elastics.Materials and MethodsModels including a maxillary dentition (without first premolars), maxilla, periodontal ligaments (PDLs), attachments, and aligners were constructed and imported to finite element software. Three model groups were created: (1) control (CAT alone), (2) labial elastics (CAT with elastics between the anterior mini-screw and buttons on central incisors), and (3) linguoincisal elastics (CAT with elastics between the anterior mini-screw and precision cuts on the lingual sides of the aligner). Elastic forces (0–300 g, in 50 g increments) were applied.ResultsCAT alone caused lingual tipping and extrusion of the incisors. Labial elastics caused palatal root torquing and intrusion and mesial tipping of the central incisors, while linguoincisal elastics produced palatal root torquing and intrusion of both central and lateral incisors. Second premolars were intruded in all three groups, with less intrusion in the linguoincisal elastics group. For the control group, stress was concentrated on both labial and lingual root surfaces, alveolar ridge, and cervical and apical PDLs. Stress was more concentrated in the labial elastics group and less concentrated in the linguoincisal elastics group.ConclusionsCAT produced lingual tipping and extrusion of incisors during anterior retraction. Anterior mini-screws and elastics can achieve incisor intrusion and palatal root torquing. Linguoincisal elastics are superior to labial elastics with a lower likelihood of buccal open bite. Root resorption and alveolar defects may occur in CAT, more likely for labial elastics and less likely for linguoincisal elastics.  相似文献   

5.
Objectives

To evaluate the force delivered by removable thermoplastic appliances (RTAs, aligners), altered with Hilliard precision thermopliers, on an upper central incisor to tip it in the palatal and vestibular directions.

Materials and methods

A total of 10 aligners made from Ideal Clear® (polyethylene terephthalate glycol copolyester, PET-G) with a thickness of 1 mm were used in force analysis. Different-sized spot-thermoformed protuberances (bumps) were generated by activating the thermoplier (thin and thick) up to 30°, 60° and 90° in the centre of the palatal and vestibular surfaces of the aligner in 15° steps. The tipping (Fx) and intrusive (Fz) force components were measured on the isolated upper central incisor as part of a standardized resin model, with or without vertical loading by a weight equivalent.

Results

Thermoplier activation at 30°, 60° and 90° resulted in different bump heights. The analysis revealed significantly higher Fx and Fz values with increasing bump heights for every activation step in all cases (p?<?0.0001, respectively). Overall, the values of the Fx force component were higher than those observed for Fz. Significant differences between the palatal and vestibular tipping procedures were found depending on the resulting force components when the thin thermoplier was used; in contrast, the thick thermoplier resulted in a larger dispersion of the force magnitudes.

Conclusions

Aligners modified with Hilliard precision thermopliers showed altered biomechanical parameters. This approach could be an option for treatment modification.

Clinical relevance

The instrumental examination provided informative results for daily practice, as activation, force dosage and different force values under chewing pressure can be estimated more precisely based on the determined force levels.

  相似文献   

6.
Objective:To compare the mandibular incisor proclination produced by fixed labial appliances and third generation clear aligners.Materials and Methods:Patients underwent a course of orthodontic treatment using either fixed labial appliances or clear aligners (Invisalign). Mandibular incisor proclination was measured by comparing pretreatment and near-end treatment lateral cephalograms. Eligibility criteria included adult patients with mild mandibular incisor crowding (<4 mm) and Class I skeletal bases (ANB, 1–4°). The main outcome was the cephalometric change in mandibular incisor inclination to the mandibular plane at the end of treatment. Eligible patients picking a sealed opaque envelope, which indicated their group allocation, was used to achieve randomization. Data was analyzed using a Welch two-sample t-test.Results:Forty-four patients (mean age, 26.4 ± 7.7 years) were randomized in a 1:1 ratio to either the fixed labial appliance or the clear aligner group. Baseline characteristics were similar for both groups: Fixed appliance mean crowding was 2.1 ± 1.3 mm vs clear aligner mean crowding, 2.5 ± 1.3 mm; pretreatment mean mandibular incisor inclination for the fixed appliance group was 90.8 ± 5.4° vs 91.6 ± 6.4° for the clear aligner group. Fixed appliances produced 5.3 ± 4.3° of mandibular incisor proclination. Clear aligners proclined the mandibular incisors by 3.4 ± 3.2°. The difference between the two groups was not statistically significant (P > .05).Conclusion:There was no difference in the amount of mandibular incisor proclination produced by clear aligners and fixed labial appliances in mild crowding cases.  相似文献   

7.
Objectives:The fitting of aligners on anchorage teeth is a crucial factor in clear aligner orthodontics. The purpose of this experimental study was to evaluate the fitting of two aligner systems, Invisalign and CA-Clear Aligner, using scanning electron microscopy (SEM).Materials and Methods:Passive aligners (Invisalign and CA-Clear Aligner) were adapted on resin casts obtained by stereolithography (STL) files of a patient, and then sectioned buccolingually. Upper and lower central incisors, upper and lower first premolars, and upper and lower first molars were the regions analyzed. Representative microphotographs of sections were taken with a scanning electron microscope (SEM); a total of 160 micrometric measurements were obtained and analyzed with ANOVA tests.Results:Invisalign provided an overall better fit on lower incisors (F = 11.48, P = .0095) and on lower molars (F = 19.93, P = .0012). Considering the different regions, Invisalign provided better fit at the gingival edge of the buccal aspect on lower incisors (F = 11.33, P = 0.0056) and at the gingival edge of the lingual aspect on upper premolars (F =5.34, P = 0.0047). On the upper molars, Invisalign provided better fit at the gingival edge of the buccal aspect, while CA-Clear Aligner provided better fit at the buccal maximum convexity, on the buccal cusp, on the occlusal groove and at the palatal cusp. On lower molars, Invisalign showed a more accurate fit at the buccal aspect points.Conclusions:Invisalign and CA-Clear Aligner exhibited comparable fit on anchorage teeth. Invisalign provided better fit at the gingival edges of aligners, while the CA-Clear Aligner provided better fit on complex occlusal surfaces.  相似文献   

8.
Background There is no scientific evidence supporting the choice of a palatal stent in patients who underwent removal of an impacted supernumerary tooth. We aimed to investigate the effects of palatal stents in patients who underwent supernumerary tooth removal through a palatal approach and to suggest the optimal stent thickness and material.Material and Methods We recruited 144 patients who underwent extraction of a supernumerary tooth between the maxillary anterior teeth. Subjects were assigned to a control group (CG) or one of four compressive palatal stent groups (CPSGs) classified by the thickness and material of the thermoplastic acrylic stent used. Palatal gingival swelling and objective indices (healing, oral hygiene, gingival, and plaque) were evaluated before surgery and on postoperative days (PODs) 3, 7, and 14; pain/discomfort and the Child Oral Health Impact Profile (COHIP) were assessed as subjective indices of the effects of the stent.Results The CPSGs showed faster healing than did the CG on PODs 7 (P<0.001) and 14 (P=0.043); swelling was measured by 1.64±0.88 mm and 4.52±0.39 mm, respectively. Although swelling was least in the 4-mm hard group (0.92±0.33 mm), the difference compared with that in the 2-mm hard group (1.01±0.18 mm) was not significant (P=0.077). The CPSGs showed better COHIP (P<0.001-0.036) and pain scores (P<0.001) than did the CG on PODs 1-3.Conclusions Compressive palatal stents reduce discomfort by decreasing pain and alleviating swelling. Although a stent is effective regardless of its thickness and material, 2-mm hard stents maximized such positive effects with minimal discomfort. Key words:Supernumerary tooth, tooth Extraction, postoperative care, oral Health, pediatric dentistry.  相似文献   

9.
Objectives:To investigate the relationships among different intrusion patterns of clear overlay aligners and the corresponding orthodontic forces and to provide guidance for clinical treatment.Materials and Methods:Five sets of removable thermoplastic-formed aligners with the same thickness, designed for different intrusion procedures (G0 aligners as a control group, with no activation; G1 aligners for intruding canines; G2 aligners for intruding incisors; G3 aligners for intruding canines and incisors with the same activations; G4 aligners for intruding canines and incisors with different activation), were manufactured, and the corresponding intrusion forces were measured with a multiaxis force/torque transducer measurement system in real time.Results:With the same activation (0.2-mm intrusion) and rectangular attachments placed on the premolars and first molars, the canines experienced the largest intrusive force when intruded alone using G1 aligners. The canines received a larger intrusive force than incisors in G3. The incisors received similar forces in G2 and G3. First premolars endured the largest extrusive forces when all anterior teeth were intruded with G3 aligners. Extrusion forces were exerted on canines and lateral incisors when using G4 aligners.Conclusions:Aligners with different intrusion patterns exert different forces on incisors, canines, and premolars, and the forces were closely related to the designed activation, shape and position of the attachment and relative movement of the adjacent teeth.  相似文献   

10.
目的:应用双膜透明矫治器对兔下颌中切牙进行正畸移动,评价双膜透明矫治器移动牙的效果。方法:选用6只新西兰大白兔,实验组为双膜透明矫治器加力组(3只),设计戴用3步矫治器,每一步牙移动0.33 mm,先戴用薄膜透明矫治器2 d,再戴用厚膜透明矫治器2 d;对照组为常规厚度膜片透明矫治器加力组(3只),设计戴用3步矫治器,每一步牙移动0.20 mm,每步矫治器戴4 d。在每组兔分别戴用第1、2和3步矫治器后制取模型,测量牙移动数据。采用SPSS 19.0软件包对数据进行统计学分析。结果:2组牙移动表达的精确度从牙冠切端向龈端逐渐降低,实验组的精确度随矫治时间增加呈下降趋势,而对照组的精确度随矫治时间增加无明显变化。实验组牙冠切端、中端和龈端牙移动速率均显著大于对照组(P<0.001)。结论:兔下颌中切牙在透明矫治器的作用下产生倾斜移动。采用双膜透明矫治器矫治,牙移动速率加快,但牙移动表达的精确度降低。  相似文献   

11.
Objective:To determine the forces and moments delivered to a maxillary central incisor during rotation by three different thermoplastic appliances with identical thickness.Materials and Methods:Five identical appliances were manufactured from each of three materials (Ideal Clear 1.0 mm, Erkodur 1.0 mm, Biolon 1.0 mm). An upper central incisor fixed in a measuring device was rotated around its central axis in 0.5-degree steps to ±2.5 degrees, ±5 degrees, and ±7.5 degrees (equivalent to an activation of ±0.17 mm, ±0.34 mm, and ±0.51 mm of the incisor edge) in the clockwise and anticlockwise directions with the respective appliance fixed in place. For statistical analysis, the moments Tz (rotation) and forces Fz (intrusion) were tested. Means and standard deviations for Tz and median and 25% and 75% quantiles for Fz were calculated. An analysis of variance (ANOVA) was performed.Results:The minimal moment was determined at a rotation of −0.17 mm (−7.3 Nmm, ±0.8), and the maximal moment at a deflection of −0.51 mm (−71.8 Nmm. ±2.5) was recorded. The minimal value for Fz was measured at an activation of −0.17 mm (0.0 N), and the highest intrusive forces were evaluated for a rotation of −0.51 mm (−5.8 N). The particular material sometimes had a significant (P < .05) influence on the forces delivered and the moments.Conclusions:During rotation with aligners, an intrusive force can also be observed. The direction of rotation, and the materials used all exert an influence on the force delivery properties of the appliance.  相似文献   

12.
Objective:To compare alveolar bone thickness and height changes between untreated incisors (control), incisors advanced with light-force tipping, and incisors advanced with bodily movement mechanics.Materials and Methods:Forty-three subjects (aged 9.49 ± 1.56 years) with anterior crossbite were allocated into an untreated group (control), tipping group, or bodily movement group. Lateral cephalograms were taken before advancement (T0) and after obtaining normal overjet (T1). Changes in labial and palatal alveolar bone thickness and height surrounding maxillary incisors were evaluated with limited field-of-view cone-beam computed tomography before advancement (CT0) and 4 months after normal overjet was obtained (CT1). Wilcoxon matched-pairs signed-rank and Kruskal-Wallis one-way ANOVA tests were used to compare changes within and between groups, as appropriate. The significance level was set at .05.Results:Labial alveolar bone thickness at the midroot and apical levels were significantly decreased in the bodily movement group (P < .05). However, between groups, there was no statistically significant difference in labial bone thickness changes at any level. Palatal and total alveolar bone thickness at the midroot and apical levels were significantly decreased in the tipping group compared with the control and bodily movement groups (P < .05). Neither labial nor palatal bone height changes were significantly different among groups.Conclusions:Maxillary incisor advancement with light-force tipping and bodily movement in growing patients resulted in labial alveolar bone thickness and labial and palatal alveolar bone height changes that were similar to the untreated group.  相似文献   

13.
《Saudi Dental Journal》2023,35(3):255-262
ObjectiveThe study was conducted to investigate the thickness and height of the alveolar bone of individual teeth after slow maxillary expansion (SME) with quad helix or clear aligner appliances and hypothesized that there is no difference in buccal alveolar bone thickness or heights in patients treated by either quad helix or clear aligners.Material and MethodsThis is a retrospective study; the records of 22 patients treated between December 2019 to April 2020 by dental arch expansion using either clear aligners or quad helix appliances were retrieved and studied. The results obtained through cone beam computed tomography (CBCTs) before and immediately after maxillary expansion (2 + 1 mm per side) were analyzed (11 in the Quad Helix group and 11 in the clear aligner). The data collected was analyzed using linear and angular measurements obtained through On-demand 3D App software. Furthermore, Statistical Package for Social Sciences (SPSS) version 25.0 was used to present the findings by mean and standard deviations, and Scheffe’s test was applied for comparing forces.ResultsThe results showed that the mean age of patients in the clear aligner group and Quad Helix was 16.27 ± 0.56 years and 15.5 ± 1.53 years, respectively. There was no difference in buccal alveolar bone thickness or heights in patients treated by either quad helix or clear aligners. This is due to the findings that suggest that there was a decrease in bone height and bone width when treated with a quad helix as compared to clear alignment.ConclusionIt can be concluded that the quad helix SME treatment affects alveolar bone integrity; therefore, clear aligners might be better for treating patients than the quad helix.  相似文献   

14.
Objectives:To compare tooth movement achieved, time required for alignment, root resorption, and alveolar bone thickness changes during initial dental alignment between groups treated with 0.012-inch preformed heat-activated or customized nickel titanium (NiTi) archwires.Materials and Methods:Thirty-two subjects (mean age 19.8 ± 1.7 years) with severe crowding of maxillary anterior teeth had premolar extractions and were randomly allocated into control and experimental groups receiving preformed heat-activated and customized NiTi archwires, respectively. Limited field of view cone-beam computed tomographies were taken initially (T0) and three months after final alignment (TF) to evaluate bone changes. Digital model analysis assessed tooth movement at monthly intervals. Time to achieve alignment was assessed in months. Wilcoxon signed-rank tests and Mann–Whitney U-tests were used to compare changes within and between groups, as appropriate.Results:Central incisor tooth movement was significantly different (all P ≤ .003) between groups at all time points. TF-T0 showed labial movement (0.75 ± 1.42 mm) in the control group and palatal movement (−0.96 ± 0.41 mm) in the experimental group. The experimental compared to control group showed significantly more canine distal movement (0.60 ± 0.28 mm; P ≤ .049), less labial bone thickness changes (P ≤ .004), less root resorption of the central and lateral incisors (P ≤ .007), and a longer time to achieve alignment (P = .01).Conclusions:The experimental group exhibited palatal movement of the central incisors, more canine distal movement with less bone thickness changes, and less root resorption but took more time to achieve alignment than the control group.  相似文献   

15.
Objective:To investigate differences in case selection, treatment management, and aligner treatment expertise between orthodontists and general practitioners.Materials and Methods:A parallel pair of original surveys with three sections (case selection, treatment management, and demographics) was sent to orthodontists (N = 1000) and general dentists (N = 1000) who were providers of aligner treatment.Results:Orthodontists had treated significantly more patients with aligners, had treated more patients with aligners in the previous 12 months, and had received more aligner training than general dentists (P < .0001). In general, case confidence increased with increasing experience for both orthodontists and general dentists. After adjusting for experience, there was a significant difference in aligner case confidence between orthodontists and general dentists for several malocclusions. General dentists were more confident than orthodontists in treating deep bite, severe crowding, and Class II malocclusions with aligners (P ≤ .0001). Significant differences were also found for all treatment management techniques except interproximal reduction.Conclusion:There was a significant difference in case selection, treatment management, and aligner expertise between orthodontists and general dentists, although the differences in case selection were small. Overall, it was shown that orthodontists and general dentists elected to treat a variety of moderate to severe malocclusions with aligners but with different utilization of recommended auxiliaries, perhaps demonstrating a difference in treatment goals.  相似文献   

16.
ObjectivesTo investigate the prevalence and severity of external apical root resorption (EARR) volumetrically with clear aligner therapy using cone-beam computed tomography (CBCT) as well as determine the possible risk factors and develop a prediction model for EARR.Materials and MethodsIn this retrospective study, 320 incisors from 40 Class II patients treated with aligners (Invisalign) were included in this study. CBCT images were obtained at pretreatment (T0) and posttreatment (T1). Root volume was calculated by three-dimensional reconstruction of CBCT images, and apical tooth movement was measured from superimposed CBCT images. Changes in root volume were compared using paired t-tests, and the relationship between root volume loss and potential risk factors was analyzed by multiple linear regression.ResultsAll of the measured incisors showed root volume loss, with an average of 11.48 ± 6.70 mm3, and the prevalence of severe resorption was 0.625%. The prediction model for EARR included variables of posttreatment sagittal root position (SRP), extraction, tooth type, and apical intrusion and extrusion displacements, with an R2 of 0.51. Age, sex, duration, pretreatment SRP, attachment, advancement, and retraction movements were excluded from the model.ConclusionsMost incisors showed mild to moderate resorption during aligner treatment; only a minimal percentage showed severe resorption. Posttreatment SRP (which showed the highest association with EARR), extraction, tooth type, and apical intrusion and extrusion displacements were risk factors for EARR.  相似文献   

17.
ObjectivesTo evaluate tooth movements during maxillary arch expansion with clear aligner treatment.Materials and MethodsThe study group included 28 subjects (16 females, 12 males, mean age 31.9 ± 5.4 years) collected prospectively from January 2018 to May 2019. Inclusion criteria were European ancestry, posterior transverse discrepancy of 3–6 mm, permanent dentition stage, presence of second permanent molars, mild or moderate crowding, and good compliance with aligners. Treatment protocol included nonextraction strategies, application of Invisalign clear aligner system, and no auxiliaries other than Invisalign attachments. Linear and angular measurements were performed before treatment (T1), at the end of treatment (T2), and on final virtual models (T2 ClinCheck). A paired t-test was used to compare T2-T1 and T2-T2 ClinCheck changes. The level of significance was set at 5%.ResultsStatistically significant differences were found for all measurements, except for ones at the upper second molars. The greatest increase in maxillary width was detected at the upper first and second premolars: +3.5 mm for the first premolar and +3.8 mm for the second premolar at T2. Comparison of T2-T1 angular outcomes showed statistically significant changes in the inclinations of all teeth except for the second permanent molars. T2-T2 ClinCheck showed significant differences for both linear and angular measurements for maxillary canines, resulting in poor predictability.ConclusionsMaxillary arch development revealed a progressive reduction of the expansion rate and buccal tipping in the anterior, lateral, and posterior regions, with the greatest net increase at the first and second premolars. Clinical attention should be paid to maxillary canine movements, and overcorrection should be planned for them during dentoalveolar expansion.  相似文献   

18.
Objective:To investigate changes in maxillary alveolar bone thickness after maxillary incisor proclination and extrusion during anterior crossbite correction in a group of growing patients with Class III malocclusion.Materials and Methods:Maxillary incisors of 15 growing patients with anterior crossbite were proclined and extruded with 0.016″ beta-titanium advancing loops and Class III elastics. Lateral cephalograms were recorded before advancement (T0) and 4 months after a normal overjet and overbite were achieved (T1). Changes in alveolar bone thickness surrounding the maxillary incisors at the crestal (S1), midroot (S2), and apical (S3) levels were measured using cone-beam computed tomography (CBCT). Paired t-tests were used to determine the significance of the changes. A Spearman rank correlation analysis was performed to explore the relationship between thickness changes and the rate and amount of incisor movements.Results:Although statistically significant decreases were observed in palatal and total bone thickness at the S2 and S3 level (P < .05), the amounts of these changes were clinically insignificant, ranging from 0.34 to 0.59 mm. Changes in labial bone thickness at all levels were not significant. Changes in palatal bone thickness at S3 were negatively correlated with changes in incisor inclination. (r  =  −0.71; P < .05).Conclusion:In a group of growing patients with Class III malocclusion undergoing anterior crossbite correction, controlled tipping mechanics accompanied by extrusive force may produce successful tooth movement with minimal iatrogenic detriment to the alveolar bone.  相似文献   

19.
ObjectiveTo assess the efficacy and efficiency of treatment in adolescents presenting with mild malocclusions, comparing outcomes using clear aligners to fixed appliances.Materials and MethodsPatients identified retrospectively and consecutively from one private practice had been treated with either clear aligners (Invisalign, Align Technology, Santa Clara, Calif) or fixed appliances (0.022 Damon, Ormco, Orange, Calif; n = 26/group). Assessments of occlusion were made using the American Board of Orthodontics Discrepancy Index (DI) for initial records and Cast-Radiograph Evaluation (CRE) for final records. Number of appointments, number of emergency visits, and overall treatment time were determined from chart reviews. Data were analyzed using Pearson''s correlation, Wilcoxon rank tests, unpaired t-tests, and Chi-square tests, with significance set to P ≤ .05.ResultsPretreatment, the aligner and fixed groups showed no significant difference in overall severity (DI: 11.9 ± 5.3 vs 11.6 ± 4.8) or in any individual DI category. Posttreatment scores showed finishes for the aligner group had fewer discrepancies from ideal relative to the fixed appliance group (CRE: 30.1 ± 8.3 vs 37.0 ± 9.3; P < .01). Patients treated with aligners had fewer appointments (13.7 ± 4.4 vs 19.3 ± 3.6; P < .0001), fewer emergency visits (0.8 ± 1.0 vs 3.6 ± 2.5; P < .0001), and shorter overall treatment time (16.9 ± 5.7 vs 23.4 ± 4.4 months; P < .0001).ConclusionsOutcomes for treatment of mild malocclusions in adolescents showed equivalent effectiveness of clear aligners compared to fixed appliances, with significantly improved results for clear aligner treatment in terms of tooth alignment, occlusal relations, and overjet. Assessment of the number of appointments, number of emergency visits, and overall treatment time showed better outcomes for treatment with clear aligners.  相似文献   

20.
Objective:To measure the forces delivered by thermoplastic appliances made from three materials and investigate effects of mechanical properties, material thickness, and amount of activation on orthodontic forces.Materials and Methods:Three thermoplastic materials, Duran (Scheu Dental), Erkodur (Erkodent Erich Kopp GmbH), and Hardcast (Scheu Dental), with two different thicknesses were selected. Values of elastic modulus and hardness were obtained from nanoindentation measurements at 28°C. A custom-fabricated system with a force sensor was employed to obtain measurements of in vitro force delivered by the thermoplastic appliances for 0.5-mm and 1.0-mm activation for bodily tooth movement. Experimental results were subjected to several statistical analyses.Results:Hardcast had significantly lower elastic modulus and hardness than Duran and Erkodur, whose properties were not significantly different. Appliances fabricated from thicker material (0.75 mm or 0.8 mm) always produced significantly greater force than those fabricated from thinner material (0.4 mm or 0.5 mm). Appliances with 1.0-mm activation produced significantly lower force than those with 0.5-mm activation, except for 0.4-mm thick Hardcast appliances. A strong correlation was found between mechanical properties of the thermoplastic materials and force produced by the appliances.Conclusions:Orthodontic forces delivered by thermoplastic appliances depend on the material, thickness, and amount of activation. Mechanical properties of the polymers obtained by nanoindentation testing are predictive of force delivery by these appliances.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号