首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
PURPOSE: The purpose of this study was to compare defect extent and severity and myocardial uptake with exercise and pharmacologic stress with technetium-99m (Tc-99m) tetrofosmin tomographic myocardial perfusion imaging. BACKGROUND: Detection of stress-induced myocardial perfusion defects depends on both a disparity in blood flow between normal and stenotic vessels and the extraction fraction and linearity of myocardial uptake of the tracer. There are limited clinical data for exercise or pharmacologic stress with Tc-99m tetrofosmin tomographic myocardial perfusion imaging. METHODS: Thirty-one patients with coronary artery disease and 7 with a < 5% likelihood of coronary artery disease underwent on separate days Tc-99m tetrofosmin single-photon emission computed tomographic imaging at rest and after exercise, dipyridamole, adenosine, and dobutamine stress. Images were interpreted by a blinded consensus of 3 experienced readers with a 17-segment model and 5-point scoring system. RESULTS: Compared with exercise, the summed stress score was smaller with dipyridamole (P < .01), and the reversibility score was smaller with both dipyridamole (P < .01) and dobutamine (P < .05), whereas the number of abnormal and reversible segments was less with both dipyridamole (P < .01 and P < .001, respectively) and dobutamine (both P < .05). No significant differences were found in the summed stress or reversibility scores and the number of abnormal or reversible segments between exercise and adenosine. CONCLUSIONS: Compared with exercise, defect extent, severity, and reversibility are less with dipyridamole and dobutamine with Tc-99m tetrofosmin single photon emission computed tomographic imaging.  相似文献   

2.
3.
During the past decade progress in the field of myocardial perfusion imaging has resulted in a myriad of choices for perfusion imaging protocols, including choices in types of stressor, imaging modality, perfusion tracer, method of analysis, and a wide range of choices of imaging protocols. This review will examine this latter aspect in the context of choices of perfusion tracers that are now available for wide use. Manipulations of thallium protocols have revolved primarily around optimizing identification of stress defect reversibility and regional myocardial viability. The high image quality and long retention time afforded by the technetium-labeled agents allow the potential for streamlining imaging protocols to maximize efficiency and cost-effectiveness, such as performing stress only imaging in a subset of patients and performing simultaneous assessment of perfusion and function.  相似文献   

4.

Background.

The favorable prognostic significance of normal201Tl stress perfusion images, even in the presence of known coronary artery disease, has been well documented. Relatively few data are available with regard to the prognostic significance of normal planar and single-photon emission computed tomographic (SPECT) stress99mTc-labeled sestamibi (99mTc-sestamibi) images.

Methods and Results.

The prognostic significance of normal exercise99mTc-sestamibi myocardial perfusion imaging was evaluated in 208 consecutive patients. All patients were referred for evaluation of chest pain syndrome. One hundred eight patients (52%) underwent SPECT imaging, 79 patients (38%) underwent planar imaging, and 21 patients (10%) underwent both planar and SPECT imaging. One hundred seventy-five patients (84%) had a normal or nondiagnostic exercise electrocardiogram, and 33 patients (16%) had a positive exercise electrocardiogram. Follow-up was 13.5 ±2 months and was complete in 99.5% of patients. No patient died of cardiac causes during follow-up. One patient (0.5%) had a nonfatal myocardial infarction and four patients (2%) had unstable angina necessitating revascularization. There was no difference in rate of cardiac events between men and women or whether SPECT or planar imaging was used. However, 33 patients with normal99mTc-sestamibi imaging and a positive exercise electrocardiogram had a significantly higher cardiac event rate than had patients with negative exercise electrocardiograms (9% vs 1%,p < 0.025).

Conclusion

Patients with normal99mTc-sestamibi exercise SPECT or planar imaging results and a normal or nondiagnostic exercise electrocardiogram have a favorable 1-year prognosis. Patients with normal99mTc-sestamibi images and a positive stress electrocardiogram have a less favorable outcome.  相似文献   

5.

Background

This study was a direct comparison of the imaging characteristics of 99mTc-labeled Q12 (99mTc-Q12) and 99mTc-labeled Q3 (99mTc-Q3) in the same patients.

Methods and Results

In 10 patients with known angiographic coronary artery anatomy, 99mTc-Q12 and 99mTc-Q3 myocardial imaging were performed. Tomographic myocardial imaging was started 15 minutes after tracer injection at rest and with treadmill exercise. Ratios of heart-to-lung and heart-to-liver activity were calculated from the anterior plane projections of the tomograms at 20 minutes after tracer injection. The presence or absence of angiographic coronary artery disease was correctly determined from 99mTc-Q12 images in 10 of 10 patients with 99mTc-Q12 and in 9 of 10 patients with 99mTc-Q3. The presence or absence of a greater than 50% stenosis in an individual coronary vessel was correctly predicted for 26 of 30 vessels with 99mTc-Q12 (87%) and in 27 of 30 vessels with 99mTc-Q3 (90%, p=NS vs 99mTc-Q12). Mean heart-to-lung activity ratio at rest was 1.50 for 99mTc-Q12 and 1.93 for 99mTc-Q3 (p<0.01). Mean heart-to-liver activity ratio at rest for 99mTc-Q12 was 0.78 versus 0.54 for 99mTc-Q3 (p<0.0001).

Conclusions

In 10 patients with chest pain and angiographically defined coronary anatomy, 99mTc-Q12 and 99mTc-Q3 provided similar detection of coronary artery stenoses. At 20 minutes after tracer injection, heart-to-liver activity ratios were more favorable for 99mTc-Q12 than for 99mTc-Q3, but 99mTc-Q3 resulted in a more favorable ratio of heart-to-lung activity.  相似文献   

6.
BACKGROUND: Observer variability has been shown with interpretation of planar thallium-201 images. The interpretive reproducibility of technetium-99m sestamibi tomographic imaging is unknown. This study evaluated the interpretive reproducibility of interpretable Tc-99m sestamibi tomographic images among nuclear cardiologists with a wide range of training and experience. METHODS: Three experienced readers (EX) and 3 less-experienced readers (LEX) interpreted 138 exercise and rest Tc-99m sestamibi tomographic images (101 were abnormal in patients with coronary artery disease [CAD], 37 were normal in patients with <5% likelihood of CAD) twice in random sequence without clinical data. Images of good to excellent quality were randomly selected from a database at 2 nuclear cardiology laboratories. Intraobserver and interobserver agreement for global, left anterior descending (LAD) territory, non-LAD first (normal/abnormal) and second (normal/fixed/reversible) order, and defect extent (normal/single-vessel CAD/multi-vessel CAD) were assessed with percent agreement and Cohen's kappa (kappa) statistic. RESULTS: With regard to intraobserver agreement, first and second order ranged from 87% to 94% and 80% to 90% for global, 82% to 96% and 78% to 95% for LAD, and 88% to 91% and 80% to 90% for non-LAD, respectively. Defect extent ranged from 75% to 90%. There were no differences between EX and LEX for global and non-LAD first and second order, LAD first order, and defect extent. LAD second order was 93% for EX compared with 88% (P = .015) for LEX. With regard to interobserver agreement, first and second order ranged from 73% to 89% and 64% to 85% for global, 73% to 93% and 69% to 91% for LAD, and 76% to 88% and 68% to 84% for non-LAD, respectively. Defect extent ranged from 61% to 82%. Global first and second order ranged from 85% to 87% and 78% to 82% for EX compared with 73% to 84% and 64% to 79% for LEX. LAD first and second order ranged from 89% to 91% and 88% to 89% for EX compared with 73% to 91% and 69% to 70% for LEX. Non-LAD first and second order ranged from 82% to 86% and 76% to 77% for EX compared with 76% to 86% and 68% to 81% for LEX. Defect extent ranged from 69% to 75% for EX compared with 59% to 77% for LEX. CONCLUSIONS: There is moderate to excellent interpretive reproducibility with stress Tc-99m sestamibi SPECT imaging among nuclear cardiologists with a wide range of training and experience.  相似文献   

7.
The accuracy of technetium-99m human immunoglobulin (HIG) for the detection of chronic osteomyelitis (OM) was compared with white blood cell scintigraphy using99mTc-labelled monoclonal mouse antibodies (MAB). Seventeen patients suspected of having OM in 20 lesions went through three-phase skeletal scintigraphy, HIG scintigraphy and MAB scintigraphy. The final diagnosis was established by open surgery, histology and bacteriology. Chronic OM was proved in 14/20 lesions. Six of these 14 infections were located in peripheral areas without active bone marrow and 8/14 in central areas with active bone marrow. In peripheral OM, 5/6 with HIG and 6/6 with MAB were true positives. In the central skeleton all 8/8 infections appeared as cold lesions in the MAB study, which were defined as being false negative due to their non-specificity. Using HIG, 5/8 central infections were determined to be truly positive by showing photon-rich lesions. These 5 lesions were located in the hip region and in the pelvis, whereas 3 lesions of the spine were missed. There were no false-positive results in either studies. In conclusion, MAB was superior to HIG in peripheral OM concerning sensitivity, anatomical landmarks and differentiation of soft tissue versus bone infection. In central OM MAB detected all lesions accurately, but no differential diagnosis was possible due to the non-specificity of photon-low areas. In this respect HIG seems to be more specific due to the increased accumulation even in central infection sites.  相似文献   

8.
The aim of the study was to compare the accuracy of technetium-99m sestamibi imaging for localization of ectopic parathyroid glands in patients with hyperparathyroidism with that of magnetic resonance (MR) and computed tomographic (CT) imaging. Eleven patients with primary (n=3) or secondary (n=8) hyperparathyroidism were studied with99mTc sestamibi parathyroid imaging CT and MR imaging. Images of the neck were acquired at 10 min and 2–3 after tracer injection. The three patients with primary hyperparathyroidism and five patients with secondary hyperparathyroidism underwent parathyroidectomy. The ectopic glands were confirmed by histopathological examination of the resected specimens. In respect of 20 parathyroid glands in the eight patients explored surgically, the sensitivity and specificity of sestamibi imaging were 70% (14/20) and 88%, respectively, those of CT, 40% (8/20) and 88%, and those of MR imaging, 60% (12/20) and 88%. Of these patients, three had parathyroid adenomas while five had hyperplasia (17 glands). Sestamibi imaging localized eight ectopic parathyroid glands, which were surgically confirmed (six were located in the thymus and two in the mediastinum). In one patient explored surgically, the ectopic gland was located outside the field of the MR coil. Although the remaining three cases of secondary hyperparathyroidism were not confirmed surgically, these patients demonstrated sestamibi uptake in five parathyroid glands, including three ectopic glands. MR images demonstrated abnormal parathyroid glands in the same regions as sestamibi imaging. Our data indicate that99mTc-sestamibi imaging should be used initially to localize the ectopic parathyroid glands in patients with hyperparathyroidism for anatomical guidance prior to MR or CT imaging.  相似文献   

9.

Background

Both thallium 201 and technetium 99m sestamibi have been used to quantitate infarct size at rest. Exercise201Tl scintigraphy has been shown to have powerful prognostic information after myocardial infarction. A single study using these agents that could provide data on infarct size and prognosis would be of value. The purpose of this study was to compare estimates of infarct size by use of201Tl and99mTc sestamibi and to correlate these measurements with left ventricular ejection fraction in patients after acute myocardial infarction.

Methods and Results

The study group consisted of 20 patients who underwent low-level201Tl stress studies with reinjection and99mTc sestamibi resting studies within 4 days. Acute reperfusion was attempted in 18 of 20 patients. For99mTc sestamibi tomographic imaging, infarct size was quantitated with 60% of maximal counts per slice for five short-axis slices as described in multiple previous studies. The postreinjection delayed201Tl images acquired 4 hours after stress were quantitated according to the same threshold method.201Tl patient images were also quantitated with a commercially available polar map program and compared with sex-matched control subjects. Ejection fraction was determined for each patient by radionuclide ventriculography 6 weeks later. Ejection fraction was well preserved for the group: mean 0.53±0.10. Infarct size with99mTc sestamibi was 12%±13% of the left ventricle, which was significantly smaller than either method with201Tl: threshold method, 29%±18% of left ventricle; polar map method, 25%±17% of left ventricle (both201Tl estimates,p<0.0001 vs99mTc sestamibi;201Tl, 70% threshold vs201Tl polar map,p=0.04). There was a significant correlation between infarct size with99mTc sestamibi and that with201Tl (r=0.72 to 0.73;p<0.001). Infarct size with99mTc sestamibi, however, provided the closest correlation with ejection fraction (r=0.81;p<0.001), with the two201Tl quantitative methods providing very similar correlations (r=0.69;p<0.001).

Conclusions

Infarct size with reinjection201Tl imaging correlates significantly with resting infarct size with99mTc sestamibi, although it provides significantly larger estimates. Although both approaches can be combined with a same-day exercise protocol, the closer correlation of infarct size with ejection fraction at 6 weeks suggests that resting infarct size with99mTc sestamibi may be slightly more accurate.  相似文献   

10.

Background

Technetium 99m sestamibi (2-methoxyisobutyl isonitrile [MIBI]) is a relatively new radiopharmaceutical with improved imaging characteristics for exercise myocardial perfusion studies compared with thallium 201. Although increased lung uptake of201Tl has been shown to have important clinical significance, reflecting severity of coronary artery disease and left ventricular function, the factors affecting MIBI lung uptake are unknown. Therefore we examined the potential clinical, exercise, hemodynamic, myocardial perfusion, and ventricular function determinants of lung uptake of MIBI on exercise myocardial perfusion studies.

Methods and Results

The study cohort consisted of 103 patients referred for evaluation of coronary artery disease with exercise MIBI myocardial perfusion imaging. All patients underwent both a standard 1-day rest-stress MIBI planar imaging protocol and rest echocardiography. With the anterior-view stress images obtained 1 hour after MIBI injection, regions of interest were drawn over peak lung and myocardial activities and a lung/heart ratio was calculated. Multivariate regression analysis was used to relate the lung/heart ratio to clinical, exercise and hemodynamic, myocardial perfusion, and echocardiographic left ventricular function scores. We found no significant relation between lung/heart ratio and any patient variable.

Conclusions

Unlike201Tl, lung uptake of MIBI is not related to indexes of exercise, left ventricular dysfunction, or perfusion abnormalities. Thus MIBI lung uptake does not appear to have the same clinical significance as201Tl lung uptake.  相似文献   

11.
The accuracy of technetium-99m human immunoglobulin (HIG) for the detection of chronic osteomyelitis (OM) was compared with white blood cell scintigraphy using 99mTc-labelled monoclonal mouse antibodies (MAB). Seventeen patients suspected of having OM in 20 lesions went through three-phase skeletal scintigraphy, HIG scintigraphy and MAB scintigraphy. The final diagnosis was established by open surgery, histology and bacteriology. Chronic OM was proved in 14/20 lesions. Six of these 14 infections were located in peripheral areas without active bone marrow and 8/14 in central areas with active bone marrow. In peripheral OM, 5/6 with HIG and 6/6 with MAB were true positives. In the central skeleton all 8/8 infections appeared as cold lesions in the MAB study, which were defined as being false negative due to their non-specificity. Using HIG, 5/8 central infections were determined to be truly positive by showing photon-rich lesions. These 5 lesions were located in the hip region and in the pelvis, whereas 3 lesions of the spine were missed. There were no false-positive results in either studies. In conclusion, MAB was superior to HIG in peripheral OM concerning sensitivity, anatomical landmarks and differentiation of soft tissue versus bone infection. In central OM MAB detected all lesions accurately, but no differential diagnosis was possible due to the non-specificity of photon-low areas. In this respect HIG seems to be more specific due to the increased accumulation even in central infection sites.  相似文献   

12.
Background  There are limited data addressing the outcome of patients with normal or near normal myocardial perfusion during chest pain at rest. The purpose of this study was to determine the prognosis of patients with spontaneous chest pain, a normal or nondiagnostic electrocardiogram, no enzymatic evidence of myocardial infarction, and no evidence of severe resting ischemia by quantitative technetium 99m (99mTc) sestamibi imaging. Methods  In the study, 111 patients who fulfilled the above criteria were injected with 99mTc sestamibi during resting chest pain and were followed for a median 2.7 years. Of the patients in the study group, 58% had coronary artery disease that was documented by clinical history or coronary angiography. Tomographic 99mTc perfusion images were interpreted with a quantitative threshold technique initially developed to detect severely hypoperfused myocardium. The images were also interpreted qualitatively to detect patients with milder degrees of hypoperfused myocardium. Results  During follow-up 3 patients had cardiac deaths, 5 had nonfatal myocardial infarctions, and 21 underwent revascularization procedures (13 within 3 months and 8 more than 3 months after the sestamibi study). At 3 years, survival free of cardiac death was 97%, survival free of cardiac death or myocardial infarction was 91%, and survival of cardiac death, myocardial infarction, or late revascularization was 82%. Quantitative analysis of the scans revealed that 100% of patients without fixed defects had 3-year survival free of cardiac death versus 76% of patients who had fixed defects (p<0.001). Mild to moderate resting ischemia by qualitative interpretation of the scans was present in 20% of patients, but this did not predict outcome. Conclusions  Patients with spontaneous chest pain and nonischemic quantitative 99mTc sestamibi images were at reasonably low risk for hard cardiac events although some patients (18%) required revascularization. Supported in part by the DuPont Merck Pharmaceutical Company, N. Billerica, Mass.  相似文献   

13.

Background

Technetium 99m tetrofosmin is a new ethylene diphosphine ligand for myocardial perfusion imaging and has unique properties. We have compared stress-rest single-photon emission computed tomographic (SPECT) imaging with99mTc tetrofosmin with same-day and separate-day rest imaging to detect myocardial perfusion defects.

Methods and Results

Myocardial SPECT imaging was performed in 22 patients with coronary artery disease who had undergone planar thallium 201 imaging and coronary angiography. Single-day (stress-rest) and separate-day rest99mTc tetrofosmin SPECT protocols were compared in the same patient. Images were assessed by a blinded panel to identify myocardial infarction, ischemia, or normal scans. Overall sensitivity for identification of patients with coronary artery disease was 86% (19/22) by both same-day stress-rest and separate-day rest protocols with99mTc tetrofosmin (p=NS). Of a total of 396 segments studied, 107 abnormal segments were identified at exercise and 76 and 81 at the same-day and separate-day rest tests, respectively (p=NS). Same-day stress-rest and separate-day rest99mTc tetrofosmin SPECT protocols were also useful for detecting individual coronary stenosis with a greater than 50% lesion: 80% of the left anterior descending, 93% of the right coronary, and 75% of the left circumflex coronary arteries were detected.

Conclusion

Excellent images were obtained with99mTc tetrofosmin during both stress and rest.99mTc tetrofosmin imaging with the same-day stress-rest and separate-day rest imaging protocols have similar diagnostic sensitivities for detection of coronary heart disease.  相似文献   

14.

Background

The diagnostic accuracy of exercise 99mTc-labeled sestamibi and intravenous dipyridamole 201Tl-labeled myocardial tomography is established. The accuracy of dipyridamole stress 99mTc-labeled sestamibi myocardial tomography for the detection of coronary artery disease has not been reported.

Methods and Results

Our purpose was to determine the diagnostic accuracy of same-day, rest-dipyridamole stress 99mTc-labeled sestamibi myocardial single-photon emission computed tomography (SPECT) compared with coronary angiography. Two hundred forty-four patients who were unable to exercise adequately underwent both dipyridamole 99mTc-labeled sestamibi SPECT and coronary angiography within 6 months. Dipyridamole was administered intravenously in a standard dose of 0.56 mg/kg for 4 minutes. Cardiac and noncardiac side effects were recorded. The presence of coronary stenoses of 50% or greater diameter reduction in each of the major coronary arteries was compared with imaging data in corresponding myocardial perfusion beds. The patient population was predominately (98.8%) male with a mean age of 63±9 years (range 33 to 83 years). The majority of patients had stable angina (88%). Eighty-four patients (35%) gave a prior history of myocardial infarction; 44 patients (18%) had a history of congestire heart failure. The principal limitation to exercise stress was peripheral vascular disease in 62 patients (26%). No serious side effects occurred during dipyridamole stress; 14% of patients had chest pain and 8% of patients had 1 mm or greater ST segment depression. Of the 204 patients with documented coronary stenoses, 43 (21%) had single-vessel disease and 161 (79%) had multivessel disease. The sensitivity was 93% (40/43 in patients with single-vessel disease) and 91% (146/161 in patients with multivessel disease). Overall sensitivity was 91%. The specificity was 28% (11/40) in this population with a high prestest probability of coronary artery disease and posttest referral for cardiac catheterization.

Conclusion

99mTc-labeled sestamibi myocardial tomography in conjunction with intravenous dipyridamole stress is a safe and sensitive method for the detection of coronary artery disease. The diagnostic accuracy of dipyridamole stress 99mTc-labeled sestamibi SPECT for the detection of coronary artery disease is similar to that reported for exercise stress 99mTc-labeled sestamibi tomography, making this a suitable alternative for the evaluation of patients who are unable to exercise adequately.  相似文献   

15.
Single-photon emission tomography (SPET) using technetium-99m labelled myocardial tracers (e.g.99mTc-sestamibi) has become one of the most popular myocardial imaging methods for the diagnosis of coronary artery disease (CAD). This prospective study was designed to evaluate the diagnostic performance of99mTc-sestamibi exercise gated planar myocardial imaging by comparison with both visual and quantitative analyses of SPET. The study was conducted in 115 consecutive patients with known or suspected CAD, including 54 patients with a previous myocardial infarction (MI), referred for exercise testing prior to coronary angiography. Multi-gated planar imaging and SPET were performed after bicycle exercise. The end-diastolic (ED) and SPET images were visually scored (SVi). Myocardial uptake was quantitated on SPET slices using maximum count circumferential profiles (SQu) and defect extent was measured by comparison with gender-matched data sets obtained from 27 controls (<5% likelihood of CAD). CAD was defined as coronary artery stenosis >50% and/or regional wall motion abnormality. The cut-off criteria for positivity of the three procedures were determined from receiver operating characteristic (ROC) curves derived from the data of patients without previous MI. The area under the ROC curves was similar for ED, SVi and SQu. This was confirmed by the analysis of sensitivity performed using the ROC curve-derived cut-off criteria, in patients with or without previous MI. SVi was more sensitive than ED in identifying the diseased vessel(s) (ED: 41% vs SVi: 80%;P<0.0005) but ED was more specific in this respect (ED: 79% vs SVi: 61%;P<0.0005). We conclude that visual analysis of ED images obtained from gated99mTc-sestamibi stress planar imaging is a valuable alternative to SPET imaging for the diagnosis of CAD. SPET is, however, more accurate for the evaluation of the disease extent and localization and therefore remains the method of choice for the assessment of myocardial perfusion.  相似文献   

16.
BACKGROUND: Single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is routinely performed with patients' arms positioned above their heads to avoid potential attenuation artifact and reduced image quality. Currently no data are available to support the use of this practice using 99mTc SPECT MPI. METHODS AND RESULTS. Forty-one patients referred for routine rest/stress MPI were imaged using the standard protocol with arms positioned above their heads and again with their arms at their sides. The patients were injected with 10 to 45 mCi (370 to 1665 MBq) of 99mTc-labeled sestamibi (99mTc-sestamibi), and SPECT images were acquired 30 to 90 minutes later. Thirty patients were imaged on an ADAC Vertex dual-head camera and 11 patients on an ADAC Cirrus single-head camera. Images were interpreted by 3 nuclear cardiologists without knowledge of patient identity, arm position, or camera type using a 17-segment scoring model. No significant differences were noted in the percentage of abnormal study results, reversibility extent, or location of MPI defects between the 2 arm positions in the same patients. Image quality was also similar. CONCLUSION. Arm positioning does not influence the interpretation of 99mTc-sestamibi SPECT myocardial perfusion imaging with regard to image quality or defect location and extent.  相似文献   

17.
Background  The purpose of this study was to compare the incremental value of clinical information, electrocardiographic data, myocardial perfusion imaging, and radionuclide angiography for predicting severe coronary artery disease at a single testing interval. Clinical information, treadmill exercise studies, radionuclide angiography, and myocardial perfusion imaging are important predictors of severe coronary artery disease. However, the relative and absolute diagnostic importance of each of these methods has not been addressed at a single testing interval. Methods and Results  A same-day rest/treadmill exercise perfusion and function study was performed in 167 patients within 90 days of coronary angiography. A multivariable regression model was used to assess the independent informational content of these predictors. Clinical and electrocardiographic data were related strongly to the presence of severe coronary artery disease (χ2=12.2 and p<0.001; χ2=11.8 and p<0.001, respectively). Combined perfusion and functional studies contributed 31% of the diagnostic information beyond that provided by clinical and electrocardiographic data alone (p<0.05). Conclusions  These data demonstrate that combined studies of myocardial perfusion and left ventricular function are able to improve prediction of the extent of coronary artery disease, even when clinical and electrocardiographic data are also available. Presented in part at the Forty-Fifth Annual Scientific Sessions of the American College of Cardiology, Orlando, Fla., March 24–27, 1996.  相似文献   

18.
BACKGROUND: Myocardial perfusion imaging with dipyridamole is an alternative with which to evaluate patients who are unable to exercise. Many patients who undergo dipyridamole testing are limited in their ability, but are not completely unable, to exercise. There are benefits from adding low workload exercise to dipyridamole testing, including a reduction of thallium 201 concentration in the liver, leading to a higher heart-to-liver activity ratio and better image quality. This prospective study was designed to evaluate a protocol of exercise supplementation during dipyridamole technetium 99m sestamibi imaging and to verify whether a higher heart-to-liver activity ratio could be obtained. We also evaluated the potential of this combined protocol to prevent hypotension and induce ischemic changes on the electrocardiogram (ECG). METHODS AND RESULTS: Ninety consecutive patients who were not completely disabled for exercise underwent dipyridamole Tc-99m sestamibi cardiac single photon emission computed tomography with a protocol of exercise supplementation (DipEx). The heart-to-liver activity ratio, hemodynamics, and electrocardiographic changes were studied. The findings were compared with those of a control group (Dip) composed of 99 patients who underwent dipyridamole infusion alone. Patients with left bundle branch block, pacemaker, and atrial fibrillation were excluded. The DipEx patients tolerated the protocol, exercising 4.2 +/- 1.3 minutes on the treadmill (Bruce protocol). Compared with Dip, patients in the DipEx group had a higher heart-to-liver activity ratio (1.3 +/- 0.4 vs 1.6 +/- 0.5, respectively; P =.00001), had no incidence of hypotension (6% vs 0%, respectively; P =.03), and had a higher sensitivity of the ECG to detect ischemia (6% vs 34%, respectively; P =.003). The increase in sensitivity seen in the DipEx group was accompanied by a significant decrease in specificity compared with the Dip group (67% vs 100%, P =.000001). CONCLUSIONS: Our data show that the addition of limited exercise to dipyridamole results in benefits during Tc-99m sestamibi imaging, increasing heart-to-liver activity ratio, preventing vasodilator-induced hypotension, and improving ECG sensitivity for the detection of ischemia. Furthermore, this protocol also provides an estimation of the patient's physical capacity and could be used as an alternative for patients undergoing dipyridamole infusion who are not completely unable to exercise.  相似文献   

19.
Localization of Tc-99m sestamibi (MIBI) by parathyroid adenomas (PA) is well known. Typically the radionuclide washes out slowly from the PAs located in the neck. Rapid washout from some PAs has been reported. Various hypotheses have been postulated for slow and rapid clearance of MIBI from PAs, located in the neck. However, the washout of MIBI from ectopic parathyroid adenoma (EPA) in not well reported. We present a case of EPA with rapid washout of MIBI. Hence, early MIBI imaging plays an important role in the evaluation of EPA.  相似文献   

20.

Background

Serial perfusion imaging with 99mTc-labeled sestamibi has been useful in the assessment of myocardial salvage from reperfusion therapy during acute myocardial infarction. Studies in animal models have shown that discernible perfusion defects can be created by left ventricular asynergy from partial volume effects in the setting of homogenous perfusion tracer distribution. The purpose of this study was to examine the influence of gating on serial perfusion images during acute myocardial infarction to determine the magnitude of potential partial volume effects.

Methods and Results

99mTc-labeled sestamibi was injected into 18 patients during acute myocardial infarction and 29 patients 5 to 8 days after myocardial infarction. Tomographic imaging was acquired in gated format (16 frames per R-R cycle of the electrocardiogram) for each set of images. All frames were summed to produce ungated images. Tomographic images were quantified on three different thresholds to define the perfusion defect: 50%, 60%, and 70% of maximal counts. Severity of perfusion defects was calculated as the lowest ratio of minimum/maximum counts on five short-axis slices. Regional wall motion was assessed subjectively on the gated images by cine-loop display. Radionuclide ventriculography was performed at 6 weeks. There was a close correlation between perfusion defect size on ungated images and end-diastolic and end-systolic images independent of the quantitative threshold used (r=0.90 to 0.93; p<0.0001 for all correlations). Gated images provided consistently significantly greater estimates of perfusion defect size and severity by a small increment (3% to 9% of the left ventricle; p<0.05 for all comparisons) independently of the quantitative threshold used or the time of imaging (acute or late). Ungated images provided slightly better correlations with left ventricular ejection fraction at 6 weeks independently of the quantitative threshold used and despite significant wall motion abnormalities present on both the acute and final studies.

Conclusions

The differences between perfusion defect size for gated and ungated images were highly significant as a group, but the magnitude of difference was small and not clinically relevant. The larger estimates provided by end-diastolic gated images are opposite the difference expected if partial volume effects were significantly influencing perfusion defect size. Partial volume effects appear to have minimal impact on clinical tomographic imaging during acute myocardial infarction for the quantification of myocardium at risk and infarct size.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号