1.
The PFA-100 is a device that simulates high shear dependent platelet function in vitro and thus is particularly useful for screening for von Willebrand's disease (VWD). The aim of this study was to assess the overall potential of the PFA-100 as a primary clinical screening tool using the wide spectrum of clinical samples assessed for platelet function within our institution. The PFA-100 test was performed using both collagen/ADP (CADP) and collagen/epinephrine (CEPI) cartridges on samples from 337 patients with a wide variety of haemostatic defects. One hundred and eighty-two patients were defined as having normal platelet function based on classical laboratory tests and von Willebrand factor levels. The overall clinical sensitivity of the PFA-100 for platelet abnormalities (including VWD) was 81% for CADP and 86% for CEPI. The overall specificity was found to be 82% for CADP and 80% for CEPI. When utilizing both cartridges in combination (with both results either higher or lower than the upper cutoff of the normal ranges), the overall false positive and false negative rates were 12% and 6%, respectively. The PFA-100 proved to be sensitive in detecting classical defects by giving prolonged closure times in samples from patients with major platelet function defects (e.g. von Willebrand's disease, Glanzmann's thrombasthenia and Bernard Soulier syndrome). However, there were a small number of false negative results (6%) obtained with various milder platelet defects (e.g. Hermansky Pudlak syndrome, storage pool and release defects, type I VWD and macrothrombocytopenia). The PFA-100 test provides a useful rapid screening tool and should increase the efficiency and reduce the cost of the routine diagnosis of platelet dysfunction.  相似文献   

2.
《Platelets》2013,24(2):106-115
Monitoring of platelet ADP receptor P2Y12 inhibition may be performed by a variety of platelet function assays. Given the lack of sensitivity of the existing PFA-100® cartridge formulations to detect P2Y12 inhibition, a new cartridge for the PFA-100 (INNOVANCE® PFA P2Y) has recently been developed. The performance of the new PFA-100 test cartridge was compared with standard collagen/ADP (CADP) and collagen/epinephrine (CEPI) cartridges, light transmission aggregometry, vasodilator-stimulated phosphoprotein, the VerifyNow® P2Y12 assay and multiple electrode aggregometry. In this study, 20 normal blood samples anticoagulated with either citrate or hirudin were spiked with two different clinically relevant concentrations (1 and 10?µM final concentration) of the prasugrel active metabolite (R-138727, Lilly/Daiichi Sankyo) for 30?min at 37°C. Comparison of the platelet function tests demonstrated that all tests (except CADP and CEPI) were substantially inhibited by 10?µM R-138727. Intermediate results were typically obtained with 1?µM R-138727 in citrated blood. However, both MEA ADP and ADPHS tests were highly sensitive to 1?µM R-138727 in hirudin anticoagulated blood. Further comparison of citrate or hirudin blood samples (N?=?5) revealed that all platelet tests (except CEPI) became more sensitive to 1?µM R-138727 in hirudinized blood. The INNOVANCE PFA P2Y cartridge proved to be sensitive to P2Y12 inhibition and was comparable to other currently available platelet function tests. The sensitivity of all platelet function tests for detecting in vitro inhibition of P2Y12 is markedly different depending on the anticoagulant used.  相似文献   

3.
Summary.  There are no published reports investigating the ability of the platelet function analyzer (PFA‐100®) to detect the presence of delta‐granule platelet storage pool deficiencies (δ‐PSPD), a common mild bleeding disorder. Prior studies of the PFA‐100® and congenital platelet disorders have been limited by small numbers of patients with a variety of disorders. We examined PFA‐100® results in a large paediatric patient population diagnosed specifically with δ‐PSPD, and determined the relationship between PFA‐100® and platelet electron microscopy (the gold standard for diagnosis). This study is a retrospective review of patients <19 years of age diagnosed with δ‐PSPD at Nationwide Children’s Hospital from 2008 to 2010. To examine the correlation between PFA‐100® and average number of granules per platelet we used Spearman’s Rho as a non‐parametric measure of dependence. A total of 105 patients diagnosed with δ‐PSPD were included, of which 99 patients underwent PFA‐100® testing. Of those tested 46% had at least one abnormal closure time, whereas 16% had abnormal results for both cartridges. We found no statistical correlation between C‐EPI closure time and average number of granules per platelet (ρ= ?0.0095, P‐value = 0.9328), nor between C‐ADP closure time and the average number of granules (ρ = 0.0315, P‐value = 0.7798). The PFA‐100®, a widely used screening test for suspected bleeding disorders, did not correlate with presence or severity of δ‐PSPD as determined by platelet electron microscopy. When evaluating patients with suspected bleeding disorders, PFA‐100® alone cannot be used to rule out the presence of a δ‐PSPD.  相似文献   

4.
The bleeding time (BT) is widely used in clinical medicine as a screening test of platelet function, although its deficiencies in such a role are well recognized. The Platelet Function Analyzer (PFA)®-100 measures the ability of platelets activated in a high-shear environment to occlude an aperture in a membrane treated with collagen and epinephrine (CEPI) or collagen and ADP (CADP). The time taken for flow across the membrane to stop (closure time) is recorded. This study compared the PFA®-100 with the BT as a screening test of platelet dysfunction in 113 hospital inpatients. The PFA®-100 test was performed initially using the CEPI cartridge; CADP tests were performed on those with abnormal (> 163s) CEPI closure times. Whole blood platelet aggregation studies and chart review were performed on patients in whom the BT and PFA®-100 results did not agree. Abnormal bleeding times and PFA®-100 results were obtained in 20.4% and 35.4% of patients, respectively. The results of BT and PFA®-100 agreed in 74.3% of patients. Of the 29 patients in whom the BT and PFA®-100 results were discordant, whole blood platelet aggregation studies supported the PFA®-100 result in 25 (86.2%). The PFA®-100 was more sensitive to aspirin-induced platelet dysfunction and was more rapidly and cheaply performed than the BT. Since the PFA®-100 test reflects platelet function better than the BT, we conclude that this test could replace the BT as a first-line screening test for platelet dysfunction in clinical practice.  相似文献   

5.
Summary. While an estimated 13% of women with unexplained menorrhagia have von Willebrand disease (VWD), the frequency of other potential bleeding disorders has been uncertain. This study describes the relatively wide range of laboratory characteristics of women with unexplained menorrhagia and presents issues affecting diagnosis in this population. Women with pictorial blood assessment chart (PBAC) score >100 were identified at six U.S. sites and asked to remain drug free for 10 days prior to testing. Blood was collected on one of the first four menstrual cycle days and tested at a central laboratory for procoagulant factors, VWD and fibrinolytic factors. Platelet function testing by PFA‐100® (PFA) and platelet aggregation with ATP release (PAGG/ATPR) were performed locally using standardized methods. Among 232 subjects, a laboratory abnormality was found in 170 (73.3%), including 124 of 182 White (68.1%) and 34 of 37 Black (91.9%) subjects; 6.0% had VWD, 56.0% had abnormal PAGG/ATPR, 4.7% had a non‐VWD coagulation defect (NVCD) and 6.5% had an abnormal PFA only. AGG/ATPR was reduced in 58.9% of subjects, with multiple agonists in 28.6%, a single agonist in 6.1% and ristocetin alone in 24.2%. Frequencies of PAGG/ATPR defects varied by study site and race; frequencies of VWD and NVCD were similar. Laboratory abnormalities of haemostasis, especially platelet function defects, were common among women with unexplained menorrhagia across multiple U.S. sites. To what degree these abnormalities are clinically significant requires further study.  相似文献   

6.
Francis JL 《Platelets》2000,11(3):133-136
Whether patients with valvular heart disease have a defect of platelet function has been unclear. Despite evidence that these individuals have an abnormality detectable only under conditions of high shear stress, no methods have been widely available to adequately assess platelet function under such conditions. The Platelet Function Analyzer (PFA)-100 measures platelet function in a high shear environment and is well suited to the detection of platelet dysfunction in the clinical laboratory. The instrument records the time for platelets to occlude a membrane coated with collagen and either epinephrine (CEPI) or ADP (CADP). We studied the PFA-100 in 398 patients before open heart surgery; 308 for coronary artery bypass grafting (CABG) and 90 for aortic or mitral valve replacement (VR). Patients were classified as normal (CEPI < or = 153 s); 'aspirin effect' (CEPI > 153 s but CADP < or = 109 s) or abnormal (CEPI > 153 s and CADP > 109 s). In the CABG group, 41.2% were classified as normal, 43.2% as 'aspirin effect' and 15.6% as abnormal. In contrast, in patients undergoing VR, these values were 6.7, 11.1 and 82.4%, respectively. Patients with valvular disease had significantly longer closure times for both CEPI and CADP tests (P < 0.001). In addition, the valvular disease group had a significantly higher proportion of patients with markedly prolonged (> 150 s) closure times in the CADP cartridge (43.3 vs. 3.6%, respectively). Only one (0.3%) patient in the CABG group had non-closure (> 300 s) in the CADP test compared to seven (7.8%) in the valvular disease group. Three of six patients in the latter group bled excessively during surgery. We conclude that abnormal CADP closure is much more frequent among patients with aortic or mitral valve disease compared to those with coronary artery disease. This may reflect pre-existing high-shear damage to platelets that renders them refractory to subsequent shear activation and aggregation in the PFA-100 system. Further studies are needed to more precisely define the platelet defect in these patients. Markedly prolonged CADP closure in patients with valvular disease may indicate an increased likelihood of intra-operative bleeding, although an appropriately designed prospective study is needed to adequately address this hypothesis.  相似文献   

7.
Enhanced platelet activity correlates with early markers of myocardial damage in patients with cardiovascular disease. However, the extent to which enhanced platelet function signals subsequent adverse clinical outcomes in patients with cardiovascular disease is unknown. Blood from patients with stable cardiovascular disease receiving aspirin (325 mg/day) as the only antiplatelet therapy was tested for closure time (CT) with the Dade® PFA-100® Platelet Function Analyzer system collagen/adenosine diphosphate (ADP) [CADP] cartridge and platelet aggregometry using 10 µM ADP. This study intentionally focused on those patients defined as aspirin sensitive by previously established criteria of arachidonic acid- and ADP-induced platelet aggregometry, and separately by collagen/epinephrine (CEPI) CT using the PFA-100®. Follow up averaged 22 months for the adverse clinical events of death, myocardial infarction or cerebrovascular accident. For aspirin sensitivity determined by aggregometry, patients with CADP CT < 90 seconds (125/296 = 42.2%) had a composite endpoint rate of 19.2% (24/125), while those with CADP CT ≥90 seconds (171/296 = 57.8%) had an endpoint rate of 5.3% (9/171). Patients with CADP CT <90 seconds had a relative risk (RR) of 3.65 (95% CI.: 1.76–7.57) for recurrent events and 6.56 (95% CI.: 1.93–22.35) for death compared to patients with CADP CT ≥ 90s. Nearly identical results were obtained when patients were categorized as aspirin sensitive by CEPI CT. Platelet aggregometry with 10 µM ADP yielded no significant RR for the selected outcomes. Platelet function testing using the PFA-100® system appears to identify a subgroup of stable cardiovascular disease patients with increased risk of major adverse events that is associated with hypersensitivity to ADP, regardless of apparently effective aspirin therapy.  相似文献   

8.
Monitoring of platelet ADP receptor P2Y(12) inhibition may be performed by a variety of platelet function assays. Given the lack of sensitivity of the existing PFA-100? cartridge formulations to detect P2Y(12) inhibition, a new cartridge for the PFA-100 (INNOVANCE? PFA P2Y) has recently been developed. The performance of the new PFA-100 test cartridge was compared with standard collagen/ADP (CADP) and collagen/epinephrine (CEPI) cartridges, light transmission aggregometry, vasodilator-stimulated phosphoprotein, the VerifyNow? P2Y(12) assay and multiple electrode aggregometry. In this study, 20 normal blood samples anticoagulated with either citrate or hirudin were spiked with two different clinically relevant concentrations (1 and 10?μM final concentration) of the prasugrel active metabolite (R-138727, Lilly/Daiichi Sankyo) for 30?min at 37°C. Comparison of the platelet function tests demonstrated that all tests (except CADP and CEPI) were substantially inhibited by 10?μM R-138727. Intermediate results were typically obtained with 1?μM R-138727 in citrated blood. However, both MEA ADP and ADPHS tests were highly sensitive to 1?μM R-138727 in hirudin anticoagulated blood. Further comparison of citrate or hirudin blood samples (N?=?5) revealed that all platelet tests (except CEPI) became more sensitive to 1?μM R-138727 in hirudinized blood. The INNOVANCE PFA P2Y cartridge proved to be sensitive to P2Y(12) inhibition and was comparable to other currently available platelet function tests. The sensitivity of all platelet function tests for detecting in?vitro inhibition of P2Y(12) is markedly different depending on the anticoagulant used.  相似文献   

9.
Francis J  Francis D  Larson L  Helms E  Garcia M 《Platelets》1999,10(2-3):132-136
The bleeding time (BT) is widely used in clinical medicine as a screening test of platelet function, although its deficiencies in such a role are well recognized. The Platelet Function Analyzer (PFA)-100 measures the ability of platelets activated in a high-shear environment to occlude an aperture in a membrane treated with collagen and epinephrine (CEPI) or collagen and ADP (CADP). The time taken for flow across the membrane to stop (closure time) is recorded. This study compared the PFA-100 with the BT as a screening test of platelet dysfunction in 113 hospital inpatients. The PFA-100 test was performed initially using the CEPI cartridge; CADP tests were performed on those with abnormal (> 163 s) CEPI closure times. Whole blood platelet aggregation studies and chart review were performed on patients in whom the BT and PFA-100 results did not agree.Abnormal bleeding times and PFA-100 results were obtained in 20.4% and 35.4% of patients, respectively. The results of BT and PFA-100 agreed in 74.3% of patients. Of the 29 patients in whom the BT and PFA-100 results were discordant, whole blood platelet aggregation studies supported the PFA-100 result in 25 (86.2%). The PFA-100 was more sensitive to aspirin-induced platelet dysfunction and was more rapidly and cheaply performed than the BT. Since the PFA-100 test reflects platelet function better than the BT, we conclude that this test could replace the BT as a first-line screening test for platelet dysfunction in clinical practice.  相似文献   

10.
Summary. Therapy with factor VIII/von Willebrand factor (FVIII/VWF) concentrate is the mainstay therapy in patients with von Willebrand disease (VWD) unresponsive to desmopressin. There are several commercially available FVIII/VWF concentrates that have been tested in VWD patients. We retrospectively analized the clinical efficacy in bleeding episodes and surgery of a highly purified FVIII/VWF complex with two inactivation steps (Fanhdi®) in VWD patients. Sixty patients were included in the study. Treatment schedule consisted of one or more doses (standard dose 40 IU/kg body weight of FVIII) of Fanhdi®. One hundred and fifty bleeding episodes were treated. These were: 28 serious bleedings; 92 moderate and 30 mild. An excellent clinical efficacy in almost 95% of cases was observed. Fanhdi® was administered during 66 surgical procedures (38 major and 28 minor) with an overall efficacy of 98%. Fanhdi® a highly purified, doubly virus‐inactivated FVIII/VWF concentrate, with a high content of active VWF and an excellent record of clinical safety, is a valid choice in treating VWD.  相似文献   

11.
Treatment with exogenous von Willebrand factor (VWF) is indicated in patients with von Willebrand disease (VWD) in whom treatment with 1‐deamino‐8‐d ‐arginine vasopressin/desmopressin is contraindicated. Wilate® is a new generation plasma‐derived concentrate of native VWF and coagulation factor VIII (FVIII) (in a physiological 1:1 ratio) developed for the treatment of VWD. This is the first study to report safety, efficacy and in vivo recovery (IVR) data from 15 paediatric patients less than 6 years of age who received Wilate® for either prophylaxis, on‐demand treatment or for treatment in surgical procedures during a prospective open‐label trial (VWD type 1: 5, type 2A: 1, type 2B: 2, type 3: 6, unknown type: 1 patients). Analysis of IVR for VWF and FVIII suggested an appropriate and consistent rise in coagulation activity after Wilate® administration. Overall efficacy was rated as excellent or good for 99.7% [prophylactic infusions] and 100% [bleeding episodes/surgical procedures]. More than 82% of bleeding episodes resolved after 1 day of treatment, and a Wilate® dosage of 20–50 IU kg?1 was sufficient to achieve haemostasis in 97% of bleeding episodes. All surgical procedures were successfully managed with Wilate®. No thromboembolic events were observed during the study, and no patient developed anti‐VWF antibodies or FVIII inhibitors. In conclusion, this study confirms both the expected IVR profile in paediatric patients and the excellent efficacy, tolerability and safety profile of Wilate® observed previously in adults. Wilate® showed excellent efficacy in the treatment of bleeding when used prophylactically or on‐demand, and in the treatment of surgical procedures.  相似文献   

12.
The ristocetin cofactor assay (VWF:RCo) is the reference method for assessing von Willebrand factor (VWF) activity in the diagnosis of von Willebrand's Disease (VWD). However, the assay suffers from poor reproducibility and sensitivity at low levels of VWF and is labour intensive. We have undertaken an evaluation of a new immunoturbidimetric VWF activity (VWF:Ac) assay (INNOVANCE® VWF Ac. Siemens Healthcare Diagnostics, Marburg, Germany) relative to an established platelet‐based VWF:RCo method. Samples from 50 healthy normal subjects, 80 patients with VWD and 50 samples that exhibited ‘HIL’ (i.e. Haemolysis, Icterus or Lipaemia) were studied. VWF:Ac, VWF:RCo and VWF:Ag were performed on a CS–analyser (Sysmex UK Ltd, Milton Keynes, UK), all reagents were from Siemens Healthcare Diagnostics. The VWF:Ac assay, gave low intra‐ and inter‐assay imprecision (over a 31‐day period, = 200 replicate readings) using commercial normal (Mean 96.2 IU dL?1, CV < 3.0%) and pathological (Mean 36.1 IU dL?1, CV < 3.5%) control plasmas. The normal and clinical samples exhibited good correlation between VWF:RCo (range 3–753 IU dL?1) and VWF:Ac (rs = 0.97, < 0.0001), with a mean bias of 5.6 IU dL?1. Ratios of VWF:Ac and VWF:RCo to VWF:Ag in the VWD samples were comparable, although VWF:Ac had a superior lower level of detection to that of VWF:RCo (3% and 5% respectively). A subset (= 97) of VWD and HIL samples were analysed for VWF:Ac at two different dilutions to assess the effect on relative potency, no significant difference was observed (P = 0.111). The INNOVANCE® VWF Ac assay was shown to be reliable and precise.  相似文献   

13.
Ex vivo dipyridamole ‘non‐responsiveness’ has not been extensively studied in ischaemic cerebrovascular disease. Platelet surface marker expression, leucocyte‐platelet complex formation and inhibition of platelet function at high shear stress as detected by the PFA‐100® Collagen‐Adenosine‐diphosphate (C‐ADP) and Collagen‐Epinephrine cartridges was assessed in 52 patients within 4 weeks of transient ischaemic attack (TIA) or ischaemic stroke on aspirin, and then 14 d (14 d) and >90 d (90 d) after adding dipyridamole. A novel definition of ‘Dipyridamole non‐responsiveness’ was used. The median C‐ADP closure time increased following addition of dipyridamole, remained elevated at 90 d (P ≤ 0·03), and was unaffected by aspirin dose. 59% at 14 d and 56% at 90 d were ‘dipyridamole non‐responders’ on the PFA‐100. The proportion of non‐responders at 14 and 90 d was similar (P = 0·9). Compared with baseline (4·6%), median monocyte‐platelet complexes increased at 14 d (5·0%, P = 0·03) and 90 d (4·9%, P = 0·04). Low C‐ADP closure times were associated with increased monocyte‐platelet complexes at 14 d (r = ?0·32, P = 0·02) and 90 d (r = ?0·33, P = 0·02). Monocyte‐platelet complexes increased in the subgroup of dipyridamole non‐responders on the PFA‐100 (P ≤ 0·045), but not in responders (P ≥ 0·5), at 14 and 90 d versus baseline. Additional inhibition of platelet function has been detected with the PFA‐100 when dipyridamole is added to aspirin. Elevated monocyte‐platelet complexes may contribute to ex vivo dipyridamole non‐responsiveness.  相似文献   

14.
The relationships between the Platelet Function Analyzer (PFA)‐100 and von Willebrand factor (VWF) levels and bleeding score (BS) were evaluated within a multicentre project on Molecular and Clinical Markers for the Diagnosis and Management of type 1 von Willebrand disease (MCMDM‐1VWD). PFA‐100 closure time, either with epinephrine (EPI) or adenosine diphosphate (ADP)‐cartridges, was measured in 107 index cases, 105 affected and 71 unaffected family members, and 79 healthy controls. By regression analysis VWF levels were strongly related to both closure times, with a non‐linear progression. In a multiple stepwise regression model, age‐ and sex‐adjusted PFA‐100 ADP and VWF ristocetin cofactor activity (VWF:RCo) were independently associated with BS. Most of the variation of BS was predicted by PFA‐100 ADP and VWF:RCo alone. In the subgroup of patients with subtle abnormalities of the multimeric pattern, VWF was invariably reduced and closure time prolonged in almost all of them. Neither PFA‐100 ADP nor EPI closure times appeared to significantly improve the diagnostic capability of VWF antigen (VWF:Ag) measurement. Thus, in an unselected population a normal PFA‐100 would be useful to exclude VWD, but whether it could replace the more specific VWF assay in patients with significant mucocutaneous bleeding symptoms remains to be investigated prospectively.  相似文献   

15.
Summary. A predictive standardized bleeding questionnaire (Vicenza score), previously validated for identifying individuals with type 1 von Willebrand’s disease (VWD), has never been prospectively validated in tertiary care paediatric settings. The aim of this study was to assess the Vicenza score’s predictive power in identifying type 1 VWD, low von Willebrand factor (VWF) and platelet function defects (PFD) in a prospective cohort of patients, 0–17 years old, referred to a paediatric haematology clinic for evaluation of a bleeding disorder. Before the initial visit, caregivers consented to answer the questionnaire via telephone. Patients’ medical records were reviewed after haematological evaluation. VWF:Ag or VWF:RCo<30 IU dL?1 were labelled ‘definite type 1 VWD’ while 30–50 IU dL?1 were labelled ‘Low VWF’. PFA‐100 screening followed by abnormal electron microscopy and/or platelet aggregation studies diagnosed a PFD. At least one haemorrhagic symptom was present in 99 of the 104 children who completed the study (mean number of symptoms 2.87, mean Vicenza score 3.24). Eight met criteria for ‘definite type 1 VWD’, 23 for ‘low VWF’ and 13 for ‘PFD’. The sensitivity, specificity, and positive and negative predictive value (NPV) of the Vicenza score demonstrated poor diagnostic utility with the exception of high specificity in ruling out ‘definite type 1 VWD’. The NPV was comparably high with qualitative (>2 bleeding symptoms) and quantitative (Vicenza score ≥2) criteria. The Vicenza score has limited predictive value in paediatric tertiary care settings. While the NPV of excluding ‘definite type 1 VWD’ is high, simpler qualitative criteria is similarly predictive.  相似文献   

16.
Two hundred and five patients referred for evaluation of platelet functions and 126 healthy controls were tested with the PFA-100 instrument. A cut-off value of 150 s for collagen/epinephrine (CEPI) closure time (CT) produced most acceptable sensitivity (90%), specificity (85.2%), and positive (82.6%) and negative (91.6%) predictivity values for screening of platelet function disorders and von Willebrand disease (vWD). All patients with vWD and Glanzmann thrombasthenia could be detected by PFA-100. Both CEPI and collagen/adenosine diphosphate (CADP) CTs were elevated in all of these cases. Sensitivity of the device was 81.6% for patients with platelet secretion defects. CADP CT was normal in 63.9% of the patients in this subgroup. Specificity (47%) and positive predictivity (57%) of the instrument were diminished in patients with low hemoglobin concentrations. Depending on the results, an algorithm was developed for screening of platelet function disorders and vWD with PFA-100.  相似文献   

17.
Previous studies have shown that total platelet count (TPC) inadequately predicts bleeding in thrombocytopenic patients with haematological malignancies. This prospective cohort study evaluated whether rotational thromboelastometry (ROTEM), coagulation or other platelet parameters were more strongly associated with bleeding than TPC. Adults treated at two UK haematology centres for haematological malignancy were enrolled if they had thrombocytopenia (TPC ≤ 50 × 109/l) at beginning of, or during treatment (International Standard Randomized Controlled Trial Number 81226121). TPC and bleeding symptoms were recorded daily for up to 30 d or until platelet count recovery, hospital discharge or death. Blood samples were tested thrice weekly using ROTEM, Platelet Function Analyser (PFA)‐100®, coagulation and platelet cytometry assays. Bleeding symptoms and TPC from 49/50 enrolled participants who completed the study were recorded on 754/760 study days. Mean platelet volume and PFA‐100® closure times were frequently inestimatable because of thrombocytopenia. TPC, absolute immature platelet number (AIPN) and ROTEM maximum clot firmness were significantly associated with bleeding on the day after blood sampling. Only AIPN was associated with bleeding after adjustment of test results for TPC (Odds Ratio 0·52, 95% confidence interval 0·28–0·97; P = 0·038). In a predictive model, AIPN was superior to TPC for predicting bleeding. This study indicates that AIPN may be more clinically useful than TPC at predicting bleeding.  相似文献   

18.
The “platelet function analyzer” (PFA)?100 was first introduced to us in 1995. Since then, the instrument has appeared in over 50 reviews and almost 1000 publications. Recently, the PFA‐100 has been “upgraded” to the PFA‐200, which has transformed the user interface and electronic management, but retained the fundamental mechanics, and essentially provides the same results. The PFA‐100/200 has conceivable clinical utility to screen for von Willebrand Disease (VWD) and platelet disorders, and in monitoring desmopressin (DDAVP) therapy in both, and possibly anti‐platelet therapy. Its great strengths are its usage simplicity and sensitivity to conditions affecting primary hemostasis. However, as a “global” test, its limitation is that closure time (CT) test results are neither predictive of, nor specific for, any individual disorder. However, utilized properly, the PFA‐100/200 reflects a valuable addition to hemostasis laboratories involved in identification or therapeutic‐monitoring of disorders of primary hemostasis.  相似文献   

19.
The diagnosis of von Willebrand disease (VWD) is difficult due to the wide spectrum of clinical phenotypes associated with this disorder. We have analysed and characterized haemostatic function in VWD patients using a microchip‐based flow chamber system. Microchips coated with either collagen [platelet (PL)‐chip] or collagen/thromboplastin [atherome (AR)‐chip] were used to evaluate platelet thrombus formation at 1000 s?1 and fibrin‐rich platelet thrombus formation at 240 s?1 respectively. Blood samples from an asymptomatic patient with VWD type 1 [von Willebrand factor (VWF): RCo 3.2%; bleeding score (BS 2] displayed normal thrombus formation in both PL‐ and AR‐chips, whereas blood from a symptomatic type 1 patient (VWF: RCo 14%, BS 9) had significantly delayed capillary occlusion. Nearly complete suppression of the flow pressure increase was observed in symptomatic patients with VWD type 2A (BS 13) and 2N (BS 27), whereas no flow pressure was found for the type 3 patient (BS 6). Fibrin‐rich platelet thrombus formation was only weakly increased by the in vitro addition of factor VIII (FVIII) to blood samples from the type 3 patient, but was normalized by the addition of VWF/FVIII. The in vivo effects of treatment with desmopressin or VWF/FVIII for the symptomatic patients were analysed using two types of microchips. The PL‐chip was highly sensitive for patients’ VWF‐mediated platelet functions, whereas the AR‐chip allowed assessment of overall haemostatic ability, including sensitivity to both VWF and FVIII. The combined analysis with PL‐ and AR‐chips may be potentially useful for the diagnosis of VWD based on clinical phenotypes, and for monitoring drug effects.  相似文献   

20.
Data from case reports and systematic reviews suggest an association of Hypothyroidism and Acquired von Willebrand's syndrome. It is not known if congenital von Willebrand's disease is associated with hypothyroidism in a similar way. The aim of this study was to identify the association of congenital von Willebrand's disease (VWD) with clinical hypothyroidism. A total of 350 cases of congenital VWD were initially screened from our institution database from 1985 to 2010. A careful review of patient records was carried out to see if patients truly had congenital VWD and coexisting clinical hypothyroidism. Patients with uncertain diagnoses or other bleeding disorders were excluded, leading to 197 patients remaining in the final sample. A random age‐ and sex‐matched parallel control group was also obtained from the hospital database. Of 197 patients (mean age 43.8 ± 17.5 years, women 72%) of congenital VWD, 32/197 (16%) were diagnosed with clinical hypothyroidism, while only 11/197 (5.6%) of the matched controls were clinically hypothyroid. Univariate and multivariate analysis demonstrated that VWD was an independent predictor of developing clinical hypothyroidism (OR 3.45; 95% CI 1.65–7.22, P = 0.001). The proportion of patients diagnosed with clinical hypothyroidism was more in the VWD group (P < 0.0001). Our analysis shows a strong association of clinical hypothyroidism in patients with congenital VWD, but future studies will be required to delineate a pathological mechanism. In our opinion, clinicians should consider checking thyroid function in the newly diagnosed and established cases of congenital VWD.  相似文献   