首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In late 2001, some U.S. Postal Service workers and a few members of Congress were exposed to anthrax spores. This led to an increased effort to develop employable methods to protect workers from exposure to anthrax. Some investigations focused on selection and use of respirators to protect workers against airborne anthrax. The present study evaluated the potential for several types of half-mask respirators to release deposited particles. Four brands of the most commonly used filtering facepiece respirators (hereafter termed masks) were loaded with 0.59-μm, 1.0-μm, and 1.9-μm polystyrene latex (PSL) microspheres (nominally 0.6, 1.0, and 2.0 μm) and then dropped onto a rigid surface. The load conditions were 10, 20, or 40 million particles, and drop heights were 0.15, 0.76, and 1.37 m. For the average conditions of 0.76 m, 1.15 μm size and 22 million particles loaded, the average particle release was 0.604 particles per 10,000 (95% CI: .552, .662) particles loaded for all of the filtering facepieces tested. The averaging of conditions is a useful tool to provide generalized information and is also useful when making risk estimates. For most filtering facepiece respirators, particle release tended to increase with drop height and particle size, and there appeared to be a slight inverse relationship with particle load. Two brands of reusable elastomeric half-mask respirators with P100 high-efficiency particulate air (HEPA) filter cartridges were also evaluated. Results of these tests were inconclusive. Part II in this issue addresses the release of particles when simulating removal of a filtering facepiece from a wearer's head.  相似文献   

2.
Contact transmission of pathogens from personal protective equipment is a concern within the healthcare industry. During public health emergency outbreaks, resources become constrained and the reuse of personal protective equipment, such as N95 filtering facepiece respirators, may be needed. This study was designed to characterize the transfer of bacteriophage MS2 and fluorescein between filtering facepiece respirators and the wearer's hands during three simulated use scenarios. Filtering facepiece respirators were contaminated with MS2 and fluorescein in droplets or droplet nuclei. Thirteen test subjects performed filtering facepiece respirator use scenarios including improper doffing, proper doffing and reuse, and improper doffing and reuse. Fluorescein and MS2 contamination transfer were quantified. The average MS2 transfer from filtering facepiece respirators to the subjects' hands ranged from 7.6–15.4% and 2.2–2.7% for droplet and droplet nuclei derived contamination, respectively. Handling filtering facepiece respirators contaminated with droplets resulted in higher levels of MS2 transfer compared to droplet nuclei for all use scenarios (p = 0.007). MS2 transfer from droplet contaminated filtering facepiece respirators during improper doffing and reuse was greater than transfer during improper doffing (p = 0.008) and proper doffing and reuse (p = 0.042). Droplet contamination resulted in higher levels of fluorescein transfer compared to droplet nuclei contaminated filtering facepiece respirators for all use scenarios (p = 0.009). Fluorescein transfer was greater for improper doffing and reuse (p = 0.007) from droplet contaminated masks compared to droplet nuclei contaminated filtering facepiece respirators and for improper doffing and reuse when compared improper doffing (p = 0.017) and proper doffing and reuse (p = 0.018) for droplet contaminated filtering facepiece respirators. For droplet nuclei contaminated filtering facepiece respirators, the difference in MS2 and fluorescein transfer did not reach statistical significance when comparing any of the use scenarios. The findings suggest that the results of fluorescein and MS2 transfer were consistent and highly correlated across the conditions of study. The data supports CDC recommendations for using proper doffing techniques and discarding filtering facepiece respirators that are directly contaminated with secretions from a cough or sneeze.  相似文献   

3.
This study investigated the filtration performance of NIOSH-approved N95 and P100 filtering facepiece respirators (FFR) against six different monodisperse silver aerosol particles in the range of 4-30 nm diameter. A particle test system was developed and standardized for measuring the penetration of monodisperse silver particles. For respirator testing, five models of N95 and two models of P100 filtering facepiece respirators were challenged with monodisperse silver aerosol particles of 4, 8, 12, 16, 20, and 30 nm at 85 L/min flow rate and percentage penetrations were measured. Consistent with single-fiber filtration theory, N95 and P100 respirators challenged with silver monodisperse particles showed a decrease in percentage penetration with a decrease in particle diameter down to 4 nm. Penetrations less than 1 particle/30 min for 4-8 nm particles for one P100 respirator model, and 4-12 nm particles for the other P100 model, were observed. Experiments were also carried out with larger than 20 nm monodisperse NaCl particles using a TSI 3160 Fractional Efficiency Tester. NaCl aerosol penetration levels of 20 nm and 30 nm (overlapping sizes) particles were compared with silver aerosols of the same sizes by a three-way ANOVA analysis. A significant (p < 0.001) difference between NaCl and silver aerosol penetration levels was obtained after adjusting for particle sizes and manufacturers. A significant (p = 0.001) interaction with manufacturers indicated the difference in NaCl, and silver aerosol penetrations were not the same across manufacturers. The two aerosols had the same effect across 20 nm and 30 nm sizes as shown by the absence of any significant (p = 0.163) interaction with particle sizes. In the case of P100 FFRs, a significant (p < 0.001) difference between NaCl and silver aerosol (20 nm and 30 nm) penetrations was observed for both respirator models tested. The filtration data for 4-30 nm monodisperse particles supports previous studies that indicate NIOSH-approved air-purifying respirators provide expected levels of filtration protection against nanoparticles.  相似文献   

4.
The supply of N95 filtering facepiece respirators (FFRs) may not be adequate to match demand during a pandemic outbreak. One possible strategy to maintain supplies in healthcare settings is to extend FFR use for multiple patient encounters; however, contaminated FFRs may serve as a source for the airborne transmission of virus particles. In this study, reaerosolization of virus particles from contaminated FFRs was examined using bacteriophage MS2 as a surrogate for airborne pathogenic viruses. MS2 was applied to FFRs as droplets or droplet nuclei. A simulated cough (370 l min(-1) peak flow) provided reverse airflow through the contaminated FFR. The number and size of the reaerosolized particles were measured using gelatin filters and an Andersen Cascade Impactor (ACI). Two droplet nuclei challenges produced higher percentages of reaerosolized particles (0.21 and 0.08%) than a droplet challenge (<0.0001%). Overall, the ACI-determined size distribution of the reaerosolized particles was larger than the characterized loading virus aerosol. This study demonstrates that only a small percentage of viable MS2 viruses was reaerosolized from FFRs by reverse airflow under the conditions evaluated, suggesting that the risks of exposure due to reaerosolization associated with extended use can be considered negligible for most respiratory viruses. However, risk assessments should be updated as new viruses emerge and better workplace exposure data becomes available.  相似文献   

5.
A new system was used to determine the workplace protection factors (WPF) for dust and bioaerosols in agricultural environments. The field study was performed with a subject wearing an N95 filtering facepiece respirator while performing animal feeding, grain harvesting and unloading, and routine investigation of facilities. As expected, the geometric means (GM) of the WPFs increased with increasing particle size ranging from 21 for 0.7-1 microm particles to 270 for 5-10 microm particles (p < 0.001). The WPF for total culturable fungi (GM = 35) was significantly greater than for total culturable bacteria (GM = 9) (p = 0.01). Among the different microorganism groups, the WPFs of Cladosporium, culturable fungi, and total fungi were significantly correlated with the WPFs of particles of the same sizes. As compared with the WPFs for dust particles, the WPFs for bioaerosols were found more frequently below 10, which is a recommended assigned protection factor (APF) for N95 filtering facepiece respirators. More than 50% of the WPFs for microorganisms (mean aerodynamic diameter < 5 microm) were less than the proposed APF of 10. Even lower WPFs were calculated after correcting for dead space and lung deposition. Thus, the APF of 10 for N95 filtering facepiece respirators seems inadequate against microorganisms (mean aerodynamic size < 5 microm). These results provide useful pilot data to establish guidelines for respiratory protection against airborne dust and microorganisms on agricultural farms. The method is a promising tool for further epidemiological and intervention studies in agricultural and other similar occupational and nonoccupational environments.  相似文献   

6.
Background:During the Covid-19 outbreak, a recurrent subject in scientific literature has been brought back into discussion: whether surgical masks provide a sufficient protection against airborne SARS-CoV-2 infections.Objectives:The objective of this review is to summarize the available studies which have compared the respective effectiveness of surgical masks and filtering facepiece respirators for the prevention of infections caused by viruses that are transmitted by the respiratory tract.Methods:The relevant scientific literature was identified by querying the PubMed database with a combination of search strings. The narrower search string “(surgical mask *) AND (respirator OR respirators)” included all the relevant articles retrieved using broader search strategies. Of all the relevant articles found, seven systematic reviews were selected and examined.Results:The currently available scientific evidence seems to suggest that surgical masks and N95 respirators/FFP2 confer an equivalent degree of protection against airborne viral infections.Discussion:Since surgical masks are less expensive than N95 respirators but seem to be as effective in protecting against airborne infection and they are also more comfortable for the user, requiring less respiratory work, they should be the standard protective device for health care workers and especially for workers who carry out non-medical jobs. Filtering facepiece respirators, whose extended use is less comfortable for the wearer, may be preferred for procedures which require greater protection for a shorter time.Key words: Surgical masks, filtering facepiece respirators, aerosols, droplets, SARS-CoV-2, Covid-19  相似文献   

7.
NIOSH-certified N95 filtering facepiece respirators (FFRs) are used in healthcare settings as a control measure to mitigate exposures to airborne infectious particles. When the outer surface of an FFR becomes contaminated, it presents a contact transmission risk to the wearer. The Centers for Disease Control and Prevention (CDC) guidance recommends that healthcare workers (HCWs) doff FFRs by grasping the straps at the back of the head to avoid contact with the potentially contaminated surface. Adherence to proper doffing technique is reportedly low due to numerous factors including difficulty in locating and grasping the straps. This study compares the impact of tabs placed on FFR straps to controls (without tabs) on proper doffing, ease of use and comfort, and reduction of transfer of contamination to the wearer. Utilizing a fluorescent agent as a tracer to track contamination from FFRs to hand and head areas of 20 human subjects demonstrated that there was no difference in tabbed FFR straps and controls with respect to promoting proper doffing (p = 0.48), but did make doffing easier (p = 0.04) as indicated by 7 of 8 subjects that used the tabs. Seven of the 20 subjects felt that FFRs with tabs were easier to remove, while only 2 of 20 indicated that FFRs without tabs were easier to remove. Discomfort was not a factor for either FFR strap type. When removing an FFR with contaminated hands, the use of the tabs significantly reduced the amount of tracer transfer compared to straps without tabs (p = 0.012). FFRs with tabs on the straps are associated with ease of doffing and significantly less transfer of the fluorescent tracer.  相似文献   

8.
A preliminary study was undertaken to evaluate the potential for a disposable respirator that has been contaminated with anthrax spores to release spores in handling after use. The release of inert particles from disposable respirators was measured for masks dropped 3 feet onto a hard surface. Ten experimental runs were conducted for each of two N95 mask types, the Moldex 2200N95 and the 3M 8210. Anthrax spores were simulated with a test aerosol of single and double 1-micron polystyrene spheres. For the Moldex mask loaded with approximately 20 million spheres on it, an average of 0.16% was released; for the 3M mask an average of 0.29% was released.  相似文献   

9.
N95 particulate filtering facepiece respirators are certified by measuring penetration levels photometrically with a presumed severe case test method using charge neutralized NaCl aerosols at 85 L/min. However, penetration values obtained by photometric methods have not been compared with count-based methods using contemporary respirators composed of electrostatic filter media and challenged with both generated and ambient aerosols. To better understand the effects of key test parameters (e.g., particle charge, detection method), initial penetration levels for five N95 model filtering facepiece respirators were measured using NaCl aerosols with the aerosol challenge and test equipment employed in the NIOSH respirator certification method (photometric) and compared with an ultrafine condensation particle counter method (count based) for the same NaCl aerosols as well as for ambient room air particles. Penetrations using the NIOSH test method were several-fold less than the penetrations obtained by the ultrafine condensation particle counter for NaCl aerosols as well as for room particles indicating that penetration measurement based on particle counting offers a more difficult challenge than the photometric method, which lacks sensitivity for particles < 100 nm. All five N95 models showed the most penetrating particle size around 50 nm for room air particles with or without charge neutralization, and at 200 nm for singly charged NaCl monodisperse particles. Room air with fewer charged particles and an overwhelming number of neutral particles contributed to the most penetrating particle size in the 50 nm range, indicating that the charge state for the majority of test particles determines the MPPS. Data suggest that the NIOSH respirator certification protocol employing the photometric method may not be a more challenging aerosol test method. Filter penetrations can vary among workplaces with different particle size distributions, which suggests the need for the development of new or revised "more challenging" aerosol test methods for NIOSH certification of respirators.  相似文献   

10.
Protection of the human respiratory system from exposure to nanoparticles is becoming an emerging issue in occupational hygiene. The potential adverse health effects associated with particles of approximately 1-100 nm are probably greater than submicron or micron-sized particles. The performance of two models of N95 half-facepiece-filtering respirators against nano-sized particles was evaluated at two inhalation flow rates, 30 and 85 l min(-1), following a manikin-based protocol. The aerosol concentration was measured outside and inside the facepiece using the Wide-Range Particle Spectrometer. Sodium chloride particles, conventionally used to certify N-series respirators under NIOSH 42 CFR 84 regulations, were utilized as the challenge aerosol. The targeted particle sizes ranged from 10 to 600 nm, although the standard certification tests are performed with particles of approximately 300 nm, which is assumed to be the most penetrating size. The results indicate that the nanoparticle penetration through a face-sealed N95 respirator may be in excess of the 5% threshold, particularly at high respiratory flow rates. Thus, N95 respirators may not always provide the expected respiratory protection for workers. The highest penetration values representing the poorest respirator protection conditions were observed in the particle diameter range of approximately 30-70 nm. Based on the theoretical simulation, we have concluded that for respirators utilizing mechanical filters, the peak penetration indeed occurs at the particle diameter of approximately 300 nm; however, for pre-charged fiber filters, which are commonly used for N95 respirators, the peak shifts toward nano-sizes. This study has confirmed that the neutralization of particles is a crucial element in evaluating the efficiency of a respirator. The variability of the respirator's performance was determined for both models and both flow rates. The analysis revealed that the coefficient of variation of the penetration ranged from 0.10 to 0.54 for particles of 20-100 nm in diameter. The fraction of N95 respirators for which the performance test at 85 l min(-1) demonstrated excessive (>5%) penetration of nanoparticles was as high as 9/10. The test results obtained in a relatively small (0.096 m(3)) test chamber and in a large (24.3 m(3)) walk-in chamber were found essentially the same, thus, suggesting that laboratory-based evaluations have a good potential to adequately represent the respirator field performance.  相似文献   

11.
National Institute for Occupational Safety and Health recommends the use of particulate respirators for protection against nanoparticles (<100 nm size). Protection afforded by a filtering facepiece particulate respirator is a function of the filter efficiency and the leakage through the face-to-facepiece seal. The combination of particle penetration through filter media and particle leakage through face seal and any component interfaces is considered as total inward leakage (TIL). Although the mechanisms and extent of nanoparticle penetration through filter media have been well documented, information concerning nanoparticle leakage through face seal is lacking. A previous study in our laboratory measured filter penetration and TIL for specific size particles. The results showed higher filter penetration and TIL for 50 nm size particles, i.e. the most penetrating particle size (MPPS) than for 8 and 400 nm size particles. To better understand the significance of particle penetration through filter media and through face seal leakage, this study was expanded to measure filter penetration at sealed condition and TIL with artificially introduced leaks for 20-800 nm particles at 8-40 l minute volumes for four N95 models of filtering facepiece respirators (FFRs) using a breathing manikin. Results showed that the MPPS was ~45 nm for all four respirator models. Filter penetration for 45 nm size particles was significantly (P < 0.05) higher than the values for 400 nm size particles. A consistent increase in filter penetrations for 45 and 400 nm size particles was obtained with increasing breathing minute volumes. Artificial leakage of test aerosols (mode size ~75 nm) through increasing size holes near the sealing area of FFRs showed higher TIL values for 45 nm size particles at different minute volumes, indicating that the induced leakage allows the test aerosols, regardless of particle size, inside the FFR, while filter penetration determines the TIL for different size particles. TIL values obtained for 45 nm size particles were significantly (P < 0.05) higher than the values obtained for 400 nm size particles for all four models. Models with relatively small filter penetration values showed lower TIL values than the models with higher filter penetrations at smaller leak sizes indicating the dependence of TIL values on filter penetration. When the electrostatic charge was removed, the FFRs showed a shift in the MPPS to ~150 nm with the same test aerosols (mode size ~75 nm) at different hole sizes and breathing minute volumes, confirming the interaction between filter penetration and face seal leakage processes. The shift in the MPPS from 45 to 150 nm for the charge removed filters indicates that mechanical filters may perform better against nanoparticles than electrostatic filters rated for the same filter efficiency. The results suggest that among the different size particles that enter inside the N95 respirators, relatively high concentration of the MPPS particles in the breathing zone of respirators can be expected in workplaces with high concentration of nanoparticles. Overall, the data obtained in the study suggest that good fitting respirators with lower filter penetration values would provide better protection against nanoparticles.  相似文献   

12.
Fit factor is the ratio of the particle concentration outside (C(out)) to the inside (C(in)) of the respirator and assumes that filter penetration is negligible. For Class-95 respirators, concerns were raised that filter penetration could bias fit test measurements. The TSI N95-Companion was designed to overcome this limitation by measuring only 40-60 nm size particles. Recent research has shown that particles in this size range are the most penetrating for respirators containing electrostic filter media. The goal of this study was to better understand the performance of the N95-Companion by assessing the impact of filter penetration and by comparing C(out)/C(in) ratios measured by other aerosol instruments (nano-Differential Mobility Analyzer/Ultrafine Condensation Particle Counter (nano-DMA/UCPC) and the TSI PortaCount Plus) using N95 filtering facepiece respirators sealed to a manikin and with intentionally created leaks. Results confirmed that 40-60 nm-diameter size room air particles were most penetrating for the respirators tested. A nonlinear relationship was found between the N95-Companion-measured C(out)/C(in) ratios and the other instruments at the sealed condition and at the small leak sizes because the N95-Companion measures only charged particles that are preferentially captured by the electrostic filter media, while the other instrument configurations also measure uncharged particles, which are captured less efficiently. The C(out)/C(in) ratios from the N95-Companion for experiments conducted under sealed condition suggest that filter penetration of negatively charged 40-60 nm size particles was less than 0.05%. Thus, the N95-Companion measured C(out)/C(in) ratios are due primarily to particle penetration through leakage, not through filter media, while the C(out)/C(in) ratios for the PortaCount, nano-DMA/UCPC, and UCPC result from a combination of face seal leakage and filter penetration.  相似文献   

13.
A method for performing quantitative fit tests (QNFT) with N95 filtering facepiece respirators was developed by earlier investigators. The method employs a simple clamping device to allow the penetration of submicron aerosols through N95 filter media to be measured. The measured value is subtracted from total penetration, with the assumption that the remaining penetration represents faceseal leakage. The developers have used the clamp to assess respirator performance. This study evaluated the clamp's ability to measure filter penetration and determine fit factors. In Phase 1, subjects were quantitatively fit-tested with elastomeric half-facepiece respirators using both generated and ambient aerosols. QNFT were done with each aerosol with both P100 and N95 filters without disturbing the facepiece. In Phase 2 of the study elastomeric half facepieces were sealed to subjects' faces to eliminate faceseal leakage. Ambient aerosol QNFT were performed with P100 and N95 filters without disturbing the facepiece. In both phases the clamp was used to measure N95 filter penetration, which was then subtracted from total penetration for the N95 QNFT. It was hypothesized that N95 fit factors corrected for filter penetration would equal the P100 fit factors. Mean corrected N95 fit factors were significantly different from the P100 fit factors in each phase of the study. In addition, there was essentially no correlation between corrected N95 fit factors and P100 fit factors. It was concluded that the clamp method should not be used to fit-test N95 filtering facepieces or otherwise assess respirator performance.  相似文献   

14.
This article presents a computational and experimental study of contact pressure between six N95 filtering facepiece respirators (FFRs) and five newly developed digital headforms (small, medium, large, long/narrow, and short/wide). Contact interaction is simulated using the finite element method and validated by experiments using a pressure mapping system. The headform model has multiple layers: a skin layer, muscle layer, fatty tissue layer, and bone layer. Each headform is divided into five parts (two parts for the cheeks, one part for the upper forehead, one part for the chin, and one part for the back side of the head). Each respirator model comprises multiple layers and two straps. The simulation process has two stages for each respirator/headform combination. The first stage is to wrap the straps around the back of the headform and pull the respirator away from the face. The second stage is to release the respirator so that the respirator moves toward the face. Strap forces and contact interactions are generated between the respirators and the headforms. Meanwhile, a real-time surface pressure mapping system is used to record the pressures at six key locations to validate the computational results. There is a strong correlation between computational and experimental results (R(2) = 0.88). By comparing the pressure values from simulations and experiments, we have validated the simulation models.  相似文献   

15.
The performance of three filtering facepiece respirators (two models of N99 and one N95) challenged with an inert aerosol (NaCl) and three virus aerosols (enterobacteriophages MS2 and T4 and Bacillus subtilis phage)-all with significant ultrafine components-was examined using a manikin-based protocol with respirators sealed on manikins. Three inhalation flow rates, 30, 85, and 150 l min(-1), were tested. The filter penetration and the quality factor were determined. Between-respirator and within-respirator comparisons of penetration values were performed. At the most penetrating particle size (MPPS), >3% of MS2 virions penetrated through filters of both N99 models at an inhalation flow rate of 85 l min(-1). Inhalation airflow had a significant effect upon particle penetration through the tested respirator filters. The filter quality factor was found suitable for making relative performance comparisons. The MPPS for challenge aerosols was <0.1 mum in electrical mobility diameter for all tested respirators. Mean particle penetration (by count) was significantly increased when the size fraction of <0.1 mum was included as compared to particles >0.1 mum. The filtration performance of the N95 respirator approached that of the two models of N99 over the range of particle sizes tested ( approximately 0.02 to 0.5 mum). Filter penetration of the tested biological aerosols did not exceed that of inert NaCl aerosol. The results suggest that inert NaCl aerosols may generally be appropriate for modeling filter penetration of similarly sized virions.  相似文献   

16.
We evaluated correctness of N95 filtering facepiece respirator donning by the public in post-hurricane New Orleans, where respirators were recommended for mold remediation. We randomly selected, interviewed, and observed 538 participants, using multiple logistic regression for analysis. Only 129 (24%) participants demonstrated proper donning. Errors included nose clip not tightened (71%) and straps incorrectly placed (52%); 22% put on the respirator upside down. Factors independently associated with proper donning were as follows: ever having used a mask or respirator (odds ratio [OR] 5.28; 95% confidence interval [CI], 1.79-22.64); ever having had a respirator fit test (OR 4.40; 95% CI, 2.52-7.81); being male (OR 2.44; 95% CI, 1.50-4.03); Caucasian race (OR 2.09; 95% CI, 1.32-3.33); having a certified respirator (OR 1.99, 95% CI, 1.20-3.28); and having participated in mold clean-up (OR 1.82; 95% CI,1.00-3.41). Interventions to improve respirator donning should be considered in planning for influenza epidemics and disasters.  相似文献   

17.
OBJECTIVES: We have recently developed a new personal sampling system for the real-time measurement of the protection provided by respirators against airborne dust and micro-organisms. The objective of this study was to evaluate the performance characteristics of the new sampling system in both laboratory and field conditions. METHODS: The measurements were conducted using the N95 filtering facepiece respirators and the newly developed personal sampling system put on a manikin (laboratory study) or donned by a human subject (laboratory and field studies). Two inhalation flow rates (0 and 40 l min(-1)) in conjunction with the sampling flow rate (10 l min(-1)) were tested in the manikin-based experiments to investigate the effects of the leak location (nose, cheek and chin) and the depth of the sampling probe (0, 5, 10 and 15 mm) within the respirator. The effect of human activity on the protection factor was evaluated using a variety of head movements and breathing patterns when a human subject wore the respirator in a room-size laboratory test chamber. The field study was conducted during corn harvesting with a respirator worn by a human subject on a combine. RESULTS: There was no significant difference in the protection factors for different leak locations, or for sampling probe depths, when the inhalation rate was 0 l min(-1). For the inhalation rate of 40 l min(-1), the protection factors for nose leaks were higher than those for chin and cheek leaks. Furthermore, the protection factor was the lowest and showed the least variation when the sampling probe depth was equal to 0 mm (imbedded on the respirator surface). Human subject testing showed that the grimace maneuver decreased the protection factor and changed the original respirator fit. The protection factor during breath holding was lower than that found during inhalation and exhalation. Field results showed greater variation than laboratory results. CONCLUSIONS: The newly designed personal sampling system efficiently detected the changes in protection factors in real time. The sampling flow was least affected by the inhalation flow when the sampling probe was imbedded on the respirator surface. Leak location, breathing patterns and exercises did affect the measurement of the protection factors obtained using an N95 filtering facepiece respirator. This can be attributed to the differences in the in-mask airflow dynamics contributed by the leak, filter material, sampling probe and inhalation. In future studies, it would be beneficial if the laboratory data could be integrated with the field database.  相似文献   

18.
Protection factors were measured on full face mask power assisted respirators when worn by experienced asbestos removal operatives under simulated asbestos removal work conditions. The sulfur hexafluoride test method as defined in European Standards was employed to determine the leakage into the respirators. Protection factors were measured on a total of 21 test volunteers. The test method allowed protection factors to be related to wearer activities and practices. Poor fitting techniques and simulated reduction in the respirator's performance resulted in a reduction in the protection factor. Visual inspection of the RPE usually worn by the volunteers identified inadequate maintenance. This study re-emphasises that careful selection, facepiece fit testing and correct use and maintenance of RPE are essential to ensure optimum protection to the wearer.  相似文献   

19.
The effects of intermittently loading small masses of sodium chloride aerosol on the filtration efficiency of N-95 filtering facepiece respirators was investigated. The National Institute for Occupational Safety and Health (NIOSH) certifies that N-95 respirators must provide at least 95 percent filtration efficiency against a sodium chloride aerosol challenge as per the respirator certification (42 CFR 84) test criteria. N-95 respirators are specified for protection against solid and water-based particulates (i.e., non-oil aerosols). New N-95 respirators from three different manufacturers were loaded with 5 +/- 1 mg of sodium chloride aerosol one day a week, over a period of weeks. Aerosol loading and penetration measurements were performed using the TSI 8130 Filter Tester. Respirators were stored uncovered on an office desktop outside the laboratory. To investigate environmental and temporal effects of filters being stored without sodium chloride exposure, control respirators were stored on the desk for various lengths of time before being initiated into weekly testing. For all manufacturers' respirators, the controls showed similar initial penetrations on their day of initiation (day zero) to those of the study samples on day zero. As the controls were tested weekly, they showed similar degradation rates to those of the study samples. Results show that some of the manufacturers' models had penetrations of greater than 5 percent when intermittently exposed to sodium chloride aerosol. It is concluded that intermittent, low-level sodium chloride aerosol loading of N-95 respirators has a degrading effect on filter efficiency. This reduction in filter efficiency was not accompanied by a significant increase in breathing resistance that would signal the user that the filter needs to be replaced. Furthermore, it was noted that the effect of room storage time prior to initial exposure was much less significant.  相似文献   

20.
This study evaluated the workplace performance of an N95 filtering facepiece, air-purifying respirator in a steel foundry. Air samples were collected inside and outside respirators worn by workers who were properly trained and qualitatively fit tested. For most workers, three or four pairs of air samples were collected on each of 2 days. The 49 valid sample sets were analyzed for iron, silicon, and zirconium. Only iron was present in sufficient concentrations to perform workplace protection factor (WPF) calculations. Individual WPF measurements ranged from 5 to 753. The geometric mean of the distribution was 119 with a lower 5th percentile value of 19. Time-weighted average WPFs (WPF(TWA)) were also calculated for each day for each worker as an estimate of the protection an individual might receive with daily respirator use. The WPF(TWA) values ranged from 15 for the worker with the single WPF value of 5, to a high of 684. The distribution of WPF(TWA) had a geometric mean of 120 and a lower 5th percentile of 22. Both data treatments indicate this respirator's performance was consistent with the assigned protection factor of 10 typically used for half facepiece respirators. The respirator provided adequate protection as used in this study. All contaminant concentrations inside the respirator were well below the relevant occupational exposure limits. Data collected also illustrate the dynamic nature of faceseal leakage in the workplace.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号