首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

The use of porous tantalum for the acetabular component in primary total hip arthroplasty (THA) has demonstrated excellent short-term and midterm results. However, long-term data are scarce. The purpose of this prospective study is to report the long-term clinical and radiologic outcome following use of an uncemented porous tantalum acetabular component in primary THA with a minimum follow-up of 17.5 years, in a previously studied cohort of patients.

Methods

We prospectively followed 128 consecutive primary THAs in 140 patients, between November 1997 and June 1999. A press-fit porous tantalum monoblock acetabular component was used in all cases. All patients were followed clinically and radiographically for a mean of 18.1 years (range, 17.5-19 years).

Results

Mean age of patients at the time of operation was 60.4 years. Harris hip score, Oxford hip score, and range of motion were dramatically improved in all cases (P < .001). At last follow-up, all cups were radiographically stable with no evidence of migration, gross polyethylene wear, progressive radiolucencies, osteolytic lesions, or acetabular fractures. The survivorship with reoperation for any reason as end point was 92.8% and the survivorship for aseptic loosening as an end point was 100%.

Conclusion

The porous tantalum monoblock cup in primary THA demonstrated excellent clinical and radiographic outcomes with no failures because of aseptic loosening at a mean follow-up of 18.1 years.  相似文献   

2.
《The Journal of arthroplasty》2020,35(10):2931-2937
BackgroundIt is proposed that highly porous coatings on acetabular components, such as a porous tantalum coating, provide adequate fixation without ancillary screw fixation in primary total hip arthroplasty (THA). However, tantalum acetabular components have been associated with higher rates of revision than other uncemented components in national registries. The aim of this randomized controlled trial is to determine whether the early migration of a solid-backed tantalum acetabular component was no greater than that of a titanium acetabular component with ancillary screw fixation that has proven good clinical results.MethodsSixty-six patients aged 40 to 64 years, with osteoarthritis and Charnley grade A or B activity grade and who underwent primary THA, were recruited into the trial. Patients were randomized intraoperatively to receive either the tantalum or titanium acetabular component. All patients received the same cemented polished tapered femoral stem, 28-mm cobalt-chromium femoral head, and highly cross-linked polyethylene liner. Acetabular component migration was measured using radiostereometric analysis at 4-6 days postoperatively and at 6 weeks, 3 months, 1 and 2 years following THA.ResultsThe mean proximal migration at 2 years for the tantalum cohort was 0.17 mm (95% confidence interval, 0.09-0.24) which was no greater than that of the titanium cohort which was 0.19 mm (0.07-0.32). Harris hip scores and functional activity scores were similar between groups.ConclusionThese results demonstrate that early stability can be achieved without ancillary screw fixation through the use of a highly porous high friction coating on a solid-backed modular acetabular component.Level of EvidenceLevel I.  相似文献   

3.

Background

With the introduction of new fixation systems and designs, there has been a recent reemergence of interest in cementless fixation of the tibial component in total knee arthroplasty. However, little is known regarding the clinical features and survivorship of the cementless porous tantalum monoblock tibial component compared to the conventional cemented modular tibial component.

Methods

We conducted a literature search of multiple databases for comparative studies published before June 2015 that investigated the outcomes of cementless porous tantalum monoblock tibia vs conventional cemented modular tibia. A pooled analysis was performed. The outcomes of interest were postoperative functional score, range of motion, Western Ontario and McMaster University Osteoarthritis Index, total complications, reoperation, radiolucent lines, loosening of the tibial component, and length of operation.

Results

Six studies involving 977 patients were eligible for the meta-analysis. The use of a cementless porous tantalum monoblock tibial component may associate with a slightly higher functional score, fewer radiolucent lines, and shorter operation. No significant difference was seen in regard to the range of motion, Western Ontario and McMaster University Osteoarthritis Index, total complications, reoperation, and loosening of the component between the 2 groups.

Conclusion

However, due to variation among the included studies, the use of cementless porous tantalum monoblock tibia seems to achieve no substantial superiority over that of the conventional cemented modular tibia at 5-year follow-up. Data concerning the long-term prognosis of this novel implant should continue to be collected and analyzed.  相似文献   

4.

Background  

First-generation modular titanium fiber-metal-coated acetabular components had high rates of wear, pelvic osteolysis, and liner dissociation. Second-generation components were designed to reduce the incidence of these problems but it is unclear whether the changes achieved these goals.  相似文献   

5.

Background  

During the mid-1990s when our institution was using a press-fit porous-coated cup without supplemental initial fixation for primary THA, the manufacturer transitioned from gamma irradiation to gas plasma for the terminal sterilization of their polyethylene liners.  相似文献   

6.
《The Journal of arthroplasty》2021,36(10):3507-3512
BackgroundCeramic-on-ceramic bearings are becoming increasingly popular in primary total hip arthroplasty (THA). To enhance ceramic-on-ceramic liner exchange in case of revision surgery, metal-backed liner systems have been proposed. Little is known about the clinical performance of these implants. The purpose of this study is to evaluate a metal-backed liner implant system for primary THA.MethodsA total of 422 patients (with 468 consecutive THAs) were followed over a mean period of 10 years. All arthroplasties were performed with a cementless stem, a press-fit cup, and a metal-backed liner system. Surgical and clinical data, complications, and revisions were analyzed. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) before surgery and at 1 and 10 years after surgery were compared.ResultsThe overall 10-year implant survival rate was 93.8%. The survival rate was 97.0% for heads and liners, 97.5% for stem, and 99.3% for acetabular cup. The most common reason for revision was ceramic breakage (2.4%) of the third-generation (BIOLOX forte) acetabular liner. Mean WOMAC score improved significantly from 50.1 before surgery to 13.2 at 1 year after surgery. There was no difference in WOMAC scores between surgical approach and type of bearing at 1 and 10 years after surgery.ConclusionTHA using cementless stem, press-fit cup, and metal-backed liner system provides satisfactory long-term outcomes, with revision rate comparable to that with other systems available in the market. The metal-backed liner system has low risk of mal-seating. Third-generation ceramic liners should be avoided as they seem to be more prone to breakage.  相似文献   

7.
A significant rim defect encountered during revision surgery can make stable cementless cup fixation difficult. One approach to this problem is to medialize the acetabular cup to improve the degree of rim contact. In this study, we investigate this technique, termed the medial protrusio technique, for acetabular fixation in revision hip arthroplasty. A retrospective review of 25 patients (25 hips) who underwent medialization was performed. Clinical and radiographic evaluation was performed. At an average follow-up of 6.6 years, the overall patient function and satisfaction were good to excellent, with a mean Harris hip score of 85.2. This demonstrates that the medial protrusio technique can be a valuable option in addressing acetabular cup failure.  相似文献   

8.
We reviewed 263 consecutive patients with failed acetabular components after total hip arthroplasty that were revised using porous tantalum acetabular components and augments when necessary. The mean follow-up was 73.6 months (range, 60-84 months). The improvement of mean Harris hip score, Western Ontario and McMaster Osteoarthritis Index, and University of California Los Angeles activity scales were statistically significant (P < .001). Subjective assessments showed that 87.3% of patients reported “improvement” and 85.9% were “very or fairly pleased” with the results. At the most recent follow-up, all acetabular components were radiographically stable and none required rerevision for loosening. The acetabular revision was considered successful in 87% of cases. From this study, we conclude that the acetabular component used was reliable in creating a durable composite without failure for a minimum of 5 years.  相似文献   

9.
目的 探讨髋臼骨折CT扫描的分型及其临床意义。方法 对 6 4例髋臼骨折的病例进行回顾性分析 ,总结其创伤机理、形态学共性和X线片、CT扫描的影像学资料 ,结合治疗方法以及预后评价进行分型。结果 髋臼CT扫描的临床分型分为简单骨折和复合骨折两个大类 6个基本类型。结论 特别提出了髋臼顶部骨折型和髋臼内有游离骨块型 ,并逐型进行了讨论以说明该分型具有积极的临床指导意义  相似文献   

10.
BackgroundPeriprosthetic osteolysis is a serious complication following total hip arthroplasty (THA). However, most orthopedic surgeons only focus on bone loss and hip reconstruction. Thus, it was required to understand the treatment algorithm for periprosthetic osteolysis integrally.Case PresentationA 52‐year‐old Asian male presented with chronic hip pain. A mass appeared on the medial side of the proximal left thigh at more than 20 years after bilateral THA. Radiographs revealed catastrophic periprosthetic osteolysis, especially on the acetabular side. Large amounts of necrotic tissue and bloody fluids were thoroughly debrided during revision THA. A modular hemipelvic prosthesis was used for revision of the left hip. Four years later, the patient presented with right hip pain, where a mass appeared on the medial side of the proximal right thigh. A primary acetabular implant with augment was used for revision of the right hip. Laboratory evaluation of bloody fluid retrieved from surgery revealed elevated levels of inflammatory markers.ConclusionInflammatory responses to polyethylene wear debris can lead to severe bone resorption and aseptic loosening in the long‐term following THA. Therefore, in spite of revision THA, interrupting the cascade inflammatory might be the treatment principle for periprosthetic osteolysis.  相似文献   

11.
12.
《The Journal of arthroplasty》2020,35(8):2090-2096
BackgroundThe type of total knee arthroplasty (TKA) fixation (cemented or uncemented) is still subject to debate. The aim of this study is to assess the survival rate, clinical outcomes, and radiological results of TKA according to the fixation type.MethodsA total of 130 patients were randomly assigned to either the cement group (cemented femoral and tibial implants) or the hybrid group (cemented tibial implant, uncemented femoral implant). The inclusion criteria were patients between 50 and 90 years old who underwent primary TKA for osteoarthritis between 2004 and 2005 without a history of open knee surgery. Revisions and complications were reported, as well as clinical scores and radiological signs of loosening.ResultsOne hundred eighteen patients had complete data at 10 years of minimum follow-up (59 in each group). The mean age was 72 years old. The mean follow-up was 13 years. The survival rate was 98% at 13 years in both groups (1 aseptic loosening at 2 years in the cement group, 1 septic loosening in the hybrid group). The complication rate in the cement group was 8.5% (n = 5) vs 12.1% (n = 7) in the hybrid group (P = .8). The clinical results were not significantly different. In the cement group, 25% of patients (n = 15) had radiolucent lines at 10 years. In the hybrid group, 33% of patients had bone transparencies, not evolving or symptomatic.ConclusionAt a minimum follow-up of 10 years, there were no significant differences between cemented TKA and hybrid TKA for the survivorship, the complication rate, the clinical scores, or the radiological signs of loosening.Level of EvidenceI.  相似文献   

13.
Polyethylene wear-induced osteolysis constitutes the most severe long-term complication of total hip arthroplasties (THA). Our aim was to assess through MRI the severity and growth pattern of osteolysis, as well as the influence clinical-radiographic variables exert. We analyzed 75 THA with an average evolution time of 13.67 years. The implant was a titanium alloy, non-cemented, multiple-hole model with hydroxyapatite coating. Osteolysis was found with a peripheral pattern in 48 and a central pattern in 6; in 52 cases it was continuous, and in 4, isolated. Out of 118 screws, 20 exhibited lysis. There was a proportional correlation between osteolysis severity and wear rate with age, physical activity and acetabular abduction, as well as an association between said variables and peripheral and continuous patterns.  相似文献   

14.

Background

This study aims at determining the average long-term result of revision total hip arthroplasty (THA) using the acetabular reinforcement ring with a hook (ARRH) and bone grafting in severe acetabular bony defect. Expected 15-year survival of ARRH in revision THA is included in the study.

Methods

Retrospective review of 48 patients (48 hips) with follow-up duration of average 11.4 years (range, 6.1-21.4 years) was conducted. At each follow-up, Harris hip score was used to assess functional outcome, and radiographic acetabular component osteolysis was measured by DeLee and Charnley classification. Bone defects were assessed preoperatively and intraoperatively using American academy of orthopedic surgeons and Paprosky classification. The common modes of ARRH failures were evaluated. Bone consolidation, presence of heterotopic ossification, and complications such as infection and dislocation were recorded.

Results

The bone defects were varied and included cavitary, segmental, and combined defects without any pelvic discontinuity. Mean Harris hip score improved from 52.6 points preoperatively to 82.0 points postoperatively. Nine acetabular revisions and 3 stem revisions (2 concurrent with acetabular revisions and 1 isolated stem revision) were performed. There were 5 infected cases and 1 patient with recurrent dislocation. The 11.4-year survival of revision THA with ARRH was 71% as the end point for acetabular revision surgery for any reason. The expected 15-year survival of revision THA with ARRH was 60%. The most common failure mode of ARRH was superomedial migration followed by lateral migration.

Conclusion

ARRH combined with bone grafting produces relatively good average long-term clinical results.  相似文献   

15.

Background

Advancements in the management of human immunodeficiency virus (HIV) now permit HIV-positive patients to have longer life spans, increasing their cumulative risk of developing an advanced degenerative joint disease, necessitating total hip arthroplasty (THA). The purpose of this study was to provide an extended follow-up on a previously published study on a cohort of HIV-positive THA recipients in an effort to confirm the safety and longevity of THA in this population.

Methods

This study is a follow-up on a previous study comprised of 41 hips in 31 HIV-positive THA recipients. At this follow-up, 5 patients from the original cohort required contralateral THA. Postoperative complications were recorded up to the patient’s last follow-up date. A survivorship analysis was performed using the Kaplan-Meier method with revision THA as the end point.

Results

Since the last report, 2 additional hips were revised (one for aseptic loosening and one for a periprosthetic fracture), and 5 patients underwent contralateral THA. This resulted in a total of 5 (13.8%) hips requiring revision THA at the latest follow-up. The mean follow-up interval for the original cohort and for the contralateral 5 hips was 78.9 ± 50.2 months and 54.6 ± 45.3 months, respectively. Kaplan-Meier survivorship analysis with revision THA for any reason as the end point demonstrated survivorship of 93% (2 years), 90% (5 years), and 81% (10 and 14 years) after primary THA, respectively.

Conclusion

Our study suggests that it is possible to achieve a low incidence of postoperative infection in HIV-positive THA recipients. In addition, our study demonstrates that non-hemophiliac HIV-positive patients have comparable revision rates to previously published reports on HIV-negative patients of similar age, underscoring the clinical efficacy of highly active antiretroviral therapy.  相似文献   

16.
ABSTRACT Benzoporphyrin derivative monoacid ring A (Verteporfin, BPD-MA), a photosensitizing drug, has been suggested as having inhibitory effects on smooth muscle cell (SMC) proliferation in rabbit aortic intimal injuries. The effect of BPD-MA on vascular SMCs in the absence of light stimulation in vitro and in vivo was studied using models of intimal hyperplasia. Human SMCs were incubated with BPDMA for 4 h in darkness. A small (20%) but significant decrease in viability (n = 42, p &lt; .05) was noted for BPD-MA concentrations above 15 mu g/mL. This was an all-or-none phenomenon with no further decrease in viability at higher concentrations. Treatment with BPD-MA was also carried out in vivo using a balloon injury model of intimal hyperplasia in rabbit aortas. Thirty-three rabbits were randomized into five groups and given intravenous BPD-MA (2 mg/kg) according to the following schedule: Group 1 (n = 8), BPD-MA 25 min prior to injury; Group 2 (n = 8), BPD-MA 25 min prior to injury plus a second dose 4 weeks later; Group 3 (n = 4), BPD-MA immediately postinjury; Group 4 (n = 7), BPD-MA immediately postinjury plus a second dose 4 weeks later; or Group 5 (n = 6), no drug (control group). No statistically significant difference was seen in the amount of intimal hyperplasia that developed in the five groups.  相似文献   

17.
18.
19.
《Transplantation proceedings》2023,55(4):1074-1077
For chronic myeloid leukemia (CML), a Philadelphia chromosome-positive myeloproliferative neoplasm, the introduction of tyrosine kinase inhibitors has transformed CML from a lethal disease into a manageable chronic disease with a close-to-normal life expectancy. Active malignancy is an absolute contraindication to kidney transplantation. However, it is controversial whether kidney transplantation can be safely performed in patients with a history of CML who are in remission. We describe the clinical course of a 64-year-old male patient with chronic kidney disease from diabetic nephropathy (DMN) who underwent living donor kidney transplantation. The patient was diagnosed with CML 15 years ago and promptly achieved cytogenetic and molecular biological remission after starting imatinib. After that, he continued imatinib treatment for 15 years and was in remission, but his chronic kidney disease from DMN gradually worsened. A preemptive living donor kidney transplant was performed in July 2020. Imatinib for CML was discontinued because the patient maintained deep molecular remission (DMR) of major molecular response for more than 15 years before kidney transplantation. After kidney transplantation, the transplanted kidney function remained good at approximate serum creatinine levels of 1.1 mg/dL without histopathologic rejection, and the 3 monthly BCR-ABL1 measurement results were negative and are in progress. Thus, he continues to maintain treatment-free remission status without imatinib for 26 months after renal transplantation. In conclusion, this result suggests that CML with long-lasting DMR on imatinib therapy can be considered an inactive malignancy and therefore a relative indication for kidney transplantation.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号