首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Measurement of viral load in plasma remains the best marker for the follow-up of antiretroviral therapy. However, its use is limited in developing countries due to the lack of adequate facilities and equipment, and cryopreservation of plasma during storage and transportation. Practical and reliable methods adapted to field conditions for the collection, transportation and accurate measurement of HIV-1 viral load are needed for the optimum use of antiretroviral therapy in resource-limited countries. This study evaluated the use of dried blood spots (DBS) for the real-time quantitation of HIV-1 RNA levels with the NucliSENS EasyQ((R)) HIV-1 assay (bioMérieux, Lyon, France) under field conditions in Senegal (Africa). Dried blood spots and plasma from 41 patients living in suburban Dakar were used for determination of HIV-1 RNA concentrations and stability at 37 degrees C. Analysis was performed at the Dakar University Hospital laboratory. Extraction was done with the bioMérieux NucliSENS((R)) miniMAGtrade mark, and real-time detection was done with the bioMérieux NucliSENS((R)) EasyQ system. HIV-1 RNA concentrations in plasma were compared with concentrations in dried blood spots after 8 and 15 days at 37 degrees C. The study showed a strong concordance in RNA levels between plasma and dried blood spots, which appear to be very stable over time with no apparent degradation observed after 2 weeks at 37 degrees C (mean difference 0.065logIU/ml). These results suggest that the use of dried blood spots in combination with the NucliSENS EasyQ HIV-1 assay is well adapted for HIV-1 RNA level monitoring in centralized laboratories in developing countries.  相似文献   

2.
Abbott RealTime HIV-1 Qualitative is an in vitro real-time PCR assay for detecting HIV-1 nucleic acids in human plasma and dried blood spots (DBS). The assay was designed to be used in diagnosis of HIV-1 infections in pediatric and adult patients, with an emphasis on the applicability in resource-limited settings. Use of DBS facilitates specimen collection from remote areas and transportation to testing laboratories. Small sample input requirement facilitates testing of specimens with limited collection volume. The Abbott RealTime HIV-1 Qualitative assay is capable of detecting HIV-1 group M subtypes A-H, group O and group N samples. HIV-1 virus concentrations detected with 95% probability were 80 copies/mL of plasma using the plasma protocol, and 2469 copies/mL of whole blood using the DBS protocol. The assay detected HIV-1 infection in 13 seroconversion panels an average 10.5 days earlier than an HIV-1 antibody test and 4.9 days earlier than a p24 antigen test. For specimens collected from 6 weeks to 18 months old infants born to HIV-1 positive mothers, assay results using both the DBS and plasma protocols agreed well with the Roche Amplicor HIV-1 DNA Test version 1.5 (95.5% agreement for DBS and 97.8% agreement for plasma).  相似文献   

3.
The Nuclisens EasyQ HIV-1 v1.1 assay (Biomerieux) is a real-time detection method combined with NASBA technology designed to measure plasma HIV-RNA. Its performance was assessed in 1008 clinical specimens collected from individuals infected with clade B (774) and non-B (234) HIV-1 variants at four European laboratories. The results were compared with those obtained using three other commercial viral load assays: Cobas Amplicor Monitor HIV-1 v1.5 (Roche), Versant HIV-1 RNA assay (Bayer) and Nuclisens HIV-1 QT (Biomerieux). Overall, the linearity, specificity and reproducibility of the EasyQ assay was comparable with that from the other tests. The correlation coefficient (R) between methodologies was 0.85 for Amplicor; 0.87 for Versant; and 0.91 for Nuclisens. The specificity of the assay was 99.4%. Of note, Versant missed 17% of specimens with non-B subtypes which could be detected by EasyQ, while Amplicor provided similar results than EasyQ. HIV-1 group O specimens were only detected by the EasyQ assay. In conclusion, the performance of the EasyQ assay seems to be similar to that of other HIV-1 viral load tests currently on the market, but it is more sensitive than Versant for HIV-1 non-B subtypes and shows a wider dynamic range than Amplicor. Moreover, as it incorporates the advantage of real-time detection procedures, it facilitates high throughput and short turnaround time.  相似文献   

4.
The usage of dried blood spots as specimens for diagnosis and monitoring of HIV-1 infection in Thailand was evaluated. EDTA blood samples, which were collected from 100 HIV seronegative and 109 HIV seropositive individuals, were tested on dried blood spots; Whatman, Schleicher and Schuell (S&S) No. 903 and S&S IsoCode filter paper. Nucleic acid was extracted and used as a template for HIV-1 proviral DNA detection by an "in-house" multiplex PCR and a commercial Amplicor HIV-1 PCR test (Roche, version 1.0). HIV-1 RNA qualitative (QL) and quantitative (QT) detection was determined by Nucleic Acid Sequence Based Amplification (NASBA). The average DNA per blood spot recovered from Whatman and S&S IsoCode was not statistically different (p = 0.512) with a range of 218.9+/-46.84 and 225.63+/-88.33 microg, respectively. The concordance of HIV-1 proviral DNA detection by PCR from dried blood spots Whatman and S&S IsoCode was 94% versus 89.4% for sensitivity and 100% versus 100% for specificity. The sensitivity and specificity of HIV-1 RNA QL detection in dried blood spots was 89.7 and 97.5%, respectively. The HIV-1 RNA QT from dried blood spots showed a good correlation in paired dried blood spots and plasma with Pearson correlation, r = 0.817 (R2 = 0.667, P < 0.05). The data showed that dried blood spots could be used for the diagnosis and monitoring of HIV-1 infection.  相似文献   

5.
The Amplicor HIV-1 DNA PCR assay (Roche Diagnostics, Branchburg, NJ) requires 500 μl of whole blood for a diagnosis of human immunodeficiency virus type 1 (HIV-1) infection, and this amount is often difficult to obtain from infants. A comparison was performed using 100 and 500 μl of whole blood from infants less than 18 months of age. The concordance rate for HIV DNA PCR-negative and -positive samples was 100% for the two different volumes.  相似文献   

6.
Molecular methods for HIV-1 infection using dried blood-spot (DBS) for HIV-1 CRF01_AE subtypes have not been fully optimized. In this study assays for HIV-1 diagnosis or quantitation were evaluated using infant DBS from Thailand. Paired DBS and whole blood samples from 56 HIV-1 CRF01_AE or B'-infected infants were tested for infant diagnosis using modified Amplicor DNA PCR and NucliSens RNA NASBA and an in-house real-time PCR assay. The Amplicor Monitor viral load (VL) assay, with modifications for DBS, was also evaluated. DBS VL were hematocrit corrected. Stability studies were done on DBS stored at -70 degrees C to 37 degrees C for up to 1 year. The DBS diagnostic assays were 96-100% sensitive and 100% specific for HIV-1 diagnosis. DBS HIV-1 VL were highly correlated with plasma VL when corrected using the actual or an assumed hematocrit factor (r(c)=0.88 or 0.93, respectively). HIV-1 DNA in DBS appeared to be more stable than RNA and could be detected after up to 9 months at most temperatures. DBS VL could be consistently determined when stored frozen. These results show that DBS can be used accurately instead of whole blood for the diagnosis of HIV-1 infection and VL quantitation, particularly if samples are appropriately stored.  相似文献   

7.
BACKGROUND: Monitoring anti-retroviral therapy requires that viral load assays for human immunodeficiency virus type 1 (HIV-1) be applicable to diverse HIV-1 subtypes. OBJECTIVES: To evaluate NucliSens EasyQ HIV-1 assay for quantitation of common HIV-1 subtypes prevalent in South-east Asia. STUDY DESIGN: One hundred and nineteen plasma samples collected in Hong Kong and Cambodia were used to compare the performance of NucliSens EasyQ HIV-1 and COBAS Amplicor HIV-1 Monitor version 1.5 assays. Viral RNA extracted from the NucliSens MiniMAG was also used for HIV-1 subtyping. RESULTS: Performance of NucliSens EasyQ correlated well with COBAS Amplicor (r=0.777, p<0.001) and the small mean difference (0.0462log(10)IU/mL) obtained in the Bland and Altman model indicated good agreement between two assays. The NucliSens EasyQ assay demonstrated a 95% sensitivity at 500IU/mL and 100% specificity. Reproducibility of this assay was within log(10)2-4IU/mL and had a coefficient of variation between 2.3% and 10.4%. Among the 109 specimens included in the analysis, HIV-1 subtyping identified 64 CRF01_AE, 38 subtype B, 3 subtype C, 3 CRF07_BC and 1 subtype G viruses. CONCLUSIONS: Performance of NucliSens EasyQ was comparable to COBAS Amplicor for HIV-1 viral load monitoring. RNA extracts from NucliSens MiniMAG could be used for HIV-1 viral load monitoring, subtyping and drug resistance mutations detection. Our findings highlight the versatility of both NucliSens EasyQ and COBAS Amplicor in monitoring prevalent subtypes and rare circulating recombinant forms (CRFs) in the South-east Asia region.  相似文献   

8.
Effective health care delivery to the majority of perinatally exposed infants worldwide, including those enrolled in prevention of mother-to-child transmission programs, is hampered by lack of access to an HIV diagnosis in infancy. Dried blood spot collection from young infants for centralized HIV polymerase chain reaction (PCR) testing is attainable in low-resource settings, provided PCR methodology suitable for routine laboratory service is available. The accuracy of the Roche Amplicor HIV-1 DNA test version 1.5 (Branchburg, NJ) performed on dried blood spots collected prospectively on ordinary Whatman filter paper from a cohort of 300 6-week-old infants born to HIV-infected women in Johannesburg, South Africa, was assessed. Anonymous analysis of the blood spots using a unique DNA extraction procedure was performed in a routine diagnostic laboratory and the results compared with HIV DNA and RNA PCR liquid blood tests at age 6 weeks, and the HIV status of the infant. Dried blood spots were available for 288 infants (96%) of whom 25 (8.7%) were HIV infected. The Roche Amplicor assay yielded a sensitivity of 100% and a specificity of 99.6%. HIV DNA PCR tests on dried blood spots have the potential to improve health care delivery to HIV-affected children in low-resource settings right now.  相似文献   

9.
In this study, 190 HIV-positive samples were collected from different regions of China. The HIV clades of 153 samples were determined successfully based on env sequencing. Specifically, 48, 5, 87, and 13 isolates belonged to clades B', B, BC, and AE, respectively. The viral loads in all samples were measured using three commercial assays, Amplicor HIV-1 monitor v1.5, Nuclisens HIV-1 QT and NucliSens EasyQ HIV-1 assays. The differences and linear correlations for individual assays were compared, with expected 1:1 relationships. Significant differences were found for the following viral loads: clade BC measured by any two assays (P < 0.001); clade AE between Amplicor 1.5 and Easy Q (P = 0.005); clade B' between Amplicor 1.5 and Nuclisens QT (P = 0.002); clade AE between Amplicor 1.5 and Nuclisens QT (P = 0.025); and clade B' between Amplicor 1.5 and EasyQ (P = 0.04). The largest mean difference in the log(10) values was 0.9518, which was found between Amplicor 1.5 and Nuclisens QT. However, the viral loads for clades AE and B' measured by EasyQ and Nuclisens QT, and those for clade B measured by any two assays did not differ significantly. The degrees of correlation for clades B and B' between any two assays (R > 0.8) were higher that those for clades AE and BC between any two assays (R < 0.7), except for clade AE between Amplicor 1.5 and Easy Q. Thus, the clade types, especially clades BC and AE, are most likely to impact on the quantitation of viral load using differentassays.  相似文献   

10.
In facing global programs for treating HIV-infected patients in the developing countries, there is a real need for viral load assays that are accurate for the local subtypes. The present study was designed to evaluate viral load measurements using the newer version of the NASBA assay in subtype C-infected patients. The performances of this new version, a real-time nucleic acid sequence-based amplification HIV-1 assay (NucliSens EasyQ), were compared to Amplicor HIV-1 Monitor Assay version 1.5 in 79 samples of subtype C-infected patients originating from Ethiopia. Twenty HIV-1 subtype B-infected patients served as a control group. Blood samples from patients in both groups were tested by both assays. The results were compared by a paired, two-tailed Student's t-test. The disparity between the results of the two viral load assays was highly significant in subtype C samples (P = 0.005), such that in the vast majority, higher values of viral load were obtained by the Amplicor assay. However, no differences between the two assays were found in subtype B samples (P = 0.77). CD4 measurements were available for 78 samples of subtype C-infected patients. Of these, a CD4-to-viral load discrepancy (CD4 相似文献   

11.
BACKGROUND: commercial HIV-1 qualitative DNA PCR tests have the potential to detect virus in patients in whom antibody tests may be ineffective, such as patients with primary HIV infection and infants born to HIV seropositive mothers. However, the genetic diversity of HIV-1 raises concern about the ability of the PCR tests to detect all current subtypes. OBJECTIVES: to asses the sensitivity of the Amplicor HIV-1 test on 126 whole-blood samples representing seven different subtypes and to investigate the sensitivity when the standard assay was modified by including the primer pair SK145 and SKCC1B. RESULTS: of the 126 HIV-1 infected persons, 113 were tested positive and 13 were DNA PCR negative. On the basis of these results, the standard Amplicor HIV-1 test had a sensitivity of 90% in our cohort. In addition, 9% of the positive samples showed a low reactivity but above the cut-off of the assay. The standard assay yielded sensitivities of 100% for subtype B (n=16), D (n=9) and G (n=1), but only 83% for subtype A (n=41), 98% for subtype C (n=43), 79% for subtype E (n=14) and 0% for subtype F (n=2). All samples with low reactivity were non-B subtype. Eight of the DNA PCR negative samples, four subtype A, one C and three E were amplified with the modified Amplicor HIV-1 test with addition of SK145/SKCC1B primers. Using this modified protocol, six samples out of eight became positive. However, two samples (one A and one C) remained DNA PCR negative. CONCLUSION: this study confirms that the Amplicor HIV-1 test does not detect all subtypes with equivalent sensitivity and 10% of the samples, tested negative. Thus, it is preferable to add the SK145/SKCC1B primers to the standard test, where infection with non-B subtype is suspected.  相似文献   

12.
13.
Dried blood spots (DBS) can be used in developing countries to alleviate the logistic constraints of using blood plasma specimens for viral load (VL) and HIV drug resistance (HIVDR) testing, but they should be assessed under field conditions. Between 2009 and 2011, we collected paired plasma-DBS samples from treatment-experienced HIV-1-infected adults in Burkina Faso, Cameroon, Senegal, Togo, Thailand, and Vietnam. The DBS were stored at an ambient temperature for 2 to 4 weeks and subsequently at −20°C before testing. VL testing was performed on the plasma samples and DBS using locally available methods: the Abbott m2000rt HIV-1 test, generic G2 real-time PCR, or the NucliSENS EasyQ version 1.2 test. In the case of virological failure (VF), i.e., a plasma VL of ≥1,000 copies/ml, HIVDR genotyping was performed on paired plasma-DBS samples. Overall, we compared 382 plasma-DBS sample pairs for DBS VL testing accuracy. The sensitivities of the different assays in different laboratories for detecting VF using DBS varied from 75% to 100% for the m2000rt test in labs B, C, and D, 91% to 93% for generic G2 real-time PCR in labs A and F, and 85% for the NucliSENS test in lab E. The specificities varied from 82% to 97% for the m2000rt and NucliSENS tests and reached only 60% for the generic G2 test. The NucliSENS test showed good agreement between plasma and DBS VL but underestimated the DBS VL. The lowest agreement was observed for the generic G2 test. Genotyping was successful for 96/124 (77%) DBS tested, and 75/96 (78%) plasma-DBS pairs had identical HIVDR mutations. Significant discrepancies in resistance interpretations were observed in 9 cases, 6 of which were from the same laboratory. DBS can be successfully used as an alternative to blood plasma samples for routine VL and HIVDR monitoring in African and Asian settings. However, the selection of an adequate VL measurement method and the definition of the VF threshold should be considered, and laboratory performance should be monitored.  相似文献   

14.

Background

As antibody testing cannot confirm HIV-1 infection in children less than 18 months of age, diagnosis in these children depends on nucleic acid testing. The COBAS® AmpliPrep/COBAS® TaqMan® (CAP/CTM, Roche® Molecular Systems, Inc., Branchburg, NJ) HIV-1 Qualitative test is a total nucleic acid real-time PCR assay utilising whole EDTA blood or dried blood spots (DBS), which recently replaced the Roche® AMPLICOR® DNA test v1.5 (Amplicor) as the diagnostic HIV PCR assay in many South African laboratories. For the Amplicor assay, stringent diagnostic criteria were previously formulated for the local population, and a comparison reported the CAP/CTM's sensitivity at 99.7% and specificity at 100% for both sample types compared to these Amplicor criteria.

Objectives

To validate the assay prior to introduction in our laboratory and to define stringent diagnostic cut-off criteria.

Study design

Whole EDTA blood samples from patients younger than 18 months sent for routine HIV-1 diagnosis were tested by Amplicor, and positive results were confirmed from DBS. CAP/CTM assays were subsequently performed from DBS.

Results

The CAP/CTM had a sensitivity of 98.8% and a specificity of 97.1%, but a positive predictive value (PPV) of only 78.7% compared to the Amplicor assay. Samples positive by CAP/CTM but negative by Amplicor displayed poor amplification curves compared to concordant positive samples. Upon re-testing those with sufficient material available by CAP/CTM, all showed negative results.

Conclusions

The decreased PPV may either be due to false positive CAP/CTM results, or increased sensitivity compared to the Amplicor assay. Criteria were formulated for defining presumed false-positive results.  相似文献   

15.
Dried blood spots (DBS) on filter paper facilitate the collection, transport, and storage of blood samples for laboratory use. A rapid and simple DNA extraction procedure from DBS was developed and evaluated for the diagnosis of human immunodeficiency virus type 1 (HIV-1) infection in children by an in-house nested-PCR assay on three genome regions and by the Amplicor HIV-1 DNA prototype assay version 1.5 (Roche Molecular Systems). A total of 150 samples from children born to HIV-1-infected mothers were collected in Kigali, Rwanda, in parallel as DBS and as peripheral blood mononuclear cell (PBMC) pellets. The results obtained on DBS by the two PCR assays were compared to the results of nested PCR on PBMCs. Of 150 PBMC samples, 10 were positive, 117 were negative, and 23 were indeterminate for HIV-1 infection. In DNA extracted from filter papers and amplified by using the in-house nested PCR, 9 of these 10 positive samples (90%) were found to be positive, and 1 was found to be indeterminate (only the pol region could be amplified). All of the negative samples and all of the 23 indeterminate samples tested negative for HIV-1 infection. When we used the Amplicor DNA test on DBS, all of the 10 PBMC-positive samples were found to be positive and all of the 23 indeterminate samples were found to be negative. Of the PBMC-negative samples, 115 were found to be negative and 2 were found to be indeterminate. We conclude that this simple rapid DNA extraction method on DBS in combination with both detection methods gave a reliable molecular diagnosis of HIV-1 infection in children born to HIV-infected mothers.  相似文献   

16.
We compared the performance of the NucliSens EasyQ assay (bioMerieux) combined with the manual NucliSens miniMag extraction methodology to the Roche Cobas Ampliprep/Standard Amplicor Monitor methodology (Roche Diagnostics) for HIV-1 RNA quantitation in HIV-1-infected individuals in South Africa. Plasma samples (284) from HIV sero-positive patients at different stages of infection were analyzed. The distribution of results was typical of the clinical samples received at the laboratory where 20% have viral load results <400 copies/ml (2.6 log) and 18% have viral load results >750000 copies/ml (5.8 log) using the Roche Amplicor Monitor standard assay. All statistical analyses were performed using log10-transformed values for all the variables in the analyses, i.e. log10EasyQIU/ml, and log10RNA (log10 copies/ml, Amplicor). Roche values were converted from RNA copies per ml to IU/ml by multiplying the Roche value by 0.51. HIV RNA levels quantitated by the NucliSens EasyQ assay correlated significantly with those of the Roche Cobas Amplicor Monitor assay (r=0.874, p<0.0001). Reproducibility of the NucliSens EasyQ assay in the log6IU range yielded CV variance of 1.3-2.84% for two well-trained technologists. In addition, a retrospective evaluation of the performance of the NucliSens EasyQ assay in 102 runs (2448) samples was conducted in the laboratory over a 4-month interval. Factors considered during this evaluation included time taken to perform the assay, volume requirements, number of required repeats, potential for contamination.  相似文献   

17.
BackgroundHIV-1 RNA plasma level is a key parameter for anti-viral treatment monitoring in HIV-1 infected individuals. Plasma stability and accurate measurement of clinical state is at risk when transporting from remote areas. Dried blood spot (DBS) testing can reduce this risk.ObjectivesDetermine the performance of NucliSENS EasyQ HIV-1 v2.0 for DBS.Study design100 HIV-1 negative, and 129 HIV-1 spiked blood specimens (2180 copies/ml) were used for diagnostic specificity and system robustness. Analytical performance was tested in the range 50–85,000,000 copies/ml. Clinical reactivity was measured with specimens obtained from 224 HIV-1 infected individuals. HIV-1 RNA stability was analyzed after applying several different storage conditions.ResultsDiagnostic specificity was 100% and system robustness was demonstrated by 100% detection rate without invalids. Limit of detection (95% detection rate) was 800 copies/ml. Linear results were obtained over the whole range tested. For clinical specimens, percentage positive results were comparable for DBS (57%) and plasma (58%). DBS quantification was on average 0.36 log 10 lower as compared to plasma. Specimen stability was demonstrated for 1 week at 55 °C/60% humidity, 3 weeks at 37 °C/80% humidity, 9 weeks at 37 °C/40% humidity, 3 months at ?20 °C/70% humidity, 3 weeks at 4 °C/100% humidity, 9 months at room temperature (15–30 °C), and 9 weeks shipment simulation.ConclusionResults obtained fully support the use of DBS for the NucliSENS EasyQ HIV-1 v2.0 assay. These findings are especially of importance in cases that plasma stability is currently at risk due to for example, long transport routes from remote areas under less controlled conditions.  相似文献   

18.
We performed a comparative analysis between Roche Amplicor HIV-1 DNA test and CAPTAQ assay for the detection of HIV in 830 dried blood spot (DBS) pediatric samples collected in Mozambique. Our results demonstrated no statistical difference between these assays. The CAPTAQ assay approached nearly 100% repeatability/accuracy. The increased throughput of testing with minimal operator interference in performing the CAPTAQ assay clearly demonstrated that this method is an improvement over the Roche Amplicor HIV-1 DNA test, version 1.5.  相似文献   

19.
A plasma HIV-1 RNA amplification assay (RNA assay), a quantitative peripheral blood mononuclear cell (PBMC) microculture (culture), and a PBMC HIV-1 DNA amplification assay (DNA assay) were compared for diagnosis of HIV-1 infection in infants receiving zidovudine in Pediatric AIDS Clinical Trials Group protocol 185; assays were performed for all 24 infected and 100 uninfected infants. HIV-1 infection was defined as >or=2 positive cultures or positive antibody to HIV-1 at >or=18 months. Cultures were performed at birth and 6 and 24 weeks of age; DNA and RNA assays were performed on cryopreserved specimens. The sensitivity of culture and DNA and RNA assays at birth was 20.8%, 10.5%, and 26.7%, respectively. At older ages, sensitivity typically exceeded 80%, remaining highest for the RNA assay (>85%). Assay specificity was >99%. Positive predictive values exceeded 93% for each assay at each age; negative predictive values were highest (>90%) for the RNA assay. At birth (P < 0.005) and age 6 weeks (P < 0.001), a significantly larger proportion of infected infants were identified by means of the RNA assay than by the other assays. The diagnostic performance of the RNA assay matched or exceeded that of culture and the DNA assay. Given that RNA assays require less blood volume and yield rapid results, our study adds to existing data suggesting that RNA assays may be used for early diagnosis of HIV-1 infection in infants.  相似文献   

20.

Background

Several commercially available HIV-1 viral load assays based on real-time detection technology and automated platforms are available. It is not clear how the diversity of HIV-1 genotypes impacts the ability to consistently detect HIV-1 viral loads.

Objectives

To examine whether the diversity of HIV-1 genotypes impacts the ability of the Cobas AmpliPrep/Cobas TaqMan HIV-1 test version 2.0 (CAP/CTM v2.0), its version 1.0 (CAP/CTM v1.0) and the NucliSens EasyQ HIV-1 version 2.0 (EasyQ v2.0) assays to consistently determine the viral loads.

Study design

The three assays were used to measure the viral load in 178 plasma samples with diverse genotypes from treatment-naive patients.

Results

CAP/CTM v2.0 showed significant correlation and high agreement with CAP/CTM v1.0 and EasyQ v2.0. CAP/CTM v2.0 showed excellent detection of clade B samples compared with CAP/CTM v1.0 and EasyQ v2.0. However, significant differences were observed when using CAP/CTM v2.0 to test clade BC and AE samples. The HIV-1 load measured by CAP/CTM v2.0 differed by >0.5 log IU/ml in 59.52% and 72.62% of clade BC samples, and in 57.14% and 85.71% of clade AE samples, compared with CAP/CTM v1.0 and EasyQ v2.0, respectively. CAP/CTM v2.0 was more precise (13.18%) than EasyQ v2.0 (29.21%), and both assays showed good linearity (R ≥ 0.9926).

Conclusions

The three assays may not deliver consistent results for samples belonging to clades BC and AE. It is strongly suggested that the version of the HIV-1 viral load assay used initially is also used at follow-up.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号