首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The objective of this paper is to reveal the effectiveness of wavelet based tissue texture analysis for microcalcification detection in digitized mammograms using Extreme Learning Machine (ELM). Microcalcifications are tiny deposits of calcium in the breast tissue which are potential indicators for early detection of breast cancer. The dense nature of the breast tissue and the poor contrast of the mammogram image prohibit the effectiveness in identifying microcalcifications. Hence, a new approach to discriminate the microcalcifications from the normal tissue is done using wavelet features and is compared with different feature vectors extracted using Gray Level Spatial Dependence Matrix (GLSDM) and Gabor filter based techniques. A total of 120 Region of Interests (ROIs) extracted from 55 mammogram images of mini-Mias database, including normal and microcalcification images are used in the current research. The network is trained with the above mentioned features and the results denote that ELM produces relatively better classification accuracy (94%) with a significant reduction in training time than the other artificial neural networks like Bayesnet classifier, Naivebayes classifier, and Support Vector Machine. ELM also avoids problems like local minima, improper learning rate, and over fitting.  相似文献   

2.
Regentova E  Zhang L  Zheng J  Veni G 《Medical physics》2007,34(6):2206-2219
In this paper we investigate the performance of statistical modeling of digital mammograms by means of wavelet domain hidden Markov trees for its inclusion to a computer-aided diagnostic prompting system. The system is designed for detecting clusters of microcalcifications. Their further discrimination as benign or malignant is to be done by radiologists. The model is used for segmenting images based on the maximum likelihood classifier enhanced by the weighting technique. Further classification incorporates spatial filtering for a single microcalcification (MC) and microcalcification cluster (MCC) detection. Contrast filtering applied for the digital database for screening mammography (DDSM) dataset prior to spatial filtering greatly improves the classification accuracy. For all MC clusters of 40 mammograms from the mini-MIAS database of Mammographic Image Analysis Society, 92.5%-100% of true positive cases can be detected under 2-3 false positives per image. For 150 cases of DDSM cases, the designed system is capable to detect up to 98% of true positives under 3.3% of false positive cases.  相似文献   

3.
Recently, the generalized additive models (GAMs) have been presented as a novel statistical approach to distinguish lesion/non-lesion in computer-aided diagnosis (CAD) systems. In this paper, we present an extension of the GAM that allows for the introduction of factors and their interactions with continuous variables, for reducing false positives in a CAD system for detecting clustered microcalcifications in digital mammograms. The results obtained have shown an increase in the sensitivity from 83.12% to 85.71%, while the false positive rate was drastically reduced from 1.46 to 0.74 false detections per image.  相似文献   

4.
In a computer-aided diagnosis (CADx) scheme for evaluating the likelihood of malignancy of clustered microcalcifications on mammograms, it is necessary to segment individual calcifications correctly. The purpose of this study was to develop a computerized segmentation method for individual calcifications with various sizes while maintaining their shapes in the CADx schemes. Our database consisted of 96 magnification mammograms with 96 clustered microcalcifications. In our proposed method, a mammogram image was decomposed into horizontal subimages, vertical subimages, and diagonal subimages for a second difference at scales 1 to 4 by using a filter bank. The enhanced subimages for nodular components (NCs) and the enhanced subimages for both nodular and linear components (NLCs) were obtained from analysis of a Hessian matrix composed of the pixel values in those subimages for the second difference at each scale. At each pixel, eight objective features were given by pixel values in the subimages for NCs at scales 1 to 4 and the subimages for NLCs at scales 1 to 4. An artificial neural network with the eight objective features was employed to enhance calcifications on magnification mammograms. Calcifications were finally segmented by applying a gray-level thresholding technique to the enhanced image for calcifications. With the proposed method, a sensitivity of calcifications within clustered microcalcifications and the number of false positives per image were 96.5% (603/625) and 1.69, respectively. The average shape accuracy for segmented calcifications was also 91.4%. The proposed method with high sensitivity of calcifications while maintaining their shapes would be useful in the CADx schemes.  相似文献   

5.
基于综合处理方法的乳腺X影像中微钙化点检测新技术   总被引:1,自引:0,他引:1  
针对目前乳腺X线影像中微钙化点的计算机辅助检测普遍假阳性较高的难点 ,提出一种能发挥差值、小波及神经网络等多种技术优势的综合处理检测方法。对临床实际病例 (10名患者 ,2 44个微钙化点 )的试用结果表明 ,与单纯使用上述检测技术比较 ,该方法不仅操作简单 ,且具有较高的检出率 (TP达 93 % ) ,同时还明显地降低了假阳性 ,值得深入研究。  相似文献   

6.
We are developing an automated stereo spot mammography technique for improved imaging of suspicious dense regions within digital mammograms. The technique entails the acquisition of a full-field digital mammogram, automated detection of a suspicious dense region within that mammogram by a computer aided detection (CAD) program, and acquisition of a stereo pair of images with automated collimation to the suspicious region. The latter stereo spot image is obtained within seconds of the original full-field mammogram, without releasing the compression paddle. The spot image is viewed on a stereo video display. A critical element of this technique is the automated detection of suspicious regions for spot imaging. We performed an observer study to compare the suspicious regions selected by radiologists with those selected by a CAD program developed at the University of Michigan. True regions of interest (TROIs) were separately determined by one of the radiologists who reviewed the original mammograms, biopsy images, and histology results. We compared the radiologist and computer-selected regions of interest (ROIs) to the TROIs. Both the radiologists and the computer were allowed to select up to 3 regions in each of 200 images (mixture of 100 CC and 100 MLO views). We computed overlap indices (the overlap index is defined as the ratio of the area of intersection to the area of interest) to quantify the agreement between the selected regions in each image. The averages of the largest overlap indices per image for the 5 radiologist-to-computer comparisons were directly related to the average number of regions per image traced by the radiologists (about 50% for 1 region/image, 84% for 2 regions/image and 96% for 3 regions/image). The average of the overlap indices with all of the TROIs was 73% for CAD and 76.8% +/- 10.0% for the radiologists. This study indicates that the CAD determined ROIs could potentially be useful for a screening technique that includes stereo spot mammography imaging.  相似文献   

7.
Wavelet transform (WT) is a potential tool for the detection of microcalcifications, an early sign of breast cancer. This article describes the implementation and evaluates the performance of two novel WT-based schemes for the automatic detection of clustered microcalcifications in digitized mammograms. Employing a one-dimensional WT technique that utilizes the pseudo-periodicity property of image sequences, the proposed algorithms achieve high detection efficiency and low processing memory requirements. The detection is achieved from the parent–child relationship between the zero-crossings [Marr-Hildreth (M-H) detector] /local extrema (Canny detector) of the WT coefficients at different levels of decomposition. The detected pixels are weighted before the inverse transform is computed, and they are segmented by simple global gray level thresholding. Both detectors produce 95% detection sensitivity, even though there are more false positives for the M-H detector. The M-H detector preserves the shape information and provides better detection sensitivity for mammograms containing widely distributed calcifications.Permission has been granted by the Departmental Research Committee, Department of Electronics, Cochin University of Science and Technology, for pursuing research in the field of automated detection of microcalcification in digitized mammograms.  相似文献   

8.
Mammography is the most efficient technique for detecting and diagnosing breast cancer. Clusters of microcalcifications have been mainly targeted as a reliable early sign of breast cancer and their earliest detection is essential to reduce the probability of mortality rate. Since the size of microcalcifications is very tiny and may be overlooked by the observing radiologist, we have developed a Computer Aided Diagnosis system for automatic and accurate cluster detection. A three-phased novel approach is presented in this paper. Firstly, regions of interest that corresponds to microcalcifications are identified. This can be achieved by analyzing the bandpass coefficients of the mammogram image. The suspicious regions are passed to the second phase, in which the nodular structured microcalcifications are detected based on eigenvalues of second order partial derivatives of the image and microcalcification pixels are segmented out by exploiting the foveal segmentation in multiscale analysis. Finally, by combining the responses coming out from the second order partial derivatives and the foveal method, potential microcalcifications are detected. The detection performance of the proposed method has been evaluated by using 370 mammograms. The detection method has a TP ratio of 97.76 % with 0.68 false positives per image. We have examined the performance of our computerized scheme using free-response operating characteristics curve.  相似文献   

9.
A computer-aided diagnosis scheme to assist radiologists in detecting clustered microcalcifications from mammograms is being developed. Starting with a digital mammogram, the scheme consists of three steps. First, the image is filtered so that the signal-to-noise ratio of microcalcifications is increased by suppression of the normal background structure of the breast. Secondly, potential microcalcifications are extracted from the filtered image with a series of three different techniques: a global thresholding based on the grey-level histogram of the full filtered image, an erosion operator for eliminating very small signals, and a local adaptive grey-level thresholding. Thirdly, some false-positive signals are eliminated by means of a texture analysis technique, and a non-linear clustering algorithm is then used for grouping the remaining signals. With this method, the scheme can detect approximately 85% of true clusters, with an average of two false clusters detected per image.  相似文献   

10.
为乳腺癌早期诊断和乳腺X线影像微钙化点计算机辅助检测作前期预处理,提出了一种基于小波变换的微钙化点感兴趣区提取新技术。其具体思路是:(1)将乳腺区域图像提取成等大的子图像;(2 )对每一幅子图像进行小波变换,根据特征参数ρ讨论最优小波变化参数和阈值T;(3)根据阈值T判别子图像是否属于感兴趣区。对临床实际病例(2 0幅乳腺X线影像)的试验结果表明,该方法具有较高的检出率(89.7% ) ,和较为满意的假阳性率(2 .1% )。  相似文献   

11.
Computer aided detection of microcalcifications in digital mammograms   总被引:4,自引:0,他引:4  
Microcalcification detection is widely used for early diagnosis of breast cancer. Nevertheless, mammogram visual analysis is a complex task for expert radiologists. In this paper, we present a new method for computer aided detection of microcalcifications in digital mammograms. The detection is performed on the wavelet transformed image. The calcifications are separated from the background by exploiting the evaluation of Renyi's information at the different decomposition levels of the wavelet transform. Experiments are performed on a standard and publicly available dataset and the results are evaluated with respect to recent achievements reported in the literature.  相似文献   

12.
We have investigated the application of computer-based methods to the detection of microcalcifications in digital mammograms. The computer detection system is based on a difference-image technique in which a signal-suppressed image is subtracted from a signal-enhanced image to remove the structured background in a mammogram. Signal-extraction techniques adapted to the known physical characteristics of microcalcifications are then used to isolate microcalcifications from the remaining noise background. We employ Monte Carlo methods to generate simulated clusters of microcalcifications that are superimposed on normal mammographic backgrounds. This allows quantitative evaluation of detection accuracy of the computer method and the dependence of this accuracy on the physical characteristics of the microcalcifications. Our present computer method can achieve a true-positive cluster detection rate of approximately 80% at a false-positive detection rate of one cluster per image. The potential application of such a computer-aided system to mammographic interpretation is demonstrated by its ability to detect microcalcifications in clinical mammograms.  相似文献   

13.
Mass localization plays a crucial role in computer-aided detection (CAD) systems for the classification of suspicious regions in mammograms. In this article we present a completely automated classification system for the detection of masses in digitized mammographic images. The tool system we discuss consists in three processing levels: (a) Image segmentation for the localization of regions of interest (ROIs). This step relies on an iterative dynamical threshold algorithm able to select iso-intensity closed contours around gray level maxima of the mammogram. (b) ROI characterization by means of textural features computed from the gray tone spatial dependence matrix (GTSDM), containing second-order spatial statistics information on the pixel gray level intensity. As the images under study were recorded in different centers and with different machine settings, eight GTSDM features were selected so as to be invariant under monotonic transformation. In this way, the images do not need to be normalized, as the adopted features depend on the texture only, rather than on the gray tone levels, too. (c) ROI classification by means of a neural network, with supervision provided by the radiologist's diagnosis. The CAD system was evaluated on a large database of 3369 mammographic images [2307 negative, 1062 pathological (or positive), containing at least one confirmed mass, as diagnosed by an expert radiologist]. To assess the performance of the system, receiver operating characteristic (ROC) and free-response ROC analysis were employed. The area under the ROC curve was found to be Az = 0.783 +/- 0.008 for the ROI-based classification. When evaluating the accuracy of the CAD against the radiologist-drawn boundaries, 4.23 false positives per image are found at 80% of mass sensitivity.  相似文献   

14.
We have developed a computer-aided detection (CAD) system to detect clustered microcalcifications automatically on full-field digital mammograms (FFDMs) and a CAD system for screen-film mammograms (SFMs). The two systems used the same computer vision algorithms but their false positive (FP) classifiers were trained separately with sample images of each modality. In this study, we compared the performance of the CAD systems for detection of clustered microcalcifications on pairs of FFDM and SFM obtained from the same patient. For case-based performance evaluation, the FFDM CAD system achieved detection sensitivities of 70%, 80% and 90% at an average FP cluster rate of 0.07, 0.16 and 0.63 per image, compared with an average FP cluster rate of 0.15, 0.38 and 2.02 per image for the SFM CAD system. The difference was statistically significant with the alternative free-response receiver operating characteristic (AFROC) analysis. When evaluated on data sets negative for microcalcification clusters, the average FP cluster rates of the FFDM CAD system were 0.04, 0.11 and 0.33 per image at detection sensitivity level of 70%, 80% and 90% compared with an average FP cluster rate of 0.08, 0.14 and 0.50 per image for the SFM CAD system. When evaluated for malignant cases only, the difference of the performance of the two CAD systems was not statistically significant with AFROC analysis.  相似文献   

15.
Parenchymal patterns characteristic of dense breasts are known to degrade the mammographic detection of small breast cancers and microcalcifications. This arises from large variations in exposure of the film, resulting in reduced image contrast over areas of suboptimal exposure. Based on sensitometric measurements of mammograms from a typical patient population, it is shown that over 60% of a typical mammogram in Wolfe's DY classification was found to be exposed suboptimally, suggesting a significant margin for improving mammography for these patients. In order to address this problem, a prototype mammographic version of scanning equalisation radiography (MSER) has been developed, which delivers a patient-specific spatially non-uniform distribution of breast exposure, adjusted to maintain optimal film exposure and contrast over the entire mammogram. Anthropomorphic phantom MSER images show a marked improvement in subjective image quality relative to conventional mammograms, while exhibiting a similar radiation risk. The detection of small microcalcifications and fibrils over clinically significant breast densities is found to be improved by factors eight and four, respectively. Such a system may be clinically practical through the use of multiple-beam equalisation methods with available X-ray tube technology.  相似文献   

16.
Masotti M 《Medical physics》2006,33(10):3951-3961
Regions of interest (ROIs) found on breast radiographic images are classified as either tumoral mass or normal tissue by means of a support vector machine classifier. Classification features are the coefficients resulting from the specific image representation used to encode each ROI. Pixel and wavelet image representations have already been discussed in one of our previous works. To investigate the possibility of improving classification performances, a novel nonparametric, orientation-selective, and multiresolution image representation is developed and evaluated, namely a ranklet image representation. A dataset consisting of 1000 ROIs representing biopsy-proven tumoral masses (either benign or malignant) and 5000 ROIs representing normal breast tissue is used. ROIs are extracted from the digital database for screening mammography collected by the University of South Florida. Classification performances are evaluated using the area Az under the receiver operating characteristic curve. By achieving Az values of 0.978 +/- 0.003 and 90% sensitivity with a false positive fraction value of 4.5%, experiments demonstrate classification results higher than those reached by the previous image representations. In particular, the improvement on the Az value over that achieved by the wavelet image representation is statistically relevant with the two-tailed p value <0.0001. Besides, owing to the tolerance that the ranklet image representation reveals to variations in the ROIs' gray-level intensity histogram, this approach discloses to be robust also when tested on radiographic images having gray-level intensity histogram remarkably different from that used for training.  相似文献   

17.
Architectural distortion is an important sign of breast cancer, but because of its subtlety, it is a common cause of false-negative findings on screening mammograms. This paper presents methods for the detection of architectural distortion in mammograms of interval cancer cases taken prior to the detection of breast cancer using Gabor filters, phase portrait analysis, fractal analysis, and texture analysis. The methods were used to detect initial candidates for sites of architectural distortion in prior mammograms of interval cancer and also normal control cases. A total of 4,224 regions of interest (ROIs) were automatically obtained from 106 prior mammograms of 56 interval cancer cases, including 301 ROIs related to architectural distortion, and from 52 prior mammograms of 13 normal cases. For each ROI, the fractal dimension and Haralick’s texture features were computed. Feature selection was performed separately using stepwise logistic regression and stepwise regression. The best results achieved, in terms of the area under the receiver operating characteristics curve, with the features selected by stepwise logistic regression are 0.76 with the Bayesian classifier, 0.73 with Fisher linear discriminant analysis, 0.77 with an artificial neural network based on radial basis functions, and 0.77 with a support vector machine. Analysis of the performance of the methods with free-response receiver operating characteristics indicated a sensitivity of 0.80 at 7.6 false positives per image. The methods have good potential in detecting architectural distortion in mammograms of interval cancer cases.  相似文献   

18.
In this paper, a novel fast method for modeling mammograms by deterministic fractal coding approach to detect the presence of microcalcifications, which are early signs of breast cancer, is presented. The modeled mammogram obtained using fractal encoding method is visually similar to the original image containing microcalcifications, and therefore, when it is taken out from the original mammogram, the presence of microcalcifications can be enhanced. The limitation of fractal image modeling is the tremendous time required for encoding. In the present work, instead of searching for a matching domain in the entire domain pool of the image, three methods based on mean and variance, dynamic range of the image blocks, and mass center features are used. This reduced the encoding time by a factor of 3, 89, and 13, respectively, in the three methods with respect to the conventional fractal image coding method with quad tree partitioning. The mammograms obtained from The Mammographic Image Analysis Society database (ground truth available) gave a total detection score of 87.6%, 87.6%, 90.5%, and 87.6%, for the conventional and the proposed three methods, respectively.  相似文献   

19.
This work proposes a method aimed at enhancing the contrast in dense breast images in mammography. It includes a new preprocessing technique, which uses information on the modulation transfer function (MTF) of the mammographic system in the whole radiation field. The method is applied to improve the efficiency of a computer-aided diagnosis (CAD) scheme. Seventy-five regions of interest (ROIs) from dense mammograms were acquired in two pieces of equipment (a CGR Senographe 500t and a Philips Mammodiagnost) and were digitized in a Lumiscan 50 laser scanner. A computational procedure determines the effective focal spot size in each region of interest from the measured focal spot in the center for a given mammographic equipment. Using computational simulation the MTF is then calculated for each field region. A procedure that enlarges the high-frequency portion of this function is applied and a convolution between the resulting new function and the original image is performed. Both original and enhanced images were submitted to a processing procedure for detecting clustered microcalcifications in order to compare the performance for dense breast images. ROIs were divided into four groups, two for each piece of equipment-one with clustered microcalcifications and another without microcalcifications. Our results show that in about 10% of the enhanced images more signals were detected when compared to the results for the original dense breast images. This is important because the usual processing techniques used in CAD schemes present poor results when applied to dense breast images. Since the MTF method is a well-recognized tool in the evaluation of radiographic systems, this new technique could be used to associate quality assurance procedures with the processing schemes employed in CAD for mammography.  相似文献   

20.
Segmentation of suspicious clustered microcalcifications in mammograms   总被引:3,自引:0,他引:3  
We have developed a multistage computer-aided diagnosis (CAD) scheme for the automated segmentation of suspicious microcalcification clusters in digital mammograms. The scheme consisted of three main processing steps. First, the breast region was segmented and its high-frequency content was enhanced using unsharp masking. In the second step, individual microcalcifications were segmented using local histogram analysis on overlapping subimages. For this step, eight histogram features were extracted for each subimage and were used as input to a fuzzy rule-based classifier that identified subimages containing microcalcifications and assigned the appropriate thresholds to segment any microcalcifications within them. The final step clustered the segmented microcalcifications and extracted the following features for each cluster: the number of microcalcifications, the average distance between microcalcifications, and the average number of times pixels in the cluster were segmented in the second step. Fuzzy logic rules incorporating the cluster features were designed to remove nonsuspicious clusters, defined as those with typically benign characteristics. A database of 98 images, with 48 images containing one or more microcalcification clusters, provided training and testing sets to optimize the parameters and evaluate the CAD scheme, respectively. The results showed a true positive rate of 93.2% and an average of 0.73 false positive clusters per image. A comparison of our results with other reported segmentation results on the same database showed comparable sensitivity and at the same time an improved false positive rate. The performance of the CAD scheme is encouraging for its use as an automatic tool for efficient and accurate diagnosis of breast cancer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号