首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
The purpose of this study was to compare the clinical outcome, union rate, and complications of a consecutive series of Scaphoid excision and limited wrist arthrodesis performed by a single surgeon using distal radius bone graft and K-wires or circular plate fixation. A sequential series of ten patients(11 wrists) who were stabilized with temporary K-wires were compared to 11 patients (11 wrists) who were stabilized with a circular plate. Minimum follow-up was 1 year. One patient in the K-wire group was converted to a wrist fusion. Six of the remaining ten patients in the K-wire fixation group and 8 of the 11 patients in the circular plate fixation group returned for the following blinded evaluations: Quick DASH, analog pain scale, range of motion, grip and pinch strength, plain x-ray, and multi-detector computed tomography evaluation. One non-union occurred in the K-wire group. There were no non-unions in the circular plate fixation group. There was no difference in any of remaining measures or rate of complications. This study shows that equivalent results can be obtained using circular plate fixation compared to K-wires when equivalent bone graft source and fusion technique are used. If K-wire removal requires a return to the OR, circular plate fixation is more cost-effective.  相似文献   

4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
Ligamentous wrist injuries are common occurrences that require complex anatomical mastery and extensive understanding of diagnostic and treatment modalities. The purpose of this educational review article is to delve into the most clinically relevant wrist ligaments in an organized manner to provide the reader with an overview of relevant anatomy, function, clinical examination findings, imaging modalities, and options for management. Emphasis is placed on elucidating reported diagnostic accuracies and treatment outcomes to encourage evidence-based practice.  相似文献   

16.
17.
18.
Reproduction of healthy wrist biomechanics should minimize the abnormal joint forces that could potentially result in the failure of a total wrist arthroplasty (TWA). To date, the in vivo kinematics of TWA have not been measured and it is unknown if TWA preserves healthy wrist kinematics. Therefore, the purpose of this in vivo study was to determine the center of rotation (COR) for a current TWA design and to compare its location to the healthy wrist. The wrist COR for six patients with TWA and 10 healthy subjects were calculated using biplane videoradiography as the subjects performed various range-of-motion and functional tasks that included coupled wrist motions. An open-source registration software, Autoscoper, was used for model-based tracking and kinematics analysis. It was demonstrated that the COR was located near the centers of curvatures of the carpal component for the anatomical motions of flexion-extension and radial-ulnar deviation. When compared to healthy wrists, the COR of TWAs was located more distal in both pure radial deviation (P < .0001) and pure ulnar deviation (P = .07), while there was no difference in its location in pure flexion or extension (P = .99). Across all coupled motions, the TWA's COR shifted more than two times that of the healthy wrists in the proximal-distal direction (17.1 vs 7.2 mm). We postulate that the mismatch in the COR location and behavior may be associated with increased loading of the TWA components, leading to an increase in the risk of component and/or interface failure.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号