首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Arthroscopy》2023,39(2):142-144
Tears of the quadriceps or patellar tendon usually occur after a sudden eabccentric contraction and are diagnosed by a palpable gap at the injury site combined with an inability to perform a straight leg raise. Bilateral knee radiographs may demonstrate patella alta with patellar tendon tears and patella baja with quadriceps tendon tears compared with the uninjured knee. Ultrasound and magnetic resonance imaging can be helpful when there is uncertainty in the diagnosis. Surgical treatment is indicated for complete tears and some high-grade, partial tears. Nonabsorbable high-strength sutures or suture tape are placed in running locking fashion along the injured tendon and secured to the patella with bone tunnels (i.e., transosseous) or suture anchors. The transosseous technique requires exposure of the length of the patella to drill 3 bone tunnels to shuttle the sutures and tie over either pole of the patella. The suture anchor technique allows for a smaller incision and less soft-tissue dissection and may use a knotted or knotless technique. Biomechanical testing with load to failure is not statistically different between the transosseous and anchor techniques, although anchors have been shown to have less gap formation at the repair site. Repair augmentation with a graft may be beneficial in mid-substance injuries, chronic tears, and in cases of compromised tissue quality. Rehabilitation usually can be initiated immediately with protected weight-bearing in an orthosis, safe-zone knee passive range of motion, and avoidance of active extension. After a period of 6 weeks, rehabilitation can progress with full range of motion and a concentric strengthening program.  相似文献   

2.
《Arthroscopy》2003,19(6):572-576
Purpose:The goal of the study was to compare the primary fixation strength of transosseous suture, suture anchor, and hybrid repair techniques for rotator cuff repair.Type of Study:Animal model experiment.Methods:Thirty-two sheep shoulders were divided into 4 homogeneous groups, according to bone density and tendon dimensions. Infraspinatus tendons were transected from their insertions and reattached using 4 different techniques. Group 1 was repaired with a single Mason-Allen stitch and 2 transosseous tunnels for each end of the suture, knotted on the lateral cortex of proximal humerus; group 2 was repaired with double Mason-Allen stitches and 2 transosseous tunnels; group 3 was repaired with 2 Corkscrews (Arthrex, Germany); and group 4 was repaired with 2 Corkscrews combined with a single Mason-Allen transosseous suture. All specimens were tested for their fixation strengths with a material testing system.Results:The mode of failure in group 1 was mainly suture breakage. In groups 3 and 4, the tendons pulled out from the sutures. In group 2, sutures broke the bony bridge between the 2 tunnels. The mean load to failure value was 160.31 ± 34.59 N in group 1, 199.36 ± 11.73 N in group 2, 108.32 ± 15.98 N in group 3, and 214.24 ± 28.52 N in group 4. Anchor fixation was significantly weaker compared with other groups (P <.001). Combination of a transosseous suture and anchor fixation (group 4) was significantly stronger than the single transosseous suture (group 1) and double anchor techniques (group 3) (P <.001).Conclusions:Hybrid technique was the strongest among the tested rotator cuff repair techniques. With the addition of one transosseous suture to two anchors, the strength of the repair could be doubled.  相似文献   

3.
《Arthroscopy》2023,39(6):1490-1492
Quadriceps tendon suture anchor repair provides biomechanically greater and more consistent failure loads than transosseous tunnel repair, including less cyclic displacement (gap formation). Although satisfactory clinical outcomes are found with both repair techniques, few studies provide a side-to-side comparison. However, recent research demonstrates better clinical outcomes in using suture anchors, with equal failure rates. Suture anchor repair is minimally invasive requiring smaller incisions, less patellar dissection, and eliminates patellar tunnel drilling that can breach the anterior cortex, create stress risers, result in osteolysis from nonabsorbable intraosseous sutures and longitudinal patellar fractures. Suture anchor quadriceps tendon repair should now be considered the gold standard.  相似文献   

4.
Transosseous patellar tunnels commonly are used in the repair of acute or chronic patellar tendon or quadriceps tendon ruptures. Commonly, a small diameter (2.0-3.5 mm) drill bit is used to create these drill tunnels. However, drill bits are relatively brittle and susceptible to breakage. The use of a larger diameter smooth Steinmann pin (3/32") is recommended to create transosseous patellar tunnels to eliminate this potential complication.  相似文献   

5.
Introduction:Rupture of the pectoralis major (PM) tendon was initially described almost 2 centuries ago, but most of the reported injuries have occurred within the last 30 years. Options for repair have varied widely. The most common methods for repair depend on either transosseous sutures or suture anchors for fixation. Transosseous suture repair allows for docking the tendon into a trough at its anatomic insertion, but risks cortical breakage during suture passing. Our experience has confirmed the value and potential advantages of anchors for a secure fixation.Aims:To describe a variation of repair using knotless suture anchors and a burred trough to dock the tendon into its anatomic insertion.Conclusion:We describe a technique of a transosseous equivalent PM repair technique. To our knowledge, this is the first paper describing such a repair technique for PM rupture.  相似文献   

6.
Previous experimental studies of failure of rotator cuff repair have involved single pull to ultimate load. Such an experimental design does not represent the cyclic loading conditions experienced in vivo. We created 1 ×2 cm rotator cuff defects in 16 cadaver shoulders, repaired each defect with three MitekRC suture anchors (Mitek Surgical Products, Inc, Westwood, MA) using simple sutures of No. 2 Ethibond, and cyclically loaded the repairs by a servohydraulic materials test system actuator at physiological rates and loads (rate of 33 mm/s, load 180 N). A progressive gap was noted in each specimen, for a 100% rate of failure of the repairs. The central suture always failed first and by the largest magnitude, confirming tension overload centrally. One specimen exhibited combined bone and tendon failure, but the other 15 specimens failed through the tendon. Overall, the repairs failed to 5 mm and 10 mm at an average of 61 cycles and 285 cycles, respectively. Half the specimens were less than 45 years of age and had a 5-mm and 10-mm failure at an average of 107 and 478 cycles, respectively. The other half were over 45 years of age and failed to 5 mm and 10 mm at an average of 17 and 91 cycles, respectively, indicating more rapid failure of the rotator cuff tendons in the older group, and this was statistically significant (P ≤ .02). Comparison of suture anchor fixation in this study with transosseous bone tunnel fixation in a previous cyclic loading study at this institution indicates that bone fixation by suture anchors is significantly less prone to failure than bone fixation through bone tunnels (P = .0008). Changing the bone fixation from bone tunnels to suture anchors effectively transferred the weak link from bone to tendon.  相似文献   

7.
《Injury》2021,52(3):339-344
IntroductionTwo major techniques are used to repair complete quadriceps tendon ruptures, transosseous tunnel (TT) and the suture anchor (SA). There are multiple studies comparing the biomechanical outcomes of repairs performed with TT or SA. Our purpose was to compare the clinical outcomes following quadriceps tendon repair using SA and TT fixation techniques.MethodsThree major search engines were used with predetermined keyword searches to perform a systematic review of literature. These studies were independently scanned by two reviewers using PRISMA criterion. All included studies had to include at least one of the following outcome measures: range of motion (ROM), Lysholm score, complications, and/or re-ruptures.ResultsUsing three major search engines, 1039 articles were identified. After removing duplicates and screening for inclusion, 49 articles were reviewed. Two independent reviewers searched the studies to meet the inclusion criteria, and eight studies were selected. These eight studies included 156 knees in the TT group and 54 knees in the SA group. The TT group had a significantly better ROM after QT repair (132.5° versus 127.0°, p = 0.02). There was no significant difference in Lysholm scores between the TT group (92.6) and SA group (91.0, p = 0.11). There were significantly more complications in SA groups (9.3% versus 1.3%, p = 0.013), but not a significant difference in re-rupture rate between those undergoing SA vs. TT repair (3.7% versus 0%, p = 0.065). The SA group had a significantly higher age at time of surgery (63.62 vs. 54.32)ConclusionThe current study suggests that, following quadriceps tendon rupture, there are no significant differences in functional outcome between TT and SA techniques. Those undergoing TT repair attained a statistically significantly greater final ROM but this difference may not be clinically relevant. There was a statistically significantly higher rate of post-operative complications using SA technique.  相似文献   

8.
Quadriceps tendon rupture is an incapacitating injury that usually requires surgical repair. Traditional repair methods involve transpatellar suture tunnels, but recent reports have introduced the idea of using suture anchors to repair the ruptured tendon. We present 5 cases of our technique of using suture anchors to repair the ruptured quadriceps tendon.  相似文献   

9.
Grim C  Lorbach O  Engelhardt M 《Der Orthop?de》2010,39(12):1127-1134
Ruptures of the quadriceps or patellar tendon are uncommon but extremely relevant injuries. Early diagnosis and surgical treatment with a stable suture construction are mandatory for a good postoperative clinical outcome. The standard methods of repair for quadriceps and patellar tendon injuries include the placement of suture loops through transpatellar tunnels. Reinforcement with either a wire cerclage or a PDS cord is used in patellar tendon repair. The PDS cord can also be applied as augmentation in quadriceps tendon repair. In secondary patellar tendon repair an autologous semitendinosus graft can be used. For chronic quadriceps tendon defects a V-shaped tendon flap with a distal footing is recommended. The different methods of repair should lead to early functional postoperative treatment. The clinical outcome after surgical treatment of patellar and quadriceps tendon ruptures is mainly good.  相似文献   

10.
Rupture of the insertion of the pectoralis major muscle to the proximal humerus is becoming a common injury. Repair of these ruptures increases patient satisfaction, strength, and cosmesis, and shortens return to competitive sports. Several repair techniques have been described, but recently many surgeons are using suture anchors. The traditional repair technique uses transosseous sutures, but no study has biomechanically compared the strength of these two repair techniques in human cadavers. Twelve fresh‐frozen human shoulder specimens were dissected. The pectoralis major tendon insertion was cut from the bone and repaired using one of the two repair techniques: specimens were randomly assigned to transosseous trough with suture tied over bone versus four suture anchors. The fixation constructs were pulled to failure at 4 mm/s on a materials testing system. The mean ultimate failure load of the transosseous repairs was 611 N and the mean ultimate failure load of the suture anchor repair was 620 N. The mean stiffness of the transosseous repair was 32 and 28 N/mm for the suture anchor group. We found no statistically significant difference between these two repair techniques. © 2011 Orthopaedic Research Society Published by Wiley Periodicals, Inc. J Orthop Res 29:1783–1787, 2011  相似文献   

11.
Repair of a ruptured patellar tendon is usually performed with the use of sutures that are passed through intraosseous tunnels within the patella. However, a number of caveats pertain to this method. The Beath pin may penetrate the articular surface or may unduly injure the quadriceps through multiple passes. The already injured patellar tendon may be overly shortened after debridement and insertion into bony tunnels, and loosening through the tunnels may occur. Obliquely oriented bony tunnels may cause abnormal patellar tilt, leading to uneven force distribution. This technical note reports the details of an alternative repair with 3 suture anchors that is incorporated into a 6-stranded Krackow technique, with additional mattress sutures as needed. Because of the low-profile nature of the anchors, this technique more accurately re-creates the footprint at the inferior pole of the patella and avoids articular cartilage penetration and injury to the surrounding soft tissue. The possibility of loosening through bony tunnels or creation of abnormal stresses is eliminated. A smaller incision is used, and operative (tourniquet) time is diminished. Although pullout of the anchors may be a logical concern, previous studies have suggested that this construct is more than sufficient to withstand the forces to which it is subjected.  相似文献   

12.
《Arthroscopy》2001,17(4):360-364
Purpose: The purposes of the study were (1) to compare rotator cuff repair strengths after cyclic loading of 2 bioabsorbable nonsuture-based tack-type anchors, transosseous sutures, and a metal suture-based anchor, and (2) to correlate bone mineral density with mode of failure and cycles to failure. We hypothesized that specimens with a lower bone density would fail through bone at a lower number of cycles independent of the method of cuff fixation. Type of Study: Ex vivo biomechanical study. Methods: Standardized full-thickness rotator cuff defects were created in 30 fresh-frozen cadaveric shoulders that were randomized to 1 of 4 repair groups: transosseous sutures; Mitek Super suture anchors (Mitek Surgical Products, Westwood, MA); smooth bioabsorbable 8-mm Suretacs (Acufex, Smith & Nephew Endoscopy, Mansfield, MA); or spiked bioabsorbable 8-mm Suretacs (Acufex). All repairs were cyclically loaded from 10 to 180 N; the numbers of cycles to 50% (gap, 5 mm) and 100% (gap, 10 mm) failure were recorded. Results: In comparing the repair groups, we found only 1 significant difference: the number of cycles to 100% failure was significantly higher (P <.05) for the smooth bioabsorbable tack than for the transosseous suture group. There were no statistically significant (P ≤.05) differences in bone mineral densities with regard to each specimen’s mode of failure. Conclusions: Our results suggested that immediate postoperative fixation provided by bioabsorbable tacks was similar to that provided by Mitek anchors and more stable than that provided by transosseous sutures. Therefore, the immediate postoperative biomechanical strength of bioabsorbable tacks seems comparatively adequate for fixation of selected small rotator cuff tears. However, additional evaluation in an animal model to examine degradation characteristics and sustained strength of repair is recommended before clinical use.Arthroscopy: The Journal of Arthroscopic and Related Surgery, Vol 17, No 4 (April), 2001: pp 360–364  相似文献   

13.
The aim of this biomechanical study was to evaluate rotator cuff repair strength using different suture anchor techniques compared to conventional repair, taking into consideration the native strength of the supraspinatus tendon. Therefore, a defined defect of the supraspinatus was created in 50 freshly frozen cadaver specimen (group size n = 10; median age at death: 56 years). Five methods were employed for cuff repair: standard transosseous suture, modified transosseous suture with patch augmentation and three suture anchors (Acufex Wedge TAG, Acufex Rod TAG und Mitek GII). The maximum tensile load of the five techniques was: standard transosseous suture, 410 N; modified transosseous suture, 552 N; Wedge TAG, 207 N; Rod TAG, 217 N; Mitek GII, 186 N. The difference between the suture anchor and standard techniques were highly significant (P < 0.001). In this series, the Mitek Gll anchor showed the lowest anchor dislocation rate at 3% (n = 1). The Wedge TAG system had a dislocation rate of 27% (n = 8) and the Rod TAG system 43% (n = 13). Suture anchor techniques revealed about 20%, the standard technique 34% and its modification 60% of the hypothetically calculated native tendon strength. Compared to conventional transosseous suture techniques, the use of the suture anchors tested in this series does not significantly increase the primary fixation strength of rotator cuff repair. The metallic implant with two barbs (Mitek GII) seems to be superior to the polyacetal anchors when inserted into the spongiform bone of the greater tubercle. The considerably weaker repair strength needs to be taken into consideration in postoperative patient rehabilitation, especially after the use of suture anchors.  相似文献   

14.
BackgroundThe aim of this study is to compare two types of suture bridging constructs; a laterally based bridging single row (SR) construct and a classic dual row (DR) suture bridge construct. The hypothesis is that the DR construct will demonstrate superior biomechanical properties.MethodsSix matched pairs of sheep infraspinatus tendon tears repaired with these two different types of suture bridging techniques were tested for gap formation, ultimate failure load and mode of failure. The specimens were pre-cycled for 10 cycles before they were subjected to a constant pre-load of 10N. The specimens were then subjected to cyclic loading at a speed of 8.33 mm/s. The test was stopped after every 500 cycles for a total of 3000 cycles.ResultsMean gap formation after 3000 cycles was lower in the DR group (0.81 ± 0.2 mm versus 2.44 ± 0.27 mm; p = 0.002). Mean change in gap (with every 500 cycles) was also lesser for the DR group after 1500 cycles. DR repairs failed at a higher load (523.4 ± 80.4 N) compared to the SR repairs (452.3 ± 66.3 N) but this did not reach significance. All repairs failed with sutures pulling through the tendon during load to failure testing.ConclusionsGap formation is significantly lower with a dual row suture bridge construct than a laterally based bridging single row construct.Level of evidenceBiomechanical study.  相似文献   

15.
BackgroundLateral ankle ligament repairs increasingly use suture anchors instead of bone tunnels. Our purpose was to compare the biomechanical properties of a knotted and knotless suture anchor appropriate for a lateral ankle ligament reconstruction.MethodsIn porcine distal fibulae, 10 samples of 2 different PEEK anchors were inserted. The attached sutures were cyclically loaded between 10 N and 60 N for 200 cycles. A destructive pull was performed and failure loads, cyclic displacement, stiffness, and failure mode recorded.ResultsPushLock 2.5 anchors failed before 200 cycles. PushLock 100 cycle displacement was less than Morphix 2.5 displacement (p < 0.001). Ultimate failure load for anchors completing 200 cycles was 86.5 N (PushLock) and 252.1 N (Morphix) (p < 0.05). The failure mode was suture breaking for all PushLocks while the Morphix failed equally by anchor breaking and suture breakage.ConclusionsThe knotted Morphix demonstrated more displacement and greater failure strength than the knotless PushLock. The PushLock failed consistently with suture breaking. The Morphix anchor failed both by anchor breaking and by suture breaking.  相似文献   

16.
Operative fixation is the treatment of choice for a rupture of the distal tendon of biceps. A variety of techniques have been described including transosseous sutures and suture anchors. The poor quality of the bone of the radial tuberosity might affect the load to failure of the tendon repair in early rehabilitation. The aim of this study was to determine the loads to failure of different techniques of fixation and to investigate their association with the bone mineral density of the radial tuberosity. Peripheral quantitative computed tomography was carried out to measure the trabecular and cortical bone mineral density of the radial tuberosity in 40 cadaver specimens. The loads to failure in four different techniques of fixation were determined. The Endobutton-based method showed the highest failure load at 270 N (sd 22) (p < 0.05). The mean failure load of the transosseous suture technique was 210 N (sd 66) and that of the TwinFix-QuickT 5.0 mm was 57 N (sd 22), significantly lower than those of all other repairs (p < 0.05). No significant correlation was seen between bone mineral density and loads to failure. The transosseous technique is an easy and cost-saving procedure for fixation of the distal biceps tendon. TwinFix-QuickT 5.0 mm had significantly lower failure loads, which might affect early rehabilitation, particularly in older patients.  相似文献   

17.
Acute isolated rupture of the patellar tendon traditionally has been repaired via transpatellar suture tunnels. This retrospective study evaluated the demographics and epidemiology of this injury as well as the effectiveness and complication rates of our suture anchor technique. Between 1993 and 2005, a total of 82 cases of patellar tendon disruption in 71 patients were repaired. Fourteen cases involved basic primary repair with suture anchors of an acute isolated rupture of the patellar tendon and had an average follow-up of 29 months (range: 3-112 months). There were 3 (21%) failures of repair. The remaining 11 patients had excellent range of motion and strength and returned to their preoperative level of function. These results are comparable with other reports in the literature. The suture anchor technique thus represents a viable option for repair of patellar tendon ruptures and should be investigated further with a randomized, controlled trial.  相似文献   

18.
BackgroundPolyetheretherketone (PEEK) suture anchors are frequently used in Bankart shoulder stabilisation. This study analyzed the primary stability and revisability of PEEK anchors in-vitro in case of primary Bankart repair and revision Bankart repair after failed primary repair.MethodsTo simulate primary Bankart repair, 12 anchors (Arthrex PEEK PushLock® 3.5 mm) were implanted in 1, 3, 5, 7, 9 and 11 o'clock positions in cadaveric human glenoids and then cyclically tested. To simulate revision Bankart repair, 12 anchors were implanted in the same manner, over-drilled and 12 new anchors of the same diameter were implanted into the same bone socket as the primary anchors and then cyclically tested. The maximum failure loads (Fmax), system displacements, force at clinical failure and modes of failure were recorded.ResultsOne primary anchor failed prematurely due to a technical problem. Three out of 12 revision anchors (25%) dislocated while setting the 25 N preload. The Fmax, the displacement and clinical failure of the remaining 9 revision anchors were non-significant when compared to the 11 primary repair anchors. The main mode of failure in the primary and revision Bankart surgery group was suture slippage. Anchor dislocations were observed four times in the primary and once in the revision repair groups.ConclusionsRevision Bankart repair using PEEK anchors of the same diameter in a pre-existing bone socket is possible but bears high risk of premature anchor failure and can jeopardize the reconstruction. PEEK suture anchor in revision Bankart surgery should be implanted in a new bone socket if possible.  相似文献   

19.
Ruptures of the quadriceps as well as the patellar tendon occur in low frequency, but cause major functional deficits of the leg. These injuries usually require operative treatment. Acute quadriceps tendon ruptures are treated by suture repair, using heavy sutures guided through bone tunnels in the patella. Chronic defects and neglected cases require a local tendon transfer, either by a quadriceps tendon turn-down or by a V-Y-plasty of the quadriceps tendon. Ruptures of the patellar tendon are treated by suture of the tendon stumps plus an reinforcement procedure protecting the tendon and avoiding secondary patella alta. Patello-tibial fixation may be achieved by a cerclage technique using wire or an autologous tendon strip, alternatively a patello-tibial external fixator can be applied. In chronic and neglected cases, patellar tendon reconstruction is performed with autologous tendon grafts or with soft tissue allografts. The graft must be protected by a patello-tibial fixation for the first weeks.  相似文献   

20.
《The Journal of arthroplasty》2019,34(6):1279-1286
BackgroundPatellar or quadriceps tendon ruptures after total knee arthroplasty constitute a devastating complication with historically poor outcomes. With advances in soft tissue reconstruction and repair techniques, treatment has become more nuanced. Numerous graft options for reconstruction and suture techniques for repair have been described but there is no consensus regarding optimal treatment.MethodsA search of PubMed, MEDLINE, Embase, and Scopus was conducted. Articles meeting inclusion criteria were reviewed. Type of intervention performed, type of injury studied, outcome measures, and complications were recorded. Quantitative and qualitative analyses were performed.ResultsTwenty-eight articles met inclusion criteria. The complication rate after repair of patellar tendon (63.16%) was higher than the complication rate after repair of quadriceps tendon (25.37%). However, the complication rate for patellar and quadriceps tendon tears after autograft, allograft, or mesh reconstruction was similar (18.8% vs 19.2%, respectively). The most common complication after extensor mechanism repair or reconstruction was extension lag of 30° or greater (45.33%). This was followed by re-rupture and infection (25.33% and 22.67%, respectively). Early ruptures had a higher overall complication rate than late injuries.ConclusionExtensor mechanism disruption after total knee arthroplasty is a complication with high morbidity. Reconstruction of patellar tendon rupture has a much lower complication rate than repair. Our findings support the recommendation of patellar tendon reconstruction in both the early and late presentation stages. Quadriceps rupture can be treated with repair in early ruptures or with reconstruction in the late rupture or in the case of revision surgery.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号